I m p l e m e n t a t i o n o f S t a n d a r d B620

Implementation
of
Fluid & Fab
Standard
SHOULD YOU
V O L U M E
REQUIRE MORE
1 ,
I S S U E
B620
1
M A R C H
2 0 1 5
AUTOGRAPHING OUR WORK WITH
EXCELLENCE
INFORMATION,
PLEASE CONTACT
US:
CONTACT PERSON:
Standard B620 Overview
This standard applies to tanks,
other than intermediate bulk
containers and tubes, used for
the transportation of dangerous
goods primarily by road. Learn
more about it below.
SHAWN BOYCE
PHONE :
(780) 808-6426
FAX :
(780) 875-1969
E-MAIL:
[email protected]
Why is Standard B620 required?
WEBSITE :
www.cllholdings.ca
5201- 67TH AVE.
LLOYDMINSTER, AB
T9V 3N6
CONTENTS
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
CSA Standard B620 specifies
requirements for highway,
portable, fiber reinforced plastic
and pressure/vacuum liquid
waste highway tanks for the
transportation of dangerous
goods. Industries from across
Canada were consulted and
formed a committee to evolve
this standard to what it is today.
Previous editions were published in 1987, 1998, 2003 and
the newest in 2009.
The standard is used mostly for
tanks/vessels that travel on
roadways but may include
those used on rail and marine. It
considers the design, construction, certification, assembly,
modification, repair, testing,
inspection and periodic retesting, identification and maintenance of these tanks. The Transportation of Dangerous Goods
(TDG) Acts and Regulations
apply the Standard B620 as well
as what is contained in their
acts and regulations. Did you
know that?
Any facility that is performing
inspections, manufacturing of,
modification, assembly, repair
or testing must register and
maintain a quality control
manual with Transport Canada.
This manual describes the
activities of the facility, what
they can do, not what they can’t
do. Our manual is very strong
in the areas of training and
safety of all personal and equipment they are working on. All
testing procedures are
contained in this manual and
followed accordingly.
What criteria is required for
each level of inspection and
how often are they required?
Periodic testing and inspection
are contained on tables 1 and 2.
Did you know that a hydrostatic or pneumatic test and
inspection is required if...
... the tank shows signs of dents
abrasions corroded or signs on
leakage?
...the tank was involved in an
accident that may have compromised the tank
...the tank hasn’t been used for
one year or more to transport
dangerous goods
...the tank has been modified
How do you compare
inspections done from one
facility to the next?
We offer inspection services
wherein we follow strict
policies and procedures for our
safety and our customers peace
of mind. Check out our
inspection services listed
below.
External (Visual) Inspection
includes, but not limited to,
checking for:
defect in welds, piping,
dents, distortion of shell or
heads
man hole covers are
operative
functioning of valves,
vents and emergency
devices
all flanged connections
including blanks have all
bolts and nuts and are
properly tightened
level gauges operating
properly
the specification plate and
other markings are legible
and all proper information is
stamped
all attachments and major
appurtenances are not
damaged or badly corroded
hoses for abrasion
self-closing relief valve for
corrosion or damage
full opening of rear head for
cuts, cracks or splits
(if the damage is more
than .5” in depth, it must be
replaced)
internal self-closing valve
and off-truck emergency
shutdown system
Note:
If tank is corroded, a Thickness
Test will be performed.
1
1
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
REQUIRE MORE
V O L U M E
INFORMATION,
1 ,
I S S U E
1
B620
M A R C H
2 0 1 5
AUTOGRAPHING OUR WORK WITH
EXCELLENCE
PLEASE CONTACT
US:
CONTACT PERSON:
SHAWN BOYCE
Internal (Visual) Inspection
includes, but not limited to,
checking for:
PHONE :
(780) 808-6426
checking tank shell, heads,
baffles for cracks, dents,
defective welds, loose fasteners, internal piping,
valves, etc.
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
primary shut-off for missing
or damaged parts (vacuum
unit)
5201-67TH AVE.
