HE A range guide

HE A combi, system
and heat only boilers
Range guide
Introduction
A brand you can trust 2
Baxi make it easy
3
Baxi Platinum
Combi HE A A brand you
can trust
Baxi make
it easy
Features and benefits 6-7
What’s inside the boiler? 8
Flues 9
We are so confident in the reliability of our boilers that we provide
industry-leading warranties, providing peace of mind for you and
your customers. And our warranty terms and conditions have been
approved by the Plain English Campaign so they are easy to understand.
1935
14
Flues 15
page
16
Technical specifications 18-19
What’s inside the boiler? 20
Flues 21
Baxi Solo
Heat Only HE A
Features and benefits 1955
Philip Baxendale, Richard’s great-grandson,
becomes General Manager as Baxi
becomes a household name
1966
Baxi develops a warm-air central
heating technology fuelled by gas
What’s inside the boiler? Features and benefits Warranty
An underfloor draught system for
solid fuel heating is launched – the first
product bearing the Baxi name
1963
12-13
Accessories17
1866
Iron moulder Richard Baxendale
opens the doors of his new company
10
Technical specifications Baxi Megaflo
System HE A
Every Baxi boiler has to pass a full function test using gas, water and
electricity, before it leaves the production line.
A brief history of Baxi
page
Accessories11
Reliability
*According to independent research.
4
Technical specifications Baxi Duo-tec
Combi HE A
We are committed to making your experience with Baxi as easy
as possible..
We continue to invest in the business to provide reliable, energy efficient heating and hot water,
backed by industry-leading customer support, nationwide availability of parts and training.
page
Accessories5
Features and benefits Baxi has been manufacturing in the UK for nearly 150 years. It has a heritage of providing cutting
edge heating products for homes and is the best known boiler manufacturer amongst homeowners*.
page
Baxi launches its most famous product:
the Bermuda gas-fired back boiler
1983
Efficiency
Technical specifications 24-25
All Baxi boilers are Energy Saving Trust recommended, helping
households to save money on their gas bills.
What’s inside the boiler?
26
Flues 27
Baxi Bermuda
BBU HE
Features and benefits We are there for you – providing practical training, technical help and
genuine parts – when you need us.
2001
A period of acquisitions sees Baxi purchasing
Ocean Idroclima and the Blue Circle Heating Division
The Baxi 105 E becomes the
UK’s biggest-selling combi boiler
2006
page
28
Accessories29
The Baxi Solo – a low-weight
cast iron boiler – is launched
1999
22
Accessories23
Support
1989
Baxi is sold to its workforce, becoming the
UK’s largest employee partnership of its kind
page
Easy to install
Our boilers come with a pre-plumbing jig, complete with preformed
copper pipe tails, built-in filling loop and one metre mains cable to save
you time and money during installation.
The award-winning Baxi
Duo-tec Combi HE is launched
2010
The UK’s first domestic, wall-hung
micro-CHP appliance, Baxi Ecogen, is launched
2012
Technical specifications 30-31
What’s inside the boiler? 32
Flues 33
Flue solutions
page
Vertical flue systems
34-35
Horizontal flue systems
35-36
Plume displacement kits
36
Twin flue systems
37
Baxi Bermuda BBU HE
37
Additional services
Baxi Ecogen wins the
Queen’s Award for Enterprise in Innovation
How we can help page 3
page
38-39
I regularly recommend the Platinum
HE A. The 10 year warranty means
customers trust the product and
I know that it won’t let them down.
Simon Harrington
Harrington Plumbing & Heating
Baxi Platinum
Combi HE A
The Baxi Platinum Combi HE A is our top of the range boiler. A firm favourite
with householders and installers alike, it’s an Energy Saving Trust recommended
product, so you can be sure of its excellent energy efficiency.
Total peace of mind
The Baxi Platinum Combi HE A comes with an impressive 10 year warranty*.
Accessories
The following accessories are compatible with the Baxi Platinum Combi HE A
10
yr
WARRANTY*
page 5
BUILT-IN
TIMER
BUILT-IN
FILLING
LOOP
EXTENSIVE
FLUE
OPTIONS
Key features
Benefits
Outputs: 24kW, 28kW, 33kW and 40kW
A model to suit most styles and sizes of property
Pre-plumbing jig, with built-in filling loop and preformed copper tails
Easy to install and maintain, saving time and money
Built-in mechanical 24 hour timer
Easy to set and control
Built-in frost thermostat
Suitable for siting in garages and lofts
Front access to all components
Easy to service and maintain
Exceptional flow rate (up to 16.4 litres per minute) at a rise of 35ºC
Ideal for homes with more than one bathroom
Compatible with Multifit flue kits
Industry-leading choice of lengths, bends and accessories
page 6
Baxi qSense digital
room thermostat
Baxi programmable 24
hour wireless sensor
Baxi seven day
programmable room
thermostat
Baxi room
thermostat
Baxi wired weather
sensor
Multifit GasSaver
GS1
*Subject to registration and an annual service. Available until 31st December 2014.
Terms and conditions apply. For full details visit baxi.co.uk/warranty
Technical details
Baxi Platinum Combi HE A
Technical
specifications
Baxi Platinum Combi HE A
HOW WE MAKE IT EASY
Sales code
Pre-plumbing
jig for quick and
simple installation.
Controls
Concealed user controls
On/off switch with reset
User adjustable DHW temperature
User adjustable CH temperature
LED temp/status/fault diagnosis display
Integral 24 hour electro-mechanical timer
24 HE A
28 HE A
33 HE A
40 HE A
5116062
5116203
5116205
5121682
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2 digits/3 LEDs
2 digits/3 LEDs
2 digits/3 LEDs
2 digits/3 LEDs
Fitted as standard
Fitted as standard
Fitted as standard
Fitted as standard
22
22
22
22
3
3
3
3
20
20
20
Gas
A
D
Boiler dimensions
E
D
Gas supply pipe size
Natural gas
mm
Nominal inlet supply pressure
Maximum gas rate
Heat input central heating
mbar
20
m3/hr
2.61
3.10
3.6
4.36
kW max gross
22.7
27.4
32.1
36.4
kW max net
20.5
24.7
28.9
32.8
kW min gross
7.8
10.0
10.8
11.0
kW min net
7.0
9.0
9.7
9.9
Heat output CH non condensing
(70° mean water temp)
kW max
20
24
28
32
kW min
6.8
8.7
9.4
9.6
Heat output CH condensing
(40° mean water temp)
kW max
21.0
25.9
30.3
34.4
kW min
7.4
9.5
10.2
12.1
Heat input domestic hot water
(DHW)
kW max gross
27.4
32.1
37.7
45.7
kW max net
24.7
28.9
34 .0
41.2
Heat output domestic hot water
Maximum domestic hot water flow rate
Seasonal efficiency
SEDBUK (2005) rating
NOx class
kW max
24
28
33
40
l/min @ 35°C rise
9.8
11.5
13.5
16.4
91.1
91.1
91.1
91.1
A
A
A
A
5
5
5
5
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
3
3
3
3
A Boiler width = 450mm
height
Height [B]B Boiler
Depth
[C] = 780mm
C Boiler depth = 345mm
450mm780mm
345mm = 5mm*
D Side clearance
E Upper clearance = 200mm* (300mm*
if using 80/125mm flueing system)
F Lower clearance = 150mm*
G Front clearance = 5mm* in operation,
450mm* for servicing purposes
Side [D]
Upper [E] Lower [F]
Front [G]
Width [A]
Service clearances
5mm*200mm* (*300 if using B
G
150mm*
5mm in
operation*,
%
Electrical
Electrical supply
Permanent live required
80/125 flueing *450 for servicing
system)
purposes
Volts/Hz
Fitted electrical cable
Power consumption
External fuse rating
Internal fuse rating
Ingress protection rating
(without electro-mechanical timer fitted)
24 hour pump exercise
These are the minimum recommended dimensions.
