TICS - Modular (Mid Range System Features)

TICS - Integrated Control Strategy
TICS - Total Integrated Control Strategy
Mid Range System
Underfloor
Heating &
Cooling
Control
Solutions
Energy efficient
Heating and cooling
TICS - Integrated Control Strategy
TICS - Mid Range System
Mid Range
System
TICS - Integrated Control Strategy
TICS Mid Range
Install controls without
the complicated wiring
Application
UFH
Radiator
Central
Control
DHW
Scheduled
Or
4.3” Touch Screen cc245
Bus Network
Sensor
Type
Bus Network
And
/Or
Digital (2 Ch)
Bus Network
7” Touch Screen cc200
Star Network
And
/Or
Bead (2 Ch)
Bus Network
Plate (1 Ch)
Star Network
Complete Integration
The system can interface with underfloor heating,
radiators and hot water to ensure ideal comfort
condition at minimum running cost.
TICS - Integrated Control Strategy
TICS – Mid Range
Central Control:
The control’s design enables all
elements of the underfloor heating,
Radiators and hot water to be
managed centrally via a simple to
use Touch Screen Interface.
Total Flexibility
At the console select
Zone Type
Select any Sensor Type
 Underfloor Heating
Digital (2 Ch) Bus Network
 Radiators
Bead (2 Ch) Bus Network
 Hot Water
Plate (1 Ch) Star Network
Mix and match to suit your application
System will automatically assign the zones numbering
Energy Efficient:
Time and temperature control for each zone, combined with auto
optimisation capabilities, which automatically learns the thermal inertia of
each zone, including hot water hysteresis. This system results in high
comfort levels and impressive energy savings capabilities.
Reliability
All control devices are individually tested prior to despatch which
dramatically reduces failure rates and consequently improves on-site
product reliability.
User Friendly
Time, effort and expertise have been invested to develop an intuitive,
easy-to-use, touch screen interface which enables the end user centrally
control of the all elements of the system at the touch of a key.
TICS - Integrated Control Strategy
TICS – Reliability
Reliability
100% Product
Function Testing
Reliability
All control devices are individually tested prior to despatch which dramatically
reduces failure rates and consequently improves on-site product reliability.
Extensive Diagnostics
Embedded diagnostic facilities quickly identify typical
installation and service issues.
Pump Exercising Routine
Ensure pumps are kept operational during periods of inactivity.
12v Operation
No Batteries - No Replacing, No Recurring Cost, No Leaking
No RF issues - 100% reliability
All products are
CE approved
Health & Safety
Significantly reduces the amount of 220v cable installed thought out the building
TICS - Integrated Control Strategy
TICS – Simple To Operate
Central Console
Touch Screen Console
Simple user friendly icons
Room Sensors
3 Button
Warmer
Cooler
Override
User Friendly
Time, effort and expertise have been invested to develop an intuitive, easy-touse, sensor and touch screen interface
Zone Labelling
Zone designations are clearly labelled.
View Room Settings
Enables the user to view and edit every zone setting.
Stop Facility
Ideal for rooms which are not in use.
Lockout
Disable zone sensor buttons.
Control at your
finger tips
TICS - Integrated Control Strategy
TICS – Energy Efficient
Mid Range & Advance System – See Module Options
32 Zones individual Temperature & Scheduling
Individual time & temperature control of each zone.
Boost Heat
Take advantage of low cost energy tariff periods.
Hot Water Management
Time & Temperature, Hysteresis & Legionella Boost functions
Zone Settings
Set back Tracking – ensure heat-up time are not over stretched
Outstanding
Energy efficient
features
TICS - Integrated Control Strategy
TICS – Comfort Features
Zone Temperature
Independent temperature control per zone
E.g. Bedrooms 20°C, Baby Bedroom 24°C.
Programmable Timer
Individual zone scheduling to homeowner
personal settings.
Hot Water Boost
HW boost activates the
DHW for 2 hours.
