1 | Roof Fans DHS sileo / DVS sileo / DVSI sileo Roof fans DHS • • • • • • Electrical accessories High efficiency Speed-controllable Integral thermal contacts Excellent sound level S-ET/STDT p. 373 Extensive range of accessories Maintenance-free and reliable The DVS/DHS/DVSI sileo is well suited for applications requiring high air volumes at medium pressure and very low noise levels. These models have 3D profiled impellers with backward curved blades and external rotor motors. All motors are speed controllable by voltage. For speed controlling of the DVS/DHS/DVSI sileo roof fans with a frequency converter, an all pole sine filter is required. The motors are suspended on effective vibration dampers. DVS DVSI DVS/DHS/DVSI sileo... E4 / E6 / EZ: 1~ motor DVS/DHS/DVSI sileo ...DV / DS: 3~ with Y/D-connection for 2-speeds DHS with horizontal outlet. DVS with vertical outlet. DVSI has a 50 mm mineral wool insulation for lower noise levels. To protect the motors from overheating the sileo range motors are equipped with thermal contacts with external leads for connection to a TK triggering device. The casing is made from aluminum and the base frame from galvanized steel. Suitable for coastal applications. The impellers of the sileo types are manufactured from high-performance composite material with highly efficient 3D fan blade profile technology. RTRE p. 356 RTRD/RTRDU p. 357 REU p. 356 REE p. 357 S2S 160 p. 381 S-DT2 SKT p. 381 Technical data DHS/DVS/DVSI sileo 190EZ 225EZ 311EV 400DS 400DV 400E4 400E6 Art. no. DHS 36290 36369 36064 36121 36122 36123 36124 Art. no. DVS 36289 36370 36068 36099 36109 36100 36101 36291 36371 36079 36110 36111 36112 36113 V/50 Hz 230 1~ 230 1~ 230 1~ 400 3~ 400 3~ 230 1~ 230 1~ W 52.4 110 132 123 491 466 152 Technical data is relating to DVS Art. no. DVSI Voltage/Frequency Power Current Max. air flow R.p.m. A 0.231 0.466 0.574 0.255 1.21 2.32 0.654 m3/s 0.151 0.232 0.464 0.691 1.16 1.11 0.772 min-1 2337 2560 1342 779 1408 1344 896 Max. temp. of transported air °C 65 60 60 60 60 60 60 “ when speed controlled °C 65 60 60 60 60 60 60 42/34 44/36 33/25 46/38 46/38 36/28 6.5/6/12 13/14/19 21/25/41 24/28/42 24/27/44 21/23.5/42 B F B F F F F 44 44 44 IP 54 IP 54 IP 54 IP 54 3 4 – – 9 5 20 20 18a 16 6b 6b Sound pressure level DVS** Weight Insulation class, motor Enclosure class, motor Capacitor Wiring diagram p. 442-461 ** at 4/10 m. DHS +2 dB, DVSI -9 dB dB(A) 47/39 kg 5.5/5/7 µF 1.5 20 Roof Fans | Dimensions DHS 190-500 DVS/DVSI Ventilation accessories