LLOYDMINSTER, AB
T9V 3N6
lining inspection, if required
Upper Coupler Inspections
Vac Unit (unit with pin
welded to sub-frame that is not
removable)
CONTENTS
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
tractor is unhook from unit
cleaned, king pin and subframe inspected for weld
defects, wear abrasions or
dents
Tanker Unit
sub-frame is unbolted from
frame cleaned if necessary;
same inspection as above is
performed; sub-frame replaced, nuts and bolts tightened to specification
Leakage Test
includes, but not limited to:
all product piping and
valves shall be in place and
operative
all relief valves set to below
test pressure removed and
opening capped or plugged
Hydrostatic test on any
tanks over MAWP of 5psi
Pneumatic test with the use
of soapy water on any tanks
MAWP of 5psi and below
80% of MAWP is held for
minimum of 5min
bench testing of relief valve
An External (Visual) Inspection is also done at this
interval.
Thickness Test
includes, but not limited to:
Test of thickness of tank
shell and head around openings and piping that show
signs of high stress or abrasion
Pressure Test (Hydrostatic)
relief valves are removed
and plugged or blocked. At
this interval, the relief valve
is sent out to a certified
valve company for inspection, cleaning, repair and
certification as required by
Standard B620. This information is kept on file linked
to the tank which is being
tested.
Pressure Test (Pneumatic)
applied to tanks with MAWP of
5psi or less
the procedure is similar to
the Hydrostatic Test but
compressed air is used.
Also non-destructive examination (NDE) that is required or if
there is any fault or defect that
is questionable, a second party
that is registered to do the required level of inspection will
be called in.
As required by the Standard
B620, a written report for each
inspection or test is dated and
signed by the tank inspector
and is provided to customer. A
copy is always kept on file as
required by Transport Canada
for auditing or reference purposes.
the tank is completely filled
with water and pressured to
the manufacturer’s test pressure and/or referencing a
chart contained in the Standard B620. This pressure is
held for 10min minimum.
The tank and all outlets are
checked for leaks during this
time.
2
2
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
REQUIRE MORE
V O L U M E
INFORMATION,
1 ,
I S S U E
1
B620
M A R C H
2 0 1 5
AUTOGRAPHING OUR WORK WITH
EXCELLENCE
PLEASE CONTACT
US:
CONTACT PERSON:
SHAWN BOYCE
What do you look for when
sourcing a Transport Canada
Registered Facility?
PHONE :
(780) 808-6426
You can use Transport Canada’s website. There you will
find:
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
5201-67TH AVENUE
LLOYDMINSTER, AB
T9V 3N6
Midwest Fluid & Fab,
A Division C.L.L Holdings Ltd.
Transport Canada
Facility Registration #: 25-0538
How long have we been doing
inspections?
Eleven Years
Is our staff well-trained and
understand our Quality
Program?
CONTENTS
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
Yes. Our QC Manager has 30
years of experience as a B Pressure Welder/Fabricator. He has
been involved in the program
since its inception and familiar
with the Standard B620.
Is safety being considered in the
work area?
We have our strict garaging
policy as well as an up-to-date
safety program. All personnel
working on your equipment
follow these strict procedures.
CONTACT US AND LET’S TALK
ABOUT YOUR
REQUIREMENTS.
What about repairs and
fabrication?
Yes, we may have an advantage
over others. We have a well
versed Parts Department. Our
Welding Department can
handle any B620 issues as well
as repairs or fabrication.
If you have other questions or
inquiries, do not hesitate to ask.
Our tank tester has one year
experience working on tanks/
vessels and is learning our procedures on testing and repairing
different tanks/vessels.
What about pricing for inspection services?
We have competitive pricing,
please stop by and inquire.
A LOCAL COMPANY GROWING TO
MEET YOUR NEEDS….
