Loading Battery HEARING AID HB-23PT HB-23P Instruction Manual 1. Remove the sealing on the positive side of battery (PR-48 or 13 zinc-air battery) before loading. The battery operates normally in about 1 minute after the sealing is removed. 2. Open the battery compartment lid. 3. Load a PR-48 or 13 battery into the battery compartment with correct polarity; the plus mark on the battery and the lid should be on the same side. 4. Close the battery compartment lid. 1 2 3 Positive 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan HOW TO USE YOUR FIRST HEARING AID Any hearing aid cannot return level of your hearing to normal or halt further hearing deterioration, but proper use of your hearing aid can help you hear what is going on around you and let you get more enjoyment of life. If this is your first hearing aid, you - like most new users - will probably be surprised at the loudness of the sounds, and after using it for a short while, you may even feel that it is too noisy. The following three tips are important in overcoming your concerns. 1) Read this manual and become familiar with the hearing aid's various mechanisms and how to use them correctly. 2) First, use your hearing aid in a quiet place and listen to quiet sounds and give yourself sufficient time to get accustomed to the sound of your hearing aid. 3) If any physical problems develop, consult your doctor. Mark of positive side Be sure to remove the battery when the hearing aid is not to be used for an extended period of time. Battery life: Approx. 177 hours (PR-48 or 13, for continuous use) Battery life will change depending on the operating condition. Putting on Hearing Aid 1. Hold the hearing aid as shown and put it on your ear. 2. Insert the earpiece into your ear. 1 2 INSIDE THE HEARING AID BOX Check the all items illustrated below are contained in the box. Earhook S (EH310000) TONE Case (HBBXB001) Joint B (GS96S050) HB-23PT/HB-23P Hearing aid Soft Earpiece MS (MS: GS300030) Instruction Manual (41622) Insert earpiece If the hook is small or large and does not fit, consult the dispenser. Precautions Additional Information (41353) Battery (13 or PR48) OPERATING INSTRUCTIONS Small Parts and Controls Wind screen Microphone *Tone Control Volume Control O-T-M Switch *MOP Control Battery Compartment TONE Earhook S : EH310000 M: EH320000 L : EH330000 Joint B (GS96S0020) Soft Earpiece S : GS300020 MS: GS300030 M : GS300040 Above illustration shows HB-23PT. HB-23P is not equipped with induction coil (T position of O-T-M switch), Tone switch and MOP control. The parts drawn on the right side of the above picture are consumables. Please ask your supplier to buy them. * Do not touch the control. Any adjustment should only be performed by your Audiologist or hearing aid dispenser. Good Large O-T-M Switch (HB-23PT) /O-M Switch (HB-23P) O: Power off Set to "O" when the hearing aid is not in use. T: Induction coil (telephone coil, HB-23PT only) Set to "T" when using the hearing aid to telephone or loop. O T M When the switch of the hearing aid is set to T, noise may be heard in the vicinity of electromagnetic fields, such as generated for example by electronically secured gates or similar. M: Microphone Set to "M" to hear sounds through the microphone. When taking off the hearing aid, set the switch to "O". If not, acoustic feedback may result. Volume Control When you remove the hearing aid from your ear Adjust the sound volume to the most comfortable level with the volume control. The best position of the control will depend upon the distance and voice of the person with whom you are talking; readjustment may be necessary. When using the hearing aid for the first time, set the control for a comfortable level, then reduce the volume