Smart, Simple, PROVEN! The ORIGINAL “POND LOOP IN A PACKAGE” Unmatched In Performance & Quality The Original “POND LOOP IN A PACKAGE” Compact, Pre-Sized & Assembled • • • Proven Design Proven Pressure Drops Proven Performance What is a Slim Jim® / Geo Lake Plate® ? A simple, labor-friendly alternative to polyethylene pipe (lake loops) for fluid to fluid heat transfer in any watercooled equipment when a body of water can be utilized (ponds/lakes, rivers, oceans, waste water retention ponds, waste water treatment plants, etc.). • • • • Easy to install (labor friendly) Easy to flush No limit to job size - single to multiple units Available in 304 SS – Slim Jim®, 316L SS & Titanium – Geo Lake Plate®. • Third Party Tested by Ewbank & Associates Must stand vertical and be supported off the bottom – out of silt or mud and, the body of water must be adequate to handle the load! Size Does Matter! We Need Input! Slim Jim® / Geo Lake Plate® PROJECT INFORMATION SHEET Sheet Notes: (*) Required Information Text fields will expand to allow for complete information to be entered Use your “Tab” key or Mouse to move between fields Highlighted field with a “ ” on the right side of the field indicates selectable text When the sheet is complete save and include requested information before sending by email or fax to AWEB Supply *Date: Section 1 - General Information * Project name: Company name: Address: *Contact name: Phone No.: ext.: , *Location: , City: , State: Zip: - , *email: Fax No.: Section 2 – Design Heat Gain/Loss Calculation for Project *Total design peak heat gain (cooling): Btu/hr *Total design peak heat loss (heating): Btu/hr *Residential (Climate Driven Loads) No , Yes or Commercial (Internally Driven Loads) No *Copy attached , Yes Section 3 - Equipment Information – Heat Pump(s) or Chiller(s) *Manufacturer(s): , *Heat Pump or Chiller Model number(s): *Total tonnage of equipment: , Total number of units: Water-2-Water , Water-2-Air , Other *Equipment Performance Submittal Sheet(s) Attached *Project Heat Pump/Chiller Equipment Schedule Sheet(s) Attached Section 4 – Project Total Source Loop Requirements *Loop liquid type: Water , Methanol *Source Loop total flow rate: GPM %, Prop. Glycol %, Eth. Glycol % Section 5 – Total Cooling Requirement (Heat of Rejection (HR)) *Heat Pump(s)/Chiller(s) equipment design (HR) source flow rate GPM (Per Manufacture(s) Equipment Performance Sheet) *Total Heat of Rejection (HR) for project at 90ºF (EWT) Btu/hr (Per Manufacture(s) Equipment Performance Sheet) *Warmest Pond/Lake temperature at planned installation depth: ºF *Equipment(s) (HR) Performance Submittal Sheet(s) Attached Section 6 – Total Heating Requirement (Heat of Extraction/Adsorption (HE)) *Heat Pump(s)/Reversible Chiller(s) equipment design (HE) source flow rate GPM (Per Manufacture(s) Equipment Performance Sheet) *Total Heat of Extraction (HE) for project at 30ºF (EWT) Btu/hr (Per Manufacture(s) Equipment Performance Sheet) *Coldest Pond/Lake source temperature at planned installation depth: ºF *Equipment(s) HE Performance Submittal Sheet Attached Section 7 - Pond/Lake/River/Ocean Information Length: ft, Width: ft or Surface area: ft² *Planned Installation depth: ft, Average depth: ft, Deepest depth: *Will the surface water form ice in the winter: No , Yes Thickness ft Water type: Freshwater , Saltwater , Fresh/Saltwater , Other Is the installation body of water flow/moving: No , Yes ft AWEB Supply 7350 Tom Drive, Baton Rouge, LA 70806 225/928-2630 ● 888-277-2932 ● Fax 225-928-2087 Email: [email protected] ● website: www.awebgeo.com Rev:11/2012 Slim Jim® makes installation of GeoExchange in Ponds or Bodies of Water as Simple as it gets! 5 Tons(HR) SJ-05T Little Fusion Required …or No Fusion Single Plate Application 4 Tons(HR) SJ-04T Economical Stabilizer and Legs – PVC Pipe Single