Catalogue 2014 EPR/ESR Spectrometer Catalogue for EPR-Spectrometer, Accessories & Glassware Content Content EPR / ESR Spectrometer S. 3 I. What is new? ººBench Top EPR / ESR Spectrometer (Model# MS 5000) ººTechnical data ººWide field of applications ººKey features ººOptional functions (for MS 5000) 3 4 4 5 5 II. Temperature controllers ºº for MS 5000 ºº Autosampler add on (MS 5000) 5 5 III. Autosampler for MS 5000 6 6 IV. Goniometer (for MS 5000) 7 V. X-ray Unit 7 VI. Optical Stimulation Unit 7 VII. Optional packages for Special Applications using the MiniScope MS 5000 and MS 400 8 VIII.Standards 8 IX. Optional Software for Spectrometer of the Line MiniScope (MS 5000) 9 X. PC with monitor (Dell)9 Glassware S. 10 How to choose the appropriate Sample Vessel for your Sample 10 I. Standard Sample Holder 11 ºº Resonator Protection Tubes II. Sample Tubes and Closing Caps 11 III. Capillary measurements for liquid samples 12 ººGuidance Tubes ººCapillary and Sealing Kit IV. Accessories for temperature control and TC H03 11 ºº 12 12 12 Dewars13 V. Holder and accessories for alanine dosimetry Optional accessories: Sample Tubes for Dosimetry Tablets ºº ººOptional accessories: Blister Holders 2 11 13 13 13 VI. Sample Holders, Flat Cell Cuvette and Tissue Cells 14 VII. Flat Cell Cuvette 14 VIII.Sample storage 15 learn more about our technology and products on www.magnettech.de EPR/ESR Spectrometer What is new? Bench top EPR/ESR Spectrometer (Model# MS 5000) Module # 1000 compact size the ideal ‘everywhere’ spectrometer, can be handled by one person, low electricity power consumption 45 kg, 397 x 262 x 192 mm sensitivity & stability outstanding sensitivity and magnetic field stability, extended data detection schemes versatile options detection limit of 10 nM in PBS automated goniometer for measurement of angular dependencies, low temperature measurements, big collection of specialized sample holders and glassware, comfortable software for data handling and evaluation autosampling for liquids, powder and solid samples Facts Magnet system ººcompact, bench top spectrometer at highest sensitivity ººg-Factor representation of EPR spectra ººkinetic measurements, time resolution down to 2 µs ººexcellent field stability ººextremely stabel AFC (automatic frequency control), ººautomatic field readjustment according to microwave frequency ººextreme stability of all measurement parameters allowing for ns response time long range accumulation up to weeks RF system and signal channel measurement frequency stability better +/- 3 Hz @ 10 GHz 3 EPR/ESR Spectrometer Technical data Magnetic field Microwave field modulation 1 μT – 1 mT frequency 9.2 – 9.6 GHz modulation frequency 100 kHz power 1 μW – 100 mW magnetic field range 5 - 650 mT resonator rectangular TE 102. Automatic detection of Q factor. field resolution 0.03 µT sensitivity 8 x 109 spins / 0.1 mT scan range 0 – 645 mT case size 397 x 262 x 192 mm scan resolution 120,000 steps weight ~ 45 kg stability 1.5 µT / min, 10 µT / h power consumption ~ 300 VA homogeneity + 5 μT within sample region sweep time 1 s – 2 h cooling air if necessary (low sound) Wide field of applications Life sciences Food Chemistry and Pharmacy Petrochemistry Nitric oxide measurement, reactive oxygen Antioxidative features of foodstuff, Living polymers, nitroxide quantification, species, oxidative stress, radical generating radicals in foodstuff, radiation-induced radicals in varnish, UV stability of scratch systems, photo dynamic therapy radicals resistant varnish Environmental Toxicology Alanine Dosimetry Separation of Radicals Generation of radicals by particles Alanine dosimetry (tablets, thin films) EPR/HPLC coupling Biophysical Features Bioinorganic Chemistry Cosmetic Oxymetry, membrane fluidity, pH in Bioinorganic transition metal com- Radical protection factor, protection microenvironment, viscosity, phase pounds, fenton chemistry, effect of features of UV-filters in creme, sham- partition heavy metal ions on living tissue poo, etc. Kinetic of ROS generation by xanthine / xanthine oxidase 4 Basal (black) and stimulated (blue) NO generation by rat aorta TEMPOL in a two phase system oil/water learn more about our technology and products on www.magnettech.de Spectrum of an Alanine tablet irradated with 5 Gy Key Features MiniScope MS5000 Large Spectrometer 3 3 4 .8 3 3 5 .8 3 3 6 .8 3 3 7 .8 3 3 8 .8 M ag n etic F ield S tren g th [m T ] 100 µM TEMPOL SOD mimetic Cu (II) complex NO-Hemoglobin Weak pitch: P = 12 mW, modulation = 0.2 mT Detection limit available Standards Ultra fast and stable Sensitivity of MS 5000 10 µM in PBS Chromium and Manganese auto frequency control bench top spectrometer Wide magnetic field range No spikes due to liquid (650 mT) nitrogen bubbles Optional functions (for MS 5000) Extended RF Power range Module # 1011 10 µW – 100 mW Recommended for samples saturating at microwave power higher than 50 mW and for measurements with microwave power less than 100 µW. Extended Magnetic Field range compared to large stationary spectrometer with universal TE 102 cavity II. Temperature controllers for MS 5000 Bio Temperature Controller Module # 1102 For temperature stabilization of biological systems like tissue samples. Temperature range: 290 K – 323 K Module # 1012 50 – 600 mT air cooled The increase of magnetic field range is recommended to measure transition metal complexes of Fe(III) low spin. The extension includes a compact refrigerated circulator with 240 W cooling Vessel for flushing resonator Module # 1103 Liquid nitrogen evaporates, flushing resonator and preventing the condensation of humidity, optional accessory in connection with fixed temperature dewar. capacity. g factor Evaluation, Module # 1013 including Frequency Counter ººFrequency range: 0.5 to 10.0 GHz ººInput level: -5 to +10 dBm, 50 Ohms ººDisplay: 7 digits, 1 kHz resolution ººConnector: SMA female, back panel 5 EPR/ESR Spectrometer Temperature Controller TC H03 Module # 1104 Autosampler for Liquids down to 1 ml incl. Table Suitable for 23 liquid samples and Temperature range: 103 K – 473 K cleaning liquid. PC controlled (control / registration software included) Automatic liquid sample transfer for Optional: Software for automatic data acquisition for spectrometers of the MiniScope series, temperature measurements. Autosampler and integrated peristaltic Module # 1203 pump, software controlled. Software for kinetic measurements, including automatic data acquisition and data evaluation. Single or multiple chemi cals, optional: automa ted component mixing and temperature control. III. Autosampler for MS 5000 (select one) Autosampler for powder and Autosampler add on (MS 5000) Module # 1201 solid samples Two pump system, automated handling of up to Reaction Chamber Module # 1204 23 samples in quarz tubes 3 – 6 mm diameter, precise Autosampler Rack height positioning within for continuous flow systems Module # 1205 resonator for highest Peristaltic Pump reproducibility. Module # 1206 Very uniform pump behaviour, suitable for kinetics measurements. Autosampler for Liquids up to 43 ml Module # 1202 Thermostat Block Module # 1207 Suitable for 14 liquid samples and Max. temperature 130° C cleaning liquid. ººAdapted sample tubes for optimum heat transition ººInterchangeable metal block for different sample vessels Automatic liquid sample transfer for spectrometers of the MiniScope series, Autosampler and integrated peristaltic Autosampler for special pump, software con trolled. Software applications for kinetic measurements, Suitable for beer quality and including automatic data shelf time analysis acquisition and data evaluation. Single or multiple chemicals, optional: automated component mixing and temperature control. 6 learn more about our technology and products on www.magnettech.de Module # 1208 IV. Goniometer (for MS 5000) Automated loading of Automated Goniometer ºº Module # 1300 Module # 1401 X-ray Source Fully automated angular rotation of sample ººStep size 0,1 to 180° ººEach measurement of a new spectrum starts with an auto- mated readjustment of the spectrometer for best measurement performance Ionization Chamber for Module # 1402 X-ray dose measurements fully integrated dose measurement for precise monitoring of X-ray irradiation intensity Automated Goniometer Module # 1301 for Autosampler ººFully automated angular rotation of sample with special adaptations for Autosampler ººStep size 0,1 to 180° ººEach measurement of a new spectrum starts with an auto- mated readjustment of the spectrometer for best measurement performance VI. Optical Stimulation Unit Integrated Light Source Module # 1501 For sample treatment or for triggering kinetic experiments. V. X-ray Unit X-ray Source ºº Module # 1400 fully automated 50 kV External Irradiation Unit: X-ray tube at a focal spot Halogen Lamp (Hamamatsu) size of 1 mm Wavelength range: 240 – 700 nm, depend