.c om Tech n i cal Data Westin ghouse Electric Corporation Distribution a nd Control B u si n ess U n it E l ectrical Components Division Pittsb u rg h , Pen n sylva n i a , U . S . A. 1 5220 29-220 Pag e 1 AB DE-ION® Circuit Breakers for Naval Shipboard Use 5 to 1 600 Am peres 1 500 to 1 50,000 Am peres I. C. lP ar tM an ua ls April 1 99 1 S u persedes Tec h n ical D a t a 29-220, pages 1 -2, dated Feb r u a r y 1 988 M a i l e d to: E, C/29-200A d ca Selector Guide for Navy Circuit Breakers Breaker Type ww w .E lec tri ALB-1 Specification MIL-C- 17588 I Hi-Shock Spec MIL·S-901 I Voltage Rating No. 1 of Inter· rupt1ng Ratmg, Amperes Poles 1 2,500CD 5,000CD 50 NLB-1 MIL-C-17588 MIL-S-901 AQB-A50 MIL-C-17361 MIL-S-901 3 10- 50 NQB-A50 MI L-C-17361 MIL-S-901 3 10- 50 AQB-A100 MIL-C-17361 MI L-S-901 2, 3 15- 100 NQB-A100 MIL-C-17361 MIL-S-901 2, 3 100 AQB-A101 MI L-C-17361 MIL-S-901 3 15- 100 100 NQB-A101 MIL-C-17361 MIL-S-901 3 AQB-A250 MI L-C-17361 MI L-S-901 2, 3 125- 250 NQB-A250 MIL-C-17361 MIL-S-901 2, 3 250 L 1 Tnppmg Elements I 1 Page � Ther Magnetic V De V Ac V De V Ac V De V Ac 2.500 5,000 2,500 5,000 Thermal Magnetic None 11 250 V De 500 V Ac 10,000 15,000 Thermal Magnetic 17 None 17 21 125 125 250 500 250 500 None 5 11 250 500 250 500 V Ac V De V De V Ac 10,000 15,000 Thermal Magnetic 250 500 250 500 V De V Ac V De V Ac None 21 15,000 20,000 Thermal Magnetic 29 None 29 250 V De 500 V Ac AQB-L400 MIL-C- 17361 MIL-S-901 3 250- 400 500 V Ac 150,000 Thermal Magnetic Fuses Thermal Magnetic Fuses Electrical AQB-LL400 MIL-C-17361 MIL-S-901 3 250- 400 500 V Ac 100,000 Electrical 41 AQB-A1601 MI L-C-17361 MIL-S-901 3 500-1600 500 V Ac 75,000 55 NQB-A1601 MIL-C-17361 MIL-S-901 3 1600 500 V Ac Thermal Magnetic None AQB-LF100 MIL-C-17361 MIL-S-901 3 15- 100 500 V Ac 100,000 AQB-LF250 MI L-C-17361 MIL-S-901 3 125- 250 500 V Ac 100,000 CD A 5 ampere breaker has an interrupting rating of 1500 amperes Ac or De. 35 37 41 55 .c om Tech nical Data 29-220 Page 2 ua ls D es c r i p t i o n These molded case Navy circuit breakers provide both overload protection for con ductors a nd short circuit protecti o n for a l l circuit elements such a s conductors, motors and starters. They also serve as m a n u a l dis con necting means as well as circuit pro tectors. All Westing house c i rcuit breakers in this Technical Data meet a pplicable N avy spec ifications fo r "hi-sh ock". These m a n u a l l y operated breakers a re rated f r o m 5 to 1 600 a m peres with interrupting ratings from 1 ,500 to 1 50,000 a m peres. ( See "selector g u i de" on p a g e o n e f o r r a t i n g s a n d N a v y specifications.) an Operating Handle Shown In --,;...,;-�!--- Off Position tM Desi g n Features Westing house Navy circ u i t breakers retain all the features of sta ndard comm erc i a l type A B De- ion breakers listed on the next page under "standard features." B u ilt to Navy specifications, they i ncorporate the follow ing Navy requirements: Spe c i f i c N a vy F e a t u r e s Front view of assembled AOB-A250 Navy circuit breaker. Note that the shock resistant material (MAI-60) used for housing and cover is light gray. ar R e s i s t a n t Mo l d e d C a se: Housing consists of rear base section a n d cover m o l ded of glass a l kyd mate r i a l . This material, reinforced g l a s s f i l led therm oset t i n g p l a st i c , h a s v e r y h i g h m e c h a n i c a l strength ( shock a n d i m pact resistance), i s both f i r e a n d m o istu re-resistant and pro vides exce l l ent d i e l ectric cha racteristics. lP G) Sh o c k @ A n t i -Sh o c k ------- Terminal Studs ca D e vi c e: I nertia weight over center pole holds trip bar i n latched position u n der shock conditions but does not prevent thermal or magnetic trip u n its from fu ncti o n i n g on overload and short circu its. Block ,----- Mounting Mounting Studs Q) C a l i b rated fo r 50'C: All tri Navy break ers are c a l i brated for shi pboard i n stall ation at 50'C a m bient. @) Inte r c h a n g e a ble Tr i p U n it s : All ther ,----- Terminal Mounting Block @ Plug -in lec m a l and magnetic trip u n its i n AQB circuit breakers are encased i n sealed, self-con tained u n its that are i nterchangeable with other trip u n its of d ifferent ampere rati ngs within the same frame size.CD .E C o n n ec t o rs: All AQB break ers are desig ned for easy plug - i n i nstal l a tion. P l u g - i n type connectors a r e built i nto the base of the breaker for use with molded mounting blocks complete with studs. For front connection, pressure-type cable ter minals are used i n stead of plu g - i n con nectors.@ ALB breakers have a clamp ter minal on the l i n e end to receive panelboard bus stab projections. I nterchangeable trip units are n o t available in the A 1 01, ALB-1 or A50. All A101 and A50 breakers have plug-in connectors. Front or rear connectors determined by mounting base selected. w CD ww ® ,---- Plug-In Studs L---- Slip Type Connectors Rear view of breaker showing terminal blocks for switchboard mounting. (Term inal block attached at line end of breaker and remo ved from load end.) Westing house E l ectric Corporation Distribution and Control Busi ness U n it E l ectrical Components Division Pittsburgh, Pennsylva n i a , U . S .A. 1 5220 April 1 991 .c om Westinghouse Electr ic Cor por ation D i stribution and Control Busi ness U n it E l ectrical Compone nts Division Pittsbu rg h , Pennsylva n i a , U . S.A. 1 5220 Standar d Featur es G) Corr osi o n - R es i stant: @ Positive Posi t i o n I n d icati o n : Posi tion of handle always ind icates ON, O F F, or T R I PPED. Bear i n g S ur faces: Dissi milar metals are used to ·prevent bearing wear and elimi nate sticking. ca lP ar @ De-ion A l l o y Co ntacts: Speci a l silver alloy contacts prevent sticking a n d weld i n g , i ncrease contact l i f e and i nsure l o w resis tance when carrying f u l l - rated load. @ Quick- M ake, Arc Chute Removed tri Q u i c k - Br e a k O v er Center Tog g l e M ec h a n i s m : Provides quick, positive action in opening and c l os ing of c i rc u its, prevents "teasi ng" of con tacts and reduces contact wear. AB DE-ION® Circuit Breakers for Naval Shipboard Use tM @ Fr ee @ S i lver Pa ge 3 an All parts are specially treated to resist corrosion. Fung us moisture resistant treatments for severe at mospheres are available as modifications. Ar c Quencher s: This West ingho use development consists of a series of grid plates mounted in para llel between supports of i nsu lating materia l . The slots i n the steel plates are directly over t h e contacts and draw the arc from the movi ng contact u p i nto the divided chamber where it is con fined, divided, and extingu ished. 29-220 ua ls 5 to 1 600 Am peres 1 500 to 1 50,000 Am peres I . C. April 1 99 1 Supersedes Tech n i cal D a t a 29-220, pages 1 -2, dated October 1 978 Mailed to : E, C/29-220A Technical Data (j) C o m pl ete l nter po l e B arr i er s: I nsure interna l @ Common flas hovers when fau lts lec aga inst occur. Tr i p: Two and three-pole u n its have i nsulated common trip bar that opens all poles simu ltaneously when a n overload occurs on a ny one, t h u s eliminat ing possibility of single- phasing. .E ® Tested Accur acy: A l l tripping mem bers have g ro u n d a nd po l i shed latch s u r faces heat treated to prevent g a l l i n g or later distortion. A l l pa rts a re tested i n tempera tu re-control l ed atmosphere to assu re cor rect ca l i bration and p e rfect mati n g . Each breaker is thoro u g h l y tested. w @ Factory ww Sealed: Smal ler breakers are factory sealed to prevent tampering with cal ibration. I ntercha ngeable trip u n its are individ ually sealed. �-- Molded Operating Handle Removed .c om Technical Data 29-220 Page 4 G en eral O r d e r i n g I n fo rmatio n When ordering Westing house N avy circuit breakers, consult the check list below t o m a ke sure y o u have provided correct infor mation. You should specify: ua ls Appl icatio n Designed primarily for circuit protection, Westi ng house N avy circuit breakers are used in l ig hting and power panels, switchboards, distribution centers and load centers aboard ship. The photograph below i l l ustrates the use of molded case circuit breakers i n a typical Navy switchboard. 1 . Quantity, Westi n g ho use Pa rt N u m b e r a n d N ational Stock N u m be r of: a. Com plete breaker or frame, trip u n it, fuses (where required) and/or attachments where ava i l able. b. Pl u g - i n mounting block or front con necting cable term inals. an c . Spare breakers or trip units. (usua lly one required for each ten u n its or fraction there of of each current rati n g . ) d . Technical M a n u a ls. tM 2 . S h i pment: S pecify transportation means, method of packaging and preservation, and required shipping date. 4. I nspectio n : I n d i ca t e w h e t h e r G o v e r n m e n t S o u r c e i nspection i s requ i red at factory p r i o r to shi pment .E lec tri ca lP ar 3 . Drawings: Specify quantity of outline or master plan drawings required. ww w Westinghouse E l ectric Corporation Distribution and Control B u s i ness U n it E l ectrical Compone nts Division Pittsburgh, Pen nsylva nia, U,S.A. 1 5220 April 1 991 """'' .c om Westin ghouse Electric Corporation Distribution a n d Control B u s i n ess Unit E l ectrica l Com ponents D ivision Pittsburgh, Pennsylva n i a , U . S .A. 1 5220 Technic a l Data 29-220 Page 5 Types ALB- 1 , N LB- 1 , 1 2 5 Volts Ac a n d De, 50 Am peres M a x i m u m , 5000 Am peres I. C. ALB-1 an d NLB-1 Breaker s Specification: MIL-C-17588 5-50 Am peres, 60 or 400 Cyc l e 1 2 5 Volts Ac or De S i ng l e Pole List Prices Refer to Price List 29-020 Circuit Breakers- Net Weight: 8 oz. Ampere - _l'l<J!ir1[_ 5 10 15 20 25 30 35 40 50 50 Type tM ar breaker. Note clamp type stab terminal for panelboard mount ing at line end and pressure type termi nal for front con nee· tion at load end. Moun tin g Bases Type ca In terruptin g Ratin g 1 0-50 Amp U n its : 5,000 Amps Ac a n d 2500 Amps De 5 Am p U n it: 1 , 500 Amps Ac o r Dc Single breaker, front panel supported Single breaker, surface mounted Two breakers, front panel supported De, single phase0 and part (%) of combination for 3-phase@ Part (213) of combination for 3-phase application@ 3-phase panel application@) De, single phase0 and part (VJ) of combination for 3-phase@ lec tri H i g h s h ock N avy ALB-1 c i rc u it brea kers are designed for s h i pboa rd protection of s i n g l e phase Ac a n d D e c i rcu its o r th ree- phase Ac c i rc u its when breakers a re c o n n ected by h a n d l e yokes fo r 2 a n d 3-po l e operat i o n . T h e N L B- 1 breaker is the non-automatic de sign of the ALB- 1 . S i nc e the tripping ele ment is om itted, it is used as a m a n u a l disc o n n ect. .E N o n-adjustable thermal and magnetic trip elem ents a re factory c a l i brated a n d sealed. The tripping element i s counterba l a nced to reduce possi b i lity of acc identa I tripping u n der shock. All parts a re given a c o rrosion resistant treatment i n c o m p l i a nce with M I L- E-91 7 . ww w P l u g- i n l i n e c o n nections s i m p l ify panel board mounting. A c l a m p type term i n a l o n the l i n e end of the breaker provides plug- i n c o n n ec tion to bus stabs in panel boa rd m o u nting bloc ks . F o r front connection, there is a p res s u re type te r m i n a l o n the load end of the breaker. National Stock No. 5925-00-204-7494 5925-00-204-7488 5925-00-549-5366 5925-0 1 -01 7-301 1 5925-00-549-5359 5925-00-549-5360 5925-01 - 1 7 5-8204 5925-01 -261 -5625 5925-00-549-5365 5930-00-548-7068 Special ALB-1 an d NLB- 1 Breakers S i m i l a r to a bove exc e pt to have a 1 A-1 B a u xi l i a ry switch rated 5 a m p resistive, 250 volts Ac o r 30 volts De max. ( N ot s u b m itted for Navy a p p rova l . and does not use brea ke r m o u nt i ng bases. ) O rder by desc ription. lP ALB-1 Navy circuit Style Number -454i5567G01 454D507G02 454D507G03 454D507G04 454D507G05 454D507G06 454D507G07 454D507G08 454D507G09 454D507G1 0 an ALB-1 ALB-1 ALB- 1 ALB-1 ALB-1 ALB-1 ALB- 1 ALB-1 ALB-1 N LB-1 CD AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls April 1 99 1 Supersedes Tec h n ic a l D a t a 29-220, pages 5-6, dated May 1 980 M a i led to : E, C/29-200A Top view of typical ALB-1 panelboard mount ing base. (Style 4540509G04) National Stock No. 5925-01 -005-4983 Style Number 454D509G01 454D509G02 454D509G03 454D509G04 5925-00-660-3562 454D509G05 5925-00-201 -7 1 75 454D509G06 5925-00-544-5980 5925-00-20 1 -7 1 76 454D509G08 . .......... . .... .. .... . . Net Wt. in Lbs. '!. '!. '/, 'h 2/ 3 'h In dividual Reproduction s: When req u i red, reproductions of m a ster d rawings, outl i n e draw i n gs and certific ation sheets can be ordered as f o l l ows: Item 1 2 3 4 [)_escription Full size photolithic tracing of master drawing on vellum Outline and drilling plan on vellum Certification data on vellum Reproductions of items 1, 2 or 3 Drawin gs Available : Master drawing 900J396; breaker outl i n e 3 1 4C 2 1 8; m o u nting bases 455D791 a n d 369D592. Techn ical Man u al: N avships No. 362-2228. This booklet per M I L- M- 1 5071. When re q u i red, o rder BVR-TM-378. Han d le Y okes: Provide i nter l ocking of two or th ree one-pol e brea kers for s i m u ltaneous oper ation. I n di v i d u a l pole tripping is o bta i n e d without n o r m a l trip i n dicating (center) position. Poles 2 3 CD @ Style N-- umber 207B508H01 207B508H02 -- ------ Tr1pp1ng element omitted for manual disconnect. Letter "N" hot stamped in white on handle. In De or single phase panel applications, basic patter� IS one molded base accommodating four single-pole break ers. (See pages 7 and 8.) @ National Stock No. 5925-00-202-0938 5925-00-296-8926 In 3-phase application where bas1c pattern is three molded bases, one 454D509G04 and two 454D509G05 are required, each base accommodating two breakers per cir @ cuit {See page 7.) For 3-phase application where basic pattern is one molded base accommodating up to six breakers or two breakers per circuit (See pages 8 and 9.) .c om Technical Data 29-220 Page 6 Outline Dimensions ALB-1 Breaker and M o u nting Bases Br eaker Outline ua ls Single Base, Fr ont P anel Suppor ted (454D509G0 1 ) )0 Tr 1 pped ? 32 1�f-� 32 32 322 2. 16 _J ___!:_ 16 22 rl@ ii Mounting slot Ampere Rot1ng � � _1______1, 2-J- Standar d Br eaker l ca .190-32 Top I 2 holes) 16 12_1 ----<;�l 5 I 41r 32 ___, z '-I l____t_ -=-� • . Steel plate . -- 5 54 thiCk --:!' - -� 'tof 1 _.j Mount1ng plate Mounting of Fr ont P anel Suppor ted Bases (Side View) 2-.190-32 X 3 Breaker escutcheon and mountmg s crews Base mounting screws 7 �32 32 lec Crit1col dimens1ons of stab and mount1ng clip 3 / � / with tri 1515 3 f1 32 !1-:'_ttf $14 ffi� JT 'r-�tf tf��.:'" 2 Screws, steel, .190-32 X 3 furnished lockwoshers for secunng to panel front cover zl Special Br eaker with Auxiliar y Switch Single Base Surface Mou nted (4540 509G02) -��3264� tM Ampere rot1ng I I ar l_ Two Br eaker Base, Fr ont P a nel Suppor ted (454D509G03) lP I� 8 an �a- 3 P ole Handle Yoke (207B508H02) �-�u:J-- --o =t_J] 15 .195 �--��- 2 32- .23 4 � n 2 P ole Handle Yoke (207B508H0 1 ) ww w .E Mounting of Surface Mounted Base (Side View) Westinghouse E l ectric Corporation Distribution and Control Busi ness U n it E l ectrical Compone nts Division Pitts b u rgh, Pennsylv a n i a , U . S.A. 1 5220 Apr il 1 991 .c om Tech n ic a l Data Westinghouse Electric Corporation Distribution a n d Control Busi ness U n it Electric a l Components Division Pittsburg h , Pennsylv a n i a , U . S . A. 1 5220 April 1 99 1 Supersedes Technic a l D a t a 29-220, pages 7-8, dated October 1 978 M a i led to: E, C/29-200A AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls ABL-1 Breaker Mounting Bases, Continued Bus Bar Drilling for De and 1 Phase Panels (Y. x 1 Copper Bus not Supplied) (2 Separate Bases shown. Basic Pattern i s 1 Molded Base Acc om modatin g 4 Single Pole Breakers) Busbor C an Stab Bose Page 7 Types A LB - 1 , N L B - 1 , 1 25 Volts Ac and De, 5 0 Amperes Maximum, 5000 Amperes I . C. Application in De and 1 Phase Panels Busbor A B usoor A ar tM BusborC 29-220 Front Vrew Phase Panel Application lP 3 For Two Breakers per load Circuit (Basic Pattern of Three Separate Moulded Bases can be R epeated for Longer Panel Boards) Bu s bar A ca Bus barB and stab base Bus Bar Drilling for 3 Phase Panels For Two Breakers per Load Circuit (Y. x 1 Copper Bus not Supplied) 4540509G05 7 ib Front View ±�1 t tri Stab base mtg screws / .190 · 32 Topped w .E lec Stab bose mtg Outline Dimensions for Mounting Bases 454D50 9 G 04 or 454D509 G 05 ,�H01ameter 2 counter bores �dee� ww 13 �--�t 1�2 • �j-- - --64 D1ameter �4-�-------------�, _cZ�h�o�el �s-----� 16..3 . iL------6* 7 -�--=il- Front Vrew holes Technical Data .c om 29-220 Page 8 Dimensions, Continued ALB-1 Breaker and Mounting Bases Application in De and 1 Phase Panels (2 Separate Ba ses shown. Basic Pattern is 1 Molded Base Accommodating 4 Single Pole B reakers) (� x 1 Copper B u s not S u pplied) 35 BusbarC "- � Bus bar A....._ � ua ls " � Bus bar A Bus Bar Drilling for De and 1 Phase Panels 4540509G08 64 II 316 _ / 4540509G08 Stab base and mounting 2 � 2 an .190-32 L Tapped holes tM 4540509G08 3 Phase Panel Application For Two Breakers per load Circuit ( B asic Pattern of Three Separate Molded Bases can be Repeated for longer P a nel B oards) � ar Bus bar B and Stab base 4540 509G05 B usbar �/ 1 32 �� ____<1..-- Phase Panels L ca 1 32 3 For Two Breakers per Load Circuit (� x 1 Copper Bus not S u pplied) � "454D509G05 tri � -- 454 D509G05 c i:n � .E lec � Stab base an d lP Busbar C Stab base and mounting screw �/ � Bus Bar Drilling for hick steel 6 T .190-32Thd. Side View Outline Dimensions for Mounting Bases (Side View) 454D509G05or 454D509G08 ww w p� ' ,_ v �- - -' 1 Outline Dimensions for Mounting Bases 454D509G05 or 454D509G08 R Dia. 2 holes April 1 991 .c om 8 Tech nical Data Westingh ouse Electric Corporation Distribution a n d Control B u s i n ess Unit Electrica l Components Division Pittsburgh, Pen nsylva n i a , U . S .A . 1 5220 A LB - 1 , N L B - 1 , 1 25 Volts Ac, De; 50 A mperes Maximum, 5000 Amperes I . C. Apri l 1 99 1 S u persedes Tech n i c a l D a t a 29-220, pages 9- 1 0, dated October 1 978 M ai l ed to: E, C/29-200A Page 9 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Types 29-220 ALB-1 Breaker Mounting Bases B u s Bar D r i l l i n g fo r 3 P h ase P a nel A p p l icatio n (For One or Three Breakers per Load Circuit) For One or Three Breakers per Load Circuit (Y. x 1 Copper Bus not Supplied) tM an 3 P hase P a nel Applicatio n ar Stab base and mtg. scews lP I I I -� ca 454D509G06 O u t l i n e D i mensio ns fo r Mo u nting Base 454D509G06 2� 32 � 31 tl 64 7 3, oiameter 2holes v: "" 3 -- a tri r 6� � Dia meter 2 counter bores/ � deep lec --r. 3 8 I 2 I 4 Front P a nel Cutout 1� Diam eter megg er holes if required .E O ut l i n e o f Base ( S i d e View) 454D509G04, 454D509G05, 454D509G06, 454D509G08 Fro n t Vi ew w Han dle p ivot ww 5 -+---3i6 For 1 three pole circuit For 1 Single pol e c ircuit .c om Technical Data 29-220 Page 1 0 Time� Current Curve 2 I 40 20 f---1Characteristic Time Current Curve f---1Instantaneous Tripping Occurs 320 Amperes or 20 T 1mes Element Rating f---1Whichever is Less ..... More Than 050 Sec 800 Amperes Less Than .200Seconds \ 0 \ 2 \ I==I= \ 0 " "' � 0 � ' 0 in 0 0 .., 4 "' 6 4 0 u I a. ;E E ;= ...... f\. Minimum/ / ...... ' 2 ""' 2 I 4 Times Rated Current 5 6 7 8 9 10 20 C h a ract er i st i c Tempe rat u r e R at i ng C u rv e 110 105 95 90 85 75 70 / 100 ./ 90 / eo v 10 v v / / / � + Load Type ALB-1 lec 10 0 v 50 Ambient Temperature, °C so 40 30 20 10 90 100 200 300 500 l/ Connection a � Line 1 Dr w Out Stationary �/ C onn e c t1o n Load Type NLB-1 o .E Go 70 tri II5 30 """' Line 120 J .... Wiring D i ag ra m 125 80 ""' I' I 2 Maximum tM "' � I 0 ar '\. 2 u '"' u an \\ I 0 lP l Characteristic 4 ca � MI L-C-1 7588 This specification i ncludes the A L B - 1 type circuit breaker. It req u i res that this breaker carry 1 1 5% of c u rrent ratings for more than one hour and that the pri mary elements i n i tiate tripping at 1 38% rated c u rrent with i n o n e h o u r a n d a t 200% i n 1 0 t o 1 00 seconds. A tripping c haracteristic of the primary element is based on the cu rrent flowing through all poles in series and in a n ambient of 50"C. The minimum i nstantaneous trip setting shall be 320 amperes or 2 0 times the element rati ng, whichever i s less, and tri p at not less than .050 second. At 800 a m peres t h e breaker must trip a t .200 second or less. ua ls { C h a ract erist i c C u rves A L B - 1 Breaker Cha ract er i st ic T i m e - C u r re nt C u rve ww w West i n g h ouse E l ectric Corporation Distribution a n d Control B u si n ess U n it E l ectrical Com ponents Division Pittsburgh, Penn sy lvania, U . S .A. 1 5220 April 1 991 West ingh ouse Elect ric Corporat ion Distribution a n d Control Busi ness U n i t E l ectric a l Components Division Pittsbu rg h , Pen nsylva n i a , U. S .A. 1 5220 29-220 Page 1 1 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls AOB-A50, N OB-A50, 500 V Ac, 250 V De 50 Amperes M a x i m u m , 5000 Am peres Ac, 2500 Am peres De \ . C. .c om April 1 99 1 N e w I nformation M a i led to: E, C/29-200A Tec h n ic a l Data AOB-A50 and NQB-A50 Breakers an Specificat ion: MI L-C- 17361 1 0-50 Amperes, 60 and 400 Cyc l e 500 Volts Ac and 250 Volts De 3 Pole tM I nt errupt ing Rat ing 5000 Amperes Ac and 2500 Am peres De Non-I nterc h a ngeable trip u n it Class H i -S h oc k M I L-S-90 1 , 50° C a m bient lP ca The N O B -A50 b r e a k e r i s a n o n- a u t o m a t ic design of the AOB-A50. S i nce the tripping e l e ments a re o m itted, it is used as a m a n u a l dis c o n n ect. T h e N O B -A50 h a s a m a x i m u m conti nuous c u rrent rating of 50 a m peres. ar The AOB-A50 is a factory c a l i brated non adjusta ble thermal m a g n etic c i rcuit breaker. The c i rcuit breaker i s assembled as a th ree pole device with c i rc u it protecting trip ele ments i n the two outside pol es. The unit c a n b e i n sta l l ed i n 2 p o l e a p p l ications b y con necting the 2 w i re c i rcuit to the outside pro tected poles. List P rice See Price List 29-020 T rip Un it Rating St y le Number National Stock Number 60 Cycle AQB-A50 AQB-A50 AQB-A50 AQB-A50 AQB-A50 AQB-A50 AGB-A50 AQB-A50 10 15 20 25 30 35 40 50 1244C52G01 1244C52G02 1244C52G03 1244C52G04 1244C52G05 1244C52G06 1244C52G07 1244C52G08 5925-00-783-6399 5925-00-797-9692 5925-00-799-5669 5925-00-797-9693 5925-00-391-0914 5925-00-797-9695 5925-00-783-6635 5925-00-797-9696 400 Cycles AQB-A50 AQB-A50 AQB-A50 AQB-A50 AQB-A50 AQB-A50 AGB-A50 AGB-A50 10H 15H 20H 25H 30H 35H 40H 50H 1244C52G09 1244C52G10 1244C52G 1 1 1244C52G 12 1244C52G13 1244C52G14 1244C52G15 1244C52G16 5925-00-783-6398 5925-00-799-8871 5925-01-025-7001 5925-00-797-9701 5925-00-199-9518 5925-00-817-6294 5925-00-817-7860 5925-00-817-7861 NGB-A50 Non-Automatic 1244C52G25 5925-00-948-3296 ww w .E lec tri Type Gl ® Refer to Westinghouse for De Part Numbers and Information. Q) Complete breaker does not include mounting bases. Type requi red must be ordered separately. Mounting bases include cable lugs. 0 Only pole breakers furnished; for 2 pole application make connections to outside poles. 3 Tech nical Data .c om 29-220 Page 1 2 Style Number National Stock Number Single Base- Line and Load Stabs, Front Connected Single Base- Line and Load Stabs, Rear Connected Single Base- Line Rear, Load Front Connected Double Base Assembly- Line, Bus Connected; Load, Front Connected Handle Lock Handle Boot Technical Manual 1244C44G01 1244C44G02 1244C44G03 1244C45G0 1 5080A95H0 1 752B729H01 1244C59H01 5925-00-270-4004 5925-00-270-4005 5925-00-270-4006 5925-01-246-0569 5925-01-09 1 -9432 Net Weigh t - Lbs. AOB-A50- 2.2 N OB-A50- 1 . 9 an S i n g l e Mounting Base- 0.7 Double M o u nting Base- 1 . 5 Handle Lock- .03 ua ls Panelboard Mounting and Accessories Type AQB-A50 Single Mounting Base- Rear Connected Single Base Line Stabs Rear Connected; Load Stabs Front Connected .E lec tri ca lP AQB-A50 Single Mounting Base - Front Connected ar tM Ordering Information : See Page 4 Handle Lock Double Mounting Base- Front Connected ww w Westi nghouse E l ectric Corporation Distribution a n d Control Busi ness U nit E l ectrical Components Division Pittsburgh, Pennsylva n i a , U . S .A . 1 5220 April 1 991 Apr i l 1 99 1 N e w Information Mai led to : E , C/29-200A Outline Dimensions AOB- A50 a n d NOB-A50 Breakers (Dimensions in I nches) INSERTS IN COVER (21 •12-24 THDS 3 3 8 8 ""","" """'" 1 I � lP ca tri ' ---- 'R I I I I 1'13? [ OF CLIP } 2 2 j rr= r;=:=J !i 4; 2 85 OFCLIP LOAD END I LINE LINE _, 2.6 .E I I I I F It ;1 Side View 1; lec 55 AB DE-ION® Circuit Breakers for Naval Shipboard Use 11 1 111 1 1 1 - OFF Front View Page 1 3 ; tM 3 ar 4 29-220 an BREAKER MOUNTING HOLES TWO #12-24 MOUNTiNG SCREWS 4 1/8 LONG SUPPLIED WITH BREAKER Technical Data ua ls AQB-A50, N QB-A50, 500 V Ac, 250 V De 50 Am peres M a x i m u m , 5000 Am peres Ac, 2500 Am peres De I . C . .c om Westingh ouse Electric Corporation Distribution and Control Busi ness Unit E l ectrical Compon ents Division Pittsbu rgh, Pennsylva nia, U .S .A. 1 5220 LOAD LOAD TYPE AQB-A50 TYPE NQB-A50 ww w Wiring Diagram 5 ,, DIA FOR INSULATION TEST Front Panel Cutout .c om Technical Data 29-220 Page 1 4 ua ls Single Base Un its (Dimensions i n I nches) tM an 29 64 line and Load Stabs Back Connected ca lP line and Load Stabs Front Connected WIRE CONNECTION ar WIRE CONNECTION .E lec tri 10-32 THDS. WIRE CONNECTION line Stabs Back Connected, Load Stabs Front Connected ww w Westing house E l ectric Corporation Distribution a n d Contro l Busi ness U n it E l ectrical Components Division Pittsburgh, Pennsylva nia, U . S.A. 1 5220 April 1 99 1 .c om Westingh ouse Electric Corporation Distribution a n d Control B u s i n ess Unit E l ectrical Compon ents Division Pittsburgh, Pennsylva n i a , U . S.A. 1 5220 29-220 Page 1 5 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls AQB-A50, N QB-A50, 500 V Ac, 250 V De 50 Amperes Maxim u m , 5000 Am peres Ac, 2500 Am peres De I .C. April 1 99 1 N e w Information Mai led to : E, C/29-200A Technical Data 't OF CIRCUIT BREAKERS LOAD tM LINE an Double Base Assembly (Panelboard) (Dimensions in I nch es) 1 2 lP ar 2,;; 16 LINE ww w .E lec tri ca I 32 r----- 1"" L_____j_ __ Line Bus Connected, Load Front Connected #10-32 THREAD Technical Data .c om 29-220 Page 1 6 Navy Type AQB-A50 Circuit Breaker 0 0 N ;: \ 1000 500 300 200 r.n 0 z 0 u w r.n � w :; 50 30 20 N g '" oo oo oo "" "' 0 0 0 2 g 0 N 0 oo 0 oo 0 oo 0 oo "" "' '" 0 0 0 0 0 10000 5000 � -0 3000 � 2000 :I g � (/) 500 300 200 \ 1\ \ \ ' 10 0 g 1000 I 100 g 0 0 0 an 5000 3000 2000 o- 0 00 00 _, "' 1\ )..--- \ i= 100 tM <r " 0 0 50 30 20 Maximum Trip Time 10 ar 10000 0 "' ua ls PERCENT RATED CURRENT '\. lP \ ca v ' Minimum Trip Time tri 0 05 003 0.02 01 .3 1\ 1\ 0 05 0 03 0.02 I\ lec .E 0 "' 0 2 0 0 N 0 00 00 "" g "' 0 0 0 :;· '" c. :;· c "' 01 )> 005 003 002 005 003 002 001 4' 0 0 0 N 0 00 0 0 '" .q- 1..1) gg 0 0 0 2 PERCENT RATED CURRENT 0 0 0 0 N 0 oo 0 oo 0 oo 0 C) ciO "" "' 0 0 0 001 0 0 Time-Current Curves for AOB-A50 Circuit Breaker (60Hz, 400Hz and dc-10, 1 5, 20, 25, 30, 35, 40 and 50 Ampere Ratings) ww w Westing house E l ectric Corpo ration Distribution and Control Bu siness U n i t E l ectrical Compon ents Division Pittsburgh, Pennsylva nia, U . S .A. 1 5220 April 1 991 I nterr u pti n g R at i n g 1 5,000 Amps A c a n d 1 0,000 Amps De ua ls Those breakers (and i nterrupte rs) desi g n ed for De motor ci rcuits a n d fo r Ac feeder c i r cuits (designated with a "BF" in a m p rat i n g co l u m n of price table) h a v e fixed i n stanta neous settings of 600%-700% cont i n u o u s cu rrent ratings. Those h a v i n g a mag netic e l em e nt set to trip at 1 200%-1 400% a re applied on Ac moto r ci rcuits (designated with a "B"). Breakers desi g n ated with "BE" are calib rated for De appl icati o n . List P rices See Price List 29-020 ' 1 764 1764 1764 1 764 1 764 1 764 1 764 1 764 681 682 683 684 685 686 687 688 1 05 175 350 525 700 1 764 1 764 1764 1764 1 764 90 1 05 1 80 210 1 50 175 300 350 300 350 600 700 450 525 900 1 050 600 700 1 200 1 400 Non-Auto matic 1 764 1 764 1 764 1 764 1764 1 764 1 764 1 764 1 764 1 764 1 764 1 05 175 350 525 700 Two-Pole, 500 Volts Ac Three-Pole, 250 Volts 90 1 50 300 450 600 De .E 1 5-BE 25-BE 50-BE 75-BE 1 00-BE Three-Pole, 500 Volts Ac ww w 1 5-BF 1 5-B 25-BF 25-B 50-BF 50-B 75-BF 75-B 1 00-BF 1 00-B 1 00® . . . . . . . 638 638 638 638 638 . . . . . ......... ... 5925-00-396-2283 . ...... . .. .. . . .. ......... . ..... .... .... . .. . .. . . .... .. . ... .. . .. .. . .. . . .. . . .. .. . 1764 1764 1 764 1 764 1 764 1 764 1 764 1 764 638 638 638 638 638 638 638 638 . .. .. .. .. .... ..... . .. .. . .. . . . .... 689 690 691 692 693 .............. 5925-00-399-81 20 ....... ....... ..... ......... 5925-00-399-81 27 1764 1 764 1 764 1 764 1 764 694 695 696 697 698 699 700 701 702 703 704 5925-00-1 1 3-5066 . .. .. . .. ... ... 5925-00-658-9609 5925-00-265-9474 5925-00-988-5474 5925-00-396-2339 .. . . . .. . .. .. . 5925-00-396-2345 . . .. . ..... .. . 5925-00-450-6275 5930-00-259-9440 1 764 1764 1764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1764 . .. .. . ... . . . 5925-0 1 -221-1 765 ... ........... . . .. ........ ........... . .. . . . . . . . . . . . ' . . . . ' ' . . . . . . . . . . Trip Unit Only Style National Number Stock No. . . .. . .. . .... .......... .. .......... .. .... ....... 1 764 1 764 1 764 1 764 1 764 lec 90 1 05 1 80 210 1 50 175 300 350 600 700 900 1 050 1 200 1 400 Non-Automatic 1 764 1 764 1 764 1 764 1 764 Breaker Frame OnlyCD National Style Number Stock No. ca De 676 677 678 679 680 90 1 50 300 450 600 1 5-BF 1 5-B 25-BF 25-B 50-B 75-B 1 00-B 1 00® Co m plete Breaker(]) National Style Stock No. Number tri 1 5-BE 25-BE 50-BE 75-BE 1 00-BE AOB-A100 lP AQB -A 1 00 circuit breakers are designed for use in lighting and distribution panel boards and switchboards for the protection of feed er and motor branch circuits. Trip u n its with cu rrent rati ngs of 1 5, 25, 50, 75 and 1 00 can be q u i ckly i nterc hanged and a conversion kit is available to change a 3 - pole, 500 volt AQB-A 1 00 to a non automatic N Q B - A1 00 circuit i nterrupter. N Q B - A 1 00 breakers have a maximum con tinuous current rati n g of 1 00 amperes, but they are used only as disconnects si nce there is no a u tomatic opening device. an Specificat i o n : MI L-C-17361 1 5-1 00 Amperes 500 Volts Ac and 250 Volts De Two or Three- Pole AB DE-ION® Circuit Breakers for Naval Shipboard Use tM Note: AQB-A100 and NQB-100 breakers are sold for replacement only . Th ey are no longer on Navy Qualified P roduct List. Two-Pole, 250 Volts Page 17 ar A Q B - A1 00 and N Q B - A 1 00 B reakers I nsta nta neo us Trip Setting in Amperes Low High 29-220 Types AQB-A1 00, N Q B -A1 00, 250 Volts De, 500 Volts Ac, 1 00 Am peres Maximum, 1 5,000 Amperes I . C . April 1 99 1 S u persedes Technical Data 29-220, pages 1 1 -1 2, dated Octo ber 1 978 Mai led to: E , C/29-200A Cont. Ampere Rating .c om 8 Technical Data Westingh ouse Electric Corporation Distribution a n d Control B u s i n ess U n it E l ectrical Com ponents Division Pittsburgh, Pennsylv a n i a , U . S.A. 1 5220 1764 1764 1 764 1 764 1 764 640 641 642 643 644 . . ... .. ... .... . 5925-00-248-1 1 04 ......... ..... 5925-00-248-1 1 08 .. . . ....... . .. 645 646 647 648 649 650 651 652 . . .. .... . . .. . .. .. . . 1 764 1 764 1764 1764 1764 1 764 1 764 1 764 ..... ..... 5925-00-629-0975 ............... 5925-00-628-0695 5925-00-248-1 078 5925-00-248-1 082 .............. 5925-00-772-0646 639 639 639 639 639 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 1 764 1 764 1 764 1 764 1 764 653 654 655 656 657 5925-00-608-0972 5925-00-553-9745 5925-00-383-381 4 5925-00-248- 1 371 5925-00-608-0973 639 639 639 639 639 639 639 639 639 639 639 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 5925-00-258-2945 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 658 659 660 661 662 663 664 665 666 667 668 5925-00-502-671 9 5925-00-248-1 453 5925-00-21 5-3758 5925-00-248-1 449 5925-00-248-1 442 5925-00-248-1 443 5925-00-248-1 436 5925-00-248-1437 5925-00-248-1 429 5925-00-588-2453 5925-00-699-1 1 1 1 . . . . . . . ' . . ........ .. . . . . . ' . . . ' . . . . .. .. .. .. ..... .... ... . . . . . ... . .. .. . . . . . . ... ... ' . . . . ' .. . . . . . . . N ote: Breakers with ratings other than those given on this page are considered special and ful l description data must be provided. Styles listed include slip-type connectors for rear connections. Order front terminal connectors separately if required. No additional charges for front connectors ordered with breakers or frames. ®Type NQB-A100 non-automatic. To convert 3-pole AQB breaker to NQB breaker, order style 1764 668 only. CD .c om Cl Technical Data 29-220 Page 1 8 A Q B - A 1 00 a n d N Q B - A 1 00 B reakers, Continued Prices given below apply only when connectors are ordered separately. When breakers and the req u i red lugs are ordered simu ltaneously, these l u g s will be supplied without charge. N3-N14 N23-N40 N50-N75 I 1 Navy Cable Size, Max.CD 1 4,340 38,91 0 75,780 CD Circular mils area. I I Description One Pressure Connector One Pressure Connector One Pressure Connector I 1 National Stock No. Style N umber Tech n i c a l M a n u a l N avships 362-081 9per MI L- M - 1 5071 : When required, specify I B - 2 9 -0 6 2 - C I A . 1 763 660 1 763 661 1 763 662 tM Switchbo a rd Mo u nt i n g Com plete breakers and frames include mounting hardware. Female slip connectors are mounted in the breaker base for plugging onto stud projecti ons of terminal mounting block assemblies. Order one mounting block assembly for each end of the breaker. Number Poles Description Style N u m ber National Stock No. 2 3 2 or 3 Mounting Mounting Mounting One Stud 1 764 1 764 1 764 1 631 5940-00-643-7 194 5940-00-501-9 120 Complete Breaker 2.75 3.25 1 0.00 8.75 1 0.75 9.50 Trip Unit Item Descr i ption 2 3 4 Full size p h otolithic traci ng of m a ster d rawi ng on ve l l u m Outl i n e a n d d ri l ling p l a n on v e l l u m Certification data on vellum Reprod u ctions of Items 1 , 2, or 3 D rawings Ava i l a b l e : M aster drawing 1 - J F-630; rear connected breaker outline, drilling and wiring diagra m 20- B - 2881 ; front connected breaker outli ne, drilling and wiring diagram 3 0 - B - 3837. 400 Cycle B reakers : Refer to Westing house. 2-Pole AOB- 2.625 2-Pole NOB- 1 .375 3-Pole AOB- 2.875 3-Pole NOB- 1 .625 tri 2-Pole AOB 2-Pole NOB 3-Pole AOB 3-Pole NOB Frame 2-Pole AOB- 7.375 2-Pole NOB- 7.375 3-Pole AOB- 7.875 3-Pole NOB- 7.875 I n divi d u a l Repro d uctio ns : W h e n re quired, reprod uctions of master drawings, outl ine drawings and certification sheets can be ordered as fol l ows: ca 2-Pole Mounting Block Assembly 3-Pole Mounting Block Assembly ar Net Weight, Lbs. Terminal Mo unting Suppo rts (Set of Two ) 675 674 240 442 lP Block Assembly Block Assembly Block Only Assembly- Complete with 4 Nuts F u n g u s - Mo i s t u r e R e s i s t a n t T r e a t ments: (Jan- T- 1 52, J a n - C - 1 7 3 or M I L-V1 73 ) if specified, contact Westing house. External parts are coated; trip u n its are not treated. an Cable Range Additions H a n d l e Lo ck : When specified, order style 1 6 1 4 485. One furnis hed without charge per every 1 0 breakers, when requested. ua ls F ro nt Co n nected B reakers For the load ends of panel board breakers and for other front terminal applications, pressure conn ectors should be ordered. w .E lec s ww West i n g ho u se E l ectric Corpo ration Distribution and Control B u s i n ess Unit Electrical Com ponents Division Pitts burgh, Pennsylvania, U . S . A. 1 5220 April 1 991 April 1 99 1 S u persedes Technica l D a t a 29-220, pages 1 3- 1 4, dated October 1 978 M a i led to: E, C/29-200A Types AQB -A1 00, N Q B -A1 00, 250 Volts De, 500 Volts Ac, 1 00 Am peres Maximum 1 5,000 Amperes I . C . ! Term1nal mtg block 1_ . Lme End ar lP Visable amp rat1ng inlerchangeable tri p unit Drilling Plan Front Cover Cutout ca For Mounting Pa nel (Front View) � D10. megger 8 tri _ 16 1 _!