Optimisation
Optimisation is a mechanism that ensures zone temperatures are reached at the
scheduled times, including an automatic learning mode.
Frost Protection
The system protects against frost even when a zone is not in use.
TICS - Total Integrated Control Strategy
TICS: Mid Range - Home Owner
Central Control:
All elements of the heating, & hot water managed
Up to 32 zones
All rooms can be managed individually to reduce running
costs.
Touch Screen
4.3” - CC245
Time & Temperature Control
Temp (SP/SB/BH) / Timer 7 day inc 4 x SP per day
Simple To operate
Typical user operations require one or two keystrokes.
Edit Zone Labeling
Zone label edit capability
Relay Board
R10i8s2
4 Modes
All Off / All On / Manual / Timed.
Holiday
Select dates of an upcoming Holiday.
Sensor Lock Out
Ability to disable the use of room sensor button.
View Room Settings
View & edit each room setting./ View all zones status
Hot Water Boost
Scheduling / Boost / Hysteresis /Legionella Purge
Sensor Options
Digital (2 Ch) (Bus)
Bead (2 Ch) (Bus)
Plate (1 Ch) (Star)
Whole House Status
View status of all zones at a glance.
Optimization
4 Setting including an automatic learning mode.
The control’s design enables all elements of the underfloor heating,
radiators and hot water to be managed centrally via a simple to use
Touch Screen Interface.
TICS - Integrated Control Strategy
TICS: Mid Range - Integration
Console
Central Control of all elements (UFH / Rad / DHW)
Zoning
Individual Time & Temperature Control via
Discrete Plate Sensors or Digital Sensors
Hot Water
Time & Temperature Control via Cylinder Stat
Mechanical
Manage all Actuators /Valves /Pump/Boiler Demand.
Schedule
Schedule element such as Garden Sprinklers
Simple Setup
TICS - Integrated Control Strategy
TICS: Time & Cycling
Relays Timers
Individually Assigned Time ON Delays (1-99 Min)
Individually Assigned Time Off –Overrun (1-99 Min)
Solves noise issues
Pump Exercising Routine
Assign Cycle Interval (Hrs) e.g. 336 (2 weeks)
Assign Cycle Duration (1-30 Min)
Solves noise
issues
TICS - Integrated Control Strategy
TICS - Installation
Cabling – 1st Fix
1st Fix Cabling (Sensors)
All Low Voltage
Plates - Star (2 wire)
Digital - Bus (4 wire)
Cabling
Single cable bus network design reduces installation time
and costs. Reduce electrical cost approx 50%-60%
No Containment Duct or Conduits
12v – safer for the end user
TICS - Integrated Control Strategy
TICS - Installation
Cabling – 2nd Fix
TICS manages all interlocks !!!
Traditional Controls
TICS Controls
Install controls without the complicated wiring
2nd Fix Cabling (Mechanical)
Single Point wiring
Manage all Zone Valves, Pump & Boiler Demand.
Impressive M&E Savings
System manages interlock !!!
