TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Integrated Control Strategy TICS - Mid Range System Mid Range System TICS - Integrated Control Strategy TICS Mid Range Install controls without the complicated wiring Application UFH Radiator Central Control DHW Scheduled Or 4.3” Touch Screen cc245 Bus Network Sensor Type Bus Network And /Or Digital (2 Ch) Bus Network 7” Touch Screen cc200 Star Network And /Or Bead (2 Ch) Bus Network Plate (1 Ch) Star Network Complete Integration The system can interface with underfloor heating, radiators and hot water to ensure ideal comfort condition at minimum running cost. TICS - Integrated Control Strategy TICS – Mid Range Central Control: The control’s design enables all elements of the underfloor heating, Radiators and hot water to be managed centrally via a simple to use Touch Screen Interface. Total Flexibility At the console select Zone Type Select any Sensor Type Underfloor Heating Digital (2 Ch) Bus Network Radiators Bead (2 Ch) Bus Network Hot Water Plate (1 Ch) Star Network Mix and match to suit your application System will automatically assign the zones numbering Energy Efficient: Time and temperature control for each zone, combined with auto optimisation capabilities, which automatically learns the thermal inertia of each zone, including hot water hysteresis. This system results in high comfort levels and impressive energy savings capabilities. Reliability All control devices are individually tested prior to despatch which dramatically reduces failure rates and consequently improves on-site product reliability. User Friendly Time, effort and expertise have been invested to develop an intuitive, easy-to-use, touch screen interface which enables the end user centrally control of the all elements of the system at the touch of a key. TICS - Integrated Control Strategy TICS – Reliability Reliability 100% Product Function Testing Reliability All control devices are individually tested prior to despatch which dramatically reduces failure rates and consequently improves on-site product reliability. Extensive Diagnostics Embedded diagnostic facilities quickly identify typical installation and service issues. Pump Exercising Routine Ensure pumps are kept operational during periods of inactivity. 12v Operation No Batteries - No Replacing, No Recurring Cost, No Leaking No RF issues - 100% reliability All products are CE approved Health & Safety Significantly reduces the amount of 220v cable installed thought out the building TICS - Integrated Control Strategy TICS – Simple To Operate Central Console Touch Screen Console Simple user friendly icons Room Sensors 3 Button Warmer Cooler Override User Friendly Time, effort and expertise have been invested to develop an intuitive, easy-touse, sensor and touch screen interface Zone Labelling Zone designations are clearly labelled. View Room Settings Enables the user to view and edit every zone setting. Stop Facility Ideal for rooms which are not in use. Lockout Disable zone sensor buttons. Control at your finger tips TICS - Integrated Control Strategy TICS – Energy Efficient Mid Range & Advance System – See Module Options 32 Zones individual Temperature & Scheduling Individual time & temperature control of each zone. Boost Heat Take advantage of low cost energy tariff periods. Hot Water Management Time & Temperature, Hysteresis & Legionella Boost functions Zone Settings Set back Tracking – ensure heat-up time are not over stretched Outstanding Energy efficient features TICS - Integrated Control Strategy TICS – Comfort Features Zone Temperature Independent temperature control per zone E.g. Bedrooms 20°C, Baby Bedroom 24°C. Programmable Timer Individual zone scheduling to homeowner personal settings. Hot Water Boost HW boost activates the DHW for 2 hours. Optimisation Optimisation is a mechanism that ensures zone temperatures are reached at the scheduled times, including an automatic learning mode. Frost Protection The system protects against frost even when a zone is not in use. TICS - Total Integrated Control Strategy TICS: Mid Range - Home Owner Central Control: All elements of the heating, & hot water managed Up to 32 zones All rooms can be managed individually to reduce running costs. Touch Screen 4.3” - CC245 Time & Temperature