FOCALPOINT HP PERFORMANCE SPECIFICATION: FOCALPOINT HP CONSTRUCTION GUIDE HIGH PERFORMANCE MEDIA A HIGH PERFORMANCE MEDIA MUST MEET A MINIMUM OF 100” PER HOUR INFILTRATION RATE. FIELD HYDRAULIC CONDUCTIVITY TESTING MUST BE CONDUCTED WITHIN 90 DAYS OF INSTALLATION. FIELD TEST MUST BE CONDUCTED WITH PROSCRIBED INFILTROMETER AND SOP (SEE SPECIFICATION). FAILURE TO MEET FIELD TESTING WILL RESULT IN THE REMOVAL OF MEDIA AND REPLACEMENT FROM ALTERNATE BATCH. B # UNDERDRAIN LONG C FOCALPOINT WIDTH D # UNDERDRAIN WIDE HIGH PERFORMANCE STRUCTURAL UNDERDRAIN E WATER QUALITY VOLUME MUST HAVE A MINIMUM OF 19 SQUARE INCHES OF ORIFICE OPENING PER SQUARE FOOT. MUST MEET H20 LOADING REQUIREMENTS. MUST BE MODULAR IN NATURE AND ASSEMBLED ON SITE. MUST HAVE MINIMUM 90% INTERIOR VOID SPACE. F OVERFLOW ELEVATION G OUTLET FLOWLINE H TOP OF MEDIA I TOP OF GABION (OPTIONAL) y OBSERVATION/ MAINTENANCE PORT C D x x y OVERFLOW DRAIN LANDSCAPE DISSIPATER/ BUFFER (WIDTH VARIES) SECTION Y-Y OVERFLOW DRAIN ELEV. _______(F) 3:1 SLOPE (max.) 12" OUTLET FLOWLINE ELEV. _______ (G) 6" OUTLET PIPE TOP OF MEDIA ELEV. _______(H) 12" STRUCTURAL UNDERDRAIN WWW.CONVERGENTWATER.COM/STORMWATER-PRODUCTS OR CONTACT STRUCTURAL UNDERDRAIN CONVERGENT WATER TECHNOLOGIES AT 800.771.5428 A B TO FIND A VALUE ADDED RESELLER IN YOUR AREA VISIT PLAN VIEW FOCALPOINT HP CONSTRUCTION GUIDE FOCALPOINT LENGTH 6" BRIDGING STONE (SEE SPECIFICATIONS) STRUCTURAL UNDERDRAIN (DEPTH VARIES) 3" COMPACTED BASE (MIN.) GEOTEXTILE WWW.CONVERGENTWATER.COM/STORMWATER-PRODUCTS OR CONTACT FP100 MICRO-GRID CONVERGENT WATER TECHNOLOGIES AT 800.771.5428 IMPERMEABLE LINER (OPTIONAL) TO FIND A VALUE ADDED RESELLER IN YOUR AREA VISIT 18" HIGH FLOW MEDIA 100"/ HR (MIN.) (SEE SPECIFICATIONS) FOCALPOINT HP DETAILED CROSS SECTION 3" SHREDDED HARDWOOD BARKMULCH (WITH FINES REMOVED) HIGH FLOW MEDIA BRIDGING STONE TO STORM SEWER SEE PIPE BOOT DETAIL FP100 MICRO-GRID STRUCTURAL UNDERDRAIN 3" COMPACTED BASE (MIN) WWW.CONVERGENTWATER.COM/STORMWATER-PRODUCTS OR CONTACT OBSERVATION/ MAINTENANCE PORT WITH FOCALPOINT INSPECTION PORT CAP CONVERGENT WATER TECHNOLOGIES AT 800.771.5428 SHREDDED HARDWOOD BARKMULCH (WITH FINES REMOVED) TO FIND A VALUE ADDED RESELLER IN YOUR AREA VISIT GEOTEXTILE FOCALPOINT HP SECTION X-X OVERFLOW DRAIN WITH SLANTED OR BEEHIVE GRATE (TYPE AND PLACEMENT VARIES) - RECOMMEND FABCO BEEHIVE OVERFLOW FILTER STRUCTURE OBSERVATION/ MAINTENANCE PORT CONNECTION PIPE BOOT DETAIL OUTLET PIPE STRUCTURAL UNDERDRAIN FRONT VIEW OUTLET/ INLET PIPE