Enhanced Gas Furnace Upflow/Horizontal

Enhanced Gas Furnace
Upflow/Horizontal
Variable Speed
Two Stage
Gas Furnace
G2D80CT-V
HEAT EXCHANGER
■
■
Efficient aluminized steel tapered S-curve design
Crimped no weld construction for longer life
■
■
■
■
Compact 40" height
Insulated to increase efficiency and reduce sound levels
Unitized construction for cabinet integrity
Prepainted baked polyester steel for
maximum durability
CABINET
BLOWER
■
■
■
■
Isolated and insulated compartment to reduce sound levels
Easily removable slide-out design
General Electric variable speed motor
Variable speed motors offer superior energy efficiency, low operating
sound and excellent air distribution
■ Dynamically balanced blower with belly band motor mount for smooth
and quiet operation
■ Blower ramp up and ramp down
BURNERS
■
■
Aluminized steel inshot burners for quiet ignition
Sealed burner enclosure for quiet operation
„
„
„
Honeywell two stage gas valve
Integrated two stage ignition and fan control board
Board features self diagnostics saving last five (5) fault codes in
nonvolatile memory for ease of service
Active and passive dehumidification in conjunction with cooling
Provides reverse polarity protection
Hot surface ignition using inconel shrouded, high density mini-ignitor
Control board provides terminals for electronic air cleaner, humidifier,
furnace twinning, and continuous low speed fan operations
Control circuit is fuse protected
40 VA transformer
Color coded control wiring
Single or two stage thermostat ready with selectable timings
CONTROLS
■
■
■
■
■
■
■
■
VENTING
■
2 speed draft motor with stainless steel shaft and
fan cooling for long life
■ Direct vent capable - one or two pipe
■ Outside combustion air ready
INSTALLATION
Limited lifetime heat exchanger
warranty for direct vent applications
20 year limited heat exchanger
warranty for all other applications
5 year limited on all parts
Extended warranty available
■
■
■
Left or right gas and electrical entry
Knock out base for bottom return
L models comply with California Energy Commission
Low NOx regulations
ACCESSORIES
■
■
Propane conversion kit
"Flush fit" coils
Model Number Guide
G
2D
80
C
T
100
V
20
C
L
-
1
A
G - Gas Furnace
Minor Revision Code
2D - Two Stage, Heat,
Direct Vent
Major Revision Code
Nominal AFUE
L - Low NOx
Cabinet Width
B = 17 1/2"
C = 21"
D = 24 1/2"
C - Series
T - Upflow/Horizontal
Nom. Btuh Input x 1000
Nom. Max. CFM x 100
V - Variable Speed
Physical and Electrical
First Stage
Second Stage
Min. Time
Flue
Volts/
Delay Nominal Trans. Weight
Size
Hz/Phase Breaker
F.L.A.
(V.A.) (lbs.)
(in.)
or Fuse
4
120/60/1
15
2.8
40
125
Input
(Btuh)
Output
(Btuh)
Input
(Btuh)
Output
(Btuh)
AFUE
Nom.
Cooling
Cap.
G2D80CT050V12B 35,000
28,000
50,000
40,000
80
1.5-3.0
G2D80CT075V14B 52,500
42,000
75,000
60,000
80
2.0-3.5
4
120/60/1
15
5.3
40
140
G2D80CT100V14B 70,000
56,000 100,000
80,000
80
2.0-3.5
5
120/60/1
15
5.3
40
155
G2D80CT100V20C 70,000
56,000 100,000
80,000
80
3.0-5.0
5
120/60/1
15
5.8
40
180
G2D80CT125V20C 87,500
70,000 125,000
100,000
80
3.0-5.0
5
120/60/1
15
5.8
40
190
G2D80CT150V20D 105,000 84,000 150,000
120,000
80
3.0-5.0
5
120/60/1
15
5.8
40
200
Model
Filter Requirement Data
Airflow
Descriptor
12
14
16
20
Disposable Filters
Cleanable Filters
Min. Area
(sq. in.)
576
672
768
960
Min. Area
(sq. in.)
288
336
384
480
1. The Airflow Descriptor is the two digits following the "D" in the model number; e.g. "20" is the Airflow Descriptor for G2080CT100V20C.