Greater clearance will aid installation and maintenance.
*
* These are the MINIMUM recommended
dimensions. Greater clearance will
aid installation and maintenance.
1m x 3 core x 0.75mm2 on all models
Watts
155
155
160
Amps
3
3
3
3
Amps
F2L
F2L
F2L
F2L
IPX 5D
IPX 5D
IPX 5D
IPX 5D
3
3
3
3
3
3
3
3
3
3
3
3
None
None
None
None
3
3
3
3
Pump overrun
Integral ‘boiler only’ frost thermostat
C
F
160
Mechanical and hydraulic
Compartment ventilation requirement
Pre-plumbing/wall mounting jig
What’s in the box?
Flow and return pipe size
Condensate discharge pipe size
Integral automatic bypass
mm
22
22
22
22
mm
21.5
21.5
21.5
21.5
3
3
3
3
Min domestic hot water flow rate
Min domestic hot water operating pressure
Maximum DHW system pressure
Safety discharge pressure
Integral expansion vessel capacity
Max capacity of central heating system
Temporary filling loop included
l/min
2
2
2
2
bar
0.15
0.15
0.15
0.15
bar
8
8
8
8
bar
3
3
3
3
litres
8
8
10
10
litres
125
125
155
155
3
3
3
3
3
3
3
3
315 - 500
CH system inhibitor required
Concentric flue system
Standard telescopic horizontal flue kit length
Max equiv length horizontal/vertical (60/100mm)
Max equiv length horizontal/vertical (80/125mm)
Equivalent length per 135º bend
Equivalent length per 93º bend
Platinum Combi HE A boiler
Pre-plumbing jig
Fitting instructions,
template, user
instructions, warranty
Filling loop
Copper
pipe tails
mm
315 - 500
315 - 500
315 - 500
m
10
10
10
10
m
20
20
20
20
m
0.5
0.5
0.5
0.5
m
1
1
1
1
mm
80/80
80/80
80/80
80/80
m
15/15
15/15
15/15
15/15
m
0.25
0.25
0.25
0.25
m
0.5
0.5
0.5
0.5
kg
43.6
44.2
45
45
kg
48.6
49.2
50
50
Twin pipe flue system
Diameters
Max equiv length horizontal/vertical (parallel pipes)
Equivalent length per 135° bend
Equivalent length per 91.5° Bend
Weights
Max installation lift weight
Gross packaged boiler weight
page 7
page 8
What’s inside the boiler?
Flues
Baxi Platinum Combi HE A
These are the flues that are most frequently installed with the Baxi Platinum Combi HE A.
For the full range, see pages 34-37.
Horizontal flue system
Flue connection
GROUP A | Concentric horizontal flue system | 60/100mm diameter
Igniter
Key
Expansion vessel
Spark electrode
Combustion box cover and burner
Stainless steel heat exchanger
Flame sensing electrode
Item description
Specification
OD dimensions Multifit
sales code
Standard horizontal
telescopic flue (inc elbow)
315mm - 500mm 60/100mm
5118069
Standard horizontal
flue (inc elbow)
685mm
60/100mm
5118489
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in
accordance with the installation instructions.
Air/gas collector
Fan assembly
Vertical flue system
Venturi
GROUP A | Concentric vertical flue system | 60/100mm diameter
Condensate trap (behind)
Key
Item description
Specification
Gas valve
Vertical flue terminal
Pump
PCB housing
Diverter valve (behind)
OD dimensions Multifit
sales code
100mm
5118576
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
Pressure relief valve
*Pitched roof and flat roof flashing available – see page 34
Pressure gauge
Integral clock
Plume displacement kits
GROUP K | Plume displacement kits | 60/100mm diameter
Key
HOW WE MAKE IT EASY
Multifit flue kits offer
an industry-leading
choice of accessories.
page 9
Item description
Specification
Plume displacement kit
(inc elbow and clips)
100mm
Plume displacement kit
(extension inc clip)
1000mm
OD dimensions Multifit
sales code
5118638
60mm
5121368
page 10
I regularly specify the Duo-tec HE A
boiler. It is easy for my customers to use
with its clear display and large symbols.
It has always been extremely reliable
and the seven year warranty is brilliant.
Mark Webley
Webley Heating
Baxi Duo-tec
Combi HE A
Our best selling Baxi Duo-tec Combi HE A has a pre-plumbing jig, complete
with preformed copper pipe tails, built-in filling loop and one metre mains
cable, making it quick and easy to install.
Total peace of mind
The Baxi Duo-tec Combi HE A has proven reliability, which is why it comes with
a 7 year warranty*.
Accessories
The following accessories are compatible with the Baxi Duo-tec Combi HE A.
7
yr
WARRANTY*
COMPACT
CASE
DIMENSIONS
BUILT-IN
FILLING
LOOP
LPG
MODEL
AVAILABLE
Baxi qSense digital
room thermostat
page 11
Key features
Benefits
Outputs: 24kW, 28kW, 33kW and 40kW
A model to suit most styles and sizes of property
Pre-plumbing jig, with built-in filling loop
Easy to install and maintain
Built-in frost thermostat
Suitable for siting in garages and lofts
Class leading flow rate (up to 16.4 litres per minute) at 35°C rise
Perfect for homes with more than one bathroom
Dedicated 28kW LPG model
Suitable for homes without mains gas
Telescopic horizontal flue available
Quick and easy to fit
Compatible with Multifit flue kits
Industry-leading choice of lengths, bends, accessories
Baxi electromechanical 24 hour
timer kit
Multifit GasSaver
GS1
Baxi room
thermostat
*Subject to registration and an annual service. Available until 31st December 2014.
Terms and conditions apply. For full details visit baxi.co.uk/warranty
page 12
Technical details
Baxi Duo-tec Combi HE A
Technical
specifications
Baxi Duo-tec Combi HE A
HOW WE MAKE IT EASY
Sales Code
Pre-plumbing
jig for quick and
simple installation.
