#TJ-9505 SPECIFIER’S GUIDE HEADERS, BEAMS, AND COLUMNS Featuring Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL • Uniform and Predictable • Minimal Bowing, Twisting, and Shrinking • Strong and Straight • Limited Product Warranty Woodbywy.com 1.888.453.8358 WESTERN CANADA Why Choose Trus Joist® Beams, Columns, and Headers? •Reliable performance •Consistent quality and dependable uniformity •Flexible solutions for your beam and header needs •Backed by a limited product warranty Using advanced technology, Weyerhaeuser manufactures engineered lumber that is consistently straight and strong, and that resists bowing, twisting, and shrinking. That means less waste, easier installation, and higher design values for starters; plus fewer callbacks, shorter cycle times, more design flexibility, and lower overall installed cost in the end. Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL are structural solutions you can count on—guaranteed. This guide features Trus Joist® engineered lumber in the following widths and depths: TimberStrand® LSL The products in this guide are readily available through our n ationwide network of distributors and dealers. For more information on other applications or other Trus Joist products, contact your Weyerhaeuser representative. TABLE OF CONTENTS General Assumptions 3 Design Properties 4 Floor and/or Snow Load Tables TimberStrand® LSL 5 Microllam® LVL 6–7 Parallam® PSL 8–9 Beam Details 10 Window and Door Header Details 10–11 Nailing on Narrow Face 11 Allowable Holes 12 Bearing Length Requirements 12 Tapered End Cuts 13 Multiple-Member Connections 14–16 Header Design Example Problem 16 Parallam® PSL Columns 17 Product Warranty 20 1.55E TimberStrand® LSL header and beam sizes: Widths: 1¾" and 3½" Depths: 9½", 117⁄8", 14", and 16" Microllam® LVL 2.0E Microllam® LVL header and beam sizes: Width: 1¾" Depths: 5 ½", 7¼", 9¼", 9½", 11¼", 117⁄8", 14", 16", 18¾", and 20" Parallam® PSL 2.0E Parallam® PSL header and beam sizes: Widths: 1¾", 3½", 5¼", and 7" Depths: 9¼", 9½", 11¼", 117⁄8", 14", 16", and 19" 1.8E Parallam® PSL column and post sizes: 31⁄2" x 31⁄2" 31⁄2" x 51⁄4" 31⁄2" x 7" 51⁄4" x 51⁄4" 51⁄4" x 7" 7" x 7" For deeper depth Parallam® PSL beams, see the Trus Joist® 2.2E Parallam® PSL Deep Beam Technical Resource Sheet, #TJ-7501, or contact your Weyerhaeuser representative. Grades shown are available in Western Canada; some sizes may not be available in your region. Product Storage Protect product from sun and water CAUTION: Wrap is slippery when wet or icy ® Align 2x3 (or larger) stickers directly over support blocks ® ® ® Use 6x6 (or larger) support blocks at 10' on-centre to keep bundles out of mud and water Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 2 TJ-9505 | June 2014 Structural Solutions Trus Joist® TimberStrand® Laminated Strand Lumber (LSL) •One-piece members reduce labor time •Every piece is straight and strong •Unique properties allow you to drill larger holes through 1.55E TimberStrand® LSL. See Allowable Holes on page 12. Code Evaluations: See CCMC 12627-R Trus Joist® Microllam® Laminated Veneer Lumber (LVL) • Can easily be built up on site to reduce heavy lifting •Offers reliable and economical solutions for beam and header applications •Manufacturing process minimizes many of the natural inconsistencies found in wood Code Evaluations: See CCMC O8675-R Trus Joist® Parallam® Parallel Strand Lumber (PSL) •Allows long spans for open floor plans without intermediate posts or columns • Has warm, unique grain that is perfect for applications with exposed beams • Provides ideal solutions for cantilever and multi-span applications • Solid sections save time on site assembly Code Evaluations: See CCMC 11161-R General Assumptions for Products Shown in this Guide •Specified strengths and factored resistances are based on Limit States Design per CSA O86. •Beams that are 1¾" x 16" and deeper require multiple plies. •No camber. •Lateral support is required at bearing and along the span at 24" on-centre, maximum. •Beams and columns must remain straight to within 5L2⁄4608 (in.) of true alignment. L is the unrestrained length of the member in feet. •Bearing lengths are based on each product’s bearing resistance for applicable grade and orientation. For applications not covered in this guide, contact your Weyerhaeuser representative. •All members 7¼" and less in depth are restricted to a maximum deflection of 5⁄16". See pages 14–16 for multiple-member beam connections. TimberStrand® LSL, Microllam® LVL, and untreated Parallam® PSL are intended for dry-use applications Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 3 TJ-9505 | June 2014 dESIGN PROPERTIES Factored Resistances(1) (Standard Term) Grade Width Design Property Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) 1¾" 1.55E 3½" 2.0E 5½" Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) 1¾" 3,535 3,060 24 2.8 7¼" 9¼" 9½" TimberStrand ® LSL 8,665 5,735 125 5.2 17,325 11,470 250 10.4 Microllam ® LVL 5,915 4,035 56 3.7 9,315 5,150 115 4.7 11¼" Depth 117⁄8" 14" 16" 13,260 7,170 244 6.5 26,525 14,340 488 13.0 18,155 8,455 400 7.7 36,310 16,905 800 15.3 23,425 9,660 597 8.8 46,850 19,320 1,195 17.5 18¾" 9,790 5,285 125 4.8 13,420 14,845 20,175 25,875 34,775 6,260 6,610 7,790 8,905 10,435 208 244 400 597 961 5.7 6.1 7.1 8.2 9.6 10,860 5,385 125 5.2 21,720 10,775 250 10.4 32,580 16,160 375 15.6 43,440 21,545 500 20.8 14,945 6,380 208 6.2 29,890 12,760 415 12.3 44,840 19,135 623 18.5 59,785 25,515 831 24.6 19" 20" 39,220 11,130 1,167 10.2 Beam Orientation Column Orientation Parallam ® PSL Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) Factored Moment Resistance (ft-lbs) Factored Shear Resistance (lbs) Moment of Inertia (in. 4) Weight (plf) 1¾" 3½" 2.2E 5¼" 7" 10,325 5,245 115 5.1 20,655 10,490 231 10.1 30,980 15,735 346 15.2 41,305 20,980 462 20.2 16,555 6,735 244 6.5 33,105 13,465 488 13.0 49,660 20,200 733 19.5 66,215 26,935 977 26.0 22,590 7,940 400 7.7 45,180 15,875 800 15.3 67,775 23,815 1,201 23.0 90,365 31,750 1,601 30.6 29,075 9,070 597 8.8 58,145 18,145 1,195 17.5 87,220 27,215 1,792 26.3 116,290 36,290 2,389 35.0 40,220 10,775 1,000 10.4 80,445 21,545 2,001 20.8 120,665 32,320 3,001 31.2 160,890 43,090 4,001 41.6 Plank Orientation (1) For product in beam orientation, unless otherwise noted. Specified Strengths(1) and Moduli of Elasticity (Standard Term) Grade G Modulus Orientation Shear of Elasticity (psi) E Modulus of Elasticity (psi) fb Flexural Stress (2) (psi) 1.55E Beam 96,875 1.55 x 106 4,295 