of the lamp inclusive ººHigh voltage generator ººShielding integrated Module # 1502 light guide adapter at the MiniScope (additional wavelengths available on request) 7 EPR/ESR Spectrometer VII. Optional packages for Special Applications using the MiniScope Reactive Oxygen Species (ROS) MS 5000 and MS 400 Consisting of: Alanine Dosimetry ººFlat cell cuvette FZK 160-7x0.3 ººSpecial holder SH-P for flat cell cuvettes, guidance tubes, Module # 1601 Consisting of: ººSpecial holder SH-P ººSpecial cuvette FFZK 130-4,5x0.8 for dosimetry thin film test strips Module # 1603 tissue cells and special cuvettes ººFixed holder with fitting for flat cell cuvettes FZK 160-7x0.3 ººFixed holder with fitting for guidance tube F 120 / 1.5 ººOptional: Software for automatic data acquisition and evaluation of kinetic measurements using disposable glass capillaries. ººHolder for precise sample positioning with Includes: adjustable altitude ºº2 Tubes for dosimetry tablets with inner diameter 4701, 4601, 4602 4,0 mm or 4,8 mm ººOptional: Software for dose calculation against a reference (Aerial Company). Price upon request. Includes: 4601, 4704, 4101, 4701, 4606 VIII. Standards Holder and positioning system Module # 1701 for Standard Samples (MS 5000) NO-Fe(II)DETC (Fixed temperature Module # 1602 dewar for N2 liquid) MT Weak pitch Cr in MgO Consisting of: ººFixed temperature dewar for spectrometer of the line MiniScope ººHolder fit to the device with adjustable altitude for fixed temperature ººdewar suitable for MiniScopes Includes: 4606 8 learn more about our technology and products on www.magnettech.de Module # 1702 # ???? Secondary standard Chromium Module # 1703 Automated data evaluation, Module # 1804 Cr3+ in MgO angular dependent peak evaluation With protocol on g-factor An example showing angular dependent measurements with Goniometer. Evaluation of peak position vs. angle. Different spot sizes mark different peak intensities on a ln-scale. Secondary standard Manganese Module # 1704 Mn2+ in ZnS Software capability for storage of With protocol on g-factor and peak distances Module # 1805 calibration curves for quantitative measurements and dosimetry X. PC with monitor (Dell) PC with monitor (Dell) Module # 3000 IX. Optional Software for Spectrometer of the Line MiniScope (MS 5000) Automatic data acquisition and Module # 1801 evaluation for kinetic measurements Sequence editor for free Module # 1803 programming of automation functionality 9 Glassware Glassware How to choose the appropriate sample vessel for In the case you use organic solvents with a lower dielectric constant; your sample? you can use capillaries with a higher volume or sample tubes. For measurement of samples in the EPR spectrometer you have the choice between the following sample vessels: Sample tubes are used for liquid and solid samples. We offer ººCapillary ººSample tube ººFlat cell ººTissue cell ººSpecial cuvette ººFixed temperature dewar sample tubes of different diameters and length. The dielectric Some general remarks fer. In the case a sample is not tunable you can either choose a The active volume in the vertical direction of the MiniScope rect- sample tube with a smaller diameter or you reduce the amount angular resonator is 23 mm. Over this 23 mm you have a Gauss of sample inserted into the resonator. constant of the solvent of your liquid sample lays down the dia meter of the sample tube. For example radicals in hydrocarbons can be measures using a 4 mm or 5 mm sample tube. Concer ning the solid samples the humidity of the sample restricts the diameter of the sample tube. The length 135 mm is used in gene ral. The length 240 mm is adapted to the finger dewars, we of- distribution of the intensity. This means in the centre you measure 100 % intensity. 1.65 mm top and bottom of the centre Flat cells are used for liquid samples in solvents with a high the intensity is 95 %. 