24 HE A
28 HE A
33 HE A
40 HE A
5118060
5118646
5118062
5121342
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2 digits/3 LEDs
2 digits/3 LEDs
2 digits/3 LEDs
2 digits/3 LEDs
22
22
22
22
3
3
3
3
N/A
3
N/A
N/A
Controls
Concealed user controls
On/off switch with reset
User adjustable DHW temperature
User adjustable CH temperature
LED temp/status/fault diagnosis display
Gas
Gas supply pipe size
mm
Natural gas
LPG (propane)
A
D
Boiler dimensions
E
D
A Boiler width = 450mm
height = 780mm
Width [A]
Height [B]B Boiler
Depth
[C]
C Boiler depth = 345mm
450mm780mm
345mm = 5mm*
D Side clearance
E Upper clearance = 200mm* (300mm*
if using 80/125mm flueing system)
F Lower clearance = 150mm*
G Front clearance = 5mm* in operation,
450mm* for servicing purposes
Upper [E] Lower [F]
Front [G]
Service clearances
Side [D]
5mm*200mm* (*300 if using B
mbar
20
20
20
20
Maximum gas rate NG
m3/hr
2.61
3.10
3.6
4.36
Heat input central heating
kW max gross
22.7
27.4
32.1
36.4
kW max net
20.5
24.7
28.9
32.8
kW min gross
7.8
10 .0
10.8
11.0
kW min net
7.0
9.0
9.7
9.9
Heat output CH non condensing
kW max
20
24
28
32
(70° mean water temp)
kW min
6.8
8.7
9.4
9.6
Heat output CH condensing
kW max
21.0
25.9
30.3
34.4
(40° mean water temp)
kW min
7.4
9.5
10.2
12.1
Heat input domestic hot water
kW max gross
27.4
32.1
37.7
45.7
(DHW)
kW max net
24.7
28.9
34.0
41.2
Heat output domestic hot water
kW max
24
28
33
40
Maximum domestic hot water flow rate
l/min @ 35°c rise
9.8
11.5
13.5
16.4
Seasonal efficiency NG
%
91.1
91.1
91.1
91.1
SEDBUK (2005) rating
Band
A
A
A
A
5
5
5
5
mg/kWhr
22.3
26.0
21.8
25.2
Volts/Hz
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
3
3
3
3
NOx Class
G
150mm*
5mm in
operation*,
Nominal inlet supply pressure NG
NOx levels
Electrical
80/125 flueing *450 for servicing
system)
purposes
Electrical supply
Permanent live required
Fitted electrical cable
These are the minimum recommended dimensions.
Greater clearance will aid installation and maintenance.
*
* These are the MINIMUM recommended
dimensions. Greater clearance will
aid installation and maintenance.
1m x 3 core x 0.75mm2 on all models
Power consumption
Watts
155
155
160
External fuse rating
Amps
3
3
3
3
Internal fuse rating
Amps
F2L
F2L
F2L
F2L
IPX 5D
IPX 5D
IPX 5D
IPX 5D
3
3
3
3
3
3
3
3
3
3
3
3
None
None
None
None
3
3
3
3
Ingress protection rating (without electro-mechanical timer fitted)
24 hour pump exercise
Pump overrun
Integral ‘boiler only’ frost thermostat
C
F
160
Mechanical and hydraulic
Compartment ventilation requirement
What’s in the box?
Pre-plumbing/wall mounting jig
Flow and return pipe size
mm
22
22
22
22
Condensate discharge pipe size
mm
21.5
21.5
21.5
21.5
3
3
3
3
2
2
2
2
Integral automatic bypass
Min domestic hot water flow rate
l/min
Min domestic hot water operating pressure
bar
0.15
0.15
0.15
0.15
Maximum DHW system pressure
bar
8
8
8
8
Safety discharge pressure
bar
3
3
3
3
Integral expansion vessel capacity
litres
8
8
10
10
Max capacity of central heating system
litres
125
125
155
155
3
3
3
3
3
3
3
3
315 - 500
Filling loop included
CH system inhibitor required
Concentric Flue System
Duo-tec Combi HE A boiler
Pre-plumbing jig
Fitting instructions,
template, user
instructions, warranty
Filling loop
Copper
pipe tails
Standard telescopic horizontal flue kit length
mm
315 - 500
315 - 500
315 - 500
Max equiv length horizontal/vertical (60/100mm)
m
10
10
10
10
Max equiv length horizontal/vertical (80/125mm)
m
20
20
20
20
Equivalent length per 135º bend
m
0.5
0.5
0.5
0.5
Equivalent length per 93º bend
m
1
1
1
1
Twin pipe flue system
Diameters
mm
80/80
80/80
80/80
80/80
Max equiv length horizontal/vertical (parallel pipes)
m
15/15
15/15
15/15
15/15
Equivalent length per 135° bend
m
0.25
0.25
0.25
0.25
Equivalent length per 91.5° Bend
m
0.5
0.5
0.5
0.5
Weights
page 13
Max installation lift weight
kg
43.6
44.2
46
46
Gross packaged boiler weight
kg
48.6
49.2
51
51
page 14
What’s inside the boiler?
Flues
Baxi Duo-tec Combi HE A
These are the flues that are most frequently installed with the Baxi Duo-tec Combi HE A.
For the full range, see pages 34-37.
Horizontal flue system
GROUP A | Concentric horizontal flue system | 60/100mm diameter
Igniter
Key
Expansion vessel
Spark electrode
Combustion box cover and burner
Stainless steel heat exchanger
Flame sensing electrode
Item description
Specification
OD dimensions Multifit
sales code
Standard horizontal
telescopic flue (inc elbow)
315mm - 500mm 60/100mm
5118069
Standard horizontal
flue (inc elbow)
685mm
60/100mm
5118489
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in
accordance with the installation instructions.
Air/gas collector
Vertical flue system
Venturi
GROUP A | Concentric vertical flue system | 60/100mm diameter
Condensate trap (behind)
Key
Item description
Specification
Vertical flue terminal
Pump
OD dimensions Multifit
sales code
100mm
5118576
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
Pressure relief valve
*Pitched roof and flat roof flashing available – see page 34
Plume displacement kits
GROUP K | Plume displacement kits | 60/100mm diameter
Key
HOW WE MAKE IT EASY
Telescopic horizontal
flue option is quick
and easy to fit.
page 15
Item description
Specification
Plume displacement kit
(inc elbow and clips)
100mm
Plume displacement kit
(extension inc clip)
1000mm
OD dimensions Multifit
sales code
5118638
60mm
5121368
page 16
I regularly install the Megaflo HE A
boiler. It is a great boiler, easy to
work on and good value for money.