Control Temp (SP/SB/BH) / Timer 7 day inc 4 x SP per day Simple To operate Typical user operations require one or two keystrokes. Edit Zone Labeling Zone label edit capability Relay Board R10i8s2 4 Modes All Off / All On / Manual / Timed. Holiday Select dates of an upcoming Holiday. Sensor Lock Out Ability to disable the use of room sensor button. View Room Settings View & edit each room setting./ View all zones status Hot Water Boost Scheduling / Boost / Hysteresis /Legionella Purge Sensor Options Digital (2 Ch) (Bus) Bead (2 Ch) (Bus) Plate (1 Ch) (Star) Whole House Status View status of all zones at a glance. Optimization 4 Setting including an automatic learning mode. The control’s design enables all elements of the underfloor heating, radiators and hot water to be managed centrally via a simple to use Touch Screen Interface. TICS - Integrated Control Strategy TICS: Mid Range - Integration Console Central Control of all elements (UFH / Rad / DHW) Zoning Individual Time & Temperature Control via Discrete Plate Sensors or Digital Sensors Hot Water Time & Temperature Control via Cylinder Stat Mechanical Manage all Actuators /Valves /Pump/Boiler Demand. Schedule Schedule element such as Garden Sprinklers Simple Setup TICS - Integrated Control Strategy TICS: Time & Cycling Relays Timers Individually Assigned Time ON Delays (1-99 Min) Individually Assigned Time Off –Overrun (1-99 Min) Solves noise issues Pump Exercising Routine Assign Cycle Interval (Hrs) e.g. 336 (2 weeks) Assign Cycle Duration (1-30 Min) Solves noise issues TICS - Integrated Control Strategy TICS - Installation Cabling – 1st Fix 1st Fix Cabling (Sensors) All Low Voltage Plates - Star (2 wire) Digital - Bus (4 wire) Cabling Single cable bus network design reduces installation time and costs. Reduce electrical cost approx 50%-60% No Containment Duct or Conduits 12v – safer for the end user TICS - Integrated Control Strategy TICS - Installation Cabling – 2nd Fix TICS manages all interlocks !!! Traditional Controls TICS Controls Install controls without the complicated wiring 2nd Fix Cabling (Mechanical) Single Point wiring Manage all Zone Valves, Pump & Boiler Demand. Impressive M&E Savings System manages interlock !!! Time Delay & Pump Exercising Configurable Time On Delay, Overrun & Pump Exercising Simple No on site complex wiring No Phone Calls Eliminate electrical phone calls No Interlock Wiring TICS - Integrated Control Strategy TICS : Commissioning Mid Range Configurable (R10i8 Board) Tailored Tailor the system to suit project requirements Sensors: Digital (2Ch)/ Bead (2Ch)/ Plate (1Ch) Manage: UFH/ Rad/ DHW/ Scheduled (Lights, sprinklers etc) Control: All Pumps, Valve & Boiler Demands Effortless Commissioning Easy Drop-Down List Selection Pump Aufh Pump MF Pump Ht Pump DHW Pump Rad Boiler (All UFH zones) (Only UFH this MF) (UFH & Rad) (All DHW zone) (All Rad zones) (UFH/Rads/DHW) Controls built to suit a changing world TICS - Total Integrated Control Strategy TICS: Mid Range - Optional Modules Optional Modules Touch Screen 4.3” - CC245 M Remote Access Broadband Router with Wifi Required (Hardware & Software) M DHW Priority Automatically override heating zones M Basic Cooling (R8) Override Boiler & active a single whole house cooling device M Extend Drop Down List Extend Install Basic Installation / Commissioning Drop Down List M Input config - Modes System Mode Inputs-Trigger Seasons & Master Modes) M Alarms Via Inputs – Display -Front Screen System Options O Touch Screen 4.3” or 7” Options O Sensors Digital (2ch) (Bus )(Dual) /Bead (2ch) (Bus) (Dual) /Plate (1ch) (Star) O Screed Screed Max & Min override Select which Module and System Options suit your project requirements & 8/16/24/32 Zones TICS - Total Integrated Control Strategy Sample Layout 1 Equipment 4.3” Touch Screen Digital Sensors Bead Sensors DHW Probe (2ch) (Air & Screed Probe or Dual Zone) (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring Bus Wiring TICS - Total Integrated Control Strategy Sample Layout 2 Equipment 4.3” Touch Screen Plate Sensors DHW Probe (1ch) (Air ) Star Wiring TICS - Total Integrated Control Strategy Sample Layout 3 Equipment 4.3” Touch Screen Digital Sensors Bead Sensors Plate Sensor DHW Probe (2ch) (Air & Screed Probe or Dual Zone) (2ch) (Air & Screed