Dentium Instruments for Total Solution Catalog & Manual Index Surgical Guide Polymer Guide Implant Guide 04 06 Sinus Instruments DASK Osteotome Kit Sinus Elevator 11 16 17 GBR Instruments RS Kit GBR System Harvest Drill 19 24 35 Others Help Kit Temporary Shell Dental Maintenance Tips 38 45 48 Surgical Guide Polymer Guide Implant Guide Dentium Instruments Polymer Guide Polymer Guide Thermoplastic Surgical Template for Dental Implant Placement • Fabricate precise surgical template in just minutes using hot water • Disposable material to promote control of infection and contamination • Titanium sleeve is compatible with Dentium Guide and Final Drills Fully compatible with Dentium Drill System Thermoplastic surgical template Fabricate an accurate surgical template in just minutes, greatly reducing the lab and chairside time. 4 Suitable template shape Improved infection/contamination control Polymer Guide is designed to maximize contact area over the adjacent teeth while allowing substantial field of view during implant surgery. To ensure infection/contamination-free surgery every time, the Polymer Guides are made to be disposable. Drill a hole in the stone model Insert the Guide Pin Remove the Guide Pin Position the Polymer Guide intra-orally for drilling Soak the Polymer Guide in hot water above 65°C to soften up the material for easy molding. Apply of Polymer Guide on stone model Dentium Instruments Polymer Guide PGSSK PGSCK Single Standard (5ea) Cantilever Multi-Ready (5ea) 22 22 35 45 2.5 T 2.5 T * Average mesiodistal width of a tooth 7 * 1 fixed sleeve + 3 additional Sleeve holes [ Unit: mm, Scale 1 : 1 / mm ] T 2.5 Art. No. XSG 34 35 S T 2.5 Art. No. XSG 34 45 C Stone Drill XGD 23 60 (1ea) Guide Pin XGP 34 23 S (5ea) Guide Drill Brushing (First) XPGB 19 26 (1ea) Guide Drill Brushing (Second) XPGB 26 34 (1ea) Additional Metal Sleeve (for Cantilever Multi-Ready) XPGS 34 25 A (5ea) 5 Dentium Instruments Implant Guide Implant Guide Surgical guide utilizing silicon spacer and unique parallel pin • The tripod parallel pin is designed to take into consideration the mesiodistal width and drilling position in the edentulous area • Parallel pins and Spacers are configured based on the average width of a tooth Assist in the implant positioning as well as determining the width and the position of the prosthetic components The Guide Drill holes on the Tripod Parallel Pin help in prepping the osteotomy in the correct orientation The three legs of the Tripod Parallel Pin are of different lengths to accommodate varying widths of prosthesis for multiple unit bridges 6 Spacer + Guide Drill Ellipse Parallel Pin Final prosthesis Spacer + Guide Drill Ellipse Parallel Pin + Tripod Parallel Pin Final prosthesis Dentium Instruments Implant Guide GUIDE Ø2.2 Ø6.0 Ø7.0 Ø8.0 SPACER Ø9.0 Ø10.0 15 14 16 4.0 / 5.0 6.0 / 7.0 8.0 / 9.0 10.0 / 11.0 18 17 19 ELLIPSE PARALLEL PIN ISGK Kit Contents Guide Drill XLD 22 35S 10 XLDSP 60S XLDSP 70S XLDSP 80S XLDSP 90S XLDSP 10S 10 9 8 8 6 7 4 XPP 2226 50G XPP 2226 70G XPP 2226 90G XPP 2226 11G 14 19 16 XPP 2226 1416G 18 Tripod Parallel Pins 15 Ellipse Parallel Pins (x2) 6 17 Spacers XPP 2226 1719G 7 Dentium Instruments Implant Guide Spacers Diameter 6 7 8 9 10 6 7 8 9 10 6.0 Art. No. Ø6 XLDSP 60S Ø7 XLDSP 70S Ø8 XLDSP 80S Ø9 XLDSP 90S Ø 10 XLDSP 10S Ellipse Parallel Pins 4 6 11 9 7 5 8 10 10 8 6 4 8 Diameter Art. No. Ø4/Ø5 XPP 2226 50G Ø6/Ø7 XPP 2226 70G Ø8/Ø9 XPP 2226 90G Ø 10 / Ø 11 XPP 2226 11G 2.5 8 Tripod Parallel Pins 2 Width Ø 2.3 14 15 18 17 19 16 8 2.5 8 8 Art. No. 14 / 15 / 16 XPP 2226 1416G 17 / 18 / 19 XPP 2226 1719G Manual Dentium Instruments Implant Guide Single Case 8 8 Incision Guide Drill Combination of Guide Drill and Spacer Ellipse Parallel Pin Final Drill Ø 3.6 ~ Ø 5.0 Countersink Fixture placement with Healing Abutment SuperLine FX5010 Dual Abutment Connection Final prosthesis Ø 5.0 Multiple Case 19 18 17 Guide Drill Combination of Guide Drill and Spacer Guide Drill Application of Tripod and Ellipse Parallel Pin Final Drilling Fixture placement with Healing Abutment Ø 3.0 ~ Ø 5.0 Dual Abutment connection Final prosthesis NR Line NFX3611S / NFX4311S / NFX5011S 9 Dentium Instruments Sinus Instruments DASK Osteotome Kit Sinus Elevator 10 Dentium Instruments DASK Dentium Advanced Sinus Kit (DASK) • Simple & easy access to sinus cavity • Broad exposure of bony walls with special instruments DASK Drills XRT332035 Ø3.3 Type DASK Drill # REF DASK Drill # 1 XRT 332035 DASK Drill # 2 XRT 372035 DASK Drill # 3 XED 331035D DASK Drill # 4 XRT 064025 DASK Drill # 5 XRT 084025 DASK Drill v# 6 XRT 083025 12 10 8 6 4 2 0 Ø3.7 XRT372035 12 10 8 6 4 2 0 XED331035D Ø1.6 12 10 8 6 4 Crestal Approach Ø3.3 10 Lateral Approach XRT064025 Ø6.0 Ø4.0 * DASK Drill #1~5 : Drill speed 800 to 1,200 rpm, 30~45N∙cm with internal irrigation DASK Drill #6 : Drill speed 800 to 1,200 rpm, 30~45N∙cm with external irrigation XRT084025 Ø8.0 XRT083025 Ø6.6 Ø8.0 Ø1.5 Ø1.5 [ Unit: mm, Scale 1 : 1.2 / mm ] Stoppers | for XRT332035, XRT372035, XED331035D XFDST08 XFDST06 10.6 Ø5.14 [ Unit: mm, Scale 1 : 1 / mm] XFDST04 12.6 Ø5.14 XFDST02 14.6 Ø5.14 16.6 Drilling Depth L REF 08 10.6 XFDST 08 06 12.6 XFDST 06 04 14.6 XFDST 04 02 16.6 XFDST 02 Ø5.14 11 Dentium Instruments DASK Sinus Bur Kit SDK Sinus Elevation Instruments REF XSE1L REF XSE2L REF XSE3L REF XSE4L [ Scale 1 : 0.68 / mm ] Drills for Crestal Approach DASK Drill #1 XRT332035 DASK Drill #2 XRT372035 [800~1,200 rpm] The distance from the alveolar crest to the sinus floor should be measured on x-rays prior to surgery. Site preparation is performed with final drills in sequence up to 1mm short of the sinus floor. Then DASK Drill #1 or #2 is used and the sinus floor is carefully approached with light apical pressure. When you feel the yielding of the sinus floor, remove the drill. Or, partial preparations with DASK Drill #1 or #2 and up-fracture with osteotomes can be performed. * The internal irrigation not only provides a cooling effect, but also adds hydraulic pressure to slightly lift the sinus membrane during drilling. 