3
3
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
REQUIRE MORE
B620
INFORMATION,
PLEASE CONTACT
V O L U M E
US:
1 ,
I S S U E
1
M A R C H
2 0 1 5
Tank Testing & Marking
CONTACT PERSON:
SHAWN BOYCE
PHONE :
(780) 808-6426
Type
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
5201-67TH AVE.
LLOYDMINSTER, AB
T9V 3N6
CONTENTS
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
External
Internal
Lining
Leakage Test
Pressure,
Inspection
Inspection
Inspection
406/306
1 year
5 years
1 year
5 years
406/306 Crude
2.5 years
5 years
2.5 years
5 years
407/307
1 year
5 years
1 year
5 years
407 Vacuum with
6 months
5 years
1 year
2 years
412/312
1 year
5 years
1 year
5 years
412 Vacuum with
6 months
5 years
1 year
2 years
423
1 year
1 year
1 year
5 years
350
6 months
1 year
1 year
2 years
350 Crude
1 year
1 year
1 year
2 years
331
1 year
5 years
1 year
5 years
2 years chlorine
338
1 year
2 years chlorine
5 years
341
1 year
10 years (unless
alternative test-
11
1 year
10 years if it has a
51 Portable
2.5 years
5 years
56/57 Portable
2.5 years
60Portable
2 years
4-8-10-12 years
then every year
Types 1,2 & 3
25 years
2.5 years
Intermodal
UN31
5 years
Hydro, or
10 years
1 year
5 years
5 years
5 years
2.5 years
4-8-10-12 years
4-8-10-12 years
Then every year
5 years
Then every year
5 years
5 years
Intermediate Bulk
Container (slip
4
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
B620
REQUIRE MORE
INFORMATION,
PLEASE CONTACT
V O L U M E
1 ,
I S S U E
1
M A R C H
2 0 1 5
US:
AUTOGRAPHING OUR WORK WITH
EXCELLENCE
CONTACT PERSON:
SHAWN BOYCE
PHONE :
(780) 808-6426
FAX :
(780) 875-1969
E-MAIL:
[email protected]
Lined and unlined tanks in corrosive service must have an annual internal inspection. The lined tanks
must also have the lining checked at the same time interval. Unlined tankers in corrosive service must
have an annual internal inspection and a thickness test done every 2 years.
WEBSITE :
www.cllholdings.ca
All tanks with an upper coupler must have the tank checked for corrosion under the upper coupler every
5 years.
5201-67TH AVENUE
LLOYDMINSTER, AB
T9V 3N6
For additional information please click on the following link: http://www.transportation.alberta.ca/
CONTENTS
Each tank must be marked on the side near the metal identification plate or head end with
the following letters, as applicable, to show that the periodic test have been carried out. A
new tank requires the initial test information on the manufacturer’s plate only:
Letter
Test or Inspection
V
VISUAL (EXTERNAL) INSPECTION
I
INTERNAL INSPECTION
P
PRESSURE TEST
T
THICKNESS TEST
L
LINING INSPECTION
K
LEAK TEST
UC
UPPER COUPLER AREA INSPECTION
WF
WET FLUORESCENT MAGNETIC PARTICLE INSPECTION
C
FOR TC 341 TANKS ONLY IF A COLD VACUUM RETENTION TEST HAS BEEN CARRIED OUT INSTEAD OF AN
INTERNAL (ALTERNATIVE TESTING)
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
The date the test were carried out must also appear on the tank, for example (one possible
format:
02/09 V I K P 123
Highway & Portable Tank Specs
69
Shows that visual, internal, leak and pressure tests were carried out in February 2009. The digits
“123 “ represent the last three digits in the Transport Canada registration number of the test facility.
