BLA 50A-001-S115 BLA0001

Light band
BLA 50A-001-S115
BLA0001
LASER CLASS 1 per IEC 60825-1:
2003-10
1) Emitter 2) Display and control panel 3) Receiver
„„ Light band
„„ Series A
„„ Laser red light
General attributes
Additional features
Polarity reversal protected
Series
Object number binary coded via 3
switching outputs.
Key (4x)
CE
IEC 60947-5-2
IP65
CCD signal - OLED display
Setting menu - OLED display
Power - LED GN
Switching tol. - OLED display
Object in meas. field - LED OG
Object number - OLED display
Meas.field limits - OLED disp.
Object visualiz.- OLED display
Object mode - OLED display
Measuring mode - OLED display
Analog meas.val. - OLED displ.
yes
Series A
Internet
Balluff Germany
Balluff USA
Balluff China
www.balluff.com
+49 (0) 7158 173-0, 173-370
1-800-543-8390
+86 (0) 21-50 644131
Adjuster
Approvals / Conformity
Basic standard
Enclosure Type per IEC 60529
Indicator
Setting
Short circuit protected
Meas. mode (analog output)
Object mode (digital output)
Meas.field limits
Factory setting (reset)
Key disable on/off
Output active/inactive
Output curve rise/fall
Analog output U/I
Teach in objects (max. 6)
Switching tol. ± 0.1...2 mm
Read dir. of the OLED display
Contrast of the OLED display
OLED display on/off
Display mode of the OLED disp.
Normalize CCD signal
Calibrate analog outputs
Align via CCD signal disp.
yes
Electrical attributes
Analog output
Connection type
Eff. operating current Ie
Eff. operating voltage Ue DC
Electrical version
Load capacitance max. (at Ue)
Load res. RL max. (analog I)
Load res. RL min. (analog U)
No-load current max. Io at Ue
Analog U/I (2x)
Connector
100 mA
24.0 V
DC, direct current
1.00 µF
500 Ohm
500 Ohm
100 mA
For definitions of terms, see main catalog
Subject to change
BLA0001_235849_07/04/151(3)
Light band
BLA 50A-001-S115
BLA0001
Operating voltage UB max. DC [V]
Operating voltage UB min. DC [V]
Output curve deviation max.
Rated insulation voltage Ui
Ripple max. (% of Ue)
Switching function
Switching output
Value range analog
Mechanical attributes
Ambient temperature Ta max.
Ambient temperature Ta min.
Connector type
30.0 V
15.0 V
100 µm (R0 < 2m)
50 µm (R0 < 1m)
20 µm (R0 < 0.25m)
75 V DC
10 %
NO
PNP (3x)
0...10 V / 4...20 mA
Housing material
Length 1
Length 2
Length 3
Mounting type
Operating range Ro
Range Sn
55 °C
5 °C
M12x1-S04
M12x1-B04, M12x1-S115
Aluminum
26.0 mm
15.0 mm
100.0 mm
Screw M4
0...2 m
Sn = 2 m
Internet
Balluff Germany
Balluff USA
Balluff China
www.balluff.com
+49 (0) 7158 173-0, 173-370
1-800-543-8390
+86 (0) 21-50 644131
Repeat accuracy
Resolution
Sensing face material
Style
Surface protection
10 µm (R0 < 0.25m)
20 µm (R0 < 1m)
40 µm (R0 < 2m)
0.01 mm
Glass
Block, straight connection
Anodized
Optical attributes
Active length AL
Average power Po max.
Laser Class per IEC 60825-1
Light type
Optical special feature
Principle of optical operation
Wavelength
AL = 50 mm
< 390 µW (IEC 60825-1)
1
Laser red light
CCD technology
Through-beam
650 nm
Additional text
For additional information, refer to user's guide.
Do not press key using a pointed tool.
Connection cable and cable connection included in the scope of delivery, order other
accessories separately.
The sensor is functional again after the overload has been eliminated.
Reference object (test target): Steel cylinder, diameter 8.0 mm.
For definitions of terms, see main catalog
Subject to change
BLA0001_235849_07/04/152(3)
Light band
BLA 50A-001-S115
BLA0001
1) Object mode digital outputs 2) No. of identified object 3) Meas. mode analog output 1 4) Meas. value analog output 1 5) Discard selection, back 6) scroll / increase value 7) Menu, confirm selection 8) Object in meas. field 9) Operating voltage 10) scroll / decrease value 11) Meas.value analog output 2 12) Vis. meas.field and object 13) Meas.
mode analog output 2 14) Switching tol. dig. output
Internet
Balluff Germany
Balluff USA
Balluff China
www.balluff.com
+49 (0) 7158 173-0, 173-370
1-800-543-8390
+86 (0) 21-50 644131
For definitions of terms, see main catalog
Subject to change
BLA0001_235849_07/04/153(3)