12 DASK Drill #3 XED331035D [800~1,200 rpm] When the sinus cavity is accessed, DASK Drill #3 is introduced and a much broader detachment from the sinus floor can be facilitated horizontally with hydraulic pressure thanks to the internal irrigation hole. DASK Drill #3 can also be used for a lateral approach surgery. Dentium Instruments DASK Drills for Lateral Approach DASK Drill #4 XRT064025 DASK Drill #5 XRT084025 DASK Drill #6 XST083025 [800~1,200 rpm] To make a lateral window through the antrostomy (thin-out) approach. * DASK Drill #4 or #5 is used to prepare a lateral sinus window using light pressure and rotating stokes. The DASK Drill #4 or #5 is designed to minimize the risk of sinus membrane perforation. [800~1,200 rpm] To make a lateral window through the wall-off technique. * DASK Drill #6 is used to cut and detach a bony island like a trephine bur from the lateral wall. Uncontrolled overdrilling may lead to sinus perforation and possible damage to the membrane. External irrigation is necessary when drilling. DASK Maintenance Sterilization and Instrument Care Procedures • Please follow for legal regulations, as well as hygienic guidelines to prevent contamination and infection. • Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device. 1. All instruments, immediately after use, must be presoaked for a few minutes in a germicidal bath to loosen and prevent debris from attaching to instruments. Do not soak overnight. 2. Scrub with a soft brush to remove any debris. • It is important to use and follow, proper cleaning, disinfection and sterilization procedures. 3. For internal irrigation drills, use a reamer or small gauge needle to internally cleanout the drills. • It is also important to follow the manufacturer’s recommendation on use of drills. 4. Before using an ultrasonic cleaner, wrap drills in a 2 x 2 gauze to prevent rubbing against each other. • Please keep a log as to how many times the drills were used. 5. Rinse thoroughly with warm water. • Drill usage is determined by surgical site not per patient. Bone density and usage determine the life of the drills. • Drills should be considered for replacement after approximately 15- 20 uses based on bone density. Check drills frequently for wear. 6. Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit. 7. Dry completely and place back into kit. 8. Always check for damage or corrosion after rinsing and drying. 9. Seal the tray in a sterilization pouch. 10. Sterilize using a steam autoclave in 121°C/250F for 30 minutes or refer to manufacturer’s recommendations. 11. Store in a dry area at room temperature. 13 Manual Dentium Instruments DASK Crestal Approach (Sinus Lifting) 14 After Ø3.8 Final drilling, eliminate the residual bone (1mm) using a DASK Drill #1 or #2 (in hard bone) until you feel a slight drop. Detach sinus membrane using the domeshape sinus curette. Detaching the sinus membrane to create adequate space for graft material. Fill the sinus cavity with [OSTEON™ Lifting] graft material. Fill and distribute OSTEON™ graft material evenly throughout the achieved space. Placement of implant into the osteotomy Manual Dentium Instruments DASK Lateral Approach (Sinus Elevation) Wall-off Technique Detach sinus membrane using the domeshape sinus curette. DASK Drill #6 is used to cut a round bony island