_ Min. -;l 0t ww w .E lec Load End IS fest holes """', om1t m1ddle hole for 2 pole 29-220 Page 1 9 AB DE-ION® Circuit Breakers for Naval Shipboard Use an I tM Thd· Tech nical Data ua ls O u t l i n e D i mensions AQB -A1 00 and N Q B -A1 00 Breakers _18 5 8 .c om 8 Westinghouse Electric Corporation Distribution a n d Contro l B u siness Unit E l ectrica l Compo nents Division Pittsburgh, Pennsylva n i a , U . S.A. 1 5220 098 Dia. hole for handle lock and Mounl1ng bolls and wa s hers �±��"""===-' (furnished lermmal (4) wilh blocks) �-20xl� LG hex hd s bolls Slolled pole current corrymg ports are omilled .c om Tec h n ical Data 29-220 Page 20 C h a racteristic C u rve A Q B - A1 00 B reakers <1) "' ::;;: E f= \ 10 5 3 2 c 0 u Q) (f) -- \ \ f\ 4 i: Instantaneous 0 c Trip at 600% to 700% Rat1ng I \ ii I I I I I � ' \ ·, ' 5 4 3 2 0 0 0 0 N 00 00 r<> " Percent Rated Current \ \ � 10 5 3 2 l\f\ 40 30 20 15 10 ,\ I 50 40 30 20 I 40 30 20 15 10 Maximum M1n1mum 1 V> " 1400% Rating "" :-.... I'� I I 5 3 2 I 0 ' !! II II 0 00 0 0 0 0 00 00 0 w ro o <D O 0 - N r<> O perat i ng Cha racteristics Trip U nit Rating 1 5-1 00 Amperes 50'C Ambient - Cold Start. 60 Ac or D e ua ls :; \ Trip at 1200% to o o 0 o 0 o o Per Cent Rated �rre;; o o <t o o o o o o o..o ro 0 :I I j o o o o � 2 o o � tM 40 30 20 V> <1) \ 1 an ---Instantaneous 3 2 4 3 2 Operating Cha racteristics Trip U n it Rating 1 5- 1 00 Am peres 50'C Ambient - Cold Start 400 Cycle Ac ar :; S pecificatio n MI L-C-1 7361 This specification covers all therma l - ma g netic AQB breakers. It requi res t h a t they carry 1 50% of current rati n gs for at l east one hour and that thermal elem ents initiate tripping at 225% rated current within one hour and at 600% i n 25 seconds p l u s or m i n us 2 5%. The instantaneous magnetic setti ngs for each conti n u ous ratings a re based on intended appl ications. (Thermal tri pping tests are cond ucted with a l l poles in series in 50'C a mbient; each pole is tested individ ually to check magnetic setti ngs.) 400 Cycle B reakers �T 0 0 I Tri p U n i t R a t i n g 90 Cycle, 80 lP V> 0 I 5 4 I l 70 � 60 ca 50 40 30 J tri 20 .E lec 10 0 0 0.5 Factor 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 To determine the tri p unit rating to be used, when the load c u rrent and a m bient are known, m u ltiply the load current by the factor obtained from this curve for the known a m bient. The result will be the ideal trip u n it rating. However, since tri p u n its are furnished only with standard ratings as per N avy spec., select the sta nd a rd trip u n it whose rati ng is equal to or one rating hig her than the ideal rating. ww w Westi n g house E l ectric Corpo ration Distribution a n d Control Busines s U n it Electrical Compo nents Division Pittsburgh, Pennsylva n i a , U . S.A. 1 5220 April 1 99 1 Types AOB-A1 0 1 , N QB - A1 0 1 , 250 Volts De, 500 Volts Ac 1 00 Am peres M ax i m u m, 1 5,000 Am peres I . C . N O B - A1 0 1 circ u it breakers have a maxi m u m conti n u ous current rating of 1 00 a m peres. They a r e used o n l y as discon nects, since they do not i nc l ude an automatic open ing device. � These breakers have adjustable i nstanta n eous trip settings o f "lo", "i ntermediate", List P rices See Price List 29-020 15 Amp 25 Amp 50 Amp 75 Amp 1 00 Amp 1 00G Amp 1 00 Amp 400 Cycle AQB-A101 AQB-A101 AQB-A101 AOB-A 1 0 1 AQB-A101 AQB-A101 1 5 H Amp 25H Amp 50H Amp 75H A m p 1 00H Amp 1 00GH Amp Magnetic Only Style 458D509G 1 1 458D509G 1 2 458D509 G 1 3 458D509G 1 4 458D509G 1 5 458D509G 1 6 458D509G20 5925-00-876-9 2 1 6 5925-00-876-9217 5925-00-876-92 1 8 5925-00-876-9 2 1 9 5925-00-876-9220 5925-00-61 9-0412 5930-00-969-2477 458D51 1 G 1 1 458D5 1 1 G 1 2 458D5 1 1 G 1 3 458D5 1 1 G 1 4 458D51 1 G 1 5 458D 5 1 0G 1 1 458D 5 1 0G 1 2 458D5 1 0G 1 3 458D5 1 0 G 1 4 458D5 1 0G 1 5 458D5 1 0G 1 6 5925-00-867-7328 5925-00-867.7329 5925-00-986-73 1 3 5925-00-986-73 1 4 5925-00-972-3000 458D5 1 2G 1 1 458D5 1 2 G 1 2 458D5 1 2 G 1 3 458D5 1 2 G 1 4 458D5 1 2G 1 5 Thermal Mag netic Style 1 80- 2 1 0 300- 350 600- 700 900-1050 1 200-1 400 1 200-1400 Non-Automatic , 75-105 1 25-175 250-350 375-525 500-700 500-700 tri ca . f A O B -A1 01 National Stock N u m ber nstantaneous Trip Setting @ A c 6 0 Cycle . Hi Lo lP AQB-A101 AOB-A101 AQB-A 1 0 1 AOB-A 101 AOB-A101 AQB-A1 0 1 ® NQB-A101 AB DE-ION® Circuit Breakers for Naval Shipboard Use an AOB-A1 0 1 circuit breakers are designed for use i n l ig hting and distribution panelboards and for switchboards i n the protection of feeder and motor branch circuits. Trip Unit Rating Page 2 1 tM I nterrupt i n g R at i n g 1 5,000 Amps A c a n d 1 0,000 Amps De No n - I ntercha ngeable Trip Unit Class: Hi S hock M I L- S - 90 1 : 50'C Ambient I 29-220 and "hi". The "lo" setting is 500%-700% of conti nuous current rating. It is designed for De motor circu its and Ac feeder circuits. The "hi" setting is 1 200% - 1 400% of conti n uous current rating and is designed for appl ic a t i o n on A c motor circuits. T h e i ntermedi ate setting may be used to i ncrease lo setting tri p a mperes or decrease h i setting tri p a m peres a s may be required. ar A Q B -A1 01 a n d N Q B -A 1 01 B reakers Specificat i o n : M I L - C - 1 7361 1 5 - 1 00 Am peres 500 Volts Ac and 250 Volts De 3- P o l e Type Gl @ Gl Tec h n ical Data ua ls A p r i l 1 99 1 Su persedes Technical Data 29-220, pages 1 5- 1 6, dated Octo ber 1 978 M a i led to: E, C/29-200A .c om Westinghouse Electric Corporation Distri bution a n d Control B u s i n ess U n it E l ectrica l Com po n ents Division Pittsbu rg h , Pen n sylva n i a , U . S.A. 1 5220 Gl Complete breaker does not include mounting bases. Type required must b e ordered separately. @ Front connected bases include cable l ugs. Cover cable sizes 2828CM to 1 00,000CM . 0) breakers a r e furnished, f o r 2-pole applications m a k e connections to outside poles. @ Instantaneous tri p setting at 1 200-1 400% Hi o r 500-700% Lo. Set at Lo position at factory. ® M a n ufactured to meet M I L-C D or prior revisions o n l y . 17361 lec Only 3-pole P a nel board M o u nt i n g Type ww w .E Single Base Front Connected Single Base Rear Connected Single Base, Rear Connected, Line Front Connected, Load For use with rear connected fuse base Double Base Front Con nected Double Base Rear Connected Style N u m ber Weight 3 1 5C364G03 3 1 5C364G02 2.75 Lbs. 3.00 Lbs. 3 1 5C364G04 458D569G02 458D569G03 3.00 Lbs. 3.50 Lbs. 4.00 Lbs. A O B - A1 01 Breaker with Single Front Connected Base ... National Stock No. 5925-00-521 -2526 5925-0 1 - 1 24-0156 5925-00-728-5217 A O B - A 1 01 S i n g l e M o u nt; ng Base - Rear C onnected A O B - A 1 01 D o u b l e M o u nt ing Base Front C onnect ed ... National Stock N u m ber --+---- -----5925-00-397-8258 5925-00-546-3258 5925-01 -022-5086 Cl .c om Tech nical Data 29-220 Page 22 Fuse U n i t Assemblies I I Complete Fuse U n it Assembly 1 5-25 Amps 1 5-25 Amps 50, 7 5 , & 1 00 Amps 50, 75, & 1 00 Amps Front Rear Front Rear S h i p p ed As: Fuse UniteD Type Style N u mber AQB - F 1 01 A AQB - F1 01 A AQB - F1 01 B AQB - F1 01 B 504C01 0 H01 504C01 0 H01 504C01 0H02 504C01 0H02 I Fuse Unit Mounting Base Style N u m ber 655D258G01 ® 655D258G05® 655D258G03 655D258G06 w .E lec tri ca lP 372 B 1 55G01 372B1 55G02 372B1 55G03 372B1 55G04 Connection Rating ar Style N u mber tM an ua ls AO B - F1 01 A a nd AOB - F 1 0 1 B fuse u n its are designed for use in conjunction with standard A O B - A 1 0 1 circ u it breakers on circu its where a fa ult potential of u p to 1 00,000 a m peres exists. CD I ndividual fuses are not replaceable; replace with complete unit. ® To convert for use with high rating fuse unit (AQ B - F 1 01 B) in field, remove rejection pin per i nstructions on fuse u nit mounting base nameplate. ww Westi n g h o use E l ectric Corporation Distribution and Control B u s i ness U n it E l ectrical Compo nents Division Pitts b u r g h , Pennsylv a n i a , U . S .A . 1 5220 April 1 99 1 .c om 8 Tech nical Data Westingh ouse Electr ic Cor por ation Distribution and Control Busines s U n it E l ectrica l Compo nents Division Pittsb u r g h , Pennsylva n i a , U . S . A. 1 5220 29-220 Page 23 April 1 99 1 Supersedes Tech nical Data 29-220, pages 1 7- 1 8, dated October 1 978 Mailed to : E, C/29-200A Types AOB -A1 0 1 , N Q B -A1 01 , 250 Volts De, 500 Volts Ac, 1 00 Am peres M aximum, 1 5,000 Amperes I . C. Add i t i o n s S h u nt T r i p : B reakers c a n b e equi pped with a shunt trip attachment for tripping the breaker from a remote point, a nd can be suppl ied with coi l s for 1 20 volts, 60 cycle or for 1 20 volts De. These shunt trips have momentary rated coi ls a nd are suppl ied with a n auxil iary switch to be wi red in series for protection (Auxi liary switch i n D rawings Ava i l a b l e 900J 429 - M aster draw ing f o r breaker and mounting bases. 900J439 - M aster drawing for breaker with fuse unit a nd mounting bases. 459 D448 - O utline and wiring d i agram for breaker on single base. 654D255 - Outline and wiring diagra m for breaker with fuse u n it on single base. 459 D449 - Outline and wiring d i agram for breaker on double base. 654D256 - Outline and w i ring diagra m for breaker with fuse u n it o n double base. 657 0205 - For fuse unit mounting base only. cluded with t h e s h u n t trip. D o not o rder sep a r a te l y ) . Fo r 400 H z s h u n t t r i p co n t a c t Westinghouse. I n d iv i d u a l R e p ro d uctio n s: When req u i red, reproduction of master drawings, outline drawings and certification sheets can be ordered as follows : Shunt Trip - Volt age and Fre quency 4976D65G06 4976D65G02 4976D65G08 4976D65G04 1 20/60 1 20/Dc 1 20/60 1 20/Dc Thermal M a gnetic Thermal M a gnetic Magnetic Only Mag netic Only ua ls an tM 1 2 3 4 Full size photolithic tracing of master d rawing on vel l u m Outline and d r i l l i ng p l a n on vel l u m Certification data o n vellum Reproductions of items 1 , 2, o r 3 N et Wei g h ts, Lbs. A O B - A 1 0 1 - 6.00 N O B -A1 0 1 - 5.75 AQ B - F 1 01 A - 2.00 AO B - F1 01 B - 2.00 Fuse U n it M o unti n g Base - 3.00 Or d er i n g I nfor matio n : See page 4. lec tri ca Auxi l i ar y Switc h : B reakers can be sup plied with i nternally mou nted auxiliary switch to open or close control circuits as breaker operates. Each switch provides one "A" contact and one "B" contact. "A" con tact is closed when breaker is closed, open when breaker is open. "B" contact is open when breaker is closed and closed when breaker is open. When ordered with one switch it is n o r m a l ly mou nted i n r i g ht pole, may be specified mou nted i n left pole. A m a xi m u m of 2 switches can be s u p p l i e d : one i n left a n d o n e i n r i g ht pole. O rd e r by descripti o n . D escription ar Shunt Trip Breaker Type Style N u m ber Item lP To order, specify style n u mber of standard breaker required plus style number of shunt trip attachment from table below. ( M ust be factory i nstal led.) .E No te: O ne a u x i l iary switch norma lly s u p pl ied w i t h s h u n t tri p attachments for cut-off switch and additional switches can not be supplied on breakers with shunt trips. Handle Lock: When specified, o rd e r sty l e 1 6 1 4485. Handle Boot: When specified, o rd e r sty l e n u mber 752B729H01 . w Rear Stud: Complete with 4 nuts, styl e n u mber 208B801 G 0 1 . ww F u n g u s - Mo istur e Resistant Tr eatment: (JAN -T- 1 52, J A N - C - 1 7 3 or M I L- V- 1 73) . If specified, contact Westi ng house. External parts are coated. Tech nical Manua l : Navships No. 362-23 1 4. T h i s b o o k l e t p e r M I L - M - 1 5 07 1 . W h e n requi red, order BVR-TM-475C. AB DE-ION® Circuit Breakers for Naval Shipboard Use .c om Technical Data 29-220 Page 24 O ut l i n e D i m ensio n s, A Q B - A 1 01 Breaker S i ngle Breaker ( R ear Mounted) For S i ngle Breaker Mounted Base 5� r an 61 2 ua ls Copper extensions for megger readings. Copper extensions 1*---- can be broken off with pliers if not neede�d�·--.-L-•��� I 2� 8 32 3 1@ 6 tM m ate 19 ar f • :s C ir cu it Br eaker Handle Lo c k i n g Device Dr i l l i n g P la n ww w .E lec tri ca lP For Single Mounted Base ������d ea ke r ou tl in Br Reverse position of lock to breok""'m""";"g e OFF 1�Dia. megger test holes Westinghouse style 1614485 ( Not supplied with circuit bkr.) 1 4 316lP 9 132 �--�----�--�. L----L--�_j __J .098 Dia. hole for handle locking device or warning tag Westi nghouse E l ectric Corporation Distri bution and Control Busi ness U n it Electrical Components Division Pittsburgh, Pen nsylva nia, U . S . A. 1 5220 Apr il 1 991 29-220 Page 25 Types AOB-A1 0 1 , N O B -A1 0 1 , 250 Volts De, 500 Volts Ac 1 00 Amperes Maximum, 1 5,000 Amperes I . C . AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls April 1 99 1 S u persedes Tech nical Data 29-220, pages 1 9-20, dated October 1 978 Mai led to: E, C/29-200A .c om 8 Technical Data Westingh ouse Electric Corporation Distribution a n d Control B u s i n ess U n it Electrical Components Division Pittsbu rg h , Pennsylva n i a , U . S.A. 1 5220 AQB-A1 01 Breaker Mounting Bases For Double Mounting Base Front Conn ected For Two Breaker Mou nting Base Between !i_ of next base Complete hardware supplied except far copper bus bars lec tri ca lP ar tM an r4� For Double M o u nting Base Rear Connected l2 Dio. mtg. hole .E 17 ' 32 C bore ( 6 holes l Fr o nt Cover Cutouts For Dou ble Mounting Base ww w Base outline Round head screw Coble entrance Complete hardware supplied except for copper bus bars .c om Technical Data 29-220 Page 26 Outline Dimensions, Cont i n u ed AQB-A 101 Breakers, Single Base with Fuse Unit For Mounting of Breaker ( Front Connected) I - tr@ � r 0 t " cd,! "" I / 16 R 61J 1 6 @: �-� �rr � �·I ��lli �-��- � -1---=-- 24 ��8 � --I I 3 � 4+-- 1 16 --1 � 3�8 - ---+1 -t? 8 �[ Rejection screw A ! "' ! el ,, i 1 2- I � 90-32 Inserts ( 2 l for fuse pul l e r screws - AQB-A I O I �i;l; � f ' n� ---- �:=•w ' 1 5 6 00 ' l j . : '' lit=::-== -- ---=---=- ' I I " AQB - FIOIA or AQB - FIOI B II _-, : 'I 'I 1 - -- - -- ---- - � t 2- - _:frt---L- li L �� � ' tl � ' ..JTI rn ' ' _s2 L � 11 u �@ 16 I 6 16 6 n co T - r ) r---=· � I '-ur I ::J 6 cu- r I �- 23 32 Mox. across corner s _-1f R ' - -- -- --------- ar tO '--- '---' � � ��=+====� :I I � For Dimensions of Breaker and Mounting Base See Drawing N u m ber 459D448 L� a.-- � �_co l � -u-u-1 b 32 IIL I = Is 9, ' I nsulation sheet ( not suppl ied ) p �- 16Th d. l-- 2 12 Terminal for M i n imum Navy Cable Thfa-3-2828 C . M . and M a x i m u m Navy Thfa - 1 00 - 1 00,000 C . M . 3�4 - ca 62l l s4 T hick insulation recommended lP 'l' 4 Front Panel ---! I 2 16 @ 61 ua ls � an / � � 4 UiE . ,-/1 For Mounting of Breaker ( R ear Connected) tM Copper extensions for megger readings ( may be broken off if not requ i red ) D ri l l i n g P l a n ww w .E lec tri F o r R ear Connected Studs and M ounting Bases I 4-20 Tap (6 holes) for mounting bases ------�-- 2 � 4 1� Dia. megger ( 3 holes) 2�4 't_of Breaker Front Panel C utout West i n g house E l ectric Corporation Distri buti o n and Control Business U nit E l ectrical Components Division Pitts b u rg h , Pen nsylva nia, U . S . A. 1 5220 Apri1 1991 i-:�-: 33i�- ft- - For M o u nting of Two Breakers ( Front Connected) 61 4...,1,...1 !-- 61�--"'l _ r f.. I -- �-------l �,� ��u� em� e � ----------- -��� u�� �� ,m� � 6r_l tM @ E==+=====-l ,__.., I 2) . 1 0-32 Inserts( for fuse puller screws ""� t-� p �I �3r�% -, 16 c ���-����:-- -� For Dimensions of Breaker and Mounting Base See Drawing Number 459D449 ,-----13] 6 I I -� I b I !I , ._ !> Ill: - [,� _ _ _ _ U �' T x � Ma . across corners ]: .I ------ - -- --- -- - pu 1 5§ ar 6J cfJ cJ:J ; ___;_t_ -i-' 2� recomm ended - - - -- - - lP 6� I ... AOB - F IO I A or AOB-FIOIB . i� Thick Insulation ' rr 932 tri 10 11 � 7 JI 1 ,-! f For M o u nting of Two B reakers ( Rear Connected) ca 20 j::- � l6 AB DE-ION® Circuit Breakers for Naval Shipboard Use an �� 4 Page 27 ua ls A O B -A1 01 B reaker, D o u ble B ase with Fuse U n its 13 29-220 Types AQB-A1 0 1 , N QB -A1 01 , 250 Volts De, 500 Volts Ac 1 00 Amperes M a ximum, 1 5,000 Amperes I. C . April 1 99 1 Supersedes Technica l Data 29-220, pages 21 -22, dated Octob e r 1 978 Mai led to: E, C/29-200A r .c om Cl Technical Data Westinghouse Electric Corporation Distri bution and Contro l Busin ess U n it E l ectrical Components Division Pittsburgh, Pen nsylva n i a , U . S . A. 1 5220 Terminal for Minimum Navy Cable Thfa-3-2828 C . M . a n d Max•mum Navy Thfa - 1 00 - 1 00.000 C . M . lec ,.:-----c;----------- 1 91� --------�l 1'106 Min. d i a . ( 6 holesl tor �----9� -----�·· rear connected stud I .E D r i l l i ng P l a n For Rear Connected Studs and Mounting Bases 2 . 50-20 Tap ( 10 holes l for mounting bases 32 ..... ww w II i Front Panel Cutout r--- 243 I 1'1 lL : L J I 2 f-- 1 _ 6196 I - , [( . [( I( ' _) - - �- ., _ .) HJ+IJ �- z 15-1 16 - 2 �� 16 - 2�3 - 6196 T \ - Breaker outline II -32 l I .i 'If \ ! 3 1 1 a !3_ T T 13 16 �� 1 !4 1� Diameter megger ( 6 hole sl Techn ica l Data .c om 29-220 Page 28 Characteristic Curves 400 Cycle B reakers 40 30 20 \ -- Instantaneous \ \ ' \ i= <.!> 40 30 20 15 10 ' 1 0 0 N 0 0 r0 Percent Rated Current 0 0 <t 0 0 tO V> J!i " ""' c (!) I ' 0 0 0 0 0 O perating C h a racteristics Trip U n it Rating 1 5- 1 00 Amperes 50'C Ambient - Cold Start, 60 Ac or De, Thermal M a g netic 0 0 0 0 0 0 <0 0 a) 9 I 0 0 0 0 2 0 :ii N Trip U n it R at i n g I I I 70 I I 0 0 lil 0 0 � 60 50 D c 0 u '" (f) 0 0 s; \ \\ I 40 30 � 20 15 10 - 0 0 0 0 Percent Rated Current 5 4 3 2 tri 10 1.0 1.5 2.0 2.5 3,0 3.5 4.0 4.5 To determine the trip unit rating to be used, when the load current and ambient are known, multiply the load c u rrent by the fac tor obtained from this curve for the known ambient. The result will be the ideal trip unit rati ng. However, since trip u n its are fur nished only with standard ratings as per Navy spec., select the standard trip u n it whose rating is equal to or one rati ng higher than the ideal rati ng. ,\. ', 0 0 0 0 c0 g- N \ <.!> D c 0 u <l) (f) '� ·�'' ', ' , ' I I 0 0 0 0 0 0 ill C!J 0 0 0 0 0 "' 0 - N 0 0 0 r0 - - - 400 Hz Instantaneous Trip at 1 200% to 1 400% Rating ' 1\ \I \ <l) 20 0.5 \. 5 4 3 2 I E i= 30 lec .E 5 4 3 40 Factor Instantaneous Trip at 850% to 1 1 50% Rating '\ \I \ 1 40 30 20 ca Specification M I L- C - 1 7361 This specification covers all thermal mag netic AQB breakers. It req uires that they carry 1 50% of c u rrent ratings for at least one hour and that thermal elements i n itiate tri p ping at 225% rated current with i n one hour and at 600% i n 2 5 seconds p l us or minus 25%. The instantaneous mag netic setti ngs for each continuous ratings are based on in tended applications. (Thermal tri pping tests are conducted with all poles in series i n 5 0 ' C ambient; e a c h p o l e is tested individ ually to check magnetic settings.) 0 0 0 0 w 0 V> II 80 ' 10 I Operati n g C h a racteristics Trip U n it Rating 1 5 - 1 00 Amperes 50'C Ambient - Cold Start 400 Cycle Ac, Thermal Mag netic 90 Cycle, 0 0 co 0 ;;; � Per Cent Ra t e d C u r r e n t :I I: E i= I I 5 3 2 i 0 0 \. 5 3 2 '-\'\ 5 4 3 2 1 40 30 20 \ \ 10 I 40 30 20 15 10 \. 1 "0 c 0 u <l) (}) � \ \\ E 0 c Tri p at 500% to 700% Rating 1\ <l) � - - - 60 Hz Instantaneous Trip at 1 700% to 2300% Rating an l 1\ I 50 40 30 20 tM \ - - - I nstantaneous Tri p at l200% to 1400% Rating 5 4 3 2 ar 4 3 2 G enerator B reakers lP :::> 0 I ::' :> 4 3 2 ua ls A O B - A1 01 B reakers - Instantaneous Trip at 500% to 700% Rating \ \\ 1 40 30 20 15 10 ·' 5 4 3 2 '\") II It 1 0 :2 0 0 N 0 0 0 0 r0 q Percent Rated Current 0 0 0 0 0 0 w oo g 0 0 "' - 0 0 0 N 0 0 0 r0 5 0 ° C Ambient Cold Start, "G" rati ng, 60 or 400 Cycle Ac, or De - Thermal Mag netic ww w Westi nghouse E l ectric Corporation Distri bution and Control B u s i n es s U n it E l ectrical Components Division Pittsburgh, Pen nsylva n i a , U . S . A. 1 5220 April 1 991 .c om Tec h n ica l Data Westinghouse Electric Corporation Distribution a n d Control Busi ness U n i t E l ectrical Components Division Pittsburgh, Penn sylva n i a , U . S.A. 1 5220 April 1 99 1 Supersedes Tech nical Data 29-220, pages 23-24, dated Octo ber 1 978 Mailed to : E, C/29-200A tM AOB-A250 breakers can be ordered with undervoltage release devices, a u x i l i ary switches and shunt trip attachments com plete with auxiliary switc h . These attac h ments are also easily i nstalled i n the field. ar AO B - A250 circuit breakers are used pri marily to protect feeder circuits, however, those foll owed by "N M"" in the price table have higher magnetic settings to a l l ow for motor starting. B reakers with settings spe cifically for use with generators are desi g nated " ' N G " i n t h e price table. an These breakers are available with i nter changeable trip units i n ratings of 1 25, 1 50, 1 7 5, 225 and 250 a m peres. The n o n automatic N OB -A250 carries a 250 a m pere rating and has copper cond uctors re placing the trip unit. Special gen erator breakers have trip u n its rated at 1 00, 1 60, a nd 250 a m peres. I nterrupting R at i n g s 20,000 Amps Ac and 1 5,000 A m p s De Low High De Low High I Complete Breaker CD De Two-Pole 500 Volts Ac, 250 Volts 225-N 225-N M 250-N 250- N M 250® 650 1 950 650 1 950 650 1 950 1 1 300 3900 1 300 3900 1 300 3900 650 1 300 1 500 3000 650 1 300 1 700 3400 Non-Auto 1 650 2250 650 2250 650 2250 1 300 41 00 1 300 4 1 00 1 300 4 1 00 650 1 300 1 770 3550 650 1 300 1 850 3800 Non-Auto 1 31 3C682G03 31 3C682G04 31 3C682G05 31 3C682G06 31 3C682G07 31 3C682G08 De . . . . . . . . . . . . . . . . 650 1 300 31 3C682 G 1 3 3 1 3C682 G 1 4 31 3C682G 1 5 Three-Pole 500 Volts Ac, 250 Volts 650 1 950 650 1 950 650 1 950 De 1 300 41 00 1 300 4 1 00 1 300 4 1 00 31 3C682 G 1 8 31 3C682G 1 9 31 3C682G20 31 3C682G21 31 3C682G22 31 3C682G23 5925-00·248-1 425 5925-01 ·031 ·9909 5925-01 -229-4448 650 1 300 1 770 3550 650 1 300 1 850 3800 Non-Auto 31 3C682G24 31 3C682G25 31 3C682G26 31 3C682G27 31 3C682G36 5925-0 1 - 1 73-2587 5925·01·210-5267 650 2250 650 2250 650 2250 1 300 3900 1 300 3900 1 300 3900 .E 1 25 - N 1 25 - N M 1 50 - N 1 50 - N M 1 75 - N 1 75 - N M 225-N 225-NM 250-N 250-N M 250® 1 650 1 300 1 500 3000 630 1 300 1 700 3400 Non-Auto 1 1 w Three-Pole 500 Volts Ac, 250 Volts 1 1 7 5 2350 1 950 3900 . . . . . , , . ww 1 00 - N G 1 60 - N G 250 - N G . . . . . . . . . . . . . . . . 650 1 300 Breaker Frame OnlyCD 1 1 \ Trip U n i t Only Style N umber Style N u mber National Stock No. 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 5925-01 -796-4371 5925·0 1 -796-437 1 5925·0 1 -796-437 1 5925·01-796-4371 5925-01 -796-4371 5925·01 -796-437 1 4520371 G03 452D37 1 G04 4520371 G05 5925-00-793-6865 4520371 G06 4520371 G07 5925-00- 175-5058 4520371 GOB 452D370G01 452D370G01 452D370G01 452D370G01 452D370G03 5925·01 -796-4371 5925-0 1 -796·4371 5925-0 1 -796-4371 5925-0 1-796-4371 4520371 G09 452D371 G 1 0 452D37 1 G 1 1 452D37 1 G 1 2 29B271 0G05 452D370G01 452D370G01 452D370G01 5925·01 -796-4371 5925-01 -796-4371 5925·01 -796-4371 4520371 G 1 3 452D371 G 1 4 4520371 G 1 5 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-QQ. 789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 4520371 G 1 8 4520371 G 1 9 4520371 G20 4520371 G21 4520371 G22 4520371 G23 5925-00-795-4958 5925-00-839-0289 5925-00-795-4957 5925-00-839-0290 5925-00-796-4439 ............. . 452D370G02 452D370G02 452D370G02 452D370G02 452D370G04 5925·00-789-37 1 8 5925·00-789-3718 5925·00-789-37 1 8 5925-00-789-37 18 5925-00-83 1 ·8801 4520371 G24 4520371 G 2 5 4520371 G26 4520371 G27 298271 OG06 5925-00-839-0291 5925-00-839-0292 5925-00-839-0293 5925-00-690-7568 5925-00-831 -8800 4520371 G28 4520371 G 2 9 4520371 G30 5925-00-852-7809 5925-00-795-4956 . . . . . . . . . . . . .. National Stock No. 5925-00-064-7834 Generator Circuit Breaker Applications lec 1 1 7 5 2350 1 950 3900 . . . . . . . . I . .. . .. 31 3C682G09 31 3C682G 1 0 31 3C682 G 1 1 31 3C682 G 1 2 31 3C682G31 Two Pole 500 Volts Ac, 250 Volts 1 00 - N G 1 60 - N G 2 50 - N G 5925·01 -233-6525 ........... . tri 1 25 - N 1 25- N M 1 50 - N 1 50- N M 1 75 - N 1 75 - N M National Stock No. Style N umber ca I lnst. Trip Setting - Amps lP List Prices See Price List 29-020 Ac AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls S pecificat i o n : M I L- C - 1 7361 1 25-250 A m peres 500 Volts A c and 250 Volts De Two and T h ree- Pole l Page 29 Types AOB -A250, N Q B - A250 250 Volts De, 500 Volts Ac 250 Amperes Maximum, 20,000 Amperes I . C . A Q B - A250 a n d N Q B -A250 B reakers Cont. Ampere Rating 29-220 De · · · · · · · · · · · · · · 5925-0 1 ·235-07 1 8 5925-0 1 · 1 92·3985 5925-01·272-3805 ... . ...... .... 1 Generator Circuit Breaker Applications 31 3C682G28 31 3C682G29 31 3C682G30 5925-01 -080-2226 5925-0 1 - 1 04-4625 .. .. .. .. . . . . . . 452D370G02 452D370G02 452D370G02 5925-00-789-37 18 5925-00-789-3718 5925-00-789-37 1 8 1 Note : Breakers with ratings other than than those g iven on this page are considered as special and full description data must be provided. Styles listed include sli p-type connectors for rear connections. Order front terminal con nectors separately if required; see page 30. No additional charges for front connectors ordered with breakers or frames. CD ® Type NQB-A250 non-automatic. Tech nical Data .c om 29-220 Page 30 AQB-A250 and NQB-A250 Breakers, Conti n u ed List Prices S ee Price List 29-020 Instantaneous Tn p Settmg in AmperesGl low H igh I Breaker Frame Only® Complete Breaker® National Stock No. Style Number Style N umber National Stock N o . 452D370G01 452D370G0 1 452D370G01 452D370G0 1 452D370G01 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-437 1 5925-00-796-437 1 400 Cycle, Two-Pole, 500 Volts Ac 1 25 - N H 1 50 - N H 1 75 - N H 225-N H 250- N H 1 91 0 91 0 91 0 91 0 91 0 1 1 1 1 1 560 560 560 560 560 1 31 5C574G03 31 5C574G05 3 1 5 C574G07 3 1 5 C574G09 3 1 5C574G 1 1 1 400 Cycle, Two-Pole, 500 Volts Ac Generator Circuit Breaker Applications 3420 3420 4200 31 5C574 G 1 3 31 5C574G 1 4 31 5C574 G 1 5 .. .. .. ........ .. .. .. .. .. .. .. .. .. .. .. .. .. .. 400 Cycle, Three-Pole, 500 Volts Ac 910 910 91 0 910 910 1 25 - N H 1 50 - N H 1 75 - N H 225 - N H 250- N H I 1 560 1 560 1 560 1 560 1 560 1 31 5C574G 1 8 3 1 5C574G20 31 5C574G22 31 5C574G24 31 5C574G26 5925-01-075-8931 5925-0 1 - 1 00-4027 5925-01 - 1 93-6055 1 452D370G01 452D370G01 452D370G01 5925-00-796-437 1 5925-00-796-437 1 5925-00-796-437 1 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 400 Cycle, Three-Pole, 500 Volts Ac G enerator Circuit Breaker Applications 1 00- N G H 1 60 - N G H 250- N G H 2020 2020 2520 3420 3420 4200 31 5C574G28 31 5C574G29 3 1 5C574G30 ... .. .. .. .. .. . ..... .. .. .. ... ..... .. ... . .. . 452D370G02 452D370G02 452D370G02 Style Number National Stock No. 457D446G03 457D446G05 457D446G07 457 D 446G09 457 D446G 1 1 . . .. .......... ......... .... . · · · · · · · · · · · · · · .. .. ....... .. . .............. · · · · · · · · · · · · · · 457D446G 1 3 457D446 G 1 4 457D446G 1 5 5925-00-758-6227 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 457D446 G 1 8 457D446G20 457D446G22 457D446G24 457D446G26 5925-00-803-5491 5925-00-803-5488 5925-00-899-9904 5925-01 - 1 93-6056 5925-01 - 1 49-4269 5925-00-789-37 1 8 5925-00-789-3718 5925-00-789-37 1 8 457D446G28 457D446G29 457D446G30 5925-00-238-5198 5925-00-803-5489 ... .... .. . .... an 2020 2020 2520 tM 1 00-NG H 1 60 - N G H 250-NG H Trip Unit Only ua ls I Cont. Ampere Rating · · · · · · · · · · · · · · I One Stud Assembly complete with 4 nuts Terminal Mtg. Block (No Studs) Mounting Block and Stud Set (3 Studs) Style N u mber National Stock No. lP Description ar Switchbo a rd Mo u n t i n g Complete breakers and frames i nc l ude mounting hardware. Female s l i p conn ectors are mou nted i n breaker base to plug onto stud projections of term i n a l mounting block asse m blies. Order one m o u n t i n g block assembly f o r e a c h end of breaker. I I ca 1 631 443 31 3C681 G01 3 1 3C680G02 ( N et Weight - 2% lbs.) F ro nt Co n nected B reakers For connections made at front terminals, pressure-type l u gs req u i red . If specified on same order, conn ectors furnished no charge. One con nector per term i n a l . Select below. Cable Amps Description Style I National i � �� 250 - 1 75 I i I I tri 1 N40-N75 N1 OO- N 1 25 N 1 50- N200 I Solderless Connector I I N umber 20B3055 H 1 4 20B3055H 1 5 20B3055 H 1 6 I Stock N o . T------------------- lec I Range K i t to C o nvert A Q B Frame to N Q B B reaker 3 Style N u mber National Net __ e ig h__ St oc k N o . ____rW t �_ ----r-______ 29B271 OG06 ... .. . ... .. .. . % lb. .E Poles Gl For 400 cycle breakers with higher instantaneous trip rati ngs, refer to Westi nghouse. @ Styles listed include s l i p-type con nectors for rear connections. Order front terminal con nectors separately if required. No additional charges for front con nectors ordered with breakers or frames. ww w Westinghouse E l ectric Corporation Distribution and Control Busines s U nit Electrical Components Division Pittsburgh, Pennsylva nia, U . S . A. 1 5220 April 1 991 8 Westinghouse Electric Corporation Distribution a nd Control B u si n ess U n it E l ectrical Compon ents Division Pittsburgh, Pen nsylv a n i a , U .S.A. 1 5220 April 1 99 1 S u pe rsedes Tec h n ical Data 29-220, pages 25-26, dated Octo ber 1 978 M a i l ed to: E, C/29-200A Types AOB -A250, N O B - A250 250 Volts De, 500 Volts Ac 250 Amperes Maximum, 20,000 Amperes I . C. - M o ist u re - Resistant Treat (JAN -T- 1 52; JAN - C - 1 7 3 or M I L If specified, contact Westi ng house. parts are coated; tri p u n its are not lec .E w 24- 32 90-1 30 1 I .c om Style N u m ber 452D377G05 tM 28 V De 1 1 5 V Ac Voltage Range an I 1 20 V De 450 V Ac 90-1 30 360-500 I 452D377G07 I National Stock No. 5925-00-831 -8808 5925-01 -007-5836 U n dervoltage Device: Automatically trips breaker when l i ne voltage drops below 40 to 60% of norma l . After u ndervoltage coil has dropped out and tripped breaker on reduced voltage, it automatica lly resets by breaker action. ( If undervoltage coil is energized to 80% of norm a l ) . Select device below. Net weig ht., 1 . 1 2 l bs. Nominal Voltage 4 5 0 Ac, 60 Cycle 250 De 33 De I Voltage Range I 360-500 Pickup and Seal Volts ( M in i m u m ) 360 1 75-355 30- 36 1 50 22 I Dropcut Voltage Style N umber National Stock N u mber 290 45 25 5 452D837G01 5925-00-920-3099 452D837G02 452D837G03 5950·00-790-4869 Max. M in. M in. M in. I n d i v i d u a l R e p roductions: When req uired, reproduction of master drawings, outl i n e drawings and certification sheets can be ordered as follows: Item I Description 1 2 3 4 tri Technical Manual - NAVSHIPS No. 3622 1 64: This booklet per M I L- M- 1 507 1 . When req u i red, order BVR-TM-379A. ww AB DE-ION® Circuit Breakers for Naval Shipboard Use ca Fungus ments: V - 1 73) : External treated. Nominal Voltage ar A u x i l iary Switch : If required, style 452D379G 02, national stock number 593000-732-8401 . I nte rna l ly mou nted switch is used to open or close control circuits as breaker op erates a nd is provided with ' 'A" and " B " contacts. "A" contact is normally closed when breaker is closed and open when breaker is open; "B" is norm a l ly open when breaker is closed and closed with breaker open. It has the fol lowing rat ing at given voltages : 1 5 amp - 1 2 5, 250 or 460 volts Ac; % amp- 1 25 volts De; '!.. a m p - 250 volts De. Net weight, . 1 7 lb. Page 3 1 S h u nt Tri p : Shunt trip attac h ments for tripping the breaker electrica l ly from a remote point are listed i n table below. Shunt trips have momentary rating only and for protection must be connected i n series with a u xil i a ry switch. Auxiliary Switch (style 452D379G02) is included i n shunt trip n u m ber shown below. Do not order separately. Net weig ht, .70 lb. lP M echan ical I nterlock : If mechanical i nterlock (switchboard use) is desired for a pair of breakers, order by description. ( N ot subm itted for Navy approva l . ) 29-220 ua ls AOB -A250 a n d N Q B - A250 B reakers, Contin ued Additions H a n d l e Loc k : If required, order style 1 7 201 0 1 . O ne furnished no charge per 1 0 breakers ordered, when requested. Net wt., . 1 5 1b. Tech n ical Data I I Full size photolithic tracing of master drawing on vel l u m Outline a n d d r i l l i ng plan on v e l l u m Certification data o n vel l u m Reproductio n s o f i t e m s 1 , 2 , o r 3 D rawings Ava i l a b l e : Master draw i n g 900 - J -376; front and rear connected breaker out line, drilling and wiring diagra m 4 5 2 - D -834. O rderi n g I n format i o n : Page 4 Net We i g ht, Lbs. AOB Complete, 3 - Pole A250 NOB Complete, 3 - Pole N 250 3 - Pole AOB, N O B Frame AOB Trip U n it, 3 - Pole 20.50 1 7 .50 1 7.00 3.50 .c om Cl Technical Data 29-220 Page 32 O ut l i n e D i m e n s i o n s AQB -A250 B reaker line End Front face of mounting sheet or channel Supp o r t blocks ore not supplied wtth breaker:,_ but must be ordered separately. t<efer to drawing 313C680 Al l ports necessary to nvert o breaker ore included . 3 a·16Stud I '--4f-----''---+--+-+ 4-20 Mtg. ua ls ;i. 2 16 ----+--+--+ -t--����:J�K=!B=f��T�co Screws A Frome Nameplate load End Warning Nameplate Front Sheet See wiring diagram and dril ling pion 4 ar Visible amp rating interchongeo ble trip unit tM an 11 Handle loc king Device ( N ot S u pplied With C i rc u i t Br e a ke r ) Nuts and 1 washer supplied with stud � .k--1 3 [' _J�r--T Cable Range A B MCM 76 20B3055H14 c M in .E Max 50 1 211A. 6"h. 5"h. 20B3055 H 1 5 1 25 1 00 13 6"A• &'A. 20B3055H 1 6 200 1 50 1 3'/.• 7'hz 6'hz Front Connected Terminals are not Supplied with Circuit Breaker w 1 oia. 3 holes for megger test ore on 24 centers Front Con nected Solderless Terminals Identification Style Number i Reor connections � ore on 3"centers Front co� nections lec I 15 tri Flat washers, lock washers and nuts supplied with terminal mounting blocks ca lP Front Sheet D r i l l ing Template Wiring D iagrams AQB NQB Line End Line E n d JU }{{ load End load End �)) When U nder-Voltage Release is Provided r - - - - - - - -, i : 1 I 1 i ?. Y. : 1 L__ _ .- : Undervoltoge --J re lease ? , leads 18 long - ----- -, i l l l : i' i' l. ) )) i A and 8 A uxi l i ary SWitCh 3 leads I 18" long ----- : : m� 1 When S h u n t Trip and Auxiliary Switch is Provided I �w�\ L. • _ _ _ Note: The auxiliary switch must be used with each shunt trip. Connect one side of shunt trip i n series with "A'' contact (Closed when breaker is closed) of auxiliary switch when connecting to power supply. : J Shunt trip 2 leads 18" long ww Westing house E l ectric Corporation Distribution and Contro l B u s i n es s U n it E l ectrical Compon ents Division Pitt sb u rgh, Pennsyl vania, U . S .A . 1 5220 April 1 991 April 1 99 1 S u persedes Technical D a t a 29-220, pages 27-28, dated October 1 978 M a i l e d to: E, C/29-200A 29-220 50 8 6 Time I I 50 25 Seconds+ 2 5 % Less Than 1 Hour 600 225 1 50 20 I II I I Tripping 20 10 8 6 M i n i mum 40 Maximum Minimum 20 20 8 6 10 8 6 10 ' 4 3 I Tripping Time I to 2 M m 5 to 15 Min. = - _ 2 0 M m o r More 5 3 2 I 40 0 5 " ·"'- 20 • • 10 4 5 3 2 I \1\. \ \ 1\ 10 4 0 o o o o � Per Cent Rated Current o 2 � � o o o g �� jI • • o o o � g g - N rn O perati n g C h a racteristics Trip U nit Rating 1 25 -250 A m peres 5o·c Ambient - Cold Start 400 Cycle Ac I ca 40 1\ I 4o o 20 M a x i mum lP 4 3 4 3 2 tM I 40 I ar 4 3 1\ Percent of Tr i p Element Ratings 150 10 4 3 I III I I 300 200 30 More Than 1 Hour I II I I ua ls I II I I II 30 4 0 0 Cycle B reakers A O B - A250 G e nerator B reaker Percent of Trip Element Rating AB DE-ION® Circuit Breakers for Naval Shipboard Use an I Page 33 Types AQB-A250, N Q B -A250 250 Volts De, 500 Volts Ac 250 Amperes Maximum, 20,000 Amperes I . C . C h a racterist i c C u rves A O B - A250 I .c om Cl Techn ica l Data Westinghouse Electric Corporation Distribution a n d Control Busi ness U n it E l ectrical Components Divi sion Pittsb u rg h , Pennsylva n i a , U . S . A. 1 5220 40 20 Trip U n i t R a t i n g 20 10 7 "' 7 0 0 0 0 0 00 0 0 0 0 0 0 0 o o o oo o o o o o o o o l{') - - N 1"1 ¢ ,,nu; CD 0 Ill 0 0 0 0 0 0 0 0 0 00 0 0- 0 0 0 9. �- 2- �- lec I .. .6 .5 Percent Rated Current - - N 1"'l V lD .E Operati n g C h a racteristics Trip U n it Rating 1 2 5 - 250 Amperes 5o·c Ambient - Cold Start, 60 Cycle, Ac or De ww w Specification M I L- C -1 7361 This specification covers all thermal - mag netic AQB breakers. It requires that they carry 1 50% of cu rrent ratings for at least one hour a nd that thermal elements initiate tri pping at 225% rated cu rrent with i n one hour and at 600% i n 2 5 seconds plus or minus 25%. The instantaneous mag netic setti ngs for each conti nuous rati ngs are based o n intended applications. (Thermal tri pping tests are conducted with all poles in series i n 5o·c ambient; each pole is tested individually to check magnetic settings.) 