Lotryl® / Evatane® / Orevac® Grades Vinyl Acetate content (%) Melt index (190°C - 2.16kg) (g/10min) MAH content (ppm) Density (g/cm3) Melting point (°C) Vicat softening point (°C) Tensile strength at break (MPa) Elongation at break (%) 9307 Y 13 - 15 9.5 - 11.5 1600 0.939 93 66 19 600 - 900 9318 17 - 20 06 - 08 1600 0.943 86 54 20 600 - 900 9304 23.5 - 26.5 5.5 - 9.3 1600 0.950 80 49 26 600 - 900 9305 26 - 30 150 - 210 6400 0.951 68 <40 4.5 Test method Internal method ASTM D1238 ISO 1133 ISO 11357-3 ASTM D1525 ISO 306 EUROPE Headquater Arkema France 420, rue d’Estienne d’Orves 92700 COLOMBES FRANCE Tel.: (+33) 1 49 00 80 80 Fax: (+33) 1 49 00 83 96 NORTH AMERICA Arkema Inc. 900 First Avenue - P.O. Box 61536 19406-0936 KING OF PRUSSIA, PA UNITED STATES Tel.: (+1) 610 878 6500 Fax: (+1) 610 878 6400 ASTM D1505 ISO 1183 ASIA Arkema PTE Ltd - Branch Office 19th Floor, ITF Tower 140/40 Silom Road, Suriyawonge Bangrak 10500 BANGKOK THAILAND Tel.: (+66) 2 237 62 57 Fax: (+66) 2 237 5797 700 - 900 ASTM D638 ISO 527 SOUTH AMERICA Arkema Quimica Ltd Av. Ibarapuera 2033 4th flor - Moema 04029 - 901 SÃO PAULO BRAZIL Tel.: (+55) 11 21 48 85 22 ARKEMA - 420 rue d’Estienne d’Orves 92705 Colombes Cedex - France - A French société anonyme with a a share capital of 270 035 923 euros Registered in the Nanterre (France) Trade and Companies Register under the number 445 074 685 4368E/08.2014/20 - POF - Photos Arkema, Thinkstock, Fotolia - Conception/Réalisation : Rythmic 01 47 49 56 60 Terpolymer ethylene - Vinyl acetate Maleic anhydride A global chemical company and France’s leading chemicals producer, Arkema is building the future of the chemical industry every day. Deploying a responsible, innovation-based approach, we produce state-of-the-art specialty chemicals that provide customers with practical solutions to such challenges as climate change, access to drinking water, the future of energy, fossil fuel preservation and the need for lighter materials. With operations in more than 40 countries, some 14,000 employees and 10 research centers, Arkema generates annual revenue of €6.1 billion, and holds leadership positions in all its markets with a portfolio of internationally recognized brands. The statements, technical information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the product and of the information referred to herein are beyond our control, the data showed in the tables of this leaflet are typical values and cannot be considered as specifications. Arkema expressly disclaims any and all liability as to any results obtained or arising from any use of the product or reliance on such information; NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, IS MADE CONCERNING THE GOODS DESCRIBED OR THE INFORMATION PROVIDED HEREIN. The information provided herein relates only to the specific product designated and may not be,applicable when such product is used in combination with other materials or in any process. The user should thoroughly test any application before commercialization. Nothing contained,herein constitutes a license to practice under any patent and it should not be construed as an inducement to infringe any patent and the user is advised to take appropriate steps to be sure that,any proposed use of the product will not result in patent infringement. See MSDS for Health & Safety Considerations. The information contained in this document is based on trials carried out by our Research Centres and data selected from the literature, but shall in no event be held to constitute or imply any warranty, undertaking, express or implied commitment from our part. Our formal specifications define the limit of our commitment. No liability whatsoever can be accepted by Arkema with regard to the handling, processing or use of the product or products concerned which must in all cases be employed in accordance with all relevant laws and/or regulations in force in the country or countries concerned. Arkema has implemented an internal policy regarding the use of its products in medical devices applications that are in contact with the body or circulating bodily fluids. In addition, except for limited cases as determined by the Medical Device Policy, Arkema strictly prohibits the use of any Arkema products in Medical Device applications that are implanted