Relion ® 630 series Motor protection and control REM630 Flexibility for demanding utility and industrial power distribution systems Protection and control for asynchronous and synchronous motors REM630 is a comprehensive motor management relay for protection, control, measurement and supervision of medium-sized and large asynchronous and synchronous motors in the manufacturing and process industry. (SLD) with position indication for the circuit breaker, disconnectors and the earthing switch. Also measured values can be displayed. The SLDs can be flexibly adjusted to meet user requirements using PCM600. Application REM630 has been designed to be the main protection for both asynchronous and synchronous motors and their drives, offering full protection during motor start-ups and normal drive operation. The motor management relay is typically used with circuit breaker and contactor-controlled, medium-sized and large motors with varying load in drives such as pumps, fans, compressors, mills and crushers. There are two predefined configurations, intended to match the most typical motor protection and control requirements, of which one is for medium voltage asynchronous motor applications and the other for asynchronous and synchronous motor applications requiring differential protection. The pre-defined configurations can be used as such or easily tailored to application-specific requirements with freely selectable functions. The 630 series HMI is distinguished by fifteen three-color LEDs and five configurable push buttons, which can be used as control buttons for various tasks such as blocking, adjusting setting groups or triggering the disturbance recorder. The five push buttons can also be conveniently used as menu shortcuts. Another distinguishing feature is the detached HMI, as an option to the integrated HMI, which is highly beneficial from a wiring perspective due to the large number of IOs the 630 series relays are equipped with. REM630 can be used in either single or double-busbar applications with one or two breakers and numerous switching devices. It also supports a substantial number of both manually and motor-operated disconnectors and earthing switches. Consequently, REM630 can be used to control various types of switchgears. An optional RTD/mA module offers eight analog RTD or mA measuring inputs and four mA outputs. The RTD and mA inputs can be used for temperature measurement of motor bearings and stator windings, thus extending the functionality of the thermal overload protection and preventing premature aging of the motor windings. They can also be used for measuring the ambient air or coolant temperature. The four mA outputs can be used for transferring freely selectable measured or calculated analog values to devices provided with mA inputs. The pre-configurations can be tailored to meet the application requirements using the IEC 61850-compliant protection and control IED manager PCM600. Human-machine Interface (HMI) As a member of the Relion® product family, REM630 shares the same Human Machine Interface (HMI) look and feel as the other Relion protection and control relays and IEDs. The same look and feel includes the location of a push button with a certain function and the menu structure. The 630 series relays are equipped with a large graphical display which can show customizable single-line diagrams 2 Motor protection and control | REM630 Standardized communication REM630 fully supports the IEC 61850 standard for communication in substations. The motor management relay also supports the DNP3 (TCP/IP) and 60870-5103 communication protocols, and is able to use two communication protocols simultaneously. The supported communication protocols, including IEC 61850, offer seamless connectivity to various station automation and SCADA systems. The implementation of the IEC 61850 standard in REM630 covers both vertical and horizontal communication, including GOOSE messaging according to IEC 61850-8-1 with both