Polymer Guide

Dentium Instruments
for Total Solution
Catalog & Manual
Index
Surgical Guide
Polymer Guide
Implant Guide
04
06
Sinus Instruments
DASK
Osteotome Kit
Sinus Elevator
11
16
17
GBR Instruments
RS Kit
GBR System
Harvest Drill
19
24
35
Others
Help Kit
Temporary Shell
Dental Maintenance Tips
38
45
48
Surgical Guide
Polymer Guide
Implant Guide
Dentium Instruments
Polymer Guide
Polymer Guide
Thermoplastic Surgical Template for Dental Implant Placement
• Fabricate precise surgical template in just minutes using hot water
• Disposable material to promote control of infection and contamination
• Titanium sleeve is compatible with Dentium Guide and Final Drills
Fully compatible with Dentium Drill System
Thermoplastic surgical template
Fabricate an accurate surgical template
in just minutes, greatly reducing
the lab and chairside time.
4
Suitable template shape
Improved infection/contamination control
Polymer Guide is designed to maximize contact
area over the adjacent teeth while allowing
substantial field of view during implant surgery.
To ensure infection/contamination-free surgery
every time, the Polymer Guides are made to be
disposable.
Drill a hole in the stone model
Insert the Guide Pin
Remove the Guide Pin
Position the Polymer Guide intra-orally
for drilling
Soak the Polymer Guide in hot water
above 65°C to soften up the material for
easy molding.
Apply of Polymer Guide
on stone model
Dentium Instruments
Polymer Guide
PGSSK
PGSCK
Single Standard (5ea)
Cantilever Multi-Ready (5ea)
22
22
35
45
2.5 T
2.5 T
* Average mesiodistal
width of a tooth
7
* 1 fixed sleeve +
3 additional Sleeve holes
[ Unit: mm, Scale 1 : 1 / mm ]
T
2.5
Art. No.
XSG 34 35 S
T
2.5
Art. No.
XSG 34 45 C
Stone Drill
XGD 23 60
(1ea)
Guide Pin
XGP 34 23 S
(5ea)
Guide Drill Brushing (First)
XPGB 19 26
(1ea)
Guide Drill Brushing (Second)
XPGB 26 34
(1ea)
Additional Metal Sleeve
(for Cantilever Multi-Ready)
XPGS 34 25 A
(5ea)
5
Dentium Instruments
Implant Guide
Implant Guide
Surgical guide utilizing silicon spacer and unique parallel pin
• The tripod parallel pin is designed to take into consideration the mesiodistal width and drilling position in the
edentulous area
• Parallel pins and Spacers are configured based on the average width of a tooth
Assist in the implant positioning as well as
determining the width and the position of
the prosthetic components
The Guide Drill holes on the Tripod
Parallel Pin help in prepping the
osteotomy in the correct orientation
The three legs of the Tripod Parallel Pin
are of different lengths to accommodate
varying widths of prosthesis for multiple
unit bridges
6
Spacer + Guide Drill
Ellipse Parallel Pin
Final prosthesis
Spacer + Guide Drill
Ellipse Parallel Pin + Tripod Parallel Pin
Final prosthesis
Dentium Instruments
Implant Guide
GUIDE
Ø2.2
Ø6.0
Ø7.0
Ø8.0
SPACER
Ø9.0
Ø10.0
15
14
16
4.0 / 5.0
6.0 / 7.0
8.0 / 9.0
10.0 / 11.0
18
17
19
ELLIPSE PARALLEL PIN
ISGK
Kit Contents
Guide Drill
XLD 22 35S
10
XLDSP 60S
XLDSP 70S
XLDSP 80S
XLDSP 90S
XLDSP 10S
10
9
8
8
6
7
4
XPP 2226 50G
XPP 2226 70G
XPP 2226 90G
XPP 2226 11G
14
19
16
XPP 2226 1416G
18
Tripod Parallel Pins
15
Ellipse Parallel Pins (x2)
6
17
Spacers
XPP 2226 1719G
7
Dentium Instruments
Implant Guide
Spacers
Diameter
6
7
8
9
10
6
7
8
9
10
6.0
Art. No.
Ø6
XLDSP 60S
Ø7
XLDSP 70S
Ø8
XLDSP 80S
Ø9
XLDSP 90S
Ø 10
XLDSP 10S
Ellipse Parallel Pins
4
6
11
9
7
5
8
10
10
8
6
4
8
Diameter
Art. No.
Ø4/Ø5
XPP 2226 50G
Ø6/Ø7
XPP 2226 70G
Ø8/Ø9
XPP 2226 90G
Ø 10 / Ø 11
XPP 2226 11G
2.5
8
Tripod Parallel Pins
2
Width
Ø 2.3
14
15
18
17
19
16
8
2.5
8
8
Art. No.