Jack Sowden
Royston Engineering
Baxi Megaflo
System HE A
Designed for fully pumped sealed systems, the Baxi Megaflo System HE A
can be installed with an unvented cylinder. It will satisfy the hot water
and heating requirements of most homes, including larger properties with
more than one bathroom.
Total peace of mind
The Baxi Megaflo System HE A has proven reliability, which is why it comes
with a 7 year warranty*.
Accessories
The following accessories are compatible with the Baxi Megaflo System HE A
7
yr
WARRANTY*
page 17
FULLY
MODULATING
OUTPUTS
PRE-PLUMBING
JIG
SUPPLIED
INTEGRAL
AUTOMATIC
BYPASS
Key features
Benefits
Outputs: 15kW, 18kW, 24kW, 28kW and 32kW
A model to suit most styles and sizes of property
Pre-plumbing jig, with built-in filling loop
Easy to install and maintain
Easy to use built-in timer
Easy to set and control
Built-in frost thermostat
Suitable for siting in garages and lofts
Integral automatic bypass
Suitable for systems with TVRs on every radiator
Compatible with Multifit flue kits
Industry-leading choice of lengths, bends, accessories
Compatible with the market-leading Megaflo cylinders
Made by our sister company Heatrae Sadia
Suitable for use with Baxi Solarflo solar thermal
Hot water from solar energy reduces energy bills
Megaflo Eco
unvented cylinder
Baxi Solarflo
*Subject to registration and an annual service. Available until 31st December 2014.
Terms and conditions apply. For full details visit baxi.co.uk/warranty
page 18
Technical details
Baxi Megaflo System HE A
Technical
specifications
HOW WE MAKE IT EASY
Front access to
all components
makes servicing
simple.
Baxi Megaflo System HE A
15 HE A 18 HE A 24HE A 28 HE A 32 HE A
Sales code
Concealed user controls
On/off switch with reset
User adjustable CH temperature
Boiler dimensions
E
E Upper clearance = 200mm* (300mm*
if using 80/125mm flueing system)
F Lower clearance = 200mm*
G Front clearance = 5mm* in operation,
450mm* for servicing purposes
Upper [E] Lower [F]
Front [G]
Side [D]
5mm*200mm* (*300 if using 5121345
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
22
2 digits/3 LEDs on all models
mm
22
22
22
22
3
3
3
3
3
20
20
20
20
mbar
20
Maximum gas rate NG
m3/hr
1.69
1.95
2.61
3.10
3.48
Heat input central heating
kW max gross
17.1
20.5
27.4
32.1
36.4
kW max net
15.4
18.5
24.7
28.9
32.8
kW min gross
4.4
4.8
7.8
10.8
10.8
kW min net
4.0
4.3
7.0
9.7
9.7
kW max
15
18
24
28
32
kW min
3.9
4.2
6.8
9.4
9.4
Heat output CH condensing
(40° mean water temp)
kW max
16.2
19.4
25.9
30.3
34.4
kW min
4.2
4.5
7.4
10.2
10.2
Seasonal efficiency
%
91.2
91.2
91.2
91.2
91.2
SEDBUK (2005) rating
A
A
A
A
A
NOx class
5
5
5
5
5
mg/kWhr
27.5
31.7
22.3
21.8
26.8
Volts/Hz
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
3
3
3
3
3
160
Heat output CH non condensing
(70° Mean Water temp)
Service clearances
5118648
Nominal inlet supply pressure
D
A Boiler width = 450mm
B Boiler height = 780mm
Width [A]
Height [B] Depth [C]
C Boiler depth = 345mm
450mm780mm
345mm = 5mm*
D Side clearance
5118063
Gas
Natural gas
D
5121344
LED temp/status/fault diagnosis display
Gas supply pipe size
A
5121343
Controls
NOx levels
Electrical
B
Electrical supply
Permanent live required
G
150mm*
5mm in
operation*,
Fitted electrical cable
80/125 flueing *450 for servicing
system)
purposes
1m x 3 core x 0.75mm2 on all models
Power consumption
Watts
130
140
150
160
External fuse rating
Amps
3
3
3
3
3
Internal fuse rating
Amps
F2L
F2L
F2L
F2L
F2L
IPX 5D
IPX 5D
IPX 5D
IPX 5D
IPX 5D
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
None
None
None
None
None
3
3
3
3
3
Ingress protection rating
(without electro-mechanical timer fitted)
These are the minimum recommended dimensions.
Greater clearance will aid installation and maintenance.
*
24 hour pump exercise
* These are the MINIMUM recommended
dimensions. Greater clearance will
aid installation and maintenance.
Pump overrun
Integral ‘boiler only’ frost thermostat
Mechanical and hydraulic
C
F
What’s in the box?
Compartment ventilation requirement
Pre-plumbing/wall mounting jig
Flow and return pipe size
mm
22
22
22
22
22
Condensate discharge pipe size
mm
21.5
21.5
21.5
21.5
21.5
3
3
3
3
3
Integral automatic bypass
Safety discharge pressure
bar
3
3
3
3
3
Integral expansion vessel
litres
8
8
8
10
10
Max capacity of central heating system
litres
125
125
125
125
125
3
3
3
3
3
315 - 500
CH system inhibitor required
Concentric Flue System
Standard telescopic horizontal flue kit length
mm
315 - 500
315 - 500
315 - 500
315 - 500
Max equiv length horizontal/vertical (60/100mm)
m
10
10
10
10
10
Max equiv length horizontal/vertical (80/125mm)
m
20
20
20
20
20
Equivalent length per 135º bend
m
0.5
0.5
0.5
0.5
0.5
Equivalent length per 93º bend
m
1
1
1
1
1
Twin pipe flue system
Diameters
mm
80/80
80/80
80/80
80/80
80/80
Max equiv length horizontal/vertical (parallel pipes)
m
15/15
15/15
15/15
15/15
15/15
Equivalent length per 135° bend
m
0.25
0.25
0.25
0.25
0.25
Equivalent length per 91.5° Bend
m
0.5
0.5
0.5
0.5
0.5
Max installation lift weight
kg
38.6
38.6
39.2
41
41
Gross packaged boiler weight
kg
43.6
43.6
44.2
46
46
Weights
Megaflo System HE A boiler
page 19
Pre-plumbing jig
Fitting instructions,
template, user
instructions, warranty
Copper
pipe tails
page 20
What’s inside the boiler?
Flues
Baxi Megaflo System HE A
These are the flues that are most frequently installed with the Baxi Megaflo System HE A.
For the full range, see pages 34-37.
Horizontal flue system
GROUP A | Concentric horizontal flue system | 60/100mm diameter
Igniter
Key
Expansion vessel
Spark electrode
Combustion box cover and burner
Stainless steel heat exchanger
Flame sensing electrode
Item description
Specification
OD dimensions Multifit
sales code
Standard horizontal
telescopic flue (inc elbow)
315mm - 500mm 60/100mm
5118069
Standard horizontal
flue (inc elbow)
685mm
60/100mm
5118489
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in
accordance with the installation instructions.