90 5 tri u ,.. u I0 3 I B .6 5 o oo O ll'l o - -N o o oooo o o o o o o o oo o o o o o o o 1"1 o;t ii'HD CD0 11') 0 0 0 0 Percent Rated Current - - N ff1 -.t iD I I 80 1\ 2 70 o oo o o ooo O O �Q �- Q :-�f � 60 50 40 30 Ope rati n g C h a racteristics Trip U n its, Types 1 00 N G H , 1 60 N G H , 250 N G H , 1 00 N G , 1 60 N G a nd 250NG for use with generator circuit breakers 5 0 ° C a m bient - C o l d Start A c o r D e 20 10 0 o 0.5 Foelor 1.0 1.5 2.0 2.5 3,0 3.5 4.0 4.5 To determ ine the trip u n it rating to be used, when the load current a nd a m bient are known, m ultiply the load current by the factor obtained from this curve for the known ambient. The result will be the ideal trip u n it ratin g . H owever, since trip u n its are furnished only with sta ndard rati ngs a s per Navy spec., select the standard trip u n it whose rating is equal to or one rating hig her than the ideal rati ng. Technical Data .c om 29-220 ca lP ar tM an ua ls Page 34 "C �· .E lec tri 0. ww w Westi n g h o u se E l ectric Corporation Distributi o n a nd Control Busi ness U nit Electrical Compon ents Division Pittsburgh, Pennsylv a n i a , U . S.A. 1 5220 April 1 991 .c om Tec h n ica l Data 29-220 Westinghouse Electric Corporation D i st r i bution a n d Control B u s i ness U n it E l ectrical C o m p on ents Division Pittsb u rg h , Pen nsylva n i a , U . S.A. 1 5220 Apri l 1 99 1 Su persedes Tec h n ica l D a t a 29-220, pages 33-34, dated October 1 978 M a i led to: E , C/29-200A ar lP ca tri A Q B - L F250 fused Navy circuit breaker .E w Fuse Tri p ww Desc r i p t i o n These breakers are essentially sta ndard N avy circuit breakers i n corporating current l i mit ing fuses i n o n e compact device. The fuses are m o u nted in a removable m o lded hous i n g which plugs i nto and becomes a n i n tegral part o f the breaker. Fuses a r e easily replaced from the front si mply by loosen i n g f o u r screws and p u l l i n g o u t the f u se housing. Lever Instantaneous Trip Adjusting Wheels Sl ide Type Connectors for Fuse Contacts A n i nter l o c k prevents t h e breaker being cl osed i f a n y of the three f u ses are blown and the fuse housing is so desig ned that all three fu ses m u st be u n blown before the housing c a n be mou nted in its correct posi t i o n on the breaker. Removal of the fuse h o u s i n g a u to m at i c a l l y o pens breaker and provides visua! assura nce that the circuit is discon nected . O p e r a ti o n The the rmal mag netic tri p u n it of the sta n d a rd breaker provides protect i o n o n overloads and s hort c i rc u its oelow a predeterm i n ed value without affect i n g the f uses. H owever, these spec i a l ly coord i n ated fuses assu me the fault clearing d uty o n high m a g n itude s hort circ u its and extend the i nterru pti n g capacity to 1 00,000 a m peres. The co m m o n trip feature of the circuit breaker is retained so that all poles open when any fuse blows. Fast acting cu rrent limiting fuses clear sh ort circu its i n less t h a n one- half cyc le. Co nseq u e ntly, p e a k let thro u g h c u rrents are g reatly reduced and bus-s u p porting members or c u rrent carrying parts do not have t o be designed t o meet maxi m u m peak c u rrent. lec A Q B - L F 1 00 fused Navy circuit breaker Note: AQB-LF100 breakers are sold for replacement only. They are no longer on Navy Qualified Product List. an L i k e sta ndard N avy breakers, they a r e d e sig ned f o r u s e i n switc h boards, l oad centers and panelboards. AOB- LF circuit breakers are available in t h ree-pole desi g n and for rear con nection o n l y. tM A Q B - L F1 00 a n d A Q B - L F250 B reakers A p p l i cat i o n AQ B - LF 1 0 0 a n d AO B - LF250 circuit break ers are for use in low vo ltage distribution systems where avai lable fault c u rrent ex ceed the i nterru pti ng ratings of standard m o lded case breakers but does not exceed 1 00,000 a m peres. AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Type AOB- L F 1 00, 1 00 A m peres Maximum, Type AO B - L F250, 250 Am peres Maximum, 500 Volts Ac, 1 00,000 Am peres I . C . Page 35 Fuse Plug - I n Co ntacts Fuse Housing U n it Removed Cu rrent Limiting Fuses Page 36 A O B - LF1 00 Fused B reaker Specificatio n : M l L - C - 1 7361 1 5-1 00 Amps. 500 Volts Ac, 60 Cycles. T h ree- Pole. I nterrupting Rating: 1 00,000 A m peres Note: AQB-LF100 breakers are sold for replacement only. They are no longer on Navy Qualified Product List. .c om 8 Tech n ica l Data 29-220 List Prices See Price List 29-020 l nstantaneous Trip Setting i n Amps L(M,� Breaker Complete Breaker FrameCD Trip U nit Style N u m be r ® Style Number National Stock No. Style N u mber Thre e - P o l e 500 Volts Ac Fuses National Stock N o . an Cont. Amp. Rating ua ls A O B - L F 1 00 breakers are desig ned for the same a ppl ication as the AQB-A1 00 ( n o n -fused) circuit breaker except that they may be applied on circuits w here fault cu rrents up to 1 00,000 amps are ava i lable. Breakers desig nated by the suffix " O F" in the table have settings designed for the protection of feeder circu its and those fo l l owed by " D " have higher mag netic settings to a l low for motor starti n g . Style N u m be r ® Quant. R eq . 4 5 2 D 385 G 1 3 452D384 G 1 3 5925-00-849-8481 5925-00-65 5 - 1 1 56 31 3C743H02 31 3C743H02 3 3 4 5 2 D385 G 1 5 452D384 G 1 5 5925-00-65 5 - 1 1 57 5925-00-655 - 1 1 58 3 1 3C743H02 3 1 3C743H02 3 3 5925-00-6 1 7-831 2 5925-00-61 7 - 831 2 452D385 G 1 7 4 5 2 D 384G 1 7 5925-00-65 5 - 1 1 59 5925-00 - 65 5 - 1 1 60 31 3C743H03 3 1 3C743H03 3 3 452D390G02 4 5 2 D 390G02 5925-00-6 1 7 -831 2 5925-00-61 7 - 831 2 452D385G20 4 5 2 D 384G20 5925-00-65 5 - 1 1 61 5925-00-65 5 - 1 1 62 3 1 3C743H03 31 3C743H03 3 3 4 5 2 D 390G02 4 5 2 D 3 90G02 5925-00-61 7-831 2 5925-00 -61 7 - 831 2 452D385G23 4 5 2 D384G23 5925-00-65 5 - 1 1 63 5925-00-65 5 - 1 1 64 3 1 3C743H03 3 1 3C743H03 3 3 90 1 80 1 05 21 0 4 5 2 D391 G 1 6 4 5 2 D 391 G 1 7 452D390G02 4 5 2 D390G02 5925-00-61 7 - 831 2 5925-00-61 7 - 83 1 2 25-DF 25-D 1 80 300 21 0 350 452D391 G 1 8 452D391 G 1 9 452D390G02 452D390G02 5925-00-61 7-831 2 5925-00-61 7-831 2 50 - D F 50-D 300 600 350 700 4 5 2 D391 G20 4 5 2 D 391 G 2 1 4 5 2 D 390G02 452D390G02 75-DF 75-D 450 525 900 1 050 452D391 G 22 452D391 G23 1 00 - D F 1 00 - D 600 700 1 200 1 400 4 5 2 D391 G 24 4 5 2 D 391 G 2 5 ar tM 1 5- D F 1 5- D CD Breaker frame consists of frame with its fuse housing unit and slip type connectors for back connection. but lP does not include trip unit. fuses or mounting blocks. Order these separately. trip units and fuses from table above and mounting blocks from listings below. ® National stock n u m ber not assigned. Description One Stud Assembly Complete with 4 Nuts Terminal M o u nting Block (No Studs) Mounting Block and Stud Set (3 Studs) ca Switc h boa rd M o u nt i n g Breaker frame i n c l udes mounting hardware. Female slip connectors are mou nted on the rear for plugging onto stud projections of term i n a l mou nting block assemblies. Order one for each end of the breaker. Style Number National Stock No. 1 631 442 1 764 240 301 P272G01 5940-00-50 1 -91 20 tri Additions I n d iv i d u a l R e p roductions: When req u i red, reproducti ons of master drawings, outl i n e drawi ngs and certification sheets can be ordered as fol lows : Description 1 2 3 4 Full size photolithic tracing of master drawing on vel l u m Outline a n d d r i l l i n g plan on v e l l u m Certification data o n v e l l u m Reproduction of i t e m s 1 , 2 o r 3 lec Item F u s e H o u s i n g U n it ( N o F uses) Style N umber National Stock No. 31 3C742G01 6605-00-799-3521 N et Weig ht - Lbs. AQB B reaker Complete 3 - Pole AQB Breaker Frame Only Complete with Fuse U n it Assembly Without Fuses Tri p U n it 3 - Pole Fuse U n it Assembly Without Fuses One M o u nting B l ock with 3 Studs C u rrent Limiting Fuse C i rcuit B reaker Handle Locking Device 1 3.62 9.68 2.62 1 .6 2 1 .62 .45 .25 .E D ra w i n g s Ava i lable: Master drawing 900J377; outlin e drilling p l a n and wiring d i agram: 451 0 7 1 1 . H a n d l e Lock ( Fo r S h i p board M a i ntenance Use O n l y ) : Order style n u m ber 1 6 1 4 485. F u n g u s - M o i st u re - R esistant Treatments ( J A N -T-1 52; J A N - C - 1 73 o r M I L- V - 1 73 ) : If specified, contact Westi ng house. External parts are coated; trip u n its are not treated. ww w Tec h n i c a l M a n u a l : NAVS H I PS n u mber 362 - 2 1 66. This booklet per M I L- M - 1 5071 . When required, order B V R -T M -380. Westinghouse E l ectric Corporation Distribution and Control B u s i n es s Unit E lectrical Components Division Pitts b u rg h, Pen nsylva n i a , U . S.A. 1 5220 April 1 991 Tec h n i ca l Data 29-220 Page 37 A Q B - LF250 F u s e d B reaker Specification : M l L- C - 1 7361 on circu its with available fault cu rrents up to 1 00,000 a m ps. O n ly three - pole breakers are avail able. These fused breakers are designed for appli cations similar to those for AQB -A250 ( n on -fused ) . H owever, because of their current limiting fuses, they can be appl ied U n dervoltage release devices, shunt trips and/or auxiliary switches are available for the AO B - L F250 and can be easily installed i n the field. B reaker Com plete Breaker FrameCD Style N u mber Style N u mber tM List Prices See Price List 29-020 Low Those breakers identified by the suffix " L M " i n t h e price table have higher magnetic set tings for motor starting while those carrying the suffix " L" are set for the protecti on of feeder circuits. an 1 25-250 A m ps • 500 Volts Ac, 60 Cycles • T h ree- Pole I nterrupting R at i n g : 1 00,000 Am peres I nstan taneous Trip Setting i n Amps AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Type AO B - LF1 00, 1 00 Amperes Maximum Type AOB - L F250, 250 Amperes M aximum 500 Volts Ac, 1 00,000 Amperes I . C . April 1 991 S u persedes Tec h n i ca l Data 29-220, pages 35-36, dated October 1 978 Mailed to: E, C/29-200A Cont. Amp. Rating .c om 8 Westinghouse Electric Corporation Distri bution a n d Control Busi ness Unit E l ectrical Compo nents Division Pittsburgh, Pennsylvania, U . S .A. 1 5220 Tri p U n i t Style N u mber National Stock N o . High Fuses National Stock No. Style Number® Quant. Req. ar Th ree- Pole 500 Volts Ac ( R efer to West i n g h ouse for Two-Pole Styles and Prices) 6 5 0 1 300 1 500 3000 31 3C748G 1 8 3 1 3C748G 1 9 4520820G02 4520820G02 5925-00-61 7 - 831 3 5925-00-61 7 - 831 3 4520821 G 1 8 4520821 G 1 9 5925-00-65 5 - 1 1 65 5925-00-655 - 1 1 66 3 1 3C743H04 3 1 3C743H04 3 3 1 50 - L 1 50 - L M 6 5 0 1 300 1 500 3000 3 1 3C748G20 31 3C748G21 4520820G02 4520820G02 5925-00 - 6 1 7 -831 3 5925-00-61 7 - 83 1 3 4520821 G20 4520821 G 2 1 5925-00-655 - 1 1 67 5925-00-65 5 - 1 1 68 3 1 3C743H04 3 1 3C743H04 3 3 1 75-L 1 75 - LM 6 5 0 1 300 1 500 3000 3 1 3C748G22 3 1 3C748G23 4 5 2 0820G02 4 5 2 0820G02 5925-00-61 7 - 831 3 5925-00-61 7 - 831 3 4 5 2 0821 G22 4520821 G23 5925-00-65 5 - 1 1 69 5925-00-65 5 - 1 1 70 3 1 3C743H04 3 1 3C743H04 3 3 225-L 225- L M 650 1 300 1 500 3000 3 1 3C748G24 3 1 3C748G25 4520820G02 4 5 2 0 820G02 5925-00-61 7 -831 3 5925-00 - 61 7 -831 3 4520821 G24 4520821 G25 5925-00-655 - 1 1 7 1 5925-00-65 5 - 1 1 72 3 1 3C743H04 3 1 3C743H04 3 3 250 - L 250-LM 6 5 0 1 300 1 500 3000 31 3C748G26 3 1 3C748G27 Net Wt. 32.00 Lbs. ca lP 1 25 - L 1 25 - L M 4520820G02 5925-00-61 7 - 831 3 4520820G02 5923-00-61 7 - 831 3 Net Wt. 24.50 Lbs. 4520821 G26 5925-00-655- 1 1 74 4520821 G27 5925-00-655 - 1 1 73 Net Wt. 3.00 Lbs. 3 31 3C743H04 3 31 3C743H04 Net Wt. 1 .50 Lbs. CD Breaker frame consists of frame with its fuse housing unit and slip type connector for back connection, but does not include trip unit, fuses o r mounting blocks. Order these separately, trip u n its from table above and mounting blocks from listi n g s below. tri ® National stock n u m be r H5925-00-624-3049. Switch board M o u n t i n g Breaker frame i ncludes mou nti ng hardware. Female slip conn ectors a r e mounted o n t h e rear f o r p l u g g i n g onto stud projections o f terminal mounting block assemblies. Order o n e f o r e a c h e n d o f breaker. lec Styl e N u mb er Description One Stud Assembly Complete with 4 Nuts Terminal Mounting Block ( N o Studs) Mounting Block and Stud Set (3 Studs)@ @ Net Weight 3.00 Lbs. 1 63 1 443 3 1 3C68 1 G 0 1 3 1 3 C680G02 I I � National Stock No. 940-00-501 -91 1 9 I t em 1 2 Description Full size photolithic tracing of master drawing on v e l l u m O u t l i n e a n d drill i n g plan on v e l l u m Certification d a t a on vellum Reproduction of items 1, 2 o r 3 w 3 4 .E A d d it i o n s I n d iv i d u a l Reproductions: When req uired, reproductions of master drawings, outline drawings, and certification sheets can be ordered at the following prices: D rawings Ava i l a b l e : Master drawing 900- J - 379; breaker outli ne, drilling and wiring diagram 451 D250. ww H a nd l e Lock ( Fo r s h i pboard m a i ntenance use o n l y ) : Order style n u mber 1 720 1 01 . N et weight . 1 0 lbs. Auxiliary Switch : For description see AOB-A250 breaker, page 31 . Style n u m be r 452D379G02 same as for AOB-A250. Net weight . 1 7 l bs . Shunt Trip Attachment: T o o rd e r refer to AQB-A250 breaker o n page 31 . S t y l e n u m be rs and net prices a re s a m e as those for AQB-A250. Net weight .70 l bs . Undervoltage Device: T o order, refer to AQB A250 breaker on page 3 1 . Style n u m be rs a n d n et prices a re s a m e as those for AQB A250. Net weight 1 . 1 2 l bs. Tec h n i ca l M a n u a l : NAVS H I PS n u mber 362- 2 1 65. This booklet per M I L- M - 1 5071 . When req uired, order B V R -T M - 3 8 1 . Fuse H o u s i n g U n i t ( N o F u ses) Style N umber 452D83 2 G 0 1 National Stock No. Net Weight 4.50 Lbs. O rd e r i n g I n formatio n : See page 4. Net Weig hts : See l istings in tables and additions. .c om Tech nical Data 29-220 Page 38 O u t l i n e D i mensions A O B - L F 1 00 Breakers ua ls Support blocks are nat s u p plied with b reaker, but must b e ordered separately, refer to dwg . I A 4 45 7 all ports n e c e s s a r y to convert a b r e a ker are i nclu ded 5 8 an S l i p C o ntact Asse m b l y Flat washers, lock washers and nuts supplied with terminal m ig. black tM � - 2 0 Mtg screws (capt i vel Front Cover C utout ar Drilling Plan For Mou nting Panel (Rear Connected) 3 Megger holes � lP 1 Dra m eter ca . ' 9 i6- R Mrn. Re move ble fuse b� ly u nit asse m,� - � .E q[a"J_] Re movab le Llil - Mini m u m s l ot C i rcuit B reaker H a n d l e Lock i n g Device lec W i r i n g D i a g ra m Wiring as Shown is for a 3 Pole Breaker For 2 Pole Breaker Omit M iddle Pole tri 9 . 16- R.Mrn. load End Reverse position of lock to prevent breaker f ro m opening ( Not supplied with circuit breaker) trip unit load End w AOB B reaker with Over- C u rrent, S h o rt C i rcuit Trip and Fuses ww Westi nghouse E l ectric Corporation Distribution and Control Bu si ness U n i t Electrical Com ponents Division Pittsburgh, Pennsylva nia, U . S.A. 1 5220 April 1 991 .c om Westinghouse Electric Corporation Distribution a n d Contro l Busi ness U n it E l ectrical Components Division Pittsburg h , Pen nsylva n i a , U . S .A. 1 5220 O u t l i n e D i mensions A Q B - LF250 Breakers Warning , nomeplo te 09B Oia. hole 1 n handle tM ���� AB DE-ION® Circuit Breakers for Naval Shipboard Use an l Page 39 Support b l o c k s ore not supplied wdh b r e a k e r , but must b e o r d e r e d s e p a r te l y r e f e r to d w g 31 3C680. a l l p o r t s n e c e s s a r y to c o n ve r t a b k r ore mcluded Line E n d Frome na m e p a te 29-220 ua ls Types AQB - L F 1 0 0 , 1 00 Amperes Maximum, Types AQ B - L F250, 250 Am peres Maximum 500 Volts Ac, 1 00, 0 0 0 Amperes I . C. April 1 99 1 Su persedes Technical Data 29-220, pages 37-38, dated October 1 978 M a i led to: E , C/29-200A Technical Data 4 Nutsond r-----.+-- su p p l i e d ar f'l I washers w• lh s t u d Load E n d D r i l l i ng Plans For Terminal Mounting B l ocks Flat woshers . l ockwoshers mounting blocks lec and nuts supplied w i t h t e r m i nal tri ca lP Front Sheet D r i l l i ng Template w .E Ty pical Wiring Diagrams Wiring as Shown for 3 Pole Breaker For 2 Pole Breaker Omit M iddle Pole Removable tr�p u n i t ww A Q B Breaker with over cur rent , short Removable ci fuse unit a ss y· '---+"""'---"':...,__j r c u i t t n p and f uses f� � L.H.Side - of breaker ' 13 Bottom ot mig block o f breaker Bottom of breaker It Oio. 6 holes Load End H a n d l e lock i n g Device ( N ot Supplied With Circuit Breaker) When U nder-Voltage Release is Provided � When Shunt Trip and Auxiliary . P rov1. d d . h IS S wrtc A and B au•. swi tch 3 18" lon9 leads l YA YA od s 1 8 " 2 l� e� Shunt t r i p l o ng Note: The a u x . s w i t c h m u s t be u s e d w i t h e a c h shunt t r i p, connect one side of shunt t r i p i n sertes w i t h "A" contact {closed when breaker i s c losed ) of a u x . s w i t c h when connectrng to power supply. .c om Tech nical Data 29-220 Page 40 C h aract e r i s t i c T r i p p i n g C u rves 50 30 20 \ � 5 4 3 2 l l\ I : t� I 5 4 3 2 03 .02 0I 100 30 0 600 N 1 200 1\ \ 500 400 300 200 100 '\� 50 40 30 20 l\ 5 4 3 2 r--2 2 5 Amp r250 Amp . r--- 1 2 5 Amp. r--r- � "0 " "' Ul 8 \\' ��·� 30000 10000 100000 H "' E ,:: 05 0I 3.5 3.0 2.5 2.0 II 7 5 Amp 1.5 50 Amp. 2 5 Amp. * � 1 5 Amp. � 1.0 v ,... - 0.5 0 o Ambient Temperature, OC 10 20 30 40 50 60 70 80 90 100 II I .03 02 I 100 Amp. \ � :: \ \ uu '\ .l. II 1\ \' \ IH " �\ � � 1\\ .\ \ r ��\\ II 5 4 3 2 I 1 I� I 1 7 5 Amp 150 Amp 11 1 1 I I -" Operating Characteristics T h e r m a l Maonetics and Current Lim1ting Fuse 50° A m b i e n t - Cold Start Ac -- Instantaneous Tr i p a t 1 2 0 0 to 1 4 0 0 % Ra t i n g - - Instantan eous Tri p at 600 to 70 0 % Ratmg 100 300 600 1200 Percent Rated Current 3000 30000 100000 10000 lec tri Percent Rated C u r r e n t 1\ 1000 Tri p p i n g Ti me 2 5 Secands! 25% Less T h a n 1 Hour More Than 1 Hour 600 225 1 30 10 � � � \\ 3000 Perc ent of Tnp Element Roling .E E Westingho u se E l ectric Corporation Distribution and Contro l B u s i n es s U n it E l ectrical Components Division Pittsburgh, Pen n sylva nia, U . S.A. 1 5220 ww ,:: � 05 \ � V \ w "' (f) I � A Q B - L F I OO ca I 5000 4000 3000 2000 - - - 1 5 0 0 to 3000 A m p. See Table For Instantaneous Range of Other Tr i p Uni t , \ 10 Tr i pping T1me Operating Characteristics Thermal Magnetic and Current Li m i t i n g Fuse 5 0 ° C Ambient Cold Start Ac Instantaneous Tr i p Range of 2 5 0 Amp. Tr i p U n i t Shown 650 to 1 3 0 0 Amp. � 40 10000 I an 1 00 I tM l\ 500 400 300 200 I 25 Seconds + 2 5 % Less Than I Hour More Than 1 Hour 600 225 1 30 1 000 8 I I ar 5000 4000 3000 2000 � "0 �� /� Per n f Tr i p E l e m e n t Rating lP A Q B - L F 250 10000 To determine the trip unit rating to be used, when the l oad cu rrent and ambient are known, m u ltiply the load c u rrent by the factor obtained from the c urve below for the known ambient. The result will be the ideal trip unit rating. H owever, since trip u n its are furnished only with standard rati ngs as per Navy spec., select the standard unit trip whose rating i s equal to or one rating hig her than the ideal rati ng. ua ls A 0 B - L F 1 00 B reakers A O B - L F250 B reakers April 1 991 .c om Tech nical Data Westinghouse Electric Corporation Distribution and Control B u s i n ess U n it E lectrical Com ponents Division Pittsb u rg h , Pennsylva n i a , U . S.A. 1 5220 Types AQB-L4000F, AOB-L4000M ; 1 50,000 Amperes I.C. a n d AQB-LL400QS; 1 00,000 Am peres I . C . 250-400 Amperes; 500 Volts 60 Hz Ac Page 41 AB DE-ION® Circuit Breakers for Shipboard Use ua ls April 1 99 1 New I nformati o n Mai led to : E , C/29-200A 29-220 an Description The Navy Type AQB-L4000F, AQB-L4000M, and AOB-LL400QS m o l ded case ci rcu it breakers a re 500 Vac m a xi m u m rated devices with electronic trip u n its rated at 400 a m peres m a x i m u m conti n u o u s cu rrent at 60 Hz. The ci rcu it breakers are assembled as 3-pole u n its which may be used as 2- or 3-pole devices. tri ca lP ar tM The c i rcuit breakers a re designed to M I L-C1 7361 and meet the req u i re ments of Class HI-shock, M I L-S-90 1 . The c i rc u it breaker electronic trip u n it has adj u stable short delay time a n d pick- u p trip sett i n g s which can be read i l y changed at the operator level to meet the s h i p bo a rd system trip req u i re ments. Four i nterchangeable rati ng-plugs a re ava i l a b l e to sel ect the conti n u o u s cu r rent rating of 250, 300, 350 or 400 a m peres. Also provided i s a non-adjusta b l e i nverse time delay tripping action for ove rload co n ditions, and i n stantaneous tripping for pro tection against short circ u it conditions that exceed the preset s h o rt delay pick-up set t i n g . In open a i r at 50°C, the c i rc u it breaker will carry conti n uously a cu rrent eq u a l to the a m pere rati ng of the i n sta l l ed rating plug. The ca l i bration of the trip unit is i n sensitive to a m bi ent tem peratures over a range of - 20oc to + 70°C. .E lec AQB-L400QF, AOB-L400QM a n d AOB LL400QS cu rrent l i m iting circ u it breakers are desi g n ed for i n stallation i n switchboards for protection of gen erators a n d feeders and branch circu its with ava i l a b l e fault cu rrents of 1 50,000 a m peres m a x i m u m . Operation The AQB-L400QF, AQB-L4000M , a n d AOB LL4000S cu rrent l i m it i n g c i rc u it breakers (without the need for cu rrent l i m iting fuses) a re desi g n ed to provide c i rc u it protection for low voltage d i stribution systems. The ci rcuit breakers will di scon nect a load from a n electrical supply when the h a n d l e is operated, when a n overcurrent o r s h o rt c i r- 250-400 Amperes, 500 Volts Ac, 60 Hz 3 Pole Only, 50°C Ambient Protective Functions: Short Delay Pick-up (Adjustable) AQB-L4000F AQB-L4000M AOB-LL4000S Continuous Current Ratings: 350A 250A 400A 300A Long Delay Pick-up (Minimum Thermal Trip) (Fixed) 1 3 1 % to 1 56% (All Rati ngs) ww w AQB- L4000F, AOB-L4000M a n d AOB LL4000S Current L i m iting Navy Circuit Breakers Current Interruption Ratings: AQB-L4000F 1 50,000 Amperes AQB-L4000M 1 50,000 Amperes AOB-LL400QS 1 00,000 Amperes 650-1 500 Amps 1 700-3200 Amps 3600-5800 Amps Instantaneous Pick-up (Fixed) 2850 Amps AOB-L4000F 3280 Amps AQB-L4000M 6300 Amps AOB-LL4000S Motor Operator Mounted on Circuit Breaker cuit condition develops, or when the push to-trip button i n the trip u n it i s m a n u a l l y pressed. A complete breaker consists of a breaker, rat i n g p l u g p l u s mounting base a n d is ava i l a b l e w i t h n u merous attach ments such as e l ectrical operator, s h u nt trip, u n dervoltage release a n d a u x i l i a ry switches to perform varied a u x i l i a r y fu nctions. The c i rcuit breaker has a spri ng-loaded i n dependent over-togg l e operating mech anism that provides q u ick-make q u i ck-break trip free operati o n . T h e operating mech a n i s m a l so provides t h e electro-mec h a n ical m e a n s t o o p e n the con tacts when trip conditions occur. When c u r rent is flowing through the contacts of the circuit breaker, the positions of the lower contact arms and the moving contact arms i nduce opposing m a g netic fields. The result ing opposi ng forces a l o n g the m a g netic fl u x l i nes cause rapid contact blow-a p a rt u n d e r h i g h cu rrent fault co nditions. The AQB L400QF and AQB-L400QM ci rcuit breakers have s l ot motors for each moving contact a rm to intens ify the mag netic field a n d f u r ther i ncrease the blow-a part effect. .c om Technical Data 29-220 Page 42 This enables these circuit breakers to have an i nterrupti ng rating of 1 50 kA compared with the AQB-LL400QS rating of 1 00 kA. the trip u n it i n itiates a trip after the sel ected s h o rt delay time sett i n g . \ \ List Prices See Price List 29-020 Type Breaker Circuit Breaker, Navy Type (Supplied with male plug-in adapters installed for rear connection) AOB-LL4000S Circuit Breaker AOB-L4000F Circuit Breaker AOB-L4000M Circuit Breaker Magnetic Field With Slot Motor 1 230C84G01 1 230C84G02 1 230C84G03 1 230C84G04 Type Motor Operator 1 1 5 V Ac Motor Operator 450/1 1 5 V Ac Westinghouse Style N umber 1 234C53G01 1 234C53G03 lec tri ca lP ar A push-to-trip button is provided to m a n u a l l y trip the ci rcuit b reaker. When the but ton is pressed, a p l u nger rotates the latch lever causing the c i rc u it breaker to trip. All trip u n its are b u i lt i nto the c i rc u it breaker fra mes and use e l ectro n i c sensing e l e ments. The Type AQB-L400QF, AOB-L4000M, and AOB-LL400QS Seltron ic@l trip u n its provide protection functi ons. All trip u n its a re s u p plied e l ectrica l l y from cu rrent sensors mou nted on the m a i n cond uctors in the c i r cuit breaker base. A field-installed rating plug determ i nes the conti n u o u s a m pere rat i n g of the trip u n it. An e l ectrical i nterlock causes the c i rc u it breaker to trip at cu rrent leve l s of 75% o r m o re i f the rating plug is not i nsta l led. U nder fa u l t conditions, the trip unit w i l l i n itiate a trip signal and en ergize the flux shunt trip. When the flux s h u nt trip operates, a p l u nger extends and rotates the trip lever. As the trip lever rotates, the latch lever rotates which u n latches the trigger a n d the c i rc u it breaker trips. 1 230C83G01 1 230C83G02 1 230C83G03 tM Rating Plug 2500 Rating Plug, 250 Amps 3000 Rating Plug, 300 Amps 3500 Rating Plug, 350 Amps 4000 Rating Plug, 400 Amps Westinghouse Style Number an \ ua ls Instantaneous Trip F o r short ci rcuit condi tions that exceed the i n sta nta neous (over ride) pick-u p value, but not the current l i m iting t h res h o l d ( F i g u res 2-3 through 2-14) the trip unit i n itiates a trip with n o i nten tional delay. Motor Operator The motor operator is designed to remote l y switch a ci rcuit breaker to i t s O N , O F F a n d relatch positions. The relatch function w i l l occur automatically after a c i rc u it breaker trip operati o n . The m otor operato r i s self conta i ned and assem bled in its own m o u nt i ng fra m e which mou nts on t h e front of the ci rcuit breaker. W h e n the O N o r OFF remote control button is pressed, cu rrent flows to the e l ectric moto r which turns a b a l l bea r i n g and screw assem b l y d riving the c a r r i e r a n d r o l l e r assembly. Two rol l e rs f i t over the c i r cuit breaker h a n d l e a n d m ove with the h a n d l e through i t s r a n g e of moveme nt. Limit switches control the travel of the carrier assembly. A term i n a l block is provided in t h e m o u nting frame for contro l connecti o n s . .E Overload Trip The trip u n it i n itiates a n u lti mate trip of the ci rcuit breaker wit h i n one h o u r for a n ove rload of 1 3 1 % to 1 56%, a n d i n l e s s time f o r h i g h e r ove rloads. Short Delay Trip For s h o rt ci rcuit conditions that exceed the s h o rt delay pick-up setting but not the i n stantaneous (override) pick-up, Circuit Breakers, Navy Type, AQB-L400QF, AQB-L400QM, and AQB-LL400QS and Motor Operator ww w Westingh ouse E l ectric Corporation Distri bution and Control Busi ness U n it E l ectrical Com ponents Division Pitts b u rg h , Pennsylva n i a , U . S .A. 1 5220 April 1 99 1 .c om Technical Data Westinghouse Electric Corporation Distribution a n d Control Business Unit E l ectrical Components Division Pittsburgh, Pennsylva nia, U . S.A. 1 5220 April 1 99 1 N e w I nformati o n M a i led to: E, C/29-200A Mounting Block Type Westinghouse Style Number 1 230C83G 1 5 Switchboard Mounting Breaker fra me incl udes mounting h a rdware. Stud projections a re mou nted o n the rea r of the breaker for p l u g g i n g i nto fe m a l e s l i p co n nectors of ter m i n a l mou nting b l ock asse m blies. 1 230C83G16 Handle Lock ( Fo r s h i pboard m a i ntena nce use o n l y ) order style n u m be r 1 720 1 0 1 . Mounting Block, Molded Base Only (For mounting a front connected circuit breaker, or as a replacement part) 1 230C81 G05 AOB-L4000F with 1 1 5 V Ac Undervoltage Release Mechanism Male Slip Connectors (Replacement part, three per kit) 1 230C81 G04 AOB-L4000F with 1 20 V De Undervoltage Release Mechanism 1 230C83G17 Front Connected Terminal (Required three per line or load end) 504C497G01 AQB-L4000F with 250 V De Undervoltage Release Mechanism 1 230C83G 1 8 AOB-L4000M with 1 1 5 V Ac Undervoltage Release Mechanism 1 230C83G 1 9 AOB-L4000M with 450 V Ac* Undervoltage Release Mechanism 1 230C83G20 AOB-L4000M with 1 20 V De Undervoltage Release Mechanism 1 230C83G21 AQB-L4000M with 250 V De Undervoltage Release Mechanism 1 230C83G22 AOB-L4000S with 1 1 5 V Ac Undervoltage Release Mechanism 1 230C83G 1 1 AQB-L4000S with 450 V Ac* Undervoltage Release Mechanism 1 230C83G 1 2 1 230C83G 1 3 1220C86G08 AQB-L4000S with 1 20 V De Undervoltage Release Mechanism 1 220C86G09 AOB-L4000S with 250 V De Undervoltage Release Mechanism 1 230C83G14 1 220C86G01 1 220C86G02 1220C86G05 1 220C86G06 1 220C86G07 Shunt Trip Type 1 220C86G03 1 220C86G04 lec Combination Shunt T r i p and 1 a/1b Auxiliary Switch (LeftPole Only) tri Westinghouse Style N u m ber Shunt Trip (Left-Pole only) (Includes built-in cutoff switch) 1 1 5 V Ac/28 to 1 20 V De 450 V Ac Only ww w .E 1 1 5 V Ac/28-1 20 V De Shunt Trip and 1 1 5-450 V Ac Auxiliary Switch 1 1 5 V Ac/28-1 20 V De Shunt Trip and 1 20 V De Auxiliary Switch 450 V Ac Shunt Trip and 1 1 5-450 V Ac Auxiliary Switch 450 V Ac Shunt Trip and 1 20 V De Auxiliary Switch ar Auxiliary Switch 1 a/1b 1 1 5-450 V Ac 2a/2b 1 1 5-450 V Ac 1 a/1b 1 20 V De 2a/2b 1 20 V De 1 a/1b 1 1 5-450 V Ac and 1 a/1 b 120 V De Combination lP Westinghouse Style Number ca Type tM AOB-L4000F with 450 V Ac* Undervoltage Release Mechanism 1 220C86G 1 0 1 220C86G1 1 an Type Auxiliary Switches AB DE-ION® Circuit Breakers for Naval Shipboard Use Undervoltage Release ( Left-Pole Only) UVR and Circuit Breaker m ust be ordered as a n i nteg ral u n it Westi nghouse Style Number 1 230C81 G01 Plug-in Mounting B lock, Rear Connected, Complete (Required one per load or l i ne end) Page 43 ua ls Types AQB-L4000F, AQB-L4000M ; 1 50,000 Amperes I.C. a n d AQB-LL4000 S ; 1 00,000 Am peres I . C . 250-400 Amperes; 500 Volts 60 Hz Ac 29-220 Fungus - Moisture - Resistance Treatments: (JAN-T- 1 52; JAN-C- 1 73; M I L-V- 1 73) If specified contact Westing house. Exte rnal parts are coated. Technical Manual : When req u i red order 1 240C33H 0 1 . Portable Test Kit - Can b e used t o functiona l ly test the breaker for overload and s h o rt circuit, w h i l e breaker is m o u nted. When req u i red order catalog n u mber STK2. Individual Reproduction : When req u i red reproduction of outl i n e d rawings and certification sh eets can be ordered a s follows: Item 1 2 3 Description Outline drawing and dril ling plan on vellum Certification data on vellum Reproduction of items 1 and 2 Repair Parts: Net Weight: *Using externally-mounted step-down transformer supplied Item Circuit Breaker Motor Operator Mounting Block Front Connected Terminals (Set of Three) Portable Test Kit Weight 30 lbs. 22 lbs. 1 0 lbs. 1 lb.- 1 0% ozs. 12 lb.-14% ozs. .c om Tech nical Data 29-220 w .E lec tri ca lP ar tM an ua ls Page 44 ww Westi n g h o use E l ectric Corporation Distribution and Contro l Busi ness U n it E l ectrical Compon ents Division Pittsbu rg h , Penn sylv a n i a , U .S .A . 1 5220 April 1 99 1 April 1 99 1 New Information M a i led to : E, C/29-200A • • AB DE-ION® Circuit Breakers for Naval Shipboard Use Navy Type AQB-L4000F Circuit Breaker : . "' Rating Plug: 3000 ar tM Rating Plug: 2500 Curve Tolerance Applies Over Temperature Range of - 20 De g. C. to + 70 Deg. C. Page 45 an Navy Type AOB-L400QF Circuit Breaker 29-220 ua ls Types AOB-L400QF, AQB- L4000M ; 1 50,000 Amperes I.C. a n d AOB-LL4000S; 1 00,000 Am peres I .C . 250-400 Amperes; 500 Volts 6 0 Hz Ac .c om Technical Data Westinghouse Electric Corporation Distribution and Control B u si n ess U n it E l ectrical Compon ents Division Pittsburgh, Pennsylva n i a , U . S.A. 1 5220 · - · --- - lP - l l Short Deldv Pwk Up - � � . -- f .E lec tri ca Hc-,......J+�,-c__,-,_,-,..,. 1650 AI low S<ettlrHj ��__,-c-t',..,..,.,... 1 1 500 A1 H1qh Sett,ng ww w Time-Current Curves for AOB-LL4000S Circuit Breaker with 250 Ampere Rating Plug Time-Current Curves for AOB-LL400QS Circuit Breaker with 300 Ampere Rating Plug oc < z ', .c om Tec h n ical Data 29-220 Page 46 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. • Mm,rnum Tr�p an Over Temperature Range of - 20 Deg. C. to + 70 Oeg. C. ' ·- - z , -� \u Short Delay ur · · · � -E · ·- ;;:: ar -c-:-:-==- 1650 AI Low Senmg �---cc-c��_,-,- l l � O O A i H 1 g h Se!t1r1g . -�- tM · C i rcuit Breaker Rating Plug: 4000 Rating Plug: 3500 Curve Tolerance Applies I; Navy Type AOB-L4000F ua ls • • lP Short Delay T1me lec tri ca MAX Time-Current Curves for AQB-LL400QS Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AQB-LL400QS Circuit Breaker with 350 Ampere Rating Plug ww w Westing house E lectric Corporation Distribution a n d Control B u si n ess U n it E l ectrical Com ponents Division Pittsburgh, Pennsylva n i a , U . S .A. 1 5220 April 1 991 April 1 99 1 N e w Informati on M a i led to: E, C/29-200A • • tM Rating Plug: 2500 AB DE-ION® Circuit Breakers for Naval Shipboard Use ICl Navy Type AQB-L400QM Circuit Breaker Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. ar Curve Tolerance Applies Over Temperature Range of - 20 De g. C. to + 70 Deg. C. Page 47 an Navy Type AQB-L400QM Circuit Breaker 29-220 ua ls Types AQB-L4000F, AOB-L400QM ; 1 50,000 Amperes I . C . a n d AOB-LL400QS; 1 00,000 Amperes I.C. 250-400 Amperes; 500 Volts 60 Hz Ac .c om Technical Data Westinghouse Electric Corporation Distribution a n d Control B u s i n ess U n it E l ectrical Compon ents Division Pittsbu r g h , Pennsylva n i a , U . S.A. 1 5220 - ---- < - -�-z · - -,o ; lP �- Curren1 L 1 m lt1ng Threshold ·---- + t - +-� 1·1 =t=:-:= .E lec tri ca ' ___,__l . \ w Time-Current Curves for AQB-L400QF Circuit Breaker with 250 Ampere ww Rating Plug • --� t • �-· t • D(Jl •i� i OD? , · ___ ll Time-Current Curves for AQB-L400QF Circuit Breaker with 300 Ampere Rating Plug I 00 .c om Technical Data 29-220 Page 48 • Navy Type AQB-L400QM Circuit Breaker c- : JOOU > Rating Plug: 3500 Navy Type AOB-L400QM Circuit Breaker ua ls • Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. �- M1n , Sl1ort '---+--r-:.:_:_;_:_:_;_ 1 1 700 A1 13200 AI < -z P·rk Up · --- . Sf'tr1ng H1gh Sett1ng lec tri ca lP ar tM < , an Curve Tolerance Applies Over Temperature Range of -20 Deg. C. to + 70 Deg. C. il Time-Current Curves for AOB-l400QM Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AOB-l400QM Circuit Breaker with 350 Ampere Rating Plug OGI ww w Westinghouse E l ectric Corpo ration Distribution and Control B u si ness U n it E lectrical Components Division Pittsburgh, Pennsylva n i a , U .S.A. 1 5220 April 1 991 .c om 8 Technical Data Westinghouse Electric Corporation Distri bution a n d Control B u s i n ess U n it E l ectrical Com ponents Division Pittsburgh, Pennsylvania, U .S.A. 1 5220 April 1 99 1 N e w I nfo rmation M a i led to: E, C/29-200A 29-220 Page 49 AB DE-ION® Circuit Breakers for Naval Shipboard Use • • tM ar Curve Tolerance Applies Over Temperature Range of - 20 Oeg. C. to + 70 Deg. C. Navy Type AOB-l4000S Circuit Breaker an Navy Type AOB-l4000S Circuit Breaker ua ls Types AQB-L400, AOB-LL400 500 Volts Ac 400 Amperes M ax i m u m , 1 50,000, 1 00,000 Amperes I . C . , Respectively � < � -Mm1rnu m _ '>0 - Tr�p T1me__: _ __ _ : : : : :: Rating Plug: 3000 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Oeg. C. - -�--+ + - - , . · -+- ca :- ; ::::: ; .E lec t--+---+---- ww w Time-Current Curves for AOB-L4000M Circuit Breaker with 250 Ampere Rating Plug ;;:: �---==--:___: ; : ;--- � tri ) l: E " ::::: lP - --- -----�------>---+- - ' Time-Current Curves for AOB-L4000M Circuit Breaker with 300 Ampere Rating Plug .c om Technical Data 29-220 Page 50 • Navy Type AQB-L400QS Circuit Breaker Navy Type AGB-L400QS Circuit Breaker ua ls • Rating Plug: 4000 Rating Plug: 3500 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. -+ t +-- · · · �- lec I I tri ca lP , J ,_ · ·- +-� � ____(_ . . --+------- < .�-� - L • _____,__. 