binary and analog signals. Analog GOOSE messaging enables fast transfer of analog measured values over the station bus. This facilitating, for example, sharing of RTD input values such as surrounding temperature with other relays. GOOSE messaging is also an alternative to traditional hardwiring signaling for exchanging interlocking information between the relays. For time-critical applications, REM630 supports synchronization over Ethernet using SNTP or over a separate bus using IRIG-B. 630 series REM630 is a member of ABB’s Relion product family and part of its 630 protection and control series. The 630 series relays are characterized by functional scalability and flexible configurability, and have been designed to unleash the full potential of the IEC 61850 standard for communication and interoperability of substation automation devices. In addition to REM630, the 630 series includes the following relays: • REF630 feeder protection and control • RET630 Transformer protection and control • REG630 Generator protection and control 3U REM630 MOTOR PROTECTION AND CONTROL IED Preconfiguration A for asynchronous motor LOCAL HMI *) PROTECTION ALSO AVAILABLE - 5 × prog. push buttons on LHMI - Disturbance and fault recorders - IED self-supervision - Local/Remote push button on LHMI - Sequence event recorder - User management - WebHMI 1× 1× I→O 94 3I 3I< 37 AND 2× I2>> 46R I2>G/M 46G/46M Is2t n< 48,66,14,51LR 3Ith>M 49M 3I>>> 50P/51P Ist> 51LR 3I> 51P-1 1× 1× 3I>/Io>BF 51BF/51NBF Io> 51N-1 OR *) Fixed or detached LHMI is available. COMMUNICATION CONDITION MONITORING AND SUPERVISION 3I Io Io Io FUSEF 60 1× 1× CBCM CBCM MCS 3I MCS 3I OPTS OPTM Io>> 51N-2 Protocols: IEC 61850-8-1 IEC 60870-5-103 DNP3 E E 3× 1× 1× U1> 47O+ 1× 1× U1< 47U+ Object 1) 3I>> 51P-2 Io>→ 67N-1 3× P> 32R/32O 2× 3U> 59 Io>→ 67N-2 1 1 0 1 1 1 0 1 0 1 0 1 0 0 1 0 0 0 0 0 1 1 0 0 1 1 1 1 1 1 1 0 0 0 1 0 2× 3× X< 40 Io>>> 50N/51N Uo> 59G Io>R 64R 3× f> 81O 6× 2) MEASUREMENT Ctrl CB 2) 2 8 ES 3U< 27 0 0 1 0 0 0 U<> U<> DC 2× 1 1 1 1 1 1 Interfaces: Ethernet: TX (RJ45), FX (LC) Serial: Serial glass fiber (ST), Serial plastic fiber (snap-in connector) TCS TCM CONTROL AND INDICATION 1) 1× 1× U2> 47O- A PRECONFIGURATION Check availability of binary inputs/outputs from technical documentation Control and indication function for primary object - I, U, Io, Uo, P, Q, E, pf, f - Sequence current/voltage measurement - Limit value supervision - RTD/mA measurement (optional) Analog interface types A Current transformer 51) Voltage transformer 4 1) One of available current transformer inputs is sensitive (0.1 / 0.5 A) ESTART ESTART df/dt> 81R REMARKS 3× f< 81U 3dl>G/M 87G/87M 3dlHi>G/M 87GH/87MH 16× MAP MAP Optional function 2× No. of instances enabled by default Function(s) not enabled by default in preconfiguration, can be enabled afterwards 1× No. of instances not enabled by default in preconfiguration, can be enabled afterwards Io/Uo Calculated value REM630 functional overview of the pre-configuration A. REM630 | Motor protection and control 3 REM630 motor protection and control pre-configurations Pre-configurations Preconfiguration Description Pre-configuration A for asynchronous motor A Pre-configuration B for asynchronous motor including differential protection B Number of instances available n Supported functions with codes and symbols IEC 61850 IEC 60617 ANSI A B n Three-phase non-directional overcurrent, low stage PHLPTOC 3I> 51P-1 1 1 1 Three-phase non-directional overcurrent, high stage PHHPTOC 3I>> 51P-2 - - 1 Three-phase non-directional overcurrent, instantaneous stage PHIPTOC 3I>>> 50P/51P 1 1 1 Non-directional earth-fault, low stage EFLPTOC I0> 51N-1 1 1 1 Non-directional earth-fault, high stage EFHPTOC I0>> 51N-2 1 1 1 Non-directional earth-fault, instantaneous stage EFIPTOC I0>>> 50N/51N - - 1 Directional earth-fault, low stage DEFLPDEF I0> → 67N-1 - - 1 Directional earth-fault, high stage DEFHPDEF I0>> → 67N-2 - - 1 Rotor earth-fault MREFPTOC Io>R 64R - - 