from the lateral wall like a trephine bur. Start to drill at a desired location and proceed until you see the shadow of the sinus membrane. Then, separate and lift the bony island up from the neighboring wall with a molt curette or a periosteal elevator. The bony island is repositioned back in its original position after bone augmentation. The first laser mark is 1.5mm and the second is 3.0mm. Overdrilling can cause sinus perforation and possible damage to the membrane. Elevate the sinus membrane to create adequate space for graft material. Thin-out Technique Elevate the sinus membrane to create adequate space for graft material. Fill the obtained space with [OSTEON™ Sinus] graft material. Thin down the lateral wall with DASK Drill #4 or #5 at a 45 degree angle to reach the Schneiderian Membrane. Move the DASK Drill #4 or #5 mesiodistally with a gentle pressure until you get the desired shape and size of the window for bone augmentation. The bony island can be repositioned after bone augmentation. Implant placed (SuperLine). 15 Dentium Instruments Osteotome Kit Osteotome Kit • Osteotomes compress the bone laterally, providing denser bony interface rather than removing valuable bone from the surgical site. Osteotomes | Final drill type XOF 20 A1 ØB ØA XOF 34 A1 XOF 38 A1 Type A Type XOF 43 A1 XOFK XOF 48 A1 A (Convex) [ Unit: mm, Scale 1 : 0.4 / mm] XOFBK B (Concave) 16 Type B (Convex) (Concave) Art No ØA ØB XOFK 20 A1 Ø1.7 Ø2.8 XOFK 34 A1 Ø2.3 Ø2.8 XOFK 38 A1 Ø2.7 Ø3.2 XOFK 43 A1 Ø2.8 Ø3.8 XOFK 48 A1 Ø3.0 Ø4.3 XOFK 20 B1 Ø1.7 Ø2.8 XOFK 34 B1 Ø2.3 Ø2.8 XOFK 38 B1 Ø2.7 Ø3.2 XOFK 43 B1 Ø2.8 Ø3.8 XOFK 48 B1 Ø3.0 Ø4.3 Dentium Instruments Sinus Elevator Sinus Elevator • Makes the sinus lift easy and drastically reduce the possibility of membrane perforation. • Balloon expansion of 0.5cc saline equals 6mm of membrane elevation. Ø3.70 Type 6.0, 1.0 X 6-lines Art. No. Including Syringe GSB38 Balloon Only GSB38B Balloon inflation size(mm) Injection Volume(cc) 6.0~6.5mm 4.0mm 0.5cc injection = Ø 6mm~6.5mm Expand the balloon progressively. Elevate the sinus membrane through the balloon inflation. Detach the sinus membrane to create adequate space for graft material. Carefully insert the Sinus Elevator into the osteotomy. Use [OSTEONTM Lifting] graft material to fill the sinus cavity. Placement of implant in the osteotomy. 17 Dentium Instruments GBR Instruments RS Kit GBR System Harvest Drill 18 Dentium Instruments RS Kit Ridge Spreader (RS) Kit • • • • Allows the achievement of space for implantation through the spreading of the bone with chisel and without drilling There are three types of Ridge Spreaders to create space up to Ø4.5 Convenient surgeries due to the compatibility with hand-piece and ratchet Easy-to-use kit component 19 Dentium Instruments RS Kit XRSK Kit contents Bone Chisel XBC305013 Ratchet XRCA1 Ridge Spreader Drills RS142435 RS203235 RS263635 20 Round Bur RS263635 Ratchet Adapter XRA3917 Mini Saw XDS8025 Dentium Instruments RS Kit Bone Chisel Art. No. XBC305013 Art. No. XRCA1 Ratchet [ Unit: mm, Scale 1 : 0.6 / mm ] Ridge Spreader Drills Ø2.4 Ø1.4 35 Ø3.2 Ø2.0 35 Ø3.6 