2.0E Beam 125,000 2.0 x 106 4,805 1.8E 2.2E Column Beam 112,500 137,500 1.8 x 106 2.2 x 106 4,435(8) 5,360 ft Tension Stress (3) (psi) TimberStrand ® LSL 1,975(7) Microllam ® LVL 2,870 Parallam ® PSL 3,245 3,750 (1) To obtain factored resistances, apply the appropriate formulae from CSA O86 to the specified strengths shown. (2) For 12" depth. For other depths, multiply fb by the appropriate factor as follows: – For – For Parallam® fcll Compression Parallel to Grain (psi) fv Horizontal Shear Parallel to Grain (psi) SG Equivalent Specific Gravity (5) 1,455 3,270 575(7) 0.50(6) 1,365 4,005 530 0.50 775(8) 1,365 3,990 4,630(9) 355(8) 540 0.50 0.50 (3) ft has been adjusted to reflect the volume effects for most standard applications. (4) fc⊥ must not be increased for duration of load. (5) For lateral connection design only. (6) Specific gravity of 0.58 may be used for bolts installed perpendicular to face and loaded perpendicular to grain. (7) Value accounts for large hole capabilities. See Allowable Holes on page 12. (8) Value shown is for plank orientation. (9) For column applications, use a specified strength of 800 psi. [] LVL, multiply by [ ] PSL, multiply by [ ] 12 0.092 d 12 0.136 d 12 0.111 d – For TimberStrand® LSL, multiply by Microllam® fc⊥ Compression Perpendicular to Grain (4) (psi) TimberStrand® LSL, Microllam® LVL, and untreated Parallam® PSL are intended for dry-use applications Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 4 TJ-9505 | June 2014 Floor and/or snow Load Tables How to Use This Table General Notes 1.Calculate the factored and unfactored total load (TL) (neglect beam weight) and the unfactored live load (LL) on the beam or header in pounds per linear foot (plf). Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/360 live load (LL) and L/240 total load (TL). For a live load deflection limit of L/480, multiply Unfactored Resistance (LL) by 0.75. For a total load limit of L /180 multiply Unfactored Resistance (TL) by 1.33. The resulting loads must not exceed the Total Factored Resistance shown. ■ 2.Select appropriate Span (centre-to-centre of bearing). ■ 3.Scan horizontally to find the proper width and a depth that has a capacity that meets or exceeds actual loads. 4.Review bearing length requirements to ensure adequacy. Also General Assumptions on page 3. 1.55E TimberStrand® LSL: Floor and /or Snow—Standard Term (PLF) Span 4' 5' 6' 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' Condition Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) 9½" * * 3,351 3.3/8.2 1,658 * 2,452 3.0/7.5 1,049 * 1,919 2.8/7.1 487 726 1,076 2.1/5.3 303 449 761 1.8/4.5 262 388 687 1.7/4.3 156 228 475 1.5/3.5 100 144 347 1.5/3.5 62 87 248 1.5/3.5 44 61 196 1.5/3.5 1¾" Width 117⁄8" * * 4,574 4.5/11.3 * * 3,349 4.1/10.3 * * 2,589 3.8/9.6 887 * 1,650 3.3/8.1 561 * 1,167 2.7/6.9 487 725 1,053 2.6/6.5 294 434 729 2.2/5.4 190 278 533 1.9/4.7 118 171 382 1.6/3.9 85 121 302 1.5/3.5 68 95 257 1.5/3.5 14" * * 4,574 4.5/11.3 * * 3,657 4.5/11.3 * * 3,046 4.5/11.3 1,353 * 2,195 4.3/10.8 870 * 1,600 3.8/9.4 760 * 1,443 3.6/9.0 464 689 999 3.0/7.5 303 446 731 2.6/6.4 190 277 524 2.2/5.4 137 198 415 1.9/4.8 109 156 354 1.8/4.5 9½" * * 6,702 3.3/8.2 3,317 * 4,903 3.0/7.5 2,098 * 3,837 2.8/7.1 975 1,452 2,153 2.1/5.3 605 897 1,523 1.8/4.5 524 775 1,373 1.7/4.3 311 457 950 1.5/3.5 199 289 694 1.5/3.5 123 175 496 1.5/3.5 88 122 392 1.5/3.5 70 95 334 1.5/3.5 3½" Width 117⁄8" 14" * * * * 9,145 9,145 4.5/11.3 4.5/11.3 * * * * 6,699 7,311 4.1/10.3 4.5/11.3 * * * * 5,178 6,089 3.8/9.6 4.5/11.3 1,774 2,706 * * 3,299 4,391 3.3/8.1 4.3/10.8 1,121 1,740 * * 2,335 3,200 2.7/6.9 3.8/9.4 975 1,520 1,449 * 2,106 2,886 2.6/6.5 3.6/8.9 588 929 868 1,378 1,457 1,998 2.2/5.4 3.0/7.4 380 605 556 892 1,066 1,463 1.9/4.7 2.5/6.4 237 380 342 555 763 1,048 1.6/3.9 2.2/5.4 170 274 242 395 604 830 1.5/3.5 1.9/4.8 135 218 190 312 514 707 1.5/3.5 1.8/4.5 16" * * 9,145 4.5/11.3 * * 7,311 4.5/11.3 * * 6,089 4.5/11.3 * * 4,561 4.5/11.3 2,456 * 3,838 4.5/11.3 2,155 * 3,645 4.5/11.3 1,335 * 2,581 3.9/9.6 877 1,299 1,890 3.3/8.3 555 815 1,355 2.8/7.0 401 584 1,073 2.5/6.3 321 464 915 2.3/5.8 9½" * * 10,053 3.3/8.2 4,975 * 7,355 3.0/7.5 3,146 * 5,756 2.8/7.1 1,462 2,178 3,229 2.1/5.3 908 1,346 2,284 1.8/4.5 786 1,163 2,060 1.7/4.3 467 685 1,424 1.5/3.5 299 433 1,041 1.5/3.5 185 262 744 1.5/3.5 132 183 588 1.5/3.5 105 142 500 1.5/3.5 5¼" Width (2- or 3-ply) 117⁄8" 14" 16" * * * * * * 13,717 13,717 13,717 4.5/11.3 4.5/11.3 4.5/11.3 * * * * * * 10,048 10,967 10,967 4.1/10.3 4.5/11.3 4.5/11.3 * * * * * * 7,767 9,134 9,134 3.8/9.6 4.5/11.3 4.5/11.3 2,660 4,058 * * * * 4,949 6,586 6,842 3.3/8.1 4.3/10.8 4.5/11.3 1,682 2,611 3,685 * * * 3,502 4,799 5,757 2.7/6.9 3.8/9.4 4.5/11.3 1,462 2,280 3,232 2,174 * * 3,158 4,329 5,467 2.6/6.5 3.6/8.9 4.5/11.3 881 1,393 2,002 1,303 2,067 * 2,186 2,997 3,871 2.2/5.4 3.0/7.4 3.9/9.6 569 908 1,316 835 1,339 1,948 1,600 2,194 2,835 1.9/4.7 2.5/6.4 3.3/8.3 355 570 833 513 832 1,223 1,145 1,572 2,032 1.6/3.9 2.2/5.4 2.8/7.0 255 410 602 362 593 877 906 1,244 1,610 1.5/3.5 1.9/4.8 2.5/6.3 203 327 481 285 468 696 771 1,061 1,373 1.5/3.5 1.8/4.5 2.3/5.8 * Indicates Total Factored Resistance value controls. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 5 TJ-9505 | June 2014 Floor and/or snow Load Tables How to Use This Table 1.Calculate the factored and unfactored total load (TL) (neglect beam weight) and the unfactored live load (LL) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (centre-to-centre of bearing). 3.Scan horizontally to find the proper width and a depth that has a capacity that meets or exceeds actual loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 7. 