Damaca MRI 508 anaesthesia machine Dameca For excellence in anaesthesia Gauss and Tesla Gauss(G) and Tesla(T) are directly interrelated 1T equals 10,000G 0,0001T equals 1G Tesla represents the magnetic strength at the center of the MR scanner Gauss is typically used when expressing the strength of the magnetic field surrounding the MR scanner Dameca For excellence in anaesthesia High Gauss level equipment Major advantage of equipment tolerating a high Gauss level is that equipment can be placed close to diagnostic equipment such as scanner and new MR scanners become more and more powerful (=> 7T) Practical Operating the anaesthesia machine close to the scanner Safety No interference with diagnostic images No jamming of ventilator functions (halt) No attraction of anaesthesia machine to the scanner Dameca For excellence in anaesthesia Dameca MRI 508 — intuitive and easy-to-use Dameca Feature Benefits 3.0 Tesla approved Working together with state-of-the-art scanners Better diagnostics Tested up to 2,000 Gauss Work close to scanner Patient & Scanner safety Patient observation/monitoring Slim design Small footprint – occupies a minimum of space Same user interface throughout Siesta i series Dual use Time saving No specialised persons (education) Minimising risks of mis-use High performance anesthesia ventilator 8 ventilation modes incl. PRVT Broad patient range Same as the well-known Siesta i Whispa Integrated Breathing System (IBS) Patient safety, no leakage problems Easy cleaning procedure Low total costs of ownership (TCO) Low running costs Certificate from leading MR scanner manufacturers Can be used together with a very broad range of MRI scanners For excellence in anaesthesia Dameca MRI 508 ventilation modes Automatic Manual VCV — Volume Controlled Ventilation Manual PCV — Pressure Controlled Ventilation Spontanous SIMV — Synchronised Intermittent Mandatory Ventilation PSV — Pressure Support Ventilation PRVT — Pressure Regulated Volume Target VSV — Volume Support Ventilation Dameca For excellence in anaesthesia Dameca MRI 508 Vaporiser Machine Back bar for two Selectatec (German and Bristish standard) with interlock safety mechanism. 1510x760x670 Wheels/Breaks Twins - Interlock Drawers No Patient monitor mounting Brand independent Self test (time) 2-3min Ventilation meassurements Battery operation time 60min Tidal Volume AGS system 30-40L/min (Built-in) Adult 200-1500ml Paediatric 20-300ml Screen 8" TFT Colour Minut Volume PEEP Plateau Measured patient compliance Measured inspired 02 % Spirometry Loop Respiration rate I:E ratio Inspiratory pressure 0.2-60L/m Electronic 4-20hpa 0-70% VCV, PCV, PRVT, SIMV Yes Yes 4-80bpm 3:1 to 1:99 PCV PEEP + 7-67hpa PSV PEEP + 4-50hpa Patient System Description IBS (integrated breathing system) Mounting Left side Insp/Exp. valves flaps Vertical Disassembly for cleaning In 30sec. Disassembly without tools YES Freshgas introduced after insp. value YES Autoclavable YES Absurber capacity (disposable) 900gr. System compatible with standard anaesthesia machines Can be used on Siesta i Breasy, Siesta i Whispa and Siesta i TS Ventilator Type Microprocessor control Ventilation modes 8 VCV, PCV, SIMV, PSV, VSV, PRVT Manual spontaneous Dameca System Dimensions HxWxD i mm For excellence in anaesthesia Fresh Gas Flow Flow Rotameter 0-20 L/min Minoxyguard 3 tubes 5 tubes (option) MRI 508 vs. competition Dräger Fabius MRI Dameca MRI 508 Aestiva/5 MRI Dameca For excellence in anaesthesia MRI market comparison & positioning Features Dameca MRI 508 Dräger Fabius MRI GE Aestiva/5 MRI Gauss Tested up to 2,000 Rated up to 1,000 400 300 Tesla 3.0 3.0 3.0 Patient system compatibility Same as the Siesta i series Only Fabius series Only Aestiva User interface Same as the Siesta i series Only Fabius series Only Aestiva Integrated colour monitor/display 8” 6.5” External display Ventilation modes 8 adults / infants / neonates 6 adults / infants / neonates 5 adults / infants / neonates PRVT option yes No No Gauss alarm No No yes Yes Yes no Special audible & visual ventilator alarm Dameca incorporated in the alarm button For excellence in anaesthesia Philips - MRI compatibility statement Tested at the Philips MR scanner test facility in Best with a good result Tested with 1.0T to 3.0T scanners Dameca has tested the machine in addition with a number of different types of scanners Dameca For excellence in anaesthesia MRI safety space Dameca For excellence in anaesthesia
© Copyright 2024