HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
Technical
Specifications
Version 10-2014
INDEX
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Contact Information & General Information
Venue ruels
Stage access & Truck parking
Stage & Power
Light Equipment
Sound Equipment
Wardrobes, Catering, wi-fi & Hotels
Main Concert Hall - Stage rigging plot
Main Concert Hall - Floor plan, with seats
Main Concert Hall - Floor plan, Balconies
Main Concert Hall - Cross section
Main Concert Hall - Floor plan, no seats
Main Concert Hall - Photo
Kvium Concert Hall - Floor plan
Loadtable
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
CONTACT INFORMATION:
page
1
Adress:
Teatertorvet
DK- 8700 Horsens
Denmark
( GPS: 55.51.79N 09.50.85O )
Postal adress:
P.O.Box 187 - DK 8700 Horsens
Administration:
Box Office + 45 75 60 23 44
Administration + 45 75 60 24 44
Mail [email protected]
Official Website www.hnt.dk
Stagemanager:
Torben Simonsen
+ 45 75 26 24 32
Mail [email protected]
Drawings and specs.
www.hnt.dk/?info=9
Catering:
Casper Jørgensen
Mail
+ 45 75 26 24 22
[email protected]
GENERAL INFORMATION:
The venue contains two concert halls, the Main Concert Hall and the Kvium Concert
Hall. The main concert hall is where most concerts and theater productions are held. T he
Kvium Concert Hall is mainly used for classical concerts or receptions, and is therefore not
mentioned much in this technical specification.Each hall can be fitted with chairs.
Capacity:
Main Concert Hall:
With chairs: 540
No chairs: 755
Kvium Concert Hall:
With chairs: 150
No chairs: 200
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
page
VENUE RUELS
2
SOUNDLIMITS
According to EU noise regulations, we are enforcing a 103dB(A) limit (average over 15
minutes, measured at FOH).
This ensures a healthy environment for both the audience and the employees.
SMOKING
Due to national law, al kinds of smoking indoor are prohibited.
FIRE/PYROTECHNICS
All use of open fire and pyrotechnic products are prohibited at Horsens Ny Teater, unless it’s been aproveed in advance by the local fire authorities and the stagemanager at
Horsens Ny Teater.
Contact our local fire chief Lars Bøndig
(Tlf.: + 45 76 29 27 76 or on e-mail [email protected])
minimum 4 weeks before your production arrives at Horsens Ny Teater.
CONFETTI
Use of confetti products must be approved by Horsens Ny Teater before get-in.
Contact our stage manager Torben Simonsen ([email protected]) to do this.
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
page
STAGE ACCESS & TRUCK PARKING
3
STAGE ACCESS
Acces to ramp/lift (height 0,75 m) from Teatertorvet/Rædersgade, 8700 Horsens.
Mesurements on lift 4,0 x 2,50 m.
Capacity 2000 kg. Lift operates up to 1,75 m. Acces from lift directly to stage.
TRUCK PARKING
Horsens Ny Teater is located in the heart of Horsens city. Because of the location we don’t
have much parking space for trucks. T he maximum capacity at the load-in dock is two
semi-trailers at the time. VAN & CAR PARKING
Make sure to get a parking permit from the stage manager immediatly after arrival at
Horsens Ny Teater.
Horsens Ny Teater can not be held responsible and do not refund parking tickets.
Please notice!
The rute marked with yellow is a fire escape route, it’s not legal to park on it. T herefore the
truck must be detached from the trailer and parked elsewhere when not being used for
load-in or load-out. The stagemanager will help the truckdriver determin if this is necessary.
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
page
STAGE & POWER
STAGE
Stageheight:
1,10 meters (m)
Stage-mesurement - behind curtains:
Depth 10,75 m / width 12,70 m / Free-height 7,00 m
Stage-mesurements - in front of curtains:
Depth 2,00 m / width 12,70 m
Procenium:
Total-width 12,70 m /Effective width 11,50 m / heigth 6,44 m
Orchestra pit:
9,0 x 3,7 meters, - max.depth from stage: 1,80 m (Normally not opened)
Stageequipment - Lightbars (See loadtable):
12 x 11 m Manual bars on stage (rope/block)
6x
11 m Lightbars, manual with winch, on stage.
1x
11 m Lightbar, electrical winch over audience 2 mtr. from proscenium.
1x
11 m Lightbar, electrical winch over audience 5 mtr. from proscenium.
1x
11 m Lightbar, electrical winch over audience 8 mtr. from proscenium.
Stage equipment, misc.:
6x
Top borders: 11 x 1,8 m
12 x Side borders 7 x 1,9 m
1x
Moviescreen (8 x 5 m) (located on chainblocks on stage)
Risers:
13x
Sunstill 1 by 2 meter risers (optional heights: 20cm, 40cm and 60cm)
Crowdbarries:
At concerts with a standing audience we use crowdbarriers in front of the stage
and around the FOH.
POWER
Main Stage:
2 x 3 x 63 Amp. w. earth + zero CEE
2 x 3 x 32 Amp. w. earth + zero CEE
1 x 3 x 125 Amp. w. earth + zero CEE is an additional option.