2.0E Microllam® LVL: Floor and /or Snow—Standard Term (PLF) Span Condition Unfactored Resistance (LL) Unfactored Resistance (TL) 6' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 8' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 9'-6" Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 10' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 12' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 14' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 16'-6" Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 18'-6" Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 20' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 24' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 28' Total Factored Resistance Min. End/Int. Bearing (in.) 5½" 305 455 782 1.5/3.5 134 154 438 1.5/3.5 80 77 310 1.5/3.5 65 62 279 1.5/3.5 32 29 193 1.5/3.5 7¼" 660 * 1,278 2/5 296 343 735 1.5/3.9 178 175 520 1.5/3.5 146 142 469 1.5/3.5 72 68 324 1.5/3.5 39 35 237 1.5/3.5 9¼" * * 1,722 2.7/6.8 585 * 1,159 2.4/6.1 362 539 820 2.1/5.1 313 465 739 2/4.9 186 274 512 1.6/4.1 119 174 374 1.5/3.5 74 106 268 1.5/3.5 53 74 212 1.5/3.5 42 58 180 1.5/3.5 1¾" Width 9½" * * 1,781 2.8/7 629 * 1,218 2.6/6.4 390 581 862 2.2/5.4 338 502 777 2/5.1 201 297 538 1.7/4.3 129 188 394 1.5/3.7 80 115 282 1.5/3.5 57 81 223 1.5/3.5 45 63 190 1.5/3.5 11¼" * * 2,219 3.5/8.7 992 * 1,534 3.2/8.1 624 * 1,182 3/7.4 542 * 1,066 2.8/7 326 483 738 2.3/5.9 210 309 541 2/5 130 190 387 1.7/4.3 93 134 307 1.5/3.8 74 106 261 1.5/3.5 43 59 179 1.5/3.5 117⁄8" 14" 5½" 611 * * 911 * * 2,386 2,859 1,564 3.8/9.4 4.5/11.3 1.5/3.5 * 267 * 308 * * 1,640 2,024 877 3.4/8.6 4.3/10.6 1.5/3.5 723 * 160 154 * * 1,308 1,624 620 3.3/8.2 4.1/10.1 1.5/3.5 629 981 131 125 * * 1,180 1,524 559 3.1/7.8 4/10 1.5/3.5 379 599 64 563 58 * 817 1,112 386 2.6/6.5 3.5/8.8 1.5/3.5 245 390 35 361 * 29 598 814 282 2.2/5.5 3/7.5 1.5/3.5 153 245 18 223 361 12 429 584 201 1.9/4.7 2.6/6.4 1.5/3.5 109 176 158 258 339 463 1.7/4.2 2.3/5.7 87 141 125 204 289 395 1.6/3.9 2.1/5.3 51 83 70 117 199 271 1.5/3.5 1.8/4.4 53 72 197 1.5/3.8 7¼" 1,319 * 2,556 2/5 591 686 1,470 1.5/3.9 357 349 1,040 1.5/3.5 292 285 937 1.5/3.5 143 136 648 1.5/3.5 78 71 474 1.5/3.5 41 33 338 1.5/3.5 26 19 267 1.5/3.5 19 12 227 1.5/3.5 3½" Width (2-ply) 9¼" 9½" 11¼" * * * * * * 3,444 3,562 4,438 2.7/6.8 2.8/7 3.5/8.7 1,169 1,258 1,985 * * * 2,318 2,436 3,068 2.4/6.1 2.6/6.4 3.2/8.1 724 781 1248 1,077 1,162 * 1,640 1,724 2,365 2.1/5.1 2.2/5.4 3/7.4 627 676 1,084 931 1,004 * 1,479 1,555 2,133 2/4.9 2/5.1 2.8/7 372 402 651 549 593 965 1,023 1,076 1,477 1.6/4.1 1.7/4.3 2.3/5.9 238 257 420 348 376 618 749 787 1,081 1.5/3.5 1.5/3.7 2/5 147 159 261 212 229 380 536 563 774 1.5/3.5 1.5/3.5 1.7/4.3 105 114 187 148 161 269 424 446 613 1.5/3.5 1.5/3.5 1.5/3.8 84 90 149 116 126 212 361 380 522 1.5/3.5 1.5/3.5 1.5/3.5 49 53 87 64 69 119 247 260 358 1.5/3.5 1.5/3.5 1.5/3.5 31 33 55 37 40 71 178 188 260 1.5/3.5 1.5/3.5 1.5/3.5 * Indicates Total Factored Resistance value controls. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 6 TJ-9505 | June 2014 117⁄8" 14" * * * * 4,773 5,713 3.8/9.4 4.5/11.3 * * * * 3,280 4,047 3.4/8.6 4.3/10.6 1,447 * * * 2,616 3,248 3.3/8.2 4.1/10.1 1,258 1,961 * * 2,360 3,047 3.1/7.8 4/10 758 1,198 1,125 * 1,634 2,224 2.6/6.5 3.5/8.8 490 781 723 * 1,197 1,629 2.2/5.5 3/7.5 305 490 446 721 857 1,168 1.9/4.7 2.6/6.4 219 353 316 515 679 925 1.7/4.2 2.3/5.7 174 282 249 408 579 789 1.6/3.9 2.1/5.3 102 166 141 234 397 543 1.5/3.5 1.8/4.4 65 105 85 144 288 394 1.5/3.5 1.5/3.8 Floor and/or snow Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. – Deflection criteria of L/360 live load (LL) and L/240 total load (TL). For a live load deflection limit of L/480, multiply Unfactored Resistance (LL) by 0.75. For a total load limit of L /180 multiply Unfactored Resistance (TL) by 1.33. The resulting loads must not exceed the Total Factored Resistance shown. Also see How to Use This Table on page 6 and General Assumptions on page 3. 2.0E Microllam® LVL: Floor and /or Snow—Standard Term (PLF) continued 3½" Width (2-ply) 16" 18¾" 20" Unfactored Resistance (LL) * * * Unfactored Resistance (TL) * * * 6' Total Factored Resistance 5,713 5,713 5,713 Min. End/Int. Bearing (in.) 4.5/11.3 4.5/11.3 4.5/11.3 Unfactored Resistance (LL) * * * Unfactored Resistance (TL) * * * 8' Total Factored Resistance 4,279 4,279 4,279 Min. End/Int. Bearing (in.) 4.5/11.3 4.5/11.3 4.5/11.3 Unfactored Resistance (LL) * * * Unfactored Resistance (TL) * * * 9'-6" Total Factored Resistance 3,600 3,600 3,600 Min. End/Int. Bearing (in.) 4.5/11.3 4.5/11.3 4.5/11.3 Unfactored Resistance (LL) * * * Unfactored Resistance (TL) * * * 10' Total Factored Resistance 3,419 3,419 3,419 Min. End/Int. Bearing (in.) 4.5/11.3 4.5/11.3 4.5/11.3 Unfactored Resistance (LL) 1,722 * * Unfactored Resistance (TL) * * * 12' Total Factored Resistance 2,846 2,846 2,846 Min. End/Int. Bearing (in.) 4.5/11.3 4.5/11.3 4.5/11.3 Unfactored Resistance (LL) 1,132 * * Unfactored Resistance (TL) * * * 14' Total Factored Resistance 2,092 2,437 2,437 Min. End/Int. Bearing (in.) 3.9/9.7 4.5/11.3 4.5/11.3 Unfactored Resistance (LL) 716 1,115 1,331 Unfactored Resistance (TL) * * * 16'-6" Total Factored Resistance 1,500 2,020 2,064 Min. End/Int. Bearing (in.) 3.3/8.2 4.4/11 4.5/11.3 Unfactored Resistance (LL) 518 811 971 Unfactored Resistance (TL) 760 * * 18'-6" Total Factored Resistance 1,189 1,602 1,808 Min. End/Int. Bearing (in.) 2.9/7.3 3.9/9.8 4.4/11.1 Unfactored Resistance (LL) 414 651 781 Unfactored Resistance (TL) 605 * * 20' Total Factored Resistance 1,015 1,367 1,543 Min. End/Int. Bearing (in.) 2.7/6.8 3.6/9.1 4.1/10.3 Unfactored Resistance (LL) 244 387 466 Unfactored Resistance (TL) 350 561 678 24' Total Factored Resistance 698 942 1,064 Min. End/Int. Bearing (in.) 2.3/5.6 3/7.6 3.4/8.6 Unfactored Resistance (LL) 156 248 299 Unfactored Resistance (TL) 217 352 428 28' Total Factored Resistance 508 686 775 Min. End/Int. Bearing (in.) 1.9/4.8 2.6/6.5 2.9/7.3 Span Condition 5½" 916 1,366 2,346 1.5/3.5 401 462 1,315 1.5/3.5 240 231 930 1.5/3.5 196 187 838 1.5/3.5 95 87 579 1.5/3.5 52 43 422 1.5/3.5 27 19 301 1.5/3.5 17 9 237 1.5/3.5 13 4 202 1.5/3.5 7¼" 1,979 * 3,834 2/5 887 1,028 2,205 1.5/3.9 535 524 1,560 1.5/3.5 439 427 1,406 1.5/3.5 215 204 972 1.5/3.5 117 106 711 1.5/3.5 61 50 508 1.5/3.5 39 28 401 1.5/3.5 29 17 341 1.5/3.5 14 3 233 1.5/3.5 9¼" * * 5,166 2.7/6.8 1,754 * 3,476 2.4/6.1 1,087 1,616 2,460 2.1/5.1 940 1,396 2,218 2/4.9 558 823 1,535 1.6/4.1 357 522 1,123 1.5/3.5 221 317 804 1.5/3.5 158 223 636 1.5/3.5 125 174 541 1.5/3.5 73 95 371 1.5/3.5 46 55 268 1.5/3.5 9½" * * 5,343 2.8/7 1,887 * 3,654 2.6/6.4 1,171 1,742 2,586 2.2/5.4 1,014 1,506 2,332 2/5.1 603 890 1,614 1.7/4.3 386 565 1,181 1.5/3.7 239 344 845 1.5/3.5 171 242 668 1.5/3.5 136 189 569 1.5/3.5 79 104 390 1.5/3.5 50 60 282 1.5/3.5 5¼" Width (3-ply) 11¼" 117⁄8" 14" 16" 18¾" 20" * * * * * * * * * * * * 6,656 7,159 8,569 8,569 8,569 8,569 3.5/8.7 3.8/9.4 4.5/11.3 4.5/11.3 4.5/11.3 4.5/11.3 2,977 * * * * * * * * * * * 4,602 4,921 6,071 6,419 6,419 6,419 3.2/8.1 3.4/8.6 4.3/10.6 4.5/11.3 4.5/11.3 4.5/11.3 1,873 2,170 * * * * * * * * * * 3,547 3,924 4,872 5,401 5,401 5,401 3/7.4 3.3/8.2 4.1/10.1 4.5/11.3 4.5/11.3 4.5/11.3 1,626 1,887 2,942 * * * * * * * * * 3,199 3,540 4,571 5,129 5,129 5,129 2.8/7 3.1/7.8 4/10 4.5/11.3 4.5/11.3 4.5/11.3 977 1,137 1,798 2,583 * * 1,448 1,688 * * * * 2,215 2,451 3,336 4,269 4,269 4,269 2.3/5.9 2.6/6.5 3.5/8.8 4.5/11.3 4.5/11.3 4.5/11.3 629 735 1,171 1,698 * * 927 1,084 * * * * 1,622 1,795 2,443 3,138 3,655 3,655 2/5 2.2/5.5 3/7.5 3.9/9.7 4.5/11.3 4.5/11.3 391 458 735 1,074 1,672 1,996 570 669 1,082 * * * 1,162 1,286 1,752 2,250 3,030 3,096 1.7/4.3 1.9/4.7 2.6/6.4 3.3/8.2 4.4/11 4.5/11.3 280 328 529 777 1,216 1,456 403 474 773 1,140 * * 920 1,018 1,388 1,784 2,403 2,712 1.5/3.8 1.7/4.2 2.3/5.7 2.9/7.3 3.9/9.8 4.4/11.1 223 262 423 621 977 1,171 318 374 612 907 * * 784 868 1,184 1,522 2,051 2,315 1.5/3.5 1.6/3.9 2.1/5.3 2.7/6.8 3.6/9.1 4.1/10.3 130 153 248 367 580 698 178 211 351 526 842 1,017 538 596 814 1,048 1,413 1,596 1.5/3.5 1.5/3.5 1.8/4.4 2.3/5.6 3/7.6 3.4/8.6 83 97 158 234 371 448 107 127 215 326 529 641 389 432 591 761 1,029 1,162 1.5/3.5 1.5/3.5 1.5/3.8 1.9/4.8 2.6/6.5 2.9/7.3 * Indicates Total Factored Resistance value controls. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 7 TJ-9505 | June 2014 Floor and/or snow Load Tables How to Use This Table 1.Calculate the factored and unfactored total load (TL) (neglect beam weight) and the unfactored live load (LL) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (centre-to-centre of bearing). 3.Scan horizontally to find the proper width and a depth that has a capacity that meets or exceeds actual loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 9. 2.2E Parallam® PSL: Floor and /or Snow—Standard Term (PLF) Span Condition Unfactored Resistance (LL) Unfactored Resistance (TL) 8' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 9'-6" Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 10' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 12' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 14' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 16'-6" Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 18'-6" Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 20' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 24' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 28' Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) 32' Total Factored Resistance Min. End/Int. Bearing (in.) 91 ⁄4" 643 * 1,234 2.6/6.5 398 593 909 2.3/5.7 345 512 820 2.2/5.4 205 302 567 1.8/4.5 131 191 415 1.5/3.9 81 116 297 1.5/3.5 58 82 235 1.5/3.5 46 64 200 1.5/3.5 91 ⁄ 2 " 692 * 1,273 2.7/6.7 429 639 956 2.4/6 372 552 862 2.3/5.7 221 326 597 1.9/4.7 142 207 437 1.6/4.1 88 126 313 1.5/3.5 63 89 247 1.5/3.5 50 69 211 1.5/3.5 13/4" Width 111 ⁄4" * * 1,562 3.3/8.2 687 * 1,268 3.2/7.9 596 * 1,188 3.1/7.8 358 531 823 2.6/6.5 231 340 602 2.2/5.6 144 209 431 1.9/4.7 103 148 342 1.7/4.2 82 117 291 1.6/3.9 48 66 200 1.5/3.5 117⁄ 8" 14" 91 ⁄4" * * 1,286 * * * 1,671 2,061 2,468 3.5/8.8 4.3/10.8 2.6/6.5 796 * 797 * * 1,185 1,353 1,654 1,818 3.4/8.5 4.1/10.3 2.3/5.7 692 * 689 * * 1,024 1,272 1,552 1,640 3.3/8.4 4.1/10.2 2.2/5.4 417 659 409 619 * 604 912 1,244 1,135 2.9/7.2 3.9/9.8 1.8/4.5 269 429 262 398 * 383 668 913 830 2.5/6.2 3.4/8.4 1.5/3.9 168 270 162 245 397 233 478 654 594 2.1/5.2 2.9/7.2 1.5/3.5 120 194 116 174 284 163 379 518 470 1.9/4.7 2.6/6.4 1.5/3.5 96 155 92 137 225 128 323 442 400 1.7/4.3 2.4/5.9 1.5/3.5 56 91 54 78 129 70 222 304 274 1.5/3.6 2/4.9 1.5/3.5 58 34 79 41 221 198 1.7/4.2 1.5/3.5 91 ⁄ 2 " 1,384 * 2,547 2.7/6.7 859 1,278 1,912 2.4/6 743 1,105 1,725 2.3/5.7 442 653 1,194 1.9/4.7 283 414 874 1.6/4.1 175 252 625 1.5/3.5 125 177 495 1.5/3.5 99 139 421 1.5/3.5 58 77 289 1.5/3.5 37 45 209 1.5/3.5 111 ⁄4" * * 3,125 3.3/8.2 1,373 * 2,536 3.2/7.9 1,193 * 2,376 3.1/7.8 716 1,062 1,645 2.6/6.5 461 680 1,205 2.2/5.6 287 418 863 1.9/4.7 206 296 683 1.7/4.2 164 233 582 1.6/3.9 96 131 400 1.5/3.5 61 79 290 1.5/3.5 41 49 218 1.5/3.5 31 ⁄ 2" Width 117⁄ 8" 14" * * * * 3,342 4,122 3.5/8.8 4.3/10.8 1,591 * * * 2,705 3,309 3.4/8.5 4.1/10.3 1,384 * * * 2,544 3,104 3.3/8.4 4.1/10.2 834 1,318 1,238 * 1,823 2,488 2.9/7.2 3.9/9.8 539 859 795 * 1,335 1,825 2.5/6.2 3.4/8.4 336 539 491 794 957 1,309 2.1/5.2 2.9/7.2 241 388 348 567 758 1,037 1.9/4.7 2.6/6.4 192 310 275 449 646 885 1.7/4.3 2.4/5.9 112 182 155 258 444 608 1.5/3.6 2/4.9 71 116 94 158 322 442 1.5/3.5 1.7/4.2 48 78 59 102 242 334 1.5/3.5 1.5/3.7 16" * * 4,279 4.5/11.3 * * 3,600 4.5/11.3 * * 3,419 4.5/11.3 1,894 * 2,846 4.5/11.3 1,245 * 2,351 4.3/10.9 788 * 1,687 3.7/9.2 570 837 1,337 3.3/8.2 456 666 1,141 3/7.6 269 386 786 2.5/6.3 171 240 571 2.2/5.4 116 156 432 1.9/4.8 * Indicates Total Factored Resistance value controls. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 8 TJ-9505 | June 2014 19" * * 4,279 4.5/11.3 * * 3,600 4.5/11.3 * * 3,419 4.5/11.3 * * 2,846 4.5/11.3 * * 2,436 4.5/11.3 1,272 * 2,064 4.5/11.3 926 * 1,839 4.5/11.3 743 * 1,583 4.2/10.5 442 642 1,091 3.5/8.8 283 404 795 3/7.5 192 267 602 2.6/6.6 Floor and/or snow Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. – Deflection criteria of L/360 live load (LL) and L/240 total load (TL). For a live load deflection limit of L/480, multiply Unfactored Resistance (LL) by 0.75. For a total load limit of L/180 multiply Unfactored Resistance (TL) by 1.33. The resulting loads must not exceed the Total Factored Resistance shown. Also see How to Use This Table on page 8 and General Assumptions on page 3. 2.2E Parallam® PSL: Floor and /or Snow—Standard Term (PLF) continued Span 8' 9'-6" 10' 12' 14' 16'-6" 18'-6" 20' 24' 28' 32' Condition Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) 91 ⁄4" 1,929 * 3,701 2.6/6.5 1,195 1,778 2,727 2.3/5.7 1,034 1,536 2,459 2.2/5.4 614 906 1,702 1.8/4.5 393 574 1,245 1.5/3.9 243 349 891 1.5/3.5 174 245 705 1.5/3.5 138 192 601 1.5/3.5 80 105 411 1.5/3.5 51 61 297 1.5/3.5 34 36 223 1.5/3.5 91 ⁄ 2 " 2,076 * 3,820 2.7/6.7 1,288 1,917 2,868 2.4/6 1,115 1,657 2,587 2.3/5.7 663 979 1,790 1.9/4.7 425 621 1,310 1.6/4.1 263 379 938 1.5/3.5 188 266 742 1.5/3.5 149 208 632 1.5/3.5 87 115 433 1.5/3.5 55 67 313 1.5/3.5 37 40 235 1.5/3.5 111 ⁄4" * * 4,687 3.3/8.2 2,060 * 3,804 3.2/7.9 1,789 * 3,564 3.1/7.8 1,074 1,593 2,468 2.6/6.5 692 1,020 1,807 2.2/5.6 431 627 1,294 1.9/4.7 308 444 1,025 1.7/4.2 245 350 874 1.6/3.9 144 197 600 1.5/3.5 91 118 434 1.5/3.5 61 73 327 1.5/3.5 51/4" Width 117⁄ 8" * * 5,012 3.5/8.8 2,387 * 4,058 3.4/8.5 2,076 * 3,816 3.3/8.4 1,251 1,857 2,735 2.9/7.2 808 1,193 2,003 2.5/6.2 504 736 1,435 2.1/5.2 361 522 1,136 1.9/4.7 288 412 969 1.7/4.3 168 233 665 1.5/3.6 107 141 482 1.5/3.5 72 88 364 1.5/3.5 14" * * 6,184 4.3/10.8 * * 4,963 4.1/10.3 * * 4,656 4.1/10.2 1,977 * 3,731 3.9/9.8 1,288 * 2,738 3.4/8.4 809 1,190 1,963 2.9/7.2 582 851 1,555 2.6/6.4 465 674 