in the body or in contact with bodily fluids or tissues for greater than 30 days.Arkema Functional Polyolefins are not designed neither produced in conditions suitable for medical device applications. Please contact Arkema sales representatives if you would like to use Arkema Functional Polyolefins in medical device applications. lotryl.com evatane.com Headquater: Arkema France 420, Rue d’Estienne d’Orves - 92700 Colombes - France Tel.: 33 (0)1 49 00 80 80 - Fax: 33 (0)1 49 00 83 96 arkema.com ethylene copolymers / Let’s progress together Ethylene - Acrylate copolymers Specified properties* Bases Grades 17BA04 EBA EMA Typical properties Main applications Hardness Comonomer content (%) Melt index (g/10 min) (190°C/2.16 kg) Melting point (°C) Vicat softening temperature (°C) Ring and ball temperature (°C) Tensile strength at break (MPa) Elongation at break (%) Flexural modulus (MPa) Shore A Shore D 16 - 19 3.5 - 4.5 93 60 - 15 700 45 - 32 Density (g/cm3) 15 - 19 6.2 - 8.3 93 58 - 15 700 40 - 30 0.93 28BA175 26 - 30 150 - 200 75 40 94 3 300 23 80 - 0.93 30BA02 28 - 32 1.5 - 2.5 75 41 >190 6 850 9 75 - 0.93 35BA40 33 - 37 35 - 45 66 <40 110 2 600 - 70 - 0.93 35BA320 33 - 37 260 - 350 65 <40 85 2 200 - 52 - 0.93 18MA02 17 - 20 2-3 83 53 - 13 700 50 - 25 0.94 20MA08 19 - 21 7-9 76 46 - 9 800 20 83 - 0.94 24MA005 23 - 26 0.4 - 0.6 72 45 - 17 750 18 84 - 0.94 24MA02 23 - 26 1-3 68 49 - 12 800 18 79 - 0.94 29MA03 27 - 31 2.0 - 3.5 61 <40 175 6 900 8 75 - 0.95 2407 23 - 25 6-8 69 <40 - 8 750 14 79 22 0.94 ASTM D1525 ISO 306 ASTM E28 NF EN1238 FTIR ASTM D1238 DSC Internal method ISO 1133 ISO 11357-3 * Properties routinely measured during the standard quality control procedure. Test method ASTM D638 ISO 527 ASTM D790 ISO 178 Films / Sheets Foams Coating Modification of thermoplastic polymers Cables 0.93 17BA07N Bestpeel Hot melt adhesives ASTM D2240 ISO 868 ASTM D1505 ISO 1183 EBA (Ethylene-Butyl Acrylate copolymer) EMA (Ethylene-Methyl Acrylate copolymer) Combined with Lotryl®, some masterbatches are available to enhance slip and antiblock properties. Ethylene - Vinyl acetate copolymers Specified properties* Bases EVA Typical properties Main applications Grades Comonomer content (%) Melt index (g/10 min) (190°C/2.16 kg) Melting point (°C) Vicat softening temperature (°C) Ring and ball temperature (°C) Tensile strength at break (MPa) Elongation at break (%) Hardness Shore A Density (g/cm3) 18 - 150 17 - 19 135 - 175 88 43 102 10 300 - 500 85 0.94 18 - 500 17 - 19 450 - 550 86 43 94 6 600 - 900 90 0.94 20 - 20 19 - 21 17 - 23 83 46 127 17 400 - 600 89 0.95 24 - 03 23 - 25 2.5 - 3.5 80 46 183 27 600 - 900 83 0.94 28 - 03 26 - 28 3 - 4.5 76 41 166 26 700 - 1000 82 0.95 28 - 05 27 - 29 5-8 72 40 160 24 700 - 1000 80 0.95 28 - 25 27 - 29 22 - 29 71 <40 120 14 800 - 1000 75 0.95 28 - 40 27 - 29 35 - 45 70 <40 106 10 800 - 1000 73 0.95 28 - 150 27 - 29 135 - 175 69 <40 95 8 400 - 600 71 0.95 28 - 420 27 - 29 370 - 470 66 <40 84 5 400 - 600 70 0.95 28 - 800 30 - 32 700 - 900 63 <40 80 3 400 - 600 60 0.95 33 - 25 32 - 34 22 - 29 63 <40 119 11 900 - 1100 67 0.96 33 - 45 32 - 34 38 - 48 62 <40 107 9 900 - 1100 63 0.96 33 - 45 PV 32 - 34 38 - 48 62 <40 107 9 900 - 1100 63 0.96 33 - 400 32 - 34 350 - 450 63 <40 84 4 400 - 600 60 0.96 40 - 55 38 - 41 48 - 62 55 <40 97 7 900 - 1100 50 0.96 42 - 60 >41 65 - 85 48 <40 95 5 900 - 1100 42 0.96 FTIR ASTM D1238 DSC ASTM D1525 ASTM E28 ASTM D638 ASTM D2240 ASTM D1505 Internal method ISO 1133 ISO 11357-3 ISO 306 NF EN 1238 ISO 527 ISO 868 ISO 1183 Test method * Properties routinely measured during the standard quality control procedure Hot Melt adhesives Films / Sheets Foams EVA (Ethylene-Vinyl Acetate copolymer) Sound dampening Bitumen Cables Crude Oil Ink Solar pannels Lotryl® / Evatane® / Orevac® Grades Vinyl Acetate content (%) Melt index (190°C - 2.16kg) (g/10min) MAH content (ppm) Density (g/cm3) Melting point (°C) Vicat softening point (°C) Tensile strength at break (MPa) Elongation at break (%) 9307 Y 13 - 15 9.5 - 11.5 1600 0.939 93 66 19 600 - 900 9318 17 - 20 06 - 08 1600 0.943 86 54 20 600 - 900 9304 23.5 - 26.5 5.5 - 9.3 1600 0.950 80 49 26 600 - 900 9305 26 - 30 150 - 210 6400 0.951 68 <40 4.5 Test method Internal method ASTM D1238 ISO 1133 ISO 11357-3 ASTM D1525 ISO 306 EUROPE Headquater Arkema France 420, rue