(F:\\\271\346\270\361\312\351\\00 LED driver\\LG Series\\LGU-40C

Constant current LED Drivers
For outdoor use
LGU-40C Series, 40 Watt
FEATURES:
Constant current output
Universal AC input: 90-305VAC
Active power factor correction
Short circuit, over voltage, over temperature protections
Designed to worldwide safety standards for lighting
Cooling by free air convection
5 year warranty
Model
Nominal
Input voltage
(Vac)
Output current
(mA)
Output voltage
(Vdc)
Output power
(W)
Min.
Max.
LGU40-C350
350
69
114
39.9
LGU40-C450
450
54
89
40
LGU40-C700
700
34
57
39.9
1050
23
38
39.9
LGU40-C1280
1280
19
31
39.7
LGU40-C1400
1400
17
29
40.6
LGU40-C1660
1660
14
24
40
LGU40-C1050
100-277
Note: 1. Add suffix for dimming option, “D” (0~10V), “P” (PWM), “T” (Timer);
2. Add suffix for package option, blank(default), “W” or “L”. See mechanical specifications.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
90
--
305
Vac
Input frequency
Fline
--
47
--
63
Hz
Input current
Iin
Full load, Vin = 230Vac
--
0.21
--
A
Inrush current
Iinrush
Cold start, Vin = 230Vac
--
--
35
A
Power factor
PF
70%~100% load, Vin = 230Vac
--
0.96
--
PF
η
Full voltage, full load
--
90
--
%
Efficiency
www.pairuigroup.com
Page: 1 / 6
Date: 01/20/2015
*Subject to change without prior notice.
Constant current LED Drivers
For outdoor use
LGU-40C Series, 40 Watt
ELECTRICAL
Output
Parameters
Output current accuracy
No load out voltage
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
--
--
--
5
--
%
LGU40-C350
--
--
130
V
LGU40-C450
--
--
103
V
LGU40-C700
--
--
67
V
LGU40-C1050
--
--
44
V
LGU40-C1280
--
--
36
V
LGU40-C1400
--
--
34
V
LGU40-C1660
--
--
29
V
VNO-Load
Line regulation
Iout-line
Vin from 90Vac to 305Vac
--
--
1
%
Load regulation
Iout-load
Vout from min. to max.
--
--
3
%
Iover-shoot
Turning power on
--
--
10
%
Ton_delay
Cold start, power on
--
--
2
S
--
--
--
20
--
%
Output Current
overshoot
Turn-on delay time
Ripple
Protection
Over voltage
115~150% rated output voltage. In latch mode, the power supply shall return to normal
operation only after the power is turned on again.
Short circuit
In hiccup mode, it will recover automatically after fault condition is removed.
Over temperature
Typ. 110
℃
Environment
Storage
Ambient operating
temperature
Maximum case
temperature
Operating relative
humidity
MTBF
www.pairuigroup.com
Tstorage
Humidity: 5% RH to 95% RH
-40
--
+85
℃
Ta
Startup at rated voltage
-40
--
+70
℃
Tc
Hot-spot on case
--
--
+80
℃
Ha
Non condensing
10
--
95
%
--
400
--
kHrs
TMTBF
Full load, 220Vac input,
℃
25
ambient temperature
Page: 2 / 6
Date: 01/20/2015
*Subject to change without prior notice.
Constant current LED Drivers
For outdoor use
LGU-40C Series, 40 Watt
ELECTRICAL
Environment
Dimension(LxWxH)
L: 193x43.5x34.5mm/W: 127x67.5x36.5mm
Weight
455g
Safety / EMC
Safety standards
EMC
UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1, EN61347-2-13
EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11,
EN61547
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 277Vac.
℃
and
MECHANICAL
PACKAGE TYPE “L”
Unit: mm
www.pairuigroup.com
Page: 3 / 6
Date: 01/20/2015
*Subject to change without prior notice.
Constant current LED Drivers
For outdoor use
LGU-40C Series, 40 Watt
MECHANICAL
PACKAGE TYPE “W”
Unit: mm
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 4 / 6
Date: 01/20/2015
*Subject to change without prior notice.
Constant current LED Drivers
For outdoor use
LGU-40C Series, 40 Watt
DIMMING FUNCTION
0~10V Dimming
External Resistor Dimming
ITEM
Conditions
Value
Maximum Voltage
Normally 10~11V
0~12V
0-10V Input Current
--
0~10mA
10V Output Voltage
Normally 11V
10~12V
10V Output Current
--
10mA Max.
Note: 1. To make the driver operate properly, the load voltage must be controlled above the minimum voltage
which
close to 50% of the maximum output voltage is from any given mode.
2. The dimming signal can be less than 1V. As it is for 0-1V ,the output current can maintain 10% of the rated output
current, but the connected LEDs may flicker. It's strongly recommended that keep dimming voltage bigger than 1V.
3. It is not allowed to connect the GND of dimming to the output, or the LED driver can not work as normal.
www.pairuigroup.com
Page: 5 / 6
Date: 01/20/2015
*Subject to change without prior notice.
Constant current LED Drivers
For outdoor use
LGU-40C Series, 40 Watt
DIMMING FUNCTION
PWM Dimming
ITEM
Conditions
Value
Input Voltage
--
1-10V
Input Current
--
10mA
PWM Frequency
--
0.5-3KHz
PWM Pulse Width
--
0~100%
Timer Dimming
Note: Above table for Timer dimming is just for reference, it can be adjusted according to the customer's requirements.
www.pairuigroup.com
Page: 6 / 6
Date: 01/20/2015
*Subject to change without prior notice.