Friday, November 14, 2014 Switching Leads to Future Promotional Theme Slides for Huawei S5700-LIBAT, Industry's First Battery LAN Switch Rapid Growth of Huawei Switches in the Enterprise Network Market Global Top 3 Switch Suppliers Gartner's Challengers Quadrant Challengers Leaders Revenue Market Share, 4Q 2012 2.40% 3.20% 17.10% Cisco HP Challengers Quadrant Huawei 11.50% 65.80% Juniper Other Source: Dell'oro Niche Players 1 Visionaries Huawei Box Switch Series Layer 3 10G S6700-EI Layer 2 1000M S5700-HI S5710-HI S5701-X-LI S5700-LI/S5700-X-LI S5700S-LI S5700-LI-BAT S3700-SI Layer 3 100M S2700-SI Layer 2 100M SMB S5700-EI/ S5710-EI S5700-SI Layer 3 1000M S1700 2 S5700-LI-CSFP S3700-EI S2700-EI S3700-HI S2750-EI Network Power Supply Challenges Frequent Power Failures in India, Africa, and the Middle East Terminals Commonly Used Against Power Failures Power Failure Influence on Network Devices Internet Power failure Due to frequent power failures, PCs are hardly used, and user terminals with backup power supplies or batteries are commonly used, such as laptops, tablet PCs, and smart phones. Power failures for minutes to hours are frequent in areas including India, Africa, and the Middle East. 3 When network communication devices are powered off, network communication is interrupted, failing to support customers' network applications. Network Where Power Failures Are Frequent Challenges Facing a Network Due to a Mains Power Failure Core layer Aggregation layer UPS Equipment room Devices are centrally deployed and UPSs are deployed for power protection. Access layer Building Devices are widely deployed in limited space. No power protection capability is available upon a mains power failure. Terminals 4 Core and aggregation layers: UPSs are deployed as backup power supplies for switches and servers in equipment rooms to allow the devices to work upon a mains power failure. Access layer: A large number of access devices are widely deployed on each floor of buildings. High-quality UPSs as backup power supplies cost high and occupy much space, while low-cost UPSs or external lead-acid batteries have low reliability and security, occupy much space, and have a short service life. Huawei Solution to Frequent Power Failures at the Access Layer Industry's First Switch with Built-in Batteries Storage batteries Charger S5700-LI-BAT battery LAN switch + Battery slot supporting the built-in lithium battery UPS Hot-swappable 4 AH and 8 AH lithium batteries are available. 5 Huawei Solution to Frequent Power Failures at the Access Layer Huawei S5700-LI-BAT series battery LAN switches (S5700-LI-BAT for short) are the industry's first switch series to support built-in batteries. If the mains power fails, batteries are automatically used to provide power, ensuring uninterrupted services. After the mains power is recovered, the mains are used to provide power and charge the lithium batteries. In this manner, devices at the access layer are provided with power when the mains power fails at the access layer. S5700-LI-BAT Battery LAN Switch Provides Continuous Power for Enterprise Services Customer Benefits Remote access Internet Home entertainment WAN Enterprise office Branch access Intelligent management and easy O&M lower the TCO by 50%. Huawei S5700-LI-BAT battery LAN switch ensures network uninterrupted access upon power failures. 6 Industry's first internal battery design: The highly integrated battery slot saves space and facilitates battery installation. Intelligent power management, prolonging the standby time: Intelligent power management and energy-saving technologies are adopted to prolong the standby time to 11 hours. Visualized management on battery status and predictable battery service life: Battery status can be displayed and managed on a web page. The standby time alarm function allows you to replace a battery before the battery service life ends. You do not need to replace all batteries on the entire network. Built-in batteries save the cost by higher than 50% compared with the cost using external UPS. High battery reliability: Battery LAN switches support various battery protection technologies and the alarm function. Industry's First Built-in Battery Design Industry Solution Huawei Built-in Battery Solution High integration, without occupying additional space. Supports hot swap, simplifying the installation and replacement. 7 Uses external storage batteries or UPSs that occupy much space, require power cables, and have low reliability. Requires power cables, making the installation and replacement complex. Standby Time (Unit: Hour) Standby Time (Unit: Hour) Intelligent Power Management Prolongs Standby Time 6 5 4 AH Lithium Battery 5.6 4.1 4.1 3.1 2.4 2.1 2 1.2 1 0 12 10 S5700-28P-LI-BAT S5700-28P-LI-24S-BAT 11.2 8 AH Lithium Battery 9.7 8.3 8.2 8 6 Long Standby Time and Battery Service Life 4.8 4 3 Minimum power cost 6.2 4.8 4.2 4 2.3 2 0 S5700-28P-LI-BAT S5700-28P-LI-24S-BAT 8 30% ports Up, 30% traffic on each port, EEE enabled on electrical ports 70% ports Up, 70% traffic on each port, EEE enabled on electrical ports Full load 4 AH and 8 AH built-in lithium batteries are available. Advanced battery management is used to prolong the battery service life to longer