14 / 15 / 16
XPP 2226 1416G
17 / 18 / 19
XPP 2226 1719G
Manual
Dentium Instruments
Implant Guide
Single Case
8
8
Incision
Guide Drill
Combination of Guide Drill and
Spacer
Ellipse Parallel Pin
Final Drill
Ø 3.6 ~ Ø 5.0
Countersink
Fixture placement with
Healing Abutment
SuperLine FX5010
Dual Abutment Connection
Final prosthesis
Ø 5.0
Multiple Case
19
18
17
Guide Drill
Combination of Guide Drill and
Spacer
Guide Drill
Application of Tripod and Ellipse Parallel Pin
Final Drilling
Fixture placement with
Healing Abutment
Ø 3.0 ~ Ø 5.0
Dual Abutment connection
Final prosthesis
NR Line
NFX3611S / NFX4311S / NFX5011S
9
Dentium Instruments
Sinus Instruments
DASK
Osteotome Kit
Sinus Elevator
10
Dentium Instruments
DASK
Dentium Advanced Sinus Kit (DASK)
• Simple & easy access to sinus cavity
• Broad exposure of bony walls with special instruments
DASK Drills
XRT332035
Ø3.3
Type
DASK Drill #
REF
DASK Drill # 1
XRT 332035
DASK Drill # 2
XRT 372035
DASK Drill # 3
XED 331035D
DASK Drill # 4
XRT 064025
DASK Drill # 5
XRT 084025
DASK Drill v# 6
XRT 083025
12 10 8 6 4 2 0
Ø3.7
XRT372035
12 10 8 6 4 2 0
XED331035D
Ø1.6
12 10 8 6 4
Crestal
Approach
Ø3.3
10
Lateral
Approach
XRT064025
Ø6.0
Ø4.0
* DASK Drill #1~5 : Drill speed 800 to 1,200 rpm, 30~45N∙cm with internal irrigation
DASK Drill #6 : Drill speed 800 to 1,200 rpm, 30~45N∙cm with external irrigation
XRT084025
Ø8.0
XRT083025
Ø6.6
Ø8.0
Ø1.5 Ø1.5
[ Unit: mm, Scale 1 : 1.2 / mm ]
Stoppers
| for XRT332035, XRT372035, XED331035D
XFDST08
XFDST06
10.6
Ø5.14
[ Unit: mm, Scale 1 : 1 / mm]
XFDST04
12.6
Ø5.14
XFDST02
14.6
Ø5.14
16.6
Drilling Depth
L
REF
08
10.6
XFDST 08
06
12.6
XFDST 06
04
14.6
XFDST 04
02
16.6
XFDST 02
Ø5.14
11
Dentium Instruments
DASK
Sinus Bur Kit
SDK
Sinus Elevation Instruments
REF
XSE1L
REF
XSE2L
REF
XSE3L
REF
XSE4L
[ Scale 1 : 0.68 / mm ]
Drills for Crestal Approach
DASK Drill #1
XRT332035
DASK Drill #2
XRT372035
[800~1,200 rpm]
The distance from the alveolar crest to the sinus floor should
be measured on x-rays prior to surgery. Site preparation is
performed with final drills in sequence up to 1mm short of the
sinus floor. Then DASK Drill #1 or #2 is used and the sinus floor
is carefully approached with light apical pressure. When you
feel the yielding of the sinus floor, remove the drill. Or, partial
preparations with DASK Drill #1 or #2 and up-fracture with
osteotomes can be performed.
* The internal irrigation not only provides a cooling effect, but also adds hydraulic
pressure to slightly lift the sinus membrane during drilling.
12
DASK Drill #3
XED331035D
[800~1,200 rpm]
When the sinus cavity is accessed, DASK Drill #3 is introduced
and a much broader detachment from the sinus floor can be
facilitated horizontally with hydraulic pressure thanks to the
internal irrigation hole.
DASK Drill #3 can also be used for a lateral approach surgery.
Dentium Instruments
DASK
Drills for Lateral Approach
DASK Drill #4
XRT064025
DASK Drill #5
XRT084025
DASK Drill #6
XST083025
[800~1,200 rpm]
To make a lateral window through the antrostomy (thin-out)
approach.
* DASK Drill #4 or #5 is used to prepare a lateral sinus window using light
pressure and rotating stokes.
The DASK Drill #4 or #5 is designed to minimize the risk of sinus membrane
perforation.
[800~1,200 rpm]
To make a lateral window through the wall-off technique.
* DASK Drill #6 is used to cut and detach a bony island like a trephine bur from
the lateral wall.
Uncontrolled overdrilling may lead to sinus perforation and possible damage
to the membrane.