00 ':: ar tM an Curve Tolerance Applies Over Temperature Range of - 2 0 Deg. C. to + 70 Deg. C. � J, ' -�- � -- --- .. -- - · · · · + ---+ Short Delay T 1 m e - �- - -+-------r--� . : ��S:tt·,n:--� - .; m��� Time-Current Curves for AQB-L400QF Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AQB-L400QF Circuit Breaker with 350 Ampere Rating Plug ww w Westi nghouse E l ectric Corpo rati on Distri bution a n d Control Business U n it E l ectrical Compon ents Division Pittsburgh, Pennsylva n i a , U .S.A. 1 5220 April 1 99 1 .c om Westinghouse Electric Corporation Distribution a n d Control B u s i n ess U n it E l ectrical Compon ents Division Pittsburgh, Pen nsylvania, U . S.A. 1 5220 Apri l 1 99 1 New Information M a i led to: E, C/29-200A Tech n ical Data 29-220 Page 51 Types AOB-L400, AQB-LL400 500 Volts Ac 400 Am peres M a x i m u m , 1 50,000, 1 00,000 Amperes I . C., Respectively ua ls Outline Dimension AQB-L400, AQB-LL400 AB DE-ION® Circuit Breakers for Naval Shipboard Use ,.___ 6 1f16 4718 -.,.1 718 ---- 4'116- II . tM Automatic Tripped ww w .E lec tri ca lP ar 181/1 6 16 ' 51;. "'] �3'18 an I - r·,] i I IH---H+'ih Front Surface of Mounting Panel ],I '' II Load Dimensions i n I nches *Conductor Height for Front Connection Center Line of Circuit Breaker Handle 29-220 Page 52 r------ 1 01/a 1. 1713116 Outline AQB-L400, AQB-LL400 with Motor Operator 1013116 1 1 '132 @ I @ I I I 16 .--- 0 0 627132 �- �( @ Reset 8 8 �� Load End Dimensions in Inches w .E lec tri ca - 8 ---- ar 513116 0 tM Auto Trip -.- lP 81116 @ Line End ua ls @ )� an /" l .c om Technical Data ww Westinghouse E l ectric Corpo ration Distribution and Control B u si n ess Unit E l ectrical Components Division Pittsburgh, Pennsylva n i a , U .S.A. 1 5220 April 1 991 .c om Cl Tech n ical Data Westinghouse Electric Corporation Distri bution a n d Contro l B u s i n ess U n i t E lectrical Components Division Pittsbu rgh, Pennsylva n i a , U . S .A. 1 5220 Types AQB-L400, AQB-LL400 500 Volts Ac 400 Amperes M a x i m u m , 1 50,000, 1 00,000 Amperes I.C., Respectively Wiring Diagrams Front Sheet Template AB DE-ION® Circuit Breakers for Naval Shipboard Use 1 I Ll tM <i Handle Load v 5.500 .L ar (" 1.625 lP For 2 Pole Breakers Use Two Outside Poles � 1 .969 �[;:7- . 1 88 R -------l-�1 ca ('!"\ l 7.000 3.500 tri Drilling Plan for Mounting Panel 2 2.078 - ,.______ 6.0 1 6 .31 2 Dia. Megger Holes '-V ' .250 R 3.250 AQB Breaker With Overcurrent and Short Circuit Trip Protection / 5. 1 88 an Line Page 53 ua ls Apri l 1 99 1 New Information M a i led to : E , C/29-200A 29-220 lec 1-+------ 1 7.000 --------.1 �------ 14.750 --------.; .E f+---- 9.562 -----.-+-- Line End ww w .500 Dia. - 6 Holes for .375 Mtg. Bolts 1 . 1 99 R 5.500 Load End .c om Tech nical Data 29-220 .E lec tri ca lP ar tM an ua ls Page 54 ww w Westing house E l ectric Corporati o n Distri bution a n d Control Busi ness U n it E l ectrical Co m po n ents Division Pittsburgh, Pen nsylva nia, U . S.A. 1 5220 April 1 99 1 .c om Tec h n i ca l Data Westinghouse Electric Corporation Distribution a n d Control B u s i n ess U n it E l ectrical Compo nents Division Pitts burgh, Pennsylvania, U . S .A. 1 5220 Types A O B - A 1 6 0 1 , N O B -A 1 60 1 5 0 0 - 1 600 Am peres; 5 0 0 Volts, 60 H z Ac, 75,000 Amperes I . C. Page 55 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls April 1 99 1 Su persedes Tec h n ical Data 29-220, pages 39-40, dated August 1 98 1 a n d S u pplement to Technical Data 29-220, page . 0 1 , dated May 1 4, 1 979 M a i led to : E, C/29-200A 29-220 A Q B -A1 601 a n d N Q B - A 1 601 N avy B reakers lP ar tM an Note: AQB-A1601 are sold for replace ment only. They are no longer on the Navy Qualified Products List. I tri Continuous Instantaneous 1 Breaker Only, consists o f : ---� Trip Setting Ampere Frame { I ncludes Stab s ) A-c Amperes Rating National Style Low High Stock Number N umber Trip U n it Style Number lec Type ca List Prices See Price List 29-020 3 Pole, 500 Volts, 60 Cycles A-c Trip u n its for these breakers have an adjust able instantaneous trip and are listed with and without delayed instantaneous trip for system coord i nation. National Stock Number N QB -A1 601 Breakers have a continuous rating of 1 60 0 amperes. They are used only as discon nects since they do not have an automatic trip device. Without Delayed Instantaneous Trip 2000 4000 2000 2000 2000 4000 4000 6000 1 2000 6000 6000 6000 1 2000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 .E AQB 600X AQB 600XM AQB 800X AQB 1 OOOX AQB 1 200X AQB 1 400X AQB 1 600X NOB 1 600 3720523G01 3720523G03 3720523G07 3720524G03 3720524G05 3720524G07 3720524G09 3720524G 1 0 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 . . . . . . . . 5925-00-406-61 3 1 With Delayed Instantaneous T r i p (XT1 - M i n . T i m e Delay .041 7 - .0458 Sec.) AQB AQB AQB AQB AQB 500XT1 800XT1 1 000XT1 1 200XT1 1 600XT1 2000 2000 2000 2000 4000 6000 6000 6000 6000 1 2000 1 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 1 374021 1 G01 374021 1 G07 374021 2G03 374021 2G05 37402 12G09 . . . . . . . . 5925-00-1 02-6086 5925-00-727-757 4 w With Delayed Instantaneous Trip (XT2 - Max. Time Delay .0708 - .0750 Sec.) ww AOB 500XT2 AQB 800XT2 AQB 1 200XT2 AQB 1 600XT2 2000 2000 2000 4000 6000 6000 6000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 3740221 G01 3740221 G07 3740222G05 3740222G09 A O B - A 1 60 1 circuit breakers are designed for i n sta l l ation i n switchboards for protec tion of ge nerators and feeder and branch circuits. A complete breaker consists of a breaker plus mounting base a nd is available with n u mer ous attachm ents such as electrical operator, shunt trip, undervoltage release and auxil iary switches to perform varied auxiliary func tions. Complete Breaker Breaker Only 500-1 600 A m peres, 500 Volts A - c, 60 Cycles O n ly, 3- Pole, 50°C A m b i e nt I nterrupting R a t i n g : 75,000 A m ps. A - c (Without D e layed I n sta ntaneous} 50.000 A m ps. A - c (With D elayed I nsta nta neous} S pecificat i o n : M I L- C -1 7361 Class : Hi S h ock M I L-S-901 V i b rat i o n : M I L - S T D - 1 67 M aterial and Workma n s h i p : M I L- E -91 7 5925-00-727-7555 5925-00-1 03-4248 Note : B reakers with rati ngs other than those l i sted above are considered as special and full descriptive data must be provided. 400 cyc l e b reakers are not ava i l a b l e . Page 56 Mounting BaseCD N et Wei g hts Optional AdditionsCD Description ua ls Shunt Trip @ : Mounts i n right pole only. Has m o m entary rati ng only; coil leads m u st be w i red in series with 1 A contact of a u x i l i a ry switch. .c om Tec h n ical Data 29-220 Undervoltage Release @ : M o u nts i n right pole only. Electrical Operator, 1 1 5 Volt Electrical O perator, 450 Volt Shunt Trip U ndervoltage Release Auxil iary Switch Cable Con nector an Auxiliary Switch: M o u nts i n left pol e only. 4 contacts, a ny co mbi nation of A's a n d B's, (supplied as 2A a n d 2B u n l es s spec ified) 8 co ntacts, a ny combi nation of A's and B's, (su ppl ied a s 4A a n d 4B u n l es s s pecified) Breaker Only AOB NOB Breaker Frame (AOB and N O B ) Trip U n it AOB NOB Mounting Elase Only For switchboard mounting. Inc ludes back connectors for switch board bus and male stabs to engage breaker. M atc hing stabs are supplied with breaker frame. Cable Con nector: M o u nts to bus con n ector fo r cable co n nection. Each lug accepts four cables, 600 M C M m a x . 1 l u g requi red per bus connector. Sty l e N u m be r : 505C706G03 1 51 1 48 1 28 23 20 75 27 35 % 1 Y.. 1% 3 O rd e r i n g I nformation When ordering Westingh ouse N avy circuit breakers consult the check list below to make sure you have provided correct infor mation. You should specify: ar Style N u mber: 373D307G02 tM Automatic Reset Switch For use with m otor operator w h e n an auto matic reset function is req u i red. Factory i n stalled only. Weig ht, Lbs. 1 . Quantity, West i n g h o use style n u m b e r a n d N a t i o n a l stock n u m b e r of: Fungus, Mo isture Resistant Treatment: (a) B reaker frame and trip u n it. (JAN-C- 1 73 or M I L-V- 1 7 3) : If specified, con ( b ) M o u nting base. tact West i ng h ouse. External parts are coated; (c) Spare breakers or trip units. ( Usually trip un its a re not treated. one required for each ten u n its or Drawings fraction thereof of each current rating.) M a ster p l a n : 900J442 (d) I nstruction books. S heet 1 o f 4 : Breaker Only and W i r i n g d i a grams 2. S h i pment S h eet 2 o f 4 : Trip U n it, Curves and Attach Specify transportation mea ns, method of ments packaging and preservation and req uired S h eet 3 of 4: M o u nt i ng Base and Cable shipping date. Conn ectors S heet 4 of 4: Motor O p e rator 3 . D rawings Specify quantity of outline or master plan Individual Reproductions: When req u i red, drawings required. reproduct i on s of sheets 1 t h r u 4 of m a ster plan 900J442 can be ordered as fol l ows: 4. Inspection T y p e R e p roduction I n d i cate whet h e r Government S o u rce Vellum inspection is req u i red at factory prior to Prints (Paper) shipment. .E lec tri ca lP Electrical OperatorCD Technical Ma nua l : NAVS H I PS No. 0962-0 1 45000. This booklet per M I L- M - 1 507 1 . When req u i red, order BVR-TM-576. M ou nts to front of breaker for remote opera tion. 450 volt Ac rat i n g uti l izes a tra nsfo rmer Dimensions: Pages 53, 54, 55. i n conj u n ction with a 1 20 volt m otor. If auto matic reset is desired, order the ci rcuit Characteristic Curves: Pages 56, 57. breaker with optional Automatic Reset Switch (See Optional Additions) CD Can be field mounted. w Rating ww 1 20 V A-c 450 V A-c Style Number National Stock N u m be r 1 37 1 D38G06 1371 D38G08 None Assi g n ed ® Breaker can be supplied with either shunt trip or undervoltage release, but not both. Westi nghouse E l ectric Corporation Distribution a n d Control Business U n it E lectrical Compo nents Division Pittsburgh, Pen nsylva n i a , U . S .A. 1 5220 Apri1 1 991 Technical Data .c om 29-220 Westinghouse Electric Corporation Distribution a n d Control Busi ness U n it Electrical Components Division Pitts b u rg h , Pennsy lv a n i a , U . S .A. 1 5220 Page 57 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Types AQB-A1 601 , N Q B - A1 601 500 - 1 600 Amperes; 500 Volts, 6 0 Hz. Ac. 75,000 Amperes I . C . April 1 99 1 Su persedes Technical Data 29-220, pages 41 -42, dated October 1 978 Mailed to: E, C/29-200A AOB a n d N O B C i rcuit B reaker Frame O u t l i n e D i mensions N O B-Same except for tnp u n it nameplate. F ront Panel Cutout an <t of Breaker Top End of Breaker ar tM 2 !!, / 3Z., T 7� 32 1-+----+- Removable Handle Extension Supplied lec tri ca lP wrth Breaker Furnrshed wrth a l I Breakers f o r Manual Closmg and Opening � Drameter 3 Megger Holes When u ndervo ltage release and auxil iary switches are provided �-- Wiring D i a g ra m s -�---t----t----; 1��;S;- � ) ) : .E AQB NOB r Tt) \ c r) r) r Line L i ne 4"A" , r 1·. 1 1 1 1 ct1jJ ctjjJ w , ww Load Sw•tches 1 6 Leads 18 Inches , ' L - - - - - - - - - - - - - '* Long Load 900J442 Sheet ) ���\ � , : ;_ �- - - - - - - - - - - - - Reproduced From Drawing d ' ' 1 of 4 __ _ -- _ _ _ -· When shunt trip and auxi l i a ry switch are provided - ' \:_{._ _ _ _ _ _ _ _ _ _ _ _ _ , 1 ; -� Sw1tches 2 Leads 18 Inches Long = \ , : �: : . I�� J � lli l�"' Long Under voltage Release )) :��:·:��� � -r -r r- -- ' �: e 18 ln h s ' I ' Lang J"· Note · The a u x i l i ary sw1tch must be used with each shunt trip. Con nect one side of shunt trip in series with "A" contact (c losed when breaker is c losed) of a u x i l i ary switch when connecting to power supply. .c om Technical Data 29-220 Page 58 M o u nt i n g Base O u t l i ne D i mensions an ua ls T o p View 1------ 12� ------i Side View � 010 8 Holes ( Mounting Bas e ) S w , t c h boord Mountmg A n g l e I ca lP ar --------1 tM 0 0 0 14� 3 �-1 6 T a p 4 Holes ( Breaker Mou n t 1 n g ) lec tri Load Cutout F ro n t Panel Cutout ww w .E For Switchboard Back Panel Reproduced From Drawing <t_ of Breaker 4 1 f � t M o u nting Base W1th cable connectors style 505C706G03 lug capacity-four 600 M C M cables per l u g T o p End of Breaker z!l/ 32 f Outl1ne of Mou n t 1 n g Base 900J442 Sheet 3 of 4 April 1 991 .c om Tech nical Data 29-220 Westinghouse Electric Corporation Distri bution a n d Control B u s i n ess U n it E l ectrical Com ponents Division Pittsbu rg h , Pennsylva n i a , U . S .A. 1 5220 ua ls Electrical Operator Outline (Di mensions in Inc hes) tM + ar D 0 Removable H a n d l e 0 Used for Manual Operation O n l y 0 lP 22 �<= 6 an 1- 0 AB DE-ION® Circuit Breakers for Naval Shipboard Use Types AQB-A1 601 , N O B - A 1 601 500- 1 600 Amperes; 500 Volts, 60 H z . Ac, 7 5,000 Am peres I . C . April 1 99 1 Su persedes Tec h n i ca l Data 29-220, pages 43-44, dated August 1 981 M a i led to: E, C/29-200A Line End Page 59 AOB -A 1 60 1 Breaker Wiring D iagrams For 1 20 Volt Ac Electric a l Operator Limit Switches ca Load End For 450 Volt Ac E l ectric a l Operator l(2;)�=-::====;-�:;;::::-; tri LS1 NC lec Ter m i n a l B l ocks Control Device M u st Have N o n - M a i ntained Type Contacts S u p p l ied by Customer .E Switchboard Door Cutout For E lectric a l ly Operated Breaker '/2 M o u nt i ng Holes for Mounting Base --r� Cutout Nominal Voltage Style Voltage Range N u mber 1 20 Volts Ac 450 Volts Ac CD Captive Screw 3j, s - 3 2 Tap (2) Holes Reproduced From Drawing Electrical Operator •;32 D i a meter H o l e · w ww Gasketed Cover For Switc h board Door Cutout (Gasket Ceme nted to Cover ) Control Device M ust Have N o n - M a i n t a i ned Type Contacts Supplied by Customer 1 371 046 CD 90- 1 30 1 37 1 D38G01 360-500 1 3 7 1 D38G03 A Transformer i s Provided i n The Operator Frame. .c om Tech nical Data 29-220 Page 60 1 \- t- M i n i m u m , r, 500 300 2 00 � I" I 00 \ � - 60 ::;; 30 20 I .... ' 10 t--.... "�-- 5 f4 3 2 1 .0 Ci). E i= .05 .01 0 "' 0 0 N 0 0 !-.�----- "' "" "' r-- 0 0 0 0 o _ o _ N 0 0 o 600 225 20 to 60 seconds Less than 1 hour 1 hour or mo re 1-/ 0 0 0 0 0 0 o o o tri .E lec w ww 30 20 2000 6000 Sheet 2 of 4 .3 .2 .1 0 0 0 0 0 o Q N 0 1ft u c 0 � Ci) (f) c (.) , [....- 4000 1, 2 , 00 M a x i m u m T i m e Delay U n i t I r "- r-- 0 Table 1 Ampere Rating I. -�1) � w 1t h o u1t r1 me D e l a y U m t - .01 .001 - Minimum Time Delay U n i t -�--- .02 Ci) E i= i -+-- I .... -...... . 03 E l ement K' .5 . 05 O perat i n g C h a racteristics Trip unit rating 500-1 600 a mperes 50°C am b i e n t. Cold start. 60 cycles. 900J442 - 60 1.0 P ercent Rated C u r rent --------.! Tri pping Time Reproduced From Drawing ' 2 Minimum Time Delay U n i t r<) ,j' l{) r--" Percent of Trip Element Rating 1 50 :r · ' \_, 600 Ll. m p T h e r m a l 1\. l A: ' ' \ }''i( 1 00 �: fJ 7 0 0 f:- Maximum Time f--- D e l ay U n i t � 0 0 0 0 I 200 � 3 W i t hout T i m e Delay 0 0 300 5 I .03 .02 500 � � l[ ....- .1 1,000 10 I nstantaneous Trip Range ( Adjustable) . see Ta b l e N u m ber ,1 .3 .2 l+!- M i n i m u m 2,000 - I � -3,000 w ,_ ca 1ft u c 0 (.) Ci) (f) c ! : g; � r-...... for Actual Va lues .5 ' - I �!= M a x i m u m 5,000 an 1 ,000 '; I N Mox1mum 1\ 3,000 2,000 w J .1 I I 1 L\ Expanded Time Delay Curve 10,000 tM g; � � 6 AQ B-AI601 Sta ndard Breaker ar I -N 5,000 10,000 lP 6 ua ls C h a racteristic C u rves � 0 2 0 � 0 0 N "' 0 0 0 0 0 0 "" "' 0 0 r-- 0 0 o _ 0 0 0 N' A mperes T i mes · 0 0 0 0 0 0 0 o o 0 0 0 0 0 o_ rO <i' .n r-: 2 10 0 0 0 N 0 I nsta ntaneous T r i p Sett i n g i n A m p e res ± 1 0% High Low 2 3 500XT1 500XT2 2000 2000 3600 3600 4000 4000 4800 4800 6000 6000 600X 600XM 2000 4000 3600 7500 4000 8000 4800 1 0000 6000 1 2000 800X 800XT1 800XT2 2000 2000 2000 3600 3600 3600 4000 4000 4000 4800 4800 4800 6000 6000 6000 1 000X 1 000XT1 2000 2000 3600 3600 4000 4000 4800 4800 6000 6000 1 200X 1 200XT1 1 200XT2 2000 2000 2000 3600 3600 3600 4000 4000 4000 4800 4800 4800 6000 6000 6000 1 400X 4000 7500 8000 1 0000 1 2000 1 600X 1 600XT1 1 600XT2 4000 4000 4000 7500 7500 7500 8000 8000 8000 1 0000 1 0000 1 0000 1 2000 1 2000 1 2000 4 Westi n g house E l ectric Corporation Distribution and Control Busi ness U n it E lectrical Components Division Pittsbu rgh, Pennsylvania, U . S .A. 1 5220 April 1 991 :J <D c. ::;· c � � Cn Types AQB-A1 601 , N Q B -A1 601 5 00 - 1 6 0 0 Amperes; 500 Volts, 6 0 H z . Ac., 75,000 Am peres I . C. C h a racteristic C u rves, Continued Factor for change in current rating of circuit breaker with change i n ambient temperature. Derating C u rve � 30 c; a; E" zo "" � 10 0o Foetor .5 1.0 1.5 2.0 2 . Known Conditions: (A) Ambient ( B ) Trip U n it Rating To determine the load cu rrent on which a trip u nit may be used when am bient is known, divide the tri p unit rating by the factor obtained from this curve for the known am bient. The result will be the max. load current on which the trip unit shou ld be used. w .E lec tri Reproduced From Drswing 900J442 Sheet 2 of 4 ww Page 6 1 AB DE-ION® Circuit Breakers for Naval Shipboard Use an tM ar I I I 0 ca u <! I I 0 :.c E A p p l icat i o n 1 . Known Conditions: ( A ) Ambient ( B ) Load Cu rrent To determine the trip unit rating to be used when the load current and amb i ent are known, m u ltiply the load current by the factor obtained from this curve for the known ambient. The result will be the ideal trip unit rating, however, since trip u n its are furnished with only the standard ratings as per Navy Specs, select the standard trip unit whose rating is eq ual to or one rating higher than the ideal rating. lP 100 90 80 70 -{!j 60 �� 50 '" � 40 29-220 ua ls April 1 99 1 Su persedes Tech n ical Data 29-220, pages 45-46, dated October 1 978 M a i led to : E, C/29-200A .c om Technical Data Westinghouse Electric Corporation Distri bution a n d Control Business U n it E l ectrical Compo nents Division Pittsburgh, Pennsylva n i a , U .S.A. 1 5220 .c om Technical Data 29-220 w .E lec tri ca lP ar tM an ua ls Page 62 ww Westi n g h o u se E l ectric Corpo ration Distri bution and Control Busi ness U nit Electrical Compon ents Division Pittsburgh, Pennsylvania, U . S .A. 1 5220 Apri l 1 991 J u ly 1 99 1 Su persedes Tech n i cal Data 29-220, pages 29-30, dated Apri I 1 99 1 M a i l e d t o : E, D , C/29-200A Types AQB -A250, N Q B -A250 250 Volts De, 500 Volts Ac 250 Am peres Maximum, 20,000 Am peres I . C . S pecificat i o n : M I L- C - 1 7361 1 25-250 A m peres 500 Volts Ac and 250 Volts De Two and Three- Pole Low High I De Low High I Complete Breaker CD Two-Pole 500 Volts Ae, 250 Volts De 225-N 225-N M 250-N 250-NM 250® 650 1 300 1 500 3000 650 1 300 1 700 3400 N o n -Auto 1 1 300 3900 1 300 3900 1 300 3900 1 650 2250 650 2250 650 2250 1 300 4 1 00 1 300 4 1 00 1 300 4 1 00 650 1 300 1 770 3550 650 1 300 1 850 3800 Non-Auto 31 3C682G03 31 3C682G04 31 3C682G05 31 3C682G06 31 3C682G07 31 3C682G08 an 5925-01 -233-6525 ca 650 1 950 650 1 950 650 1 950 31 3C682G09 31 3C682 G 1 0 31 3C682G 1 1 31 3C682G 1 2 31 3C682G31 tri 1 25 - N 1 25 - N M 1 50 - N 1 50 - N M 1 75 - N 1 75 - N M 1 AB DE-ION® Circuit Breakers for Naval Shipboard Use tM National Stock No. Style N u m ber I Breaker Frame Only CD lP List Prices See Price List 29-020 lnst. Trip Setting - Amps Page 29 AOB -A250 breakers can be ordered with u ndervoltage release devices, a u x i l iary switches and shunt trip atta chments com plete with auxiliary switc h . These attac h ments are also easily installed i n the field. ar AQB -A250 circuit breakers are used pri marily to protect feeder circ u its, however, those followed by "N M" in the price table have higher magnetic setti ngs to a l low for motor starting. Breakers with settings spe cifically for use with generators are desig nated " N G " i n the price table. Ac 29-220 These breakers are ava i l a ble w i t h i nter changeable trip u n its in ratings of 1 25, 1 50, 1 7 5, 225 and 250 amperes. The n o n automatic N O B -A250 carries a 250 ampere rating and has copper conductors replacing the trip u n it. Special generator breakers have trip u n its rated at 1 00 , 1 60, and 250 am peres. I nterrupting R a t i n g s 20,000 Amps Ac and 1 5,000 Amps De l Tech n ical Data ua ls A Q B - A250 a n d N Q B -A250 B reakers Cont. Ampere Rating .c om 8 Westinghouse Electric Corporation Distribution and Control B u s i n ess U n it E lectrical Com ponents Division Pittsburgh, Pennsylva n i a , U . S.A. 1 5220 1 1 I Trip U n it Only Style N u m ber N ati on al Stock No. 452 D370G01 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 452D370G01 452D370G01 452D370G01 452D370G01 452D370G03 5925-00-796-4371 5925-00-796-437 1 5925-00-796-4371 5925-00-796-4371 452D37 1 G09 452D37 1 G 1 0 4520371 G 1 1 452D371 G 1 2 29B27 1 0G05 452D370G01 452D370G01 452D370G01 5925-00-796-4371 5925-00-796-437 1 5925-00-796-4371 4520371 G 1 3 452D371 G 1 4 4520371 G 1 5 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 18 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 452D371 G 1 8 452D371 G 1 9 452D371 G20 452D37 1 G 2 1 452D37 1 G 2 2 452D37 1 G23 5925-00-795-4958 5925-00-839-0289 5925-00-795-4957 5925-00-839-0290 5925-00-796-4439 452D370G02 452D370G02 452D370G02 452D370G02 452D370G04 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 18 5925-00-83 1 -8801 452D37 1 G24 452D37 1 G 2 5 452D371 G26 452D37 1 G 27 29B271 0G06 5925-00-839-0291 5925-00-839-0292 5925-00-839-0293 5925-00-690-7568 5925-00-831 -8800 4520371 G28 452D371 G 2 9 452D371 G30 5925-00-852-7809 5925-00-795-4956 .............. Style N umber 4520371 G03 4520371 G04 4520371 G05 4520371 G06 4520371 G07 452D371 G08 1 00 - N G 1 60 - N G 250- N G lec Two Pole 500 Volts Ae, 250 Volts De G enerator Circuit Breaker Applications 1 1 7 5 2350 1 950 3900 . . • . . . • . . . . . . . . . . . . . . . . . 650 1 300 3 1 3 C682 G 1 3 31 3C682 G 1 4 31 3C682 G 1 5 Three- Pole 500 Volts Ae, 250 Volts De 650 1 950 650 1 950 650 1 950 1 300 41 00 1 300 41 00 1 300 4 1 00 31 3C682 G 1 8 31 3C682G 1 9 31 3C682G20 31 3C682G21 31 3C682G22 31 3C682G23 5925-00-248-1425 5925-01 -031 -9909 5925-01 -229-4448 650 1 300 1 770 3550 650 1 300 1 850 3800 N o n-Auto 31 3C682G24 3 1 3 C682G25 31 3C682G26 31 3C682G27 31 3C682G36 5925-0 1 - 1 73-2587 5925-01 -21 0-5267 ........ .. .... 5925-01-272-3805 . . . . . . . . . . . . . . 650 2250 650 2250 650 2250 1 300 3900 1 300 3900 1 300 3900 .E 1 25 - N 1 25 - N M 1 50 - N 1 50 - N M 1 75 - N 1 75 - N M 1 650 1300 1 500 3000 650 1300 1700 3400 Non-Auto w 225-N 225-N M 250-N 250- N M 250® 1 1 5925-01 -235-0710 5925-01 - 1 92-3985 1 Three-Pole 500 Volts Ac, 250 Volts De Generator Circuit Breaker Applications 1 1 7 5 2350 1 950 3900 . . . . . . . . ww 1 00 - N G 1 60 - N G 2 50 - N G . . . . . . . . . . . . . . . . 6 5 0 1 300 31 3C682G28 31 3C682G29 31 3C682G30 5925-01 -080-2226 5925-01-104-4625 . ... .. .. .. .. .. 452D370G02 452D370G02 452D370G02 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 1 National Stock No. · · · · · · · · · · · · · · . ...... ....... 5925-00-793-6865 · · · · · · · · · · · · · · 5925-00-175-5058 5925-00-064-7834 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · N ote : B reakers with rati ngs other than than those given on this page are co n s id e re d as special and full d escri pt ion data m ust be provided. CD Styles listed include slip-type connectors for rear connections. Order front terminal see page connectors separately if required; 30. No additional charges for front connectors ordered with breakers or frames. ® Type N QB-A250 non-automatic. .c om Cl Tec h n ical Data 29-220 Page 30 l AQB-A250 and NOB-A250 Breakers, Conti n u ed List Prices See Price List 29-020 l n �tantaneous Tnp Sett1ng i n AmperesCD H igh low I B reaker Frame O nly® Com plete Breaker(%) National Stock No. Style N umber Style N umber National Stock No. 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 400 Cycle, Two-Pole, 500 Volts Ac 1 25 - N H 1 50 - N H 1 75 - N H 225 - N H 250- N H 1 1 560 1 560 1 560 1 560 1 560 910 910 910 910 91 0 1 31 5C574G03 31 5C574G05 31 5C574G07 31 5C574G09 31 5C574G 1 1 1 400 Cycle, Two-Pole, 500 Volts Ac Generator Circuit Breaker Applications 3420 3420 4200 31 5C574G 1 3 31 5C574G 1 4 31 5C574G 1 5 ........ .. .... ........ .. .... .............. 400 Cycle, Three-Pole, 500 Volts Ac 1 560 1 560 1 560 1 560 1 560 910 910 910 91 0 91 0 1 25 - N H 1 50 - N H 1 75 - N H 225- N H 250 - N H I 1 31 5C574G 1 8 31 5C574G20 31 5C574G22 31 5C574G24 31 5C574G26 5925-01-075-8931 5925-01-1 00-4027 5925-01-1 93-6055 1 Style N umber National Stock No. 457D446G03 457D446G05 457D446G07 457D446G09 457D446G 1 1 .............. · · · · · · · · · · · · · · · · · · · · · · · · · · · · .............. .............. · · · · · · · · · · · · · · 457D446 G 1 3 457D446G1 4 457D446G1 5 5925-00· 758-6227 5925-00-789-3718 5925-00-789-3718 592 5-00-789-371 8 5925-00-789-3718 5925-00-789-3718 457D446G 1 8 457D446G20 457D446G22 457D446G24 457D446G26 5925-00-803-5491 5925-00-803-5488 5925-00-899-9904 5925-01-1 93-6056 5925-01-1 49-4269 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-3718 457D446G28 457D446G29 457D446G30 5925-00-238-5198 5925-00-803-5489 452D370G01 452D370G01 452D370G01 5925-00-796-437 1 5925-00-796-4371 5925-00-796-4371 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 an 2020 2020 2520 tM 1 00 - N G H 1 60 - N G H 250 - N G H Trip Unit Only ua ls Cont. Ampere Rating · · · · · · · · · · · · · · 400 Cycle, Three-Pole, 500 Volts Ac Generator Circuit Breaker Applications 2020 2020 2520 3420 3420 4200 31 5C574G28 31 5C574G29 31 5C574G30 .......... .. .. ...... .. .. .. .. .... .. ........ 452D370G02 452D370G02 452D370G02 · · · · · · · · · · · · · · ar 1 00 - N G H 1 60 - N G H 250-NG H Switch board M ou n t i n g Com plete breakers and frames include mounting hardware. Female slip connectors are mou nted in breaker base to plug onto stud projections of terminal mou nting block assem blies. Order one mounting block assembly for each end of breaker. One Stud Assembly complete with 4 n uts Terminal Mtg. Block ( N o Studs) Mounting Block and Stud Set (3 Studs) Style N umber National Stock No. lP I I 1 631 443 31 3C681 G01 31 3C680G02 ( N et Weight - 2 1> lbs.) ca Description Front C o n n ected B reakers For con nections made at front terminals, pressure-type l ugs required. If specified on same order, connectors furnished no charge. One con nector per terminal. Select below. I N40-N75 N 1 00 - N 1 25 N 1 50-N200 Amps 1 25 1 50 - 1 7 5 250 I I Description Solderless Connector K i t to C o nvert A O B Frame to N O B B reaker Poles II I Style N u m ber tri I 20B3055 H 1 4 20B3055 H 1 5 20B3055H 1 6 lec Cable Range I I National Stock No. .............. .............. ............ .. Net Weight 3 .E % lb. CD For 400 cycle breakers with higher instantaneous trip ratings, refer to Westinghouse. ® Styles listed include s l ip-type connectors for rear connections. Order front terminal connectors separately if required. N o additional charges for front con nectors o rdered with breakers or frames. ww w Westi n g ho u se Electric Corporation Distribution and Control B us i ness U n it Electrical Com ponents Division Pittsburgh, Pennsylva nia, U . S.A. 1 5220 July 1 991 8 Westinghouse Electric Corporation Distribution a nd Control B u s i ness U n it E lectrica l Com ponents D ivision Pittsb u rg h , Pennsylva n i a , U . S.A. 1 5220 J u ly 1 99 1 S u persedes Tec h n i c a l D a t a 29-220, pages 31 -32, dated April 1 99 1 M a i l ed to : E , D, C/29-200A Types AOB -A250, N O B -A250 250 Volts De, 500 Volts Ac 250 Am peres Maximum, 20,000 Am peres I . C. .c om AB DE-ION® Circuit Breakers for Naval Shipboard Use 28 V De 1 1 5 V Ac 1 Style N u mber National Stock No. 452D377G05 5925-00-831 ·8808 tM 24- 32 90- 1 30 an Voltage Range 1 20 V De 450 V Ac 90- 1 30 360-500 I 452D377G07 5925-01 -007-5836 U n d ervoltage Device: Automatically trips breaker when l i n e voltage drops below 40 to 60% of normal. After u n dervoltage coil has dropped out a nd tripped breaker o n reduced voltage, it automatically resets by breaker action. ( If u ndervoltage coil is energized to 80% of norma l ) . Select device below. Net weight., 1 . 1 2 lbs. Nominal Voltage 450 Ac, 60 Cycle 250 De 33 De I Voltage Range Pickup and Seal Volts ( M i nimum) 360-500 360 1 75-355 30- 36 1 50 22 I Dropcut Voltage 290 45 25 5 Max. M in. M in. M in. I Style Number National Stock N u mber 452D837G01 5925-00-920-3099 452D837G02 452D837G03 5950-00-790-4869 I n d i v i d u a l Rep roductions: When required, reprod uction of master drawings, outline drawings and certification sheets can be ordered as follows: Item I Description ca Contact Westing house fo r o t h e r rat i n g s or types of m o u nti n g . Nominal Voltage ar Auxiliary Switch: T h e most commonly used, when required, is style 452D379G02, national stock n u m be r 5930-00-732-840 1 . I ntern a l ly mou nted switch is used to open or close control ci rcuits as breaker operates and is provided with "A" a n d "B" contacts. "A" contact i s n o rm a l ly closed when breaker i s closed a n d open when breaker i s o pe n ; " B " i s normally o p e n when breaker is closed a n d closed with breaker open. It h a s the following rati n g at g iven voltages: 15 a m p - 1 2 5, 250 o r 460 volts A c ; '12 a m p- 1 25 volts De; % a m p-250 volts De. Net we i g ht, . 1 7 l b . Page 31 Shunt Trip: S h u nt trip attachm ents for tripping the breaker electrica l l y from a remote point a re l i sted in table below. S h u nt trips have mom entary rating o n l y and for protection m u st be connected in series with a u x i l i a ry switch . An Auxi l i a ry Switch is i ncluded in the shunt trip n u m bers shown below. Do not order sepa rately. Net weig ht, .70 l b . lP M ec h a n ical I nterlock : If mechanical interlock (switchboard use) is desired for a pair of breakers, order by descri ption. ( N ot subm itted for Navy approva l . ) 29-220 ua ls A Q B -A250 a n d N Q B -A250 B reakers, Contin ued Additions H a ndle Lock : If req uired, order style 1 7 201 01 . O ne furnished no charge per 1 0 breakers ordered, when requested. Net wt., . 1 5 lb. Tech n ica l Data 1 2 3 4 tri F u n g u s - M o isture - Resistant Treat me nts : (JAN- T-1 52; J A N - C - 1 73 or M I L V - 1 7 3 ) : If specified, contact Westi ng house. External parts are coated; trip u n its are not treated. ww w .E lec Technical Manual - NAVSHIPS No. 3622 1 64: This booklet per M I L-M-1 507 1 . When req u i red, order BVR-TM-379A. I I Full size photolithic tracing of master drawing on vel l u m Outline and dri l l i n g p l a n on v e l l u m Certification d a t a o n vellum Reproducti o n s of items 1, 2, o r 3 D rawings Ava i l a b l e : Master drawing 900- J -376; front and rear connected breaker out line, drilling and wiring diagra m 452- D - 834. Ordering I n formatio n : Page 4 N et Weight, Lbs. AOB Com plete, 3 - Pole A250 NOB Complete, 3 - Pole N 250 3- Pole AOB, NOB Frame AOB Trip U n it. 3 - Pole 20.50 1 7 .50 1 7.00 3.50 .c om Technical Data 29-220 Page 32 O u t l i n e D i m e ns i ons AOB -A250 Breaker Front face of mounting sheet or channel Support blocks ore not supplied � 2 16 with breoke')_ but must be ordered ---+--+--+ separately. r<efer to drawing 313C680 Al l ports necessary to nve r t a breo ker are included. �-16Stud 8 '--t--"---t-t-+ 4 - 20 Mtg. I Screws ua ls line End -f---W,e"Ji1�9==ii==Jri=EE6.:___,:;co tM an 11 Handle locking Device ( N ot Su pplied With Circuit Breaker) Frome Nameplate Front Sheet Visible amp rating interchangeable trip unit ar load End Warning Nameplate D r i l l i n g Plan Front Sheet D r i l l i ng Template For Term i n a l Mounting B locks lP � 1 Dio. 4 holes ca � ,k---1 3 _J�r-T (1" � r Front C o nnected Solderless Term i nals Identification Style N u m ber Cable Range A 8 MCM Min 75 50 2083055H1 5 1 25 2083055H16 200 .E Max 2083055H14 c 1 2''Ao 6"ho 5..ho 100 13 6"11• 6'Ao 1 50 1 3'11,, 7'ho 8'ho w Front Connected Terminals are not Supplied with Circuit Breaker ww s! 4 undervoltage release shunt trip or auxiliary switch leads. Hole to be dri l ied in switchboard breaker support. 5 Reorconnections 7 r1� ore on 3"centers Bottom of Front co nections mig. block a e on 24 centers lec 1 3 8 Diameter 2 holes for tri Flat washers, lock washers and nuts supplied with terminal mounting blocks Left hand side of breaker 1i Wiring D iagrams AQB NOB Line End Line End Jll Hi Load End Load End 1� Dia. 3 holes megger test for load End �)) When U nder-Voltage Release is Provided r - - - - - - - --, i : 1 J 1 i � I, : 1 When ShOJnt Trip and Auxiliary Switch i s Provided r - -- - - - -, and B Auxi li ary i l l l : sw1tch 3 l ea d s 1 � Y l, A 18" long ----. l ) )) r : Undervoltage : m� release �w!ifl\ leads • L._ _ : --J 2 18" long • L__ _ : _J Note: The auxiliary switch must be used with each shunt trip. Connect one side of shunt trip in series with "'A'' contact (Closed when breaker is closed) of auxiliary switch when connecting to power supply. leads 18" long S h u nt trip 2 Westi n g house E l ectric Corporati on Distribution a n d Control Busi ness U n it E l ectrical Com ponents Division Pittsburgh, Pennsylvania, U . S.A. 1 5220 July 1 991 .c om Technical Data Westinghouse Electric Corporation Distri bution a n d Control B u si n ess U n i t Electrical Com ponents Division Pittsburgh, Pennsylvania, U . S.A. 1 5220 Types AQB-L400QF, AQB-L400Q M ; 1 50,000 Am peres I .C. a n d AQB-LL400QS ; 1 00,000 Am peres I . C . 250-400 A m peres; 500 V o l t s 60 Hz A c Mounting Block Undervoltage Release ( Left-Pole Only) UVR and Ci rcuit Breaker m u st be ordered as a n i nteg ra l u n it Westinghouse Style Number 1 230C81 G01 Plug-in Mounting Block, Rear Connected, Complete (Required one per load or line end) Type AOB:L4000F with 1 1 5 V Ac Undervoltage Release Mechanism Westi nghouse Style Number 1 230C83G 1 5 Switchboard Mounting Breaker frame includes m o u nting h a rdware. Stud projections a re m o u nted on the rear of the breaker for plugging into fe m a l e s l i p co nnectors of term i n a l m o u nting block asse m bl ies. 1 230C83G 1 6 Handle Lock ( Fo r s h i pboard m a i ntenance use only) o rder style n u m be r 1 7201 0 1 . Mounting Block, Molded Base Only (For mounting a front connected circuit breaker, or as a replacement part) 1 230C81 G05 Male Slip Connectors (Replacement part, three per kit) 1 230C81 G04 AOB-L4000F with 1 20 V De Undervoltage Release Mechanism 1 230C83G 1 7 Front Connected Terminal (Required three per line or load end) 504C497G01 AOB-L4000F with 250 V De Undervoltage Release Mechan ism 1 230C83G 18 AOB-L4000M with 1 1 5 V Ac Undervoltage Release Mechanism 1 230C83G19 AOB-L4000M with 450 V Ac* Undervoltage Release Mechanism 1 230C83G20 AOB-L4000M with 1 20 V De Undervoltage Release Mechanism 1 230C83G21 AOB-L4000M with 250 V De Undervoltage Release Mechanism 1230C83G22 AOB-LL4000S with 1 1 5 V Ac Undervoltage Release Mechanism 1 230C83G 1 1 AOB-LL4000S with 450 V Ac* Undervoltage Release Mechanism 1 230C83G12 1 230C83G13 1 220C86G08 AOB-LL4000S with 1 20 V De Undervoltage Release Mechanism 1220C86G09 AOB-LL4000S with 250 V De Undervoltage Release Mechanism 1 230C83G14 Auxiliary Switch 1 a/1b 1 1 5-450 V Ac 2a/2b 1 1 5-450 V Ac 1 a/1b 120 V De 2a/2b 1 20 V De 1 a/1b 1 1 5-450 V Ac and 1 a/1b 1 20 V De Combination 1 220C86G01 1 220C86G02 1 220C86G05 1 220C86G06 1 220C86G07 Shunt Trip Type 1 220C86G03 1 220C86G04 lec Combination Shunt Trip and 1 a/1b Auxiliary Switch (LeftPole Only) tri Westinghouse Style Number Shunt Trip (Left-Pole only) (Includes built-in cutoff switch) 1 1 5 V Ac/28 to 1 20 V De 450 V Ac Only ww w .E 1 1 5 V Ac/28-1 20 V De Shunt Trip and 1 1 5-450 V Ac Auxiliary Switch 1 1 5 V Ac/28-1 20 V De Shunt Trip and 120 V De Auxiliary Switch 450 V Ac Shunt Trip and 1 1 5-450 V Ac Auxiliary Switch 450 V Ac Shunt Trip and 1 20 V De Auxiliary Switch ar Westinghouse Style Number ca Type lP Auxiliary Switches tM AOB-L4000F with 450 V Ac* Undervoltage Release Mechanism 1 220C86G 1 0 1 220C86G 1 1 Fungus - Moisture - Resistance Treatments: (JAN-T- 1 52 ; JAN-C- 1 73; M I L-V-1 73) If specified contact Westinghouse. Exte rnal parts a re coated. Technical Manual: When req u i red o rd e r 1 240C33H01 . Portable Test Kit - Can be used to functiona l ly test the breaker for ove rload a n d s h o rt circuit, wh i l e breaker is m o u nted. When req u i red o rder cata log n u m be r STK2. Individual Reproduction : When req u i red reproduction of outl i n e d rawings a n d certification sheets can be ordered a s fo l l ows: Item 1 2 3 Description Outline drawing and drilling plan on vellum Certification data on vellum Reproduction of items 1 and 2 Repair Parts: Net Weight: *Using externally-mounted step-down transformer supplied AB DE-ION® Circuit Breakers for Naval Shipboard Use an Type Page 43 ua ls July 1 99 1 Supersedes Technica l Data 29-220, pages 43-44, dated April 1 99 1 Mailed t o : E, D , C/29-200A 29-220 Item Circuit Breaker Motor Operator Mounting Block Front Connected Terminals (Set of Three) Portable Test Kit Weight 30 lbs. 22 lbs. 10 lbs. 1 lb.-10V• ozs. 12 lb.