+7 ϼૈВྣமࡋໆෳБਢ SOLAR-02 㗗ᶨ⎘䱦ⶏ✳䘬⣒春㖍䄏⻟⹎姀抬☐ z 慷㷔嬨ῤ⎗ẍ⌛㗪栗䣢烊㚨⣂⎗ẍ⃚⬀ 3 䳬㖍䄏慷㷔デ ㅱ☐⍫㔠 z ⎗㍍ Reference Cell (⇑䓐⍾⼿ᾖ㬋⍫㔠䘬⣒春傥㧉 䳬䔞デㅱ☐Ἦ慷㷔烊╖㘞ㆾ⣂㘞䘮⎗) ㆾ㗗 Pyranometers (⇑䓐䅙暣➮(thermopile sensor)Ἦ䔞デㅱ ☐慷㷔) z ㍍ᶲ㹓⹎デㅱ☐Ṏ⎗慷㷔䑘⠫㹓⹎⍲⣒春傥㜧䘬㹓⹎烊 z 㨇⎘㛔幓⎗ẍ慷㷔⣒春傥㜧䘬奺⹎(栆Ụ㯜⸛₨䘬≇傥) z 妲嘇廠↢ṳ朊㚱 USB RF ℑ䧖炻⎗ẍ℞Ṿ HT ↢ ⑩䘬䚠斄₨☐䚜㍍忋≽忚埴姀抬ㆾ嬨⍾㔠㒂 ᷣ㨇ᶵ⏓デㅱ☐暨怠岤 PT300N 㹓⹎デㅱ☐ HT304N 㖍䄏⻟⹎デㅱ☐ PT300N ⎴㗪℟㚱ℑ䳬㹓⹎デㅱ☐ ⎗慷㷔 䑘㐔㹓⹎ẍ⍲ ⣒春傥㜧䘬㹓⹎ HT304N 㗗姕妰䓐Ἦ慷㷔⣒春㖍䄏⻟⹎䓐䘬デㅱ☐ z ╖㘞ㆾ⣂㘞⺷䘮⎗㓗㎜ z ⇑䓐ⶪⓖ⣒春傥㜧䚠⎴㛸岒 ㆸ䘬⍫䄏㧉䳬 (Reference cell)炻⃀慷⍾⼿ⶪⓖ⣒春傥㜧庫䁢㍍役䘬 㔠ῤ烊Ữ㭷ᾳデㅱ☐↢屐㗪悥㚫㍸ὃ℞䈡⿏⍫㔠烊ẍ ⛐惵⎰ SOLAR-02 慷㷔㖍䄏⻟⹎㗪⎗ẍ㍸ὃ庫䁢㸾䡢 䘬㖍䄏⻟⹎ῤ ! ԅׇӊོӉԢ१ϲѥ!SBEJPUFL!DPSQPSBUJPO! ⎘⊿烉ᶱ慵ⶪ慵㕘嶗Ḽ㭝 609 16 嘇 5 㦻ᷳ 7 TEL:02-22782269 FAX:02-22782059 㕘䪡烉㕘䪡䷋䪡⊿ⶪ⎘⃫ 26 嘇 4 㦻ᷳ 10 TEL:03-552-6779 FAX:03-552-6739 ⎘⋿烉TEL:06-204-3276 FAX:06-204-3096ġ ġ 㜙卆烉⺋㜙䚩㜙卆ⶪ⋿❶⋨⬷⚾嶗叔䥹.慹➇厗⹄3 㢇2 ╖⃫2602 ⭌ TEL: 0769-22365900ġ FAX: 0769-223633466 喯ⶆ烉㰇喯䚩喯ⶆⶪ㟸㴯⊿嶗 26-6 嘇Ⲙ⣏ 2F268 ⭌ TEL:0512-65236999 FAX:0512-65235999 Home page: www.radiotek.com.tw E-mail : [email protected] HT 62/$5 Ьᐒଛӝ +71 Ϸ 371 SOLAR-02 Rel. 1.00 of 24/03/10 Remote unit for connection to master PV instruments Pag 1 of 1 1. TECHNICAL SPECIFICATIONS Accuracy is defined to reference conditions: temperature 23°C, humidity <80%RH Irradiation Range [W/m2] 0 y 1400 Resolution [W/m2] 1 + INT (100 * 0.1/K) Accuracy r(1.0%rdg + INT(1000 * 0.1/K) K = sensitivity of the probe used to measure irradiation (expressed in mV/kW/m2 or in PV/W/m2) Probe sensitivity K<10 Kt10 Range [mV] 0.00 y 15.00 0.00 y 65.00 Resolution [mV] 0.01 0.02 Uncertainty r(1.0%rdg+0.1mV) Temperature (with PT300N probe) Range [°C] -20.0 y 99.9 Resolution [°C] 0.1 Accuracy r(1.0%rdg + 1°C) Resolution [°] 1 Accuracy r(1.0%rdg + 1°) Tilting angle Range [°] 1 y 90 2. GENERAL SPECIFICATIONS Display: LCD Custom, 4 dgt (2000 counts) + decimal comma and point Power supply Internal batteries: Battery life: AutopowerOFF: 4x1.5V alkaline type AAA LR03 approx 480 in continuous operation after 5 minutes of idleness (in independent mode) Input connectors USB port: PYRA/CELL inputs: USB 2.0 type Hypertac Internal memory Autonomy: approx 1.5 hours (@ PI master meter = 5s) Mechanical characteristics Dimensions: Weight (included batteries): 120(L)x 65(W) x 35(H)mm ; 5(L)x3(W)x1(H) “ 215g (8 ounces) Environmental conditions Operating temperature: Relative operating humidity: Storage temperature: Storage humidity: 0° y 40°C < 80%RH -10 y 60°C <80%RH This instrument complies with the requirements of Directive EMC 2004/108/EC HT ITALIA srl 宇宏企業股份有限公司 Via della Boaria 40 - 48018 Faenza (RA)- Italy Tel: +39-0546-621002 - Fax: +39-0546-621144 台北:三重區重新路五段609巷16號6樓之1 新竹:新竹縣竹北市台元26號4樓之10 email: [email protected] http://www.htitalia.com TEL:02-22782269 