Turbine Studio Technical Specifications

TURBINE STUDIO
TECHNICAL SPECIFICATIONS
Version 3.0 – 11/5/2015
Auditorium Seating
The Turbine Studio is a flat floor non fixed seating venue, allowing the seating to be configured as per show requirements. The venue has
a maximum capacity of 150. The standard Theatre Mode configuration typically has a small stage located at the north end of the space and
10 rows of 15 seats making a capacity of 150. The venue is supplied as a black box with no stage or seating but can be installed as a cost
to the hirer.
Staging
Brisbane Powerhouse has a limited supply of staging and rigging equipment available. Additional rigging equipment is available for hire.
Please note all rigging must be installed by a licensed rigger. Brisbane Powerhouse can provide a licensed rigger for a fee if required.
Additional staging equipment, including soft blacks, rostra and treads, are also available for hire. Please contact Brisbane Powerhouse for
the complete list of equipment.
RIGGING

Fixed grid of 48mm heavy wall steel scaffold pipe

Grid height is 3.3 m to the underside of the pipe

60kg per meter distributed load

200kg point load
STAGE FLOOR
The stage is a sprung timber dance floor. The top deck is masonite. The floor has a 750kg per square meter distributed load.
ROOM DIMENSIONS

13.5 m x 10.7 m
DRAPES
The venue comes supplied with gathered black wall masking.
Page 1 of 3
TURBINE STUDIO
TECHNICAL SPECIFICATIONS
Version 3.0 – 11/5/2015
Lighting
The lighting grid is a fixed scaffold grid with a height to the underside of the pipe of 3.3m. All patching is achieved with 4 circuit looms as
there are no patch outlets in the grid. For point loads and rigging information refer to rigging section across. Additional lighting equipment
is available for hire. Please contact Brisbane Powerhouse for the complete list of equipment available for hire.
LIGHTING FIXTURES

2 X Source 4 Junior 26o

2 X Source 4 Junior 50o

8 X Selecon Acclaim PC

4X Selecon acclaim Fresnel

4X Selecon acclaim 24/44 zoomspot

5 X Selecon acclaim 18/34 zoomspot

6 X LEDForce 7 RGBW mini led par with barn doors
ACCESSORIES

Various accessories such as gobo holders and iris may be available at hirer’s request.

6 Wieland looms with 4-circuit bar headers
LIGHTING CONTROL

1 x ETC Element 60

1 x LSC e24 24 way dimmer rack with 3 Aux power outputs
Power
The Turbine Studio has two 40A 3 phase outlets located at the rear of the room in the OP corner. They are normally both used for the
Lighting System.
Stage Management System
There is no Stage Management System located in the Turbine Studio.
Sound
The Audio system in the Turbine Studio currently comprises 2 x Martin F15+ cabinets and an 18” Martin sub powered by two QSC 236
Amplifiers. Mixing consoles available include the Yamaha LS9-32 or 16; the Soundcraft ZED10 or the Studiomaster GB2-24 as requested.
Leads, power adapters and interconnects are available as part of the venue hire and additional audio equipment such as Graphics and
Monitor speakers may be available on request – please contact the Brisbane Powerhouse for a more extensive list of equipment.
MICROPHONES/DI

2 x Shure SM58 microphones

2 x Shure SM57 microphones
A more extensive range of mics is available, upon hirer’s request.
Page 2 of 3
TURBINE STUDIO
TECHNICAL SPECIFICATIONS
Version 3.0 – 11/5/2015
Pianos
Brisbane Powerhouse has the following pianos available for hire:

1 x Yamaha 88 key Upright piano

1 x 5’1” Boston 88 key Baby Grand piano
Miscellaneous
Assistive Listening System
There is no assistive listening equipment installed in the Turbine Studio.
Fire Evacuation and Work Place Health and Safety Induction
All visiting clients, including crew and cast, must undergo a venue specific induction regarding fire evacuation and workplace health
and safety. A copy of the Brisbane Powerhouse fire evacuation procedure is available on request. It is a requirement of Brisbane
Powerhouse Work Place Health and Safety that closed-in shoes are worn on stage for all site inspections, bump in and bump outs.
Smoking Policy
The Brisbane Powerhouse is a non-smoking venue. Persons who smoke are required by law to smoke only in Designated Smoking
Areas.
Risk Assessment
Shows which are deemed to contain an item or event that may cause a potential hazard may be required to complete a risk
assessment in consultation with Brisbane Powerhouse.
Insurance
Details of insurance provided with venue contract.
Page 3 of 3