Air/gas collector
Fan assembly
Vertical flue system
Venturi
GROUP A | Concentric vertical flue system | 60/100mm diameter
Condensate trap (behind)
Key
Item description
Specification
Vertical flue terminal
Pump
Pressure relief valve
OD dimensions Multifit
sales code
100mm
5118576
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
*Pitched roof and flat roof flashing available – see page 34
Pressure gauge
Plume displacement kits
GROUP K | Plume displacement kits | 60/100mm diameter
Key
HOW WE MAKE IT EASY
Telescopic horizontal
flue option is quick
and easy to fit.
page 21
Item description
Specification
Plume displacement kit
(inc elbow and clips)
100mm
Plume displacement kit
(extension inc clip)
1000mm
OD dimensions Multifit
sales code
5118638
60mm
5121368
page 22
The Solo HE A is very reliable
and the pump overrun is really
handy when retrofitting the
boiler into an older house.
Carl Broadbent
Agoura Heating
Baxi Solo
Heat Only HE A
Lightweight and compact enough to fit into a standard kitchen cupboard, the
Baxi Solo HE A is so stylish it will fit in with any modern interior. It is an Energy
Saving Trust recommended product. Simple controls make it extremely easy
to use.
Easy to install
The Baxi Solo HE A does not need a pump overrun so it can replace an old heat only
boiler with minimum disruption to the householder.
Accessories
The following accessories are compatible with the Baxi Solo HE A
2yr
WARRANTY*
page 23
COMPACT
DESIGN
NO PUMP
OVERRUN
REQUIRED
FULLY
MODULATING
OUTPUTS
Key features
Benefits
Outputs: 12kW, 15kW, 18kW, 24kW and 30kW
A model to suit most styles and sizes of property
Lightweight and compact
Perfect for applications where space is limited
Pre-plumbing jig, with built-in filling loop
Easy to install and maintain
No pump overrun required
Installed with minimal disruption to the householder
For use on open vented or sealed heating systems
Compatible with most existing heating systems
Front access to all components
Straightforward servicing and maintenance
Simple controls
Easy to set and control
Compatible with Multifit flue kits
Industry-leading choice of lengths, bends, accessories
Baxi room thermostat
Baxi qSense digital
room thermostat
Baxi Solarflo
Megaflo Eco SystemFit
Baxi seven day
programmable room
thermostat
* Subject to registration and an annual service. Terms and conditions apply.
page 24
Baxi Solo HE A
Technical
specifications
Technical details
HOW WE MAKE IT EASY
Front access to
all components
makes servicing
simple.
Baxi Solo HE A
12 HE A 15 HE A 18 HE A 24 HE A 30 HE A
Sales code
5120295
5117783
5120296
5117784
5117785
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
15
15
15
15
15
3
3
3
3
3
20
20
20
2.95
Controls
Concealed user controls
User adjustable CH temperature
LED status/fault diagnosis display
Gas
Gas supply pipe size
A
Boiler dimensions
E
D
D
A Boiler width = 390mm
Depth [C]
B Boiler height = 600mm
390mm600mm
298mm
C Boiler depth
= 298mm
D Side clearance = 5mm*
E Upper clearance = 200mm*
F Lower clearance = 50mm*
G Front clearance = 5mm* in operation,
for[F]
servicingFront
purposes
Side [D]
Upper [E]500mm*
Lower
[G]
Width [A]
Height [B] 150mm*
5mm in
operation*,
Nominal inlet supply pressure
mbar
20
20
Maximum gas rate
m3/hr
1.34
1.64
1.94
2.31
Heat input central heating
kW max gross
13.3
16.9
20.2
24.5
33.8
kW max net
12.0
15.2
18.2
22.1
30.4
30.2
Heat output CH non condensing
kW max
11.8
15.2
17.8
22.0
Heat output CH condensing
kW max
12.8
16.5
19.3
23.8
32.6
Seasonal efficiency
%
90.5
91.3
90.4
90.9
90.9
SEDBUK (2005) rating
Band
A
A
A
A
A
5
5
5
5
5
mg/kWhr
13.1
29.0
11.7
37.0
48.0
Volts/Hz
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
7
7
7
7
7
80
NOx class
NOx levels
Service clearances
5mm*200mm* (*300 if using mm
Natural gas
Electrical
Electrical supply
Permanent live required
Electrical cable required
B
G
80/125 flueing *450 for servicing
system)
purposes
1m x 3 core x 0.75mm2 on all models
Power consumption
Watts
80
80
80
80
External fuse rating
Amps
3
3
3
3
3
Internal fuse rating
Amps
3.15
3.15
3.15
3.15
3.15
IPX2
IPX2
IPX2
IPX2
IPX2
7
7
7
7
7
7
7
7
7
7
None
Ingress protection rating
(without electro-mechanical timer fitted)
Pump overrun
These are the minimum recommended dimensions.
Greater clearance will aid installation and maintenance.
*
Integral ‘boiler only’ frost thermostat
Mechanical and hydraulic
Compartment ventilation requirement
* These are the MINIMUM recommended
dimensions. Greater clearance will
aid installation and maintenance.
None
None
None
None
Flow and return pipe size
mm
22
22
22
22
22
Condensate discharge pipe connection
mm
21.5
21.5
21.5
21.5
21.5
7
7
7
7
7
3
3
Bypass required
Vertical pipe route
C
F
What’s in the box?
Within case on all models
CH system inhibitor required
3
3
3
Concentric flue system
Outside diameter
mm
110
110
110
110
110
Standard horizontal flue kit length
mm
850
850
850
850
850
Max equivalent length horizontal
m
Max equivalent length vertical
m
Equivalent length per 135º bend
m
0.5
0.5
0.5
0.5
0.5
Equivalent length per 93º bend
m
1
1
1
1
1
4 plus terminal on all models
4 plus terminal on all models
Twin pipe flue system
Diameters
mm
80/80
80/80
80/80
80/80
80/80
Max equiv length horizontal (parallel pipes)
m
75
75
75
75
75
Max equivalent length vertical (parallel pipes)
m
75
75
75
75
75
Equivalent length per 135° bend
m
1.3 air and 2.6 flue on all models
Equivalent length per 90° bend
m
4.8 air and 9.6 flue on all models
Weights
Solo HE A boiler
page 25
Wall mounting plate
Fitting instructions,
template, user
instructions, warranty
Max installation lift weight
kg
26
26
26
26
26
Gross packaged boiler weight
kg
36.2
36.2
36.2
36.2
36.2
Fittings
pack
page 26
What’s inside the boiler?
Flues
Baxi Solo HE A
These are the flues that are most frequently installed with the Baxi Solo HE A.
For the full range, see pages 34-37.
