Thermal Inlet Ducts for Cisco Nexus^ 9396 and 93128 Switches for Net-Access™ S-Type Cabinets D ATA S H E E T Specifications The inlet duct shall be designed using CFD modeling and actual thermal lab verification, and shall be compatible with Cisco Nexus^ 9396 and Nexus^ 93128. The inlet duct shall optimize thermal performance by directing air from the cold aisle to the switch inlet preventing hot air recirculation. The use of passive inlet duct shall lower the average switch inlet temperature by 12oF to 22oF; resulting in reduced energy costs. The modular duct shall be capable of being installed in retro-fit applications and allow access to fan and power supply modules without disrupting existing in-cabinet equipment and cabling. Technical Information Inlet Duct for Top-of-Rack Switch Applications Dimensions: Nexus^ 9396PX - DIFBA2002S00S Nexus^ 9396TX - DIFBA2002S00S Nexus^ 93128TX - DIFBA3003S00S DIFBA2002S00S (2 RU): 29"-30"D (adjustable) x 3.50"H x 18.3"W (736.6 - 762mm D x 88.9mm H x 465mm W) DIFBA3003S00S (3 RU): 29"-30"D (adjustable) x 5.25"H x 18.3"W (736.6 - 762mm D x 133.35mm H x 465mm W) Key Features and Benefits Direct cool air to the switch: Increases energy efficiency in ToR applications and allows high density server applications Passive inlet duct: No additional moving parts or power required Day one or two installation: Eliminates the requirement to replace or disturb existing cabinets, equipment and infrastructure for lower capital expenditures and minimized risk Compatible with Panduit Server (S-Type) Cabinets: Allows maximum thermal efficiency Allows for installation in cabinets with mounting depths from 24 – 30" (610 – 762mm): Allows greater network flexibility and reliability Allows access to power supplies and fan blades: Allows ease of maintenance Bracket supports switch during installation: Allows single person ease of switch installation Applications Top of Rack (ToR) switches, such as the Cisco Nexus^ 9000 series, are designed to meet the server-access networking requirements of the virtualized data center. When deployed within server cabinets, the modular duct provides a cool air path to the air intakes of the switch. By providing a path for cool air to the switch, data center temperature set points can be raised – resulting in higher energy efficiencies and lower operating costs. ^Cisco and Cisco Nexus are registered trademarks and Cisco ACI is a trademark of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario [email protected] Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK [email protected] Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore [email protected] Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan [email protected] Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico [email protected] Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia [email protected] Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800.777.3300 ©2015 Panduit Corp. ALL RIGHTS RESERVED. RKDS09--WW-ENG 1/2015
© Copyright 2024