LF-313LD-RS-HP Refrigeration system controller Panel Technical data Power supply110V/220V AC/50~60Hz Temperature range-50~+80 DisplaySeven segment LED Working temperature-15~+70 MountingSnap-in(Panel) Accuracy1 3 Fit-in size137*28*32mm (Panel) Resolution0.1 Fit-in size171*141*39mm3(Rear box) Maximum output ratingCompressor 30A/250V(Resistance load) Heater 30A/250V(Resistance load) FanLampDefog 8A/250V(Resistance load) System parameter table No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Symbol tS td Sd dt di dd dS FS CL rt tA Description Set compressor stop temperature Define differential temperature Compressor start time delay after stop Defrost typeELorHS Defrost interval time Defrost duration time Defrost stop temperature Fan start temperature condenser cleaning time interval Temperature up delay time Sensor calibration adjustment Range -50°C ~ +80.0°C +0.1°C ~ +15.0°C 0 ~ 15 Min. EL/HS 0 ~ 24 Hour 0 ~ 60 Min. 0.0°C ~ +80.0°C -50°C ~ +30.0°C 0~250 day 0~15 sec. -10°C ~ +10.0°C Default -20°C +4.0°C 2Min. EL 4 Hour 20 Min. +25.0°C 0.0°C 0 day 0 sec. 0.0°C Lock system parameter table No. Symbol Description Range Default y lock/n unlock Select system parameters to lock or unlock y 1. Lo The upper temperature limit 2. tH tS ~ +80.0°C +50.0°C The lower temperature limit 3. tL -50°C ~ tS -50°C High temperature alarm 4. AH tS+td~+80.0°C +50.0°C Temperature reachAHafterHtvalue alarm start working 0~180 Min. 90 Min. 5. Ht Low temperature alarm 6. AL -50°C~tS -30°C Temperature reachALafterLtvalue alarm start working 0~180 Min. 60 Min. 7. Lt ti Defrost interval time type ti(hour)/CP(quarter hour) 8. tC y stop/ n running Fan working type y 9. FL Fan stop time(option for FL=y) 0~60 Min. 3 Min. 10. OF Fan run time(option for FL=y) 0~60 sec. 15 sec. 11. On Note (1).After chooseyon the first lock system parameterLO; means you select to lock the system parametersdisplay will show system parametertSonlyand it can only be adjusted within the highest tH and lowesttLtemperature limitno other system parameters can be changedthereafter. On the contrary ifn is selectedthen all system parameters can be modified. (2).tCmeans defrost time count type .ti means hour’s unitCPmeans compressor running timeuse quarter hour unit. Self test function Error code E1H E1L E2H E2L Description Sensor shorted or temperature higher than +80.0°C Sensor opened or temperature lower than -50°C Evaporator sensor shorted or temperature higher than +80.0°C Evaporator sensor opened or temperature lower than -50° Error code AH AL CLn EHP Description High temperature alarm Low temperature alarm Condenser need to be clean High pressure Alarm Operation : A. System parameter setting 1.Press SETkey the display flashes pattern888for 3 times then shows the symbol of the first system parametertS this means the controller entering the parameter modifying phase can press orkey to scroll up/down the parameter that is going to be adjust.Press SETkeythe display shows set valuecan push orkey to increase or decrease the value by one unitpress theSETkey the controller goes to modify the next parameter. PressSETkeythe display shows888 then display cabinet-room temperature mean that you finish parameters setting. 1030095 REV:1 C,S:72D3H 102808 LF-313LD-RS-HP Refrigeration system controller B. Lock system parameter setting 1.PressSETkey for three secondsthe display begins flashing pattern888. While flashingpress bothandkeys together until display showsLo(which means into parameters lock). PressSETagain the modified value would be showed. At this timepressor to lock by choosingyor to unlock by choosingn. 2.After select system parameters to unlock pushSETkey the display shows pattern tH can press orkey to scroll-move to the next parameter. C. Other operations 1.After sent city power to controllerpushON/OFFkey to Power-onPonor Power-offPof. 2.After powerON the compressor is delaying for protecting. If you want to bypass the delay time and start immediately running the compressorthen you can pushkey until display showsFon. The controller then forces compressor to start up immediately. This special function is only effective on the power on stage. 3.Total operation hours (tot) The total compressor running time can be showed on display by showing three sets digits through push Press button andbutton simultaneously. For example if the total running time is 12345 hours the display will show first set “tot” (means total running time) then followed by the second digit set 012then the last digit set345. 4.If there is no key was pushed within 30 seconds the controller jump back normal temperature display **While “ CLn ” is flashing , pressto cease alarm.** **To reset the “CLn”error code, useon/offkey to trun Off power and turn on power again . The system will re-count the cleaning time. LED Indicators Function keys ON/ OFF Power on/off The controller power supply key Yellow Lamp on power supply Increase/ Decrease To increase or decrease one unit value Green Lamp flash compressor start up delay Lamp on compressor running Set Request for setting the parameter Red Lamp on system defrosting Manual defrost Push this key to do manual defrost Yellow Lamp on fan is running Door heater To on/off the door heater for clarify the showcase door Yellow Lamp on door heater is on Light on/off To on/off the indoor light appliance Yellow Lamp on indoor light appliance is on SET Sensor description 1.5M 1.5M 4.5cm 4.5cm 6 6 Isolation wire NTC sensor with BLACK VC/1.5M/4.5cm6φ metal head NTC sensor with RED PVC/1.5M/4.5cm6φ metal head Point 1 Lengthen your NTC sensor probe Please pay attention on below (1).Off the system power. (2).To avoid short circuit the connection points should be interleaved as shown right. NTC head Point 2 Controller Wiring diagram LF-3 1 3 LD -R S R ED 2 2 0 V B L A C K 1 1 0 V High P re s s u re N D S1 S2 G 3 2 1 R E D W H IT E Evaporator (R E D ) B L A C K R O O M (B L A C K ) S E N S O R 12 11 10 9 8 7 6 5 4 3 2 1 W H IT E DEFOG L A M P FA N DEFROS COMPT R E S S OR AC1 AC2 p o w e r lin e 1030095 REV:1 C,S:72D3H 102808
© Copyright 2024