Time Delay & Pump Exercising
Configurable Time On Delay, Overrun & Pump Exercising
Simple
No on site complex wiring
No Phone Calls
Eliminate electrical phone calls
No Interlock
Wiring
TICS - Integrated Control Strategy
TICS : Commissioning
Mid Range Configurable (R10i8 Board)
Tailored
Tailor the system to suit project requirements
Sensors:
Digital (2Ch)/ Bead (2Ch)/ Plate (1Ch)
Manage:
UFH/ Rad/ DHW/ Scheduled (Lights, sprinklers
etc)
Control:
All Pumps, Valve & Boiler Demands
Effortless Commissioning
Easy Drop-Down List Selection
Pump Aufh
Pump MF
Pump Ht
Pump DHW
Pump Rad
Boiler
(All UFH zones)
(Only UFH this MF)
(UFH & Rad)
(All DHW zone)
(All Rad zones)
(UFH/Rads/DHW)
Controls built to
suit a changing
world
TICS - Total Integrated Control Strategy
TICS: Mid Range - Optional Modules
Optional Modules
Touch Screen
4.3” - CC245
M
Remote Access
Broadband Router with Wifi Required (Hardware & Software)
M
DHW Priority
Automatically override heating zones
M
Basic Cooling (R8)
Override Boiler & active a single whole house cooling device
M
Extend Drop Down List
Extend Install Basic Installation / Commissioning Drop Down List
M
Input config - Modes
System Mode Inputs-Trigger Seasons & Master Modes)
M
Alarms
Via Inputs – Display -Front Screen
System Options
O
Touch Screen
4.3” or 7” Options
O
Sensors
Digital (2ch) (Bus )(Dual) /Bead (2ch) (Bus) (Dual) /Plate (1ch) (Star)
O
Screed
Screed Max & Min override
Select which Module and System Options
suit your project requirements
&
8/16/24/32 Zones
TICS - Total Integrated Control Strategy
Sample Layout 1
Equipment
 4.3” Touch Screen
 Digital Sensors
 Bead Sensors
 DHW Probe
(2ch) (Air & Screed Probe or Dual Zone)
(2ch) (Air & Screed Probe or Dual Zone)
Bus Wiring
Bus Wiring
TICS - Total Integrated Control Strategy
Sample Layout 2
Equipment
 4.3” Touch Screen
 Plate Sensors
 DHW Probe
(1ch) (Air ) Star Wiring
TICS - Total Integrated Control Strategy
Sample Layout 3
Equipment
 4.3” Touch Screen
 Digital Sensors
 Bead Sensors
 Plate Sensor
 DHW Probe
(2ch) (Air & Screed Probe or Dual Zone)
(2ch) (Air & Screed Probe or Dual Zone)
(1ch) (Air )
Bus Wiring
Bus Wiring
Star Wiring
TICS - Total Integrated Control Strategy
Sample Layout 5
Equipment
 7” Touch Screen
 Digital Sensors
 Bead Sensors
 Plate Sensor
 DHW Probe
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
(2ch) (Air & Screed Probe or Dual Zone) Bus Wiring
(1ch) (Air & Screed Probe or Dual Zone) Star Wiring
TICS - Integrated Control Strategy
TICS – 4.3” Touch Screen
CC245
Whole House Status
View status of all zones at a glance.
Copy Schedule
Helpful copy function between zones.
Edit Zone Labeling
Central Control:
Zone label edit capability
The control’s design enables all elements of the heating,
and hot water managed centrally via a simple to use Touch
Optimization
Screen Interface.
4 Setting including an automatic learning mode.
32 zones
All rooms can be managed individually to reduce running
costs.
Time change
Summer /Winter automatic change over.
Temperature Control
Individual Set Point on each zone
Set Point & Set Back
7 Day Programmable Timer
Individual Timer for each Zone.
Simple To operate
Typical user operations require one or two keystrokes.
Edit Zone Labeling
Zone label edit capability
4 Modes
All Off / All On / Manual / Timed.
Holiday
Select dates of an upcoming holidays.
Legibility
4.3 inch Touch Screen
480*272 pixels
Sensor Lock Out
Ability to disable the use of room sensor button.
View Room Settings
Enables the user to view and edit each room setting.
Hot Water Boost
The HW key turns the Immersion on for 2 hours.
Hysteresis – Stop Boiler Cycling
Legionella – DHW 70 °C 1/2hr Scheduled Boost
Property Value
Excellent controls - property resale value increases.
Environment
Efficient Control Technology results in reduced gas
emissions. that harm the environment.