2.5 mm top and bottom of the centre the dielectric constant. The ideal sample distribution in the resonator intensity is 90 %. This means you have two possibilities to get leads to a 2 – 2.5 fold higher intensity compared to 50 μl capilla reproducible and comparable measurements: ries. The crucial point, when using a flat cell is the orientation of the flat section, the vertical position and the filled volume of the [1] You fill the sample vessel over the whole active volume of the resonator. flat cell. Therefore we recommend using the special holder SH-P as the system to achieve always the same sample positioning. [2] You fill 5 mm of your sample vessel. In this case you have to make sure that the sample is positioned absolutely in the Tissue cells can be used to measure skin sections, paste and centre of the resonator. A further requirement is that in the emulsions. The same requirements have to be fulfilled that are case you are using different sample vessels of the same kind, valid for flat cells. that they are selected for the same intensity or that you have compared them using a standard solution introducing correc- A special cuvette we offer for alanine dosimetry of thin film tion factors. test strips. This cuvette has a flat section too. Furthermore we offer special tubes for alanine tablet dosimeters. In the case you are using sample vessels with a flat section you can orientate the flat section parallel or perpendicular to the Fixed temperature dewars are used to measure samples front panel of your spectrometer. Please try, which orientation at liquid nitrogen temperature of 77 K. You can either drop the gives the higher intensity. sample into the liquid nitrogen and the frozen drops are collected in the finger for measurement. Capillaries are standardized calibrated sample vessels. They are A further possibility is to freeze a cylinder of 4 mm diameter cheap one way items and allow an easy sample exchange. Usually matching to the size of the inner finger of the dewar. In the case capillaries are used together with a matching guidance tube. For you like to measure solid samples you can use sample tubes of 3 aqueous solutions the maximum volume of capillaries is 50 μl. or 4 mm outer diameter and 240 mm length. 10 learn more about our technology and products on www.magnettech.de I. Standard Sample Holder II. Sample Tubes and Closing Caps For the alignment of sample tube within the standard sample holder for ESR measurements. Sample tube, Module # 4300 synthetic quartz P 165 / 3 Length: 165 mm, Outer diameter: 3 mm, Wall thickness: 0.7 mm (Requires Module # 4200) PH-3 for sample tubes 3 mm Module # 4200 PH-3.6 for guidance tubes 3.6 mm Module # 4201 PH-4 for sample tubes 4 mm Module # 4202 (Requires Module # 4202) PH-5 for sample tubes 5 mm Module # 4203 Sample tube, Sample tube, Module # 4301 synthetic quartz P 165 / 4 Length: 165 mm, Outer diameter: 4 mm, Wall thickness: 0.7 mm Module # 4302 synthetic quartz P 165 / 5 PH-6 for sample tubes 6 mm Module # 4204 autosampler tube grip Module # 4205 Length: 165 mm, Outer diameter: 5 mm, Wall thickness: 0.7 mm (Requires Module # 4203) for sample tubes 3 mm Sample tube, Other sizes are available on request synthetic quartz P 165 / 6 Module # 4303 Length: 165 mm, Outer diameter: 6 mm, Wall thickness: 0.7 mm (Requires Module # 4204) 1 Set closing caps 4 mm Module # 4310 (50 pieces) Resonator protection tubes Resonator protection tube Module # 4003 1 Set closing caps 5 mm Module # 4311 (50 pieces) 11 Glassware III. Capillary measurements IV. Accessories for temperature for liquid samples control and TC H03 Guidance tubes Holder fit to the device with Module # 4100 adjustable altitude for fixed Guidance Tube F-120 / 1.5 Module # 4005 # 4002 temperature dewar suitable for MiniScopes. To geometrically align the capillary in the center of the resonator. See # 4009, requires # 4200 Capillary and Sealing Kit Disposable glass capillaries 50 µl, Guidance Tube F-120 / 1.5T Module # 4006 Sample Holder for TC H02 Module # 4102 Module # 4009 250 pieces Volume 50 μl with ring, accuracy < +/- 0.25 %, precision < 0.5 % and TC H03 (Top) (capillaries with smaller volumes are available upon request) Sealing kit for disposable glass Module # 4010 capillaries None drying out vinyl kit on one plastic plate for secure sealing of more than 75 capillaries 12 Sample Holder for TC H02 and TC H03 (Bottom) learn more about our technology and products on www.magnettech.de Module # 4103 V. Holder and accessories Resonator Dewar for Temperature Module # 4104 Controller TC H02 and TC H03 for alanine dosimetry Holder for precise sample Module # 4000 positioning with adjustable altitude (e.g. alanine tablets) Also see Special Holder: Module # 4500 Resonator Dewar for Bio Module # 4105 Temperature Controller BTC 01 and BGC 01 Optional accessories Sample Tubes for Dosimetry Tablets For alignment of dosimetry tablets Type 1: Inner diameter 4,0 mm Module # 4001 Type 2: Inner diameter 4,8 mm Module # 4002 Dewars To manually cool the samples Dewars for spectrometer Module # 4130 of the line MiniScope Volume 50 ml ºº ººOuter finger: outer diameter 10.5 mm, length 178 mm ººInner finger: inner diameter 5.4 mm, length 105 mm ººStorage time 2 h Blister Holders Models with larger volume and different sizes of the finger upon request. Blister Holder, Type S Module # 4601 13 Glassware VI. Sample Holders, Flat Cell Cuvette and Tissue Cells VII. Flat Cell Cuvette For Aqueous solutions Special holder SH-P for flat Module # 4500 Flat cell cuvette FZK 160-7x0.3 cell cuvettes, guidance tubes, Width of flat section 7.0 mm, tissue cells and special cuvettes width of gap 0.3 mm Module # 4502 One fixed holder with fitting (separately available too, see below), especially adapted as one chooses one of the following sample vessels: ººFlat cell cuvette FZK 160 ººFlat cell cuvette FZK 200 ººGuidance tube F-120 / 1,5 ººTissue cell GZ 170 ººSpecial cuvette FFZK 130-4,5x0,8 ººHolder mounted at the device with fixation and protection Flat cell cuvette FZK 200-5x0.3 Module # 4503 Width of flat section 5.0 mm, width of gap 0.3 mm, including 5 closing caps 5 mm tube for spectrometer of the line MiniScope allows a definite sample exchange Flat cell cuvette FZKV 200-7x0.3 Module # 4504 Width of flat section 7.0 mm, width of gap 0.3 mm Fixed holder with fitting for flat Module # 4501 cell cuvettes, guidance tubes, tissue cells and special cuvettes Especially adapted to the following sample vessels: ººFlat cell cuvette FZK 160 ººFlat cell cuvette FZK 200 ººGuidance tube F-120 / 1,5 ººTissue cell GZ 170 ººSpecial cuvette FFZK 130-4,5x0,8 Adapted to special holder SH-P Special cuvette FFZK 130-4,5x0.8 Module # 4505 for dosimetry test strips The special cuvette consists of a tube of 95 mm length, whose bottom end has a flat part of a length of 35 mm with one open side and a gap of 0.8 mm. The width of the flat section and the inner diameter of the tube can be chosen in dependency on the width of the test strip. For exact positioning of the cuvette we recommend our special holder SH-P. 14 learn more about our technology and products on www.magnettech.de VIII. Sample storage Tissue Cells Sample storage For tissue samples Module # 4700 Recommended for safe and organized storage of sample tubes The tissue cell consists of a flat part (sample holder) with the dimensions 65 x 7 x 2 mm having two holders in axial direction (bottom length of holder 20 mm, upper length 85 mm). The flat part has a milled deepening (length 30 mm, width 5 mm, depth in general 0.3 mm) which serves to hold the sample. The delivery includes one cover slide and two clamps for fixing the cover slide. Additional cover slides and clamps can be ordered separately. Tissue cell GZ 170-5.0x0.3 Module # 4506 Width of deepening 5.0 mm, depth 0.3 mm Tissue cell GZ 170-5.0x0.5 Module # 4507 Width of deepening 5.0 mm, depth 0.5 mm 1 Cover slide for tissue cell GZ 170 Module # 4508 1 set (2 pcs.) clamps Module # 4509 for cover slide of tissue cell Tissue Cell GZ 170P Module # 4510 (Plastic) Material: plastic POM / PTFE. For fast and simple sample exchange for series measurements. The tissue cell consists of a flat part (sample holder) with the dimensions 50 x 5 x 2 mm having two holders in axial direction. The flat part has a milled deepening with dimensions 13 x 5,8 mm, depth 0,2 mm and a additional deepening with diameter 5,8 mm, depth 1 mm. 15 Freiberg Instruments Competence in metrology Freiberg Instruments is a specialised manufacturer for research and production characterisation equipment Inline Metrology (PV/microelectronics) OSL/TL reader “lexsyg” In- and offline tools for semiconductor defect recognition and steady state or µPCD carrier lifetime measurements with fast decays down to below 100 ns Versatile research equipment for optically and thermally stimulated luminescence applications. Including PMT measurements, spectroscopic and camera (EMCCD) options. For dating applications, dosimetry and beyond MDPinline ingot lexsygresearch Contact Sales office: by Freiberg Instruments Production and R&D: magnettech GmbH Freiberg Instruments GmbH Louis-Blériot-Str. 5 Delfter Str. 6 D-12487 Berlin, Germany D-09599 Freiberg, Germany Phone: +49 30 6780 2526 Phone: +49 3731 419540 Fax: Fax: +49 30 6322 4101 +49 3731 4195414 E-Mail:[email protected] E-Mail:[email protected] www.magnettech.de www.freiberginstruments.com lexsygsmart
© Copyright 2024