Horizontal flue system
GROUP B | Concentric horizontal flue system | 70/110mm diameter
Return pipe connection (behind)
Key
Flow switch
Flow pipe connection
Heat exchanger
Wiring terminal
Item description
Specification
OD dimensions Multifit
sales code
Standard horizontal flue
(inc elbow)
850mm
110mm
236921
Flue extension
1000mm
100mm
241695
Flue bend
93º
100mm
241687
Flue bend (pair)
135º
100mm
241689
NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in
accordance with the installation instructions.
Burner
Gas valve (behind)
Vertical flue system
Airbox
GROUP B | Concentric vertical flue system | 70/110mm diameter
Fan protection thermostat
Key
Fan assembly
Item description
Specification
Vertical roof terminal
Condensate trap
PCB housing
OD dimensions Multifit
sales code
70/110mm
242802
Flue extension
1000mm
110mm
241695
Flue bend
93º
110mm
241687
Flue bend (pair)
135º
110mm
241689
*Pitched roof and flat roof flashing available – see page 34
Plume displacement kits
GROUP L | Plume displacement kits | 70/110mm diameter
Key
HOW WE MAKE IT EASY
Fits both open
vented or sealed
heating systems.
page 27
Item description
Specification
Plume displacement kit
(inc elbow and clips)
Plume displacement kit
(extension inc clip)
1000mm
OD dimensions Multifit
sales code
110mm
5121371
70mm
5121372
page 28
We maintain a number of Bermuda
boilers. They’re very reliable and
require minimal fuss during the
installation process as they fit in
easily behind the fireplace.
Carl Broadbent
Agoura Heating
Baxi Bermuda
BBU HE
Made by Baxi, the inventors of the original back boiler, the Baxi Bermuda BBU HE
is the only high efficiency boiler to act as a direct replacement. Fitting a like for like
boiler minimises disruption and saves valuable living space.
Total peace of mind
The Baxi Bermuda BBU HE comes with a 2 year parts and labour warranty*.
Accessories
The following accessories are compatible with the Baxi Bermuda BBU HE.
2
yr
WARRANTY*
page 29
ROOM
SEALED
APPLIANCE
NO PUMP
OVERRUN
REQUIRED
SINGLE
PIECE
FLUE
Key features
Benefits
15kW modulating heat output
Optimum performance at all times
Room sealed appliance
No air vents required
Built-in condensate pump and no pump overrun required
Installed with minimal disruption to the customer
Gas valve is factory set
Quick and simple commissioning
Single piece flexible concentric flue
No flue inspection access required
Like for like replacement
No loss of valuable space for householder
No need to re-site the boiler or modify pipework
No major disruption or redecoration
Complies with legislation and building regulations
No special paperwork or permission required
Megaflo Eco
Solar cylinder
Megaflo Eco
Systemfit cylinder
Baxi Solarflo
Range of fire fronts
*Subject to registration and an annual service. Terms and conditions apply.
page 30
Baxi Bermuda BBU HE
– nodepth
need
for airincluding
vents.
C Boiler
= 330mm
flue sampling point
Opening
Baxi Bermuda
BBU HE
Builders
Sales Code
630mm min
Controls
A
Concealed userFireplace
controls
Opening
User adjustable CH temperature
LED status/fault diagnosis display
Width [A]
Height [B] 3
Factory preset
3
Gas
Boiler dimensions
Gas supply pipe490mm
size
Natural gas
Depth [C]
15mm
compression
mm
560mm min
LPG (butane/propane)
430mm550mm 330mm
Nominal inlet supply pressure
m /hr
Heat output CH non condensing
Heat output CH condensing
Seasonal efficiency
Solid, non combustible
SEDBUK (2005)
rating
hearth
to support the boiler,
HEARTH
595m m
(R
O NLY - 575m m )
Fireplace
Opening
630m m m in hei gh t
insid e b u ild ers op en in g
kW max net
To accommodate the fire front without the need for additional
Builders
spacers, there must Opening
be a gap of at least 95mm from the surround or
finished face to the front of the boiler.
630mm min
ent
kW max gross
If necessary, this gap can be increased by the use of spacer kits.
Each spacer increases the effective depth of the opening by up to
50mm. Alternatively, a range of rebated fire surrounds are available.
LEVEL
kW max
15
kW max
15.7
0.1
Band
A
NOx class
5
NOx levels
mg/kWh
4 core wire
Power consumption
Watts
External fuse rating
Amps
3
Internal fuse rating
Amps
3.15
31
112
24 hour pump exercise
3
Not required
Pump overrun
Compartment ventilation required
15.38
%9
3
Electrical cable required
Mechanical and hydraulic
17.1
230/50Hz
Permanent live required
7
1.63
Heat input central heating
B
Volts/Hz
Electrical supply
3
20
3
SURROUND OR FINISHED
Maximum gas rate
WALL FACE
Clearances
710153301
Electrical
595m m
(R
O NLY - 575m m )
Technical
specifications
Technical details
HOW width
WE MAKE
IT EASY
A Boiler
= 430mm
including connections and fittings
Room
sealed
appliance
B Boiler
height
= 550mm
including air vent
None
Flow and return pipe size
mm
Condensate discharge pipe connection
mm
22 male copper
10
Bypass required
Yes (pressure operated)
Vertical pipe route
No inverted pipework permitted
CH system inhibitor required
3
Concentric flue system
Outside diameter
mm
Max equivalent length vertical
m
100
10
Weights
Max installation lift weight
kg
27
Gross packaged boiler weight
kg
28
Accessories
Right hand plumb kit
Sales code
720111701
450mm min
400mm min (with spacer)
486mm min (Regalia ONLY)
When surveys highlight that space is restricted versus minimum site
490mm
requirements, the use of rebated surrounds is recommended.
560mm min
C
HEARTH
LEVEL
Solid, non combustible
hearth to support the boiler,
Fire – all measurements given in mm
490mm
450mm min
400mm min (with spacer)
486mm min (Regalia ONLY)
560mm min
C
What’s in the box?
