Model: 800REOZDD 380--600 V Diesel Standard Features D Kohler Co. provides one-source responsibility for the generating system and accessories. D The generator set and its components are prototype-tested, factory-built, and production-tested. D The 60 Hz generator set offers a UL 2200 listing. D The generator set accepts rated load in one step. D The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. D The generator set complies with ISO 8528-5, Class G3, requirements for transient performance. D The 60 Hz generator set engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 2 nonroad emissions regulations. D A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available. D Alternator features: d The pilot-excited, permanent magnet (PM) alternator provides superior short-circuit capability. d The brushless, rotating-field alternator has broadrange reconnectability. D Other features: d Controllers are available for all applications. See controller features inside. d Electronic engine controls and a generator set microprocessor controller combine to deliver one of the most advanced control systems in today’s market. Ratings Range Standby: Prime: kW kVA kW kVA 60 Hz 725--800 906--1000 680--725 850--906 50 Hz 584--696 730--870 528--632 660--790 Generator Set Ratings Alternator 5M4034 5M4036 5M4038 5M4166 5M4278 Voltage Ph Hz 150_C Rise Standby Rating kW/kVA Amps 240/416 277/480 220/380 230/400 240/416 240/416 277/480 220/380 230/400 240/416 240/416 277/480 220/380 230/400 240/416 220/380 347/600 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 60 60 50 50 50 60 60 50 50 50 60 60 50 50 50 60 60 725/906 790/988 652/815 632/790 604/755 795/994 795/944 688/860 688/860 668/835 800/1000 800/1000 696/870 696/870 696/870 800/1000 800/1000 1258 1188 1238 1140 1048 1379 1195 1307 1241 1159 1388 1203 1322 1256 1207 1519 962 130_C Rise Standby Rating kW/kVA Amps 125_C Rise Prime Rating kW/kVA Amps 105_C Rise Prime Rating kW/kVA Amps 725/906 750/938 640/800 612/765 584/730 785/981 795/994 652/815 688/860 640/800 800/1000 800/1000 696/870 696/870 696/870 800/1000 800/1000 680/850 720/900 600/750 600/750 552/690 720/900 720/900 624/780 624/780 624/780 725/906 725/906 632/790 632/790 632/790 725/906 725/906 680/850 710/888 588/735 560/700 528/660 720/900 720/900 612/765 624/780 584/730 725/906 725/906 632/790 632/790 632/790 725/906 725/906 1258 1128 1215 1104 1013 1362 1195 1238 1241 1110 1388 1203 1322 1256 1207 1519 962 1180 1083 1140 1083 958 1249 1083 1185 1126 1083 1258 1090 1200 1140 1096 1377 872 1180 1067 1117 1010 916 1249 1083 1162 1126 1013 1258 1090 1200 1140 1096 1377 872 RATINGS: All three-phase units are rated at 0.8 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. Prime Power Ratings: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. Obtain the technical information bulletin (TIB-101) on ratings guidelines for the complete ratings definitions. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 1.0% per 100 m (328 ft.) elevation above 400 m (1312 ft.). Temperature: Derate 3.0% per 5.0_C (9_F) temperature above 40_C (104_F). G5-334 (800REOZDD) 8/10f Alternator Specifications Specifications Alternator Type Exciter type 4-Pole, Rotating-Field Brushless, PermanentMagnet Pilot Exciter 10, Reconnectable Solid-State, Volts/Hz NEMA MG1 Class H, Synthetic, Nonhygroscopic 130_C, 150_C Standby 1, Sealed Flexible Disc Full 125% 125% Leads: quantity, type Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Rotor balancing Rotor balancing Voltage regulation, no-load to full-load (with < 0.5% drift due to temp. variation) 3-Phase Sensing, ±0.25% One-step load acceptance at 60 Hz 100% of Rating Unbalanced load capability 100% of Rated Standby Current Peak motor starting kVA: (35% dip for voltages below) 480 V 5M4034 (10 lead) 2600 (60 Hz), 2000 (50 Hz) 480 V 5M4036 (10 lead) 3200 (60 Hz), 2400 (50 Hz) 480 V 5M4038 (4 lead) 3050 (60 Hz), 2350 (50 Hz) 380 V 5M4166 (4 lead) 2700 (60 Hz) 600 V 5M4278 (4 lead) 3450 (60 Hz) D NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. D Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. D Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. D Self-ventilated and dripproof construction. D Superior voltage waveform from two-thirds pitch windings and skewed stator. D Digital solid-state, volts-per-hertz voltage regulator with ±0.25% no-load to full-load regulation. D Brushless alternator with brushless pilot exciter for excellent load response. Application Data Engine Engine Electrical Engine Specifications 60 Hz Manufacturer Engine: model Engine: type Cylinder arrangement Displacement, L (cu. in.) Bore and stroke, mm (in.) Compression ratio Piston speed, m/min. (ft./min.) Main bearings: quantity, type Rated rpm Max. power at rated rpm, kWm (BHP) Cylinder head material Crankshaft material Valve (exhaust) material Governor: type, make/model Frequency regulation, no-load to-full load Frequency regulation, steady state Frequency Air cleaner type, all models 50 Hz Detroit Diesel/MTU 12V2000 12V2000 G85 G65 R123-8A37 R123-8A38 4-Cycle, Turbocharged, Intercooled 12-V 23.9 (1458) 130 x 150 (5.12 x 5.91) 16.0:1 540 (1772) 7, Precision Half Shells 1800 1500 890 (1194) 765 (1026) Cast Iron Forged Steel Austenitic Steel ADEC Electronic Control Isochronous ±0.25% Fixed Dry Exhaust Exhaust System m3/min. Exhaust flow at rated kW, (cfm) Exhaust temperature at rated kW, dry exhaust, _C (_F) Maximum allowable back pressure, kPa (in. Hg) Exh. outlet size at eng. hookup, mm (in.) 60 Hz 50 Hz 174 (6145) 123 (4344) 580 (1076) 565 (1049) Engine Electrical System Battery charging alternator: Ground (negative/positive) Volts (DC) Ampere rating Starter motor rated voltage (DC) Battery, recommended cold cranking amps (CCA): Qty., CCA rating each Battery voltage (DC) 60 Hz 50 Hz Negative 24 70 24 Two, 1150 12 Fuel Fuel System Fuel supply line, min. ID, mm (in.) Fuel return line, min. ID, mm (in.) Max. fuel flow, Lph (gph) Min./max. fuel pressure at engine supply connection, kPa (in. Hg) Fuel filter: quantity, type Recommended fuel 60 Hz 50 Hz 12 (0.5) 6 (0.25) 480 (127) --30/50 (--8.8/14.8) 1, Secondary #2 Diesel Lubrication Lubricating System Type Oil pan capacity dipstick mark max., L (qt.) Oil pan capacity, initial filling, L (qt.) Oil filter: quantity, type Oil cooler 8.5 (2.5) See ADV drawing G5-334 (800REOZDD) 8/10f 60 Hz 50 Hz Full Pressure 67 (71) 77 (81) 2, Cartridge Water-Cooled Application Data Cooling Radiator System Ambient temperature, _C (_F)* Engine water capacity, L (gal.) Radiator system capacity, including engine, L (gal.) Engine jacket water flow, Lpm (gpm) Charge cooler water flow, Lpm (gpm) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) Heat rejected to charge cooling water at rated kW, dry exhaust, kW (Btu/min.) Water pump type Fan diameter, including blades, mm (in.) Fan, kWm (HP) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H2O) High Ambient Radiator System Ambient temperature, _C (_F)* Engine jacket water capacity, L (gal.) Radiator system capacity, including engine, L (gal.) Engine jacket water flow, Lpm (gpm) Charge cooler water flow, Lpm (gpm) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) Heat rejected to charge cooling water at rated kW, dry exhaust, kW (Btu/min.) Water pump type Fan diameter, including blades, mm (in.) Fan, kWm (HP) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H2O) Fuel Consumption 60 Hz 50 Hz 40 (104) 130 (34) 288 (76) 833 (220) 667 (176) 258 (68) 233 (62) 315 (17930) 305 (17360) 270 (15368) 185 (10530) Centrifugal 1372 (54) 34 (46) 20 (27) 50 Hz Standby Rating 219.6 (58.0) 183.4 (48.4) 165.5 (43.7) 136.8 (36.2) 111.9 (29.6) 93.9 (24.8) 60.9 (16.1) 51.2 (13.5) Diesel, Lph (gph) at % load 100% 75% 50% 25% Prime Rating 199.9 (52.8) 165.8 (43.8) 150.6 (39.8) 124.9 (33.0) 101.9 (26.9) 86.2 (22.8) 56.7 (15.0) 47.2 (12.5) Controllers 0.125 (0.5) 60 Hz 50 Hz 50 (122) 130 (34) 310 (82) 833 (220) 667 (176) 258 (68) 233 (62) 315 (17930) 305 (17360) Decision-Makerr 3+ Controller Provides system control and monitoring capabilities. D Analog display using AC meters, engine gauges, and voltage selector switch. D 16-light status, warning, and shutdown fault annunciation. D Alarm horn, emergency stop switch, and hour meter features. D Remote annunciation options. D Remote start and prime power options. Refer to G6-30 for additional controller features and accessories. 270 (15368) 185 (10530) Centrifugal 1524 (60) 43 (58) 25 (34) 0.125 (0.5) * Enclosure with enclosed silencer reduces ambient temperature capability by 5°C (9°F). Remote Radiator System[ 60 Hz Diesel, Lph (gph) at % load 100% 75% 50% 25% 60 Hz Exhaust manifold type Connection sizes: Water inlet/outlet, mm (in.) Intercooler inlet/outlet, mm (in.) Static head allowable above engine, kPa (ft. H2O) 50 Hz Dry 77 (3) 51 (2) 149 (50) [ Contact your local distributor for cooling system options and specifications based on your specific requirements. Decision-Makerr 550 Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities. D Digital display and keypad provide easy local data access D Measurements are selectable