FAX:02-22782059 - web:TEL:03-552-6779 FAX:03-552-6739 http://www.fluke-tektronix.tw http://www.radiotek.com.tw HT304N Rel. 1.00 del 24/08/11 Reference cell for sun irradiation measurement Pag 1 of 1 WARNINGS ABOUT USE OF REFERENCE CELL HT304N x x x x x x x x x HT304N is a passive sensor and do not require any power supply Avoid exposing the instrument to mechanical shock paying additional attention to the glass Protect the glass against any contact with abrasive surfaces Do not apply any voltage to instrument’s outputs Install the sensor in position clear of obstructions that may introduce shading or reflections effects by distorting the sensor reading Always check the parallelism between the sensor and the photovoltaic module under consideration (error max r 2 °). The non-perfect parallelism between the sensor and the PV module surface could affect the outcome of the measure The usage of the stirrup is highly recommended. Fix the stirrup in a central position of the PV module edge. The stirrup is provide of a fixing screw compatible with holes placed on the back side of the PV module frame Once positioned the stirrup, insert the sensor into its holder with its connectors oriented downside (if possible) in order to avoid shadowing effects Expose the sensor to the test conditions (radiation temperature, inclination) at least 1 minute before performing the readings in order to avoid working with the sensor not yet in steady state 1. TECHNICAL SPECIFICATIONS Irradiation Range [W/m2] 50 y 1400 Accuracy (*) r3.0% of readings (*) Accuracy is grant under the following conditions: x Temperature: -20 y 50°C ; Incidence angle: 90° r 25° ; Air mass (AM): 1.5 2. GENERAL SPECIFICATIONS Available reference cells: MONO Crystalline and MULTI Crystalline Silicon Guidelines Safety: Technical literature: Calibration: Mechanical protection: Pollution degree: IEC/EN 61010-1 IEC/EN 61187 IEC/EN 60904-2 IP65 in compliance with IEC/EN 60529 2 Mechanical characteristics Dimensions (LxWxH): Weight: 120x85x40 mm 260g Environmental conditions Working temperature: Storage temperature: -20°C y 50°C -20°C y 60°C This instrument complies with the requirements of the European Low Voltage Directive 2006/95/CE (LVD) and EMC Directive 2004/108/CE HT ITALIA SRL 宇宏企業股份有限公司 Via della Boaria 40 - 48018 Faenza (RA)- Italy Tel: +39-0546-621002 - Fax: +39-0546-621144 台北:三重區重新路五段609巷16號6樓之1 新竹:新竹縣竹北市台元26號4樓之10 email: [email protected] http://www.ht-instruments.com TEL:02-22782269 FAX:02-22782059 - web:TEL:03-552-6779 FAX:03-552-6739 http://www.fluke-tektronix.tw http://www.radiotek.com.tw
© Copyright 2024