HEARTH
LEVEL
Solid, non combustible
hearth to support the boiler,
Boiler
and fire
Fascia
height
Fascia
width
Dimension ™ Regalia BBU firefront+
05847A1
720331401
720
600
Dimension ™ Innova BBU firefront*
0584711
720331301
632
542
Dimension ™ Classica brass BBU firefront+
0584721
720330701
615
512
Dimension Classica pewter BBU firefront+
0584701
720330801
615
Dimension ™ Dream gold BBU firefront+
05847C1
720331001
636
Dimension ™ Dream chrome BBU firefront+
05847D1
720331101
636
Dimension ™ Lyrica BBU firefront+
0584511
720331601
Model
Part
number
Classica, Lyrica, Nano and Innova spacer kit
5135632
™
SURROUND OR FINISHED
WALL FACE
B
Fire
only
Model
630m m m in hei gh t
insid e b u ild ers op en in g
A
Fireplace
Opening
595m m
(R
O NLY - 575m m )
C Boiler depth = 330mm including
flue sampling point
Fire and accessories technical specifications
Builders
Opening
630mm min
630m m m in hei gh t
insid e b u ild ers op en in g
OR FINISHED
A SURROUND
Boiler width
= 430mm
WALL FACE
including connections and fittings
B Boiler height = 550mm including air vent
Fascia
depth
Engine
depth
Spacer
depth
45
144
50
38
144
50
51
144
50
512
51
144
50
518
79
144
50
518
79
144
50
612
510
74
144
50
Height
Width
Depth
Rebate
610
503
50
NA
Accessories – all measurements given in mm
450mm min
400mm min (with spacer)
486mm min (Regalia ONLY)
Regalia spacer kit
5135633
715
586
50
NA
Dream spacer kit
5135634
625
504
50
NA
Right hand plumb kit
BBU wall fascia^
720111701
NA
NA
NA
NA
05847H1
750
650
157
NA
+ This fire is floor standing only.
^ This fire can be wall mounted
or floor standing.
* For use with the Innova fire.
C
Bermuda BBU HE
page 31
Plumbing and fixing kit
Fitting instructions,
user instructions,
warranty
Condensate
pipe and elbow
page 32
What’s inside the boiler?
Flues
Baxi Bermuda BBU HE
Bermuda flue system
Automatic air vent
Flue connection
The Baxi Bermuda BBU HE is only suitable for use with the following flue kits:
Spark generator
(located behind PCB)
Key
Condensate outlet
Flow connection
Item description
Specification
OD dimensions Multifit
sales code
10m concentric flexible flue
Complete with
terminal
110mm
710143901
Flue pull cone*
Complete with
terminal
100mm
720111801
* The flue pull cone must be used for pulling the concentric flexible flue down the chimney.
The flue pull cone can then be retained for future installations.
Flue sampling point
Air sampling point
Spark and sensing electrodes
(located behind PCB)
PCB control box
Heat exchanger
(located behind PCB)
User interface connector
Control wiring connector
Return connection
Drain
Fan
Condensate pump
Gas cock
Condensate sump
HOW WE MAKE IT EASY
Single piece flue,
no inspection
access required.
page 33
page 34
Flue solutions
1. Baxi boilers can be fitted with flue systems as illustrated.
2. The standard flue is suitable only for horizontal termination applications.
3. Maximum permissible equivalent flue lengths for:
GROUP G
Concentric vertical flue system | 80/125mm diameter for use with Platinum HE A, Duo-tec HE A
and Megaflo HE A
4. Any additional “in line” bends in the flue system must be taken into
consideration. Their equivalent lengths for Platinum Combi HE A,
Duo‑tec Combi HE A, Megaflo system HE A and Solo HE A are:
• Platinum Combi HE A, Duo-tec Combi HE A and Megaflo system HE A
Horizontal concentric
Vertical concentric
Horizontal twin pipe
Vertical twin pipe
Group A
10m
10m
15m
15m
Group G
20m
20m
Concentric pipes
The elbow supplied with the boiler is not included in any equivalent
length calculations.
For Platinum HE A, Duo-tec HE A, Megaflo HE A
Twin flue pipe
4m
4m
75m (parallel pipes)
75m (parallel pipes)
Group G
0.5m
1m
• Solo HE A
Horizontal concentric
Vertical concentric
Horizontal twin pipe
Vertical twin pipe
Group A
135° bend
93° bend
Group A
135° bend
91.5° bend
Key
Not illustrated
Not illustrated
Group G
0.25m
0.50m
Not illustrated
Twin flue pipe
135° bend (air duct)
135° bend (flue duct)
91.5° bend (air duct)
91.5° bend (flue duct)
1.3m
2.6m
4.8m
9.6m
GROUP A
Not illustrated
Key
OD dimensions Multifit
sales code
5118576
Flue bend
91.5º
125mm
5118588
Flue bend (pair)
135º
125mm
5118597
125mm
5118610
125mm
5122151
Flat roof flashing
125mm
246144
Roof cover plate
125mm
246143
Pipe support
25/50º
Item description
Specification
OD
Multifit
dimensions sales code
Standard horizontal telescopic flue inc elbow 315mm - 500mm
60/100mm
5118069
Standard horizontal flue inc elbow
60/100mm
5118489
685mm
Telescopic internal flue kit
100mm
5119654
Flue extension
1000mm
100mm
5111074
Flue bend
93º
100mm
5111075
Flue bend (pair)
135º
100mm
5111085
Flue bend
135º
100mm
5111076
100mm
5111067
100mm
5111080
60mm
5111068
100mm
720550801
5111074
Flue bend (pair)
135º
100mm
5111085
Not illustrated
Flue internal fixing kit / wall liner
Pipe support
Flue terminal deflector
Low profile flue elbow
Painted white
Flue bend
93º
100mm
5111075
Not illustrated
Pipe support
Painted white
100mm
5111080
Not illustrated
125mm
5122151
NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in
accordance with the installation instructions.
Flat roof flashing
125mm
246144
Roof cover plate
125mm
246143
25/50º
93º
GROUP B
Item description
Concentric horizontal flue system | 70/110mm diameter for use with Solo HE A
Specification
OD dimensions Multifit
sales code
Vertical roof terminal
70/110mm
242802
Vertical flue adaptor (boiler)
110mm
5106888
Flue extension
1000mm
110mm
241695
Flue extension
500mm
110mm
241694
Flue extension
250m
110mm
241692
Flue bend
93º
110mm
241687
Flue bend (pair)
135º
110mm
241689
110mm
243014BAX
125mm
243015
125mm
243016BAX
Pipe support
Flat roof flashing
page 35
5118584
100mm
Pitched roof flashing
Not illustrated
125mm
1000mm
Concentric vertical flue system | 70/110mm diameter for use with Solo HE A
Not illustrated
1000mm
Flue extension
GROUP B
Key
Flue extension
Not illustrated
Pitched roof flashing
Not illustrated
5111070
Concentric horizontal flue system | 60/100mm diameter for use with Platinum HE A, Solo HE A, Duo-tec
HE A and Megaflo HE A
Not illustrated
100mm
5111078
100/125mm
GROUP A
Concentric horizontal flue system | 60/100mm diameter for use with Platinum HE A, Duo-tec HE A
and Megaflo HE A
Vertical flue terminal
125mm
Flue vertical adaptor
Horizontal flue system
Vertical flue system
Specification
OD dimensions Multifit
sales code
For Solo HE A
6. Instructions for guidance and fitting are included in each kit,
where appropriate.