DHS/DVS/DVSI A øJ F B M20x1,5 G SSD p. 419 G C øD øI(4x) øD E FDS p. 420 øD E DHS 560-630 J L K ASK p. 418 øD E VKS p. 427 DHS sileo £A £B C øD £E £F G H øI J K L 190, 225 311 400 450-500 560-630 - - - 213 285 438 438 605 335 435 595 665 939 245 330 450 535 750 105 146 200 237 293 6xM6 6xM6 6xM8 6xM8 8xM8 10 10 12 12 14 ø417 ø540 ø720 ø830 £1100 150 250 330 490 535 30 30 30 30 30 DVS sileo 190, 225 311 400 450-500 560-630 £A 370 560 720 900 1150 £B 295 470 618 730 960 C 170 330 390 465 560 øD 213 285 438 438 605 £E 335 435 595 665 939 £F 245 330 450 535 750 G 105 146 200 237 293 H 6xM6 6xM6 6xM8 6xM8 8xM8 øI 10 10 12 12 14 J - K - L - DVSI sileo 190, 225 311 400 450-500 560-630 £A 497 690 874 968 1315 £B 295 470 618 748 960 C 179 369 439 479 600 øD 213 285 438 438 605 £E 335 435 595 665 939 £F 245 330 450 535 750 G 105 146 200 237 293 H 6xM6 6xM6 6xM8 6xM8 8xM8 øI 10 10 12 12 14 J - K - L - DHS/DVS/DVSI sileo 450DV 450E4 450E6 ASS p. 415 ASF p. 415 500DV Technical data is relating to DVS Art. no. DHS 36125 36126 36127 33356 Art. no. DVS 36102 36103 36104 33324 36114 36115 36116 33340 V/50 Hz 400 3~ 230 1~ 230 1~ 400 3~ W 683 659 280 1241 2.24 Art. no. DVSI Voltage/Frequency Power Current Max. air flow R.p.m. A 1.37 2.86 1.34 m3/s 1.51 1.46 1.04 2.08 min-1 1363 1305 939 1337 Max. temp. of transported air °C 60 60 60 60 “ when speed controlled °C 60 60 60 60 Sound pressure level DVS** Weight dB(A) 49/41 kg 29/38/53 49/41 40/32 53/45 32/40/56 28/38.5/53 30/48/62.5 F Insulation class, motor F F F Enclosure class, motor IP 54 IP 54 IP 54 IP 54 14 8 – 6b 6b 18a Capacitor Wiring diagram p. 442-461 **) at 4/10 m. DHS +2 dB, DVSI -9 dB µF – 16 Roof fans L H K 2 3 | Roof Fans 400 qv [m³/h] 2000 1500 1 DHS/DVS/DVSI sileo 190EZ 2 DHS/DVS/DVSI sileo 225EZ 3 DHS/DVS/DVSI sileo 311EV Roof fans 300 700 0 1000 2000 500 4000 300 200 100 5 1 100 1 0 2 3 0 0 0.2 2 3 0.4 0.6 0.8 1 4 1.2 qv [m³/s] qv [m³/h] 1000 2000 3000 4000 5000 6000 7000 8000 9000 1 2 3 600 4 Ps [Pa] 0 9538/9539/13058/13074/13224 Ps [Pa] 5000 400 200 800 qv [m³/h] DHS/DVS/DVSI sileo 400DS DHS/DVS/DVSI sileo 400DV, 450E4 DHS/DVS/DVS sileo 400E6 DHS/DVS/DVS sileo 450DV DHS/DVS/DVS sileo 450E4 1 2 3 4 5 600 3000 9487, 9467, 9515, 9504, 9316, 9204, 9326 1000 DHS/DVS/DVSI sileo 450E6 DHS/DVS/DVSI sileo 500DV DHS/DVS/DVSI sileo 500DS DHS/DVS/DVSI sileo 500E6 400 1200 0 4000 8000 1.6 qv [m³/h] 16000 DHS/DVS/DVSI sileo 560DV DHS/DVS/DVSI sileo 560DS DHS/DVS/DVSI sileo 630DV DHS/DVS/DVSI sileo 630DS 1 2 3 4 1000 12000 1.4 qv [m³/s] 800 600 400 200 1 3 200 2 4 2 0 0 0.5 1 DHS/DVS/DVSI sileo 1.5 2 0 2.5 3 1 4 qv [m³/s] qv [m³/s] 500DS 500E6 560DV 560DS 630DV 630DS Art. no. DHS 36128 36129 36131 36130 33361 33362 Art. no. DVS 36105 36106 36108 36107 33329 33330 Art. no. DVSI 36117 36118 36120 36119 33345 33346 V/50 Hz 400 3~ 230 1~ 400 3~ 400 3~ 400 3~ 400 3~ 1113 Technical data is relating to DVS Voltage/Frequency Power W 446 504 2246 692 3991 Current A 1.08 2.14 4.15 1.54 6.64 2.34 Max. air flow m3/s 1.4 1.52 3.13 2.1 4.45 2.75 R.p.m. min-1 918 889 1347 884 1355 854 Max. temp. of transported air °C 60 60 60 60 55 60 “ when speed controlled °C 60 60 60 60 55 60 38/30 53/45 43/35 62/54 46/38 30/40/56.5 63/69/78 51/64/92 65/87.5/110 65/70/93 Sound pressure level DVS** Weight dB(A) 42/34 kg 30/40/56.5 Insulation class, motor F F F F F F Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 12 – – – – 6b 18a 18a 18a 18a Capacitor Wiring diagram p. 442-461 ** at 4/10 m. DHS +2 dB, DVSI -9 dB µF – 18a 10817/10993/13067/13069 500 Ps [Pa] 500 0 13077/13078/13217 Ps [Pa] Quick selection Roof Fans | 4 Speed control 190EZ, 225EZ, 311EV 450E6, 500E6 400E6 400E4, 450E4 400DV/DS, 500DS, 560DS 500DV, 560DV 630DV + motor protection S-ET 10/STDT 16 400 0 100 200 Q [m³/h] 300 400 500 DHS/DVS/DVSI sileo 190 EZ 350 Electronic Two step - – – – S-DT2SKT S-DT2SKT S-DT2SKT 500 13078 Performance Transformer Five step high/low REU 1.5 REU 3 REU 1.5 REU 3 RTRDU 2 RTRDU 4 – 0 100 200 Thyristor Stepless REE 1 REE 2 REE 1 REE 4 – – – 300 Q [m³/h] 400 500 600 Roof fans Transformer Five step - RTRE 3 RTRE 1.5 RTRE 3 RTRD 2 RTRD 4 RTRD 14 700 800 DHS/DVS/DVSI sileo 225EZ 13077 DHS/DVS/DVSI sileo 400 300 Ps [Pa] Ps [Pa] 250 200 300 200 150 100 100 50 0 1 0 2 0.04 4 3 0.08 5 0.12 1 0 0.16 4 3 120 60 P [W] 5 40 20 5 Q [m³/s] Q [m³/s] P [W] 2 5 80 2 40 2 0 dB(A) Tot Frequency bands [Hz] 63 125 250 500 1k 2k dB(A) 4k 8k Tot Frequency bands [Hz] 63 125 250 500 1k 2k 4k 8k LwA Inlet 68 39 57 61 63 62 59 54 47 LwA Inlet 68 39 57 61 63 62 59 54 47 LwA Surrounding 69 40 58 62 64 63 60 55 48 LwA Surrounding 69 40 58 62 64 63 60 55 48 64 51 53 57 59 58 55 50 43 DVSI LwA Surrounding DVSI 64 51 53 57 Measurement point: 0.09 m³/s @ 167 Pa 59 58 55 50 43 LwA Surrounding Measurement point: 0.14 m³/s @ 245 Pa | Roof Fans Q [m³/h] 500 1000 1500 2000 200 13219 300 0 DHS/DVS/DVSI sileo 311EV 0 400 Q [m³/h] 1200 1600 800 2000 2400 DHS/DVS/DVSI sileo 400DS 13076 5 250 150 Ps [Pa] Ps [Pa] 150 100 100 50 50 0 1 0 2 3 0.2 4 5 1 0 0.4 3 2 4 5 0.6 Q [m³/s] 