TICS - Integrated Control Strategy
TICS – Sensors Types/ Finishes
Digital – Slim Line
2 Channel
4 Wire
Bus Network
Colour: White
Model: CCT764WHI
Colour: Brushed Stainless Steel
Model: CCT764BSS
Colour: Mirrored Chrome
Model: CCT764MC
Bead Sensor
2 Channel
4 Wire
Bus Network
Colour: Legrand Special
Model: CCB765 – Legrand
Colour: Brushed Stainless Steel
Model: CCB765BSS
Colour: Mirrored Chrome
Model: CCT765MC
Colour: Legrand Special
Model: CCB765 – Legrand
Plate Sensor
1 Channel
2 Wire
Star Network
Colour: White (ABS)
Model: CCP767WHI)
Colour: Brushed Stainless Steel
Model: CCB767BSS
Colour: Mirrored Chrome
Model: CCB767MC
TICS - Integrated Control Strategy
TICS – Digital Sensor
CC764 Features
Screen
Screen: LCD Displays Actual & Set Point Temp
Backlight : Blue Backlight with timeout.
Zone Sensors
SP - Set Point
Ambient Room Temp.
SB - Set Back
Room not in Use.
BH - Boost heat Utilize low cost electricity.
7 day & 5/2 Programmable Timer *
Independent Temperature control for each Zone
E.g. Bed Rooms 20°C, Baby Bed Room 24°C.
PI - Optimization*
Optimization is a mechanism of ensuring zone
temperatures are achieved according to the programmed
schedule.
Auto: This setting will self-learn the thermal inertia of
the room and adjust the start time from memory to
deliver the required temperature at the scheduled time.
Stop
Ideal for rooms which are not in use.
Ignores timer schedule, moves to Set Back.
Calibration
Calibration and address functions (Via Console)
Calibration Ch 1 & Ch 2
Central Override at the Console *
All sensor can be centrally overridden by the main console.
Centralized Clock
No need to enter date & time on each thermostat.
Installation
Simple to install, significantly reduce electrical costs.
12v Operation
Low voltage for Heath & Safety issues.
No Batteries—Eliminates dying & replacing old batteries
No RF issues- 100% reliability.
Set Back Tracking
Ensure the Set Back always follows the Set Point.
Network
All sensors are network capable.
Lockout*
Dual Sensing channels
Solves the problem of children interfering with the room
All sensors are capable accurately measuring both the air
temp or thermostats located public areas.
and an auxiliary probe. Ideal to set a maximum safety limit
for screed temperatures.
Frost Protection Mode - Disable *
Ensure all plumbing is protected against frost.
Aux (Type 01)
Configurable Aux Channel
Floor surface Protection *
External / Flow / Retune / Ref Temp
Max floor temps setting, ensures floor surface are
protected.
Min Screed Temp: Floor Surface Warming *
Ideal for wet rooms, where occupant wishes to step onto
a warm floor even if the air temp has been satisfied.
Accuracy
Accuracy of 0.5° C
Dual Zone (Type 02)
Single Digital sensor with Probe, can manage 2 zones
* Centrally set & control led at the console
TICS - Integrated Control Strategy
TICS – Bead Sensor
CC765 Features
Calibration
Calibration and address functions (Via Console)
Calibration Ch 1 & Ch 2
Zone Sensors
SP - Set Point
Ambient Room Temp.
SB - Set Back
Room not in Use.
BH - Boost heat Utilize low cost electricity.
7 day & 5/2 Programmable Timer *
Independent Temperature control for each Zone
E.g. Bed Rooms 20°C, Baby Bed Room 24°C.
Central Override at the Console *
All sensor can be centrally overridden by the main console.
Centralized Clock
No need to enter date & time on each thermostat.
Installation
Simple to install, significantly reduce electrical costs.
12v Operation
Low voltage for Heath & Safety issues.
No Batteries—Eliminates dying & replacing old batteries
No RF issues- 100% reliability.
PI - Optimization*
Optimization is a mechanism of ensuring zone
temperatures are achieved according to the programmed
schedule.
Set Back Tracking
Auto: This setting will self-learn the thermal inertia of
Ensure the Set Back always follows the Set Point.
the room and adjust the start time from memory to
deliver the required temperature at the scheduled time.
Network
All sensors are network capable.
Stop
Ideal for rooms which are not in use.
Dual Sensing channels
Ignores timer schedule, moves to Set Back.
