The Pivotrol® Pump Patented Selection and Sizing How to Select and Size Capacity lb/h When installed with recommended filling head above top of pump. Non-Electric Pumps Condensate Recovery From the inlet pressure, back pressure and filling head conditions given below, select the pump size and check valve package which meets the capacity requirement of the application. Specify pump body, type PTC or PTF. Select optional extras as required. For GPM, multiply the capacities below by 0.002. For kg/h, multiply the capacities below by 0.454. For liquid specific gravities from 0.9 to 0.65, consult Spirax Sarco. * Back pressure is the lift height (H) in feet x 0.433 plus psig in return line, plus downstream piping friction pressure drop in psig calculated based on the maximum instantaneous discharge rate of te respective pump selected. (See TIS Sheets) Note: To achieve rated capacity, pump must be installed with check valves supplied by Spirax Sarco. Use of a substitute check valve may effect the performance of the pump. Condensate load7000 lb/h Steam pressure available for operating pump 80 psig Vertical lift from pump to the return piping 30 feet Pressure in the return piping (piping friction negligible 25 psig Filling head on the pump available 12 inches Solution: 1.Calculate "H", the totallift or back pressure, against which the condensate must be pumped. = (30 x 0.433) + 25=38 psig 2.From capacity table, with 80 psig inlet pressure and 40 psig back pressure, choose a 2" x 2" pump with stainless steel check valves, which ha a capacity of 6,935 lb/h. Note from capacity multiplying factor charts: A. Pump capacity if filling head is 24": 1.16 x 6,935 = 8045 lb/h B. Pump capacity using compressed air: 1.12 x 6,935 = 7767 lb/h (% back pressure is 38—75=50%) Motive Steam or Gas Supply Vent to atmosphere Condensate Return Pump Exhaust At least 12" Seal on overflow Vented Receiver (open system) Filling Head Filling Height Pressure Powered Pump TD 42L or 52L Trap when steam supply is used Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. 3:274 Condensate Return Line Recommended Installation The pump is fitted with vented receiver or an inlet reservoir. Details of the application will determine whether a vented receiver or an inlet reservoir will be needed to accomplish this. TI-5-030-US 4.13 The Pivotrol® Pump Patented Selection and Sizing Vented Receiver (Open System) Inlet Reservoir Piping (Closed System) To drain condensate from a single or multiple source an "open" system, a vented receiver should be installed in a horizontal plane above and ahead of the pump. Sufficient receiver volume is needed above the filling head level to accept the condensate reachng the receiver during the pump discharge stroke. More important, the receiver must be sized to allow sufficient area for complete flash steam separation from the condensate. The chart below shows proper vented receiver sizing (per criteria set forth in the A.S.H.R.A.E. Handbook) based on the amount of flash steam present. If the receiver is sized as shown below, there will be sufficient volume for condensate storage and sufficient area for flash steam separation. The receiver can be a length of large diameter pipe or a tank. To drain condensate from a single piece of equipment in a "closed" system, a reservoir should be installed in a horizontal plane above and ahead of the pump. Sufficient reservoir volume is needed above the filling head level to accept the condensate reaching the reservoir during the pump discharge stroke. The chart below shows minimum reservoir sizing, based on condensate load, needed to prevent equipment flooding during the pump dischare stroke. The reservoir can be a length of large diameter