Simple, Fast and Effi cient: The BRUCKER/MESSROGHLI SupraLoop – Unipolar Loop

GYN 30-6 06/2014-E
Simple, Fast and Efficient:
The BRUCKER/MESSROGHLI SupraLoop – Unipolar Loop
for Laparoscopic Supracervical Hysterectomy (LASH)
The BRUCKER/MESSROGHLI SupraLoop
Supracervical hysterectomy is becoming ever more widely employed because of the diverse
range of advantages it offers for the patient:
•
preservation of anatomical structures (vagina, vaginal portion of the cervix,
uterosacral ligaments)
•
organ-preserving intervention (only diseased tissue is removed)
•
lower postoperative incidence of pelvic organ prolapse
•
retention of sexual feeling following the operation
The new BRUCKER/MESSROGHLI SupraLoop has been developed to
facilitate the effective performance of this operation by allowing the quicker,
safer supracervical removal of the uterus.
Unipolar loop, single use
Handle with connector for
unipolar coagulation,
reusable, autoclavable
Outer sheath, insulated,
reusable, autoclavable
The advantages for the surgeon are obvious:
•
the simplest, safest operation in laparoscopic supracervical hysterectomy
•
reduction of operating times thanks to quick separation of the uterus from the cervix
•
additional cost savings thanks to the reusable handle and outer sheath; both parts are
autoclavable
•
only the loop itself must be changed after each intervention
PD Dr. Sara Brucker
University Gynecology Clinic Tübingen
2 3
Application
in laparoscopic supracervical hysterectomy (LASH)
The SupraLoop is inserted into
the abdominal cavity via a 6 mm
trocar.
The loop is then positioned around
the uterus, …
… after carefully checking the
correct positioning, the loop is retracted …
… and the uterus is removed
with unipolar current …
… and morcellated with the reliable
ROTOCUT G1.
The BRUCKER/MESSROGHLI SupraLoop
for use in laparoscopic supracervical hysterectomy (LASH),
with connection for unipolar coagulation
26183 MC
26183 MB
26183 M
26183 MA
BRUCKER/MESSROGHLI SupraLoop,
size 5 mm, length 30 cm,
including:
Handle, with connector pin for unipolar coagulation
Outer Sheath, insulated, size 5 mm, length 30 cm
Spare Loop, size 120 × 85 mm,
for single use only, for use with handle 26183 MA and
outer sheath 26183 MB
Necessary accessories:
26183 MD
Spare Loop, large, size 200 × 150 mm, for single use only,
for use with handle 26183 MA and outer sheath 26183 MB
26002 M
Unipolar High Frequency Cord,
with 4 mm plug for HF unit, models KARL STORZ
and ­Erbe type T, ­older models, length 300 cm
26004 M
Unipolar High Frequency Cord,
with 4 mm plug for HF unit, models Berchtold and Martin,
length 300 cm
26005 M
Unipolar High Frequency Cord,
with 5 mm plug for HF unit, models
KARL STORZ AUTOCON® system (50, 200, 350),
AUTOCON®II 400 (111, 115) and Erbe type ICC, length 300 cm
26006 M
Unipolar High Frequency Cord, with 8 mm plug
for HF unit, models KARL STORZ AUTOCON®II 400 (112, 116)
and Valleylab, length 300 cm
4 5
AUTOCON® II 400 HF Surgery Unit
for interdisciplinary High Frequency Surgery
• Interdisciplinary use
• HF unit with a 6.5" touch screen for simple, safe, ergonomic operation
and cleaning
• Preprogrammed settings available for certain procedures; settings for other
procedures can be additionally programmed easily and quickly
We recommend the use of the BRUCKER/MESSROGHLI SupraLoop Unipolar Loop together
with the AUTOCON® II 400 from KARL STORZ. The footswitch is used to apply unipolar
current, which is transferred to the loop via a high frequency cable. Once the uterus has been
separated via laparoscopic supracervical hysterectomy (LASH), other possible hemorrhaging
and the cervical canal can be coagulated with bipolar current.
20 5352 01-125Autocon® II 400 High End, Set, SCB,
power supply 220 - 240 VAC, 50/60 Hz, HF connecting sockets:
bipolar combination multifunction, unipolar 3-pin + Erbe neutral electrode
combination 6.3 mm jack and 2-pin, System requirements:
SCB R-UI Software Release 20090001-43 or higher
including:
Mains Cord
SCB Connecting Cable, length 100 cm
Necessary Accessories:
20 0178 31
Three-pedal footswitch for use with HF generators Autocon® II 400 and Autocon® II 200
26176 LE
Bipolar High Frequency Cord for KARL STORZ AUTOCON® system (50, 200, 350),
AUTOCON® II 400 (Tpe 111, 113, 115) and Erbe-Coagulator, T- and ICC-row,
length 300 cm
26005 M
Unipolar High Frequency Cord with 5 mm plug for HF unit,
models KARL STORZ AUTOCON® system (50, 200, 350) AUTOCON® II 400
(Tpe 111, 115) and Erbe type ICC; length 300 cm
27805
Neutral Electrode made of conductive silicone, with 2 rubber straps for fastening,
for use with KARL STORZ AUTOCON® (type 200, 350), AUTOCON® II 400 (type 111, 115)
A= 500 cm² surface area
27806
Connecting Cord, for connecting the neutral electrodes 27805 and 860021 E,
length 400 cm
Notes
6 7
Notes
It is recommended to check the suitability of the product for the intended procedure prior to use.
Consent to receive electronic information
96122023 GYN 30-6 06/2014/EW-E
q
Yes, I agree to receive future information by email at the following address:
Email
Name
Department / Practice
Street address
ZIP, Town
Signature
I agree to my data being stored at KARL STORZ for this purpose. I can withdraw my consent at any time and without giving reasons by emailing KARL STORZ
at [email protected]. KARL STORZ will not make these data available to third parties.
KARL STORZ Endoscopy-America, Inc.
2151 East Grand Avenue
El Segundo, CA 90245-5017, USA
Phone:
+1 424 218-8100
Phone toll free: 800 421-0837 (US only)
Fax:
+1 424 218-8525
Fax toll free:
800 321-1304 (US only)
E-Mail:
[email protected]
96122023 GYN 30-6 06/2014/EW-E
KARL STORZ GmbH & Co. KG
Mittelstraße 8, 78532 Tuttlingen, Germany
Postbox 230, 78503 Tuttlingen, Germany
Phone: +49 (0)7461 708-0
Fax:
+49 (0)7461 708-105
E-Mail: [email protected]