Façades and skylights Thermally insulated mullion-transom systems Steel systems For doors, windows and façades We take our inspiration from nature. The known structural benefits of plant stems and long bones are applied to steel profiles. The very slender profile dimensions mean more light and more scope for creativity. Architects, designers and users value the range of options available. Steel is robust and can withstand mechanical damage. Jansen profile systems are therefore particularly suitable for all buildings frequently used by the public: in commercial and industrial buildings, in schools and hospitals, sports and leisure centres, in service centres and railway stations. Of the materials widely used in building construction, steel has the highest modulus of elasticity, at around 210 kN/mm2. The material benefits offer new and interesting options in structural dimensioning, in fire applications, burglar-resistant constructions and in sound reduction. The wide range of products also includes thermally insulated systems and stainless steel profiles. Doors, windows and façades are created using Jansen tubular steel profile systems. Industrial pre-fabrication means simple, time-saving and cost-effective manufacture. Our comprehensive range of profiles is complemented by a complete range of fittings and accessories, and by ophisticated fabrication tools. In addition to technical documentation and specialist «Janisoft» planning software, comprehensive consultancy and training is available for architects, designers and fabricators. 3 Jansen-VISS Building on the benefits of steel VISS (a fully insulated glazing system) is a thermally insulated steel system for mullion/transom constructions. All manner of façades can be built using a small number of modular components. The specific requirements of a given project can be met by adding extra system components. For structural requirements, a range of profiles with different basic depths and/or internal reinforcing options are available; there is also a choice of appropriate accessories and infill units to suit different functions. The external appearance of the façade remains unaffected. Architects and designers are able to meet a range of thermal insulation, sound reduction and fire protection requirements while maintaining a uniform appearance. The small number of individual components facilitates warehouse storage and means that fabricators are soon familiar with the products. Various structural systems can be used to calculate the dimensions of steel façades (freely suspended, clamped on one side or continuous beams). Top and bottom fixing plates for building structure attachments can be easily and safely welded in place. Profiles with face widths of 50 and 60 mm and basic depths of up to 150 mm are available for the room-side load-bearing structure. They can be welded on or pushed on. Welded constructions mean that prefabrication in the workshop is an option even for large façades and roof glazing. Precision manufacture of complex units and unusual shapes is possible. Stick constructions can also be produced quickly and safely using connecting spigots. It is possible to combine both fabrication methods. The Jansen VISS façade systems have been successfully tested in accordance with the product standard EN 13830. On this basis, manufacturers can label façades with the CE mark which is obligatory throughout the EU. 5 VISS TV Weathertight right down the line The VISS TV profile system for large vertical façades has an exceptionally flat inner gasket, which is almost flush with the steel profile. This allows the beauty of slimline constructions to be fully appreciated. Steel profiles with a very small outer radius are the result of state-of-the-art production and world-famous Swiss precision. Through constant dialogue with designers, architects and fabricators, these steel profiles have been optimised to create a modular system which can be used to produce a wide range of different façades efficiently and cost-effectively using only a small number of individual components. High quality polyamide coupling studs guarantee reliable thermal breaking. Continuous gasket overlaps in the transom area allow field drainage and ventilation in the glazing rebate – even without cover profile preparation. Outer cover profiles are available in a range of depths and shapes. VISS TV meets the standards of the British Centre for Windows & Cladding Technology (CWCT) which are even more stringent than those of the DIN/EN norms. CWCT certification is recognised as a quality benchmark across Europe. 