pipe or a tank. Pump size - up to 3"x 2" Pump size - up to 3"x 2" Vent Line Diameter 1-1/2" 2" 3" 4" 6" 6" 8" Pump Size – PTF4 Flash Steam up to – 1000 lb/h 2000 lb/h 3000 lb/h 4000 lb/h 5000 lb/h 6000 lb/h 7000 lb/h 8000 lb/h Pipe Size Diameter Length 16" 60" 20" 60" 24" 60" 26’’ 60" 28" 60" 30" 72" 32" 72" 36" 72" Vent Line Diameter 6" 8" 8" 10" 10" 12" 12" 14" Capacity Multiplying Factors for other Filling Heads Filling Head Inches mm Check valve and piping size, pump type 2" x 2" 3" x 2" PTF-HP PTF4 PTC/PTF PTC/PTF -3.0 -76 0.47 -1.0 -25 0.66 0.0 0 0.76 6.0 1520.90 12.0 3051.00 18.0 4571.08 24.0 6101.16 36.0 9141.38 48.0 1219 1.48 60.0 1524 N/A NA 0.40 0.43 0.69 1.00 1.02 1.04 1.17 1.25 N/A NA 0.23 NA 0.41 0.60.70 0.90.89 1.00.95 1.10.98 1.21.00 1.31.00 1.41.08 1.51.20 Liquid Reservoir Pipe Size lb/h 3" 4" 6" 8" 10" 500 or Less 2’ 1000 2’ 1500 3’ 2’ 2000 3.5’ 2’ 1’ 3000 3’ 2’ 4000 4’ 2’ 1’ 5000 6’ 3’ 2’ 6000 3’ 2’ 7000 3’ 2’ 8000 4’ 2’ 9000 4.5’ 3’ 2’ 10,000 5’ 3’ 2’ 11,000 5’ 3’ 2’ Condensate Recovery Flash Steam Pipe Size up to — Diameter Length 75 lb/h 4" 36" 150 lb/h 6" 36" 300 lb/h 8" 36" 600 lb/h 10" 36" 900 lb/h 12" 36" 1200 lb/h 16" 36" 2000 lb/h 20" 36" Pump Size – PTF4 Non-Electric Pumps Liquid Load Reservoir Pipe Size* lb/h 12"16"20"24" 10,000 5’ 3’ 2’ 20,000 10’ 7’ 4’ 30,000 9’ 6’ 4’ 40,000 12’ 7.5’ 6’ 50,000 9’ 6’ 60,000 9’ 6’ * When BP/MP is less than 50%, these reservoir lengths can be reduced by 1/2. Capacity Multiplying Factors for Motive Gas Supply (other than steam) 2" and 3" x 2" PTC / PTF % Back Pressure 10%20%30%40%50%60%70%80%90% VS. Motive Pressure (bp / MP) Capacity Multiplying 1.041.061.081.101.121.151.181.231.28 Factors PTF-HP 1.191.431.431.531.852.042.142.202.44 PTF4 1.191.431.431.531.852.042.142.202.44 Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. Capacity Multiplying Factors Capacity Multiplying Factors TI-5-030-US 4.13 3:275 The Pivotrol® Pump Patented Selection and Sizing Non-Electric Pumps Condensate Recovery Back Motive 3" x 2" 3" x 2" PTC/PTF 2" x 2" Motive Pressure Pressure PTF-HTF 3" x 3" PPF Top PTC/PTF Pressure psig psig 12" Filling Head lb/hr 12" Filling Head lb/hr 12" Filling Head lb/hr psig 200 180 200 160 200 140 200 120 200 100 200 80 200 60 200 50 200 40 200 30 200 20 200 10 180 160 180 140 180 120 180 100 180 80 180 60 180 50 180 40 180 30 180 20 180 10 160 140 160 120 160 100 160 80 160 60 160 50 160 40 160 30 160 20 160 10 140 120 140 100 140 80 140 60 140 50 140 40 140 30 140 20 140 10 120 100 120 80 120 60 120 50 120 40 120 30 120 20 120 10 100 80 100 60 100 50 100 40 100 30 100 20 100 10 80 60 80 50 80 40 80 30 80 20 80 10 60 50 60 40 60 30 60 20 60 10 50 40 50 30 50 20 50 10 40 30 40 20 40 10 30 20 30 15 30 10 20 15 20 10 15 10 - - 6375 7375 8250 9000 9685 10000 10310 10635 10950 11195 - 5425 6685 7760 8600 9450 9830 10230 10560 10895 11195 4250 5750 7040 8065 9105 9565 9990 10440 10870 11195 4625 6120 7420 8625 9190 9690 10245 10760 11195 4700 6475 7845 8530 9240 9865 10535 11065 4995 6620 7500 8370 9145 9900 10630 5010 6000 6935 7970 8870 10000 4250 5315 6360 7460 9190 4440 5625 6730 8690 4630 5850 7930 4810 5475 6820 4375 5210 4375 - 5250 7375 9440 11145 12565 14260 14875 15690 16310 17000 17640 3750 6335 8555 10375 11980 13625 14375 15150 15875 16665 17505 4860 7500 9375 11135 12940 13750 14565 15400 16270 17315 6085 8145 10065 12120 13000 13940 14875 15840 17045 6300 8625 10970 12100 13160 14250 15280 16655 6260 9255 10680 12040 13310 14460 16100 6485 8435 10185 11750 13250 15190 5000 7485 9625 11580 13750 5500 8125 10315 12755 5750 8700 11470 5810 8000 9690 5375 7450 6000 3518 4941 6325 7467 8419 9554 9966 10512 10928 11390 11819 2513 4244 5732 6951 8027 9129 9631 10151 10636 11166 11728 3256 5025 