Item description
Specification
Vertical flue terminal
Pitched roof flashing
5. The illustrations show examples of permissible flue systems.
Key
Item description
Roof cover plate
25/50º
243131
Key
Item description
Specification
OD
Multifit
dimensions sales code
Standard horizontal flue inc elbow
850mm
110mm
236921
Horizontal flue / wall terminal
850mm
110mm
243013BAX
Vertical flue adaptor (boiler)
110mm
5106888
Flue extension
1000mm
110mm
241695
Flue extension
500mm
110mm
241694
Flue extension
250m
110mm
241692
Flue bend
93º
110mm
241687
Flue bend (pair)
135º
110mm
241689
110mm
243014BAX
Not illustrated
Pipe support
Not illustrated
Flue terminal deflector
248167
NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance
with the installation instructions.
page 36
Flue solutions
Horizontal flue system (continued)
Twin flue system
GROUP G
GROUP N
Concentric horizontal flue system | 80/125mm diameter for use with Platinum HE A, Duo-tec HE A and
Megaflo HE A
Key
Item description
Specification
Horizontal flue inc boiler & terminal adaptor
Not illustrated
OD
Multifit
dimensions sales code
125mm
5118580
Twin flue system | 80/80mm diameter for use with Platinum HE A, Duo-tec HE A and Megaflo HE A
Key
Item description
Specification
OD
dimensions
Multifit
sales code
Twin pipe flue horizontal terminal kit
80mm
5120172
Vertical flue terminal
125mm
5111078
80/125mm
5111084
Flue extension
1000mm
125mm
5118584
Twin to concentric adaptor
Flue bend
91.5º
125mm
5118588
Twin pipe flue adaptor (boiler)
80/80mm
720089801
Flue bend (pair)
135º
125mm
5118597
Twin pipe extension (pair inc brackets) 1000mm
80mm
5111087
Twin pipe flue bend (pair)
90º
80mm
5111072
Twin pipe flue bend (pair)
135º
80mm
5111086
Twin pipe support (pair)
Painted white
80mm
5111081
Pitched roof flashing
25/50º
Pipe support
Painted white
125mm
5118610
Not illustrated
80/80 - 80/125
125mm
5122151
Not illustrated
Flat roof flashing
125mm
246144
Plume displacement kits
Not illustrated
Roof cover plate
100mm
246143
GROUP K
GROUP P
OD
dimensions
Multifit
sales code
Plume displacement kits | 60/100mm diameter for use with Platinum HE A, Duo-tec HE A,
Megaflo HE A
Key
Item description
Specification
Plume displacement kit
inc elbow and clips
100mm
Plume displacement kit
extension inc clip
1000mm
Key
OD dimensions Multifit
sales code
Item description
70/110mm
242802
850mm
110mm
243013BAX
Twin pipe flue extension
250mm
80mm
246135
Twin pipe flue extension
500mm
80mm
246136
Twin pipe flue extension
1000mm
80mm
246137
Horizontal / wall terminal
Twin pipe flue adaptor set
60mm
5121368
Plume displacement
kit bend
93º
60mm
5121369
Plume displacement
kit bend (pair)
135º
60mm
5121370
Plume displacement kits | 70/110mm diameter for use with Solo HE A
Specification
Plume displacement kit
inc elbow and clips
OD dimensions Multifit
sales code
110mm
5121371
Plume displacement kit
extension inc clip
1000mm
70mm
5121372
Plume displacement
kit bend
93º
70mm
5121373
Plume displacement
kit bend (pair)
135º
70mm
5121374
242757
Twin pipe flue bend (pair)
90º
80mm
5121560
Not illustrated
Twin pipe flue bend (pair)
135º
80mm
5121561
Not illustrated
Pipe support
110mm
243014BAX
Not illustrated
Twin pipe support (pair)
80mm
5111081
125mm
243015
Pitched roof flashing
Item description
Specification
Vertical roof terminal
5118638
GROUP L
Key
Twin flue system | 80/80mm diameter for use with Solo HE A
25/50º
Not illustrated
Flat roof flashing
243016BAX
Not illustrated
Flue terminal deflector
248167
Not illustrated
Roof cover plate
243131
Baxi Bermuda BBU HE
The Baxi Bermuda BBU HE is only suitable for use with the following flue kits:
Key
Item description
Specification
OD
dimensions
Multifit
sales code
10m concentric flexible flue
Complete with
terminal
100mm
710143901
Flue pull cone*
Complete with
terminal
100mm
720111801
*The flue pull cone must be used for pulling the concentric flexible flue down the chimney.
The flue pull cone can then be retained for future installations.
page 37
page 38
How we can help
Baxi Customer Support
Works
• Expert technical helpline
Sign up to works, Baxi’s online loyalty scheme for installers. Benefits include:
• UK based customer contact centre
• Free Gas Safe notification – save £2.20 + VAT on every registration
• Nationwide network of Gas Safe registered engineers
• Priority engineer call out and aftersales support
• Free annual service reminder sent to your customers on your behalf
• Find an Installer listing on the Baxi website to promote your business
Baxi Genuine Parts
• Great rewards – business points for every appliance you register
• Approved parts for Baxi products
Visit works2gether.co.uk to find out more
• Guaranteed quality, safety and reliability
• Nationwide network of approved stockists
• Lifetime support for Baxi products
Events
Visit Baxi Area Sales Managers at your local merchant for an opportunity to get your
hands on the latest Baxi boilers and discuss developments in the heating industry.
Training
For more information and to join us at a merchant local to you, visit baxievents.co.uk
• Practical, hands on training
• Free of charge product training
• A range of specialist courses
• Expert trainers, all accredited, former heating engineers
• Training centres across the UK
Visit baxi.co.uk/training
Literature
You can order all the literature you need for you and your customers, including:
• Range guides
• Product brochures for consumers
• Installation instructions
• User guides
• Instructions for discontinued products
Call the Baxi literature hotline on 0844 871 1525 or contact your
Baxi Area Sales Manager.
All our literature can be downloaded from our website baxi.co.uk
page 39
Useful
information
Technical helpline
0844 871 1525
Opening hours
Monday - Friday 8.00am - 6.00pm
Weekends and bank holidays 8.30am - 2.00pm
We are closed on Christmas Day and
New Year’s Day
Website
baxi.co.uk
Email
[email protected]
0844 871 1525
Opening hours
Address
Monday - Friday, 8.00am - 6.00pm
Weekends and bank holidays, 8.30am - 2.00pm
We are closed on Christmas Day and New Year’s Day.
Baxi
Please note calls may be monitored or recorded.
Brooks House
Coventry Road
Warwick
CV34 4LL
baxi.co.uk
[email protected]
Baxi
Brooks House
Coventry Road
Warwick CV34 4LL
MADE
IN
BRITAIN
This brochure is printed on paper sourced from well managed forests and other controlled
sources. This brochure is printed using vegetable based inks. Please recycle this brochure
when you have finished with it.
Baxi policy is one of continual improvement and development. The right to change
specification and appearance without prior notice is reserved. The reproduction of colours
is as accurate as photographic and printing processes allow. The consumer’s statutory
rights are not affected. e&oe
HEARange/July14