in metric or English units D Remote communication thru a PC via network or modem configuration D Controller supports Modbusr protocol D Integrated voltage regulator with ±0.25% regulation D Built-in alternator thermal overload protection D NFPA 110 Level 1 capability Refer to G6-46 for additional controller features and accessories. Operation Requirements Air Requirements 60 Hz 50 Hz Radiator-cooled cooling air, m3/min. (scfm)] 983 (34717) 780 (27551) High ambient radiator-cooled cooling air, m3/min. (scfm)] 1218 (43022) 958 (33832) Cooling air required for generator set when equipped with city water cooling or remote radiator, based on 14_C (25_F) rise, m3/min. (scfm)] 311 (11000) Combustion air, m3/min. (cfm) 66 (2330) 54 (1907) Heat rejected to ambient air: Engine, kW (Btu/min.) 40 (2275) Alternator, kW (Btu/min.) 47 (2673) ] Air density = 1.20 kg/m3 (0.075 lbm/ft3) Decision-Makerr 6000 Paralleling Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities for paralleling multiple generator sets. D Paralleling capability with first-on logic, synchronizer, kW and kVAR load sharing, and protective relays D Digital display and keypad provide easy local data access D Measurements are selectable in metric or English units D Remote communication thru a PC via network or modem configuration D Controller supports Modbusr protocol D Integrated voltage regulator with ±0.25% regulation D Built-in alternator thermal overload protection D NFPA 110 Level 1 capability Refer to G6-107 for additional controller features and accessories. G5-334 (800REOZDD) 8/10f KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Additional Standard Features - Line Circuit Breaker with Shunt Trip (NEMA type 1 enclosure) - Safeguard Breaker (Decision-Makerr 3+ controller only) D Alternator Protection (standard with Decision-Makerr 550 and 6000 controllers) D Engine Closed Crankcase Breather D Oil Drain Extension D Operation and Installation Literature D Radiator Duct Flange D Reactive Droop Compensation (standard with Decision-Makerr 550 and 6000 controllers) Paralleling System - Decision-Makerr Paralleling System (DPS) (Decision-Makerr 6000 controller only) - Manual Speed Adjust Control - Reactive Droop Compensator (Decision-Makerr 3+ controller only) - Remote Voltage Adjustment Control - Voltage Regulator Relocation (Decision-Makerr 3+ controller only) Available Options - Approvals and Listings CSA Approval IBC Seismic Certification Rated Power Factor Testing UL 2200 Listing Enclosed Unit - Sound Enclosure/Fuel Tank Package - Weather Enclosure/Fuel Tank Package Open Unit - Exhaust Silencer, Critical (kits: PA-354880, qty. 2, PA-354898 qty. 1, or PA-354894 qty. 1) - Exhaust Silencer, Hospital (kits: PA-354905 qty. 2, PA-354912 qty. 1, or PA-354907 qty. 1) - Flexible Exhaust Connector, Stainless Steel Fuel System - Flexible Fuel Lines - Fuel Pressure Gauge - Fuel/Water Separator Miscellaneous Air Cleaner, Heavy Duty Air Cleaner Restriction Indicator Integral Vibration Isolation Mounting Solid Mounting/Spring Isolators - Literature General Maintenance NFPA 110 Overhaul Production - Warranty 2-Year Basic 2-Year Prime 5-Year Basic 5-Year Comprehensive 10-Year Major Components Other Options - _______________________________________________ - _______________________________________________ - _______________________________________________ Controller - Common Failure Relay - Communication Products and PC Software (Decision-Makerr 550 and 6000 controllers) - Customer Connection (Decision-Makerr 3+ and 550 controllers) - Dry Contact (isolated alarm) - Prime Power Switch (Decision-Makerr 550 and 6000 controllers) - Remote Audiovisual Alarm Panel - Remote Emergency Stop - Remote Mounting Cable (Decision-Makerr 3+ and 550 controllers) - Remote Serial Annunciator Panel - Run Relay Dimensions and Weights Overall Size, max., L x W x H, mm (in.): Weight, radiator model, max. wet, kg (lb.): 4403 x 1929 x 2386 (173.3 x 75.9 x 93.9) 6123 (13500) H Cooling System - Block Heater (includes isolation valves); Recommended for Ambient Temperatures Below 10°C (50°F) - High Ambient Radiator - Remote Radiator Cooling Setup - - W L NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information. DISTRIBUTED BY: Electrical System Alternator Strip Heater Battery Battery Charger, Equalize/Float Type Battery Heater Battery Rack and Cables Bus Bar (standard on 7M alternators, 380--600 volt only) Line Circuit Breaker (NEMA type 1 enclosure) © 2008, 2009, 2010 by Kohler Co. All rights reserved. G5-334 (800REOZDD) 8/10f
© Copyright 2024