-14'14 ozs. .c om Tec h n i ca l Data 29-220 w .E lec tri ca lP ar tM an ua ls Page 44 ww Westi nghouse E l ectric Corpo ration Distribution and Control Busi ness U n it E l ectrical Com ponents Division Pittsburg h , Pen n sylva nia, U . S .A. 1 5220 July 1 991 .c om Technical Data Westinghouse Electric Corporation Distribution a n d Control Busi ness U n i t Electrical Compo nents Division Pitts b u rg h , Pennsylva nia, U .S.A. 1 5220 J u ly 1 99 1 Su persedes Technical Data 29-220, pages 45-46, dated April 1 99 1 Mai led to: E, D, C/29-200A • Navy Type AQB-L400QF Circuit Breaker -c�--::-::t=: :: :=-c--'--1 Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C� to + 70 Deg. C. ar � :-::-cr=±=cccc==l tM Rating Plug: 2500 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. AB DE-ION® Circuit Breakers for Naval Shipboard Use an Navy Type AOB-L400QF Circuit Breaker Page 45 ua ls • Types AQB-L4000F, AQB-L4000 M ; 1 50,000 Am peres I .C. a n d AQB-LL400QS; 1 00,000 A m peres I .C. 250-400 A m peres; 500 Volts 60 H z Ac 29-220 : : -:-::::1 100 < �- �� � .z § .E lec tri ca lP - �-�-1 50 ww w Time-Current Curves for AOB-L4000F Circuit Breaker with 250 Ampere Rating Plug Time-Current Curves for AOB-L4000F Circuit Breaker with 300 Ampere Rating Plug 1 .c om Tech nical Data 29-220 Page 46 • Navy Type AQB-L400QF Circuit Breaker = : - =:::::= I :: Rating Plug: 3500 �-- - · 1 •--- - H1gh Setng _: --� � l;o,-:--cf-+==o--,---l=t±c!= I6�S"; 1 1 500 A) I - 1 10 -;-----t -r--..._. • ----- -� ' --=�- ; -� � 0 lec an tri ca lP __ 0 ar � Delay P1ck-Up ;--t-t--- -- Curve Tolerance Applies Over Temperature Range of -20 Deg. C. to + 70 Deg. C. woo -----'-----t--+ - - < 2 - -�- T:�- - � ; �-- -� _; ;·: �� , Short -------r - · � :::; tM Curve Tolerance Applies Over Temperature Range of - 2 0 Deg. C. t o + 7 0 Deg. C. Navy Type AQB-L400QF Circuit Breaker ua ls • Time-Current Curves for AQB-L400QF Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AQB-L400QF Circuit Breaker with 350 Ampere Rating Plug ww w Westi nghouse E l ectric Corporation Distribution and Control Busi ness U n i t E lectrical Components Division Pittsburgh, Pennsylva nia, U .S.A. 1 5220 July 1 991 J u ly 1 99 1 S u persedes Technical Data 29-220, pages 47-48, dated Apri l 1 99 1 M a i led to: E, D, C/29-200A • . :-r---- � + -- ---- AB DE-ION® Circuit Breakers for Naval Shipboard Use Navy Type AQB-l400QM Circuit Breaker Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. ,___ ar � Page 47 lP I tM Rating Plug: 2500 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. 29-220 an Navy Type AQB-l400QM Circuit Breaker Tec h n ical Data ua ls • Types AQB-L400QF, AQB-L400Q M ; 1 50,000 Am peres I .C. a n d AQB-LL400QS; 1 00,000 Am peres I .C. 250-400 Am peres; 500 Volts 60 Hz Ac .c om Westinghouse Electric Corporation Distribution a n d Control Busi ness U n it Electrical Compon ents Division Pittsburgh, Pen nsylva n i a , U . S.A. 1 5220 tri ca ·------+-�-+--�---< · ��-� .-+--. o .E lec . • 1 - --l l ww w Time-Current Curves for AOB-L4000M Circuit Breaker with 250 Ampere Rating Plug Time-Current Curves for AOB-L4000M Circuit Breaker with 300 Ampere Rating Plug .c om Technical Data 29-220 Page 48 • Navy Type AQB-L400QM Circuit Breaker Navy Type AQB-L400QM Circuit Breaker ua ls • Rating Plug: 4000 � - ---· -+--- lec tri ca lP ar tM ' r-� 1uoo [ an Curve Tolerance Applies Over Temperature Range of - 20 Oeg. C. to + 10 Deg. C. Time-Current Curves for AOB-L4000M Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AOB-L4000M Circuit Breaker with 350 Ampere Rating Plug ww w Westi ngh ouse E l ectric Corporation Distribution a n d Control Busi ness U n it E lectrical Components Division Pittsburgh, Pennsylva nia, U . S.A. 1 5220 July 1 991 • Navy Type AQB-LL400QS Circuit Breaker ar tM Rating Plug: 2500 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. Navy Type AQB-LL400QS an Circuit Breaker Page 49 ua ls • 29-220 AB DE-ION® Circuit Breakers for Naval Shipboard Use Types AQB-L400, AQB-LL400 500 Volts Ac 400 Am peres Maxi m u m , 1 50,000, 1 00,000 Am peres I.C., Respectively J u l y 1 99 1 S u persedes Tech nical Data 29-220, pages 49-50, dated April 1 99 1 M a i led t o : E, D , C/29-200A < � ��'�'m·u·m Te�p �� ---- + •� :;: Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Oeg. C. to + 70 Oeg. C. T1me • �� �--- .E lec tri ca lP -------�� - .c om Tech nical Data Westinghouse Electric Corporation Distribution a n d Control Business Unit Electrical Components Division Pittsburgh, Penn sylva n i a , U . S . A. 1 5220 _ _ l___ LL.J ww w Time-Current Curves for AOB-LL400QS Circuit Breaker with 250 Ampere Rating Plug oo1 Time-Current Curves for AOB-LL400QS Circuit Breaker with 300 Ampere Rating Plug .c om Tech nical Data 29-220 Page 50 • Navy Type AQB-LL400QS Circuit Breaker Rating Plug: 3500 Navy Type AQB-LL400QS Circuit Breaker ua ls • i -� -i lGilil Curve Tolerance Applies Over Temperature Range of -20 Deg. C. to + 70 Oeg. C. t i "' ·ooo an Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. ! lec tri ca lP ar tM · ;t 1oo Time-Current Curves for AOB-LL4000S Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AOB-LL4000S Circuit Breaker with 350 Ampere Rating Plug ww w Westing house E l ectric Corpo rati on Distribution a n d Control Busi ness U n it Electrical Components Division Pittsburgh, Pennsylvania, U .S.A. 1 5220 July 1 991 .c om Westinghouse Electric Corporation Distribution and Control Busi ness Unit E l ectrical Components Division Pittsburgh, Pen nsylva nia, U . S.A. 1 5220 J u l y 1 99 1 Supersedes Tech n ical Data 29-220, pages 51 -52, dated Apri l 1 99 1 M a i l e d to: E, D, C/29-200A 29-220 Page 51 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Types AQB-L400, AOB-LL400 500 Volts Ac 400 Amperes M a x i m u m , 1 50,000, 1 00,000 Am peres I .C., Respectively Tech n ical Data tM an Outline Dimension AQB-L400, AOB-LL400 Automatic Tripped ar ( ' ' ,I Front Surface of Mounting Panel ,I lP 16 I 103/16 tri ca Reset Max ww w .E lec Dimensions in Inches t 2 1 3132 Load End 2 1 7132 Line End *Conductor Height for Front Connection 14% .c om Technica l Data 29-220 Page 52 Outline AQB-L400, AQB-LL400 with Motor Operator 101 '116 16 0 r- 627/32 I ---+--- II 0 Automatic Tripped I-f--I-f--'---f-- 513/16 Off Reset Max. I ' @ @ ! I I @ @ �� Lo ad End 99/1 6 14'14 ,, u 5f1 s-18 Mounting H a rdware Dimensions in Inches w .E lec tri ca �( ua ls @ ar 81116 @ lP 11'/32 @ Lin e End an @ )� tM ,/ l ww Westi nghouse E l ectric Corporati on Distribution a n d Control Busi ness Unit E l ectrical Components Division Pittsburgh, Pennsylvania, U . S.A. 1 5220 J u ly 1 991 .c om 8 Tech n ical Data Westinghouse Electric Corporation Distribution a n d Control B u s i n ess U n it E l ectrical Components Division Pittsburgh, Pennsy lv a n i a , U . S.A. 1 5220 • AB DE-ION® Circuit Breakers for Naval Shipboard Use A Q B - A 1 601 a n d N Q B -A 1 601 N avy B reakers • • Note: AQB-A 1 601 are sold for replace ment only. They are no longer on the Navy Qualified Products List. lP ar tM an • Page 55 ua ls Types AQB -A1 601 , N Q B -A1 601 500 - 1 600 Am peres; 500 Volts, 60 H z Ac, 75,000 Amperes I . C . J u l y 1 99 1 S u pe rsedes Tech nical D a t a 29-220, pages 55-56, dated April 1 99 1 M a i led to: E, D, C/29-200A 29-220 • • ��"-·���"_,.··��- ca Complete Breaker List Prices See Price List 29-020 3 Pole, 500 Volts, 60 Cycles A-c Breaker O n ly, consists o f : tri Type Continuous Instantaneous Trip Setting Ampere A-c Amperes Rating Low High Frame (Includes Stabs) National Stock N u mber 'I lec Style N u m ber Trip u n its for these breakers have an adjust able i nsta ntaneous trip and are l i sted with a nd without delayed instantaneous trip for system coord i nation. Trip U n i t Style N umber National Stock N u m ber Without Delayed Instantaneous Trip 600X 600XM 800X 1 OOOX 1 200X 1 400X 1 600X 1 600 2000 4000 2000 2000 2000 4000 4000 6000 1 2000 6000 6000 6000 1 2000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G04 .E AQB AQB AQB AQB AQB AQB AQB NQB 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 3720523G01 3720523G03 3720523G07 3720524G03 3720524G05 3720524G07 3720524G09 3720524G 10 2000 2000 2000 2000 4000 6000 6000 6000 6000 1 2000 1 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-01 -1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 1 374021 1 G01 374021 1 G 07 3740 2 1 2 G03 374021 2G05 374021 2G09 5925-00-406-61 31 5925-00-1 02-6086 5925-00-727-7574 w With Delayed Instantaneous Trip (XT2 - Max. Time Delay .0708 - .0750 Sec.) ww AQB 500XT2 AQB 800XT2 AQB 1 200XT2 AQB 1 600XT2 :!000 2000 2000 4000 6000 6000 6000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 5925-01 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 37402 2 1 G01 3740221 G07 3740222G05 3740222G09 N Q B - A 1 601 Breakers have a continuous rating of 1 600 a mperes. They are used only as d iscon nects since they do not have a n automatic t r i p device. Note : B reakers with rati ngs other than those l isted above are considered as special a nd f u l l descriptive data must be provided. With Delayed Instantaneous Trip (XT1 - M i n . Time Delay .041 7 - .0458 Sec.) AQB 500XT1 AQB 800XT1 AQB 1 000XT1 AQB 1 200XT1 AQB 1 600XT1 AQB-A 1 601 circuit breakers are designed for i nsta l l ation i n switchboards for protec tion of gen erators a nd feeder a nd branch circu its. A complete breaker consists of a breaker p l us mounting base a nd is available with n u mer ous attachments such as electrical operator, shunt trip, u n dervoltage release a n d a ux i l iary switches to perform varied auxil iary func tions. � � " Breaker Only 500-1 600 Am peres, 500 Volts A-c, 60 Cycles O n ly, 3- P o l e, 50°C A m b i ent I nterrupting R a t i n g : 75,000 Amps. A - c (Without Delayed I nsta ntaneous) 50,000 A m ps . A-c {With Del ayed I nsta nta neous) S pecificati o n : M I L- C - 1 7361 C l ass : H i S h ock M I L-S-901 Vi brati o n : M I L- S T D - 1 67 M aterial a n d Work m a n s h i p : M I L- E -91 7 5925-00-727-7555 5925-00-1 03-4248 400 cycle breakers are not ava i l a b l e . 29-220 Page 56 Mounting BaseCD .c om Tech ni cal Data N et Weig hts Optional Additions(]) ua ls Shunt Trip @ : M o u nts i n right pole o n l y . Has momentary rating o n l y ; coil leads m u st be wired in series with 1 A contact of aux i l i a ry switch. Description Undervoltage Release@ : M ounts i n right pole only. Electrical Operator, 1 1 5 Volt Electrical O perator, 450 Volt Shunt Trip Undervoltage Release Auxili ary Switch Cable Con nector an Auxiliary Switch : M o u nts i n left pole only. 4 co ntacts, a ny co m b i nation of A's a n d B's, (su p p l ied as 2A and 2B u n l es s specified) 8 contacts, any combi nation of A's and B's, ( s u p p l ied a s 4A a n d 4B u n l es s specified) B reaker Only AQB NQB Breaker Frame (AQB and N Q B ) Trip U n it AQB NQB M ounting Base O n l y For switch board mounting. I n c l udes back connectors for switchboard bus and male stabs to engage breaker. M atching stabs are suppl ied with breaker frame. Cable Con nector : M o u nts to b us connector fo r cable co n nection. Each lug accepts fo u r cables, 600 M C M max. 1 l u g req u i red p e r bus co nnector. Style N u m be r : 505C706G03 1 51 1 48 1 28 23 20 75 27 35 * 1% a 3 Ordering I nformation When orderi ng Westi ngho use N avy circuit breakers consult the check l ist below to make sure you have provided correct infor mation. You should specify: ar Style N u mber: 373D307G02 tM Automatic Reset Switch For use with m otor o perator when an auto matic reset fu nction is req u i red. Factory in stal led only. Weight, Lbs. 1 . Q u a ntity, West i n g h o u s e style n u m b e r a n d N a t i o n a l stock n u m b e r of: Fungus, Moisture Resistant Treatment: (a) B reaker frame and trip u n it. (JAN-C- 1 73 or M I L-V- 1 7 3) : If s pecified, co n (b) M o u nting base. tact Westi ngh ouse. Exte rnal p a rts are coated; (c) Spare breakers or trip u nits. ( U sually tri p u n its a re not treated. one req uired for each ten u nits or Drawings fraction thereof of each current M aster p l a n : 900J442 rati ng.) (d) I nstruction books. S h eet 1 of 4: Breaker O n l y a n d Wi r i n g d i a grams 2. S h i p me n t S h eet 2 of 4 : Trip U n it, Cu rves and Attach Specify transportation means, method o f ments packag ing and preservation a n d requi red S h eet 3 of 4 : M o u nt i ng Base and Cable s h i p p i n g d at e . Conn ectors S h eet 4 of 4: Motor Operator 3 . D rawi n g s Individual Reproductions: When req u i red, Specify quantity o f outline o r master p l a n reproductions of sheets 1 t h r u 4 of m a ster drawings req u i red. p l a n 900J442 can be ordered as fol l ows: 4. Inspection T y p e Reproduction Indicate whether Government S o u rce Vellum i n s pection is req u i re d at facto r y prior to Prints (Paper) s h i pment. .E lec tri ca lP Electrical OperatorCD Technical Manual: NAVSH I P S No. 0962-0 1 45000. This booklet p e r M I L- M- 1 507 1 . When req u i red, o rder BVR-TM-576. M o u nts to front of breaker for remote o pe ra tion. 450 volt Ac rating utilizes a transfo r m e r Dimensions: Pages 57, 58, 59 i n conjunct i on w i t h a 1 20 volt m otor. I f auto matic reset is d e s i red, o rder t he circuit Characteristic Curves : Pages 60, 61 breaker with o pt i on a l Automatic Reset Switch (See Opti o n a l Additions) CD Can b e field mounted. w Rating ww 1 20 V A-c 450 V A-c Style Number National Stock N u m be r 1 37 1 D3BG06 1 37 1 D3BGOB None Assig ned Westi nghouse E l ectric Corporation Distribution a n d Control B u s i ness Unit E l ectrical Components Division Pitts b u rg h , Pen nsylvania, U . S.A. 1 5220 ® Breaker can be supplied with either shunt trip or undervoltage release, but not both. July 1 991 J u ly 1 99 1 S u persedes Technical Data 29-220, pages 57-58, dated April 1 99 1 M a i led to: E. D, C/29-200A Types AOB-A1 601 , N O B -A1 6 0 1 500- 1 60 0 Amperes; 500 Volts, 6 0 H z. Ac. 7 5, 0 0 0 Am peres I .C. .c om 8 Westinghouse Electric Corporation Distri bution a n d Control Busines s U n i t E l ectrical Com pon ents Division Pittsburgh, Pennsylva n i a , U . S .A. 1 5220 Technica l Data 29-220 Page 57 ua ls AB DE-ION® Circuit Breakers for Naval Shipboard Use A O B a nd N O B C i rcuit B reaker Frame O u t l i ne D i mensions N OB-S a m e except for t r i p u n i t n a mepl ate. Front Panel Cutout ar tM an <t. of Breaker }..+---+- Removable Handle lP Extension Supplied with Breaker ca � � 44 Line tri 14 � lec Mountmg Screws When undervo ltage release and auxiliary switches are provided .E W i r i n g D i agrams AOB NOB r rn i c r)-r; r ::���r\ r Line When shunt trip and auxi liary switch are provided Line w ' t\ . � !, , ill ���::: �W ww L- - - -- - - - - - - - - LOOd 18 Inches Long Load 900J442 Sheet . : ;_ _ - - - - - - - - - - - - - - Reproduced From Drawing 2J 1 of 4 ___ --· __ _ --· _ _ _ _ _ _ _ _ _ _ _ ; Undervoltage ; Releose 2 Leods j 18 Inches Long r-r �f�E�t· ) / � "I ) � 18 1nches Long ::J; Tnp : ; 2Shuni L° d ' I �: 18 ln h s Long ' Note : The auxil iary switch must be used with each shunt trip . Con nect one side of shunt trip in series with "A" contact ( c l osed when breaker is closed) of auxil iary switch when connecting to power supply. .c om Technical Data 29-220 Page 58 M o u nt i n g Base O u t l i n e D i mensions c -" ua ls Top View ���------� 1 ==rr-=�=�=-=--=-'fi' an Sw1tchboord Bock Panel 0 0 0 tM f----- 12 ,� -----+! S w 1 t c h boord Moun t m g Angle I ca lP ar Side View � -16 Top 4 Hol es tri ( Breaker Mou nt1ng ) lec Front View C utout F ront Panel Cutout ww w .E For Switchboard Back Panel Reproduced From Drawing It_ of Breaker M ou n t i n g Base With cable connectors style 505C706G03 lug capacity�four 600 M C M cables per l u g O u t l t n e of Mount1ng Bose 900J442 Sheet 3 of 4 J u ly 1 991 .c om Technical Data 29-220 Westi n g house E l ectric Corporation Low Voltage Breaker D ivision Beaver, Pennsylvania 1 5009 Page 1 5 to 1 60 0 Amperes 1 50 0 to 1 00,000 Amperes I. C . AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls October, 1 97 8 Supersedes Price List 2 9 - 220, pages 1 - 2 , dated February 1 7, 1 969, and Supp. page .01 dated September 26, 1 974 lP ar tM an M a i led to: E, C/1 905/PL ca Selector G u id e for A p p roved Navy C i rcuit B reakers Breaker Type tri ALB-1 lec .E w M I L- C - 1 7588 I H i -S hock Spec M I L-S-901 I I No. Ampere of Rating Poles 1 5- 50 M I L- C - 1 7588 M I L-S-901 1 AOB-A100 M I L- C - 1 7361 M I L-S-901 2. 3 1 5- 1 00 N OB-A100 M I L-C-1 7361 M I L-S-901 2, 3 1 00 AOB-A101 M I L- C- 1 7361 M I L-S-901 3 N LB-1 ww I Specification 50 1 5- 1 00 1 25 V De 1 25 V Ac 1 25 V De 1 25 V Ac 250 V De 500 V Ac I I nterruptmg Rating, Amperes 2,500@ 5,000@ I Tripping Elements Thermal M a gnetic None 1 0,000 1 5,000 I Page 5 5 Thermal Magnetic 11 None 11 500 V De 250 V De 250 V De 500 V Ac 1 0,000 1 5,000 Thermal M agnetic 15 500 250 250 500 None 15 1 5,000 20,000 Thermal Mag netic 23 None 23 Thermal Magnetic 29 None 29 N OB-A101 M I L-C-1 7361 M I L-S-901 3 AOB-A250 M I L- C - 1 7361 M I L-S-901 2, 3 1 25 - 250 N O B-A250 Ml L-C-1 7361 M I L-S-901 2, 3 250 AOB-A600 M I L- C - 1 7361 M I L-S-901 2, 3 250- 600 N O B-A600 M I L- C - 1 7361 M I L-S-901 2, 3 600 250 V De 500 V Ac AOB-LF100 M I L-C-1 7361 M I L-S-901 3 1 5- 1 00 500 V Ac 1 00,000 A O B - L F250 M I L-C-1 7361 M I L-S-901 3 1 25 - 250 500 V Ac 1 00,000 AOB-A1 601 M I L- C - 1 7361 ( M odified) M I L- C - 1 7361 ( M odified) M I L-S-901 3 500-1 600 500 V Ac 75,000 M I L-S-901 3 1 600 500 V Ac N O B -A1 601 1 00 I Voltage Rating V Ac V De V De V Ac 250 V De 500 V Ac 250 V De 500 V Ac @ A 5 a mpere breaker has an interrupting rating of 1 500 a mperes Ac or De. 20,000 30,000 Thermal M agnetic Fuses Thermal Magnetic Fuses Thermal Magnetic None 34 35 39 39 .c om Tec h n ica l Data 29-220 Page 2 ua ls Desc r i pt i o n These molded case N avy circuit breakers provide both overload protection for c o n ductors and short circuit protection f o r a l l circuit elements such as conductors, motors and starters. They also serve as manual dis connecting means as well as circuit pro tectors. A l l Westi nghouse circuit breakers in this Technical Data meet appl icable N avy spec i fications for " h i -shock". These manually operated breakers are rated from 5 to 1 600 am peres with interrupting ratings from 1 , 500 to 1 00,000 am peres. (See "selector gu ide" on page one for ratings and N avy speci fications.) an O pe r a t i n g H a n d l e S h own I n =1---��!--- I..Jtt Position tM Des i g n Features Westingh ouse Navy circuit breakers reta in a l l the features of standard commercial type AB De-ion breakers listed on the next page u nder "standard features." B u ilt to N avy specifications, they i ncorporate the follow ing N avy requirements: S pecific Navy Features @ A n t i - S hock Device: I nertia weight over center pole holds trip bar i n latched position u nder shock conditions but does not prevent thermal or magnetic trip u nits from functioning on overload and short circuits. @ C a l i b rated for 5o· c : All ar ,------- ------, L------ T'er� m i na i S t u d s tri Navy brea k ers are cali brated for shi pboard installation at 5o·c ambient. Front view ot assembled AOB -A250 Navy circuit breaker. Note that the shock resistant, glass alkyd material ( MAI-60) used for housing and cover i s l i g ht gray, while standard molded case breakers are black. lP Resistant M o lded Case: Housing consists of rear base section and cover molded of glass alkyd material. This material, identified as M A I - 6 0 or M A I - 30, has very high mechanical strength (shock and impact resista nce), is both fire and moisture- resistant and provides excellent diel ectric characteristics. ca G) S h ock @ I nterc h a n g ea b l e Trip U n its: All ther lec mal and magnetic trip u n its i n AQB circuit breakers are encased i n sealed, self-con tained u n its that are interchangeable with other trip u n its of different a mpere rati ngs within the same frame size. @ @ P l u g - i n C o n nectors: All AQB break w .E ers are designed for easy p l u g - i n installa tion. P l ug - i n type connectors are built into the base of the breaker for use with molded mounting blocks complete with studs. For front connection, pressure-type cable ter minals are used instead of p l u g - i n con nectors. ® ALB breakers have a clamp ter minal on the line end to receive panelboard bus stab projections. @ Interchangeable trip units are not available i n the ww A101 or A L B- 1 . @ All A 1 01 breakers have plug-in connectors. Front or rear connectors determined by mounting base selected. Rear view of AOB-A600 breaker showing terminal blocks f o r switchboard mou ntin g . (Terminal block attached at l i ne end of breaker and removed from load end.) October, 1 97 8 Su persedes Price List 2 9 - 2 2 0 , pages 1 - 2, dated February, 1 969 5 t o 1 60 0 Am peres 1 50 0 to 1 00,000 Am peres I. C. Tec h n ical Data 29-220 Page 3 AB DE-ION® Circuit Breakers for Naval Shipboard U se ua ls M a i led to: E, C/1 905/PL Standard Features G) Co rrosi o n - Resistant: an All parts are specially treated to resist corrosion. Fungus moisture resistant treatments for severe at mospheres are available as modifications. @ Positive Positi o n I n d icatio n : Posi tion of handle always indicates ON, O F F, or TRIPPED. tM @ Free Bearing S u rfaces: Dissimilar metals are used to prevent bearing wear and eliminate sticking. @ De-ion @ S i lver A l loy C o ntacts: Special silver ar ca alloy contacts prevent sticking and weld ing, increase contact l ife and insure low resis tance when carrying f u l l - rated load. -iii'+--- lP Arc Quenchers : This West inghouse development consists of a series of grid plates mou nted in parallel between s u pports of i nsulating material. The slots i n t h e steel plates are directly over t h e contacts and draw the arc from the moving contact u p i nto the divided chamber where it is con fined, divided, and exti ngu ished. @ Q u i c k - M a ke , tri Q u i c k - B re a k O v e r Center Tog g l e M ec h a n i s m : Provides quick, positive action in opening and c los ing of circ uits, prevents "teasing" of con tacts and reduces contact wear. Arc C h utes M oving Contact Operat i n g Mechanism T r i p U n it Trip U n it R e m oved (j) C o m p lete l nterpole B a rriers: I nsure internal occur. @ Common f l a s h overs when fa ults lec a g a i nst Trip: Two and three- pole u nits have insu lated common trip bar that opens all poles simultaneously when an overload occurs o n any one, thus eliminat ing possibil ity of single- phasing. .E ® Tested Accuracy: All tripping mem bers have ground and polished latch sur faces heat treated to prevent galling or later distortion. All parts are assembled in tem perature-controlled atmosphere t o assure · correct cali bration and perfect mating. Each breaker is thoroughly tested. w @ Factory Sealed: ww Smal ler breakers are factory sealed to prevent tampering with calibration. I nterchangeable trip u n its are individually sealed. .c om e West i ng h ouse Electric Corporat ion Low Voltage Breaker D ivision Beaver, Pennsylvania 1 50 0 9 Breaker Front Cover R e m oved Arc Chute Rem oved ----ii;; .c om Technical Data 29-220 Page 4 G eneral O rd e r i n g I nformat i o n W h e n ordering Westinghouse N avy c i rc u it breakers, consult the check list below to make sure you have provided correct i nfor mation. You should specify: ua ls A p p l ication Desi g n ed primarily for circ u it protection, Westingh ouse Navy circuit breakers are used i n l i g hting a n d power panels, switchboards, distribution centers and l o a d centers aboard ship. The photograph below i l lustrates the use of molded case circ u it breakers i n a typical N avy switchboard. 1 . Quantity, Westing house Style N u mber and Federal Stock N u mber of: a . Complete breaker or frame, trip u n it, fuses (where required) and/or attachments where ava i lable. b. Plug-in mounting block or front con necting cable term inals. an c . Spare breakers or trip u n its. ( u sually one req u i red for each ten u n its or fraction there of of each cu rrent rati n g . ) d . I n struction books. tM 2 . Shi pment: Specify transportation mea ns, method of packaging and preservation, and req u i red shi pping date. .E lec tri ca lP ar 3 . Drawings: Specify qu antity of outline or master plan draw i n gs required. ww w Westing house Electric Corporation Low Voltage Breaker D ivision Beaver, Pen nsylva nia 1 5009 4 . I nspection: I ndi cate whether Navy i nspection is re q u i red at factory prior to shipment. Types ALB- 1 , N LB - 1 , 1 25 Volts Ac a n d De, 50 Am peres M a x i m u m , 5000 A m peres I . C. AB DE-ION® Circuit Breakers for Naval Shipboard Use M a i l e d to: E, C/1 905/PL Net Prices Refer to Price List 29-020 Circuit Breakers - N et Weig ht: 8 oz. Ampere Rating Type ____ A.LB-1 ALB-1 ALB-1 ALB-1 ALB-1 5 10 15 20 25 ALB-1 ALB-1 ALB-1 ALB-1 N L B- 1 ® tM ar ca -- - - - -- lec The N LB-1 breaker i s the non-automatic de sign of the ALB- 1 . Si nce the tripping e l ement i s o m itted, it i s u sed as a m a n u a l d i scon nect. .E N o n-adjustable thermal a n d magnetic trip elem ents a re factory ca l i brated a n d sea l e d . The t r i p p i n g element i s counterbalanced t o reduce poss i b i l ity of accidenta l t r i p p i n g u n d e r s h ock. A l l parts are g i v e n a corrosion resistant treatment in complia nce with M I L-E-9 1 7 . ww w Plug-in l i n e connections s i m p l ify p a n el board m ounting. A c l a m p type terminal o n the l i n e end of t h e breaker provides p l u g - i n conn ec tion to bus stabs in panel board mou nting blocks. For front con nection, there i s a p res s u re type terminal on the load end of the breaker. Test report number 5530-5. ------ Single breaker, front panel supported Single breaker, surface mounted Two breakers, front panel supported De, sing le phase® and part ( 1 /3) of combination for 3-phase® Part (2/3) of combination for 3-phase application® 3-phase panel application® De, single phase® and part ( 1 /3) of combination for 3-phase® tri H i g h sh ock Navy ALB-1 circuit breakers are designed for s h i pboard protecti on of single phase Ac a n d De circuits o r th ree-phase Ac ci rcuits when breakers are con nected by han d l e yokes for 2 a n d 3-pole operati on. 454D507G06 454D507G07 454D507G08 454D507G09 454D507G 1 0 H 5925-00-549-5360 H 59 2 5-00-549-5362 H592 5-00-546-3076 H592 5-00-549-5365 H 5930-00-548-7068 Mounting Blocks Type I nterrupting Rating 1 0-50 Amp U n its: 5,000 Amps Ac and 2500 Amps De 5 Amp U n i t : 1 , 500 Amps Ac or De Nationa I Stock No. Style Number =-:"c � ---454D507� G� 0� 1------H 5925-00-204-l:-:4�94�-454D507G02 H5925-00-204-7488 H 5925-00-549-5366 454D507G03 454D507G04 H 5925-00-50 1 -5051 454D507G05 H 5925-00-549-5359 Special ALB-1 and NLB-1 Breakers S i m i l a r to a bove except to have a 1 A- 1 B a u x i l i a ry switch rated 5 a m p resistive, 250 volts Ac o r 3 0 volts D e m a x . ( N ot s u b m itted f o r Navy a p p roval, a n d does not u s e breaker rr0unting blocks). Order by description . lP ALB-1 Navy circuit breaker. Note clamp type stab terminal for panelboard mount ing at line end and pressure type termi nal for front connec tion at load end. 30 35 40 50 50 Page 5 an ALB-1 and NLB-1 Breakers Specification: MIL-C-17588 5-50 Amperes, 60 or 400 Cycle 1 25 Volts Ac o r De S i ng l e Pole .c om May, 1 980 Su persedes Price List 29-220, pages 5-6 dated October, 1 978 Tech n ical Data 29-220 ua ls Cl Westinghouse Electric Corporation Low Voltage Breaker Division Beaver, Pen n sylva n i a 1 5009 Top view of typical ALB-1 panelboard mount ing block. (Style 454D509G04) Style Number Net Wt. in Lbs. 454D509G03 National Stock No. None Assigned None Assigned None Assigned 454D509G04 H 5925-00-20 1 - 7 1 77 454D509G05 H 5925-00-201 -7 1 75 -- --- --- --- - 454D509G01 454D509G02 454D509G06 H5925-00-544-5980 454D509G08 H5925-00-201 -7 1 76 v. v. '!, ' 13 ' 13 2 /3 Individual Reproductions: When req u i red, reproductions of master d rawings, outl i n e draw i ngs and certification sheets ca n be o rdered a s fol l ows: Description Full size phoiolithic traC.i ng of m-Bster drawillg on crO.n oflex (rflv�Outline and d rilling plan on cronoflex (mylar) Certification data on cronoflex (mylar) Van Dyke negative of items 1 and 2 Reproductions of items 1, 2 or 3 Item 1 2 3 4 5 Drawings Available: M a ster drawing 900J396; breaker outl i n e 31 4C2 1 8 ; mou nting blocks 455D791 a n d 369D592. - --- - Technical Manua l : N avships No. 362-2228. This booklet per M I L-M - 1 507 1 . When re qui red, order BVR-TM-378. Handle Yokes: Provide i nterlocking of two or th ree one-po l e breakers for sim ultaneous oper ation. Individual pole tripping i s obta i ned without normal trip i n d icating (center) posit i o n . _____ Style Number Poles 2 -- - 2078508H01 2078508H02 3 ® Tripping element o mitted for manual disconnect. Letter "'N"' hot stamped in white on handle. ® I n De or single phase panel applications, basic pattern is one molded base accommodating four single-pole break ers. (See pages and 8.) 7 @ ® _ __ National Stockc_Ncco=-c. H5925-00-202-0938 H 5925-00-296-8926 In 3-phase application where basic pattern is three molded bases, one 454D509G04 and two 454D509G05 are required, each base accommodating two breakers per cir cuit (See page For 3-phase application where basic pattern is one molded base accommodating up to six breakers or two breakers per circuit (See pages and 9.) 7.) 8 .c om Cl Tech nical Data 29-220 Page 6 Outline Dimensions ALB-1 Breaker a n d M o u nting B l ocks Breaker Outline Single Base, Front Panel Supported (454D509G01 I X ua ls 2 Screws, steel, . 1 90-32 3 fur n1shed w1th front cover . 1 90-32 Top ( 2 holes) lock washers for secun n g to panel 8}-{i��'ffi---=��'"'-<t f an Base, breaker and mou n t i n g p l a t e 2 k 3 ·· �2 � �._I_ 2 .2. 16 - f-- 1 @ i 5 32 Standard Breaker Ampere ---- � -I 2 Special Breaker with Auxiliary Switch 13 13 � //l. �32 Breaker escutcheon and moun ling screws 2 - . 1 90-32 X 3 Base m o u n t i n g screws J.. 32 lec Critical d i mensions of stab and mounting c l i p Mounting of Front Panel Supported Bases (Side View) tri ca Single Base Surface Mounted (454D509G02) __..... 32 64 � Rating ar .l.....__l, slot lP Ampere rat1ng tM Two Breaker Base, Front Panel Supported (454D509G03) Mounting o f Surface Mounted Base (Side View) <i. Breaker escutcheon ww w .E Critical d i mensions of stab and mounting c l i p 3 64 !.? 3 Pole Handle Yoke (207B508H02)Cj . 234 --;-c- .--1::1 � -fi... 2 Pole Handle Yoke (207B508H01 ) Cj 2-. 1 90-32 Base mounting screws C9 Style number changed since previous issue. � long . 234 r---- 1 32 --------j �J . 1 95 15 _ _ _ _ CJj __ CJJ Technical Data 29-220 Page 7 October, 1 978 S u persedes Price List 2 9 - 2 20, pages 7 - 8, dated February 1 7, 1 969 Types A L B - 1 , N L B - 1 , 1 25 Volts Ac and De, 5 0 Amperes Maxi m u m, 5000 Am peres I.C. A B L-1 B reaker M o u nt i n g B locks, Continued 1 P h a se ( � x 1 Copper Bus not Supplied) A p p l ication in De a n d 1 P hase P a n e l s Bus Bar Drilling for De and ( 2 Separate Bases shown. Basic Pattern is 1 Molded Base Accommodating 4 Single Pole Breakers) an B u s bar C Busbor A P a n e ls Busbor A 3 Phase P a n e l A p p l i cat ion F o r Two B reakers per load C i rc u i t lP 454D509G04 Front View ar tM Stab Bose AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Mailed to: E, C/1 905/PL .c om 8 West i n g house E l ectric C orporati o n Low Voltage Breaker Division Beaver, Pennsylvania 1 5009 ( B asic Pattern of Three Separate Mou lded Bases can be Repeated for Longer Panel Boards) ca Bus bar 8 and stab bose .E lec tri Front View B us B a r D r i l l i n g f o r 3 P hase P a n e l s For Two Breakers per Load Circuit (� x 1 Copper B us not Supplied) Stab bose mtg screws I 2 Critical d i mensions of stabs and mtg.clips .190-32 Topped holes w Side View O u t l i n e D i mensions for M o u n t i n g Bases 454D509G04 o r 454D509G05 ww r- � Diameter 2 cou n t e r bores � deep a Dtometer _..--- - 6 1.4 2 holes Front Vtew .c om Tec h n ical Data 29-220 Page 8 D i mensions, Continued A L B - 1 B reaker a n d M o u nt i n g Block 1 Phase Panels (2 Separate Bases shown. Basic Pattern is 1 Molded Base Accommodating 4 S i ngle Pole Breakers) 1 Phase 1 Copper Bus not Supplied) Bus B a r D r i l l i ng for De and x ( '.4 454D509G08 BusbarC "1 329 <t_ j_ r_ 3 6 ' 64 : I ' -' Busbar A ....._ <t_ 31I6I 35 64 - --- -_2 _ L 2 �- T an .I....!-.:+:..-++-+-+- .190-32 Tapped holes � 2 I 3 Phase Panel A p p l ication 454D509G08 Stab base _ and mounting I 2 32 -f-H-t-----;-Jf-7 <t_ I 4 tM 454D509G08 Panels ua ls A p p l ication i n De a n d B u s B a r D r i l l ing for 3 Phase Panels For Two Breakers per Load Circuit ('.4 x 1 Copper B us not Supplied) For Two B reakers per Load C i rc u i t tri ca lP ar ( B asic Pattern of Three Separate M o lded Bases can be Repeated for Longer Panel Boards) lec 454D509G05 .E 6� Thick steel . 1 90-32Thd. � 8 usbarC B Side View ' 1- us bar B .190-32 / Tapped holes 3! t ' 1 2a7 2! .2 r 31 ' • � - - - - � ' 2 f* * 2 � Busbar A r O u t l i ne D i mensions for M ou n t i n g Bases ( S i d e View) ww w 454D509G0 5o r 454D509G08 O ut l i n e D i m e n s i o n s for M ou nt i ng Bases 454D509G05o r 454D509G08 454D509G05 .c om October, 1 978 S u persedes Price List 29- 220, pages 9 - 1 0, dated February 1 7, 1 969 Westi n g h o u se Electric Corporat i o n L o w Voltage B reaker D ivision Beaver, Pennsylvania 1 5009 Tec h n i c a l Data 29-220 Types A L B - 1 , N L B - 1 , 1 25 Volts Ac, De; 50 Amperes Maxi m u m, 5000 Amperes I.C. AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a i led to: E, C/1 905/ P L Page 9 A L B -1 B reaker M o u n t i n g B l ocks 3 Phase Panel Appl ication ( For One or Three Breakers per Load Circuit) an B u s Bar D r i l l i ng for 3 Phase Panel A p p l i cation For One or Three Breakers per Load Circuit ( !4 x 1 Copper B us not Supplied) us ba r B tM B ca lP ar Stab base and mig. scews O u t l i n e Dimensions for M o u nting Base 454D509G06 r � 2 32 ' 11: 31 64 6t R, oiameter 2hales 7 / "<.. � Diameter 2 counter bore s / � deep .E Handle pivot ct. Handle pivot ct. .'; Front View 1� Diameter megger holes if required Front Panel Cutout Breaker Load End ct. w ww 454D509G0 6 .190-32 Tapped holes 3 -- a O utline of Base ( S ide View) 454D509G 04, 454D509G05, 454D509G06, 454D509G08 "· -� tri --r. lec 3 8 I I I For 1 three pole circuit Load End For 1 Single pole circuit .c om Tech n ical Data 29-220 Page 1 0 � Characteristic Time- Current 4 2 Curve I 40 20 10 \ I--t-Characteristic Time- Current Curve f---fInstant aneous Tripping Occurs 320 Amperes or 20 Times Element Rating f---fMore Than Whichever is Less . . .050 Sec 800 Amperes Less Than .200 Seconds \ \ f:=� -, \ \ \ I " an � "-... I'.. 1'\. I'. ....... ......._ 1\ ' Minimum ....- 4 2 I" ..... I 6 4 4 Times Rated Current 5 6 7 6 9 10 20 C h a racteristic Tem peratu re Rating C u rve Line c; a: 0 E 0 z � 95 90 ./ 85 80 75 70 / 100 90 v / 80 70 v 60 / / Ambient Temperature, •c 50 40 30 20 .E � 100 ./ w Westinghouse Electric Corporation Low Voltage E}reaker Division Beaver, Pennsylvania 1 5009 ww ./ lec "' .: 110 105 / { { tri 1 15 50 70 W i r i n g D i a g ra m 125 120 30 " ..... 10 0 Load Type ALB-1 200 90 100 ca 2 tM 0 /" Maximum ar 0 r-.. 1\ lP 1'\. I 0 M I L- C - 1 7588 This specification incl udes the A L B - 1 type circuit breaker. It req uires that this breaker carry 1 1 5% of current rati ngs for more than one hour and that the primary elements i n i tiate tripping a t 1 38% rated current with i n one h o u r a n d at 200% i n 1 0 t o 1 00 seconds. A tripping characteristic of the primary element is based on the current flowin g through a l l poles i n series and i n a n a m bient of 5o· c. The minimum instantaneous trip setting shall be 320 am peres or 2 0 times the element rating, whichever i s less, and trip at not less than .050 second. At 800 a m peres the breaker must trip at . 