d’Estienne d’Orves 92700 COLOMBES FRANCE Tel.: (+33) 1 49 00 80 80 Fax: (+33) 1 49 00 83 96 NORTH AMERICA Arkema Inc. 900 First Avenue - P.O. Box 61536 19406-0936 KING OF PRUSSIA, PA UNITED STATES Tel.: (+1) 610 878 6500 Fax: (+1) 610 878 6400 ASTM D1505 ISO 1183 ASIA Arkema PTE Ltd - Branch Office 19th Floor, ITF Tower 140/40 Silom Road, Suriyawonge Bangrak 10500 BANGKOK THAILAND Tel.: (+66) 2 237 62 57 Fax: (+66) 2 237 5797 700 - 900 ASTM D638 ISO 527 SOUTH AMERICA Arkema Quimica Ltd Av. Ibarapuera 2033 4th flor - Moema 04029 - 901 SÃO PAULO BRAZIL Tel.: (+55) 11 21 48 85 22 ARKEMA - 420 rue d’Estienne d’Orves 92705 Colombes Cedex - France - A French société anonyme with a a share capital of 270 035 923 euros Registered in the Nanterre (France) Trade and Companies Register under the number 445 074 685 4368E/08.2014/20 - POF - Photos Arkema, Thinkstock, Fotolia - Conception/Réalisation : Rythmic 01 47 49 56 60 Terpolymer ethylene - Vinyl acetate Maleic anhydride A global chemical company and France’s leading chemicals producer, Arkema is building the future of the chemical industry every day. Deploying a responsible, innovation-based approach, we produce state-of-the-art specialty chemicals that provide customers with practical solutions to such challenges as climate change, access to drinking water, the future of energy, fossil fuel preservation and the need for lighter materials. With operations in more than 40 countries, some 14,000 employees and 10 research centers, Arkema generates annual revenue of €6.1 billion, and holds leadership positions in all its markets with a portfolio of internationally recognized brands. The statements, technical information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the product and of the information referred to herein are beyond our control, the data showed in the tables of this leaflet are typical values and cannot be considered as specifications. Arkema expressly disclaims any and all liability as to any results obtained or arising from any use of the product or reliance on such information; NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, IS MADE CONCERNING THE GOODS DESCRIBED OR THE INFORMATION PROVIDED HEREIN. The information provided herein relates only to the specific product designated and may not be,applicable when such product is used in combination with other materials or in any process. The user should thoroughly test any application before commercialization. Nothing contained,herein constitutes a license to practice under any patent and it should not be construed as an inducement to infringe any patent and the user is advised to take appropriate steps to be sure that,any proposed use of the product will not result in patent infringement. See MSDS for Health & Safety Considerations. The information contained in this document is based on trials carried out by our Research Centres and data selected from the literature, but shall in no event be held to constitute or imply any warranty, undertaking, express or implied commitment from our part. Our formal specifications define the limit of our commitment. No liability whatsoever can be accepted by Arkema with regard to the handling, processing or use of the product or products concerned which must in all cases be employed in accordance with all relevant laws and/or regulations in force in the country or countries concerned. Arkema has implemented an internal policy regarding the use of its products in medical devices applications that are in contact with the body or circulating bodily fluids. In addition, except for limited cases as determined by the Medical Device Policy, Arkema strictly prohibits the use of any Arkema products in Medical Device applications that are implanted in the body or in contact with bodily fluids or tissues for greater than 30 days.Arkema Functional Polyolefins are not designed neither produced in conditions suitable for medical device applications. Please contact Arkema sales representatives if you would like to use Arkema Functional Polyolefins in medical device applications. lotryl.com evatane.com Headquater: Arkema France 420, Rue d’Estienne d’Orves - 92700 Colombes - France Tel.: 33 (0)1 49 00 80 80 - Fax: 33 (0)1 49 00 83 96 arkema.com ethylene copolymers / Let’s progress together
© Copyright 2024