External irrigation is necessary when drilling.
DASK Maintenance
Sterilization and Instrument Care Procedures
• Please follow for legal regulations, as well as hygienic
guidelines to prevent contamination and infection.
• Please remember that you are responsible for the
maintenance and sterility of your medical/dental
products/device.
1. All instruments, immediately after use, must be
presoaked for a few minutes in a germicidal bath
to loosen and prevent debris from attaching to
instruments. Do not soak overnight.
2. Scrub with a soft brush to remove any debris.
• It is important to use and follow, proper cleaning,
disinfection and sterilization procedures.
3. For internal irrigation drills, use a reamer or small
gauge needle to internally cleanout the drills.
• It is also important to follow the manufacturer’s
recommendation on use of drills.
4. Before using an ultrasonic cleaner, wrap drills in a 2 x 2 gauze to prevent rubbing against each other.
• Please keep a log as to how many times the drills were
used.
5. Rinse thoroughly with warm water.
• Drill usage is determined by surgical site not per
patient. Bone density and usage determine the life of
the drills­­­­­­.
• Drills should be considered for replacement after
approximately 15- 20 uses based on bone density.
Check drills frequently for wear.
6. Clean all instrument trays with a germicidal cleaner
prior to replacing instruments in kit.
7. Dry completely and place back into kit.
8. Always check for damage or corrosion after rinsing
and drying.
9. Seal the tray in a sterilization pouch.
10. Sterilize using a steam autoclave in 121°C/250F for 30
minutes or refer to manufacturer’­­s recommendations.
11. Store in a dry area at room temperature.
13
Manual
Dentium Instruments
DASK
Crestal Approach (Sinus Lifting)
14
After Ø3.8 Final drilling, eliminate the
residual bone (1mm) using a DASK Drill #1 or
#2 (in hard bone) until you feel a slight drop.
Detach sinus membrane using the domeshape sinus curette.
Detaching the sinus membrane to create
adequate space for graft material.
Fill the sinus cavity with [OSTEON™ Lifting]
graft material.
Fill and distribute OSTEON™ graft material
evenly throughout the achieved space.
Placement of implant into the osteotomy
Manual
Dentium Instruments
DASK
Lateral Approach (Sinus Elevation)
Wall-off Technique
Detach sinus membrane using the domeshape sinus curette.
DASK Drill #6 is used to cut a round bony island from the lateral wall like a trephine
bur. Start to drill at a desired location and proceed until you see the shadow of the
sinus membrane. Then, separate and lift the bony island up from the neighboring
wall with a molt curette or a periosteal elevator. The bony island is repositioned back
in its original position after bone augmentation.
The first laser mark is 1.5mm and the second is
3.0mm. Overdrilling can cause sinus perforation
and possible damage to the membrane.
Elevate the sinus membrane to create
adequate space for graft material.
Thin-out Technique
Elevate the sinus membrane to create
adequate space for graft material.
Fill the obtained space with [OSTEON™
Sinus] graft material.
Thin down the lateral wall with DASK Drill #4 or #5 at a 45 degree angle to reach
the Schneiderian Membrane.
Move the DASK Drill #4 or #5 mesiodistally
with a gentle pressure until you get the
desired shape and size of the window for bone
augmentation.
The bony island can be repositioned
after bone augmentation. Implant placed
(SuperLine).
15
Dentium Instruments
Osteotome Kit
Osteotome Kit
• Osteotomes compress the bone laterally, providing denser bony interface rather than removing valuable bone from
the surgical site.
Osteotomes
| Final drill type
XOF 20 A1
ØB
ØA
XOF 34 A1
XOF 38 A1
Type A
Type
XOF 43 A1
XOFK
XOF 48 A1
A
(Convex)
[ Unit: mm, Scale 1 : 0.4 / mm]
XOFBK
B
(Concave)
16
Type B
(Convex)
(Concave)
Art No
ØA
ØB
XOFK 20 A1
Ø1.7
Ø2.8
XOFK 34 A1
Ø2.3
Ø2.8
XOFK 38 A1
Ø2.7
Ø3.2
XOFK 43 A1
Ø2.8
Ø3.8
XOFK 48 A1
Ø3.0
Ø4.3
XOFK 20 B1
Ø1.7
Ø2.8
XOFK 34 B1
Ø2.3
Ø2.8
XOFK 38 B1
Ø2.7
Ø3.2
XOFK 43 B1
Ø2.8
Ø3.8
XOFK 48 B1
Ø3.0
Ø4.3
Dentium Instruments
Sinus Elevator
Sinus Elevator
• Makes the sinus lift easy and drastically reduce the possibility of membrane perforation.
• Balloon expansion of 0.5cc saline equals 6mm of membrane elevation.