6 VISS TVS For the highest thermal insulation requirements This sealing system can be used with sloped or faceted glazing and for façades with higher insulation requirements. The horizontal or vertical gaskets lying on the same plane create a closed drainage level. Overlapping moulded gasket intersection points are bonded with special butyl seals; joint permeability and resistance to driving rain are certified up to 1200 P. An insulating core in the glazing rebate gives the high insulation façade VISS HI an outstanding Uf value of 0.7 W/m2K. In this way, the VISS TVS system makes a significant contribution to saving energy, making it best suited for the future. For vertical façades, the glazing rebate is drained and ventilated by field drainage and ventilation, whereas with sloped and roof glazing, the rafter base points are used. To ensure overall stability, we recommend welding for the manufacture of units. This allows a high degree of prefabrication with quality that can be controlled. Outer cover profiles are available in various depths and shapes which can also be bonded in the transom area of sloped glazing. 7 VISS Basic and VISS I x tra Gives shape to different load-bearing structures VISS Basic and laser-welded, sharp-edged VISS Ixtra profiles allow the sealing principle used in VISS TV and TVS constructions to be applied to any steel or stainless steel substructures. This means that you can select the tried and tested system construction, even for an existing load-bearing structure. This means a high degree of flexibility in design and for renovations, as well as system benefits, in particular the familiar simple and effective solutions provided by glazing rebate ventilation and drainage. VISS Basic Stainless steel bolts are used to fit a small number of individual components to the load-bearing structure; these bolts are welded or screwed to the structure. Infill units of 6 to 70 mm can be inserted. Outer cover profiles are available in a range of depths and shapes. VISS Ixtra 8 VISS SG Design enhanced by practical projected top-hung windows A high-tech façade in no time at all. Structural glazing, that is all-glass façades, are a growing trend in architecture. Thanks to the outstanding structural properties of steel, they can be constructed in the best possible way. Glazed areas of up to 2500 x 5000 mm can visibly increase the transparency of the building envelope. Various glass anchors allow the installation of double or triple insulating glass up to a unit thickness of 70 mm. The Jansen VISS SG system can be combined with any VISS profile with face widths of 50 and 60 mm and with the VISS Basic solution which can be mounted on any support. By adding the VISS SG projected top-hung window to the system, practical façade openings are seamlessly integrated into generous expanses of glass. Projected tophung windows can be flush-fitted in all-glass façades, or used with cover caps in mullion/transom façades. As they are fitted with double or triple glazing, this guarantees optimum thermal insulation and, with vent surface areas up to 4 m2 and a weight of up to 180 kg, provides attractive insert units for generously sized façades. 22 20 22 22 20 15 7.5 60 9 VISS Delta and VISS Linea Profiles for impressive steel façades Customers are attracted to these profiles with minimalist shapes which allow maximum light penetration to make interiors seem lighter – whether it be the elegant arrow-shaped VISS Delta or VISS Linea, the strong profile in the shape of a T-beam. VISS Delta With a face width of only 50 mm and a shape tapered towards the interior, the profiles have a particularly light and elegant look. Various adaptable reinforcements in the hollow profile section extend the possibilities for clear, structured steel façades. The systems use approved technology and can be combined with the tried-and-tested VISS constructions. VISS Linea 11 Profile range Load-bearing profiles 50 mm 2 2 2 60 17 50 50 50 76.671 76.671 Z 76.694 76.694 Z 17 50 17 50 17 80 2 80 2 80 50 76.096 76.094 76.696 76.696 Z 50 9 6 18 1.5 76.692 2.5 2.5 50 2 120 76.680 17 17 17 17 50 50 50 50 50 95 120 140 9 6 25 2.5 2.5 50 76.679 76.679 Z 76.697 76.697 Z 76.666 76.666 Z 76.105 9 6 25 1.5 76.682 15 15 15 70 2 175 2 60 35 95 2 150 x 15 120 95 15 145 120 x 15 15 50 50 50 76.114 76.115 76.116 12 2.5 2.5 25 25 25 2.5 50 76.131 50 50 76.132 76.133 205 180 x 15 15 Profile range Load-bearing profiles 60 mm 2.5 100 2 17 17 60 60 60 50 17 17 60 2 80 2 60 76.684 76.684 Z 76.678 76.678 Z 76.695 76.695 Z 76.095 60 9 6 18 1.5 76.693 2.75 2.5 2.5 60 120 150 150 9 6 25 1.5 17 17 17 60 60 60 76.698 76.698 Z 76.667 76.667 Z 50 76.683 60 76.100 9 6 25 2.5 76.681 Z = made from hot-dip galvanised steel strips, lightly oiled (275 g/m² zinc coating on both sides = approx. 