5
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
B620
REQUIRE MORE
INFORMATION,
PLEASE CONTACT
V O L U M E
1 ,
I S S U E
1
M A R C H
2 0 1 5
US:
Highway and Portable Tank Specifications
CONTACT PERSON:
SHAWN BOYCE
PHONE :
(780) 808-6426
TC331
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
5201-67TH AVENUE
LLOYDMINSTER, AB
T9V 3N6
Highway tank for liquefied compressed gases (e.g. LPG, NH3);
Steel or aluminum;
Design pressure shall be at least 690 kPa (100 psi) and not more than
3450 kPa (500 psi);
CONTENTS
Standard B620
Overview
1
Requirements
and Criteria
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
TC338
Insulated highway tank for gases as refrigerated liquids;
Supported welded inner vessel enclosed within a jacket;
Insulation between the inner vessel and jacket;
Insulation may be by vacuum;
Design pressure shall be at best 180 kPa (26 psi) and not more than
3450 kPa (500 psi);
6
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
B620
REQUIRE MORE
INFORMATION,
PLEASE CONTACT
V O L U M E
1 ,
I S S U E
1
M A R C H
2 0 1 5
US:
Highway and Portable Tank Specifications
CONTACT PERSON:
SHAWN BOYCE
TC341
PHONE :
(780) 808-6426
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
5201-67TH AVENUE
LLOYDMINSTER, AB
T9V 3N6
Insulated highway tank for non flammable gases as refrigerated liquids;
Pressure control valve set at 175 kPa (25.3 psi);
Supported inner vessel enclosed within a jacket;
Insulation between the inner vessel and jacket;
Insulation may be by vacuum;
CONTENTS
TC406
Standard B620
Overview
1
Requirements
and Criteria
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Highway tank for flammable liquids and low hazard chemicals (e.g. gasoline,
diesel);
Steel or aluminum shell or reinforced plastic;
Staff
Qualifications
3
MAWP between 18 and 28 kPa (2.65 and 4 psi);
If transporting crude, MAWP between 18 and 100 kPa (2.65 and 14.7 psi);
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
7
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
B620
REQUIRE MORE
INFORMATION,
PLEASE CONTACT
V O L U M E
1 ,
I S S U E
1
M A R C H
2 0 1 5
US:
Highway and Portable Tank Specifications
CONTACT PERSON:
SHAWN BOYCE
TC407
PHONE :
(780) 808-6426
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
5201-67TH AVENUE
LLOYDMINSTER, AB
T9V 3N6
Highway tank for toxic, corrosive and flammable liquids;
Circular cross-section;
MAWP of at least 172 kPa (25 psi);
Over 235 kPa (35 psi) or vacuum loaded, must be ASME;
May be vacuum loaded if external design pressure is at least 103 kPa (15 psi)
and internal design pressure is at least 173 kPa (25 psi);
Steel, aluminum or reinforced plastic;
CONTENTS
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
TC412
Highway tank for corrosive and some flammable liquids;
MAWP of at least 35 kPa (5 psi);
MAWP greater than 104 kPa (15 psi) shall be circular cross-section and
ASME certified;
Steel, aluminum or reinforced plastic;
May be vacuum loaded if external design pressure is at least 103 kPa (15
psi)
and internal design pressure is at least 173 kPa (25 psi);
8
Implementation
of
Fluid & Fab
Standard
SHOULD YOU
B620
REQUIRE MORE
INFORMATION,
PLEASE CONTACT
V O L U M E
1 ,
I S S U E
1
M A R C H
2 0 1 5
US:
Highway and Portable Tank Specifications
CONTACT PERSON:
SHAWN BOYCE
PHONE :
(780) 808-6426
TC423
FAX :
(780) 875-1969
E-MAIL:
[email protected]
WEBSITE :
www.cllholdings.ca
5201-67TH AVENUE
LLOYDMINSTER, AB
T9V 3N6
Highway tank for emulsion and water-gel explosives;
MAWP of at least 35 kPa (5 psi) but not more than 103 kPa (15 psi);
Steel or aluminum;
Hopper style configuration accommodated;
Insulated:
CONTENTS
Standard B620
Overview
1
Requirements
1
Inspection
Services
1
Inspection
Services Cont.
2
Company
Registration
3
Staff
Qualifications
3
Inspection
Interval Tables
45
Highway & Portable Tank Specs
69
9