slightly. Set the switch to "O" to power off and remove the hearing aid from your ear. When removing the hearing aid with the switch setting "M" or "T", acoustic feedback (high-pitched sounds) might be heard. TECHNICAL DATA Increase Reduce TECHNICAL DATA (According to ANSI Standard S3.22 1987) 125 dB Reference Test Frequency 1600 Hz HFA-SSPL90 119 dB Full-on Acoustic Gain 46 dB Reference Test Gain 200 Hz to 6000 Hz Equivalent Input Noise On Set to "O" 54 dB 500 Hz 121 dB Peak 131 dB Equivalent Input Noise Level 27 dB Off 127 dB OSPL90 42 dB Frequency Range T M (According to IEC Standard Pub. 60118 1983) Maximum SSPL90 HFA-full-on Gain O 26 dB Total Harmonic Distortion 800 Hz: 8%, 1600 Hz: 2% Total Harmonic Distortion 500 Hz: 28%, 800 Hz: 22%, 1600 Hz: 8% Induction Coil Sensitivity 84 dB at 10 mA/m (HB-23PT only) Induction Coil Sensitivity Range of Volume Control Range of Volume Control 40 dB 79 dB at 1 mA/m (HB-23PT only) 40 dB Input Switch O-T-M (HB-23PT), O-M (HB-23P) Input Switch O-T-M (HB-23PT), O-M (HB-23P) Output Limiting Control MOP Control, range 10 dB (HB-23PT only) Output Limiting Control MOP Control, range 10 dB (HB-23PT only) Tone Switch Low Frequency Reduction (HB-23PT only) Tone Switch Low Frequency Reduction (HB-23PT only) Battery Type, Current, Life 13, 1.3 mA, approx. 177 h Battery Type, Current, Life PR-48, 1.3 mA, approx. 177 h Receiver, Microphone Magnetic, Electret Condenser Earphone, Microphone Magnetic, Electret Condenser Dimensions and Weight 3.6 × 1.3 × 0.88 cm, 4.2 g (excluding battery) Dimensions and Weight 3.6 × 1.3 × 0.88 cm, 4.2 g (excluding battery) (Typical value) 110 100 TONE: N 90 TONE: H 80 100 200 500 1000 2000 5000 60 50 40 30 130 200 500 1000 2000 5000 10000 500 1000 2000 90 200 5000 10000 Frequency (Hz) 500 1000 2000 5000 60 50 40 30 100 10000 200 500 1000 2000 5000 10000 Frequency (Hz) 110 1600 2500 Input 10 mA/m 0dB=20µPa 100 90 80 70 60 100 OSPL 90 frequency response and effect of MOP control (HB-23PT) 140 Output SPL (dB) 110 MOP 0 -4 100 -8 90 -10 200 TONE: N Input SPL 60 dB (0dB=20µPa) 70 Frequency (Hz) Induction coil input characteristics (HB-23PT only) Output SPL (dB) Output SPL (dB) 120 80 100 100 1600 2500 80 Response of HB-23P is equivalent to curve with TONE N. 1600 2500 Input SPL 90 dB 0dB=20µPa 110 80 100 Response of HB-23P is equivalent to curve with TONE N. 130 120 Frequency (Hz) Frequency (Hz) SSPL90 frequency response and effect of MOP control (HB-23PT) 1600 2500 Input SPL 60 dB 0dB=20µPa TONE: H 20 100 10000 Input SPL 60 dB (0dB=20µPa) Full-on acoustic gain frequency response 200 500 1000 2000 5000 10000 Frequency (Hz) Response of HB-23P is equivalent to curve with MOP 0. Note: (1) Production number (serial number) is indicated inside the battery compartment. (2) Production year is imprinted at the bottom of the unit. (3) Manufacturer's name is imprinted at the rear side of the unit. 1600 2500 Input SPL 90 dB 0dB=20µPa 130 120 MOP 0 -4 -8 100 -10 110 90 100 200 Induction coil input characteristics (HB-23PT only) 120 Output SPL (dB) 120 1600 2500 70 Basic frequency response and effect of Tone switch (HB-23PT) Acoustic Gain (dB) 1600 2500 Input SPL 60 dB 0dB=20µPa Acoustic Gain (dB) Output SPL (dB) 130 Full-on gain frequency response Output SPL (dB) Basic frequency response and effect of Tone switch (HB-23PT) (Typical value) 500 1000 2000 5000 10000 1600 2500 Input 10 mA/m 0dB=20µPa 110 100 90 80 70 100 200 500 Frequency (Hz) 1000 2000 5000 10000 Frequency (Hz) Response of HB-23P is equivalent to curve with MOP 0. EC REP RION CO., LTD. 3-20-41 Higashimotomachi Kokubunji, Tokyo 185-8533 Japan. RION CO., LTD. Europe Representative Office Schaepmanlaan 66 NL-4623 XZ Bergen op Zoom THE NETHERLANDS 2008 No. 41622 08-01
© Copyright 2024