Ø3.70
Type
6.0, 1.0 X 6-lines
Art. No.
Including Syringe
GSB38
Balloon Only
GSB38B
Balloon inflation size(mm)
Injection Volume(cc)
6.0~6.5mm
4.0mm
0.5cc injection = Ø 6mm~6.5mm
Expand the balloon progressively.
Elevate the sinus membrane through
the balloon inflation.
Detach the sinus membrane to create
adequate space for graft material.
Carefully insert the Sinus Elevator into the
osteotomy.
Use [OSTEONTM Lifting] graft material
to fill the sinus cavity.
Placement of implant in the osteotomy.
17
Dentium Instruments
GBR Instruments
RS Kit
GBR System
Harvest Drill
18
Dentium Instruments
RS Kit
Ridge Spreader (RS) Kit
•
•
•
•
Allows the achievement of space for implantation through the spreading of the bone with chisel and without drilling
There are three types of Ridge Spreaders to create space up to Ø4.5
Convenient surgeries due to the compatibility with hand-piece and ratchet
Easy-to-use kit component
19
Dentium Instruments
RS Kit
XRSK
Kit contents
Bone Chisel
XBC305013
Ratchet
XRCA1
Ridge Spreader Drills
RS142435
RS203235
RS263635
20
Round Bur
RS263635
Ratchet Adapter
XRA3917
Mini Saw
XDS8025
Dentium Instruments
RS Kit
Bone Chisel
Art. No.
XBC305013
Art. No.
XRCA1
Ratchet
[ Unit: mm, Scale 1 : 0.6 / mm ]
Ridge Spreader Drills
Ø2.4
Ø1.4
35
Ø3.2
Ø2.0
35
Ø3.6
Diameter
L
Art. No.
Ø1.4 / Ø2.4
35
RS142435
Ø2.0 / Ø3.2
35
RS203235
Ø2.6 / Ø3.6
35
RS263635
Diameter
L
Art. No.
Ø4.0
35
XRB4035
Ø2.6
35
Round Bur
Ø4.0
35
Ratchet Adapter
Art. No.
XRA3917
17
Mini Saw
Ø8.0
Diameter
L
Art. No.
Ø8.0
25
XDS8025
25
[ Unit: mm, Scale 1 : 1 / mm ]
21
Manual
Dentium Instruments
RS Kit
RS Kit + NR Line + OSTEON™ II + Collagen Membrane
Incision
Decortification
Expansion with Bone Chisel
Expansion with Ridge Spreader (20~60rpm / 30~45 N∙cm) - Expanding alveolar bone ridge to make space for fixture
Fixture placement
NR Line 3609W
22
Cover Screw connection
Application of graft material
OSTEON™ ll
Manual
Dentium Instruments
Barrier membrane application
Collagen Membrane
Suture
Dual Abutment connection
Final prosthesis
RS Kit
Healing Abutment connection
23
Dentium Instruments
GBR System
Guided Bone Regeneration (GBR) System
Guided Bone Regeneration
• Allows the implantation of the GBR Technique with greater convenience
• Multi-function membrane screw for membrane and/or abutment/plate fixation
• Both GBR Abutment and Healing Abutment may be used with corresponding Plates and Screws
GBR Plates
• Supports membrane to hold up the graft material at desired volume
• Easy to bend and cut
• May overlap up to 3 plates with each abutment
Membrane Screws
• Multi-function membrane screws for membrane fixation and/or abutment/plate fixation
Membrane Pins
• Membrane pins for membrane fixation and/or plate fixation
GBR Plates
Straight
Tripod-Groove
Mandibular Total Osteotomy
Matrix
GBR Abutment Technique
24
Healing Abutment Technique
Dentium Instruments
GBR System
GBR Abutment Technique
Healing Abutment Technique
GBR Abutment
Ø3.5
Healing Abutment
Ø4.0 - Ø9.5
18
18
3.0
Top
4.5
Top
0.3
Side
0.3
Side
28
28
3.0
Top
4.5
Top
0.3
Side
0.3
Side
21
30.5
5.0
32.7
* The tripod-Groove
Plates can be cut in
desired length and
be used like a Straight
Plate
3.0
4.5
44
37
2.5
Ø 1.5
Ø 1.5
10.0
8.0
6.0
4.0
2.5
Ø 1.5
Ø 1.5
Ø 1.5
Ø 1.5
Ø 1.5
Ø 1.5
10.0
8.0
6.0
4.0
Ø 1.5
Ø 1.5
25
Dentium Instruments
GBR System
Mandibular Total Osteotomy Technique
A/H
4.0
6.0
8.0
5.5
3.7
A/H
2.5
Ø 1.5
Ø 1.5
Ø 1.5
10.0
8.0
6.0
4.0
Ø 1.5
Ø 1.5
[ Unit: mm ]
GBR Mandibular Total Osteotomy
26
Dentium Instruments
GBR System
GBR Products
GBR Abutment
G/H
Art. No.