2. Areas and dimensions shown for permanent filters are based on filters rated at 600 feet per minute face velocity.
3. Typical filter sizes are shown, however, any combination of filters whose area equals or exceeds the minimum area shown is satisfactory.
Blower Performance Data
Temp.
Motor Blower
Rise
Size Size
o
F
Model
G2D80CT50V12B
1/3
10 x 8 30-60
G2D80CT075V14B
1/2
10 x 8 40-70
G2D80CT100V14B
1/2
10 x 8 50-80
G2D80CT100V20C
3/4 12 x 10 45-75
G2D80CT125V20C
3/4 12 x 10 45-75
G2D80CT150V20D
3/4 12 x 10 55-85
Blower Speed Tap
Cooling CFM @ .50 ext.
Cooling
Heating CFM @ .50 static
static pressure in. W.C.
AdjustLow Fire High Fire ment Setting "A" Setting "B" Setting "C" Setting "D"
---Norm.
1132
991
808
605
---(+)
1127
1123
918
689
(-)
1004
853
671
516
---A Tap Setting*
575
748
--------Norm.
1421
1210
1011
813
---(+)
1514
1387
1168
944
---(-)
1196
1009
865
662
A Tap Setting*
750
998
--------Norm.
1395
1192
1005
796
---(+)
1489
1372
1154
933
---(-)
1195
1013
854
650
C Tap Setting*
900
1197
--------Norm.
2020
1867
1671
1479
---(+)
2028
2021
1909
1661
---(-)
1763
1616
1412
1253
A Tap Setting*
682
1153
--------Norm.
1945
1783
1603
1407
---(+)
1943
1944
1822
1598
---(-)
1673
1529
1354
1209
B Tap Setting*
950
1606
--------Norm.
1954
1801
1617
1430
---(+)
1960
1965
1816
1621
---(-)
1700
1550
1373
1211
C,D Tap Setting* 850
1437
------
*Required tap to maintain recommended rise.
Accessories
Kit Number
ALPKT582-1
AFILT524-1
AMB20A-1
AFILT529-1
AFUSE576
Description
Propane Conversion Kit
Horizontal/Upflow Side Return Filter Kit
(16 x 25 filter)
Filter Kit
Bottom Return Kit
Control Board Fuse Kit
Used with
All Enhanced 80 Furnaces
All 80 Upflow/Horizontal Furnaces
All Upflow Capable Models
All 80 Upflow/Horizontal Furnaces
All 80 Furnaces Model
Dimensions (in.)
Model
A
B
C
D
E
F
G2D80CT050V12B 17 1/2 16 1/2 14
6 1/2
5
3
G2D80CT075V14B 17 1/2 16 1/2 14
6 1/2 4 3/8 3 1/8
G2D80CT100V14B 17 1/2 16 1/2 14
6 1/2 4 1/2 3 1/4
G2D80CT100V20C
21
20 16 1/2 8 1/4 6 1/4 3 5/16
G2D80CT125V20C
21
20 16 1/2 8 1/4 4 5/8 3 1/4
G2D80CT150V20D 24 1/2 23 1/2 21
10
4 7/8 3 1/3
Clearances (in.)
Upflow
Model
Top
G2D80CT050V12B
G2D80CT075V14B
G2D80CT100V14B
G2D80CT100V20C
G2D80CT125V20C
G2D80CT150V20D
Right Left
Front Back Vent
Side Side
1
0
21
43
0
62
1
0
0
43
0
62
1
0
0
43
0
62
1 0" if B1 vent is used
2 1" if B1 vent is used
3 2" if B1 vent is used
Horizontal
Model
G2D80CT050V12B
G2D80CT075V14B
G2D80CT100V14B
G2D80CT100V20C
G2D80CT125V20C
G2D80CT150V20D
Right Left
Front Back Vent
Side Side
Airflow
R to L
L to R
Top Bottom Top Bottom
1
1
43
0
6²
1
31
31
0
1
1
43
0
6²
1
21
21
0
1
1
43
0
6²
1
0
11
0
1
0" if B1 vent is used
2
1" if B1 vent is used
3
2" if B1 vent is used
421 Monroe Street • Bellevue, OH 44811
(419) 483-4840
www.airease.com
Form #JG2DD80CT-V-100 (12/05)
Printed in U.S.A.
©Armstrong Air Conditioning Inc. 2005
*JG2D80CT-V-100-12-05*