than four years and the standby time to 11 hours. You can insert a lead-acid battery charging module to support the external lead-acid battery. Minimum power cost 30% ports Up, 30% traffic on each port, EEE enabled on electrical ports 70% ports Up, 70% traffic on each port, EEE enabled on electrical ports Full load Unique Visualized Battery Management Visualized Battery Management and Predictable Service Life Lifecycle Cost Comparison Visualized Battery Management 10 8 10 8 6 4 2 2 3.6 1 1.2 0 Battery Battery purchase cost maintenance cost UPS External storage battery Huawei built-in battery 9 Status of the battery and switch can be displayed on a web page, simplifying management. The parameters status, capacity, and type of the battery are displayed. Batteries on the entire network can be managed in a unified manner, and the battery service life is predictable. When the standby time of a battery is shorter than the threshold, an alarm is generated, allowing you to replace the battery before the battery service life ends. You do not need to replace all batteries on the entire network. Built-in batteries save the cost by higher than 50% compared with the UPS solution. High Battery Reliability Battery Protection and Alarm Multiple battery protection functions such as overtemperature protection are supported to protect batteries. When the ambient environment of a battery does not meet the requirement, proper measures are taken to protect the battery, ensuring secure running of the battery and preventing damages to the battery. Six alarms such as the internal battery fault alarm are supported so that battery faults are reported in a timely manner, simplifying battery O&M and replacement. 10 S5700-LI-BAT Battery LAN Switch Description (1) S5700-28P-LI-BAT S5700-28P-LI-4AH 1. 24 10/100/1000BASE-T Ethernet ports 2. 20 100/1000BASE-X Ethernet ports 3. 4 1000BASE-X Ethernet ports 4. 4 Combo 10/100/1000BASET+100/1000BASE-X ports 5. 1 console port (RJ45) S5700-28P-LI-24S-BAT S5700-28P-LI-24S-4AH S5700-28P-LI-BAT S5700-28P-LI-4AH 1. Ground screw 2. AC power socket 3. AC terminal preventing strip 4. Battery slot or power module slot S5700-28P-LI-24S-BAT S5700-28P-LI-24S-4AH 11 S5700-LI-BAT Battery LAN Switch Description (2) Specification S5700-28P-LI-BAT (S5700-28P-LI-4AH) S5700-28P-LI-24S-BAT (S5700-28P-LI-24S-4AH) Ports 24 10/100/1000Base-T Ethernet ports, 4 GE SFP ports 28 GE SFP ports, 4 GE Combo 10/100/1000Base-T Ethernet ports Forwarding performance 42 Mpps 42 Mpps MAC 16K Power supply Built-in single AC power supply Power supply redundancy AC or DC power module of 150 W Battery The battery slot supports the pluggable lithium battery (4 AH or 8 AH) or charge module for external lead-acid battery. The backup power module can be inserted into the battery slot. The charge module is connected to the lead-acid battery through the power cable and temperature sensor. Battery management Batteries are managed on a web page where the battery type, status, and standby time are displayed. Power protection Protection against overtemperature, input overvoltage, input overcurrent, output overcurrent, undervoltage, and short circuit. Battery alarm An alarm is generated when input overvoltage, input overcurrent, output overcurrent, undervoltage, or an internal battery fault occurs, or when the standby time threshold is reached. Surge protection 6 kV System Hibernation N/A iStack N/A Note: The lithium batteries are sold with the S5700-28P-LI-4AH or S5700-28P-LI-24S-4AH that has a built-in 4 AH lithium battery by default. 12 S5700-LI-BAT Battery Specifications Specification 4 AH Lithium Battery 8 AH Lithium Battery Hot swap Supported Typical Standby time1 S5700-28P-LI-BAT: 4.1 hours S5700-28P-LI-24S-BAT: 2.1 hours Service life2 Longer than four years Maximum output power 50 W (rated power: 40 W) Dimensions (W x D x H) 100 mm x 205 mm x 40 mm Weight 0.8 kg Operating temperature Charging ambient temperature: 0°C to 45°C; discharging ambient temperature: -5°C to +50°C Relative humidity 5% RH to 95% RH, noncondensing Storage temperature Maximum storage time -20°C to +60°C; recommended range: 20°C to 30°C Six months in the temperature of lower than 40°C. The battery must be charged after the maximum storage time. S5700-28P-LI-BAT: 8.2 hours S5700-28P-LI-24S-BAT: 4.2 hours 80 W (rated power: 45 W) Note: 1. The standby time provided here is a value in the typical scenario when 70% ports on the switch are Up, 10% bandwidth on each port is occupied, and EEE is enabled on electrical ports. Standby time of a BAT-4AHA lithium battery working at the minimum power: S5700-28P-LI-BAT: > 5.6 hours; S5700-28P-LI-24S-BAT: > 4.1 hours Standby time of a BAT-8AHA lithium battery working at the minimum power: S5700-28P-LI-BAT: > 11.2 hours; S5700-28P-LI-24S-BAT: > 8.3 hours The standby time is shortened as the battery is used. 2. The service life provided here is a value in the typical scenario when the ambient temperature ranges from 20°C to 30°C and the battery discharging exceeds 50% for no more than twice per day. 13 HUAWEI ENTERPRISE ICT SOLUTIONS A BETTER WAY Copyright©2012 Huawei Technologies Co., Ltd. All Rights Reserved. The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.
© Copyright 2024