1 Phase reversal PREVPTOC I2>> 46R 1 1 1 Negative-sequence overcurrent protection for motors MNSPTOC I2>M 46M 2 2 2 Three-phase thermal overload for motors MPTTR 3Ith>M 49M 1 1 1 Loss of load supervision LOFLPTUC 3I< 37 1 1 1 Motor load jam JAMPTOC Ist> 51LR 1 1 1 Stabilized differential protection for motors MPDIF 3dI>M 87M - 1 1 MHZPDIF 3dIHi>G/M 87GH/87MH - - 1 Three-phase underexcitation UEXPDIS X< 40 - - 2 Emergency start ESMGAPC ESTART ESTART 1 1 1 Motor start-up supervision STTPMSU Is2t n< 48,66,14,51LR 1 1 1 Three-phase overvoltage PHPTOV 3U> 59 - - 2 Three-phase undervoltage PHPTUV 3U< 27 - - 2 Positive-sequence overvoltage PSPTOV U1> 47O+ 1 1 2 Positive-sequence undervoltage PSPTUV U1< 47U+ 1 1 2 Negative-sequence overvoltage NSPTOV U2> 47O- 1 1 2 Residual overvoltage ROVPTOV U0> 59G - - 3 Reverse power/directional overpower DOPPDPR P> 32O - - 3 Frequency gradient DAPFRC df/dt> 81R - - 6 Overfrequency DAPTOF f> 81O - - 3 Underfrequency DAPTUF f< 81U - - 3 Circuit breaker failure CCBRBRF 3I>/I0>BF 51BF/51NBF 1 1 2 Tripping logic TRPPTRC I→O 94 1 1 2 Multipurpose analog protection MAPGAPC MAP MAP - - 16 Functionality Protection High-impedance or flux-balance based differential protection for machines 4 Motor protection and control | REM630 Supported functions with codes and symbols IEC 61850 IEC 60617 ANSI A B Bay control QCCBAY CBAY CBAY 1 1 1 Interlocking interface SCILO CILO 3 2 2 10 Circuit breaker/disconnector control GNRLCSWI I ↔ O CB/DC I ↔ O CB/DC 2 2 10 Circuit breaker DAXCBR I ↔ O CB I ↔ O CB 1 1 2 Disconnector DAXSWI I ↔ O DC I ↔ O DC 1 1 8 Local remote switch interface LOCREM R/L R/L - - 1 Single point control (8 signals) SPC8GGIO - - - - 5 Double point indication DPGGIO - - - - 15 Single point indication SPGGIO - - - - 64 Generic measured value MVGGIO - - - - 15 Logic Rotating Switch for function selection and LHMI presentation SLGGIO - - - - 10 Selector mini switch VSGGIO - - - - 10 Pulse counter for energy metering PCGGIO - - - - 4 Event counter CNTGGIO - - - - 1 Runtime counter for machines and devices MDSOPT OPTS OPTM - - 1 Circuit breaker condition monitoring SSCBR CBCM CBCM 1 1 2 Fuse failure supervision SEQRFUF FUSEF 60 1 1 1 Functionality n Control Generic process I/O Supervision and monitoring Current circuit supervision CCRDIF MCS 3I MCS 3I 1 1 1 Trip circuit supervision TCSSCBR TCS TCM 3 3 3 Energy monitoring EPDMMTR E E 1 1 1 Station battery supervision SPVNZBAT U<> U<> - - 1 Measured value limit supervision MVEXP - - - - 40 Three-phase current CMMXU 3I 3I 1 1 1 Three-phase voltage, (phase-to-earth voltages) (RMS) VPHMMXU 3Upe 3Upe - - 1 Three phase voltage, (phase-to-phase voltages) (RMS) VPPMMXU 3Upp 3Upp 1 1 1 Residual current RESCMMXU I0 I0 - - 1 Residual voltage RESVMMXU U0 Vn - - 1 Sequence current CSMSQI I1, I2 I1, I2 1 1 1 Sequence voltage VSMSQI U1, U2 V1, V2 1 1 1 Power monitoring with P, Q, S, power factor, frequency PWRMMXU PQf PQf 1 1 1 Analog channels 1-10 (samples) A1RADR ACH1 ACH1 1 1 1 Analog channel 11-20 (samples) A2RADR ACH2 ACH2 - - 1 Analog channel 21-30 (calc val) A3RADR ACH3 ACH3 - - 1 Analog channel 31-40 (calc val) A4RADR ACH4 ACH4 - - 1 Binary channel 1-16 B1RBDR BCH1 BCH1 1 1 1 Binary channel 17-32 B2RBDR BCH2 BCH2 1 1 1 Binary channel 33-48 B3RBDR BCH3 BCH3 1 1 1 Binary channel 49-64 B4RBDR BCH4 BCH4 1 1 1 Binary receive GOOSEBINRCV - - - - 10 Double point receive GOOSEDPRCV - - - - 32 Interlock receive GOOSEINTLKRCV - - - - 59 Integer receive GOOSEINTRCV - - - - 32 Measured value receive GOOSEMVRCV - - - - 60 Single point receive GOOSESPRCV - - - - 64 Measurement Disturbance recorder function Station communication (GOOSE) REM630 | Motor protection and control 5 ABB Oy Medium Voltage Products, Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone: +358 10 22 11 Fax: +358 10 22 41094 www.abb.com/substationautomation 1MRS756825 E For more information see REM630 Product Guide or contact us: © Copyright 2014 ABB. All rights reserved. Contact us
© Copyright 2024