2800 Tatabánya - Hungary Cseresznyefa u. 60/3 Tel/Fax: 06/34 300-142 Mobil 1: 06/30 216-4583 E-mail: [email protected] Audit and measuring Date: ESD audit and measuring report Qualifier sheet 03.03.2014 Protocol No.: MUF_07_05_01D-5 Revízió: 05 Kiadás dátuma: 2013.10.01. 20140303-1ESD_Dr. Schutz_eng Place of inspection: GOD-MIN Mérnöki Kft. – GOD-MON LABORATORY - Tatabánya Godó Attila / ESD expert – Drágán Tamás / ESD technician Measuring place: Measured by: Description of the product: Product description: Manufacturer (supplier) data: ESD Longlife PU Sealer (transparent or colored type) Dr. Schutz – Germany (Hungary – Örkönd Kft.) Mérési körülmények: Measuring Standards: ESD requirements: MSZ EN 61340-5-1, ANSI/ESD S20.20 (IEC 61340-4-1,4-5, ANSI S7.1, STM97.1) Resistance: Rg<109 Ω, Rsys<35x106 Ω or <1x109, Rpp<109 Ω, Ug walking<100 V Check voltage: R<1x105 Ω→10V; R>1x105 Ω→100V Measuring enviroment: Normal Temperature: 23,1 oC Relativ Humidity: 53 % RH Temperature: Pump out of calibration equipment used and the period of validity: Equipment Equipment name: Equipment name: name: GIGALAB Model 9265.043 Q00717 Kvalifik Kft. S.N.: 222016 K/23303 Drylogger S.N.: 201802 Kalibra 59 Humidity-meter: Drylogger S.N.: 201802 Equipment name: Resistance-meter: Equipment name: 2014.04.28. 2014.04.28. Kalibra 59 K/23303 2014.04.28. Tool name: Tool name: Tool name: Kvalifik Kft. Q00717 2014.04.28. Kvalifik Kft. Q00717 2014.04.28. Other used tools: Tool name: 5 pound electrodes (S.N.: 142298, 142299) Ring weight elektrodes (S.N.: HI-104879-0105, HI-104880-0105) Measuring cables, measuring clips Measured by: Name: Drágán Tamás (ESD technikus) Telefon: 06 30/217-6884 Fax: 06 34/300-142 E-mail: [email protected] Requestor and auditor of the measuring: Name: Godó Attila (ESD szakértő) Telefon: 06 34/300-142 (30/216-4583) Fax: 06 34/300-142 E-mail: [email protected] Page: 4/1 This report is not valid whitout the data, measuring results and the signature of the responsible persons! Protocol No.: 20140303-1ESD_Dr. Schutz_eng 2800 Tatabánya - Hungary Cseresznyefa u. 60/3 Tel/Fax: 06/34 300-142 Mobil 1: 06/30 216-4583 E-mail: [email protected] ESD audit and measuring report Qualifier sheet MUF_07_05_01D-5 Revízió: 05 Kiadás dátuma: 2013.10.01. Measuring result Conform S Code: Description of the product: Non conformance U1 – critical U2 – major U3 – minor Measuring results of the electrostatic protection: Not applicable N/A Rg (GROUNDING) Measured value Resistance - Ω Rpp (Point to point) Measured value Resistance - Ω Remarks: Code: N°: 1 2 3 4 5 6 7 8 Deposited on a conductive surface ESD PVC PU sealer Transparent type Deposited on a conductive surface ESD PVC PU sealer Between the original surface and the treated surface PU Transparent type Deposited on a conductive surface ESD Epoxy PU sealer Transparent type Deposited on a conductive surface ESD Epoxy PU sealer Between the original surface and the treated surface PU Transparent type Deposited on a conductive surface ESD Epoxy PU sealer Colored type Deposited on a conductive surface ESD Epoxy PU sealer Between the original surface and the treated surface PU Colored type PVC floor PU sealer coating Transparent type PVC floor PU sealer coating Colored