1,327 2.4/5.9 273 387 913 2/4.9 174 237 663 1.7/4.2 117 153 501 1.5/3.7 16" * * 6,418 4.5/11.3 * * 5,400 4.5/11.3 * * 5,129 4.5/11.3 2,841 * 4,269 4.5/11.3 1,868 * 3,527 4.3/10.9 1,182 * 2,530 3.7/9.2 854 1,255 2,006 3.3/8.2 683 999 1,712 3/7.6 403 579 1,179 2.5/6.3 257 359 857 2.2/5.4 174 234 649 1.9/4.8 19" * * 6,418 4.5/11.3 * * 5400 4.5/11.3 * * 5,129 4.5/11.3 * * 4,269 4.5/11.3 * * 3,654 4.5/11.3 1,907 * 3,096 4.5/11.3 1,388 * 2,758 4.5/11.3 1,115 * 2,374 4.2/10.5 663 964 1,637 3.5/8.8 425 606 1,192 3/7.5 288 400 904 2.6/6.6 91 ⁄4" 2,572 * 4,935 2.6/6.5 1,594 2,371 3,636 2.3/5.7 1,379 2,048 3,279 2.2/5.4 819 1,208 2,269 1.8/4.5 524 766 1,661 1.5/3.9 324 466 1,188 1.5/3.5 231 327 940 1.5/3.5 184 256 801 1.5/3.5 107 140 548 1.5/3.5 68 81 396 1.5/3.5 46 48 297 1.5/3.5 91 ⁄ 2 " 2,767 * 5,094 2.7/6.7 1,718 2,556 3,825 2.4/6 1,487 2,210 3,449 2.3/5.7 884 1,306 2,387 1.9/4.7 566 829 1,747 1.6/4.1 350 505 1,250 1.5/3.5 250 355 989 1.5/3.5 199 278 843 1.5/3.5 116 153 577 1.5/3.5 73 89 417 1.5/3.5 49 53 313 1.5/3.5 111 ⁄4" * * 6,250 3.3/8.2 2,747 * 5,072 3.2/7.9 2,385 * 4,752 3.1/7.8 1,432 2,124 3,291 2.6/6.5 923 1,360 2,409 2.2/5.6 574 837 1,726 1.9/4.7 411 592 1,367 1.7/4.2 327 466 1,165 1.6/3.9 191 262 800 1.5/3.5 121 157 579 1.5/3.5 82 98 436 1.5/3.5 7" Width 117⁄ 8" * * 6,683 3.5/8.8 3,183 * 5,411 3.4/8.5 2,767 * 5,087 3.3/8.4 1,668 2,476 3,646 2.9/7.2 1,078 1,590 2,670 2.5/6.2 672 981 1,913 2.1/5.2 482 697 1,515 1.9/4.7 384 549 1,292 1.7/4.3 224 311 887 1.5/3.6 142 187 643 1.5/3.5 96 118 485 1.5/3.5 * Indicates Total Factored Resistance value controls. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 9 TJ-9505 | June 2014 14" * * 8,245 4.3/10.8 * * 6,617 4.1/10.3 * * 6,208 4.1/10.2 2,636 * 4,975 3.9/9.8 1,718 * 3,650 3.4/8.4 1,079 1,587 2,617 2.9/7.2 777 1,134 2,074 2.6/6.4 620 899 1,769 2.4/5.9 364 516 1,217 2/4.9 231 317 884 1.7/4.2 156 203 668 1.5/3.7 16" * * 8,558 4.5/11.3 * * 7,200 4.5/11.3 * * 6,838 4.5/11.3 3,788 * 5,691 4.5/11.3 2,491 * 4,703 4.3/10.9 1,576 * 3,373 3.7/9.2 1,139 1,674 2,675 3.3/8.2 911 1,332 2,282 3/7.6 538 772 1,571 2.5/6.3 343 479 1,143 2.2/5.4 231 312 865 1.9/4.8 19" * * 8,558 4.5/11.3 * * 7,200 4.5/11.3 * * 6,838 4.5/11.3 * * 5691 4.5/11.3 * * 4,872 4.5/11.3 2,543 * 4,128 4.5/11.3 1,851 * 3,677 4.5/11.3 1,487 * 3,166 4.2/10.5 884 1,285 2,183 3.5/8.8 566 808 1,590 3/7.5 384 534 1,205 2.6/6.6 BEAM DETAILS Bearing at Wall Beam to Beam Connection Bearing for Door or Window Header 11⁄8" TJ® Rim Board or 1¼" TimberStrand® LSL blocking for lateral support Strap per code if top plate is not continuous over header Strap per code if top plate is not continuous over column L1 Column Top mount hanger L2 Bearing at Concrete Wall Face mount hanger L3 Bearing at Column Beam to Column Lateral Brace TJI® joist Floor beam Strap Steel column L4 Protect untreated wood from direct contact with concrete L5 Verify beam bearing length on page 12 and column factored resistance on page 17 L14 Suggested lateral bracing detail for beams when required. Verify beam bearing length on page 12. WINDOW AND DOOR HEADER DETAILS 2x4 Wall Framing Full Depth Header Low Header High Header Header Header 2x_ nailer* Header L8 L7 L9 *Double nailer may be required depending upon the opening size and window type 2x6 Wall Framing Headers not matching wall thickness may be installed flush to the inside or outside of the wall depending upon sheathing and trim attachment requirements Low Header High Header Double top plate 2x6 wall framing L11 3½"-wide header 2x_ framing at opening 3½"-wide header L12 2x_ nailer* *Double nailer may be required depending upon the opening size and window type Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 10 TJ-9505 | June 2014 Window and Door Header Details Dropped Header with Full Lateral Bracing Framing above must be sheathed to provide lateral stability to the top of the beam Main structural header. See pages 14–16 for connecting multiple plies. One 8d (0.113" x 21/2") nail each side of joist or blocking. Blocking is required if joist framing is parallel to beam. Joist spacing must be 24" on-centre or less. Low header Nail continuous king studs to the end of the beam using: – Four 10d (0.131" x 3") nails for beams 117⁄8" deep or less – Six 10d (0.131" x 3") nails for beams 18" deep or less – Ten 10d (0.131" x 3") nails for beams greater than 18" deep L15 Fasten 2x_ plate to low header with 10d (0.131" x 3") nails at 8" on-centre, staggered Continuous king stud Dropped Header with Acceptable Lateral Bracing 4'-0" maximum height cripple wall. Wall studs at 24" on-centre, maximum. One 8d (0.113" x 2½") nail each side of joist or blocking. Blocking is required if joist framing is parallel to beam. Joist spacing must be 24" on-centre or less. Fasten 2x_ plate to header below with 10d (0.131" x 3") nails at 8" on-centre, staggered Sheathing strength axis See pages 14–16 for connecting multiple plies Nail continuous king studs to the end of the beam using: – Four 10d (0.131" x 3") nails for beams 117⁄8" deep or less – Six 10d (0.131" x 3") nails for beams 16" deep or less L16 Rated wall sheathing (7⁄16" nominal) continuous from bottom of beam to top of wall. Fasten sheathing with 8d (0.113" x 2½") nails at 6" on-centre at panel edges and 12" on-centre in panel field. Continuous king stud When framed as shown above, the following dropped headers are considered fully braced under uniform-load, simple-span conditions: Single-ply: – 1¾" wide headers, 117⁄8" deep or less – 3½" wide headers, 16" deep or less, with a maximum span of 18'-6" Multiple-ply: – Headers up to four 1¾" plies, 117⁄8" deep or less – Headers up to four 1¾" x 14" plies, with a maximum span of 8'-6" NAILING ON NARROW FACE Nails Installed on the Narrow Face Nail Size 8d (0.131" x 2½") or 10d (0.128" x 3") 10d (0.148" x 3") or 12d (0.148" x 3¼") 16d (0.162" x 3½") ■ Closest On-Centre Spacing Per Row 3½" 1¾" Microllam ® LVL TimberStrand ® LSL TimberStrand ® LSL Parallam ® PSL 3" 3" 3" 3" 4" 3" 4" 4" 6" 3½" 8" 6" If more than one row of nails is used, the rows must be offset at least ½" and staggered. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 11 TJ-9505 | June 2014 ALLOWABLE HOLES 1.55E TimberStrand® LSL Headers and Beams General Notes ■ 2 x diameter of the largest hole (minimum) 1⁄3 Allowed hole zone depth Allowed hole zone suitable for headers and beams with uniform and/or concentrated loads anywhere along member. ■ Round holes only. ■ No holes in headers or beams in plank orientation. 