2 00 second or less. ua ls { C h a racterist i c C u rves A L B - 1 Breaker C h a racteristic T i m e- C u rrent C u rve 300 1/ Draw Out Connection � Line 1 onary / Stati Connect1on � Load Type NLB-1 500 Types AOB-A 1 00, N O B -A 1 00, 250 Volts De, 500 Volts Ac, 1 00 Amperes M a x i m u m , 1 5,000 Amperes I . C . Trip u n its with c u rrent ratings o f 1 5, 25, 50, 7 5 and 1 00 can be q u ickly i nterc hanged and a conversion kit is available to change a 3 - pole, 500 volt AOB -A1 00 to a non automatic N QB - A 1 00 circuit i nterrupter. N O B - A 1 00 breakers have a maxi m u m con tinuous c u rrent rating of 1 00 a m peres, but they are used only as disconnects since there is no automatic opening device. A O B -A1 00 a n d N Q B -A1 00 B reakers an Note: A Q B -A1 00 and N O B - 1 00 b reakers a re sold for replacement o n l y . They a re no longer on Navy Qualified P roduct l i st . Specificati o n : M I L- C - 1 7361 1 5 - 1 00 Amperes 500 Volts Ac and 250 Volts De Two or Three- Pole tM Those breakers (and interrupters) designed for De motor c i rc u its and for Ac feeder cir cuits (designated with a " B F" i n amp rating column of price table) have fixed i n stan taneous settings of 600%-700% conti n uous c u rrent ratings. Those having a mag netic element set to trip at 1 200% - 1 400% are applied on Ac motor circu its. Breakers de sig nated with " B E" are cali brated for De appl ication. I nterrupting Rating 1 5,000 Amps Ac and 1 0,000 Amps D e lP ar AQB-A1 00 circuit breakers a r e designed for use i n l i g hting and distribution panelboards and switchboards for the protection of feed er a nd motor branch c i rc u its. Net P rices See Price List 29-020 H igh Two-Pole, 250 Volts De 1 5- B E 25-BE 50- B E 75-BE 1 00- B E 90 1 50 300 450 600 1 05 1 75 350 525 700 Two-Pole, 500 Volts Ae 90 1 05 1 80 21 0 1 50 1 75 300 350 600 700 900 1 050 1 200 1 400 Non-Automatic 1 764 1 764 1 764 1 764 1 764 676 677 678 679 680 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 681 682 683 684 685 686 687 688 1 05 1 75 350 525 700 1 764 1 764 1 764 1 764 1 764 689 690 691 692 693 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 694 695 696 697 698 699 700 701 702 703 704 .E 90 1 50 300 450 600 ww w 90 1 05 1 80 210 1 50 1 75 300 350 350 300 600 700 450 525 900 1 050 600 700 1 200 1 400 Non-Automatic National Stock N o . Style N u m ber National Stock No. . . . . . . . . · · · · · · · · 1 764 1 764 1 764 1 764 1 764 638 638 638 638 638 None None None None None Assigned Assigned Assigned Assigned Assigned 1 764 1 764 1 764 1 764 1 764 640 641 642 643 644 H5925-00-248-1 1 04 . . . . . . . . . . . . H 5 925-00- 248-1 1 08 None None None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned Assigned Assigned 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 638 638 638 638 638 638 638 638 None None None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned Assigned Assigned 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 645 646 647 648 649 650 651 652 ................ H5925 -00-629-0975 ................ H5925 -00-628-0695 H 5 925-00-248-1 078 H 5 925-00-248-1 082 ................ 1 764 1 764 1 764 1 764 1 764 639 639 639 639 639 H5925-00-25 8-2945 H5925-00-258-2945 H5925-00-258-2945 H5925-00-258-2945 H 5 925-00-258-2945 1 764 1 764 1 764 1 764 1 764 653 654 655 656 657 H 5925-00-608-0972 H5925-00-553-9745 H5925-00-383-381 4 H5925 -00-248-1 371 H5925-00-608-0973 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 639 639 639 639 639 639 639 639 639 639 639 H5925-00-258-2945 H5925-00-258-2945 H5925-00-258-2945 H 5 925-00-258- 2945 H5925-00 - 258-2945 H5925-00-258-2945 H 5 925-00-258-2945 H 5 925-00-258- 2945 H5925-00 - 25 8 - 2945 H 5 925-00-258- 2945 H 5 925-00-258-2945 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 1 764 658 659 660 661 662 663 664 665 666 667 668 H5925-00-502-671 9 H5925-00-248-1 453 H 5 925-00-21 5 -3758 H 5 925-00-248-1449 H 5 925-00-248-1442 H5925-00-51 8-5979 H 5 925-00-248-1436 H5925-00-248-1 437 H5925-00-248-1429 H5925-00-588-2453 H5925-00-699-1 1 1 1 . . ...... . . . . H5925-00-399-81 20 . . . . . . . . .. .. . .... . . ... . . . ' . H 5 925-00-399-81 27 Three-Pole, 500 Volts Ae 1 5- B F 1 5- B 25-BF 25-B 50- B F 50-B 75-BF 75-B 1 00 - B F 1 00 - B 1 00@ Trip Unit Only Style N u m ber Assigned Assigned Assigned Assigned Assigned Three-Pole, 250 Volts De 1 5- B E 25-BE 50- B E 75-BE 1 00 - B E A O B - A1 00 None None None None None lec 1 5- B F 1 5- B 25- B F 25-B 50-B 75-B 1 00 - B 1 00@ I National Stock No. ca Low Breaker Frame Only@ Complete Breaker@ Style Number tri Instantaneous Trip Setting in Amperes AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a i led to: E, C/1 905/ P L Cont. Ampere Rating Tec h n i c a l Data 29- 220 Page 1 1 October, 1 978 Supersedes Price List 2 9 - 2 20, pages 1 1 - 1 2, dated J u ly 1 , 1 97 4 .c om 8 Westi n g house Electric C o rporat i o n Low Voltage Breaker Division Beaver, Pennsylvania 1 5009 ... . . . . . .. . . .... . .. . . . . . . . . . H 5 925-00-658-9609 H 5 925-00-265-9474 . . . . . . . . . . . . . . . . H5925-00-396-2339 . ..... ..... . . .. . H 5 925-00-396- 2345 . . . . . . . . ... . . . H5925-00-396-2352 H5930-00-259- 9440 . . . . . . . . . . · · · · · · . . . . . · · · · · · · · · · · N ote: B reakers with ratings other than those g iven o n this page are considered special and full description data must be provi ded . @ Styles listed include sli p-type connectors for rear connections. Order front termi n a l connectors separately if required. No additional charges for front connectors ordered with breakers or frames. @ Type N Q B -A1 00 non-automatic. To convert 3-pole AQB breaker to NOB breaker. order style 1 764 668 only. .c om Cl Technical Data 29-220 Page 1 2 Front C o n nected B reakers For the load ends of panel board breakers and for other front terminal appl ications, pressure connectors should be ordered. Prices given below apply only when connectors are ordered separately. When breakers and the requi red l ugs are ordered simultaneou s ly, these lugs will be su pplied without charge. N3-N14 N23-N40 N50-N75 I I N avy Cable Size, Max.@ 1 4,340 3'8,91 0 75,780 @ Circular mils area. I I I Description I One Pressure Connector One Pressure Connector One Pressure Connector I Style N umber I 1 763 660 1 763 661 1 763 662 National Stock N o . F u n g u s - M o i st u r e R e s i s t a n t T r e a t m e nts: (Jan -T- 1 52, J a n - C - 1 73 or M I L-V1 73 ) if specified, contact Westinghouse. External parts are coated; trip u n its are not treated. None Assigned None Assigned None Assigned Description Style N umber National Stock No. 2 3 2 or 3 M o u nting Mounting Mounting One Stud 1 764 1 764 1 764 1 631 None Assigned None Assigned H 5 940-00-643 - 7 1 94 H5940-00-501 - 9 1 20 ca lec .E w ww Tri p U n i t 2 - Pole AOB 2 - Pole N O B 3 - Pole AOB 3 - Pole N O B lP C o m p l ete B reaker 2 - Pole A O B 1 0.00 8.75 2 - Pole N O B 3 - Pole AOB 1 0.75 3 - Pole N O B 9.50 tri N et Weight, Lbs. Ter m i n a l M ou n t i n g S u p ports ( Set of Two ) Frame 2- Pole Mounting 2 - Pole AOB - 7.375 Block Assembly 2.75 2 - Pole N O B - 7.375 3 - Pole M o u nting 3 - Pole AOB - 7 .875 Block Assembly 3.25 3 - Pole N O B - 7.875 ar N umber Poles 675 674 240 442 S p a re Parts Boxes: Per M I L - B - 233: After determining box size o r n u m ber of spare trips to be stored therein, contact Westi nghouse for quotation. Tec h n ical M a n u a l N avships 362-081 9p e r M I L- M -1 5071 : When req u i red, specify I B - 29-062-CIA. tM Switchboard M ou n t i n g Com plete breakers and frames incl ude mou nting hardware. Female slip connectors are mounted i n the breaker base for plugging onto stud projections of terminal mounting block assemblies. Order one m o u nting block assembly for each end of the breaker. Block Assembly Block Assembly Block Only Assembly - Complete with 4 N uts M e c h a n i c a l I nterlock: When a mec han ical i nterlock (switchboard use) is desired for a pair of breakers. Order by description. ( N ot submitted for Navy a pprova l ) . an Cable Range Additions H a n d l e Lo c k : When specified, order style 1 6 1 4 485. One furnished without charg e p e r every 1 0 breakers, w h e n requested. ua ls A Q B -A1 00 a n d N Q B - A1 00 B reakers, Continued - 2.625 - 1 .3 7 5 - 2.875 - 1 .625 I n d i v i d u a l R e p roductions: When re q u i red, reproductions of master drawings, outline drawings and certification sheets can be ordered as follows: Item 2 3 4 5 Description F u l l size photo lithic tracing of master drawing on cronoflex ( mylar) O utline and drilli ng plan on c rone flex (mylar) Certification data on cronoflex ( mylar) Van Dyke negatives of items 1 or 2 Reproductions of Items 1 , 2, or 3 D rawings Ava i l a b l e : M aster drawing 1 - J F - 630; rear con nected breaker outline, d ri l l i ng and wiring diagra m 20- B - 2881 ; front connected breaker outl i ne, d r i l l i n g a n d wiring diagra m 30- B - 3837. 400 Cycle B reakers: R efer house. to Westi n g Tech n ical Data 29-220 Page 1 3 October, 1 978 S u persedes Price List 29- 220, pages 1 3 - 1 4, dated February 1 7, 1 96 9 Types AQB -A1 00, N QB -A1 00, 250 Volts De, 500 Volts Ac, 1 00 Amperes Maxi m u m 1 5,000 Amperes I . C. AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Ma iled to: E, C/1 905/ P L tM an O u t l i n e D i mensions AQB-A 1 00 a nd N Q B - A 1 00 Breakers ar 8 Visable a m p ratmg interchangeable D r i l l i ng P l a n lP trip u n 1t F r o n t Cover C u t o u t 11 8 - Min.slot �Rod. m1n ww w .E 16 lec 15 Load End tri ca For Mou nting Panel ( Front View) .c om 8 Westi n g house Elect r i c C o rporat i o n L o w Voltage Breaker Division Beaver, Pennsylvania 1 5009 hole lor handle lock and 098 Dta. Mounttng bolls and washers (furnished with termmal blocks) (4) i-20xl� L G S l otted hex hd s bolts For 2·pole bkr center pole current carrymg parts are omilled .c om Cl Tech n ical Data 29-220 Page 1 4 20 <f> <1) c <1) E fCC 1\ 5 4 3 2 \ � Tri p at 600% to 700% Ratmg I \ \ 10 � -- Instantaneous \ 0 I I I <f> "D c 0 u <1) (f) I I ro � l\1\\. 1 Percent Rated Current " 0 II 0 N U' U' / 400 1000 ' v N 0 / v '/ 200 0 0 0 0 0 0 0 lO Cl) 0 I I O perat i n g C h a racteristics Trip U n it Rating 1 5 - 1 00 Amperes 50oC Ambient - Cold Start, 60 Ac or De � - - rI- - 300 0 I I 0 0 <t U' N , , 0 0 300 1 5 00 I I 0 0 r<l "' 800 ' 0 0 N - 60 0 '\. 0 0 1 00 � 20 0 Max1mum 5 4 3 2 �� 6 N VJ U1 ro 0. Mm1mum 40 30 20 15 10 - 0 0 0 0 en o N 0 0 0 r<J U' "' 0 0 61- N U' " 1-- Operating Cha racteristics Trip U n it Rating 1 5 - 1 00 Am peres 50°C Ambient - Cold Start 400 Cyc l e Ac Tri p U n i t R a t i n g 90 Cycle, 80 70 I II ca 60 50 40 30 tri 20 c " 10 -� .E lec :0 E <( ww w Westing house Electric Corporation Low Voltage B reaker Division Beaver, Pennsylvania 1 5009 Specification M I L- C - 1 7361 This specification covers all therm a l - ma g netic AQB breakers. It requ i res t h a t they carry 1 50% of current ratings for at least one hour and that thermal ele m e nts i n itiate tri pping at 225% rated cu rrent within one hour and at 600% i n 2 5 seconds plus or minus 25%. The instanta neous mag netic settings for each conti n uous ratings are based on i ntended appli cations. (Therm a l tripping tests are conducted with a l l poles i n series i n 50°C ambi ent; each pole i s tested ind ivid ually to check mag netic settings.) tM \ 0 0 Hours ar 1 � Seconds an - - - I nstantaneous Tri p at 1200% to 1400% Rating 40 30 "' 400 Cycle B reakers lP :J 0 :r: t' 5 4 3 2 ua ls C h a racteristic C u rve A Q B -A1 00 B reakers 0.5 Foetor 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 To determ ine the tri p u n it rating to be used, when the load current and a m bient are known, m u ltiply the load current by the factor obtained from this curve for the known a m bient. The result will be the ideal trip u n it rati n g . H owever, since trip u n its are furnished only with standard ratings as per N avy spec., select the standard trip unit whose rating is equal to or one rating hig her than the ideal rati n g . Tec h n i c a l Data 29-220 Page 1 5 � � � A O B -A1 01 a n d N O B - A1 01 B reakers S pecification : M I L- C-1 7361 1 5- 1 00 Amperes 500 Volts Ac and 250 Volts De 3-Pole an tM N O B - A 1 0 1 circuit breakers have a maxi mum conti nuous cu rrent rating of 1 00 a m peres. They a r e used o n l y as discon nects, since they do not i nclude an automatic opening device. AOB -A1 0 1 circuit breakers are designed for use i n lighting and distribution panelboards and for switchboards i n the protection of feeder and motor branch circu its. I Net P rices See Price List 29-020 AOB-A101 AOB-A1 01 AOB-A1 01 AOB-A101 AOB-A101 AOB-A1 01 1 5 H Amp 2 5 H Amp 50H Amp 7 5 H Amp 1 00H Amp 1 00 G H Amp Hi National Stock N u m ber M a g netic Only Style National Stock N u mber 458D509G 1 1 458D509G 1 2 458D509G 1 3 458D509 G 1 4 458D509G 1 5 4 58 D 509G 1 6 458D509G20 H 5925-00-876-921 6 H 5 925-00-876 -921 7 H 5925-00-876-921 8 H 5925-00-876-921 9 H 5925-00-876-9220 . . . . . . . . . . . . . . . . . . . 458D51 1 G 1 1 458D51 1 G 1 2 458D51 1 G 1 3 458D51 1 G 1 4 458D51 1 G 1 5 ........... None None None None None None None Assigned Assigned Assig ned Assigned Assigned Assigned Assigned 458D5 1 0G 1 1 458D 51 0G 1 2 458D51 0G 1 3 458D51 0G 1 4 458D51 0G 1 5 4 58 D 5 1 0G1 6 H 5925 -00-867-7328 H 5925-00-867-7329 H 5925-00-986-731 3 H 5925-00-986-731 4 H 5 925 -00-972-3000 . . . . . . . . 458D51 2G 1 1 458D51 2 G 1 2 458D 51 2 G 1 3 458D51 2 G 1 4 458D51 2 G 1 5 None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned lP I Lo 1 80- 2 1 0 300- 350 600- 700 900-1 050 1 200-1 400 1 200-1400 N o n-Automatic 75-1 05 1 25 - 1 7 5 250-350 375-525 500-700 500-700 . .. . . · · · · · · · · · · · · · · · · · · ...... . . · · · · · · · . . ...... .... . . . . . . . . . . . . .. . . . . .. ... @ Instantaneous trip setting at 1 200-1 400% H i o r 500-700% Lo. Set at Lo position at factory. ® Complete b reaker does not include mounting bases. Type required must be ordered separately. @) Front connected bases include cable lugs. Cover cable sizes 2 8 2 8 C M to 1 OO,OOO C M . @ Only 3 -pole breakers are furnished. f o r 2 - p o l e applications make connections t o outside poles. lec AOB-A101 Thermal Magnetic Style ca 400 Cycle 1 5 Amp 25 Amp 50 Amp 75 Amp 1 00 Amp 1 00G Amp 1 00 Amp tri AOB-A101 AOB-A1 01 AOB-A101 AOB-A1 01 AQB-A101 AOB-A101 N O B -A1 01 Instantaneous Trip Settin g @ Ac 60 Cycle ar Test Report N u mber: 541 9-43. These breakers have adjustable i nsta nta n e o u s trip settings o f "lo", "intermediate", ! • and "hi". The "lo" setting is 500%-700% of continuous c u rrent rating. It is designed for D e motor circuits and Ac feeder circuits. The "hi" setting is 1 200%-1 400% of conti nuous current rating and is designed for applica tion on Ac motor c i rcuits. The i ntermediate setting may be used to in crease l o setting trip a m peres or decrease h i setting tri p a m peres as m a y b e req u i red. I nterrupti n g R a t i n g 1 5,000 Amps Ac and 1 0,000 Amps De N o n - I nterchangeable Trip Unit Class: H i Shock M I L- S - 9 0 1 : 50°C Ambient Trip Unit Rating AB DE IQN® Circuit Breakers for Naval Shipboard Use ua ls M a iled to: E, C/1 905/ P L Type@@@ � Typ es AO B -A1 01 250 Volts De, 500 1 00 Amperes Maximum, 1 5,ooo Amperes 1.c. October, 1 978 Su persedes Price List 29- 220, pages 1 5- 1 6, dated J u ly 1 , 1 974, and S u pp. page 1 6 . 1 dated August 7, 1 978. .c om Westi n g house Electric C o rporat i o n L o w Voltage Breaker D ivision Beaver, Pennsylvania 1 5009 · · · · · · · · · · · . . · · · · · · · · · P a n e l bo a rd M o u nt i n g Type ww w .E Single Base Front Connected Single Base Rear Connected Single Base, Rear Connected, Line Front Connected, Load For use with rear connected fuse base Double Base Front Connected Double Base Rear Connected Style N u m ber Weight National Stock No. 31 5C364G03 31 5C364G02 2.75 Lbs. 3.00 Lbs. None Assigned None Assigned 31 5C364G04 458D569G02 458D569G03 3.00 Lbs. 3.50 Lbs. 4.00 Lbs. None Assigned None Assigned None Assigned AOB-A101 Breaker with Single Front Connected Base AOB-A101 S i ngle Mount ing Base - Rear Connected AOB-A101 Double M o u nt ing Base Front Connect ed .c om Technical Data 29-220 Page 1 6 Fuse U n it Asse m bl ies I Complete Fuse U n it Assembly Front Rear Front Rear 1 5-25 Amps 1 5-25 Amps 50, 7 5 , & 1 00 Amps 50, 7 5 , & 1 00 Amps I Shipped As: Fuse U nit@ Type AOB- F 1 0 1 A AOB- F1 01 A AOB- F1 01 B AOB- F 1 01 B Fuse Unit M o unting Base Style Number Style Number 504C01 0H01 504C01 0H01 504C01 0H02 504C01 0H02 655D258G01 @ 655D258G05@ 655D258G03 655D258G06 w .E lec tri ca lP 372 B 1 55G01 372B 1 55G02 372B1 55G03 37281 55G04 Connection Rating ar Style N umber tM an ua ls AQB - F 1 0 1 A a nd AQB - F 1 0 1 B fuse u n its are designed for use in conju nction with standard A Q B - A 1 0 1 circ u it breakers on circu its where a fault potential of u p to 1 00,000 amperes exists. ww ® Individual fuses are not replaceable; replace with complete unit. @ To convert for use with high rating fuse unit (AQ B - F 1 01 B ) i n field, remove rejection pin per i nstructions o n fuse unit mounting base nameplate. Tech n ical Data 29-220 Page 1 7 Types AQB-A1 01 , N Q B -A1 0 1 , 250 Volts De, 500 Volts Ac, 1 00 Amperes Maximum, 1 5,000 Amperes I . C . October, 1 97 8 S u persedes Price List 29-220, pages 1 7 - 1 8, dated J u ly 1 , 1 97 4 Shunt Trip Breaker Type Style Number Shunt Trip - Volt age and Fre quency 4976D65G06 4976D65G02 4976D65G08 4976D65G04 1 20/60 1 20/Dc 1 20/60 1 20/Dc Thermal Magnetic Thermal Mag netic Magnetic Only Magnetic Only an tM I n d i v i d u a l Re prod ucti o n s : When req u i red, reproduction of master drawings, outl ine drawings and certification sheets can be ordered as follows : Item Description 1 Full size photolit�ic tracing of master drawing on cronoflex (mylar) Outline and drilling plan o n cronoflex (mylar) Certification data on Cronoflex (mylar) Van Dyke negatives of items 1 or 2 Reproductions of items 1 , 2, or 3 2 3 4 5 Net Weig hts, Lbs. AQB-A 1 01 - 6.00 N Q B -A1 0 1 - 5. 7 5 AQB - F1 0 1 A - 2.00 AOB - F1 0 1 B - 2.00 Fuse U n it M o u nting Base - 3.00 ca A u x i l i a ry Switch: Breakers can be sup plied with interna l ly mou nted a uxiliary switch to open or close control c i rc u its as breaker operates. Each switch provides one "A" contact and one "B" contact. "A" con tact is closed when breaker is closed , open when breaker is open. "B" contact is open when breaker is closed and closed when breaker is open. When ordered with one switch it is normally mou nted i n right pole, may be specified mounted i n left pole. A maxi m u m of 2 switches can be supplied: one i n left a nd one i n right pole. Order by description. � ar To order, specify style n u mber of standard breaker req u i red plus style n u m ber of s h u nt trip attachment from table below. ( M ust be factory insta l l ed . ) D rawings A va i l a b l e - 900J429 - Master d rawing for breaker and mounting bases. 900J439 - M aster drawing for breaker with fuse u n it and mounting bases. 459 D448 - Outline and wiring diagram for breaker on single base. 654D255 - Outline and wiring d i agram for breaker with fuse u n it on single base. 459 D449 - O utline and wiring d i agram for breaker o n doubl e base. 654D256 - O utline and wiring d i agram for breaker with fuse unit o n double base. 6 5 7 D 20 5 - For fuse u n it mounting base only. lP Additions Shunt Trip: B reakers can be equi pped with a s h u nt trip attach ment for tri pping the breaker from a remote point, and can be supplied with coi l s for 1 20 volts, 60 cycle or for 1 20 volts De. These s h u nt trips have momentary rated coils a nd are supplied with an auxiliary switch to be wired i n series f o r protection (Auxiliary switch i n c l u ded with t h e shunt trip. Do n o t order separately) . O rdering I nformatio n : See page 4 . tri lec .E N ote: One a u x i l iary switch normally sup plied with shunt trip attachments for cut- off switch a nd additional switches can not be suppl ied on breakers with s h u nt trips. H a n d l e Lock: When specified, order style 1 61 4 485. Rear Stud: Complete with 4 nuts, styl e n u mber 208B801 G01 . w F u n g us- M o isture Resista n t Treatment: (JAN -T-1 52, J A N - C- 1 73 or M I L- V- 1 7 3 ) . I f specified, contact Westi nghouse. External parts are coated. ww Tec h n ical M a n u a l : Navships No. 36223 1 4. This booklet per M I L- M - 1 507 1 . When required, order BV R -T M -475A. AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a i led to: E, C/1 905/ P L .c om Westi n g house E l ectric Corporat i o n L o w Voltage Breaker D ivision Beaver, Pennsylvania 1 5009 .c om Technical Data 29- 220 Page 1 8 O u t l i ne D i mensio ns, A Q B - A 1 0 1 B reaker For S i ngle Breaker Mo unted Base 5ffi I r' an 6 12 ua ls Single Breaker ( R ear Mounted) Copper extensions for megger read ings. Copper extensions 14----- can be broken off 2� 8 : • 3 \@6 tM m ate - \9 32 ar f :�\ D r i l l i ng P l a n F o r Single M o u nted Base C i rcuit B reaker H a n d le Locking Device lP Reverse position of lock to b<"k" f.omopMI"g % 1 Dia. megger OFF test holes ( Not supplied with circuit Westinghouse style .E lec tri ca Breaker outline ww w ������� 3\6[? 9 132 �--�----�---+- �--�----�� ___1 .098 Dia. hole for handle locking device or warning tag bkr.) 1614485 Types AQB -A1 01 , N Q B -A 1 01 , 250 Volts De, 500 Volts Ac 1 00 Amperes M aximum, 1 5,000 Amperes I . C. A Q B - A1 01 B reaker M o u nting B locks For Double Mounting Front Con nected For Two Breaker Mounting Base Between ct_of next base 8 r--l - -1�8: •fo--- 1�8+1 I l � ·-- 3 rl 4� \1:+-��tJ:HJ,+1�� t "j= -(:�,: - ! I-f"��o' - �- - . .---- l i...I. .H -r+--+---1-- w 9) -- ��: 48 --· - . H�I . . � �'"' - · -1 - 1 32 4 - 1� i · �D l� j? 1 3, 3 - -- Load ';;_ r:r I .E w ww __ �= ���at I.. 1 · .. .C ! I ·I - 1�!1;f1 JillI I' _ Frant caver I Pivot l ine I I 1 3 34 i'�:I ' ," '-'1 ' c� L - J_ � l___l_ . 1 90 32 X - L "T i[L j "1,1 . ! _ _ : l _ r- 1 , r- 1 1 4- Dia. · Round head screw 16 Max. width · max. , an d 2I m ·r� \- thick copper ., bus 1 - ..,*F �h' '-- � T -1 c _, · r � l.l- - - -· � - f� J;- � C bore ( 6 hales) Front Cover Cutouts For Double Mounting Base 11 ,k... � 5 32 9 oia. mtg. hale 32 ' ·I� --- I .I -F=--l;l lec r;;;;_ "'{:"' ��!. '-, - - •-+-+7f(+t+---'- 4-1 - 20Tap -� �r ( 2 hales) c :c- r -!J �f��=�=l [l _ I. _ l ·l t I !:_� _ll r-�� �===+t- ��i� ca ll .. � l I - -� - - . t;�� ::� L --�� 6 :f2 -- · tri C 1 r 7 rTI 1 f .-_)if� 4-20Tap -: f. ( 2 holes) -.--r'-+-+-+-+ 1 �--c---+-«a+1�4 ..== � I 1== --. ,. -1 - ' ""' r:-21 t_4-1 '-48 1 I "�' r l . I I ,-,-, tC:' ""'"'l'""" 31 + X./ � Thk. lnsulatian recommended . 13 . . Dnl l 32 mm. dla. holes s! ---'---+ 1_ 3 , ( not furnished) .l � - 8 j II � e�� � ��� e� ·� �� / [ 32 .-�.--�-H-------�'� - � ,� -r�r -s r _, I 1 3 r-2 - tM �' � 6j, --- 6a --f---.1 � ...-��·-- -� ar 1r �i6 8 _ Capper extensions for megger readings lP , 3 __.. For Double Mounting Rear Connected an 4 AB DE-ION® Circuit Breakers for Naval Shipboard U se ua ls M a i led to: E, C/1 905/ P L 1 Technical Data 29-220 Page 1 9 October, 1 978 Su persedes Price List 29- 220, pages 1 9 - 20 dated February 1 7, 1 969 .c om 8 West i n g h o u s e Electric Corporation Low Voltage B reaker D ivision Beaver, Pennsylvania 1 5009 [ -· I. Complete hardware supplied except for capper bus bars 1 I "'= T,1. ___ �� ·�tf'- v h�l�"l�� f-:" _ _ M bolt I.J38_. - Mounting plate _I _ Cable entrance Complete hardware supplied except far capper bus bars .c om Technical Data 29-220 Page 20 O u t l i n e D i m ensio ns, Continued A O B -A1 01 F B reakers, S i n g l e Base with Fuse U n it For M o u nting of B reaker ( Front Connected) Copper extensions for megger readings ( may be broken off if not required ) LSE 52 4�--v 23 32 Max. across corners .J T-·n l - an - For Dimensions of Breaker and Mounting Base See Drawing Number 459D448 ua ls 2 16I For M o u nting of Breaker ( Rear Con nected) 1 I iL _'-':==--'---rl ::,__. -tl-c.._ ----'J_, j 8 Insulation sheet ( not supplied ) .,� lP ar tM - : ��-, + ca Terminal for M i nimum N avy Cable Thfa-3-2828 C. M . and Maximum Navy Thfa-1 00-1 00,000 C. M . r tri D r i l l i n g Plan For Rear Connected Studs and M o u nting Bases lec .E w ww Front Panel Cutout I� IS I - ---t-----ffi- �-20 Tap (6 holes) for mounting bases \ �l � _ _ I I 6 1- _.. - =-=r- -� , ----: - --+==� 1+--- 916 ____ 5 o ta. · megge r ( 3 holes) 2�4 -- i-3P2 16 9 i6 · r- l r--- -----I I :---- ( " \... _ - . I , _ _) ' ---- - r-- l-14.!, -:--- 2� -- � l j _ _ - �ker outline B .,.t '! t 1 j_ l .3 \ zi 1- � <t_of Breaker Tech n ical Data 29- 220 Page 2 1 October, 1 978 S u persedes Price List 29-220, pages 2 1 - 22, dated February 1 7, 1 969 Types AOB-A1 0 1 , N O B -A 1 0 1 , 250 Volts De, 500 Volts Ac 1 00 Amperes Maximum, 1 5,000 Amperes I . C. AOB-A1 01 B reaker, D o u ble Base with Fuse U n its ffir � h;f For Mounting of Two Breakers ( Front Connected) r(fl jj j 1 2! '"TI � I - ���� d � cY1ttr;0 -32 1 b====l====i � 13 � AQB-FIO I A or AQB-FIOIB n serts ( 2 ) .I for fuse puller screws 6u16 @ 20 t-"=-1 = '---;���== ;= -'==r���-=-.=::::i ,l�-'�f;_�J��. L c: t� -� � -- -- -- ---- -- -p- I4 For Dimensions of Breaker and Mounting Base See Drawing N u mber 459D449 an i.'.1 '. . 4 (' -1+_,f.J 2� � " FeTJUrr: rn u rre 1� Thick Insulation recommended tM -�-�'"""' .1.1..� � For Mounting of Two Breakers ( Rear Connected) 13% 1 15� ar �-(s-R� 33 ! 6 l 4�1� t---61..!,.�--"'" 1 1-- � 3�1 , iS i � �- .,�.-=... ----------- ----- - --- r .r � ,_ 1 11 ; :� �-- :::::�' J:j� � 7� I K- jto. f---r--+-1�--Ht-.r--+-r cc p L I lP 6 f 2� ! C::: AQB-AIOI c .r 6 6l ca 10 _-_-_-_-_- c c � � I _ I I tri AOB- FIOI A or AQB-FIOIB AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a i led to: E, C/1 905/PL .c om Westi n g house E l ectric Corporation Low Voltage Breaker D ivision Beaver, Pen nsylva nia 1 5009 h ----- : p u 2 93IT2 I ;)�JI ,, u '='=- , . •JP--'-- I �-�J�Il; l � I � Terminal for M i n imum Navy Cable Thfa-3 -2828 C.M. and Maximum Navy Thfa - 1 00 - 1 00,000 C . M . � 2� lec -------=-=--------19 � -----+1• 406 Min.dio . ( 6 holes) for 1 rear connected stud 1+----- 9� -------1 7 15 Bose outline 8 .E D r i l l i n g Plan For Rear Connected Studs and Mounting Bases w ww 43 32 � � 2 II ! F ront Panel Cutout .250-20 Top ( 10 holes ) for mounting bases 1I 2 II f-- i ,., _ L_J 6 - 9 ,. '- 2 4- 6169 16 . - , _ ..) ,. . '- · _ ..) i-- 2 1� -� �a +la ·1-- 21� � 16 ,- , - 16 :.I � reoker outline II �"- 32 l 1 I i � ::::-,. 1 ,11 14 1 3 t_ 1 � ii I� 3 1� Diameter megger 16 ( 6 holes ) .c om Technical Data 29-220 Page 22 400 Cycle B reakers V> (]) ::; ::;;: .S (]) E f= !\ \ \ ' ' 10 1\ 5 4 3 2 V> u (]) ({) -- Instantaneous Tri p at 500% to 700% Rofmg "' � ' ' 2000 �" $2 N 0 0 0 0 r0 7 Percent Rated Current 0 0 0 0 0 0 (j) Cl) 2 O perating C h a racteristics Trip Unit Rating 1 5 - 1 00 Amperes 50"C Ambient - Cold Start, 60 Ac or De, Thermal Magnetic 0 0 0 0 0 0 � � � Cycle, 0 0"'0 0 0 - N 1- - """ v v v IJ "' "' N V' +> I- "' 0 I :; Operating C h a racteristics Trip U nit Rating 1 5- 1 00 Amperes 50"C Ambient - Cold Start 400 Cycle Ac, Therm a l Mag netic Trip U nit R ating 90 I I 80 70 60 " tri 1.5 2.0 2.5 \)\ 1 40 30 20 15 10 � 5 4 3 2 [\ ) :I 0 0 N 0 0 0 0 r0 7 Percent Rated Current 0 00 0 0 0 t.O ro 9 50° C Ambient Cold Start, "G" rating, 60 or 400 Cycle Ac, or D e - Thermal Magnetic 3.0 3.5 4.0 4.5 Foetor To determine the trip unit rating to be used, when the load c u rrent and ambient are known, m ultiply the load current by the fac tor obtained from this c u rve for the known ambient. The result will be the ideal trip unit rati ng. H owever, since trip units are fur nished only with standard ratings as per Navy spec., select the standard trip unit whose rating is eq u a l to or one rating higher than the ideal rati ng. lec .E ww w Westi nghouse Electric Corporation Low Voltage B reaker Division Beaver, Pennsylvania 1 5009 1.0 "' " -- Instantaneous Tri p at 500% to 700% Rating \ \ 2 10 0.5 E "' \ i\ \j\ 0 I 20 (]) - - - I nstantaneous Tn p at 1200% to 1400% Rating 1 40 0 1 40 30 20 5 :s u 1/ 5 4 3 2 3 2 (X ca 50 netic AOB breakers. It requ i res that they carry 1 50% of cu rrent rati ngs for at least one hour and that thermal elements i n itiate tri p p i n g at 2 2 5 % rated c u rrent within one h o u r a n d a t 600% i n 2 5 seconds p l u s o r minus 25%. The instantaneous magnetic settings for each continuous rati ngs are based on in tended applications. {Thermal tri pping tests are conducted with a l l poles in series i n 5 0 " C ambient; e a c h p o l e is tested individ ually to check magnetic settings.) G e nerator B reakers � 3000 i 0 0 400 1 5 00 ll 'l N V' I/ 300 1 00 0 5 4 3 2 0 0- 60a \. 20 15 10 0 0 800 ' "' U' N i -" 0 1\[\ 40 30 " c 0 0 6 U' an 1 40 30 20 - - - I nstantaneous Tri p at 1200% to 1400% Rating N V' tM ' 2 - ar ::J 0 Specification M I L-C-1 7361 � This specification covers all thermal mag lP � 0 I 5 4 3 T1me, M1nutes Seconds AOB-A1 01 B reakers ua ls Characteristic Curves l' 0 0 0 0 "' 0 - N 0 0 0 r0 Types AQB -A250, N QB -A250 250 Volts De, 500 Volts Ac 250 Amperes M ax i m um, 20,000 Amperes I . C . A Q B - A250 a n d N Q B -A250 B reakers Specificati o n : M I L- C - 1 7361 1 25-250 Amperes 500 Volts A c and 250 Volts De Two and Three-Pole , tM AQB -A250 breakers can be ordered with u ndervoltage release devices, a u x i l iary switches and shunt trip attac h ments com plete with auxil iary switch. These attac h ments are a l s o easily i nsta lled i n t h e field. Test report n u mber 541 9 - 29. N et Prices See Price List 2 9 - 020 High Low H ig h _ Complete Breaker® Style Number Two-Pole 500 Volts Ac, 250 Volts 650 1 950 650 1 950 650 1 950 225-N 225- N M 250-N 2 50 - N M 250@ 650 1 300 1 500 3000 650 1 300 1 700 3400 N o n-Auto 1 1 300 3900 1 300 3900 1 300 3900 1 650 2250 650 2250 650 2250 1 300 4 1 00 1 300 41 00 1 300 41 00 31 3C682G03 31 3C682G04 31 3C682G05 31 3C682G06 31 3C682G07 31 3C682G08 None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned 650 1 300 1 770 3550 650 1 300 1 850 3800 Non-Auto 31 3C682G09 31 3C682G 1 0 31 3C682G 1 1 31 3C682 G 1 2 31 3C682G31 None None None None None Assigned Assigned Assigned Assigned Assigned 1 De 1 1 75 2350 1 950 3900 . . . . . . . . . . . . . . . . . . . . . . . . 650 1 300 31 3C682G 1 3 31 3C682G 1 4 31 3C682G 1 5 Three-Pole 500 Volts Ac, 250 Volts 650 1 950 650 1 950 650 1 950 1 300 3900 1 300 3900 1 300 3900 225-N 225-NM 250-N 250- N M 250@ 650 1 300 1 500 3000 630 1 300 1 700 3400 Non-Auto w 1 ww 1 1 75 2350 1 950 3900 . . . . . . . . 1 I 4520370G01 4520370G01 452D370G01 4520370G01 452D370G01 4520370G01 None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned 452D370G01 452D370G01 4520370G01 4520370G01 4520370G03 None None None None None Trip U n it Only Style Number National Stock No. 452037 1 G 03 4520371G04 4520371 G05 4520371G06 4520371 G07 4520371 G08 None None None None None None Assigned Assigned Assigned Assigned Assigned 452037 1 G09 4520371 G 1 0 4520371 G 1 1 4520371 G 1 2 29B271 0G05 H 5925-00-064-7834 None Assigned None Assigned None Assigned None Assigned 4520370G01 4520370G01 4520370G01 None Assigned None Assigned None Assigned 4520371 G 1 3 4520371 G 1 4 4520371 G 1 5 None Assigned None Assigned None Assigned Assigned Assigned Assigned Assigned Assigned Assigned De None Assigned None Assigned None Assigned 31 3C682 G 1 8 31 3C682G 1 9 31 3C682G20 31 3C682G21 31 3C682G22 31 3C682G23 None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned 4520370G02 4520370G02 4520370G02 4520370G02 4520370G02 4520370G02 H 5 925-00-789- 37 1 8 H 5 925-00-789-371 8 H5925-00-789-371 8 H5925-00-789-371 8 H5925-00-789-37 1 8 H5925 -00-789-37 1 8 4520371 G 1 8 4520371 G 1 9 4520371 G20 4520371 G 2 1 4520371 G 2 2 4520371 G23 None None None None None None Assigned Assigned Assigned Assigned Assigned Assigned 650 1 300 1 770 3550 650 1 300 1 850 3800 Non-Auto 31 3C682G24 3 1 3C682G25 31 3C682G26 31 3C682G27 31 3C682G36 None None None None None Assigned Assigned Assigned Assigned Assigned 4520370G02 4520370G02 4520370G02 4520370G02 4520370G04 H5925-00-789-371 8 H5925-00-789-371 8 H 5 925-00-789-371 8 H 5925-00-789-371 8 None Assigned 4520371 G24 452037 1 G25 4520371 G 26 4520371 G27 29B271 0G06 None None None None None Assigned Assigned Assigned Assigned Assigned 4520371 G28 4520371 G29 452037 1 G30 None Assigned None Assigned None Assigned 1 Three-Pole 500 Volts Ac, 250 Volts 1 00 - N G 1 60 - N G 250-NG 1 National Stock N o . 1 300 4 1 00 1 300 4 1 00 1 300 41 00 650 2250 650 2250 650 2250 .E 1 25 - N 1 25 - N M 1 50-N 1 50 - N M 1 75 - N 1 75 - N M 1 Style Number G enerator Circuit Breaker Applications lec Two Pole 500 Volts Ac, 250 Volts 1 00 - N G 1 60 - N G 250-NG De National Stock N o. tri 1 25 - N 1 25 - N M 1 50-N 1 50 - N M 1 75 - N 1 75 - N M I Breaker Frame Only@ lP Low De ca I Ins!. Trip Setting - Amps Ac ar AQB -A250 circuit breakers are used pri marily to protect feeder ci rcu its, however, those followed by " " N M"' in the price table have higher magnetic setti ngs to a l l ow for motor starting. Breakers with setti ngs spe cifically for use with generators are desi g nated " N G " i n the price table. an These breakers a r e available w i t h i nter cha ngeable trip u n its i n ratings of 1 25, 1 50, 1 7 5, 225 and 250 amperes. The non automatic N Q B -A250 carries a 250 a m pere rating and has copper conductors replacing the trip u n it. Special generator breakers have trip u n its rated at 1 00 , 1 60, and 250 amperes. I nterrupting Ratings 20,000 Amps Ac a nd 1 5,000 Amps D e ' AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a i led to: E, C/1 905/ P L Cont. Ampere Rating Technical Data 29-220 Page 23 October, 1 978 S u persedes Price List 2 9 - 220, pages 23-24, dated J u ly 1 , 1 974. .c om 8 West i n g house E l ectric Corporation Low Voltage Breaker D ivision Beaver, Pennsylvania 1 5009 . . . . . . . . . . . . . . . . 650 1 300 De 1 Generator Circuit Breaker Applications 31 3C682G28 3 1 3C682G29 31 3C682G30 None Assigned None Assigned None Assigned 4520370G02 4520370G02 4520370G02 H5925-00-789-37 1 8 H5925-00-789-371 8 H 5925-00-789-371 8 I N ote : B reakers with ratings other than than those given on this page are c on sidered as special and full description data must be pro vid ed ® Styles listed include slip -type connectors for rear connections. Order front ter m i nal connectors separately re qu ired ; see page 24. No additional charges for front connectors ordered with breakers or frames. if @ Type N Q B-A250 non-automatic. . .c om 8 Technical Data 29-220 Page 24 l A Q B - A250 a n d N Q B -A250 B reakers, Continued Net P rices See Price List 2 9 - 020 l n�tanta � eous Tnp Settmg i n Amperes® Low H ig h I Com plete Breaker® Breaker Frame Only® Style Number National Stock No. Style Number National Stock No. None None None None None 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 None None None None None 400 Cycle, Two-Pole, 500 Volts Ac 1 25 - N H 1 50 - N H 1 75 - N H 225-N H 2 50 - N H 1 91 0 91 0 91 0 91 0 910 1 560 1 560 1 560 1 560 1 560 1 31 5C574G03 31 5C574G05 31 5C574G07 3 1 5C574G09 3 1 5C574G 1 1 Assigned Assigned Assigned Assigned Assigned 1 Assigned Assigned Assigned Assigned Assigned 400 Cycle, Two-Pole, 500 Volts Ac Generator Circuit Breaker Applications 3420 3420 4200 31 5C574G 1 3 3 1 5C574 G 1 4 31 5C574G 1 5 None Assigned None Assigned None Assigned 400 Cycle, Three-Pole, 500 Volts Ac 1 25 - N H 1 50 - N H 1 75 - N H 225- N H 250- N H 1 560 1 560 1 560 1 560 1 560 91 0 91 0 910 91 0 910 I 1 31 5C574 G 1 8 31 5C574G20 31 5C574G22 31 5C574G24 31 5C574G26 None None None None None Assigned Assigned Assigned Assigned Assigned 3420 3420 4200 3 1 5C574G28 3 1 5C574G29 3 1 5C574G30 1 None Assigned None Assigned None Assigned 457D446G03 457 D446G05 457 D446G07 457D446G09 457D446 G 1 1 None None None None None 457D446G1 3 457D446G 1 4 457D446G1 5 None Assigned None Assigned None Assigned Assigned Assigned Assigned Assigned Assigned None Assigned None Assigned None Assigned 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 H5925-00-789-37 1 8 H5925 -00-789-37 1 8 H 5 925-00-789-37 1 8 H 5 925-00-789-371 8 H5925-00-789-37 1 8 457D446G1 8 457D446G20 457D446G22 457D446G24 457D446G26 None None None None None H5925-00-789-37 1 8 H5925-00-789-37 1 8 H5925-00-789-37 1 8 457D446G28 457D446G29 457D446G30 None Assigned None Assigned None Assigned 452D370G02 452D370G02 452D370G02 Assigned Assigned Assigned Assigned Assigned ar 2020 2020 2520 National Stock No. 452D370G01 452D370G01 452D370G01 400 Cycle, Three-Pole, 500 Volts Ac G enerator Circuit Breaker Applications 1 00- N G H 1 60 - N G H 250- N G H Style N u m ber an 2020 2020 2520 tM 1 00 - N G H 1 60 - N G H 250- N G H Trip U n it Only ua ls Cont. Ampere Rating Switch board M o u nt i n g Com plete breakers a n d frames include mounting hardware. Female slip con nectors are mounted in breaker base to plug onto stud projections of term inal mounting block assem blies. Order one mounting block assembly for each end of breaker. One Stud Assembly complete with 4 nuts Terminal Mtg. Block (No Studs) M o u nting Block and Stud Set (3 Studs) Style Number I National Stock No. lP I I None Assigned 1 631 443 None Assigned 3 1 3C681 G01 None Assigned 3 1 3C680G02 ( N et Weight - 2 % Lbs.) ca Description Front C o n n ected B reakers For connections made at front term i nals, pressure-type lugs required. If specified on same order, conn ectors furnished n o charge. One con nector per terminal. Select below. 