Diameter L Art. No. Ø1.4 / Ø2.4 35 RS142435 Ø2.0 / Ø3.2 35 RS203235 Ø2.6 / Ø3.6 35 RS263635 Diameter L Art. No. Ø4.0 35 XRB4035 Ø2.6 35 Round Bur Ø4.0 35 Ratchet Adapter Art. No. XRA3917 17 Mini Saw Ø8.0 Diameter L Art. No. Ø8.0 25 XDS8025 25 [ Unit: mm, Scale 1 : 1 / mm ] 21 Manual Dentium Instruments RS Kit RS Kit + NR Line + OSTEON™ II + Collagen Membrane Incision Decortification Expansion with Bone Chisel Expansion with Ridge Spreader (20~60rpm / 30~45 N∙cm) - Expanding alveolar bone ridge to make space for fixture Fixture placement NR Line 3609W 22 Cover Screw connection Application of graft material OSTEON™ ll Manual Dentium Instruments Barrier membrane application Collagen Membrane Suture Dual Abutment connection Final prosthesis RS Kit Healing Abutment connection 23 Dentium Instruments GBR System Guided Bone Regeneration (GBR) System Guided Bone Regeneration • Allows the implantation of the GBR Technique with greater convenience • Multi-function membrane screw for membrane and/or abutment/plate fixation • Both GBR Abutment and Healing Abutment may be used with corresponding Plates and Screws GBR Plates • Supports membrane to hold up the graft material at desired volume • Easy to bend and cut • May overlap up to 3 plates with each abutment Membrane Screws • Multi-function membrane screws for membrane fixation and/or abutment/plate fixation Membrane Pins • Membrane pins for membrane fixation and/or plate fixation GBR Plates Straight Tripod-Groove Mandibular Total Osteotomy Matrix GBR Abutment Technique 24 Healing Abutment Technique Dentium Instruments GBR System GBR Abutment Technique Healing Abutment Technique GBR Abutment Ø3.5 Healing Abutment Ø4.0 - Ø9.5 18 18 3.0 Top 4.5 Top 0.3 Side 0.3 Side 28 28 3.0 Top 4.5 Top 0.3 Side 0.3 Side 21 30.5 5.0 32.7 * The tripod-Groove Plates can be cut in desired length and be used like a Straight Plate 3.0 4.5 44 37 2.5 Ø 1.5 Ø 1.5 10.0 8.0 6.0 4.0 2.5 Ø 1.5 Ø 1.5 Ø 1.5 Ø 1.5 Ø 1.5 Ø 1.5 10.0 8.0 6.0 4.0 Ø 1.5 Ø 1.5 25 Dentium Instruments GBR System Mandibular Total Osteotomy Technique A/H 4.0 6.0 8.0 5.5 3.7 A/H 2.5 Ø 1.5 Ø 1.5 Ø 1.5 10.0 8.0 6.0 4.0 Ø 1.5 Ø 1.5 [ Unit: mm ] GBR Mandibular Total Osteotomy 26 Dentium Instruments GBR System GBR Products GBR Abutment G/H Art. No. 2.0 GAB 35 20 G/H 2.0 Delivery Holder * Compatible with the SuperLine Fixtures. Compatible with Tightening Tool: Screw Abutment Hex (3.2 hex). Use no more than 10N∙cm of torque when tightening the GBR Abutment to the fixture. Ø 3.5 2.0 GAB3520 and FX4510SW [ Scale 1 : 1.5 / mm ] Healing Abutment Ø4.5 H 5.0 Ø 4.5 G/H 3.0 5.0 G/H3.0 HAB453050L and FX4510SW Diameter Ø4.0 Diameter Ø4.5 G/H H Art. No. G/H H Art. No. 2.0 2.0 HAB 40 20 20 L 2.0 2.0 HAB 45 20 20 L 2.0 3.5 HAB 40 20 35 L 2.0 3.5 HAB 45 20 35 L 3.0 5.0 HAB 40 30 50 L 3.0 5.0 HAB 45 30 50 L 4.0 7.0 HAB 40 40 70 L 4.0 7.0 HAB 45 40 70 L Diameter Ø6.5 Diameter Ø7.5 / 8.5 / 9.5 G/H H Art. No. G/H H Art. No. 2.0 2.0 HAB 65 20 20 L 3.0 5.0 HAB 75 30 50 L 2.0 3.5 HAB 65 20 35 L 3.0 5.0 HAB 85 30 50 L 3.0 5.0 HAB 65 30 50 L 3.0 5.0 HAB 95 30 50 L 4.0 7.0 HAB 65 40 70 L * Compatible with the SuperLine Fixtures. Use