180 P [W] P [W] 160 5 120 5 100 80 40 2 1 0 0 dB(A) Tot Frequency bands [Hz] dB(A) 63 125 250 500 1k 2k 4k 8k Tot Frequency bands [Hz] 250 500 1k 2k 4k 8k LwA Inlet 65 52 54 58 60 59 56 51 44 LwA Inlet 55 44 48 47 49 46 41 41 26 LwA Surrounding 67 54 56 60 62 61 58 53 46 LwA Surrounding 55 34 42 52 48 47 42 42 27 46 25 33 43 39 38 33 33 18 DVSI 125 51 51 53 51 45 38 36 30 0 Q [m³/h] 2000 1000 Measurement point: 0.38 m³/s @ 94 Pa 3000 4000 500 13050 500 LwA Surrounding DHS/DVS/DVSI sileo 400DV 300 300 Ps [Pa] 400 200 200 100 100 1 0 0.2 0.4 2 0.6 3 4 Q [m³/h] 2000 1000 3000 4000 DHS/DVS/DVSI sileo 400E4 400 0 0 5 1 0 0.8 2 3 4 13005 58 Measurement point: 0.28 m³/s @ 167 Pa Ps [Pa] 63 DVSI LwA Surrounding 5 Q [m³/s] 500 500 5 P [W] P [W] Roof fans 200 2 250 0 dB(A) 5 250 2 0 Tot Frequency bands [Hz] 63 125 250 500 1k 2k dB(A) 4k 8k Tot Frequency bands [Hz] 63 125 250 500 1k 2k 4k 8k LwA Inlet 72 48 68 67 63 57 54 49 47 LwA Inlet 66 36 58 62 61 56 54 50 51 LwA Surrounding 72 49 70 64 64 62 57 51 49 LwA Surrounding 68 37 57 61 63 61 57 52 50 64 38 57 60 59 55 47 43 43 DVSI LwA Surrounding DVSI 64 37 57 59 Measurement point: 0.70 m³/s @ 320 Pa 59 55 49 43 42 LwA Surrounding Measurement point: 0.61 m³/s @ 314 Pa Roof Fans | Q [m³/h] 1000 Q [m³/h] 1500 2000 2500 600 DHS/DVS/DVSI sileo 400E6 0 1000 2000 3000 4000 5000 DHS/DVS/DVSI sileo 450DV 13008 500 13147 250 0 6 500 200 Ps [Pa] Roof fans Ps [Pa] 400 150 300 100 200 50 100 0 200 2 3 4 5 800 5 P [W] P [W] 1 0 100 5 400 2 2 0 0 dB(A) Tot Frequency bands [Hz] dB(A) 63 125 250 500 1k 2k 4k 8k Tot Frequency bands [Hz] 250 500 1k 2k 4k 8k LwA Inlet 56 36 50 50 52 45 41 39 28 LwA Inlet 66 40 57 60 61 57 55 52 52 LwA Surrounding 60 44 53 54 54 51 46 43 33 LwA Surrounding 70 40 55 62 66 64 59 54 51 64 42 57 59 59 56 49 44 44 DVSI 63 125 DVSI 56 35 50 50 53 43 38 42 25 Measurement point: 0.42 m³/s @ 141 Pa LwA Surrounding Measurement point: 0.91 m³/s @ 372 Pa Q [m³/h] Q [m³/h] 1000 2000 3000 4000 5000 250 400 200 300 100 100 50 1 2 3 5 4 3000 4000 2 3 4 5 400 5 400 P [W] P [W] 2000 1 0 800 2 5 200 2 0 0 dB(A) 1000 150 200 0 0 DHS/DVS/DVSI sileo 450E6 500 Ps [Pa] Ps [Pa] DHS/DVS/DVSI sileo 450E4 300 13057 600 0 13058 LwA Surrounding Tot Frequency bands [Hz] dB(A) 63 125 250 500 1k 2k 4k 8k Tot Frequency bands [Hz] 250 500 1k 2k 4k 8k LwA Inlet 69 42 56 64 63 60 58 56 53 LwA Inlet 57 37 45 53 53 48 46 44 35 LwA Surrounding 72 47 58 67 67 66 61 55 50 LwA Surrounding 62 38 49 58 59 54 49 44 33 66 46 58 61 60 58 50 45 40 58 31 46 53 52 