Probe or Dual Zone) (1ch) (Air ) Bus Wiring Bus Wiring Star Wiring TICS - Total Integrated Control Strategy Sample Layout 5 Equipment 7” Touch Screen Digital Sensors Bead Sensors Plate Sensor DHW Probe (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring (1ch) (Air & Screed Probe or Dual Zone) Star Wiring TICS - Integrated Control Strategy TICS – 4.3” Touch Screen CC245 Whole House Status View status of all zones at a glance. Copy Schedule Helpful copy function between zones. Edit Zone Labeling Central Control: Zone label edit capability The control’s design enables all elements of the heating, and hot water managed centrally via a simple to use Touch Optimization Screen Interface. 4 Setting including an automatic learning mode. 32 zones All rooms can be managed individually to reduce running costs. Time change Summer /Winter automatic change over. Temperature Control Individual Set Point on each zone Set Point & Set Back 7 Day Programmable Timer Individual Timer for each Zone. Simple To operate Typical user operations require one or two keystrokes. Edit Zone Labeling Zone label edit capability 4 Modes All Off / All On / Manual / Timed. Holiday Select dates of an upcoming holidays. Legibility 4.3 inch Touch Screen 480*272 pixels Sensor Lock Out Ability to disable the use of room sensor button. View Room Settings Enables the user to view and edit each room setting. Hot Water Boost The HW key turns the Immersion on for 2 hours. Hysteresis – Stop Boiler Cycling Legionella – DHW 70 °C 1/2hr Scheduled Boost Property Value Excellent controls - property resale value increases. Environment Efficient Control Technology results in reduced gas emissions. that harm the environment. TICS - Integrated Control Strategy TICS – Sensors Types/ Finishes Digital – Slim Line 2 Channel 4 Wire Bus Network Colour: White Model: CCT764WHI Colour: Brushed Stainless Steel Model: CCT764BSS Colour: Mirrored Chrome Model: CCT764MC Bead Sensor 2 Channel 4 Wire Bus Network Colour: Legrand Special Model: CCB765 – Legrand Colour: Brushed Stainless Steel Model: CCB765BSS Colour: Mirrored Chrome Model: CCT765MC Colour: Legrand Special Model: CCB765 – Legrand Plate Sensor 1 Channel 2 Wire Star Network Colour: White (ABS) Model: CCP767WHI) Colour: Brushed Stainless Steel Model: CCB767BSS Colour: Mirrored Chrome Model: CCB767MC TICS - Integrated Control Strategy TICS – Digital Sensor CC764 Features Screen Screen: LCD Displays Actual & Set Point Temp Backlight : Blue Backlight with timeout. Zone Sensors SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use. BH - Boost heat Utilize low cost electricity. 7 day & 5/2 Programmable Timer * Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C. PI - Optimization* Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time. Stop Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back. Calibration Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2 Central Override at the Console * All sensor can be centrally overridden by the main console. Centralized Clock No need to enter date & time on each thermostat. Installation Simple to install, significantly reduce electrical costs. 12v Operation Low voltage for Heath & Safety issues. No Batteries—Eliminates dying & replacing old batteries No RF issues- 100% reliability. Set Back Tracking Ensure the Set Back always follows the Set Point. Network All sensors are network capable. Lockout* Dual Sensing channels Solves the problem of children interfering with the room All sensors are capable accurately measuring both the air temp or thermostats located public areas. and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures. Frost Protection Mode - Disable * Ensure all plumbing is protected against frost. Aux (Type 01) Configurable Aux Channel Floor surface Protection * External / Flow / Retune / Ref Temp Max floor temps setting, ensures floor surface are protected. Min Screed Temp: Floor Surface Warming * Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied. Accuracy Accuracy of 0.5° C Dual Zone (Type 02) Single Digital sensor with Probe, can manage 2 zones * Centrally set & control led at the console TICS - Integrated Control Strategy TICS – Bead Sensor CC765 Features Calibration Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2 Zone Sensors SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use. BH - Boost heat Utilize low cost electricity. 