1.55E TimberStrand® LSL 8" Header or Beam Depth 9½" 117⁄8" 14"–16" 8" ■ Microllam® LVL and Parallam® PSL Headers and Beams See illustration for allowed hole zone. General Notes ■ Microllam® LVL and Parallam® PSL hole zone 2 x diameter of the largest hole (minimum) 1⁄ 3 depth Allowed hole zone suitable for headers and beams with uniform loads only. ■ Round holes only. ■ No holes in cantilevers. ■ No holes in headers or beams in plank orientation. Microllam® LVL and Parallam® PSL Microllam® LVL and Parallam® PSL allowed hole zone middle 1⁄3 span Header or Beam Depth 5½" 7¼"–20" ■ Larger holes in Trus Joist ® structural composite lumber may be possible; refer to Forte ® or Javelin ® software. Maximum Round Hole Size 3" 35⁄8" 45⁄8" Maximum Round Hole Size 1¾" 2" See illustration for allowed hole zone. DO NOT cut, notch, or drill holes in headers or beams except as indicated in the illustrations and tables BEARING LENGTH REQUIREMENTS Factored Reaction (lbs) 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 1.55E TimberStrand ® LSL Beam Orientation Width 1¾" 3½" 5¼" 3" 1½" 1½" 4" 2" 1½" 5" 21⁄2" 1¾" 6" 3" 2" 7" 3½" 2½" 8" 4" 2¾" 4½" 3" 5" 3½" 5½" 3¾" 6" 4" 6½" 4½" 7" 4¾" 7½" 5" 8" 5¼" 5¾" 2.0E Microllam ® LVL Beam Orientation Width 1¾" 3½" 5¼" 3¼" 1¾" 1½" 4¼" 2¼" 1½" 5¼" 2¾" 1¾" 6½" 3¼" 2¼" 7½" 3¾" 2½" 4¼" 3" 4¾" 3¼" 5¼" 3½" 6" 4" 6½" 4¼" 7" 4¾" 7½" 5" 8" 5¼" 5¾" 6" 2.2E Parallam ® PSL Beam Orientation Width 3½" 5¼" 7" 1¾" 1½" 1½" 2¼" 1½" 1½" 2¾" 1¾" 1½" 3¼" 2¼" 1¾" 3¾" 2½" 2" 4¼" 3" 2¼" 4¾" 3¼" 2½" 5¼" 3½" 2¾" 6" 4" 3" 6½" 4¼" 3¼" 7" 4¾" 3½" 7½" 5" 3¾" 8" 5¼" 4" 5¾" 4¼" 6" 4½" Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 12 General Notes ■ ■ ■ ■ Minimum bearing length: 11⁄2" at ends, 31⁄2" at intermediate supports. Bearing across full beam width required. Interpolation between reaction loads is permitted for determining bearing lengths. Bearing lengths based on the following factored bearing resistances: – 1.55E TimberStrand ® LSL: 1,165 psi. – 2.0E Microllam ® LVL: 1,090 psi. –2.2E Parallam ® PSL: 1,090 psi. TJ-9505 | June 2014 Tapered End Cuts Factored Reactions for 3½"(1) TimberStrand® LSL Headers and Beams (lbs) Bearing 3½" Wood Plate(2) 5¼" Wood Plate (2) 3½" Column(3) Beam Depth 9½"–117⁄8" 14" 16" 9½" 117⁄8"–14" 16" 9½" 117⁄8" 14" 16" 4½" 7,595 5" 7,595 7,595 8,775 8,775 9,530 9,530 8,115 8,115 8,870 8,870 8,870 Outside Heel Height D1 5½" 6" 6½" 7" 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 10,285 11,035 11,395 11,395 10,285 11,035 11,395 11,395 10,285 11,035 11,395 11,395 9,620 10,375 11,130 11,470 9,620 10,375 11,130 11,885 9,620 10,375 11,130 11,885 10,375 11,130 11,885 Minimum 3:12 slope 7½" 7,595 7,595 7,595 11,395 11,395 11,395 11,470 12,640 12,640 12,640 8" 7,595 7,595 7,595 11,395 11,395 11,395 11,470 13,395 13,395 13,395 Sloped end cut Beam depth D1 (1) For 1¾" and 5¼" beams, multiply by 0.5 and 1.5, respectively. (2) Bearing lengths are based on factored bearing resistance of 615 psi. (3) Bearing lengths are based on factored bearing resistance of 1,165 psi. Tapered end cut detailed above is not allowed with TJI® joists Factored Reactions for 3½"(1) Microllam® LVL and Parallam® PSL Headers and Beams (lbs) Bearing 3½" Wood Plate (2) 5¼" Wood Plate (2) 3½" Column (3) Beam Depth 7¼" 9¼" 9½" 11¼" 117⁄8" 14" 16" 18" 18¾"–19" 20" 7¼" 9¼" 9½" 11¼" 117⁄8" 14" 16" 18" 18¾"–19" 20" 7¼" 9¼" 9½" 11¼" 117⁄8" 14" 16" 18" 18¾"–19" 20" 4½" 7,480 7,480 7,480 7,480 7,480 8,070 8,085 8,085 8,085 8,085 8,085 7,480 7,480 7,480 7,480 7,480 5" 7,595 7,595 7,595 7,595 7,595 7,595 5½" 7,595 7,595 7,595 7,595 7,595 7,595 8,070 8,780 8,780 8,780 8,780 8,780 8,070 9,480 9,480 9,480 9,480 9,480 9,480 8,070 8,175 8,175 8,175 8,175 8,175 8,070 8,870 8,870 8,870 8,870 8,870 Outside Heel Height D1 6" 6½" 7" 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 10,175 10,175 10,175 10,175 10,175 10,175 10,175 8,070 9,565 9,565 9,565 9,565 9,565 9,565 10,295 10,575 10,870 10,870 10,870 10,870 10,870 10,870 10,260 10,260 10,260 10,260 10,260 10,260 10,260 7½" 8" 10" 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 7,595 10,295 10,575 11,395 11,395 11,395 11,395 11,395 11,395 11,395 10,295 10,575 11,395 11,395 11,395 11,395 11,395 11,395 11,395 10,575 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 11,395 10,295 10,575 10,955 10,955 10,955 10,955 10,955 10,955 10,295 10,575 11,650 11,650 11,650 11,650 11,650 11,650 11,650 10,295 10,575 12,345 12,345 12,345 12,345 12,345 12,345 12,345 12,520 13,215 13,375 13,375 13,375 13,375 13,375 Wood Plate Connection Sloped end cut Beam depth D1 Wood plate Column Connection Sloped end cut Beam depth D1 Column (1) For 13⁄4", 51⁄4", and 7" beams, multiply by 0.5, 1.5, and 2.0, respectively. (2) Bearing lengths based on a factored bearing resistance of 620 psi. (3) Bearing lengths based on factored bearing resistance of 1,090 psi for Microllam® LVL and Parallam® PSL. General Notes DO NOT overhang seat cuts on beams beyond inside face of support member No increase for duration of load is permitted above standard term. ■ ■ ■ No holes or concentrated load within tapered cut. Table considers only downward loading. Contact your Weyerhaeuser representative for assistance with uplift loading or other conditions. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 13 TJ-9505 | June 2014 MULTIPLE-MEMBER CONNECTIONs FOR SIDE-LOADED BEAMS L17 Factored Uniform Load—Maximum Factored Uniform Load Applied to Either Outside Member (PLF) Fastener Pattern Assembly A Fastener Type 10d (0.128" x 3") Nail(1) ½" A307 Through Bolt (2)(3) SDS (3) USP WS (3) TrussLOK-EWP™(3) SDW22(3)(4) Assembly B Assembly C Assembly D Assembly E 2" 2" 2" 2" Fastener 13⁄4" 13⁄4" 13⁄4" 31⁄2" Number On-Centre Location of Rows Spacing 3½" wide, 2-ply 5¼" wide, 3-ply 5¼" wide, 2-ply 2(5) 12" 575 430 430 As shown 3 12" 865 650 650 24" 780 585 880 – 2 19.2" 975 730 1,095 16" 1,170 880 1,315 Screw Length 3½" 3½" 3½" 24" 870 655 655 As shown 2 19.2" 1,090 815 815 16" 1,305 980 980 24" 905 680 680 As shown 2 19.2" 1,130 850 850 16" 1,355 1,015 1,015 Screw Length 33 ⁄8" 5" 33 ⁄8" 24" 585 550 440 One side 2 19.2" 735 685 550 only 16" 880 825 660 24" 680 625 585 One side 2 19.2" 850 780 730 only 16" 1,020 935 880 Assembly F 2" 2" 13⁄4" 31⁄2" 13⁄4" 31⁄2" 7" wide, 3-ply 385 575 780 975 1,170 3½" 580 725 870 605 755 905 6¾" 490 610 730 555 690 830 7" wide, 2-ply 7" wide, 4-ply 1,560 1,950 2,340 6" 2,040 2,550 3,060 520 650 780 6" 680 850 1,020 765(6) 960(6) 1,150(6) 6¾" 490 610 730 555 690 830 13⁄4" 6¾" 730 915 1,100 1,140 1,425 1,710 (1) Nailed connection values may be doubled for 6" on-centre or tripled for 4" on-centre nail spacing. (2) Washers required. Bolt holes to be 9⁄16" maximum. (3) Factored resistance for 24" on-centre bolted or screwed connection values may be doubled for 12" on-centre spacing. (4) When loading the head side of a SDW22 screw, assemblies A, B, D, and F can be increased by 15%. (5) For beams up to 14" deep, maximum. (6) Assembly F is not recommended for TimberStrand® LSL or Parallam® PSL. General Notes for Side-Loaded Beam Tables ■ ■ ■ ■ ■ ■ ■ ■ Uniform Load Design Example Connections are based on Limit States Design per CSA O86. Use specific gravity of 0.5 when designing lateral connections. Values listed are for standard term loading. When fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. Verify adequacy of beam in allowable load tables on pages 5–9. 