no more than 10N∙cm of torque when tightening the Healing Abutment to the fixture. Single use only. 27 Dentium Instruments GBR System GBR Plates Straight 18 18 3.0 Top 4.5 Top 0.3 Side 0.3 Side 28 28 3.0 Top 0.3 Side 4.5 Top 0.3 Side [ Scale 1 : 1.5 / mm ] Type Straight L T Art. No. 18 0.3 GBP 18 04 S 28 0.3 GBP 28 06 S Type Straight L T Art. No. 18 0.3 GBP 18 04 SH 28 0.3 GBP 28 06 SH Tripod-Groove 21 5.0 32.7 30.5 * The tripod-Groove Plates can be cut in desired length and be used like a Straight Plate 3.0 4.5 [ Scale 1 : 1 / mm ] Type L T Tripod-Groove 21 0.3 Art. No. GBP 21 13 T Type L T Tripod-Groove 21 0.3 Art. No. GBP 21 13 TH MTO Matrix 44 A/H 4.0 6.0 8.0 5.5 3.7 37 [ Scale 1 : 1 / mm ] 28 A/H [ Scale 1 : 1.5 / mm ] Type L T Matrix 44 0.3 Art. No. GBP 44 99 T Augmentation Height (A/H) Art. No. 4.0 GBP 40 37 M 6.0 GBP 60 37 M 8.0 GBP 80 37 M Dentium Instruments GBR System Membrane Screws 4.0 2.5 Ø 1.5 Ø 1.5 10.0 8.0 6.0 Ø 3.8 4.0 2.5 Ø 1.5 Ø 1.5 Ø 1.5 Ø 1.5 Ø 1.5 Ø 1.5 10.0 8.0 6.0 Ø 1.5 Ø 1.5 [ Scale 1 : 1.5 / mm ] L Art. No. L Art. No. 2.5 GSC 15 02 2.5 GSC 15 02H 4.0 GSC 15 04 4.0 GSC 15 04H 6.0 GSC 15 06 6.0 GSC 15 06H 8.0 GSC 15 08 8.0 GSC 15 08H 10.0 GSC 15 10 10.0 GSC 15 10H can be used with GBR Abutment Screw Case | 10 screws per case Membrane Pins Ø 3.0 2.75 Ø 0.5 Membrane Pin with insertion tool [ Scale 1 : 2 / mm ] L 2.75 Art. No. GMT 2525 C Pin Case | 10 pins per case 29 Dentium Instruments GBR System Instruments GBRK Kit Contents 30 Screw Drill GMD 1228 Hand-piece Insertion Tool Ratchet GST 26 H Hand-piece Adapter XMAA1 Torque Wrench Adapter XMA 21 W Screw / Membrane Pin Insertion Tool GST 85 Dentium Instruments GBR System Adapters | for Screw, Ball and GBR Abutments 20 Type Art. No. Hand-piece XMAA1 Torque Wrench 21 XMA 21W Screw Drill Diameter 10.0 Ø 1.2 Art. No. Ø1.2 GMD 1228 [ Unit: mm, Scale 1 : 1.5 / mm ] Compatible with Guide Drill Stopper 4.6 6.6 XLDST14 8.0 8.6 XLDST12 10.6 XLDST10 XLDST08 Assemble with Guide Drill Stopper 6.0 4.0 2.0 Ø 1.2 8.5 6.5 XLDST14 4.5 XLDST12 2.5 XFDST10 XFDST08 Screw / Membrane Pin Insertion Tools GST 26H Art. No. GST26H GST 56 GST56 GST 85 GST85 COD COD [ Unit: mm, Scale 1 : 0.7 / mm ] 31 Dentium Instruments Manual GBR System Case 1 OSTEON™ II Collagen + GBR Plate (Straight) GBR Abutment connection SuperLine : FX4510SE Application of graft material OSTEON™ II Fixation of Plate 0.3mm thickness /18.0mm length plate Fixation of Plate Plate with Membrane Screw 32 Fixation of Plate Plate with Membrane Screw Fixation of Collagen Membrane Membrane with pin Suture Dentium Instruments Manual GBR System Case 2 OSTEON™ II Collagen + GBR Plate (Tripod -Groove) GBR Abutment connection SuperLine : FX4510SE Application of graft material OSTEON™ II Fixation of Plate 0.3mm thickness / Cut-out Tripod-Groove plate Fixation of Plate Plate with Membrane Screw Fixation of Plate Plate with Membrane screw Fixation of Collagen Membrane Membrane with Screw Suture 33 Manual Dentium Instruments GBR System Case 3 OSTEON™ II + GBR Plate (Matrix) GBR Abutment connection SuperLine : FX4510SE Application of graft material OSTEON™ II Plate placement 0.3mm