2.0
GAB 35 20
G/H 2.0
Delivery Holder
* Compatible with the SuperLine Fixtures.
Compatible with Tightening Tool: Screw Abutment Hex (3.2 hex).
Use no more than 10N∙cm of torque when tightening the GBR Abutment to the fixture.
Ø 3.5
2.0
GAB3520 and
FX4510SW
[ Scale 1 : 1.5 / mm ]
Healing Abutment
Ø4.5
H 5.0
Ø 4.5
G/H 3.0
5.0
G/H3.0
HAB453050L
and FX4510SW
Diameter Ø4.0
Diameter Ø4.5
G/H
H
Art. No.
G/H
H
Art. No.
2.0
2.0
HAB 40 20 20 L
2.0
2.0
HAB 45 20 20 L
2.0
3.5
HAB 40 20 35 L
2.0
3.5
HAB 45 20 35 L
3.0
5.0
HAB 40 30 50 L
3.0
5.0
HAB 45 30 50 L
4.0
7.0
HAB 40 40 70 L
4.0
7.0
HAB 45 40 70 L
Diameter Ø6.5
Diameter Ø7.5 / 8.5 / 9.5
G/H
H
Art. No.
G/H
H
Art. No.
2.0
2.0
HAB 65 20 20 L
3.0
5.0
HAB 75 30 50 L
2.0
3.5
HAB 65 20 35 L
3.0
5.0
HAB 85 30 50 L
3.0
5.0
HAB 65 30 50 L
3.0
5.0
HAB 95 30 50 L
4.0
7.0
HAB 65 40 70 L
* Compatible with the SuperLine Fixtures.
Use no more than 10N∙cm of torque when tightening the Healing Abutment to the fixture.
Single use only.
27
Dentium Instruments
GBR System
GBR Plates
Straight
18
18
3.0
Top
4.5
Top
0.3
Side
0.3
Side
28
28
3.0
Top
0.3
Side
4.5
Top
0.3
Side
[ Scale 1 : 1.5 / mm ]
Type
Straight
L
T
Art. No.
18
0.3
GBP 18 04 S
28
0.3
GBP 28 06 S
Type
Straight
L
T
Art. No.
18
0.3
GBP 18 04 SH
28
0.3
GBP 28 06 SH
Tripod-Groove
21
5.0
32.7
30.5
* The tripod-Groove
Plates can be cut in
desired length and
be used like a Straight
Plate
3.0
4.5
[ Scale 1 : 1 / mm ]
Type
L
T
Tripod-Groove
21
0.3
Art. No.
GBP 21 13 T
Type
L
T
Tripod-Groove
21
0.3
Art. No.
GBP 21 13 TH
MTO
Matrix
44
A/H
4.0
6.0
8.0
5.5
3.7
37
[ Scale 1 : 1 / mm ]
28
A/H
[ Scale 1 : 1.5 / mm ]
Type
L
T
Matrix
44
0.3
Art. No.
GBP 44 99 T
Augmentation Height (A/H)
Art. No.
4.0
GBP 40 37 M
6.0
GBP 60 37 M
8.0
GBP 80 37 M
Dentium Instruments
GBR System
Membrane Screws
4.0
2.5
Ø 1.5
Ø 1.5
10.0
8.0
6.0
Ø 3.8
4.0
2.5
Ø 1.5
Ø 1.5
Ø 1.5
Ø 1.5
Ø 1.5
Ø 1.5
10.0
8.0
6.0
Ø 1.5
Ø 1.5
[ Scale 1 : 1.5 / mm ]
L
Art. No.
L
Art. No.
2.5
GSC 15 02
2.5
GSC 15 02H
4.0
GSC 15 04
4.0
GSC 15 04H
6.0
GSC 15 06
6.0
GSC 15 06H
8.0
GSC 15 08
8.0
GSC 15 08H
10.0
GSC 15 10
10.0
GSC 15 10H
can be used with GBR Abutment
Screw Case | 10 screws per case
Membrane Pins
Ø 3.0
2.75
Ø 0.5
Membrane Pin
with insertion tool
[ Scale 1 : 2 / mm ]
L
2.75
Art. No.
GMT 2525 C
Pin Case | 10 pins per case
29
Dentium Instruments
GBR System
Instruments
GBRK
Kit Contents
30
Screw Drill
GMD 1228
Hand-piece Insertion Tool Ratchet
GST 26 H
Hand-piece Adapter
XMAA1
Torque Wrench Adapter
XMA 21 W
Screw / Membrane Pin Insertion Tool
GST 85
Dentium Instruments
GBR System
Adapters | for Screw, Ball and GBR Abutments
20
Type
Art. No.