7" wide beams should be side-loaded only when loads are applied to both sides of the members (to minimize rotation). Minimum end distance for bolts and screws is 6". Beams wider than 7" require special consideration by the design professional of record. 435 PLF 625 PLF First, check load tables on pages 5–9 to verify that three pieces can carry the total factored load of 1,060 plf with proper live load deflection criteria. Total factored load = (1.25 x dead load) + (1.5 x live load). Maximum f actored load applied to either outside member is 625 plf. For an assembly of three 1¾" plies (Assembly B), two rows of 10d (0.128" x 3") nails at 12" on-centre is good for only 430 plf. Therefore, use three rows of 10d (0.128" x 3") nails at 12" on-centre (good for 650 plf). Alternatives: Two rows of 1⁄2" bolts or 5" TrussLOK-EWP™ screws at 19.2" on-centre. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 14 TJ-9505 | June 2014 MULTIPLE-MEMBER CONNECTIONs for side-Loaded Beams L18 Factored Point Load—Maximum Factored Point Load Applied to Either Outside Member (lbs) Fastener Pattern Assembly A Fastener Type 10d (0.128" x 3") Nail ½" A307 Through Bolt (1) SDS USP WS TrussLOK-EWP™ SDW22(2) Number of Fasteners Location per Side 6 12 As shown 18 24 4 – 6 8 Screw Length 4 As shown 6 8 4 6 As shown 8 Screw Length 4 One side only 6 8 4 One side only 6 8 Assembly B Assembly C Assembly D Assembly E 2" 2" 2" 2" 13⁄4" 13⁄4" 31⁄2" 13⁄4" 3½" wide, 2-ply 1,730 3,455 5,185 6,910 3,120 4,680 6,240 3½" 3,480 5,220 6,960 3,615 5,425 7,230 33 ⁄8" 2,345 3,515 4,690 2,720 4,080 5,440 5¼" wide, 3-ply 5¼" wide, 2-ply 1,295 1,295 2,590 2,590 3,890 3,890 5,185 5,185 2,340 3,510 3,510 5,265 4,680 7,020 3½" 3½" 2,610 2,610 3,915 3,915 5,220 5,220 2,710 2,710 4,070 4,070 5,425 5,425 5" 33 ⁄8" 2,195 1,760 3,295 2,635 4,390 3,515 2,490 2,340 3,735 3,510 4,980 4,680 Assembly F 2" 2" 13⁄4" 31⁄2" 13⁄4" 31⁄2" 7" wide, 3-ply 7" wide, 2-ply 2,305 3,455 4,610 3,120 4,680 6,240 3½" 2,320 3,480 4,640 2,410 3,615 4,820 6¾" 1,950 2,930 3,905 2,215 3,320 4,425 13⁄4" 7" wide, 4-ply 6,240 9,360 12,480 6" 8,160 12,240 16,320 2,080 3,120 4,160 6" 2,720 4,080 5,440 3,065(3) 4,600(3) 6,135(3) 6¾" 1,950 2,930 3,905 2,215 3,320 4,425 6¾" 2,930 4,390 5,855 4,560 6,840 9,120 (1)Washers required. Bolt holes to be 9⁄16" maximum. (2)When loading the head side of a SDW22 screw, assemblies A, B, D, and F can be increased by 15%. (3) Assembly F is not recommended for TimberStrand® LSL or Parallam® PSL. 3,000 lbs Point Load Design Example First, verify that three plies of 1¾" x 14" beam material is capable of supporting the factored 3,000 lb point load, as well as all other loads applied. The factored 3,000 lb point load is being transferred to the beam with a face mount hanger. For an assembly of three 1¾" plies, six 5"-long TrussLOK-EWP™ screws are good for 3,295 lbs with a face mount hanger. 14" Point Load Connector Spacing 4- or 6-Bolt or Screw Connection ½" A307 through bolt, or SDS, USP WS, TrussLOK-EWP™, or SDW screw, typical 8-Bolt or Screw Connection ½" A307 through bolt, or SDS, USP WS, TrussLOK-EWP™, or SDW screw, typical Nail Connection 10d (0.128" x 3" nails, typical. Stagger to prevent splitting. 2" spacing, typical 1½" minimum 2" minimum at top and bottom, typical 1½" minimum Equal spacing ½ beam depth L19 Minimum beam depth is 9½" for ½" diameter bolts 2" minimum 2" minimum 8"–10" 2" minimum 2" minimum L20 Minimum beam depth is 117⁄8 " for ½" diameter bolts Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 15 1½" minimum spacing, typical L21 There must be an equal number of nails on each side of the connection TJ-9505 | June 2014 MULTIPLE-MEMBER CONNECTIONs FOR TOP-LOADED BEAMS Fastener Installation Requirements Piece Width Number of Plies 2 1¾" 3 Type (1) 10d nails 12d–16d nails Screws 10d nails 12d–16d nails Min. Length 3" 3¼" 33∕8" or 3½" 3" 3¼" 33∕8" or 3½" 5" 3" 3¼" 5" or 6" 6¾" 5" or 6" 6¾" 8" Screws 4 10d nails(3) 12d–16d nails(3) Screws 3½" 2 Screws ½" bolts Metric to Imperial Conversions Fastener # Rows 3(2) 2(2) 2 3(2) 2(2) O.C. Spacing Location 12" One side 24" One side 12" Both sides 2 24" 3(2) 2(2) 12" 2 24" 2 24" Metric Unit 1 kN 1N 1m 1 mm 1 kg 1N•m 1N•m 1 mm 4 1 Pa 1 kPa Both sides One side One side (per ply) Both sides One side Both sides One side – Imperial to Metric Conversions Imperial Unit 1 kip 1 lb 1 ft 1 in. 1 lb mass 1 lb • ft 1 lb • in. 1 in. 4 1 lb/ft 2 1 lb/in. 2 (1)10d nails are 0.128" diameter; 12d–16d nails are 0.148"–0.162" diameter; screws are SDS, USP WS, TrussLOK-EWP™ or SDW. (2)An additional row of nails is required with depths of 14" or greater. (3)When connecting 4-ply members, nail each ply to the other and offset nail rows by 2" from the rows in ply below. hen fasteners are required on both sides, stagger W fasteners on the second side so they fall halfway between fasteners on the first side. Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams L6 Imperial Conversion 0.2248 kip 0.2248 lb 3.281 ft 0.0394 in. 2.205 lb mass 0.7376 lb • ft 8.851 lb • in. 2.402 x 10-6 in.4 0.0209 lb/ft2 0.1450 lb/in.2 Metric Conversion 4.448 kN 4.448 N 0.3048 m 25.40 mm 0.4536 kg 1.356 N • m 0.1130 N • m 0.4162 x 106 mm4 47.88 Pa 6.895 kPa Multiple pieces can be nailed or bolted together to form a header or beam of the required size, up to a maximum width of 7" header design example problem 1.Unfactored live load: Case 2: 1.0 x 360 + 0.5 x 600 = 660 plf Case 3: 1.0 x 600 + 0.5 x 360 = 780 plf Therefore use Case 3 at 780 plf 2.Unfactored total load: For Cases 2 and 3: Unfactored dead load = 1.0 x 490 = 490 plf Unfactored total load = 780 plf + 490 plf = 1,270 plf Rough opening 1⁄2 House width maximum 3.Factored total load: Case 2: 1.5 x 360 + 0.5 x 600 = 840 plf Case 3: 1.5 x 600 + 0.5 x 360 = 1,080 plf Therefore use Case 3 at 1,080 plf Factored dead load = 1.25 x 490 = 613 plf Factored total load = 1,080 + 613 = 1,693 plf House width Try using a 31⁄2" x 117⁄8" 1.55E TimberStrand® LSL header. See page 5 of this guide. Determine the size of 1.55E TimberStrand® LSL header required for a 10' rough opening for the given loads and assumptions: ■ ■ ■ ■ 1.55E TimberStrand® LSL: Floor and /or Snow—Standard Span House width = 36' Trussed roof with 24" roof truss overhangs Roof Load = 30 psf snow + 15 psf dead Floor Load = 40 psf live + 12 psf dead 10' 12' Calculated unfactored plf loads acting on the beam (20' roof and 9' floor tributary): ■ ■ ■ Summary: Snow = 600 plf Floor = 360 plf Dead = 490 plf (includes wall load at 80 plf) Condition Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) Unfactored Resistance (LL) Unfactored Resistance (TL) Total Factored Resistance Min. End/Int. Bearing (in.) 9½" 524 775 1,373 1.7/4.3 311 457 950 3½" Width 14" 117⁄8" 975 1,520 1,449 * 2,106 2,886 2.6/6.5 3.6/8.9 588 929 868 1,378 1,457 1,998 16" 2,155 * 3,645 4.5/11.3 1,335 * 2,581 9½" 786 1,163 2,060 1.7/4.3 467 685 1,424 5¼" Width 16" 9¼" 2,155 729 * 1,078 3,645 1,957 4.5/11.3 1.7/4.1 1.Unfactored Resistance (LL) = 975 > 780 OK 2.Unfactored Resistance (TL) = 1,449 > 1,270 OK 3.Total Factored Resistance = 2,106 > 1,693 OK Next, calculate design loads per 2010 NBCC load combinations (primary load and companion load action). Therefore, a 3½" x 117⁄8" 1.55E TimberStrand® LSL header is acceptable. The beam requires 2.6" of bearing at end supports and 6.5" of bearing at intermediate support. Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 16 TJ-9505 | June 2014 9½" 786 1,163 2,060 1.7/4.3 11¼" 1,260 1,872 2,848 2.4/5.9 2 Parallam® PSL Columns Axial Factored Resistances (lbs) for 1.8E Parallam® PSL Column Bearing Type On Column Base Effective Column Length 6' 7' 8' 9' 10' 12' 14' 16' 18' 20' 22' 24' Column Size 3½" x 3½" 3½" x 5¼" 3½" x 7" 5¼" x 5¼" 5¼" x 7" 7" x 7" 15,342 13,216 11,227 9,450 7,910 5,522 3,892 23,013 19,823 16,841 14,175 11,871 8,287 5,837 30,684 26,431 22,455 18,900 15,821 11,048 7,782 43,054 40,209 37,152 34,003 30,869 24,964 19,853 15,664 12,357 9,773 57,406 53,612 49,536 45,338 41,160 33,285 26,470 20,885 16,464 13,030 81,855 78,921 75,642 71,899 67,984 59,793 51,644 43,999 37,135 31,166 26,111 21,852 Slenderness ratio exceeds 50 The column values listed are for dry-service only. When wet-service conditions exist, contact your Weyerhaeuser representative for other product solutions. conditions Wide face of strands DO NOT install bolts or screws into the narrow face of strands General Notes Tables are based on: –Solid, one-piece column members used in dry‑service conditions. – Bracing in both directions at column ends. –CSA O86. –Simple columns with axial loads only. For side loads or other combined bending and axial loads, see the CSA O86 provisions. –KD = 1.0, where the specified snow or live load is greater than the specified dead load. For other load cases, use Weyerhaeuser software. ■ ■ ■ Wide face of strands Factored resistances have been adjusted to accommodate the worst case of the following eccentric conditions: 1⁄6 of column thickness (first dimension) or 1⁄6 of column width. In order to use the manufacturer’s published capacities when designing column caps, bases, or holdowns for uplift, the bolts or screws must be installed perpendicular to the wide face of strands, as shown above. Beams and columns must remain straight to within 5L2⁄4608 (in.) of true alignment. L is the unrestrained length of the member in feet. For column specified strengths see page 4. Top or Bottom Plate Connection Beam on Column Cap P1 Two 16d (0.162" x 3½") nails for every 1¾" of column width, nailed through the plate into the column Column Base P2 Elevated Column Base Beam on Column 11⁄8" TJ® Rim Board or 1¼" TimberStrand® LSL blocking for lateral support Optional non-shrink grout Strap per code if top plate is not continuous over column Column P3 L1 Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 17 TJ-9505 | June 2014 NOTES Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 18 TJ-9505 | June 2014 NOTES Trus Joist® Beam, Header, and Column Specifier’s Guide (W. Canada) 19 TJ-9505 | June 2014 We Can Help You Build Smarter You want to build solid and durable structures—we want to help. Weyerhaeuser provides high-quality building products and unparalleled technical and field assistance to support you and your project from start to finish. Floors and Roofs: Start with the best framing components in the industry: our Trus Joist® TJI® joists; TimberStrand® LSL rim board; and TimberStrand® LSL, Microllam® LVL, and Parallam® PSL headers and beams. Pull them all together with our self-gapping and self-draining Weyerhaeuser Edge Gold™ floor panels and durable Weyerhaeuser roof sheathing. Walls: Get the best value out of your framing package—use TimberStrand® LSL studs for tall walls, kitchens, and bathrooms, and our traditional, solid-sawn lumber everywhere else. Cut down installation time by using TimberStrand® LSL headers for doors and windows, and Weyerhaeuser wall sheathing with its handy two-way nail lines. Software Solutions: Whether you are a design professional or lumber dealer, Weyerhaeuser offers an array of software packages to help you specify individual framing members, create cut lists, manage inventories—even help you design a complete structural frame. Contact your Weyerhaeuser representative to find out how to get the software you need. Technical Support: Need technical help? Weyerhaeuser has one of the largest networks of engineers and sales representatives in the business. Call us for help, and a skilled member from our team of experts will answer your questions and work with you to develop solutions that meet all your structural framing needs. CONTACT US 1.888.453.8358 • woodbywy.com/contact Contact your local representative or dealer at: Visit woodbywy.com/warranty for copies of this and other Trus Joist® Engineered Wood Product warranties. June 2014 • Reorder TJ-9505 This document supersedes all previous versions. If this is more than one year old, contact your dealer or Weyerhaeuser rep. , Weyerhaeuser, Microllam, Parallam, TimberStrand, TJ, TJI, and Trus Joist are registered trademarks and Edge Gold and TJ-Pro are trademarks of Weyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved. Printed in the USA.
© Copyright 2024