Plate Installation SJ-05T 5 Tons(HR) – SJ SS Legs (Optional) Multiple plates of like capacity can be manifold in field with PE pipe to accommodate Shallow Pond Applications 6 Tons(HR) 3 @ SJ-2T plates Multiple plates of like capacity can be manifold in field with PE pipe to accommodate Larger Loads 32 Ton (HR) 4 @ SJ-08T Plates 16 Ton (HR) 2 @ SJ-08T Plates 16 Ton(HR) No Manifold 2 @ SJ-08T Plates 24 Tons (HR) Total – 3 @ 8-Ton(HR) Circuits 6 @ SJ-04T Plates Or, AWEB can custom build assemblies with frame on skids, manifolds and flange connections 24 Ton(HR) 3 @ SJ-08T Plates 2” Manifolds 2” Flange Connections 4 Tons (HR) 2 @ SJ-02T Plates Pipe Thread Connections 6 Tons(HR) 3 @ SJ-2T Plates Low Profile – Shallow Pond 16 Ton(HR) 2 @ SJ-08T Plates 30 Tons(HR) 6 @ SJ-05TC (Low Profile) 40 Tons(HR) 4 @ SJ-10T Plates 40 Tons(HR) Total Two 20-Ton(HR) Circuits 4 @ SJ-10T Plates 50 Tons(HR) 5 @ SJ-10T Plates – Special Manifold 50 Ton(HR) 5 @ SJ-10T Plates – Special Manifold 60 Tons(HR) Total Geo Lake Plate® - Titanium 6 @ GLP-05TC (Titanium) Plates per Assembly 70 Tons (HR) 7 @ SJ-10T Plates 70 Tons(HR) 14 @ SJ-05TC Plates - Extended Legs 80 Ton(HR) 10 @ SJ-08T Plates 110 Ton(HR) 11 @ SJ-10T Plates 120 Tons(HR) Total 3 @ 40 Tons(HR) 120 Tons(HR) Total Each Assembly – 8 @ 10T Plates 200 Ton(HR) w/Deflector River Application – 20 @ SJ-10 Plates Versatility! Two SJ-02T plates anchored to a floating home Versatility for Space Limitations! Low Profile – 15 Ton(HR) Geo Lake Plate® - Titanium for Salt Water Applications Aquarium Project BC, Canada 15 Tons(HR) River Application 3 @ SJ-05TC Plates Special Manifold Deflector 15 Tons(HR) River Application Installation 32 Ton(HR) Total Two 16 Ton(HR) Circuits Marine Safety Station – Chicago, IL 96 Ton(HR) - Wisconsin Pine Haven Christian Home Wisconsin 160 Tons(HR) Two 80 Ton(HR) Slim Jim® Assemblies - OHIO 200 Ton(HR) Picture Perfect Cooling Tower Three Pillars Assisted Living Facility – Wisconsin – 200 Ton (HR) Single SJ-05T Slim Jim® Quebec, Canada SJ-05T Slim Jim® piped up - Legs being attached for installation Slim Jim® plate floated out to installation site Slim Jim® plate in position to be submerged Floating Home Application British Columbia, Canada Two SJ-02T (304SS) plates mounted directly to the concrete float and piped into the mechanical room. The top of the plates are 16" below the water surface. Home being floated to new home site Floating home being launched Home Site - New Westminster, British Columbia, Canada on the Fraser River 40 Ton(HR) Installation Baton Rouge, LA Dewey Short Visitor Center Table Rock Lake, Missouri 110 Tons(HR) 11 @ SJ-10T Plates – Oshkosh, WI 110 Ton (HR) Slim Jim® Heat Exchanger - Ready for Shipment Piped Up and Ready for Water – Front View Piped Up and Ready for Water – Side View Full View David Crockett State Park 120 Tons(HR) Total Two 60 Ton(HR) Slim Jim® exchangers are installed at David Crockett State Park Exchangers being moved to installation site Connecting the HDPE pipe to the Slim Jim® exchangers Slim Jim® exchanger being moved to installation site Lowering the SJ exchanger into the water. Stabilizers (PVC pipe capped on ends) allow the unit to float at the surface for positioning before flushing Flushing has begun - the exchangers descend to the bottom as they are filled with water. The stabilizer is not removed after flushing is complete. Installation Complete! Forks Market Project Winnipeg, Manitoba Canada – 400 Tons(HR) Total Project 1400 Tons(HR) 7 @ 200 Ton(HR) Slim Jim® Assemblies Installed Slim Jim® Assembly floated out to installation site Illustration of Installed Slim Jim® Assembly Kings Mill Hospital Project Kings Mill Hospital – Mansfield England Just Add Water! Eden Meadows (Lutheran Homes of Oshkosh), Oshkosh, Wisconsin – 110 Ton(HR) – Completed Project Thank You
© Copyright 2024