Hand-piece
XMAA1
Torque Wrench
21
XMA 21W
Screw Drill
Diameter
10.0
Ø 1.2
Art. No.
Ø1.2
GMD 1228
[ Unit: mm, Scale 1 : 1.5 / mm ]
Compatible with Guide Drill Stopper
4.6
6.6
XLDST14
8.0
8.6
XLDST12
10.6
XLDST10
XLDST08
Assemble with Guide Drill Stopper
6.0
4.0
2.0
Ø 1.2
8.5
6.5
XLDST14
4.5
XLDST12
2.5
XFDST10
XFDST08
Screw / Membrane Pin Insertion Tools
GST 26H
Art. No.
GST26H
GST 56
GST56
GST 85
GST85
COD
COD
[ Unit: mm, Scale 1 : 0.7 / mm ]
31
Dentium Instruments
Manual
GBR System
Case 1 OSTEON™ II Collagen + GBR Plate (Straight)
GBR Abutment connection
SuperLine : FX4510SE
Application of graft material
OSTEON™ II
Fixation of Plate
0.3mm thickness /18.0mm length plate
Fixation of Plate
Plate with Membrane Screw
32
Fixation of Plate
Plate with Membrane Screw
Fixation of Collagen Membrane
Membrane with pin
Suture
Dentium Instruments
Manual
GBR System
Case 2 OSTEON™ II Collagen + GBR Plate (Tripod -Groove)
GBR Abutment connection
SuperLine : FX4510SE
Application of graft material
OSTEON™ II
Fixation of Plate
0.3mm thickness / Cut-out Tripod-Groove plate
Fixation of Plate
Plate with Membrane Screw
Fixation of Plate
Plate with Membrane screw
Fixation of Collagen Membrane
Membrane with Screw
Suture
33
Manual
Dentium Instruments
GBR System
Case 3 OSTEON™ II + GBR Plate (Matrix)
GBR Abutment connection
SuperLine : FX4510SE
Application of graft material
OSTEON™ II
Plate placement
0.3mm thickness / Cut-out Matrix plate
Fixation of Plate
Plate with Membrane Screw
Suture
34
Collagen Membrane placement
Dentium Instruments
Harvest Drill
Harvest Drill
Collect autogenous bone and prep osteotomy simultaneously and effectively using the specially designed drills,
the Harvest Drills.
• Sharp, pointed tip to prevent drill chattering for precise drilling.
• Drill stoppers applicable to control the depth of the drilling for safe and efficient bone harvesting, especially in the
buccal side of the ridge.
• Recommended drill speed of less than 100 rpm / 50N∙cm helps preserve the vital autogenous bone.
• Excellent clinical results may be achieved when harvested autogenous bone is combined with Osteon™ II.
Harvest Drills
8 101214
Ø 2.9
35
Ø 3.35
35
Ø 3.85
Diameter
L
Art. No.
Ø2.9
35
XFH 34 35
Ø3.35
35
XFH 38 35
Ø3.85
35
XFH 4335
Ø4.4
35
XFH 48 35
35
Ø 4.4
35
Harvest Drill Stopper
Ø 6.14
L
Art. No.
15.9
XFHST04
15.9
4.0
First Guide Drill
Ø 2.2
35
Diameter
L
Art. No.
Ø2.2
35
XFH 22 35
Diameter
L
Art. No.
Ø2.6
35
XFH 26 35
Second Guide Drill
Ø 2.6
35
[ Unit: mm, Scale 1 : 1 / mm ]
* Bone collection in the buccal side of ridge : 50~200rpm / 30~50N·cm
35
Dentium Instruments
Harvest Drill
Final Drill
[2]
1
2
1 - First Guide Drill
2 ~ 4 - Harvest Drill
1000 rpm / 30~45N·cm with irrigation
30~100 rpm / 30~50N·cm without irrigation
4
3
Harvest Drill
(Final Drill)
First
Guide Drill
Second
Guide Drill
Ø 2.2
Ø 2.6
XLD 2235
XLD 2635
3.4
3.8
4.3
4.8
Ø 2.9
Ø 3.35
Ø 3.85
Ø 4.4
XFH 3435
XFH 3835
XFH 4335
* During the 4.3/4.8 fixture insertion into the bone density of D3~D4, the 3.35/3.85 harvest drilling process can be skipped.