45 38 38 26 DVSI LwA Surrounding 63 125 DVSI Measurement point: 0.81 m³/s @ 361 Pa LwA Surrounding Measurement point: 0.63 m³/s @ 177 Pa | Roof Fans 400 0 1000 4000 5000 DHS/DVS/DVSI sileo 500DS 350 DHS/DVS/DVSI sileo 500DV Q [m³/h] 3000 2000 13074 7 Roof fans Ps [Pa] 300 250 200 150 100 50 1 0 2 3 4 5 P [W] 500 5 250 2 0 dB(A) Tot Frequency bands [Hz] dB(A) 63 125 250 500 1k 2k 4k 8k Tot Frequency bands [Hz] 250 500 1k 2k 4k 8k LwA Inlet 76 47 62 73 69 66 62 59 57 LwA Inlet 62 46 55 57 56 51 49 46 38 LwA Surrounding 77 47 65 68 73 71 67 62 57 LwA Surrounding 64 41 50 60 59 56 52 48 40 61 44 51 58 54 52 43 38 34 DVSI 63 125 DVSI 73 52 64 67 67 65 61 58 57 LwA Surrounding Measurement point: 0.84 m³/s @ 207 Pa Q [m³/h] 1000 2000 3000 Q [m³/h] 4000 5000 DHS/DVS/DVSI sileo 500E6 350 1000 13224 400 0 2500 5000 7500 10000 12500 DHS/DVS/DVSI sileo 560DV 800 300 250 600 Ps [Pa] Ps [Pa] 0 13069 LwA Surrounding Measurement point: 1.25 m³/s @ 449 Pa 200 400 150 100 200 50 1 0 2 3 4 5 1 0 2 3 4 5 P [W] P [W] 400 200 5 1000 2 0 dB(A) 2000 Tot 5 0 Frequency bands [Hz] 63 125 250 500 1k 2k 2 dB(A) 4k 8k Tot Frequency bands [Hz] 63 125 250 500 1k 2k 4k 8k LwA Inlet 63 42 55 58 58 51 49 45 38 LwA Inlet 73 44 62 66 68 67 64 59 52 LwA Surrounding 62 41 48 57 58 55 50 44 37 LwA Surrounding 75 46 64 68 70 69 66 61 54 66 59 59 61 59 53 46 44 38 DVSI LwA Surrounding DVSI 58 42 50 54 Measurement point: 0.84 m³/s @ 236 Pa 52 48 41 36 30 LwA Surrounding Measurement point: 1.89 m³/s @ 570 Pa Roof Fans | 4000 6000 8000 DHS/DVS/DVSI sileo 560DS 400 1200 13067 450 2000 0 2500 Q [m³/h] 7500 10000 12500 15000 17500 5000 DHS/DVS/DVSI sileo 630DV 10817 Q [m³/h] 0 8 1000 350 800 Ps [Pa] 250 200 Roof fans Ps [Pa] 300 600 400 150 100 200 50 1 0 2 3 4 5 3 4 5 5 600 400 P [W] P [W] 2 1500 800 1000 500 2 200 2 0 0 dB(A) 1 0 Tot Frequency bands [Hz] dB(A) 63 125 250 500 1k 2k 4k 8k Tot 5 Frequency bands [Hz] 250 500 1k 2k 4k 8k LwA Inlet 63 34 52 56 58 57 54 49 42 LwA Inlet 83 54 72 76 78 77 74 69 62 LwA Surrounding 65 36 54 58 60 59 56 51 44 LwA Surrounding 85 56 74 78 80 79 76 71 64 76 69 69 71 69 63 56 54 48 DVSI LwA Surrounding 56 49 49 52 49 44 36 34 27 Tot Frequency bands [Hz] 63 125 250 500 1k 2k 4k 8k LwA Inlet 67 38 56 60 62 61 58 53 46 LwA Surrounding 69 40 58 62 64 63 60 55 48 60 31 49 53 55 54 51 46 39 DVSI Measurement point: 1.74 m³/s @ 268 Pa LwA Surrounding Measurement point: 2.2 m³/s @ 788 Pa DVS sileo 630DS LwA Surrounding 125 DVSI Measurement point: 1.27 m³/s @ 243 Pa dB(A) 63
© Copyright 2025