25 N 1 50-N200 I � �� I - 1 75 250 I Description Solderless Connector K i t to C o nvert A Q B Frame to N O B B reaker Poles I Style Number tri ��go�Z� I Amps I National Stock No. I �g��g����� I ���= �:::��=� 20B305 5 H 1 6 None Assigned lec Cable Range Net Weight 3 .E % Lb. ® Styles listed include sli p-type connectors for rear connections. Order front terminal connectors separately if required . N o additional charges for front con nectors ordreed with breakers or frames. ® For 400 cycle breakers with higher instantaneous trip ratings. refer to Westinghouse. ww w Westi ngh ouse Electric Corporation Low Voltage B reaker Division Beaver, Pennsylvania 1 5009 ""C �"' a. .c om West i n g house Electric Corporation Low Voltage Breaker Division Beaver, Pennsylvania 1 5009 Tech n ical Data 29-220 Page 25 October, 1 97 8 S u persedes Price List 29- 220, pages 2 5 - 26, dated J u ly 1 , 1 974. Types AQB -A250, N QB -A250 250 Volts De, 500 Volts Ac 250 Amperes M aximum, 20,000 Am peres I . C. ua ls M a i led to: E, C/1 905 / P L A Q B -A250 a n d N Q B - A250 B reakers, Contin u ed lec ww w .E Tech n ical M an u a l - N AVS H I P S N o . 362-21 64: This booklet per M I L- M - 1 5 07 1 . When required, order B V R -T M -379. an Style N umber 452D377G05 I National Stock No. None Assigned None Assigned 452D377G07 90- 1 30 360-500 1 20 V De 450 V Ac U n d ervo ltage Device: Automatically trips breaker when l i n e voltage drops below 40 to 60% of norma l . After und ervoltage coil has dropped out and tripped breaker o n reduced voltage, it automatically resets by breaker action. (If und ervoltage coil is energized to 80% of norm a l ) . Select device below. Net weig ht., 1 . 1 2 l bs. Nominal Voltage 450 Ac, 60 Cycle 250 De 33 De I Voltage Range 360-500 I 1 75-355 30- 36 Pickup and Seal Volts ( M inimum) 360 1 50 22 I Dropout Voltage Style N umber National Stock N umber 290 45 25 5 452D837G01 None Assigned 452D837G02 452D837G03 None Assigned H 5 950-00-790-4869 M ax. M in. M in. M in. I n d ividual Re productions: When required, reproduction of master drawings, outline drawi ngs a n d certification sheets can be ordered as follows: Item 1 2 3 4 5 tri S pare Parts Boxes - Per M I L- B -233: After determ ining box size or n u m ber of spare trips to be stored therein (one com plete trip u nit req u i red for each 1 0 breakers or fraction thereof of a specified rating ) , contact Westi nghouse for q uotation. Voltage Range 24- 32 90-1 30 28 V De 1 1 5 V Ac ca F u n g u s - M o isture - Resistant Treat ments: (JAN -T- 1 52; J A N - C - 1 7 3 or M I L V - 1 7 3 ) : If specified, contact Westing house. External parts are coated; tri p un its are not treated. I tM A u x i l i ary Switch : I f required, style 452 D379G 02, national stock n u m ber 593000-732 -8401 . I nterna l ly mou nted switch is used to open or close control circu its as breaker operates and is provided with " "A" and " " B"' contacts. "A" contact is norma lly closed when breaker is closed a nd open when breaker is open; "B" is normally open when breaker is closed and closed with breaker open. I t has the fo l lowing rat ing at given voltages: 1 5 a m p - 1 25, 250 or 460 volts Ac; 'h amp - 1 25 volts De; X. amp- 250 volts De. N et weig ht, . 1 7 l b . Nominal Voltage ar M echan ical I nterlock : If mechanical i nterlock (switchboard use) is desired for a pair of breakers, order by descri pt ion. ( N ot sub mitted for Navy approva l . ) S h u nt Tri p : S h u nt trip attac h ments for tripping the breaker electrically from a remote point are listed i n table below. S h u nt trips have mome ntary rating only a nd for protection must be con nected i n series with a uxiliary switch. Auxiliary Switch (style 452D379G02) is included in shunt tri p n u m ber shown below. Do not order separately. Net weight, .70 lb. lP Additions H a n d l e Lock : If req u i red, order style 1 7201 0 1 . One furnished no charge per 1 0 breakers ordered, when requested. Net wt., . 1 5 1b. AB DE-ION® Circuit Breakers for Naval Shipboard Use I Description I Full size photolithic tracing of master drawing on cronoflex (mylar) Outline and drilling plan o n cronoflex (mylar) Certification data on cronoflex (mylar) Van Dyke negatives of items 1 or 2 Reproductions of items 1 , 2 or 3 D rawings Ava i l a b l e : Master draw ing 900 - J -376; front and rear connected breaker out l i n e, d r i l l i n g a n d w i ri n g d i a g ra m 452- D-834. O rdering I nformat i o n : Page 4 N et We ig ht, Lbs. AOB Complete, 3 - Pole A250 NOB Complete, 3 - Pole N 250 3 - Pole AOB, N O B Frame AOB Trip U n it, 3 - Pole 20.50 1 7.50 1 7.00 3.50 .c om Technical Data 29-220 Page 26 O u t l i n e D i m ensions AOB -A250 B reaker Front face of mounting sheet or channel Support blocks ore not supplied 2 16 � with breoke ')_ but must be ordered ---+---+--+ separately. t-�efer to drawing 313C680 Al l ports necessary to nvert o breaker ore included. 3 a·16Stud '---4-��-l----+-+ 4- 20 Mig. I Screws ua ls Line End -t---#J��i!3:�i:�H::£�:__4;co an 11 Visible amp rating interchangeable trip unit Front Sheet load End ar Front connected solderless terminals See wiring diagram and dril ling plan 4 Nuts and 1 washer supplied with tM Frame Nameplate Warning Nameplate stud Front Sheet D r i l l i ng Template ca lP Line End Handle Locking Device ( N ot Supplied With Circuit Breaker) Flat washers, lock wash ers and nuts supplied with terminal Rear connections ore on 3"centers tri mounting blocks Frant connections � centers � Dio. 3 holes for megger test lec ore on 2 Front Con nected Solderless Term inals Identification Style Number Cable Range A MCM 20B3055H 1 4 20B3055H 1 5 20B3055H16 c Min .E Max B 75 50 1 2"/,, &"h. 5"h. 1 25 100 13 61�. &'Ao 200 1 50 1 3'/,, 7'h. 6%. ww w Front Connected Terminals are not Supplied with Circuit Breaker W i r i n g Diag rams AQB NQB Line End Line End �): ) ��� m �i� Load End load End When U nder-Voltage Release is Provided When Sh11nt Trip and Auxiliary Switch is Provided A r ::,��h83 ����� y �-rfTl �-ll-fl ) ) ) og ))) : m�asr o tag ���\Shunt 1 ' L__ 1 _ : ___. 18" l n ---._ ; U n de v l e rel e e 2 " leads 18 lang L._ : • _ : _J Note: The auxiliary switch must be used with each shunt trip. Connect one side of shunt trip i n series with "A " contact ( Closed when breaker is closed) of auxiliary switch when connecting to power supply. trip 2 leads 18" long Technical Data 29-220 Types AQB -A250, N Q B -A250 250 Volts De, 500 Volts Ac 250 Amperes Maximum, 20,000 Am peres I . C. AB DE-ION® Circuit Breakers for Naval Shipboard Use 4 3 I 1\ 10 8 6 40 Maximum 10 8 \ 4 3 I Tnpping Time I fo 2 M , n . 5 to 1 5 M ; n . = � 0 0 - 0 0 0 0 00 0 0 0 0 0 0 0 111 0 0 0 00 0 0 o o o o 0 0 0 0 0 00 0 0 0 0 0 lec I .B .6 .5 - N t<"l -t" •nw oo o - Percent Rated Current ..n o - (\J o o r<"l v o <.!) 0 Q �- �:f �;f .E O perat i n g C h a racteristics Trip U n it Rati n g 1 25 - 25 0 Amperes 5o·c Ambient - Cold Start, 60 Cycle, Ac or De ww w Specification M I L- C - 1 7361 This specification covers all thermal - mag netic AQB breakers. It requi res that they carry 1 50% of current ratings for at least one hour a nd that thermal elements i n itiate tri pping at 225% rated cu rrent within one hour and at 600% i n 2 5 seconds plus or minus 25%. The instantaneous mag netic settings for each conti n uous ratings are based o n i ntended appli cations. (Thermal tripping tests are conducted with all poles in series i n 5o·c ambient; each pole is tested i ndivid ually to check magnetic settings.) • • 4 5 3 2 90 5 3 1\ - N 0 0 "' 0 0 <t 0 0 0 g �� 0 0 � g g 0 N "' / I eo 2 - 0 N T r i p U n it Rati n g 7 0 0 0 C ill O 0 0 !2 0 ,. Ij O perati n g C h a racteristics Trip U n it Rating 1 25-250 Amperes 5o·c Ambient - Cold Start 400 Cycle Ac I0 I B .6 5 ' ·" Per Cent Rated Current \\ tri � u I 40 0 20 5 10 I ca 7 5 4 3 2 0 0 10 ' \ 1\ 10 _ 2 0 M 1 n o r More 40 20 1\ I 4o o 20 = I 40 4 3 2 Maximum M i n imum 20 � 300 200 150 lP \ 10 8 6 Percent of Tr i p Element RaTings 4 3 M i n i mum 20 � 20 I 40 u I 0 I I I I I I I I II II I 30 1\ 2 � � an 1\ 10 8 6 0 J: ar 20 lime 25 Seconds± 2 5 % Less Th a n 1 Hour More Than I Hour 600 225 1 50 30 I I I I Tripping tM I II I I I I I 50 400 Cycle B reakers A O B -A250 G e n erator B reaker Percent of Tr i p E l e m e n t Rating Page 27 ua ls M a i led to: E, C/1 905/PL C h a racteristic C u rves A Q B - A250 .c om October, 1 978 S u persedes Price List 29- 220, pages 2 7 - 28, dated February 1 7, 1 969. Westi n g house Electric Corporati o n Low Voltage B reaker Division Beaver, Pennsylvania 1 5009 70 o o oooo o o o o o O O OO O O Q O O O O t<"l '<f i{)\Ll <D Q IO O O O O Percent Rated Curren1 - - N � '¢ W - II 60 o oo o 0 00 0 0 0 0 0 0- 1{)- 6 c;i 50 40 - N r0 30 O perat i n g C h a racteristics Trip U n its, Types 1 00 N G H , 1 60 N G H , 250NG H , 1 00 N G , 1 60 N G a nd 250NG for use with generator circuit breakers 5 0 ° C ambient - Cold Start A c o r D e c .. :.0 E <( 10 0 o 0.5 Foetor 1.0 1.5 2.0 2.5 3,0 3.5 4.0 4.5 To determ ine the trip u n it rating to be used, when the load c u rrent and ambient are known, m u ltiply the load current by the factor obtained from this curve for the known ambient. The result will be the ideal trip u n it rating. H owever, since trip u n its are furnished only with sta ndard ratings as per Navy spec., select the sta ndard trip unit whose rating is equal to or one rating higher than the ideal rati n g . .c om Technical Data 29-220 .E lec tri ca lP ar tM an ua ls Page 28 ww w West ing house Electric Corporation Low Voltage Breaker Division Beaver, Pennsylvania 1 50 0 9 .c om Tech nical Data Westinghouse Electric Corporation Distribution a n d Control Busines s U n it E lectrical Components Division Pitts b u rg h , Pennsylva n i a , U . S .A. 1 5220 J u ly 1 99 1 S upe rsedes Tech n ical Data 29-220, pages 29-30, dated A p r i l 1 99 1 M a i led to : E, D, C/29-200A an These breakers are availa ble with i nter changeable trip u n its in ratings of 1 25, 1 50, 1 7 5, 225 and 250 amperes. The n o n a utomatic N QB -A250 carries a 250 ampere rating and has copper conductors re placing the trip u n it. Special generator breakers have trip u n its rated at 1 00, 1 60, and 250 am peres. I nterrupting Ratings 20,000 Amps Ac and 1 5,000 Amps De AQB - A250 circuit breakers are used pri marily to protect feeder circuits, however, those fo llowed by ' " N M" in the price table have higher magnetic setti ngs to al low tor motor starting. Breakers with settings spe cifically for use with generators are desi g nated '" N G " i n t h e price table. ar tM AQ B - A250 breakers can be ordered with undervoltage release devices, auxil iary switches and shunt trip attac hments com plete with auxili ary switch. These attach ments are also easily installed in the field. Low High De Low High I Complete Breaker<D Style N umber De Two-Pole 500 Volts Ae, 250 Volts 650 1 950 650 1 950 650 1 950 225-N 225-NM 250-N 250-N M 250® 650 1 300 1 500 3000 650 1 300 1 700 3400 Non-Auto 1 1 300 3900 1 300 3900 1 300 3900 1 650 2250 650 2250 650 2250 1 300 41 00 1 300 4 1 00 1 300 4 1 00 650 1 300 1 770 3550 650 1 300 1 850 3800 N on-Auto 1 31 3C682G03 31 3C682G04 31 3C682G05 31 3C682G06 31 3C682G07 31 3C682G08 De . . . . . . . . . . . . . . . . 650 1 300 650 1 950 650 1 950 650 1 950 31 3C682 G 1 3 31 3C682 G 1 4 31 3C682 G 1 5 1 650 1300 1 500 3000 650 1 300 1 700 3400 Non-Auto w 225-N 225-N M 250-N 250-NM 250® 1 1 75 2350 1 950 3900 . . . . ww 1 00-NG 1 60 - N G 2 50 - N G 1 . . • . 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 452D37 1 G03 4520371 G04 452D371 G 0 5 4520371 G 0 6 452D371 G07 452D371 G08 452D370G01 452D370G01 452D370G01 452D370G01 452D370G03 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 452D371 G09 452D371 G 1 0 4520371 G 1 1 4520371 G 1 2 29B27 1 0G05 De . .. .. .. .. .. 452D370G01 452D370G01 452D370G01 5925-00-796-4371 5925-00-796-4371 5925-00-796-4371 452D371 G 1 3 452D37 1 G 1 4 452D371 G 1 5 5925-00-789-37 1 8 5925-00-789-37 18 5925-00-789-37 18 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 4520371 G 1 8 4520371 G 1 9 4520371 G20 452D371 G 2 1 452D37 1 G 2 2 452D371 G23 5925-00-795-4958 5925-00-839-0289 5925-00-795-4957 5925-00-839-0290 5925-00-796-4439 5925-00-789-371 8 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 592 5-00-831 -8801 452D37 1 G24 452D371 G 2 5 452D37 1 G26 452D371 G27 29B2710G06 5925-00-839-0291 5925-00-839-0292 5925-00-839-0293 5925-00-690-7568 5925-00-831 -8800 4520371 G28 4520371 G29 4520371 G30 5925-00-852-7809 5925-00-795-4956 .............. 5925-00-248-1 425 5925-01 -031 -9909 5925-01 -229-4448 5925-01 -235-071 0 5925-0 1 - 1 92-3985 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 650 1 300 1 770 3550 650 1 300 1 850 3800 Non-Auto 31 3C682G24 31 3C682G25 31 3C682G26 31 3C682G27 31 3C682G36 5925-01-1 73-2587 5925-01-21 0-5267 . .. ... . .... 5925-01 -272-3805 .. ...... . . . 452D370G02 452D370G02 452D370G02 452D370G02 452D370G04 . . . . . . . . . . . . . . . 6 5 0 1 300 � National Stock No. National Stock N o. 31 3C682 G 1 8 31 3C682G 1 9 31 3C682G20 31 3C682G21 31 3C682G22 31 3C682G23 Three-Pole 500 Volts Ac, 250 Volts T r i p Unit Only Style N u m ber 1 30 0 4 1 00 1 300 41 00 1 300 4 1 00 650 2250 650 2250 650 2250 .E 1 300 3900 1 300 3900 1 300 3900 1 \ Breaker Frame Only<D Style N umber 5925-00-793-6865 5925-00-1 75-5058 5925-00-064-7834 G enerator Circuit Breaker Applications lec 1 1 75 2350 1 950 3900 . . . . . . . . Three-Pole 500 Volts Ae, 250 Volts 1 25 - N 1 25 - N M 1 50 - N 1 50 - N M 1 75 - N 1 75 - N M 5925-01 -233-6525 31 3C682G09 31 3C682 G 1 0 31 3C682G 1 1 3 1 3C682G 1 2 31 3C682G31 Two Pole 500 Volts Ae, 250 Volts 1 00 - N G 1 60 - N G 2 50 - N G Stock No. tri 1 25 - N 1 25 - N M 1 50 - N 1 50- N M 1 75 - N 1 75 - N M I National ca I Ins!. Trip Setting - Amps lP List Prices See Price List 29-020 Ac AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls S pecificat i o n : M I L- C - 1 7361 1 25-250 A m peres 500 Volts Ac and 250 Volts De Two a n d T h ree- Pole ' Page 29 Types AQB -A250, N QB -A250 250 Volts De, 500 Volts Ac 250 Amperes M aximum, 20,000 Am peres I. C. A Q B -A250 a n d N O B -A250 B reakers Cont. Ampere Rating 29-220 De . . . .. . 1 Generator Circuit B reaker Applications 31 3C682G28 31 3C682G29 31 3C682G30 5925-01 -080-2226 5925-0 1 - 1 04-4625 .. . .. .. .. .. .. . 452D370G02 452D370G02 452D370G02 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 1 N ot e : Breakers with ratings other than than those given on this page are considered as special and full description data must be provi d ed G) Styles listed include slip-type connectors for rear connections. Order front terminal connectors sepa rately if required; see page 30. No additional charges for front connectors ordered with breakers o r frames. ® Type NQB-A250 non-automatic. . .c om Tec h n i ca l Data 29-220 Page 30 AQB-A250 and NOB-A250 Breakers, Conti n u ed List Prices See Price List 29-020 Instantaneou s Tnp Settmg in AmperesCD Low High I Breaker Frame Only® Complete Breaker® National Stock No. Style N umber Style N umber National Stock No. 452D370G01 452D370G01 452D370G01 452D370G01 452D370G01 5925-00-796-437 1 5925-00-796-437 1 5925-00-796-437 1 5925-00-796-437 1 5925-00-796-437 1 400 Cycle, Two-Pole, 500 Volts Ac 1 25 - N H 1 50 - N H 1 75 - N H 225 - N H 250- N H 1 91 0 910 91 0 91 0 91 0 1 1 1 1 1 560 560 560 560 560 1 31 5C574G03 31 5C574G05 31 5C574G07 31 5C574G09 31 5C574G 1 1 1 400 Cycle, Two-Pole, 500 Volts Ac Generator Circuit Breaker Applications 3420 3420 4200 31 5C574 G 1 3 3 1 5 C574 G 1 4 31 5C574G 1 5 ........ .. .... . . . . . . . . .. . . . . . ....... .. .. .. 400 Cycle, Three-Pole, 500 Volts Ac 91 0 91 0 91 0 91 0 91 0 1 25 - N H 1 50 - N H 1 75 - N H 225- N H 2 50 - N H I 1 560 1 560 1 560 1 560 1 560 1 31 5C574 G 1 8 31 5C574G20 31 5C574G22 31 5C574G24 31 5C574G26 5925-01-075-8931 5925-01 - 1 00-4027 5925-01 - 1 93-6055 1 452D370G01 452D370G01 452D370G01 5925·00-796-437 1 5925-00-796-437 1 5925-00-796-437 1 452D370G02 452D370G02 452D370G02 452D370G02 452D370G02 400 Cycle, Three-Pole, 500 Volts Ac G enerator Circuit Breaker Applications 2020 2020 2520 3420 3420 4200 31 5C574G28 31 5C574G29 31 5C574G30 .... .. .. .. .. .. ...... .... .... .... .. .. .. .. .. 452D370G02 452D370G02 452D370G02 National Stock N o . 457D446G03 457D446G05 457D446G07 457D446G09 457 D446G 1 1 ........... . . . · · · · · · · · · · · · · · .............. .............. ......... ..... · · · · · · · · · · · · · · 457D446G 1 3 457D446 G 1 4 457D446 G 1 5 5925-00-758-6227 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 5925·00-789-37 1 8 5925-00-789-37 1 8 457D446 G 1 8 457D446G20 457D446G22 457D446G24 457D446G26 5925-00-803-5491 5925-00-803-5488 5925-00-899-9904 5925-0 1 - 1 93-6056 5925-0 1 - 1 49-4269 5925-00-789-37 1 8 5925-00-789-37 1 8 5925-00-789-37 1 8 457D446G28 457D446G29 457D446G30 5925-00-238-51 98 5925-00-803-5489 ..... ......... · · · · · · · · · · · · · · ar 1 00 - N G H 1 60- N G H 2 50 - N G H Style N umber an 2020 2020 2520 tM 1 00 - N G H 1 60 - N G H 2 50 - N G H Trip Unit Only ua ls I Cont. Ampere Rating Switch board M o u nting Complete breakers a n d frames incl ude mounting hardware. Female s l i p connectors are mou nted in breaker base to plug onto stud projections of terminal mounting block assem blies. Order one mounting block assembly for each end of breaker. I One Stud Assembly complete with 4 n uts Terminal Mtg. Block ( N o Studs) Mounting Block and Stud Set (3 Studs) Style N u mber National Stock No. lP Description I ca 1 631 443 31 3C68 1 G01 31 3C680G02 ( N et Weight - 2 10 Lbs.) Front C o n n ected B reakers For connections made at front termin als, pressure-type lugs req u i red. If specified o n same order, connectors furnished n o charge. One con nector per terminal . Select below. N40- N 7 5 N 1 00- N 1 25 N 1 50-N200 Amps 1 25 1 50 - 1 7 5 250 I I I Description Solderless Connector K it to Co nvert A O B Frame to N O B B reaker Poles National Stock No. 3 I' I Style N umber tri I 20B305 5 H 1 4 20B305 5 H 1 5 20B305 5 H 1 6 lec 1 Cable Range I I · ............ National Stock No. . .............. .............. Net Weight .E 10 Lb. CD For 400 cycle breakers with higher i n stantaneous trip ratings, refer to Westi nghouse. ® Styles listed include slip-type connectors for rear connections. Order front terminal connectors separately if required. No additional charges for front connectors ordered with breakers o r frames. ww w Westi n g h ouse E l ectric Corporation Distribution and Control B u s i n es s U n i t Electrical Components Division Pittsburg h , Pennsylvania, U . S .A. 1 5220 July 1 99 1 .c om Tec h n ical Data 29-220 Westinghouse Electric Corporation Distri bution a n d Control B u s i n ess Unit E l ectrical Components Division Pittsb u r g h , Pen nsylva n i a , U . S.A. 1 5220 AOB -A250 a n d N O B -A250 B reakers, Conti n ued Contact Westingho use for o t h e r rati n g s o r types of m o u nting. .E lec Technical Manual - NAVSHIPS No. 3622164: This booklet per M I L-M- 1 507 1 . W h e n req u i red, o rder BVR-TM-379A. w Voltage Range 1 I Style N u mber 452D377G05 tM 24- 32 90- 1 30 an 28 V De 1 1 5 V Ac 1 20 V De 450 V Ac 90- 1 30 360- 500 I 452D377G07 I National Stock No. 5925-00-83 1 -8808 5925-01 -007-5836 U n d ervoltage Device: Automatically trips breaker when line voltage drops below 40 to 60% of normal. After u n dervoltage coil has dropped out and tripped breaker o n red uced voltage, it automatically resets by breaker action. ( If undervoltage coil is energ ized to 80% of norma l ) . Select device below. Net weight., 1 . 1 2 lbs. Nominal Voltage 450 Ac, 60 Cycle 250 De 33 De I Voltage Range 360-500 I Pickup and Seal Volts (Mi nimum) 360 1 75-355 30- 36 1 50 22 I Dropcut Voltage 290 45 25 5 Max. Min. Min. M in. I Style N umber National Stock N u mber 452D837G01 5925-00-920-3099 452D837G02 452D837G03 5950-00-790-4869 I n d i v i d u a l R e productions: When required, reproduction of master drawings, outline drawings and certification sheets can be ordered as follows: Item 1 2 3 4 tri - M o isture - Resistant Treat (JAN -T- 1 52; J A N - C- 1 7 3 or M I L If specified, contact Westing house. parts are coated; trip u n its are not ww I ca Auxiliary Switch : The most commonly used, when requi red, is style 452D379G02, national stock n u m be r 5930-00-732-840 1 . I ntern a l ly mou nted switch is used to open or close control circuits a s breaker operates and is provided with "A" and "B" contacts. "A" contact i s norma l l y closed when breaker is closed and open when breaker i s o pe n ; " B " i s normally open when breaker is closed and closed with breaker open. It has the following rati n g at given volta ges: 15 a m p - 1 25, 250 o r 460 volts Ac; '12 a m p- 1 25 volts De; % a m p-250 volts De. Net weight, . 1 7 l b . Nominal Voltage ar M echan ical I nterl ock : I f mechanical interlock (switchboard use) is desired for a pair of brea kers, order by description. ( N ot submitted for Navy approval.) Shunt Tri p : S h u nt trip attachme nts fo r tripping the breaker electrically from a remote point are l isted in ta ble below. S h u nt trips have momentary rati n g only and for protection m u st be conn ected i n series with a u x i l i a ry switch. An Auxiliary Switch is i ncluded in the s h u nt trip n u m b e rs shown below. Do not order sepa rate ly. Net wei g ht, .70 l b . lP Additions H a n d l e Lock : If required, order style 1 7 201 0 1 . One furnished no charge per 1 0 breakers ordered, when requested. N et wt., . 1 5 1b. AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Types A O B - A250, N O B -A250 250 Volts De, 500 Volts Ac 250 Amperes Maximum, 20,000 Amperes I . C . J u ly 1 99 1 Supersedes Tech nical Data 29-220, pages 31 -32, dated April 1 991 M a i led to : E , D, C/29-200A Fungus m ents: V- 1 73 ) : External treated. Page 3 1 I I Description I Full size photolithic tracing of master drawing on vellum Outline and drilling plan on v e l l u m Certification data on v e l l u m Reproductions of items 1 , 2, or 3 D ra w i n g s Ava i l a b l e : Master drawing 900 - J -376; front and rear connected breaker out l i ne, dri l l i n g and wiring diagram 452 - D -834. Orde r i n g I n fo rmation: Page 4 N et We ig ht, Lbs. AOB Complete, 3- Pole A250 NOB Complete, 3 - Pole N 250 3 - Pole AOB, NOB Frame AOB Trip U nit, 3 - Pole 20.50 1 7.50 1 7 .00 3.50 .c om Tec h n i ca l Data 29-220 Page 32 O u t l i n e D i m e n s i o n s A O B -A250 B reaker ua ls line End I Mtg. Screws H a ndle locki n g Device '--1--�----r---IH- 4-20 Load End Front Sheet ar Visible amp rating interchangeable trip unit See wiring diagram and dril ling plan 4 Nuts and 1 washer supplied with stud tM Frame Nameplate an 11 Warning Nameplate ) Circuit Br ( N ot Su pplied With ea k e r D r i l l i ng Plan B locks Front Sheet D r i l l i n g Template mounting blocks 3� �1 5 Front co�necti ons are on 24 centers j C Rearconnections il !2 are on 3"centers � lec 1 Front Connected Solderless Ter m i n a l s Identification Style Number Cable Range A B MCM Min 76 50 20B3055H1 5 1 25 20B3055H 1 6 200 .E Max 20B3055H 1 4 c 1 2'Y,, 6"ho 521h, 100 13 61Y,. &Y,, 1 50 1 3'Ao 7%. 8%. w Front Connected Terminals are not Supplied with Circuit Breaker ww 1i oia. 3hales tri Flat washers, lock washers and nuts supplied with terminal ca lP For Terminal M o u nting far megger test Wiring D iagrams AQB NOB line End line E n d JU }H load End load End �)) When Sh•mt Trip and Auxiliary Switch is Provided When U nder-Voltage Release is Provided r - - - - - - - -, I : r r - -- - - - -, a_nd B uxiliar i l l f. I, : Asw1tch 3Aleads y 1 y I. l,l : 1 18" long ---._ l ) ) ) : I 1 I 1 n er a ta : m� ase _ Shunt' �wffll leads a • [__ _ : ...J U d re l e v l 2 ge 18" l ng L__ • : _J Note: The auxiliary switch must be used with each shunt trip. Connect one side of shunt trip in series with "A" contact (Closed when breaker is closed) of auxiliary switch when connecting to power supply. trip 2 leads 18" long Westi n g house E l ectric Corporati o n Distri bution a n d Control Busi ness U n it Electrical Co m po n ents Division Pittsburgh, Pen nsylva nia, U . S .A. 1 5220 J u ly 1 991 Type A Q B - L F 1 00, 1 00 Am peres M aximum, Type A Q B - LF250, 250 Amperes Maximum, 500 Volts Ac, 1 00,000 Amperes I . C. ar lP ca tri A O B - L F1 00 fused Navy circuit breaker N ote: A Q B - LF1 00 breakers are sold for replacement o n ly . They a re n o longer o n Navy Q u a l ified P rod uct list. Descri pt i o n These breakers a r e essentially standard Navy circuit breakers incorporating c u rrent l i mit ing fuses i n one compact device. The fuses are mou nted i n a removable molded hous i n g which plugs into and becomes an integral part of the breaker. Fuses are easily replaced from the front sim ply by loosening four screws and pulling out the fuse housi ng. an Like standard Navy brea kers, they are de signed for use i n switchboards, load centers a nd panel boards. AQ B - L F circuit breakers are available in three-pole desig n and for rear connection only. tM A Q B - LF1 00 a n d A Q B - LF250 B reakers A p p l ication AQB - LF1 00 a nd AQB- LF250 circuit break ers are for use in low voltage distribution systems where available fault current ex ceed the interrupting rati ngs of standard molded case breakers but does not exceed 1 00,000 a m peres. AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Mai led to: E, C/1 905/ P L A Q B - LF250 fused N avy circuit breaker lec F u s e T r i p Lever Instantaneous T r i p Adjusting Wheels S l id e Type Connectors for F u s e Contacts An interlock prevents the breaker being closed if a ny of the three fuses are blown and the fuse housing is so designed that all three fuses m ust be u n blown before the housing can be mounted in its correct position on the breaker. Removal of the fuse housing automati cally opens breaker and provides visual assurance that the circuit is disconn ected. O peration The thermal mag netic trip u n it of the sta nd ard breaker provides protection o n overloads and short circuits below a predetermined value without affecting the fuses. H owever, these specially coordinated fuses assume the fault cleari ng duty on high m a g n itude short circu its a nd extend the interrupting capacity to 1 00,000 a mperes. The common trip feature of the circuit breaker is retained so that a l l poles o p e n when a ny fuse blows. Fast a cti n g current l imiting fuses clear s hort circuits i n less than one- half cycle. Conseque ntly, peak let through cu rrents are greatly reduced a nd bus-su pporti n g members or current carrying parts do not have to be desig ned to meet maxi m u m peak current. .E w Technical Data 29-220 Page 33 October, 1 978 Su persedes Price List 29- 220, pages 33- 34, dated J u ly 1 , 1 974. ww .c om 8 West i n g house E l ectric Corporation Low Voltage Breaker Division Beaver, Pennsylvania 1 5009 Fuse Plug- I n Contacts Fuse Housing U ni t R e m oved Current L i m it i n g Fuses Page 34 A Q B - L F1 00 Fused B reaker Specification : M I L- C - 1 7361 1 5 - 1 00 Am ps, 500 Volts Ac, 60 Cycles, T h ree- Pole, I nterru pting R ati n g : 1 00,000 Amperes AQB - LF1 00 breakers are designed for the same appl ication as the AQB -A1 00 ( non -fused) circuit breaker except that they may be applied on circuits where fault cu rrents up to 1 00,000 amps are avai lable. B reakers designated by the suffix " D F" in the table have setti ngs designed for the protection of feeder c i rcuits and those followed by "D" have hig her mag netic settings to a l low for motor starting. Net Prices See Price List 29- 020 lnstantaneous Trip Setting i n Amps Low Breaker Complete ------ Style N umber@ Breaker Frame® Trip U nit Style N umber Style N u mber National Stock N o . Fuses National Stock N o . an Cont. Amp. Rating ua ls Note: A Q B - LF1 00 breakers a re sold for replacement o n ly. They a re n o l o n g e r o n Navy Q u a l if i ed P rod uct l ist. High Three-Pole 500 Volts A c .c om Technical Data 29-220 Style N u mber@ Quant. Req. 90 1 80 1 05 21 0 452D391 G 1 6 452D391 G 1 7 452D390G02 H5925-00- 6 1 7 - 83 1 2 452D390G02 H5925-00- 6 1 7-831 2 452D385G 1 3 452D384G 1 3 H5925-00-849-8481 H5925-00-6 5 5 - 1 1 56 31 3C743H02 31 3C743H02 3 3 25 - D F 25-D 1 80 300 21 0 350 452D391 G 1 8 452D391 G 1 9 452D390G02 452D390G02 H 5 925-00-61 7-831 2 H5925-00 -61 7-831 2 452D385G 1 5 452D384G 1 5 H5925-00-65 5 - 1 1 57 H5925-00-65 5 - 1 1 58 31 3C743H02 31 3C743H02 3 3 50-DF 50-D 300 600 350 700 452D391 G20 452D391 G 2 1 452 D390G02 4 5 2D390G02 H5925-00-61 7 -831 2 H5925-00-6 1 7 -831 2 452D385 G 1 7 452D384 G 1 7 H5925 -00-6 5 5- 1 1 59 H5925-00-65 5 - 1 1 60 3 1 3C743H03 3 1 3C743H03 3 3 75-DF 75-D 450 525 900 1 050 452D391 G 2 2 452D391 G23 452D390G02 452D390G02 H5925-00- 6 1 7 - 831 2 H5925-00 -6 1 7 -831 2 452D385G20 452D384G20 H5925 -00-65 5- 1 1 61 H5925-00-65 5 - 1 1 62 31 3C743H03 31 3C743H03 3 3 1 00 - D F 1 00 - D 600 700 1 200 1 400 452D391 G24 452D391 G25 452D390G02 452D390G02 H 5 925-00-61 7-831 2 H5925-00-61 7 - 83 1 2 452D385G23 452 D384G23 H5925-00-655- 1 1 63 H5925-00-655- 1 1 64 3 1 3C743H03 3 1 3C743H03 3 3 ar tM 1 5- D F 1 5-D lP ® Breaker frame consists of frame with its fuse housing u n it and slip type connectors for back connection. but does not incl ude trip unit. fuses or mounting blocks. Order these separately, trip u nits and fuses from table above and mounting blocks from listings below. @ National stock number not assigned. ca Switc h board M o u n t i n g B reaker frame incl udes mounting hardware. Fema l e slip connectors are mou nted on the rear for plugging onto stud projections of te rminal mounting block assemblies. Order one for each end of the breaker. Description Style N u mber National Stock No. One Stud Assembly Complete with 4 Nuts Terminal Mounting Block (No Studs) Mounting Block and Stud Set (3 Studs) 1 631 442 1 764 240 301 P272G01 H 5 940-00-501 -91 20 None Assigned None Assigned tri Add itions I n dividual Reproductio ns: When required, reproductions of master drawings, outline drawings and certification sheets can be ordered as follows: Description 1 2 Full Size Photolithic Tracing of M aster Drawing on Cronoflex (Mylar) Outline and Drilling Plan on Cronoflex (Mylar) Certification Data o n Cronoflex (Mylar) Van Dyke Negatives on Items 1 or 2 Reproduction of Items 1 . 2 or 3 3 4 5 lec Item .E D rawi n g s Ava i l a b l e : Master drawing 900J 377; outl i n e drilling plan and wiring diagram: 451 D71 1 . H an d l e Lock ( Fo r S h i pboard M a i ntenance Use O n l y ) : Order style n u m ber 1 6 1 4 485. F u n g us- M o isture- Resistant Treatments ( J A N -T-1 52; J A N - C - 1 73 o r M I L- V - 1 73 ) : I f specified, contact Westi ng house. External parts are coated; trip u n its are not treated. ww w Tec h n ical M a n u a l : NAVS H I PS n u mber 362 - 2 1 66. This booklet per M I L- M - 1 507 1 . When required, order B V R -T M -380. R e p a i r P a rts: Requ irements per vessel i n clude ( 1 ) o n e com plete trip u nit fo r each 1 0 breakers or fraction thereof of a specified rati n g (2) one fuse for each 20 fuses with a m i n i m u m qua ntity of nine fuses of a speci fied rating (3) one fuse housing u n it for each 20 breakers or fraction thereof. Fuse H o using U n it ( N o F u ses) Style N umber National Stock No. 31 3C742G01 H6605-00-799-3521 S pare Parts Boxes - Per M I L- B -233: After determ ining box size or n u mber of spare trips to be stored therein. contact Westi n g house. Net We ig ht - Lbs. AQB B reaker Complete 3 - Pole AQB B reaker Frame Only Com plete with Fuse U n it Assembly Without Fuses Trip U n it 3 - Pole Fuse U n it Assem bly Without Fuses One M o u nting B l ock with 3 Studs Current Limiting Fuse Circuit Breaker H a ndle Locking Device 1 3.62 9.68 2.62 1 .6 2 1 .6 2 .45 .25 Technical Data 29-220 Page 3 5 October, 1 978 Supersedes Price List 29- 220, pages 3 5-36, dated J u ly 1 , 1 974. Type AQ B - LF1 00, 1 00 Amperes Maximum Type A O B - LF250, 250 Amperes Maximum 500 Volts Ac, 1 00,000 Am peres I. C. A Q B - L F250 Fused B reaker Specificati o n : Ml L - C - 1 7361 o n circu its with available fault currents up to 1 00,000 amps. Only three-pole breakers are available. These fused breakers are designed for appl i cations similar t o those for A O B - A250 ( n o n -fused ) . H owever, because of their cu rrent limiting fuses, they can be applied U ndervoltage release devices, shunt trips and/or auxil iary switches are available for the AOB - LF250 and can be easily installed i n the field. Breaker C o m p l ete Breaker Frame@ Style N umber Style N u mber National Stock N o . High tM N et Prices See Price List 29- 020 Low Those breakers identified by the suffix " L M " i n the price table have hig her magnetic set tings for motor starting while those carrying the suffix L are set for the protection of feeder circuits. Test report number 541 9-27. an 1 25-250 A m ps o 500 Volts Ac, 60 Cycles o T h ree- Po l e I nterrupting Rati n g : 1 00,000 Amperes l nstantaneous Trip Setting i n Amps AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a iled to: E, C/1 905/ P L Cont. Amp. Rating .c om 8 West i n g house Electric Corporation Low Voltage Breaker Division Beaver, Pennsylvania 1 5009 " " Trip U n it Style N u mber Fuses Nati onal Stock No. Style N u mberaJ Quant. Req. ar Three-Pole 500 Volts Ac ( Refer to Westing house for Two-Pole Styles a n d Prices) 6 5 0 1 300 1 500 3000 31 3C748G 1 8 31 3C748G 1 9 452D820G02 452D820G02 H 5 925-00- 6 1 7 - 83 1 3 H5925-00-61 7 -831 3 452D821 G 1 8 452D821 G 1 9 H5925-00-65 5 - 1 1 65 H5925-00-65 5 - 1 1 66 3 1 3C743H01 3 1 3C743H01 3 3 1 50 - L 1 50 - LM 6 5 0 1 300 1 500 3000 31 3C748G20 31 3C748G21 452 D820G02 452D820G02 H5925-00-61 7 -831 3 H 5 925-00-61 7 - 831 3 452D821 G20 452D821 G 2 1 H 5 925-00-65 5 - 1 1 67 H 5925-00-65 5 - 1 1 68 3 1 3C743H01 3 1 3C743H01 3 3 1 75 - L 1 75 - LM 650 1 300 1 500 3000 3 1 3C748G22 3 1 3C748G23 452D820G02 452D820G02 H 5 925-00-61 7 -831 3 H 5 925-00-61 7 -831 3 452D821 G22 452D821 G23 H 5 925-00-65 5 - 1 1 69 H 5 925-00-65 5- 1 1 70 3 1 3C743H01 3 1 3C743H01 3 3 225-L 225- LM 6 5 0 1 300 1 500 3000 3 1 3C748G24 3 1 3C748G25 452D820G02 4 5 2D820G02 H5925-00-61 7 -831 3 H5925-00 - 6 1 7 -831 3 452D821 G24 452D821 G 2 5 H 5 925-00-65 5 - 1 1 71 H 5925-00-655- 1 1 72 31 3C743H01 31 3C743H01 3 3 250-L 250-LM 650 1 300 1 500 3000 31 3C748G26 31 3C748G27 Net Wt. 32.00 Lbs. ca lP 1 25 - L 1 25 - LM 452D820G02 H5925-00-61 7 -831 3 452D820G02 H5925-00 - 6 1 7 - 831 3 Net Wt. 24.50 Lbs. 452D821 G26 H5925-00-65 5 - 1 1 74 452D821 G27 H5925-00-65 5 - 1 1 73 Net Wt. 3.00 Lbs. 31 3C743H01 3 31 3C743H01 3 Net Wt. 1 .50 Lbs. @ B reaker frame consists of frame with its fuse housing unit and slip type connector for back connection. but does not include trip unit. fuses or mounting blocks Order these separately. trip units from table above and mounting blocks from listings below. tri ® National stock number H5925-00-624-3049. lec Switch board M o u nt i n g Breaker frame incl udes mounting hardware. Female slip connectors are mounted on the rear for plugging onto stud projections of terminal mounting block assemblies. Order one for each end of breaker. Description One Stud Assembly Complete with 4 Nuts Terminal Mounting Block ( N o Studs) Mounting Block and Stud Set (3 Studs) ® Style Number National Stock No. 1 631 443 3 1 3C681 G 0 1 31 3 C680G02 H 5 940-00-501 - 9 1 1 9 None Assigned None Assigned .E ® Net Weight 3.00 Lbs. A d d itions I n d iv i d u a l R e p roductions: When required, reprod uctions of master drawings, outline drawings, and certifi cation sheets can be ordered at the following prices: Description 1 2 3 4 5 Full size photolithic tracing of master drawing on cronoflex (mylar) Outline and drilling plan on cronoflex (mylar) Certification data on cronoflex (mylar) Van Dyke negatives on items 1 o r 2 Reproduction of items 1 , 2 or 3 w Item ww D ra w i n g s Ava i l a b l e : M aster drawing 900 - J - 379; breaker outline, dri l l i ng and wiring diagram 451 D 2 50. H a n d l e Lock ( Fo r s h i pboard m a i ntenance use o n l y ) : Order style number 1 72 0 1 01 . Net weight . 1 0 lbs. Auxi l i a ry Switch: For description see AQB -A250 breaker, page 25. Style n umber 4 5 2 D 379G02 same as for AOB -A250. Net weight . 