36
XFH 4835
Dentium Instruments
Others
Help Kit
Temporary Shell
Dental Maintenance Tips
37
Dentium Instruments
Help Kit
Help Kit
• Easy solution for critical problems which may occur in the prosthetics process
• 5 tools in 1 kit (Screw Remover / Abutment Hex Remover / Screw Tap Repair Fixture Remover /
Cover & Abutment Screw Remover)
• Compatible with most dental implant products now available on the global market
• Heavy duty with robust design and proven materials
XIH
Screw Remover
33
25
L
Art. No.
25
XRF S2S
35
XRF S2
L
Art. No.
20
XRHR 20
25
XRHR 25
Abutment Hex Remover
20
38
25
Dentium Instruments
Help Kit
Screw Tap Repair
Type
11°
8°
25
Art. No.
Tap
XRSTR
11° Guide
XRSG11
8 ° Guide
XRSG8
Type
Art. No.
Fixture Remover
11°
8°
XRFRTF
25
25
25
Remover
XRFRT
XRFRTO
Wrench
XRFRW
L
Art. No.
25
XRRHD
25
Cover & Abutment Screw Remover
25
39
Dentium Instruments
Manual
Help Kit
Screw Remover
Application
To remove the remaining screw when the abutment screw is broken inside the fixture.
Advantage
Easy to remove the broken screw, as well as protect the internal threads of the fixture from being damaged.
Usage
1.Set the torque of the implant motor to 30~50 rpm in a CCW (counterclockwise) direction.
2.Assemble the tool with the hand-piece.
3.Run the motor while keeping the tip of the tool appropriately contacted with the broken screw until successfully
removed.
*Caution: Do not overload the tool with pressure; apply moderate pressure.
1
2
Dual Abutment
Use the friction force of the tool
rotating counterclockwise to
remove the screw.
Hand-piece torque: 30~50rpm / Reverse
3
4
Allow the screw to gradually
come out in a swaying motion.
40
Dentium Instruments
Manual
Help Kit
Abutment Hex Remover
­Application
To remove the remaining hex when the hex portion of an abutment is broken.
Advantage
Easy to remove the broken hex, as well as protect the internal threads of the fixture from being damaged.
Usage
1.Insert the tool inside into the remaining hex hole of the fixture inside.
2.Assemble the ratchet with the tool and rotate it in a CW (clockwise) direction to lock the tool tip with the remaining hex.
3.Disengage the ratchet and remove the remaining hex by gently rocking the tool.
4.If necessary, the hole located in the upper portion of the tool may be used with the crown ejector (not included).
*Caution: Do not overload the tool with pressure; apply moderate pressure.
1
2
Dual Abutment (Hex)
3
Rotate the tool clockwise so
that the remaining hex gets
tightly engaged to the tool.
4
Once the tool is tightly locked to
the hex remnant, disengage the
ratchet. Gently rock the tool until
the hex is successfully removed.
41
Dentium Instruments
Manual
Help Kit
Screw Tap Repair
Application
To recreate the internal thread lines of the fixture when it is damaged.
Advantage
Easy to recreate the internal threads with the help of the guides corresponding to different internal angulation
(8, 11 degrees) of the fixture.
Usage
1.Place the guide with corresponding degree to the fixture.
2.Assemble the tap tool with ratchet.
3.Start tapping using the tap tool with appropriate torque.
4.If excessive debris accumulates, pause tapping and remove using suction.
5.Repeat steps 3 and 4 until completed.
*Caution: Do not apply excessive torque onto the tap tool.
It is highly recommended to use the ratchet after the initial engagement of the tool and the internal threads.
1
IMPLANTIUM / SuperLine 11°
3
SimpleLine II 8°
4
Tap with the guide attached.
*If excessive debris accumulates, pause tapping and remove using suction.
42
Remove the tool and the guide
to suction the debris.
Dentium Instruments
Manual
Help Kit
Fixture Remover
Application
To remove the fixture when critically damaged with no other recovery options.
Advantage
Easy to remove the failed fixture without causing damage to the adjacent bone
Usage
1.Assemble the tool with ratchet, and insert it into the failed fixture to be removed.
2.Gently rotate the ratchet in a CCW direction until the tool is tightly locked into the fixture.
3.Continue to rotate the ratchet with greater torque in a CCW direction until the failed fixture is completely removed.
4.Separate the tool from the removed fixture by rotating it in a CW direction. If necessary, use the wrench (included) to
hold the fixture while rotating the tool with ratchet in a CW direction.
*Caution: Sufficient irrigation should be applied to the tool to prevent excessive heating during the procedure.
1
Art No. XRFRT
Art No. XRFRTO
SimpleLine II 8°
IMPLANTIUM / SuperLine 11°
2~3
4
Rotate the tool in a counter
clockwise direction until
it is tightly locked into the
fixture. Continue to rotate
with additional toque until
the failed fixture is
completely removed.
