50 Hz Gas Furnace Product Bulletin XE 80 TUD-C 072,090,108,126 BTUH IPB-FURN-EN-10-15-99 General Features Natural Gas Models Central heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. Safe Operation The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. Quick Heating Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive dishcarge of gas fumes to the outside, allows common venting with hot water heater. Burners Multi-port in-shot burners will give years of quiet and efficient service. All models can be converted to LP gas without changing burners. Integrated System Control Exclusively designed operation program provides total control of funace limit sensors, blowers, gas valve, flame control and includes self-diagnostics for ease of service. ©American Standard Inc. 1999 Air Delivers The multispeed, direct drive blower motor, with sufficient airflow range for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. Styling Heavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. Features and General Operation The XE 80 High Efficiency Gas Furnaces employ a Direct Spark Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter. b. Vent providing differential switch. IPB-FURN-EN-10-15-99 Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data TUD072CA36A TUD090CA48A TUD108CA54A TUD126CA60A IPB-FURN-EN-10-15-99 4 4 5 5 5 5 5 Product Data 6 Electrical Data 7 Field Wiring 9 Dimensions 10 3 Features and Benefits TUD-C Standard Equipment • Convertible to horizontal with left or right airflow • Slide out blower assembly • Power supply 220/1/50 • Adjustable fan off times • Direct spark ignition • Common vent capability • Integrated system control • Cleanable high velocity filters • Attractive color accents • Heavy gauge reinforced wrap-around steel cabinet • Heavy gauge aluminized steel heat exchanger • Direct drive, 4-speed motors • Super quiet performance • Blower door safety switch • Optional L.P. conversion kit • Complete front service access • Left/right gas connection • Alternate bottom/left/right return air • One-year part warranty Optional Equipment for Heating Units Thermostat ........................................................................................ BAYSTAT388 [ Thermostat-Htg/Clg ............................................................................... AY28X092 [ Thermostat-Htg ................................................................................. BAYSTAT303 [ Thermostat ........................................................................................ BAYSTAT305 [ XT 300 Programmable Thermostat .................................................... TAYSTAT300 [ Propane Conversion Kit ................................................................. BAYLPKT210A [ Coil Enclosure (Knock-down) ........................................................ BAYCLE1400C [ Coil Enclosure (Knock-down) ........................................................ BAYCLE1700C [ Coil Enclosure (Knock-down) ........................................................ BAYCLE2100C [ Coil Enclosure (Knock-down) ........................................................ BAYCLE2400C [ High Altitude Pressure Switch Kit ..................................................... BAYHALT238 [ Side Filter Rack ................................................................................. BAYFLTR200 [ Twinning Kit .................................................................................... BAYTWIN400A [ 4 ] ] ] ] ] ] ] ] ] ] ] ] ] IPB-FURN-EN-10-15-99 General Data TUD-C Product Specifications 1 Model TUD072CA36A Ratings 2 Input BTUH 72,000 Capacity BTUH (ICS) 3 56,700 AFUE (ICS) 80.0 Temp. Rise (Min.-Max.) °F 30-60 Blower Drive Direct Dia.-Width (in.) 10 x 7 No. Used 1 Speeds (No.) 4 CFM vs. in. w.g. See Fan Perf. Table Motor HP 1/3 R.P.M. 934 Volts/Ph/Hz 220/1/50 Combustion Fan — Type Centrifugal Drive — No. Speeds Direct - 1 Motor HP — RPM 1/50 - 2850 Volts/Ph/Hz 220/1/50 FL Amps .70 Filter — Furnished? Yes Type Recommended High Velocity Filter (No.-Size-Thk.) 1 - 17 x 25 x 1 in. Vent — Size (In.) 4 Round Heat Exchanger Type-Fired Aluminized Steel Type 1 -Unfired Gauge (Fired) 20 Orifices — Main Nat. Gas Qty. — Drill Size 4-47 L.P. Gas Qty. — Drill Size 4-56 Gas Valve Redundant — Single Stage Direct Ignition Device Type Direct Spark Ignitor Burners — Type In-Shot Number 4 Power Conn. — V/Ph/Hz 4 220/1/50 Ampacity (In Amps) 6.0 Max. Overcurrent Protection (Amps) 15 Pipe Conn. Size (In.) 0.50 Duct Conn. See Outline Drawing Dimensions HxWxD Crated (In.) 41-3/4 x 19-1/2 x 30-1/2 Uncrated See Outline Drawing Weight Shipping (Lbs.)