20 µm zinc inside and outside) 13 Cover profiles 50 and 60 mm 50 Cover profiles 50 mm 50 50 50 18 12 10 47 407.860 407.800 25 50 407.863 407.862 407.861 90 50 5 90 50 1 2 18 18 33 31 13 15 3 50 407.914 407.864 407.900 407.911 50 3 19 50 407.818 6 10 8 407.817 11.7 14.5 22 19 8 8 50 12 30 50 407.823 407.821 407.858 Cover profiles 60 mm 60 60 57 18 12 407.866 407.865 1.5 407.867 120 10 407.802 25 6 60 60 3 14 60 23 407.901 407.868 407.915 14.5 18 8 31 13 50 60 23 407.859 Stainless steel cover profiles 50 and 60 mm 50 50 18 12 12 400.860 400.862 18 50 5 400.861 400.863 15 VISS TV Example of application B-B B-B 455.555 455.501 453.002 407.810 455.501 76.694 455.502 407.800 407.860 76.696 455.502 601.699.6 452.998 455.400 630.900 450.007 402.125 Z 455.501 407.860 407.001 407.800 455.400 450.047 76.696 455.502 5 455.410 Pressure compensation/ Drainage 407.860 407.810 76.694 452.470 407.800 455.555 455.501 76.696 452.470 Pressure compensation/ Drainage 455.502 455.555 452.464 76.696 16 A-A 76.696 76.696 76.694 76.696 76.694 5 407.800/407.860 407.800 407.800 407.861 407.861 452.464 601.699.6 455.513 455.501 135° inner corner detail Intermediate floor attachment detail 76.696 76 .6 96 76.694 76.696 407.800/407.860 407.800 1 86 7. 40 40 7 .8 76 00 .6 94 407.861 407.800/407.860 0 407.800 40 7. 80 0/ 40 7. 86 407.861 Examples of these new products in use are available as DXF files from www.jansen.com. 0 10 20 30 40 50 mm B A A B 17 VISS TVS (vertical) 76.115 Example of application C-C 76.115 76.697 407.818 D-D 407.811 407.818 76.682 455.501 455.502 601.699.6 601.699.6 452.998 76.697 407.818 630.900 402.125 Z 76.115 407.001 450.007 450.047 455.400 452.998 455.410 455.501 407.811 407.818 455.502 455.558 455.558 76.682 407.818 455.501 455.502 76.115 Examples of these new products in use are available as DXF files from www.jansen.com. 407.818 76.697 453.002 18 A-A 76.115 76.115 407.818 407.818 76.115 407.818 407.818 407.818 407.817 407.817 407.817 455.501 B-B 5 630.900 Z 5 402.125 Z 76.115 407.817 76.115 76.115 407.817 407.817 601.699.6 601.699.6 455.501 Alternative mullion profiles (laser-welded) 175 = 76.132 C 205 A A D B 145 B 76.131 76.133 D C 0 10 20 30 40 50 mm 407.800 407.800 407.861 407.861 19 VISS TVS (sloping) Example of application 550.424 A-A 452.292 20.270 407.302 455.110 407.861 452.465 407.301 452.295 452.465 407.800 455.506 28 26.220 407.815 455.537 455.501 76.096 407.861 76.696 76.694 76.696 407.800 455.502 455.539 453.002 76.694 407.811 76.096 452.470 452.465 76.696 Pressure compensation/ Drainage 20 Examples of these new products in use are available as DXF files from www.jansen.com. 40 7. 86 1 28 Alternative eaves detail with sheet metal frame 455.503 76 .6 96 45 5. 54 76 1 455.504 .6 96 407.815 Sheet metal casing B-B Pressure compensation/ Drainage 455.503 407.812 407.815 455.602 455.504 1 94 54 5. .0 76 45 452.495 453.007 7 407.815 6 .4 2 45 94 .6 76 453.007 94 .6 76 452.495 407.815 1 54 45 2. 5. 47 45 1 Pressure compensation/ Drainage .6 76 96 96 Cut-out in the area of rafter .6 76 B A 0 10 20 30 40 50 A mm B 21 28 VISS Basic TVS Example of application B-B 407.860 Welding stud (A-A) IPE 100 407.800 407.800 407.861 407.861 50 50 407.860 IPE 100 Screw bolt (A-A) 407.860 T 50/50/6 100x60x5 100x60x5 407.800 407.800 407.861 407.861 50 50 B UAP 100 407.860 A 0 10 20 30 40 50 mm 22 B A VISS I x tra TVS Example of application A-A Welding stud (A-A) 76.696 407.800 407.800 407.861 407.861 Screw bolt (A-A) 76.696 407.800 407.800 407.861 407.861 407.860 A B 0 B 10 20 30 40 50 mm A 23 VISS Fire No compromise on safety Universal fire-resistant façades. For the sensitive area of fire protection, Jansen has developed VISS Fire – a modular, fully insulated façade construction for universal use. The system is suitable for vertical façades in all fire resistance classes for interior and exterior use (E30/60/90, EI30/60/90 and E30 TVS). All modules are also TRAV safety tested. VISS Fire has also been tested and approved for use with Janisol 2 fire doors. The mullion/transom construction with a slender face width of 50 mm offers many design options. Basic depths from 50 to 140 mm provide a whole range of structural solutions for creating multi-storey façade units up to 5000 mm in height and unlimited width. The many alternatives give the designer the necessary freedom to create attractive large areas of glazing. The Delta and Linea load-bearing profiles can be used to make an elegant statement. 