Separate the tool from the
fixture using the ratchet
and the wrench that are
included in the kit.
43
Dentium Instruments
Manual
Help Kit
Cover & Abutment Screw Remover
Application
To disengage the cover screw, healing abutment and abutment screw from the fixture
when the 1.28 hex on the head is stripped or damaged.
Advantage
Easy to disengage the cover screw, healing abutment and abutment screw with stripped or damaged hex.
Usage
1.Assemble the tool with the ratchet and place it over the damaged 1.28 hex of the cover screw, healing abutment or
abutment screw that needs to be removed.
2.Gently rotate the ratchet in a CCW direction to tightly engage the tapered top of the tool into the damaged 1.28 hex.
3.Continue to rotate the ratchet in a CCW direction with greater torque until the cover screw, healing abutment or
abutment screw is completely removed.
4.After the removal, rotate the ratchet in a CW to separate the tool and the removed component.
1
Cover Screw
2
Loading downward
Rotate the tool
counterclockwise until
tightly locked into the 1.28
hex of the cover screw.
3
Abutment Screw
4
Loading downward
Rotate the tool
counterclockwise until
tightly locked into the 1.28
hex of the abutment screw.
44
Dentium Instruments
Temporary Shell
Temporary Shell
Pre-fabricated Temporary Crown
• Aesthetic appearance that mimics the natural tooth
• Single and Multi-restoration for easy scissor-trimmed concept
8.6
7. 5
8.2
7.0
8 .4
8 .0
8.2
7.8
7.8
8.2
10.2
10.8
9.4
9.8
Regular
Wide
9.8
10. 5
10.6
11.2
7.6
8.0
7.6
Interproximal
Min. Thickness 2.0
6.0
5.8
7.7
5.7
5. 5
7. 2
8 .0
Occlusal
Min. Thickness 0.5
3.0˚
Jaw
Maxilla
Mandible
Position
Art. No.
Regular
Wide
Posterior-Left
TS 24 27 R
TS 24 27 W
Anterior
TS 13 23 R
TS 13 23 W
Posterior-Right
TS 14 17 R
TS 14 17 W
Posterior-Left
TS 44 47 R
TS 44 47 W
Anterior
TS 33 43 R
TS 33 43 W
Posterior-Right
TS 34 37 R
TS 34 37 W
45
Dentium Instruments
46
Manual
Temporary Shell
Healing
Temporary Abutment Connection
Temporary Abutment preparation
Temporary Shell try-in
Fill acrylic resin into the Temporary Shell
Placement of the Temporary Shell
Contouring the lower surface of the crown
to accommodate the emergence profile
Placement of Temporary Shell
Temporary Shell
Dentium Instruments
Dental Maintenance Tips
Dental Maintenance Tips
Disposable dental tips designed for the maintenance of dental implants including teeth grinding and polishing and
plaque removal
Titanium Tips
39
Ø3
Type
17
22
Ø1
Ø2.35
Ti Brush
Part No.
GDMT-Ti 3.0
3
39
Ø3
Type
17
22
Ø1
Ø2.35
Ti Brush
Part No.
GDMT-Ti 6.0
6
Urethane Tip
35
8.6
Ø2.35
Type
Part No.
Urethane
GDMT-U
Type
Part No.
Nylon Brush
GDMT-B
12.5
Brush Tip
31.5
Ø6.2
Ø4.2
Ø2.35
8.5
48
23
Dentium Instruments
Dental Maintenance Tips
Interdental Tips
39
Ø2
Type
Ø2.35
Ø0.44
Part No.
Ø4
Nylon Brush
11
GDMT-I-SSS
39
Type
Ø3
Ø2.35
Ø0.5
Part No.
Ø6
Nylon Brush
GDMT-I-M
11
39
Ø4
Ø0.6
Ø2.35
Type
Part No.
Nylon Brush
GDMT-I-L
Ø7
11
49
DENTIUM
LONG-TERM
CLINICAL
DATA
2002
2002. 05. 17
Pre-op
2003
2004
2002. 09. 04
Post-op
2005
2006
2003. 03. 15
Final prosthesis
2007
2008
2009
2010
2011
2012
2013
2014
2015
11 YEARS
2008. 04. 14
5 years
2013. 12. 05
11 years
OVER A DECADE OF
COMMITMENT TO
THE BEST PRODUCTS
FOR DENTISTS AND
PATIENTS
Dentium Instruments
for Total Solution
Catalog & Manual
HEAD OFFICE
3105 Trade Tower, 513 Yeongdong-daero, Gangnam-gu, Seoul, Korea 135-731
www.dentium.com / [email protected]
Specifications are subject to change without notice.
Some of the products listed in this catalog may not be available in the market due to pending approval.
1412 [Rev.2]