BFL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS! READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY DISCONNECT AC POWER SUPPLY BEFORE SERVICING. Installation and servicing of this equipment should be performed by qualified service personnel only. Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable. Do not mount near gas or electrical heaters. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any modification or use of non-original components will void the warranty and product liability. • Do not use this equipment for other than intended use. • • • • • The specialtyLED BFL is made up of flexible linear trac that has LED lamp holders installed on 2” or 4” centers based on the customer’s requirements. INSTALLATION INSTRUCTIONS SAFETY PRECAUTIONS: • It is recommended that you do not cover the product unless done so with extreme caution and attention to ventilation. • Do not cut, shorten or splice power cord. • Do not route through walls, doors, windows or building structures. • Do not apply power when tightly coiled. Maintain half inch spacing between parts. • During installation, do not scratch tampered glass lense as this will affect the optics of the unit. • Do not submerge in liquid or apply near standing water. • Do not secure power cables with staples, nails or like means that can damage the insulation on the cables. • Do not mount inside cabinets, tanks or enclosures unless properly ventilated. • Do not unroll on a rough surface or over sharp corners. • Do not operate in temperatures exceeding 149°F (65°C). • Ground Fault Interrupter (GFCI) protection should be provided on all circuits. • Do not operate on circuits that do not have proper surge suppression protection. High voltage spikes will damage the LEDs. • Do not operate over the specified voltage or current. • Do not leave any part unsecured. Movement over time from weather can cause damage from continuous movement. • Do no operate if power cord jacket is damaged or internal wires are visible. 40070011 REV 1 11/2014 1 800.533.3948 • www.barronltg.com BFL INSTALLATION INSTRUCTIONS General Material/Tool Requirements: Material needed for installation: BFL Roll 12V or 24V Transformer BFL Accessories as needed Measuring tape Scissors Wire cutters Screw driver 1. Measure the installation location to determine product length. 2. Measure the BFL to match required installation length. BFL can be cut along the 2 conductor stranded wires. 3. Using a wire cutter, make an even cut through product. (Fig. 1) Fig. 1 Cut NOTE: It is imperative to use a sharp cutting blade to make a straight cut. Sharp blades will help you avoid pulling the internal circuitry while making the cut. Stretching or pulling the product can result in damage. 4. Position BFL in the intended location. 5. Anchor mounting clip (BFL-MC). Place using appropriate hardware for application. Place mounting clips every 6’ 6. Install LED lamps (Fig. 2) into holders, snapping firmly in place. Alignment of lamps can be done a this time. (Fig. 3) Fig. 2 Fig. 3 7. Install end cap (BFL-EC) on end of trac. 8. Install terminal block inside Junction Box (BFL-JB). 9. Connect fixture wires to terminal block (BFL-TB), and transformer wires to other side of terminal block. Note: Transformer wattage can be determined by the following equation; # LED Lamps X 1.00 Watt/Lamps = Transformer wattage. Example: 5’ of product with LED lamps installed every 4” for a total of 15 lamps 15 lamps X 1.00 Watt/Lamps = 15 Watts Recommended transformer XFMR-12-20 10. Finalize 120V connection per NEC and local jurisdiction. 40070011 REV 1 11/2014 2 800.533.3948 • www.barronltg.com
© Copyright 2024