Bilaga 9 Ljudberäkningar - Bevara Gunnilstorp/Tranhult

Bilaga 9 Ljudberäkningar
Gunnilstorp Wind Farm – Noise Propagation Assessment – Summary Report
Site
Client
Date
Document
Prepared
Checked
Authorised
Gunnilstorp Wind Farm
Gunnilstorp Tranhult Vindkraft AB
29/04/2013
1029639/1/B
Daniel Marmander
Edmund Andrew
Rachel Seed
Noise modelling
The noise calculation model suggested by Swedish “Naturvårdsverket” in the report 6241 “Ljud från vindkraftverk”, was used when calculating the noise levels
presented in this report. The k parameter was set to zero, since the turbine noise for the turbines in question do not increase for higher wind speeds. The
roughness parameter was set to 0.05, although setting the k parameter to zero renders the result fully independent of the roughness parameter.
Sound data for Siemens SWT-2.3-113 turbine at 142.5 m hub height was used to model turbine noise for the Gunnilstorp layout. The octave band spreading was
obtained from Siemens; document “E R WP SP EN-10-0000-0247-00”. Sound data for the turbine model is presented in Table B-1, Annex B.
The locations of noise sensitive properties (NSPs) have been obtained from the Client. The predicted noise levels are presented in Table 1. The site layout used
for the noise calculation is detailed in Table A-1, Annex A. A map detailing the layout, noise sensitive points and ISO lines for noise propagation is presented in
Figure C-1, Annex C. All coordinates are given in Sweref 99 TM.
ID
Easting
Northing
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
429479
429181
429422
429519
431347
431394
431431
431482
431266
434842
435660
435416
435558
435510
435548
435211
433629
435109
431647
431792
433609
433322
429997
430046
430032
431162
433862
434082
435203
435180
431379
431420
6366995
6366434
6366138
6365877
6366028
6366122
6366084
6365906
6368531
6365599
6366194
6367097
6367393
6367646
6368242
6368790
6369114
6368996
6369466
6369613
6369136
6369651
6368978
6369083
6369335
6365556
6369765
6370167
6369998
6370039
6366096
6365806
Calculated
noise
levels
(dB(A))
30.6
29.1
28.8
28.4
33.0
33.4
33.5
33.1
35.9
32.4
29.7
31.1
30.3
30.3
29.4
29.6
33.0
29.5
37.1
37.4
33.0
33.1
36.2
36.6
37.5
31.1
31.6
30.8
28.2
28.2
33.3
32.6
Table 1 Coordinates and calculated noise levels at specified noise sensitive points.
The Green House, Forrest Estate, Dalry, Castle Douglas, DG7 3XS, Scotland, UK
www.naturalpower.com [email protected] Tel: +44 (0) 1644 430 008
ID
Easting
Northing
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
431100
432962
432956
431496
431368
431380
431791
431806
431336
429696
429907
431474
431471
431734
430426
430481
430512
428280
428313
428381
428354
428256
428410
428355
426729
427933
429687
430016
430036
430676
430034
430028
430024
429887
430368
431396
431405
427999
428080
6365928
6370717
6370771
6372060
6372111
6372277
6372233
6372339
6372316
6369066
6369103
6372853
6373097
6372832
6373508
6373519
6373552
6373089
6372936
6372662
6372633
6372498
6372380
6372347
6370221
6369487
6369048
6369325
6369869
6368332
6369508
6369595
6369132
6369097
6373768
6373386
6373746
6373181
6373351
Calculated
noise
levels
(dB(A))
31.9
34.5
34.5
39.3
39.8
39.2
37.5
37.2
39.3
36.9
36.8
37.1
36.4
36.1
38.7
38.5
38.2
37.0
37.6
38.7
38.7
38.7
39.7
39.6
36.4
39.0
36.8
37.6
39.8
34.6
38.3
38.6
36.8
36.7
37.4
35.7
34.3
35.6
35.4
Table 1 Coordinates and calculated noise levels at specified noise sensitive points.
The Green House, Forrest Estate, Dalry, Castle Douglas, DG7 3XS, Scotland, UK
www.naturalpower.com [email protected] Tel: +44 (0) 1644 430 008
ANNEX A – Turbine coordinates
ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Easting
428825
428409
429536
430859
430172
429608
429823
427698
429116
429039
431487
429764
428800
430346
428118
431371
429428
430481
432651
433514
432201
433162
433583
Northing
6371104
6370400
6372990
6370795
6371802
6371481
6372603
6370459
6371655
6370511
6371055
6372090
6370008
6372473
6371011
6370541
6370959
6371248
6366988
6366216
6367996
6366559
6367123
Table A-1 Coordinates for Gunnilstorp wind farm.
ANNEX B – Turbine Sound Power Levels
Octave band (Hz)
63
125
250
500
1000
2000
4000
8000
All
Equivalent band
level (dB(A))
79.1
92.1
98.3
99.2
98.8
97.8
90.7
74.3
105.0
Table B-1 Octave band levels for Siemens SWT-2.3-113 running at “Standard setting”.
Annex C – Sound propagation map