CYLINDRO III Mounting Instructions WARNING: disconnect main power at the source prior to installation! Only qualified electricians should install Delray Lighting products. Standard Surface Mount Canopy Mount cable gripper with #8 screw, or mount directly to 1/4 20 stud. Secure lamp cord in canopy with strain relief 10” dia. Use cable tie to join cord to cable NOTE: use 1/4 – 20 toggle bolt and fender washer (or equivalent) to cover the hole. 2.5” Mount Driver Canopy to J-Box 3 Mounting Points: 6803 – on 31.625” diameter, 27.39” centers 6804 – on 43.625” diameter, 37.8” centers 6805 – on 55.375” diameter, 48” centers *Max. Wiring Distance (at full load) Wire Size (AWG) Distance (ft.) 18 16 14 12 10 18 29 46 71 120 NOTE: multiple drivers must be mounted no less than 4 inches apart side-by-side, and 1 inch apart end-to-end, to avoid overheating. SLRD Option Remote Driver Remote driver housing must remain accessible. Use bar hangers to mount in ceiling. Bottom base threaded for 1/4 -20. Mud ring or octagonal box, by others. See Chart* 0000000000000 00 000000000000000 MAR 2015 Flexible conduit and wire, by others w w w. del r a yl i ghti ng. c o m