1 7 lbs. S h u nt Trip Attachment: To order refer to AOB -A250 breaker on page 25. Style n u mbers and net prices are same as those for AQB - A250. Net weight .70 lbs. U nd e rvoltage Device: To order, refer to AOB -A250 breaker on page 2 5 . Style numbers and net prices are same as those for AOB -A250. Net weight 1 .1 2 lbs. Tech nical M a n u a l : N AVS H I PS number 362 - 2 1 65. This booklet per M I L- M - 1 5 07 1 . When req u i red, order BVR- TM-38 1 . R e p a i r Parts: Requirements per vessel i n c l ude: ( 1 ) o n e complete trip u n i t f o r each 1 0 breakers or fraction thereof of a specified ratin g . (2) one fuse for each 2 0 fuses ordered with a m i n i m u m of nine. (3) one fuse housing u n it for each 2 0 breakers or fraction thereof. Fuse H o u s i n g U n it ( N o F u ses) Style N umber Stock No. Net Weight 452D832G01 None Assigned 4.50 Lbs. National Spare Parts Boxes: Per M I L- B -233. After determin ing box size o r nu mber of s pare trips to be stored therein, contact Westing house. O rdering I n formation: See page 4. N et Weig hts : See listings i n tables and additions. .c om 8 Technical Data 29-220 Page 36 O u t l i n e D i mensions AQB- LF1 00 B reakers Jl 16 5 8 tg Line End M . b o l t s supplied w i t h bre a k e r, e xt e n d b e low bot tom 5 of 64 � br e a k er Baits Support blocks ore not supplied with breaker, but must be ordered separately, refer to dwg. I A4457 all ports necessary Ia convert a breaker are i ncluded 1 ua ls J - 20 4 an S l i p Contact Assembly Flat washers, lock washers and nuts supplied with terminal mig. block tM 0 Mig � - 2screws (c a p ! i ve l Visible amp rating i n t e rcha n g e a bl e trip unit Front Cover Cutout lP ar Drilling Plan For Mo unting Panel ( R ear Connected) R Mm. . / ca 9 i6- 7 o· ;e; - 10. 4 ho l e s � f r om c e n t e r p o l e .E Remova ble fuse unit assembly :=.;q�� Removable trip unit Load End w AQB B reaker with Over- C u rrent. S h o rt C i rcuit Trip a n d F u ses ww Westing house E lectric Corporation Low Voltage B reaker D ivision Beaver, Pennsylvania 1 5009 L,'k - Minimum C i rcuit B reaker H a n d l e Lock i n g Device lec Wiring D i agram Wiri ng as Shown is for a 3 Pole Breaker F o r 2 Pole B reaker O m it M iddle Pole tri � - R. Min. load End Reverse position of lock to prevent breaker from opening (Not supplied with circuit breaker ) s lot �· <D :!' c. Types AQB- LF1 00, 1 00 Amperes Maximum, Types AQB- LF250, 250 Amperes Maximum 500 Volts Ac, 1 00,000 Amperes I . C. October, 1 978 S u persedes Price List 29- 220, pages 37 -38, dated February 1 7, 1 969. O u t l i n e D i mensions A O B - LF250 B reakers f -20 Mig. s c rews Warning nameplate n o m e p1 a te _:_����t='��=i) Page 37 AB DE-ION® Circuit Breakers for Naval Shipboard Use Line E n d an Frome Tec h n i ca l Data 29-220 ua ls Mai led to: E, C/1 905/ P L .c om 8 West i n g house E l ectric Corporati o n Low Voltage Breaker D ivision Beaver, Pennsylvania 1 5009 T Support blocks ore not suppl i e d w 1 t h b r e a k e r , but m u s t be ordered separately refer to dwg 313C680. a l l po r t s n e cessa r y to conver t a b k r are 1nc lude d ar tM 4 Nuts and I wa s he r s ,------,=+-- s u p p l i e d w1lh stud Load End lP D r i l l i n g Plans For Terminal Mounting B locks ca ( and nuts supplied with terminal lec Flat woshers,lockwoshers mounting blocks w .E Typical Wiring Diagrams Wiring as Shown for 3 Pole Breaker For 2 Pole Breaker Omit M iddle Pole Removable ww tr t p u n i t Recommended m i n i mum distance be t ween u n i t s Line E nd _9it_-----l tri "*���H Front S heet D r i l l i ng Template '--+--1'--.P:.>l A Q 8 Breaker wi t h ..---±---±----"� over cur rent , s h or t '--'!'-��'--' c i r c u i t t r i p and f uses of breaker Bottom o f mtg block Bottom of breaker It Di o. 6 holes Load E n d H a n d l e locking Device ( N ot Supplied With Circuit Breaker) When U nder-Voltage Release is Provided IS � ,A When Shunt Trip and Auxil iary p rOVI. d d . h S WltC . A and 8 au•. l e ads switch 3 l8" lon11 YY Y A II Shunt t r i p 2 l eoods 1 8 " l o ng � Note: The a u x . s w i t c h m u s t be u s e d w i t h e a c h shunt t r ip, connect one side of s h u n t t r i p i n sertes w i t h "A11 c o n t a c t (closed when breaker i s c losed ) of a u x. . switch when connecting f o power supp l y . .c om Tec h n ical Data 29-220 Page 38 C h aracteristic T r i p p i n g C u rves I I II 11 1 1 1 1 Percent of Trip E l e m en t Rating Tr i pping T1me 25 Seconds ! 2 5 % Less Than 1 Hour More Than 1 Hour 600 225 1 30 1000 1 00 Operating Characteristics Therrnol Magne t i c and Current Li m i t i n g Fuse 5 0 ° C Ambient Cold S t a r t A c Instantaneous Tr i p Range of 2 5 0 Amp. Trip Unit Shown 6 50 to 1300 Amp. - - - 1 5 0 0 to 3000 A m p. See Table For Instantaneous Range of Other Trip Unit \ 40 50 30 20 � , I'\ 10 5 4 3 2 5 4 3 2 1\ .I .05 03 .0 2 .0 I 100 300 � L :� � 600 \ 1200 100 11 1 1 I I 1\� 50 40 30 20 2 2 5 Amp 1-- 1-- 150 Amp 1 2 5 Amp. I� I� p t-: 3000 - 5 4 3 2 5 4 3 2 I 03 .02 \\� 30000 10000 100000 .0 I lec I\ 'll � 100 300 600 3.0 2.5 2.0 7 5 Amp 1.0 2 5 Amp. 15 Amp. \ \ ,\ \ l\ l\ � \ \ " 3000 30000 10000 100000 vI-" 1.5 100 Amp. � � �'1\ 1200 Percent Rated Current .E w \ � � \ II II 05 \\ 3.5 I I 50 A m p. I� H I �\ Westing house Electric Corporation Low Voltage B reaker Division Beaver, Pennsylvania 1 5009 ww -- � I I Operating C h a r a c t e r i s t i c s The r m a l Moqnetics a n d Current L i m i t i ng Fuse 50° Ambient - Cold Start Ac Instantaneous Trip at 1 2 0 0 to 1 4 0 0 % Ra t i n g - - Instantaneous Tr i p at 600 to 7 0 0 % Ratinq ,� II I II tri Percent Rated Current 250 Amp r:::::= 1 7 5 Amp - I I 1\ 500 400 300 200 Tri p p i n g Time 2 5 Seconds! 2 5 % Less Than 1 Hour More Than 1 Hour 600 225 1 30 10 I I I Percent of Tr 1 p E l e m e nt R o t � n g r-- * 0 0.5 tM 1\ 500 400 300 200 1\. ar 1 000 5000 4000 3000 2000 AQB-LFIOO lP 5000 4000 3000 2000 10000 To determ ine the trip u n it rating to be used, when the load cu rrent and a m bient are known, m u ltiply the load current by the factor obtained from the cu rve below for the known ambient. The result will be the ideal trip u n it rati ng. H owever, since trip u n its are furnished only with standard rati ngs as per Navy spec., select the standard u n it trip whose rating is equal to or one rating higher than the ideal rati ng. an AQ B - L F 250 ca 10000 A O B - LF1 00 B reakers ua ls A O B - LF250 B reakers 0 � 0 o Ambient Temperature, OC 10 20 30 40 50 60 70 80 90 100 Tec h n ical Data 29-220 Page 39 Types AOB-A1 601 , N QB -A 1 6 0 1 500 - 1 600 Am peres; 5 0 0 Volts, 60 H z Ac, 75,000 Amperes I . C . August, 1981 S u persedes Tech n ical Data 29-220, pages 39-40, dated October, 1 978 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls M a i l ed t o : E , C/ 1 905/PL .c om 8 West i n g h ouse E lectric C o rporat i o n Low Voltage Breaker Division B eaver, Pennsylvania 1 5009 A O B -A1 601 a n d N Q B-A1 601 N avy B rea kers lP ar tM an 500-1 600 A m peres, 500 Volts A - c , 60 Cycles O n ly, 3 - P o l e , 50°C A m bient I nterru pti n g Rating : 75,000 Amps. A-c (Without Delayed I n stantaneous) 50,000 A m ps. A - c (With Delayed I nsta ntaneous) Specificat i o n : M I L- C - 1 7361 ( M od i f i e d ) C l ass : H i S h ock M I L-S -901 ( M od i fied ) V i b ration: M I L-STD - 1 67 M aterial and Workmans h i p : M I L- E-91 7 Test Report N u m be r : 2085 Type Continuous I n stantaneous Trip Setting Ampere A- c Amperes Rating High ca Breaker Only, consists o f : Frame i lncludes Stabs) Style N u m ber I National Stock N u m ber lec Low tri N et Pri ces See Price List 29 - 020 3 Pole, 500 Volts, 60 Cycles A-c Without Delayed Instantaneous Trip 600X 600XM BOOX 1 000X 1 200X 1 400X 1 600X 1 600 2000 4000 2000 2000 2000 4000 4000 6000 1 2000 6000 6000 6000 1 2000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 None 3720522G02 Assigned 3720522G02 3720522G02 3720522G02 .E AQB AQB AQB AQB AQB AQB AQB NQB A com plete breaker consists of a breaker plus mounting base and is available with n u mer ous attachments such as electrical operator, shunt trip, undervoltage release and auxil iary switches to perform varied auxil iary func tions. Com plete Breaker Breaker Only Trip u nits for these breakers have an adjust able instantaneous trip and are listed with and without delayed instantaneous trip for system coordination. Trip Uni t Style N umber National Stock N umber 3720523G01 3720523G03 3720523G07 3720 524G03 None 3720524G05 Assigned 3720524G07 3720524G09 3720524 G 1 0 With Delayed Instantaneous Trip (XT1 - M in. Time Delay .041 7 - .0458 Sec.) AQB AQB AQB AQB AQB 500XT1 800XT1 1 OOOXT1 1 200XT1 1 600XT1 2000 2000 2000 2000 4000 6000 6000 6000 6000 1 2000 1 3720522G02 3720522G02 3720522G02 None 3720522G02 Assigned 3720522G02 1 374021 1 G01 374021 1 G07 374 021 2G03 None 3740212G05 Assigned 3740212G09 w With Delayed Instantaneous Tri p (XT2 - Max. Time Delay .0708 - .0750 Sec.) ww AQB 500XT2 AQB 800XT2 AQB 1 200XT2 AQB 1 600XT2 2000 2000 2000 4000 6000 6000 6000 1 2000 3720522G02 3720522G02 3720522G02 None 3720522G02 Assigned AOB-A 1 60 1 circuit breakers are designed for installation i n switchboards for protec tion of generators and feeder and branch circu its. 3740221 G01 3740221 G07 3740222G05 None 3740222G09 Assigned N QB -A1 601 Breakers have a conti nuous rati n g of 1 600 a mperes. They are used only as discon nects since they do not have an automatic trip device. Note: Breakers with ratings other than those l isted above are considered as special and full descriptive data must be provided. 400 cyc l e breakers a re not ava i la b l e . Page 40 Mounting Base® N et Weig hts Optional Additions® Undervoltage Release CD : M o unts in rig ht pole only. ua ls Shunt Trip CD : M o u nts i n right pole o n l y . Has mo mentary rating o n l y ; co i l leads m u st be wi red i n series with 1 A co ntact of auxil i a ry switch. Description B reaker Only AOB NOB B reaker Frame ( A O B a n d N O B ) Trip U n i t AOB NOB M ou nting Base Only E lectrical Operator, 1 1 5 Volt E lectrical Operator, 450 Volt S h u nt Trip U ndervoltage Release Auxi liary Switch Cable Con nector an Auxiliary Switch: M o u nts i n left po l e only. 4 contacts, a n y co mbi nation of A's a nd B's, (suppl ied as 2A a n d 2B u n less specifi e d ) 8 contacts, a n y combi nation o f A's and B's, (suppl ied a s 4A a n d 4B u n l ess specified) tM Automatic Reset Switch@ F o r use with m ot o r o perator w h e n an auto matic reset fu nction is req u i red. Factory i n stal led o n ly. Cable Connector: M o u nts to bus co n n ector fo r cable co n nectio n . Each lug accepts four cables, 600 M C M m a x . 1 lug req u i red per bus connector. Style N u m be r : 505C706G03 Weight, Lbs. 1 51 1 48 1 28 23 20 75 27 35 % 1% 1% 3 O rd e r i n g I n formation When ordering Westingh ouse N avy c i rcuit breakers consult the check l ist below to make sure you have provided correct i nfor mati o n . You should specify: ar For switchboard mounting. I nc l udes back connectors for switchboard bus a nd male stabs to engage breaker. M atc hing stabs are supplied with breaker frame. .c om Tec h n i ca l Data 29-220 Style N u m ber: 373 D307G02 1 . Qu a ntity, West i n g house style n u m b e r a n d N a t i o n a l stock n u m ber of: Fungus, Moisture Resistant Treatment: (a) B reaker frame and trip u n it. (JAN-C- 1 73 o r M I L-V- 1 73) : If s pecified, con ( b ) M o u nting base. tact West i n g h ouse. External pa rts a re coated; (c) Spare breakers or trip u n its. ( Usually trip u n its a re not treated. one req u i red for each ten u n its or Drawings fraction thereof of each current rati ng.) M a ster p l a n : 900J442 ( d ) I nstruction books. S h eet 1 of 4: Breaker O n l y a n d W i r i n g d i a g ra m s 2. S h i pment S h eet 2 of 4 : T r i p U n it, Cu rves and Attach Spec ify transportation means, method of ments pa ckag ing and preservation a nd req u i red S h eet 3 of 4: M o u nt i n g Base and Ca bl e shi pping d ate. Co n n ectors S h eet 4 of 4 : Motor O p e rator 3 . D rawings Specify q u a ntity of outline or master plan Individual Reproductions: When req u i red, d rawings required. reproductions of sheets 1 thru 4 of m a ster plan 900J442 can be ordered as follows: 4. I n spect i o n Type Reproduction I nd i cate whether N avy inspection is re Cronoflex (Mylar Reproducible) q u i red at factory prior to shipment. lec tri ca lP Electrical Operator® <B Sepia (Brown Paper Reproducible) Prints (Paper) .E Technical Manua l : NAVS H I PS No. 0962-0 1 45000. This booklet per M I L- M - 1 507 1 . When req u i red, o rd e r BVR-TM-576. M o u nts to front of breaker for remote opera tion. 450 volt Ac rating util izes a tra nsfo r m e r i n conjunction w i t h a 1 20 v o l t m otor. I f auto Dimensions: Pages 4 1 , 42, 43. matic reset i s desi red, o rd e r the circuit breaker with optional Automatic Reset Switch Characteristic Curves: Pages 44, 45. (See Optional Add iti ons) CD Breaker can be supplied with e1ther shunt tnp or under Style Number(i 1 20 V A-c 450 V A-c 1 37 1 D38G01 1 37 1 D38G03 ww w Rating National Stock Number None Assigned voltage release, but not both. ® Can be field mounted. <t Changed smce prev1ous 1ssue. �. :J '" c. c � i:n Page 41 Types AQB-A1 60 1 , N Q B -A1 601 500 - 1 600 Am peres; 500 Volts, 60 H z . Ac. 75,000 Amperes I . C . October, 1 978 Su persedes Price List 29- 220, pages 4 1 -42, dated February 1 7, 1 969 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls Mailed to : E, C / 1 905/ P L .c om Tech n i ca l Data 29-220 Westi n g house E l ect ric Co rporat i o n Low Voltage Breaker Division Beaver, Pen nsylva nia 1 5009 A Q B a n d N Q B C i rcuit B reaker Frame O u t l i n e D i mensions N O B -Same except for tnp unit nameplate. Front Panel Cutout ar tM an It of Breaker lP }_.f---+- Removable Handle Extension Supp lied w1th Breaker Swi t Chboard Front Pane i � E 9 - 1 - - - -_ _ lec tri ca Attachment Leads are brought out through 0ne or more of these Openmgs as Requtred in th1s Stde for Shunt Trip or Under voltage Releose and Oppostte S1de for Au xi ltory Switches, Leads Extend Mintmum of 18 Inches from Breaker � M in i mum .r---g -----11-1 --- F�F�g;:-::::= :: ::;t---Tt .E W i r i n g D i agrams AQB NQB Line i L1ne rr\ rr) r w ' --- -· - · - I ' ww L - - - - - - - - - - _ _ _I Load 1_ _ _ _ _ _ _ _ - Reproduced From Drawing Load 900J442 - -- � t t -· 1��:�: ;- � ) ) ) i d r Sw1 tches 16 Leads 18 I nches Long -' Sheet When undervoltage release and auxil iary switches are provided �-' 4"A" ' c ·- ! ill : dik ' Furntshed wtth a l l Breakers for Manual Clos�ng and Opemng 1 of 4 - - - - - - - -- ���\ I � , -- ___ : ;_ _ _ _ _ · __ _ · . � ' I 4 _ _ _ _ _ _ _ , 1 Undervoltoge ; Release 2 Leads 18 Inches Long _ -� When shunt trip and auxil iary switch are provided iJt;�;r-��rn �/ ) ·w � 1 8 1 nches Long ::::C ) : ' ' ' ; Shunt Tr�p 2 Le d 18 ln h s Long �: N ote · The auxil iary switch must be used with each shunt trip. Con nect one side of shunt trip i n series with "A" contact ( c l osed when breaker is cl osed) of auxi l i ary switch when con necting to power supply. .c om Tec h n ical Data 29-220 Page 42 M o u n t i n g Base O u t l i n e D i mensions ua ls Top View 1 an Sw1tch board Bock Panel �------ 12� ------- tM 0 0 0 Side View � 0 1 0 8 Holes j a l l Connectors may ca lP ar ( M o u nt 1 n g Bose) Sw1tchboord M ou n t 1 n g Angle �-1 6 To p 4 Holes tri ( B reaker Mount m g ) lec Front View Cutout 'T'� � .E w ww Reproduced From Drawing Outl1ne of Mount1ng Bose 't of I I 11 To p E n d of Breaker 2 32/ --r Hi I L--4 ti2 ll_I I i 1 , �-:: Rod1us ,.__ 8 Sheet 3 o f 4 With cable connectors style 505C706G03 l u g capacity-four 600 M C M cables per lug Breo ker 1 3 32 j 900J442 M ounting Base F ront Panel Cutout For Switchboard Back Panel ' 67 ' 6 z32r 3 Holes for Megger Test 5 -i6 0 1 omet e r .c om Technical Data Westinghouse Electric Corporation Distri bution a n d Control Busi ness U n it E l ectrical Com ponents Division Pittsbu rg h , Pen nsylvania, U .S.A. 1 5220 Types AQB-L400QF, AQB-L4000M ; 1 50,000 Am peres I.C. a n d AQB-LL4000S; 1 00,000 A m p e res I.C. 250-400 Amperes; 500 Volts 60 H z Ac Mounting Block Undervoltage Release ( Left-Pole Only) UVR and Circuit Breaker m u st be o rd e red as a n i nteg ral u n it Plug-in Mounting Block, Rear Connected, Complete (Required one per load or line end) Mounting Block, Molded Base Only (For mounting a front con nected circuit breaker, or as a replacement part) Westinghouse Style Number 1 230C81 G01 Type 1 230C81 G05 AQB-L400QF w1th 1 1 5 V Ac Undervoltage Release Mechanism • �Style estmghouse N u mber 1 230C83G 1 5 Switchboard Mounting Breaker frame i nclu des m o u nting h a rdware. Stud projections a re mou nted o n the rea r of the breaker for plugging i nto fem a l e s l i p connectors of term i n a l mou nting block assembl ies. 1 230C83G16 Handle Lock (For s h i pboard m a i ntenance u se only) order sty l e n u m be r 1 7201 01 . tM AQB-L400QF with 450 V Ac* Undervoltage Release Mechanism I 1 230C81 G04 Front Connected Terminal (Required three per line or load end) 504C497G01 AQB-L400QF with 250 V De Undervoltage Release Mechanism 1 230C83G 1 8 AQB-L400QM with 1 1 5 V Ac Undervoltage Release Mechanism 1 230C83 G 1 9 AQB-L400QM with 450 V Ac* Undervoltage Release Mechanism 1 230C83G20 AQB-L400QM with 120 V De Undervoltage Release Mechanism 1 230C83G21 AQB-L400QM with 250 V De Undervoltage Release Mechanism 1 230C83G22 AQB-LL400QS with 1 1 5 V Ac Undervoltage Release Mechanism 1 230C83G 1 1 AQB-LL400QS with 450 V Ac* Undervoltage Release Mechanism 1 230C83G 1 2 AQB-LL400QS with 1 20 V De Undervoltage Release Mechanism 1 230C83G 1 3 1 220C86G08 1 220C86G09 AQB-LL400QS with 250 V De Undervoltage Release Mechanism 1 230C83G14 Auxiliary Switch 1 a/1 b 1 1 5-450 V Ac 2a/2b 1 1 5-450 V Ac 1 a/1 b 1 20 V De 2a/2b 1 20 V De 1 a/1 b 1 1 5-450 V Ac and 1 a/1 b 1 20 V De Combination 1 220C86G01 1220C86G02 1220C86G05 1220C86G06 1220C86G07 Shunt Trip Type w .E 1 1 5 V Ac/28-1 20 V De Shunt Trip and 1 1 5-450 V Ac Auxil iary Switch 1 1 5 V Ac/28-1 20 V De Shunt Trip and 1 20 V De Auxiliary Switch 450 V Ac Shunt Trip and 1 1 5-450 V Ac Auxiliary Switch 450 V Ac Shunt Trip and 1 20 V De Auxiliary Switch ww 1 220C86G03 1 220C86G04 lec Shunt Trip and 1 a/1b Auxiliary Switch (Left Pole Only) Combination tri Westinghouse Style Number Shunt Trip (Left-Pole only) (Includes built-in cutoff switch) 1 1 5 V Ac/28 to 1 20 V De 450 V Ac Only lP Westinghouse Style Number ca Type 1 220C86G 1 0 1220C86G 1 1 1 230C83G 1 7 ar Male Slip Connectors (Replacement part, three per kit) AQB-L400QF with 1 20 V De Undervoltage Release Mechanism Auxiliary Switches AB DE-ION® Circuit Breakers for Naval Shipboard Use an Type Page 43 ua ls J u l y 1 991 S u persedes Technica l Data 29-220, pages 43-44, dated April 1 991 M a i l ed to : E , D, C/29-200A 29-220 Fungus - Moisture - Resistance Treat ments: (JAN-T- 1 52; JAN-C- 1 73 ; M I L-V- 1 73) If specified contact Westi n g h o u se. External parts a re coated. Technical Manual: When requ i red order 1 240C33H0 1 . Portable Test Kit - Can b e used to function ally test the breaker fo r ove rload a n d s h o rt circu it, w h i l e breaker is m o unted. When req u i red o rd e r catalog n u m be r STK2. Individual Reproduction: When requi red reproduction of outl i n e d rawings and certifi cation s heets can be o rdered a s follows : Item 1 2 3 Description Outline drawing and drilling plan on vellum Certification data on vellum Reproduction of items 1 and 2 Repair Parts: Net Weight: *Using externally-mounted step-down transformer supplied Item Circuit Breaker Motor Operator Mounting Block Front Connected Terminals (Set of Three) Portable Test Kit Weight 30 lbs. 22 lbs. 10 lbs. 1 lb.-10% ozs. 12 lb.-14% ozs. .c om Tech nical Data 29-220 w .E lec tri ca lP ar tM an ua ls Page 44 ww Westinghouse E l ectric Corpo ration Distribution and Control Busines s U n i t E l ectrical Com ponents Division Pittsburgh, Pennsylva n ia , U . S .A . 1 5220 J u ly 1 991 .c om Cl Westinghouse Electric Corporation Distribution a n d Control Busi n ess U n it Electrical Components Division Pittsburgh, Pen nsylva n i a , U .S.A. 1 5220 July 1 99 1 Su persedes Technical Data 29-220, pages 45-46, dated Apri l 1 99 1 M a i led to : E, D, C/29-200A Curve Tolerance Applies Over Temperature Range of AB DE-ION® Circuit Breakers for Naval Shipboard Use Navy Type AQB-L400QF Circuit Breaker -'--'--'-H-'-'f---i-- 1 Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. �� ���:3]!tt=fiE��� � lP ar - 20 Deg. C. to + 70 Deg. C. tM - 3000 ji Rating Plug: 2500 Page 45 ua ls • Navy Type AQB-L400QF Circuit Breaker 29-220 an • Types AOB-L4000F, AQB-L400QM ; 1 50,000 Am peres I .C. a n d AQB-LL400QS; 1 00,000 Am peres I .C. 250-400 Amperes; 500 Volts 60 Hz Ac Tech n ical Data I �-=: �: �= 10 �� - ____:_ -:--=�_ w±:1=�==��:t;:H=ttr=r==J=-1.=:�:---=-- � -:--� �� - · Short Delay H1gh Sett�ng - - � -_ -� - 0 ca {1500Al P.ck Up --H . - -� - I·' --- .E lec tri -+--+-f-+-'+-t--'-+-'-: ww w Time-Current Curves for AOB-L4000F Circuit Breaker with 250 Ampere Rating Plug Time-Current Curves for AOB-L4000F Circuit Breaker with 300 Ampere Rating Plug .c om Technical Data 29-220 Page 46 • Navy Type AOB-L4000F Circuit Breaker Rating Plug: 3500 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 10 Deg. C. iOOO --• Navy Type AOB-L4000F Circuit Breaker ' -�· I -: l�OIJ ::; t ;_ --::=-�� _ ---_:______;:_____._-----:--;--:- t .!.___ � - --t · • · �- t ----+---+ · •+-t- 100 --- t � 50 :§ --- · ---+--+----1 lec tri ca lP ar tM _.____.__. _= : �� � � - � - �-- ·-�--· • • · 30 t �---· . . L 2o Curve Tolerance Applies Over Temperature Range of - 2 0 Deg C to + 70 0eg C an j'-" 500 ua ls • Time-Current Curves for AQB-L400QF Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AOB-L400QF Circuit Breaker with 350 Ampere Rating Plug ww w Westi n g h ouse E l ectric Corporation Distri bution and Control Busines s U n it E lectrical Components Division Pittsburgh, Pen n sylva nia, U . S .A. 1 5220 July 1 991 J u l y 1 99 1 S u persedes Tec h n i ca l Data 29-220, pages 47-48, dated April 1 99 1 M a i led to : E , D, C/29-200A • 29-220 Page 47 AB DE-ION® Circuit Breakers for Naval Shipboard Use lP ar tM an Navy Type AQB-L400QM Circuit Breaker Tec h n ical Data ua ls • Types AQB-L400QF, AOB-L400QM ; 1 50,000 Am peres I.C. a n d AQB-LL400QS; 1 00,000 Am peres I.C. 250-400 A m peres; 500 Volts 60 Hz Ac .c om Westinghouse Electric Corporation Distri bution a n d Control Busi ness U n it E l ectrical Compon ents Division Pittsburgh, Pennsylvania, U . S.A. 1 5220 Navy Type AQB-L400QM Circuit Breaker Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. - < -+-- ---+--• · · -· - § .E lec tri ca ---+----+ . , ___, 3 ' ww w Time-Current Curves for AQB-L4000M Circuit Breaker with 250 Ampere Rating Plug Time-Current Curves for AOB-L4000M Circuit Breaker with 300 Ampere Rating Plug .c om Technical Data 29-220 Page 48 • Navy Type AOB-L4000M Circuit Breaker Navy Type AOB-L4000M Circuit Breaker ua ls • Rating Plug: 4000 an Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. d -i � � � '>0 � - ; ' · � aa - --� - -� - �� -� � :-� ---� - ��-:__· ·�----1----+-+->- - - - . -� _ : :=:tr =- --+ -- I· 00 +- ----+ -�-.--+--- � - � § tri ca lP ar · - tM J �� � + - 'I -+f-. iOO ++��--+---- : t: i �1 � ! ; lec �-=�- I �I I I r II [ Time-Current Curves for AOB-L4000M Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AOB-L4000M Circuit Breaker with 350 Ampere Rating Plug ww w Westi ngh ouse E l ectric Corporation Distribution a n d Control Bu si ness U n it Electrical Compone nts Division Pittsburg h , Pen n sylva n i a , U . S.A. 1 5220 July 1 991 J u ly 1 99 1 S u persedes Technical Data 29-220, pages 49-50, dated April 1 99 1 Mailed to : E, D, C/29-200A • " --+-+ Page 49 AB DE-ION® Circuit Breakers for Naval Shipboard Use Navy Type AQB-ll400QS Circuit Breaker Rating Plug: 3000 Curve Tolerance Applies Over Temperature Range of - 20 Deg. C. to + 70 Deg. C. ar JOO � - tM Rating Plug: 2500 Curve Tolerance Applies Over Temperature Range of - 20 De g. C. to + 70 Deg. C. 29-220 an Navy Type AQB-ll400QS Circuit Breaker Techn ical Data ua ls • Types AOB-L400, AQB-LL400 500 Volts Ac 400 Amperes M a x i m u m , 1 50,000, 1 00,000 Am peres I . C . , Respectively .c om Westinghouse Electric Corporation Distri bution a n d Control Busi ness U n it E l ectrical Compo nents Division Pitts burgh, Pennsylva nia, U . S . A. 1 5220 z - ------ 10• • �- �- . 1 -+--. 1 .E lec tri ca lP > ww w Time-Current Curves for AQB-LL400QS Circuit Breaker with 250 Ampere Rating Plug Time-Current Curves for AQB-LL400QS Circuit Breaker with 300 Ampere Rating Plug .c om Tech n i ca l Data 29-220 Page 50 • Navy Type AQB-LL400QS Circuit Breaker �� ----;-----:- --+ ____ _::::___ . • _J_ '00 ,;:: � -----+ ---+-- ---; -;-----+-' · +---i-----1 - .z • .j___J._..._. 0 0 � lec tri ca lP ar tM _ Circuit Breaker an Curve Tolerance Applies Over Temperature Range of -20 Deg. C. to + 70 Deg. C. 30UO t · /000 Navy Type AQB-LL400QS ua ls • 8 § §§§§§ � " :il >":i:5l§ Time-Current Curves for AOB-LL4000S Circuit Breaker with 400 Ampere Rating Plug .E Time-Current Curves for AOB-LL4000S Circuit Breaker with 350 Ampere Rating Plug ww w Westing house E l ectric Corporation Distribution and Control Busi ness U n i t Electrical Com ponents Division Pittsburgh, Pen n sylva n i a , U .S.A. 1 5220 July 1 99 1 J u ly 1 99 1 S u persedes Tech nical Data 29-220, pages 51 -52, dated April 1 99 1 M a i led to : E , D, C/29-200A �·'• --��� J I t=l ! ® �.' TFn � � � ,t=s 0 F l r. tt-"' l � 'u ....__, ll'i'J'[ �u { \_./ J J' ' L:t.J ( lec .E ---- 4'116 � Automatic Tripped 91 7132 ( II 'I I' ' C! 30� 1 o 1 9°rl. ' "Y�i 1 I@ I t 31/16 � / 55132 21!64 Jl 11/s t i Load v � t I .._�� � 11 1° 50' I Reset Max 37/s Radius � - t2311 6 +- w ( ! II IL v U t--" I On tri \L w 2 1J64 4 , . �,% I lP f+ 17/a <§I C! T J ca 627132 513/1 6 1 /s � $ ! <§I t1 _i_ ' I ! ' ar 103/1 6 '� l '- cp C! -f- - I --- Line - Pis AB DE-ION® Circuit Breakers for Naval Shipboard Use an � 18'11 6 16 Page 51 tM _j /I 1'132 29-220 ua ls - 2'14 - 1 Technical Data Types AQB-L400, AQB-LL400 500 Volts Ac 400 Amperes M a x i m u m , 1 50,000, 1 00,000 Am peres I . C . , Respectively Outline Dimension AQB-L400, AQB-LL400 ww .c om Cl Westinghouse Electric Corporation Distribution and Control Busi ness U n it E l ectrical Components Division Pitts burgh, Pen nsylva n i a , U . S . A. 1 5220 ! lll J 1t. i Front Surface of Mounting Panel 99/16 143 I 'I '! II Center Line of Circuit Breaker Handle i. ...j ] r--- 1 %2 ;F], � -18-- ? J Dimensions in Inches *Conductor Height for Front Connection JTI1 1.IlJ 53/1 6 1t ,· 29-220 Page 52 Outline AQB-L400, AQB-LL400 with Motor Operator @ 10 13116 16 0 ua ls )� I -I-0 27132 - 0 -i---f---,_____ 513116 -1 Q; @ I I Ql )� Load E nd 511 6·18 Mounting Hardware Dimensions in Inches ww w .E lec tri ca @ Off Reset Max. 14% ar +-- Auto matic Trip ped lP 6 @ an 1','32 @ tM �l @ 1 71311 6 Line End .c om Tech n i c a l Data Westi n g h ouse E l ectric Corporation Distribution and Control Business U n it E l ectrical Compo nents Division Pittsburgh, Pen nsylva nia, U . S .A. 1 5220 July 1 991 .c om Tech n ical Data Westinghouse Electric Corporation Distribution a nd Control B u s i n ess U n it Electrical Components Division Pittsburgh, Pen nsylv a n i a , U . S . A. 1 5220 Types AOB -A1 601 , N O B -A1 601 500-1 600 Amp eres; 500 Volts, 60 Hz Ac, 75,000 Amperes I . C . Page 55 AB DE-ION® Circuit Breakers for Naval Shipboard Use ua ls J u l y 1 99 1 S u p e rsedes Tech n i c a l Data 29-220, pages 55-56, dated April 1 99 1 M a i led to : E, D, C/29-200A 29-220 A Q B - A 1 601 and N Q B -A 1 601 N avy B reakers lP ar tM an Note: AQB-A1 601 are sold for replace ment only. They are no longer on the Navy Qualified Products List. ca tri List Prices See Price List 29-020 3 Pole, 500 Volts, 60 Cycles A-c Breaker Only, consists o f : Frame (I ncludes Stabs) Type Continuous I nstantaneous Trip Setting Ampere A-c Amperes Rating Low High Trip u n its for these breakers have a n adjust able instantaneous trip and are listed with and without delayed i nsta ntaneous trip for system coord i nation. Trip U n it National Stock N u m ber Style N umber 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 3720523G01 3720523G03 3720523G07 3720524G03 3720524G05 3720524G07 3720524G09 3720524G 1 0 lec Style N u m ber National Stock Number Without Delayed Instantaneous Trip 600X 600XM aoox 1 000X 1 200X 1 400X 1 600X 1 600 2000 4000 2000 2000 2000 4000 4000 6000 1 2000 6ooo 6000 6000 1 2000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 3720522G04 .E AQB AQB AQB AQB AQB AQB AQB N QB 2000 2000 2000 2000 4000 6000 6000 6000 6000 1 2000 1 3720522G02 3720522G02 3720522G02 3720522G02 3720522G02 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 1 374021 1 G01 374021 1 G07 37402 1 2G03 374021 2G05 3740212G09 5925-00-406-61 3 1 5925-00-1 02-6086 5925-00-727.757 4 w With Delayed Instantaneous Trip (XT2 - Max. Time Delay .0708 - .0750 Sec.) ww AQB 500XT2 AQB 800XT2 AQB 1 200XT2 AQB 1 600XT2 2000 2000 2000 4000 6000 6000 6000 1 2000 3720522G02 3720522G02 3720522G02 3720522G02 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 5925-0 1 - 1 05-4401 374022 1 G01 374022 1 G07 3740222G05 3740222G09 N O B -A1 601 Breakers have a continuous of 1 600 amperes. They are used o n ly as disconn ects since they do not have a n automatic t r i p device. rating N ote: B reakers with ratings other than those listed above are considered as special and fu l l descriptive data must be provided. With Delayed Instantaneous Trip (XT1 - M i n . Time Delay .041 7 - .0458 Sec.) AQB 500XT1 AQB 800XT1 AQB 1 000XT1 AQB 1 200XT1 AQB 1 600XT1 AOB -A1 601 circuit breakers are designed for insta llation i n switchboards for protec tion of generators and feeder a nd bra nch circuits. A complete breaker consists of a breaker plus mounting base and is ava ilable with n u mer ous attachments such as electrical operator, shunt trip, u ndervoltage release a nd auxil iary switches to perform varied a uxil iary func tions. Complete Breaker Breaker Only 500-1 600 Amperes, 500 Volts A - c, 60 Cycles Only, 3 - Pole, 50°C A m b i e n t I nterrupting R ati n g : 75,000 A m ps. A - c (Without Del ayed I nsta ntaneous ) 50,000 A m p s . A - c (With D elayed I n stantaneous ) S pecificat i o n : M I L- C - 1 7361 C l ass : H i S h ock M I L- S - 901 V i b ration: M I L- S T D - 1 67 M aterial a n d Work mansh i p: M I L- E -91 7 5925-00-727-7555 5925-00-1 03-4248 400 cycle breakers are not ava i l a b l e . Page 56 Mounting BaseCD .c om Technical Data 29-220 N et Wei g hts Optional AdditionsCD ua ls Shunt Trip@ : M o u nts in right pole only. Has momentary rating only; coil leads m u st be wi red in series with 1 A contact of aux i l ia r y switch. Description Undervoltage Release@ : M o u nts in right pole only. Electrical Operator, 1 1 5 Volt Electrical Operator, 450 Volt S h u nt Trip U ndervoltage Release Auxil iary Switch Cable Con nector an Auxiliary Switch: M o u nts i n left po l e only. 4 contacts, a ny co m b i nation of A's a nd B's, (suppl ied as 2A a nd 2B u n less specified) 8 contacts, a ny combi nation of A's and B's, (suppl ied a s 4A and 4B u n l es s s pecifi ed) Breaker Only AOB NOB Breaker Frame (AOB and N O B ) Tri p U n it AOB NOB M ounting Base Only Cable Con nector: M o u nts to bus connector fo r cable co n nection. Each lug accepts fo u r cables, 600 M C M max. 1 l u g req u i red per bus connector. Sty l e N u m be r : 505C706G 03 1 51 1 48 1 28 23 20 75 27 35 % 1� 1% 3 O rd e r i n g I nformation When ordering Westing house N avy circuit breakers consult the check list below to make sure you have provided correct infor mation. You should specify: ar For switchboard mounting. I n cludes back connectors for switchboard bus and male stabs to engage breaker. Matching stabs are supplied with breaker frame. tM Automatic Reset Switch For use with m otor operator w h e n an auto matic reset function is req u i red. Factory i n stal led o n ly. Weight, Lbs. Style N u m ber: 373D307G02 1 . Q u a ntity, West i n g h o u se style n u m b e r a n d N a t i o n a l stock n u m be r of: Fungus, Moisture Resistant Treatment: ( a ) B reaker frame and trip u n it. (JAN-C- 1 7 3 or M I L-V- 1 73) : If specifi ed, con (b) M ounting base. tact Westi ng h ouse. External parts are coated; (c) Spare breakers or trip u n its. ( Usua lly trip u n its a re not treated. one required for each ten u n its or Drawings fraction th ereof of each current rating.) M a ste r p l a n : 900J442 (d) I nstruction books. S h eet 1 of 4: Breaker O n l y and W i r i n g d i a g ra m s 2. S h i pment S h eet 2 of 4 : T r i p U n it, Cu rves and Attach Specify transportation means, method of ments packag i ng and preservation and req u i red S h eet 3 of 4 : M o u nt i ng Base and Cable shippi n g d ate. Co n n ectors S h eet 4 of 4 : Motor Operator 3 . D ra w i n g s Specify quantity of outl i n e or master plan Individual Reproductions: When req u i red, drawi ngs required. reprod u ctions of sheets 1 thru 4 of m a ster plan 900J442 can be ordered as fol l ows: 4. Inspection Type Reproduction I n d i cate whether G overn ment Sou rce Vellum inspection is req u i red at factory prior to Prints (Paper) s h i pment. .E lec tri ca lP Electrical OperatorCD Technical Manual: NAVS H I PS No. 0962-0 1 45000. This booklet per M I L-M- 1 507 1 . When req u i red, o rder BVR-TM-576. M o u nts to front of breaker fo r remote o pera tion. 450 volt Ac rating uti l izes a tra nsfo rmer Dimensions: Pages 57, 58, 59 i n conjunction with a 1 20 volt m otor. If auto matic reset is desired, o rder the circuit Characteristic Curves : Pages 60, 61 breaker with optional Automatic Reset Switch (See Opti o n a l Additions) CD Can be field mounted. w Rating V A-c V A-c ww 1 20 450 Style Nu mber 1 371 D38G06 1 371 D38G08 ® National Stock Number None Assigned Westi n g h o u se E l ectric Corporation D i st ri b uti on and C o nt rol B u s i ness U n it E l ectrical Compon ents Division Pittsburgh, Pennsylva n i a , U . S . A. 1 5220 Breaker can be supplied with either shunt trip or undervoltage release, but not both. July 1 991 Tech n ic a l Data 29-220 J u ly 1 99 1 Su persedes Technica l Data 29-220, pages 57-58, dated Apri l 1 99 1 M a i led to : E, D, C/29-200A .c om Westinghouse Electric Corporation Distribution a n d Control Busi ness U n it E l ectrical Components Division Pitts b u rgh, Pen nsylvania, U . S.A. 1 5220 Page 57 Types AOB-A1 6 0 1 , N O B - A 1 6 0 1 500-1 600 Amperes; 500 Volts, 6 0 Hz. Ac. 75,000 Amperes I . C . ua ls AB DE-ION® Circuit Breakers for Naval Shipboard Use A O B a n d N O B C i rcuit B reaker Frame O u t l i ne D i mensions NOB-Same except fo r t r i p u n it n a m e p l ate. Front Panel Cutout an It of Breaker Top End of Breoker ar tM z !!. / 3� T 7� 32 1-+--___,f- Removoble Handle lP Extension Supplied w1th Breaker Swttchboord Front Panel lec tri ca Attachment Leads ore brought out through 0ne or more of these Opemngs as Requtred in thts Side for Shunt Trip or Under voltage Release and Opposite Stde for Auxiliary Switches, Leads Extend Mtmmum of 18 Inches from Breaker W i r i n g D i a g rams NOB r--rn 1 r) r) r : ���r\ r Line Line w _ _ _ _ _ ��= �u �f\ \ cW ·: :·- - : , ffi - -- - - . ww t L- - - -- - - - - - Lood I - -' 18 1nches Long I '- - Reproduced From Drawing - - - Load 900J442 - - - I - ' Sheet 1 of 4 EJ , Minimum Furntshed wtth a l l Breakers for Manual Closmg and Opening When u ndervoltage release and auxiliary switches are provided .E AOB 9161 ---+�E,r-----9 : Undervoltoge ; Release 2 Leads •• . -. : ; _ _ _ _ _ _ _ _ _ _ _ _ _ _: 18 Inches Long When shunt trip and auxiliary switch are provided - - ���:·:��� � - r r) r) - : �;: . ��� � llil"t:"' J Sw1tches = \ , Long ' ' ' �: e 18 ln h s Long Note · The auxiliary switch must be used with each shunt trip . Con nect one side of shunt trip i n series with "A" contact ( c l osed when breaker is closed) of auxil iary switch when connecting to power supply. .c om Technical Data 29-220 Page 58 M ou n t i n g Base O ut l i n e D i mensions c . c. ua ls Top View Jn. t----------------� 1 t==;T-'���=-=-=-=-=-=rr Sw1tchboord an Bock Panel 0 0 0 tM �------ 12� --------� Switc h board Mountmg Angle I al l Connectors may be Rotated 90° ca lP ar Side View � -16 To p 4 Holes tri ( B reaker Mount 1 n g ) lec Front View C utout Front Panel Cutout For Switchboard Back Panel ww w .E <t_ o f B r e o ker M o u nt i n g Base With cable connectors style 505C706G03 lug capacity-tou r 600 MCM cables per lug Reproduced From Drawing Outl1ne o f Mount1n g Bose 900J442 Sheet 3 of 4 July 1 99 1
© Copyright 2024