/Net (Lbs.) 142/132 TUD090CA48A TUD108CA54A TUD126CA60A 90,000 71,100 80.0 35-65 Direct 10 x 8 1 4 See Fan Perf. Table 1/2 1040 220/1/50 Centrifugal Direct - 1 1/50 - 2850 220/1/50 .70 Yes High Velocity 1 - 20 x 25 x 1 in. 4 Round 108,000 85,500 80.0 35-65 Direct 11 x 10 1 4 See Fan Perf. Table 3/4 1060 220/1/50 Centrifugal Direct - 1 1/50 - 2850 220/1/50 .70 Yes High Velocity 1 - 20 x 25 x 1 in. 4 Round 126,000 99,900 80.0 40-70 Direct 11 x 10 1 4 See Fan Perf. Table 3/4 1,060 220/1/50 Centrifugal Direct - 1 1/50 - 2850 220/1/50 .70 Yes High Velocity 1 - 24 x 25 x 1 in. 4 Round Aluminized Steel Type 1 Aluminized Steel Type 1 Aluminized Steel Type 1 20 20 20 5-47 5-56 Redundant — Single Stage 6-47 6-56 Redundant — Single Stage 7-47 7-56 Redundant — Single Stage Direct Spark Ignitor In-Shot 5 220/1/50 7.5 15 0.50 See Outline Drawing HxWxD 41-3/4 x 23 x 30-1/2 See Outline Drawing Direct Spark Ignitor In-Shot 6 220/1/50 10.0 15 0.50 See Outline Drawing HxWxD 41-3/4 x 23-1/2 x 30-1/2 See Outline Drawing Direct Spark Ignitor In-Shot 7 220/1/50 10.0 15 0.50 See Outline Drawing HxWxD 41-3/4 x 26-1/2 x 30-1/2 See Outline Drawing 162/151 176/164 193/181 NOTES: 1 Central Furnace heating designs are certified by the International Approval Services. 2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 3 Based on U.S. Government Standard Tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. IPB-FURN-EN-10-15-99 5 Product Data TUD-C Furnace System Capacities with Flush Cased Coil and Cooling only Outdoor Units Furnace Model TUD072CA36A Furnace Width 17.5" TUD090CA48A 21" Twinned Furnaces TUD108CA54A 21" TUD126CA60A 24.5" CFM 800 1000 1200 1200 1400 1600 3200 1200 1400 1600 2000 1600 2000 Flush Fit Cased Coils TXC025C4HPB TXC031C4HPB TXC036C4HPB TXC037C4HPB TXC043C4HPB TXC049C4HPB (2) TXC043C4HPB TXC037C4HPB TXC043C4HPB TXC049C4HPB TXC060C5HPA TXC050C4HPB TXC061C5HPB System Cooling Cap Mbh 24Mbh 30Mbh 36Mbh 36Mbh 42Mbh 48MBh 90MBh 36Mbh 42 Mbh 48Mbh 60Mbh 48Mbh 60Mbh O.D.Unit TTB520/524 TTA030/TTB530 TTA036/TTB536 TTA036/TTB536 TTA042 TTA048 TTA100 TTA036/TTB536 TTA042 TTA048 TTA060/TTK060 TTA048 TTA060/TTK060 NOTES: TXC Coils required for Flush fit on some combinations. System Cooling capacities based on @400CFM/T matching Cased coil with Outdoor unit TUD-C Furnace Airflow (CFM) Vs. External Static Pressure (ins. w.g.) Model TUD072CA36A TUD090CA48A TUD108CA54A TUD126CA60A Speed Tap High Med Hi Med Lo Low High Med Hi Med Lo Low High Med Hi Med Lo Low High Med Hi Med Lo Low 0.0 1459 1306 1164 1020 1788 1604 1443 1279 2126 1910 1655 1418 2155 1897 1614 1389 0.3 1358 1203 1071 925 1673 1498 1346 1185 1980 1763 1503 1256 2048 1790 1507 1279 0.5 1291 1140 1001 855 1586 1397 1288 1122 1869 1663 1404 1149 1975 1718 1428 1189 0.7 1207 1060 925 776 1491 1359 1210 1056 1750 1555 1287 1028 1871 1620 1341 1078 0.9 1124 976 836 678 1387 1267 1100 953 1630 1432 1160 927 1746 1489 1230 977 CFM Vs. Temperature Rise Model TUD072CA36A TUD090CA48A TUD108CA54A TUD126CA60A CFM (Cubic Feet per Minute) 500 600 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 56 49 44 40 37 34 32 67 62 57 53 49 46 44 41 39 63 59 56 52 49 47 69 65 61 58 55 2000 2100 2200 2300 2400 37 44 52 42 49 40 47 45 From Dwg. 21C340782 Rev. 1 6 IPB-FURN-EN-10-15-99 Electrical Data Wiring Diagram For Gas Furnaces TUD072, 090, 108, 126C continued on next page IPB-FURN-EN-10-15-99 7 From Dwg. 21D341019 P01 Electrical Data Schematic Diagram For Gas Furnaces TUD072, 090, 108, 126C LEGEND SYMBOLS From Dwg. 21D341019 P01 8 IPB-FURN-EN-10-15-99 Field Wiring Diagram For Heating Only From Dwg. B341028 Diagram For Heating/Cooling (Outdoor Section Without Transformer) From Dwg. B341029 IPB-FURN-EN-10-15-99 9 Dimensions TUD-C Outline Drawing NOTE: ALL DIMENSIONS ARE IN INCHES Model TUD072CA36A TUD090CA48A TUD108CA54A TUD126CA60A 10 A 17-1/2" B 9-5/8" C 16-1/4" D 16 21" 13-1/16" 19-3/4" 19-1/2" 24-1/2" 15-5/16" 23-1/4" 23" IPB-FURN-EN-10-15-99 Notes IPB-FURN-EN-10-15-99 11 The Trane Company Trane International Unitary Systems 1789 Chaussée de Wavre 1160 Brussels Belgium www.trane.com An American Standard Company File Number IPB-FURN-EN-10-15-99 Supersedes IPB-FURN-94 Stocking Location P.I.-L Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. P.I.
© Copyright 2024