CONNECTION 2' OPEN MESH MICRO-GRID STAINLESS STEEL HOSE CLAMP PIPE O.D. PIPE BOOT STRUCTURAL UNDERDRAIN STAINLESS STEEL HOSE CLAMP SIDE VIEW TO FIND A VALUE ADDED RESELLER IN YOUR AREA VISIT FP100 OPEN MESH MICRO-GRID FOCALPOINT PIPE CONNECTION 3' WWW.CONVERGENTWATER.COM/STORMWATER-PRODUCTS OR CONTACT PIPE BOOT CONVERGENT WATER TECHNOLOGIES AT 800.771.5428 PIPE BOOT 3' OBSERVATION/ MAINTENANCE PORT MICRO-GRID PIPE BOOT 9" 4" NOTCH PATTERN AT BOTTOM OF PIPE (SEE NOTCH PATTERN DETAIL) PIPE NOTCH PATTERN DETAIL 4"-9" CUT IN SHADED AREAS WWW.CONVERGENTWATER.COM/STORMWATER-PRODUCTS OR CONTACT STAINLESS STEEL CLAMP 27" TYP. CONVERGENT WATER TECHNOLOGIES AT 800.771.5428 6" PVC MAINTENANCE PORT TO FIND A VALUE ADDED RESELLER IN YOUR AREA VISIT OBSERVATION/ MAINTENANCE PORT WITH FOCALPOINT INSPECTION PORT CAP FOCALPOINT OBSERVATION/ MAINTENANCE PORT PORT USED FOR INSPECTION PURPOSES AND FOR SYSTEM MAINTENANCE AS REQUIRED. WATER SHALL BE PUMPED INTO THE SYSTEM AND RESUSPEND ACCUMULATED SEDIMENT. MINIMUM REQUIRED MAINTENANCE INCLUDES A QUARTERLY INSPECTION FOR THE FIRST YEAR OF OPERATION AND A YEARLY INSPECTION THEREAFTER FLUSH AS NEEDED. B)SUPPORT HUB: CRS, POWDER COATED C)STORMSACK: WOVEN POLYPROPYLENE GEOTEXTILE (GEOTEXT 117) D)HARDWARE: ALUMINUM POP-RIVETS FILTERED FLOWRATE BYPASS FLOWRATE (CFS) (CFS) 12 0.77 2.2 1.2 18 1.65 2.5 1.0 24 3.60 4.9 2.4 30 6.20 4.9 2.4 3.RECOMMENDED MINIMUM VAULT DEPTH: 2-IN BELOW CARTRIDGE 4.TYPICAL INSTALLATION: RAISE STORM GRATE, PUSH CATCH-IT SHROUD DOWN ON FRAME SUPPORT LEDGE UNTIL LOCKING-CLIPS CLICK IN PLACE, LOWER STORM GRATE. 5.USE ONLY WITH FABCO REPLACEABLE STORMSACK. HARCO DRAIN INLET B STRUCTURE (REF) A DOME GRATE (REF) A SUPPORT RING FABCO CATCH-IT P/N: 9786-1-000 ADJUSTABLE B EXPANDABLE TURNBUCKLE SUPPORT RING P/N: 9786-1TR SEE DETAIL 2 ADJUSTABLE TURNBUCKLE SUPPORT RING CUTAWAY 1 (CATCH-IT REMOVED FOR CLARITY) HARCO DRAIN INLET SECTION B-B STRUCTURE (REF) (VIEW ROTATED 90~) (CATCH-IT REMOVED FOR CLARITY) SUPPORT RING SEE DETAIL #1 ADJUSTABLE PROTECTED BYPASS TURNBUCKLE DETAIL 2 REPLACMENT STORMSACK PROTECTED BYPASS Q Bypass REFERENCE VIEW SECTION A-A DETAIL 1 WWW.CONVERGENTWATER.COM/STORMWATER-PRODUCTS OR CONTACT A)SHROUD: HIGH DENSITY POLYETHYLENE (TYPICAL WALL THICKNESS .125") DEBRIS CAPACITY (CF) CONVERGENT WATER TECHNOLOGIES AT 800.771.5428 (INCHES) TO FIND A VALUE ADDED RESELLER IN YOUR AREA VISIT STRUCTURE DIAMETER 2.MATERIAL: FABCO BEEHIVE OVERFLOW FILTER STRUCTURE DETAILS NOTES: 1.WEIGHT (EMPTY): 12 LB MAX
© Copyright 2024