24 B-B A-A 76.696 76.694 76.696 76.696 Promatect H Steel sheet 2 mm 455.508 76.696 407.861 455.509 407.862 400.867 455.536 Aluminium sheet 2 mm Promatect H Alternative wall abutment 407.861 Ceramic fibre strip 452.472 76.694 Steel angle 80/40/6 455.509 76.696 76.694 76.696 452.488 76.694 407.861 Promatect H 407.862 400.867 Paneel F30 0 10 20 30 40 50 407.862 mm B 76.696 Promatect H Examples of these new products in use are available as DXF files from www.jansen.com. A A B 25 Performance characteristics Jansen VISS façades CE mark Thermal transmittance Curtain wall façade tested to EN 13830. The profile combinations were calculated according to EN ISO 10077-2. The product achieves UCW 0.7 W/m2K. Air permeability Bullet resistance Air permeability tested to EN 12152. The product achieves Class AE. Bullet resistance tested to EN 1522/1523. The product achieves Class FB4 NS. Watertightness Burglar resistance WK2 / WK3 Watertightness tested to EN 12154. The product achieves Class RE 1200. Burglar resistance tested to ENV 1627. The product achieves Class WK2 and on a project basis, WK3. Wind load resistance TRAV safety tested Wind load resistance tested to EN 13116. – Permissible wind load 2000 Pa – Safety loading 3000 Pa The product has been tested in accordance with the German TRAV regulations (technical regulations for the use of safety barrier glazing) and meets the requirements of category A. Impact resistance CWCT test Impact resistance tested to EN 14019. The product achieves Class E5 / I5. Tested to the requirements of CWCT. – Air permeability/ watertightness: PASS – Permissible wind load 2400 Pa – Safety loading 3600 Pa Sound insulation Sound insulation tested to EN ISO 140-3. The product achieves RW = 47 dB. 26 System versatility Janisol Basic depth of doors 60 mm Basic depth of windows 60/64 mm Janisol Primo Basic depth 60/64 mm Janisol Arte Basic depth 60 mm Janisol 2 Basic depth 60 mm Janisol C4 Basic depth 70 mm Safety and security Thermal insulation Fire protection Conservatories Partition walls Fixed glazing Façades Doors Systems Windows The right system for every application ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Systems specifications Doors and windows CE tested, anti-finger-trap door, folding wall, burglar resistance WK3 and bullet resistance, steel and stainless steel Windows CE tested, burglar resistance WK3 and bullet resistance Windows CE tested, inward and outwardopening windows, very slim face widths ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Doors and fixed glazing, fire resistance tested to EI30, smoke protection,burglar resistance, steel and stainless steel Doors and fixed glazing, fire resistance tested to EI60 and EI90, smoke protection ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ VISS Fire Face width 50 mm ◆ ◆ VISS SG Face width 50/60 mm ◆ ◆ ◆ ◆ Structural glazing façade based on the tried-and-tested VISS system ◆ ◆ ◆ Construction for steel and stainless steel façades for mounting on any support VISS TV Face width 50/60 mm VISS TVS Face width 50/60 mm VISS Basic / VISS Ixtra Jansen-Economy 50 Basic depth of doors 50 mm Basic depth of windows 50/58.5 mm Jansen-Economy 60 Basic depth 60 mm Standard profiles Basic depth 40, 50, 60, 80 mm Folding and sliding doors Basic depth: 50, 60, 80 mm ◆ Mullion-transom construction for vertical glazing, dry glazing, CE tested, burglar resistance WK3 and bullet resistance Mullion-transom construction for vertical and sloped glazing, dry glazing, CE tested, burglar resistance WK3 and bullet resistance Mullion-transom construction for vertical and sloped glazing, tested for fire resistance to E90/EI90 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Doors and windows CE tested, anti-finger-trap door, fire resistance tested to E30, smoke resistance, bullet resistance, steel and stainless steel Doors CE tested, anti-finger-trap door, fire resistance tested to E30, smoke resistance, burglar resistance and bullet resistance Hollow steel profile series for swing doors, pressed steel doors, horizontal pivot windows and pilaster profiles Hollow steel profile series for automatic or manual folding and sliding doors, CE tested 27 SW 598 240 / 05/2013 / Subject to change Jansen AG CH-9463 Oberriet SG [email protected] www.jansen.com
© Copyright 2024