GYN 30-6 06/2014-E Simple, Fast and Efficient: The BRUCKER/MESSROGHLI SupraLoop – Unipolar Loop for Laparoscopic Supracervical Hysterectomy (LASH) The BRUCKER/MESSROGHLI SupraLoop Supracervical hysterectomy is becoming ever more widely employed because of the diverse range of advantages it offers for the patient: • preservation of anatomical structures (vagina, vaginal portion of the cervix, uterosacral ligaments) • organ-preserving intervention (only diseased tissue is removed) • lower postoperative incidence of pelvic organ prolapse • retention of sexual feeling following the operation The new BRUCKER/MESSROGHLI SupraLoop has been developed to facilitate the effective performance of this operation by allowing the quicker, safer supracervical removal of the uterus. Unipolar loop, single use Handle with connector for unipolar coagulation, reusable, autoclavable Outer sheath, insulated, reusable, autoclavable The advantages for the surgeon are obvious: • the simplest, safest operation in laparoscopic supracervical hysterectomy • reduction of operating times thanks to quick separation of the uterus from the cervix • additional cost savings thanks to the reusable handle and outer sheath; both parts are autoclavable • only the loop itself must be changed after each intervention PD Dr. Sara Brucker University Gynecology Clinic Tübingen 2 3 Application in laparoscopic supracervical hysterectomy (LASH) The SupraLoop is inserted into the abdominal cavity via a 6 mm trocar. The loop is then positioned around the uterus, … … after carefully checking the correct positioning, the loop is retracted … … and the uterus is removed with unipolar current … … and morcellated with the reliable ROTOCUT G1. The BRUCKER/MESSROGHLI SupraLoop for use in laparoscopic supracervical hysterectomy (LASH), with connection for unipolar coagulation 26183 MC 26183 MB 26183 M 26183 MA BRUCKER/MESSROGHLI SupraLoop, size 5 mm, length 30 cm, including: Handle, with connector pin for unipolar coagulation Outer Sheath, insulated, size 5 mm, length 30 cm Spare Loop, size 120 × 85 mm, for single use only, for use with handle 26183 MA and outer sheath 26183 MB Necessary accessories: 26183 MD Spare Loop, large, size 200 × 150 mm, for single use only, for use with handle 26183 MA and outer sheath 26183 MB 26002 M Unipolar High Frequency Cord, with 4 mm plug for HF unit, models KARL STORZ and Erbe type T, older models, length 300 cm 26004 M Unipolar High Frequency Cord, with 4 mm plug for HF unit, models Berchtold and Martin, length 300 cm 26005 M Unipolar High Frequency Cord, with 5 mm plug for HF unit, models KARL STORZ AUTOCON® system (50, 200, 350), AUTOCON®II 400 (111, 115) and Erbe type ICC, length 300 cm 26006 M Unipolar High Frequency Cord, with 8 mm plug for HF unit, models KARL STORZ AUTOCON®II 400 (112, 116) and Valleylab, length 300 cm 4 5 AUTOCON® II 400 HF Surgery Unit for interdisciplinary High Frequency Surgery • Interdisciplinary use • HF unit with a 6.5" touch screen for simple, safe, ergonomic operation and cleaning • Preprogrammed settings available for certain procedures; settings for other procedures can be additionally programmed easily and quickly We recommend the use of the BRUCKER/MESSROGHLI SupraLoop Unipolar Loop together with the AUTOCON® II 400 from KARL STORZ. The footswitch is used to apply unipolar current, which is transferred to the loop via a high frequency cable. Once the uterus has been separated via laparoscopic supracervical hysterectomy (LASH), other possible hemorrhaging and the cervical canal can be coagulated with bipolar current. 20 5352 01-125Autocon® II 400 High End, Set, SCB, power supply 220 - 240 VAC, 50/60 Hz, HF connecting sockets: bipolar combination multifunction, unipolar 3-pin + Erbe neutral electrode combination 6.3 mm jack and 2-pin, System requirements: SCB R-UI Software Release 20090001-43 or higher including: Mains Cord SCB Connecting Cable, length 100 cm Necessary Accessories: 20 0178 31 Three-pedal footswitch for use with HF generators Autocon® II 400 and Autocon® II 200 26176 LE Bipolar High Frequency Cord for KARL STORZ AUTOCON® system (50, 200, 350), AUTOCON® II 400 (Tpe 111, 113, 115) and Erbe-Coagulator, T- and ICC-row, length 300 cm 26005 M Unipolar High Frequency Cord with 5 mm plug for HF unit, models KARL STORZ AUTOCON® system (50, 200, 350) AUTOCON® II 400 (Tpe 111, 115) and Erbe type ICC; length 300 cm 27805 Neutral Electrode made of conductive silicone, with 2 rubber straps for fastening, for use with KARL STORZ AUTOCON® (type 200, 350), AUTOCON® II 400 (type 111, 115) A= 500 cm² surface area 27806 Connecting Cord, for connecting the neutral electrodes 27805 and 860021 E, length 400 cm Notes 6 7 Notes It is recommended to check the suitability of the product for the intended procedure prior to use. Consent to receive electronic information 96122023 GYN 30-6 06/2014/EW-E q Yes, I agree to receive future information by email at the following address: Email Name Department / Practice Street address ZIP, Town Signature I agree to my data being stored at KARL STORZ for this purpose. I can withdraw my consent at any time and without giving reasons by emailing KARL STORZ at [email protected]. KARL STORZ will not make these data available to third parties. KARL STORZ Endoscopy-America, Inc. 2151 East Grand Avenue El Segundo, CA 90245-5017, USA Phone: +1 424 218-8100 Phone toll free: 800 421-0837 (US only) Fax: +1 424 218-8525 Fax toll free: 800 321-1304 (US only) E-Mail: [email protected] 96122023 GYN 30-6 06/2014/EW-E KARL STORZ GmbH & Co. KG Mittelstraße 8, 78532 Tuttlingen, Germany Postbox 230, 78503 Tuttlingen, Germany Phone: +49 (0)7461 708-0 Fax: +49 (0)7461 708-105 E-Mail: [email protected] www.karlstorz.com
© Copyright 2024