All sensors are capable accurately measuring both the air
and an auxiliary probe. Ideal to set a maximum safety limit
Frost Protection Mode - Disable *
for screed temperatures.
Ensure all plumbing is protected against frost.
Floor surface Protection *
Max floor temps setting, ensures floor surface are
protected.
Aux (Type 01)
Configurable Aux Channel
External / Flow / Retune / Ref Temp
Dual Zone (Type 02)
Min Screed Temp: Floor Surface Warming *
Ideal for wet rooms, where occupant wishes to step onto Single Digital sensor with Probe, can manage 2 zones
a warm floor even if the air temp has been satisfied.
Accuracy
Accuracy of 0.5° C
Model:
CCP765WHI
CCP765MC
CCP765BSS
Colour:
MK White (ABS)
Mirrored Chrome
Brushed Stainless Steel
* Centrally set & control led at the console
TICS - Integrated Control Strategy
TICS Plate Sensor
CC767
Wiring
2 Wire – Star Network
12v Operation
Low voltage for Heath & Safety issues.
No Batteries—Eliminates replacing old batteries
No RF issues- 100% reliability.
Installation
Simple to install, significantly reduce electrical costs.
Accuracy
Accuracy of 1° C
Model:
CCP767WHI
CCP767MC
CCP767BSS
Colour:
White (ABS)
Mirrored Chrome
Brushed Stainless Steel
* Central control via the console
* Central Override at the Console *
All sensor can be centrally overridden by the main console.
* Zone Sensors
SP - Set Point
Ambient Room Temp.
SB - Set Back
Room not in Use.
BH – Boost heat Utilize low cost electricity.
* 7 day & 5/2 Programmable Timer *
Independent Temperature control for each Zone
E.g. Bed Rooms 20°C, Baby Bed Room 24°C.
* PI - Optimization
Optimization is a mechanism of ensuring zone temperatures
are achieved according to the programmed schedule.
Auto: This setting will self-learn the thermal inertia of the
room and adjust the start time from memory to deliver the
required temperature at the scheduled time.
* Stop
Ideal for rooms which are not in use.
Ignores timer schedule, moves to Set Back.
* Frost Protection Mode - Disable *
Ensure all plumbing is protected against frost.
* Set Back Tracking
Ensure the Set Back always follows the Set Point.
*
TICS - Integrated Control Strategy
TICS Wiring Centre I/O
Model:
R10/i8
OUTPUTS
BUS NETWORK
Outputs (R10)
8 x 230v Powered Outputs – Zones
1 x 230v Powered Outputs – Manifold Pump
1 x S/L Output –Boiler
(Switch live output can be jumpered to serve as a
powered output)
Network Terminal
 Bus network Connection ABGV
Network with Console & Digital Sensors
 Bus network Connection ABG
Network between I/O boards
 Max Network Overall Cable length 1200meter
Led indication
Each relay has a LED indicating the output status at a
glance
Addressing
Dip switch address
Up to 8 boards can be connected in a system
Terminals
3 Connector terminals per relay.
(A single relay can activate up to 3 actuators)
 Configurable:
Tailored to suit your project
Fuse Rate
Relay 1-5
Relay 6-8 & ufh pump
Relay 6 Boiler
230v Input Supply
SUMMARY
(Qty 1)
(Qty 1)
(Qty 1)
(Qty 1)
4Amp
4Amp
4Amp
1Amp Slow Blow
INPUTS
Inputs Temperature
Input 1-8
2 wire Temperature Input
Operate with temp probe OR mechanical cylinder stat
Interface with Thimble or Plate Sensors
 Switch Input
Qty 2
Use with Optional Modules e.g. Back Boiler
SUPPLY
Supply
Single 220v spur required at I/O Module
Fuse Rating : 1Amp Slow Blow
Reduce Electrical Installation Error & Cost
Centralised
All connections in one location
Reduce Wiring Single drop connect each device
Powered
Individually Powered Outputs
Termination
All connection via screw terminal
Layout
Clear & accessible layout
Diagnostics
View Comms Status