7 day & 5/2 Programmable Timer * Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C. Central Override at the Console * All sensor can be centrally overridden by the main console. Centralized Clock No need to enter date & time on each thermostat. Installation Simple to install, significantly reduce electrical costs. 12v Operation Low voltage for Heath & Safety issues. No Batteries—Eliminates dying & replacing old batteries No RF issues- 100% reliability. PI - Optimization* Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Set Back Tracking Auto: This setting will self-learn the thermal inertia of Ensure the Set Back always follows the Set Point. the room and adjust the start time from memory to deliver the required temperature at the scheduled time. Network All sensors are network capable. Stop Ideal for rooms which are not in use. Dual Sensing channels Ignores timer schedule, moves to Set Back. All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit Frost Protection Mode - Disable * for screed temperatures. Ensure all plumbing is protected against frost. Floor surface Protection * Max floor temps setting, ensures floor surface are protected. Aux (Type 01) Configurable Aux Channel External / Flow / Retune / Ref Temp Dual Zone (Type 02) Min Screed Temp: Floor Surface Warming * Ideal for wet rooms, where occupant wishes to step onto Single Digital sensor with Probe, can manage 2 zones a warm floor even if the air temp has been satisfied. Accuracy Accuracy of 0.5° C Model: CCP765WHI CCP765MC CCP765BSS Colour: MK White (ABS) Mirrored Chrome Brushed Stainless Steel * Centrally set & control led at the console TICS - Integrated Control Strategy TICS Plate Sensor CC767 Wiring 2 Wire – Star Network 12v Operation Low voltage for Heath & Safety issues. No Batteries—Eliminates replacing old batteries No RF issues- 100% reliability. Installation Simple to install, significantly reduce electrical costs. Accuracy Accuracy of 1° C Model: CCP767WHI CCP767MC CCP767BSS Colour: White (ABS) Mirrored Chrome Brushed Stainless Steel * Central control via the console * Central Override at the Console * All sensor can be centrally overridden by the main console. * Zone Sensors SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use. BH – Boost heat Utilize low cost electricity. * 7 day & 5/2 Programmable Timer * Independent Temperature control for each Zone E.g. Bed Rooms 20°C, Baby Bed Room 24°C. * PI - Optimization Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time. * Stop Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back. * Frost Protection Mode - Disable * Ensure all plumbing is protected against frost. * Set Back Tracking Ensure the Set Back always follows the Set Point. * TICS - Integrated Control Strategy TICS Wiring Centre I/O Model: R10/i8 OUTPUTS BUS NETWORK Outputs (R10) 8 x 230v Powered Outputs – Zones 1 x 230v Powered Outputs – Manifold Pump 1 x S/L Output –Boiler (Switch live output can be jumpered to serve as a powered output) Network Terminal Bus network Connection ABGV Network with Console & Digital Sensors Bus network Connection ABG Network between I/O boards Max Network Overall Cable length 1200meter Led indication Each relay has a LED indicating the output status at a glance Addressing Dip switch address Up to 8 boards can be connected in a system Terminals 3 Connector terminals per relay. (A single relay can activate up to 3 actuators) Configurable: Tailored to suit your project Fuse Rate Relay 1-5 Relay 6-8 & ufh pump Relay 6 Boiler 230v Input Supply SUMMARY (Qty 1) (Qty 1) (Qty 1) (Qty 1) 4Amp 4Amp 4Amp 1Amp Slow Blow INPUTS Inputs Temperature Input 1-8 2 wire Temperature Input Operate with temp probe OR mechanical cylinder stat Interface with Thimble or Plate Sensors Switch Input Qty 2 Use with Optional Modules e.g. Back Boiler SUPPLY Supply Single 220v spur required at I/O Module Fuse Rating : 1Amp Slow Blow Reduce Electrical Installation Error & Cost Centralised All connections in one location Reduce Wiring Single drop connect each device Powered Individually Powered Outputs Termination All connection via screw terminal Layout Clear & accessible layout Diagnostics View Comms Status
© Copyright 2024