type Expected: Measured: 3. Minta S Rg<109 723x103 3. Minta S - - 8. Minta S Rg<109 140x103 8. Minta S - - 7. Minta S Rg<109 13,3x106 7. Minta S - - 6. minta S Rg<109 25,4x106 5. minta S Rg<109 367x106 Rsys (SYSTEM) Measured value Resistance - Ω Expected: Rsys1<35x106 Rsys2<1x109 - Rsys1<35x106 Rsys2<1x109 - Rsys1<35x106 Rsys2<1x109 Rsys1<35x106 Rsys2<1x109 Rsys1<35x106 Rsys2<1x109 Measured: Expected: Measured: 30,8x106 Rpp<109 909 x103 - Rpp<109 6,16x106 8,46x106 Rpp<109 140 x103 - Rpp<109 105x103 5,31x106 Rpp<109 218x106 - Rpp<109 14,5x106 - Rpp<109 17,1x106 - Rpp<109 282x106 Inspection notes, deficiencies described: 1. The PU sealing complies with the IEC 61340-5-1, ANSI / ESD S20.20 ESD standards requirements. 2. The PU sealing complies with the IEC 61340-4-1,4-5, ANSI S7.1, STM97.1 standards requirements. 3. Page: 4/2 03.03.2014. Drágán Tamás Godó Attila Date: Signature of assessor Measuring auditing signature: This report is not valid whitout the data, measuring results and the signature of the responsible persons! Protocol No.: 20140303-1ESD_Dr. Schutz_eng 2800 Tatabánya - Hungary Cseresznyefa u. 60/3 Tel/Fax: 06/34 300-142 Mobil 1: 06/30 216-4583 E-mail: [email protected] ESD audit and measuring report Qualifier sheet MUF_07_05_01D-5 Revízió: 05 Kiadás dátuma: 2013.10.01. The measurement of the photos taken: Deposited on a conductive surface ESD PVC PU sealer Transparent type – Rpp – 3. Minta Deposited on a conductive surface ESD PVC PU sealer Transparent type – Rg– 3. Minta Deposited on a conductive surface ESD Epoxy PU sealer Transparent type – Rpp – 8. Minta Deposited on a conductive surface ESD Epoxy PU sealer Transparent type – Rg - 8. Minta Deposited on a conductive surface ESD Epoxy PU sealer Colored type – Rpp – 7. minta Deposited on a conductive surface ESD Epoxy PU sealer Colored type – Rg - 7. minta Page: 4/3 Deposited on a conductive surface ESD PVC PU sealer Transparent type - Rsys– 3. Minta Deposited on a conductive surface ESD PVC PU sealer Between the original surface and the treated surface PU Transparent type – Rpp– 3. Minta Deposited on a conductive surface ESD Epoxy PU sealer Between the original surface and the treated surface PU Transparent type – Rpp - 8. Minta Deposited on a conductive surface ESD Epoxy PU sealer Colored type - Rsys– 7. Minta Deposited on a conductive surface ESD Epoxy PU sealer Between the original surface and the treated surface PU Colored type – Rpp - 7. minta PVC floor PU sealer coating Transparent type– Rpp – 6. Minta PVC floor PU sealer coating Transparent type– Rg - 6. Minta PVC floor PU sealer coating Colored type– Rpp – 5. Minta PVC floor PU sealer coating Colored type– Rg - 5. Minta This report is not valid whitout the data, measuring results and the signature of the responsible persons! Protocol No.: 20140303-1ESD_Dr. Schutz_eng 2800 Tatabánya - Hungary Cseresznyefa u. 60/3 Tel/Fax: 06/34 300-142 Mobil 1: 06/30 216-4583 E-mail: [email protected] Page: 4/4 ESD audit and measuring report Qualifier sheet This report is not valid whitout the data, measuring results and the signature of the responsible persons! MUF_07_05_01D-5 Revízió: 05 Kiadás dátuma: 2013.10.01. Protocol No.: 20140303-1ESD_Dr. Schutz_eng
© Copyright 2024