Light band BLA 50A-001-S115 BLA0001 LASER CLASS 1 per IEC 60825-1: 2003-10 1) Emitter 2) Display and control panel 3) Receiver Light band Series A Laser red light General attributes Additional features Polarity reversal protected Series Object number binary coded via 3 switching outputs. Key (4x) CE IEC 60947-5-2 IP65 CCD signal - OLED display Setting menu - OLED display Power - LED GN Switching tol. - OLED display Object in meas. field - LED OG Object number - OLED display Meas.field limits - OLED disp. Object visualiz.- OLED display Object mode - OLED display Measuring mode - OLED display Analog meas.val. - OLED displ. yes Series A Internet Balluff Germany Balluff USA Balluff China www.balluff.com +49 (0) 7158 173-0, 173-370 1-800-543-8390 +86 (0) 21-50 644131 Adjuster Approvals / Conformity Basic standard Enclosure Type per IEC 60529 Indicator Setting Short circuit protected Meas. mode (analog output) Object mode (digital output) Meas.field limits Factory setting (reset) Key disable on/off Output active/inactive Output curve rise/fall Analog output U/I Teach in objects (max. 6) Switching tol. ± 0.1...2 mm Read dir. of the OLED display Contrast of the OLED display OLED display on/off Display mode of the OLED disp. Normalize CCD signal Calibrate analog outputs Align via CCD signal disp. yes Electrical attributes Analog output Connection type Eff. operating current Ie Eff. operating voltage Ue DC Electrical version Load capacitance max. (at Ue) Load res. RL max. (analog I) Load res. RL min. (analog U) No-load current max. Io at Ue Analog U/I (2x) Connector 100 mA 24.0 V DC, direct current 1.00 µF 500 Ohm 500 Ohm 100 mA For definitions of terms, see main catalog Subject to change BLA0001_235849_07/04/151(3) Light band BLA 50A-001-S115 BLA0001 Operating voltage UB max. DC [V] Operating voltage UB min. DC [V] Output curve deviation max. Rated insulation voltage Ui Ripple max. (% of Ue) Switching function Switching output Value range analog Mechanical attributes Ambient temperature Ta max. Ambient temperature Ta min. Connector type 30.0 V 15.0 V 100 µm (R0 < 2m) 50 µm (R0 < 1m) 20 µm (R0 < 0.25m) 75 V DC 10 % NO PNP (3x) 0...10 V / 4...20 mA Housing material Length 1 Length 2 Length 3 Mounting type Operating range Ro Range Sn 55 °C 5 °C M12x1-S04 M12x1-B04, M12x1-S115 Aluminum 26.0 mm 15.0 mm 100.0 mm Screw M4 0...2 m Sn = 2 m Internet Balluff Germany Balluff USA Balluff China www.balluff.com +49 (0) 7158 173-0, 173-370 1-800-543-8390 +86 (0) 21-50 644131 Repeat accuracy Resolution Sensing face material Style Surface protection 10 µm (R0 < 0.25m) 20 µm (R0 < 1m) 40 µm (R0 < 2m) 0.01 mm Glass Block, straight connection Anodized Optical attributes Active length AL Average power Po max. Laser Class per IEC 60825-1 Light type Optical special feature Principle of optical operation Wavelength AL = 50 mm < 390 µW (IEC 60825-1) 1 Laser red light CCD technology Through-beam 650 nm Additional text For additional information, refer to user's guide. Do not press key using a pointed tool. Connection cable and cable connection included in the scope of delivery, order other accessories separately. The sensor is functional again after the overload has been eliminated. Reference object (test target): Steel cylinder, diameter 8.0 mm. For definitions of terms, see main catalog Subject to change BLA0001_235849_07/04/152(3) Light band BLA 50A-001-S115 BLA0001 1) Object mode digital outputs 2) No. of identified object 3) Meas. mode analog output 1 4) Meas. value analog output 1 5) Discard selection, back 6) scroll / increase value 7) Menu, confirm selection 8) Object in meas. field 9) Operating voltage 10) scroll / decrease value 11) Meas.value analog output 2 12) Vis. meas.field and object 13) Meas. mode analog output 2 14) Switching tol. dig. output Internet Balluff Germany Balluff USA Balluff China www.balluff.com +49 (0) 7158 173-0, 173-370 1-800-543-8390 +86 (0) 21-50 644131 For definitions of terms, see main catalog Subject to change BLA0001_235849_07/04/153(3)
© Copyright 2024