Kvium Stage:
1 x 3 x 63 Amp. w. earth + zero CEE
4
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
LIGHT EQUIPMENT
page
5
Conventional lamps:
12 x
12 x
CCT Starlette fresnel
36 x
MAJOR P64 M. 220 V lamps
Movinghead lamps:
2x
STRATOS moving spots
3x
MARTIN Mac 2000 performance
12 x
COEMAR ProWash 250
Controllers:
1x
MA Lightcommander 24/48 ch.
2x
MA 2Port Node onPC (1024 adr.)
1x
MA onPC Command Wing (1024 adr.) With 23” touch screen PC
Dimmers:
4x
1x
Lightbars:
6x
3x
OT 12-pack theatre dimmers ( 16 Amp) (stationary)
Lightbars (stage) each with 12 plugs (16 Amp)
Lightbars (in front of stage) electrical winch and 12 plugs (16 Amp.)
Smokemachines:
1x
Swefog Ultimate 3000, Oilcracker
2x
Antari Z-1200II
There are no smokedetectors located at the venue, so you don’t have to ask before you
PLEASE NOTICE!
ALL LIGHTBARS ARE MADE OF SQUARE 30x50MM
PIPES.HALF COUPLERS AND SUPERCLAMPS WILL NOT
FIT.IF THIS IS A PROBLEM PLEASE LET US KNOW IN
ADVANCE!
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
SOUND EQUIPMENT
Desks:
1 x SOUNDCRAFT Vi6
1 x YAMAHA LS9
Fx´s:
1x
1x
1x
2x
TC Electronic M-ONE
DIGITECH DSP 256 XL
DRAWMER Dual Comp./lim. DL 221
DRAWMER Dual Gate DS 201
ain filter:
M
1x DBX 480Main PA/amps:
4 x d&b Ci7 top
(hanging, 2 pc. per side)
4 x d&b Ci7(sub) (below stage)
2 x d&b P1200 with ctrls. (2 x top + 2 x sub)
2 x d&b Ci9 (E9)(innerfill)
2 x d&b EPAC (for innerfill)
x
2
1x
Adamsson SX subs with lab.gruppen fp 6400 amp.
Monitor speaker/amps:
8 x JBL SM-115
3 x QSC MX 3000A
EQ´s
2 x KLARK DN 27 graphic EQ
page
6
Microphones:
1 x Shure SM 52 Beta
6 x Shure Sm 57 Beta
6 x Shure SM 57
5 x Shure SM 58 Beta A
1 x Shure SM 58 Beta
2 x Shure SM 58
1 x Shure SM 87 B
4 x Sennheiser 604
2 x sets of Behringer C-2 (4 mics)
2 x Audio-Technica AT 2020
2x
AKG 414
1 x RØDE NT-1
2X
RØDE NT-5
2 x Shure SM 91
2 x Shure SM 99
10 x LDI 20 DI
4 x SC 8401 DI
Stands:
6 x Straight
6 x Straight with boom.
6 x Straight (low)
2 x Straight (low) with boom.
Backline:
1 x ELECTRICAL PIANO (YAMAHA P-150)
1 x Grand Piano (2m.(B) STEINWAY)
Portable PA:
2 x d&b E 8
2 x d&b E15 sub
2 x d&b D6 amplifier
FOH position Horsens Ny Teater has two FOH positions, one position on the floor level, and one in the
studio on the 1st balcony.We normaly use the FOH position on the floor level, and we will
contact your production if we would like you to mix from the studio FOH position.
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
WARDROBES, CATERING & HOTELS
page
7
WARDROBES
20 seats/mirrors in 3 wardrobes.(above stage, on 2nd. floor)
seperat baths
3
Artist lounge, with tv, stereo, etc.
Washingmachine, tumble dryer and kitchen at your disposal.Unless anything else has
been arranged with the stage manager, we expect the wardrobes to be vacated 1 hour
after the show.
CATERING
atering will usually be served in the artist lounge. If you are traveling with a large
C
production (over 10 people), the catering will be served in “Sal 3”. (above stage, on the
1st floor.)Please contact Casper Jørgensen ([email protected]) if you have questions
concerning catering and wardrobes.
WI-FI
We have free wi-fi for all artists visiting Horsens Ny Teater.
Contact the stagemanager for log-in informations.
HOTELS
e cooperate with Jørgensens Hotel, Søndergade, DK-8700 Horsens
W
Phone + 45 75 62 16 00 Fax + 45 75 62 85 85
Please contact us, for fair prices.
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
MAIN CONCERT HALL - STAGE RIGGING PLOT
page
8
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
MAIN CONCERT HALL - FLOOR PLAN, WITH SEATS
page
9
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
page
10
MAIN CONCERT HALL - FLOOR PLAN, BALCONIES
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
MAIN CONCERT HALL - CROSS SECTION
Hydraulic floor:
From 5. row and backwards
the floor is raised 10 cm. for
each 2 rows.
With flat floor, the floor is
raised app. 0,5m., 13,5 m.
from stagefront!
All seats can be
moved/removed.
page
11
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
page
MAIN CONCERT HALL - FLOOR PLAN, NO SEATS 12
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
MAIN CONCERT HALL - PHOTO
FOH
Photo taken from the 1st balcony
The the main entrance
page
13
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
KVIUM STAGE
page
14
HORSENS NY TEATER - TECHNICAL SPECIFICATIONS
Loadtable
15
page