6281 7460 8670 9213 9759 10318 10901 11601 4077 5457 6744 8120 8710 9340 9966 10613 11420 4221 5779 7350 8107 8817 9548 10238 11159 4194 6201 7156 8067 8918 9688 10787 4345 5651 6824 7873 8878 10177 3350 5015 6449 7759 9213 3685 5444 6911 8546 3853 5829 7685 3893 5360 6492 3601 4925 4020 Back Pressure psig 300200 300185 300160 300140 300120 300100 30080 30060 30040 30020 30010 280200 280180 280160 280140 280120 280100 28080 28060 28040 28020 28010 250200 250180 250160 250140 250120 250100 25080 25060 25040 25020 25010 200180 200160 200140 200120 200100 20080 20060 20040 20020 20010 150120 150100 15080 15060 15040 15020 15010 125100 12580 12560 12540 12520 12510 10080 10060 10040 10020 10010 75 60 75 40 75 20 75 10 50 40 50 20 50 10 25 20 25 10 Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. 3:276 3" x 2" PTF-HP 12" Filling Head lb/hr 12550 13875 14565 15750 17125 19125 20315 22065 24375 27500 28750 11125 12435 13250 14435 16875 17875 19125 20850 23125 26125 27565 9190 10185 11000 12190 13935 15935 17065 19000 21200 24125 25700 6065 7190 8315 11935 12500 14065 15825 18125 20815 22315 7875 8875 10750 12625 14935 17375 19000 7065 9065 10875 13250 15500 16685 7245 9125 11435 13810 15375 7035 9435 12125 13565 5085 10185 11625 2750 9685 TI-5-030-US 4.13 The Pivotrol® Pump Patented Selection and Sizing 150 140 120 100 80 60 50 40 30 20 15 120 100 60 50 40 30 20 15 120 100 80 60 50 40 30 20 15 100 80 60 50 40 30 20 15 80 60 50 40 30 20 15 60 50 40 30 20 15 60 50 40 30 20 15 50 40 30 25 20 15 40 30 25 20 15 30 25 20 15 30 25 20 15 20 15 36” Fill Head (70” Fill Height) lb/hr 22120 22970 24870 27110 29860 33400 35640 38390 41930 46920 50460 23700 26020 32500 34810 37640 41300 46440 50090 22530 24920 27830 31590 33980 36890 40660 45960 49720 23410 26220 29850 32150 34960 38590 43710 47340 24610 28110 30320 33030 36530 41460 44950 24730 27100 30010 33750 39030 42780 21350 23880 26980 30970 36610 40600 21850 24830 28680 31120 34110 37960 22940 26840 29310 32330 36230 25310 27970 30910 34160 19480 22230 25600 29940 20440 25650 To size the PTF4 in a closed system: Establish available motive pressure. Establish static back pressure on Pump/Trap combination. Place established pressures in formula below: • Pump Motive Pressure (psig) – min. VAV delta P (psig) > Back Pressure (psig) • Capacity charts to be read as normal, i.e. at pump motive and back pressure. • If, Pump Motive Pressure (psig) – min. VAV delta P (psig) < Back Pressure (psig), then isolate or remove VAV and multiply capacity by 0.77 to find reduced capacity without VAV. Sizing Example: 1 A closed system has the following conditions: Motive steam available = 150 psig. Static Back Pressure = 45 psig. Open System. PTF4 Capacity charts show capacity at 150 psig motive with 45 psig back pressure. Closed System. The Vent Assist Valve on the PTF4 requires at least 75 psig differential pressure to operate in a closed system. Condensate Recovery 200 200 200 200 200 200 200 200 200 200 200 180 180 180 180 180 180 180 180 160 160 160 160 160 160 160 160 160 140 140 140 140 140 140 140 140 120 120 120 120 120 120 120 100 100 100 100 100 100 80 80 80 80 80 80 70 70 70 70 70 70 60 60 60 60 60 50 50 50 50 40 40 40 40 30 30 Back Pressure psig To size the PTF4 pump: Pump Motive Pressure – min. VAV delta P > Back Pressure. 150 psig – 75 psig > 45 psig As the motive pressure is 150 psig and the VAV requires a minimum 120 psig to operate (75 + 45 = 120), this combination is sized correctly. Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. Non-Electric Pumps Motive Pressure psig TI-5-030-US 4.13 3:277 The Pivotrol® Pump Capacity Charts Selection and Sizing Patented 2" x 2" Pivotrol® Pump 0 0 B a ck P ress ure ( 23ft IG B ) a ck 30 P P re S IG s s ure B ac 40 (4 6 PS kP IG ft) re s B ac su r 50 P e (6 kP S IG 9ft) res Ba su r ck 60 P e P (92 S IG re s ft) sur B ac e (1 kP 16 res ft) sur 80 P e( 1 39 S IG ft) Ba ck P re 100 ssu PS re IG ( 18 Ba 5ft ck ) P re 120 s s PS u re IG (23 Ba 1f ck t) P 140 r e PS s su IG re Ba (27 ck 7f Pr t es su re ( 32 3f t) 20 20 P S 30 40 50 60 70 80 Motive Pressure PSIG 10 90 100 110 120 130 140 150 160 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 ) 170 180 10500 11000 (14) (15) (16) (17) (18) (19) (20) (21) (22) 11500 10000 (13) 12000 9500 (11) (12) 9000 (10) 8500 (9) 8000 (8) 7500 (7) 6500 (6) 7000 (5) 6000 (4) 5000 (3) 5500 (2) 4500 3000 (1) 3500 2500 200 2000 200 1500 190 1000 190 500 Non-Electric Pumps 180 4000 Condensate Recovery 170 Motive Pressure PSIG 10 P S IG 10 lb/hr (23) (24) (GPM) 3" x 2" Pivotrol® Pump 0 0 10 10 40 50 60 Motive Pressure PSI G 70 80 90 100 110 120 130 140 150 160 20 30 40 50 60 70 80 90 100 110 120 130 G 30 10 P S IG B a ck P re ssur 20 P S IG e (23ft B a ck P ) re ssur 30 P S IG B e (46ft ack P re ) ssure (6 9ft) 40 P S IG B a ck P re ssure 50 P S IG (92ft) B a ck P re ss 60 P S IG u r e (116f B a ck P t) re ssu re (13 9ft) 80 P S IG B a ck P r e s su re (1 85ft) 100 P S IG B ac k Pr e ss ure 120 (23 PS 1 ft) IG B ack P re 140 P S ss u IG B re ack (27 P re 7f s 6 1 0P s u S IG re B ac (32 kP 3f res t) sur e (3 70 ft) Motive Pressure PSI 20 140 150 160 (26) (27) (28) (29) (30) 17500 (25) 17000 (24) 16500 (23) 15500 (22) 16000 (21) 15000 (20) 14500 (19) 14000 (18) 13500 (17) 13000 (16) 12500 10000 (15) 11500 9500 (14) 12000 9000 (13) 10500 8500 (11) (12) 11000 8000 200 7500 (9) (10) 190 7000 (8) 180 6500 (7) 170 6000 (6) 5500 4500 (5) 5000 4000 (4) 3500 200 2500 190 3000 180 2000 t) 170 (31) (32) (33) (33) (34) Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. 3:278 lb/hr (GPM) TI-5-030-US 4.13 The Pivotrol® Pump Patented Selection and Sizing PTF4 Capacity Chart 0 20 40 80 100 120 140 Condensate Recovery 160 180 Non-Electric Pumps 52,000 50,000 48,000 46,000 44,000 42,000 40,000 38,000 36,000 34,000 32,000 30,000 28,000 26,000 24,000 22,000 20,000 18,000 16,000 200 14,000 Motive Pressure PSIG 60 Capacity, lbs/hr Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. TI-5-030-US 4.13 3:279 The Pivotrol® Pump Selection and Sizing Patented 3" x 2" PTF-HP Pivotrol® Pump 0 20 20 P 40 PS IG B SIG B SIG 260 280 2 4,000 6.000 8,000 (2) (4) (8) (12) (16) 10,000 1,000 2,000 300 ft) (20) (24) 30,000 240 28,000 220 26,000 200 24,000 180 22,000 160 20,000 140 18,000 120 16,000 100 ack 14,000 80 Condensate Recovery B ac ack kP Pr re es Pre ss s 60 ss u ur ur e( PS re e( 46 IG (92 23 f Ba t 80 ft) ) ft) ck PS Pr IG e s Ba 10 su 0P ck re Pr SI (1 G e 39 ss 12 B ft) ac ur 0 e PS k P (1 re IG 85 s ft Ba sur e( ) ck 2 P 1 3 1 18 60 re 1ft 40 0P P ss ) PS SIG SI ur IG e Ba G B Ba (2 ck ac 77 ck Pr k P es r f t) P s 20 ure essu ress 0 ( PS 416 re (3 ure IG ft) 70 (32 3ft ft) (4 6 ) 60 12,000 MOTIVE PRESSURE (PSIG) 40 10 P (lb/hr) (28) (32) (36) (40) (44) (48) (52) (56) (60) (GPM) CAPACITY Non-Electric Pumps Pivotrol® Steam Consumption Chart • • PTF4 without insulation • insulation PTF - HP without PTC / PTF without insulation PTC / PTF with insulation PTF4 with insulation PTF - HP with insulation 14 • 13 Steam used per 1000lbs water 12 11 • 10 9 • 8 7 • 6 • 5 • 4 • 3 2 • • • • • 1 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Back Pressure (psig) TI-5-030-US 3:280 4.13 Patented Selection and Sizing TI-5-030-US Spirax Sarco, Inc., 1150 Northpoint Blvd, Blythewood, SC 29016 4.13 © Spirax Sarco, Inc. 2013 Non-Electric Pumps Condensate Recovery The Pivotrol® Pump Telephone: (803) 714-2000 FAX (803) 714-2222 3:281
© Copyright 2024