thickness / Cut-out Matrix plate Fixation of Plate Plate with Membrane Screw Suture 34 Collagen Membrane placement Dentium Instruments Harvest Drill Harvest Drill Collect autogenous bone and prep osteotomy simultaneously and effectively using the specially designed drills, the Harvest Drills. • Sharp, pointed tip to prevent drill chattering for precise drilling. • Drill stoppers applicable to control the depth of the drilling for safe and efficient bone harvesting, especially in the buccal side of the ridge. • Recommended drill speed of less than 100 rpm / 50N∙cm helps preserve the vital autogenous bone. • Excellent clinical results may be achieved when harvested autogenous bone is combined with Osteon™ II. Harvest Drills 8 101214 Ø 2.9 35 Ø 3.35 35 Ø 3.85 Diameter L Art. No. Ø2.9 35 XFH 34 35 Ø3.35 35 XFH 38 35 Ø3.85 35 XFH 4335 Ø4.4 35 XFH 48 35 35 Ø 4.4 35 Harvest Drill Stopper Ø 6.14 L Art. No. 15.9 XFHST04 15.9 4.0 First Guide Drill Ø 2.2 35 Diameter L Art. No. Ø2.2 35 XFH 22 35 Diameter L Art. No. Ø2.6 35 XFH 26 35 Second Guide Drill Ø 2.6 35 [ Unit: mm, Scale 1 : 1 / mm ] * Bone collection in the buccal side of ridge : 50~200rpm / 30~50N·cm 35 Dentium Instruments Harvest Drill Final Drill [2] 1 2 1 - First Guide Drill 2 ~ 4 - Harvest Drill 1000 rpm / 30~45N·cm with irrigation 30~100 rpm / 30~50N·cm without irrigation 4 3 Harvest Drill (Final Drill) First Guide Drill Second Guide Drill Ø 2.2 Ø 2.6 XLD 2235 XLD 2635 3.4 3.8 4.3 4.8 Ø 2.9 Ø 3.35 Ø 3.85 Ø 4.4 XFH 3435 XFH 3835 XFH 4335 * During the 4.3/4.8 fixture insertion into the bone density of D3~D4, the 3.35/3.85 harvest drilling process can be skipped. 36 XFH 4835 Dentium Instruments Others Help Kit Temporary Shell Dental Maintenance Tips 37 Dentium Instruments Help Kit Help Kit • Easy solution for critical problems which may occur in the prosthetics process • 5 tools in 1 kit (Screw Remover / Abutment Hex Remover / Screw Tap Repair Fixture Remover / Cover & Abutment Screw Remover) • Compatible with most dental implant products now available on the global market • Heavy duty with robust design and proven materials XIH Screw Remover 33 25 L Art. No. 25 XRF S2S 35 XRF S2 L Art. No. 20 XRHR 20 25 XRHR 25 Abutment Hex Remover 20 38 25 Dentium Instruments Help Kit Screw Tap Repair Type 11° 8° 25 Art. No. Tap XRSTR 11° Guide XRSG11 8 ° Guide XRSG8 Type Art. No. Fixture Remover 11° 8° XRFRTF 25 25 25 Remover XRFRT XRFRTO Wrench XRFRW L Art. No. 25 XRRHD 25 Cover & Abutment Screw Remover 25 39 Dentium Instruments Manual Help Kit Screw Remover Application To remove the remaining screw when the abutment screw is broken inside the fixture. Advantage Easy to remove the broken screw, as well as protect the internal threads of the fixture from being damaged. Usage 1.Set the torque of the implant motor to 30~50 rpm in a CCW (counterclockwise) direction. 2.Assemble the tool with the hand-piece. 3.Run the motor while keeping the tip of the tool appropriately contacted with the broken screw until successfully removed. *Caution: Do not overload the tool with pressure; apply moderate pressure. 1 2 Dual Abutment Use the friction force of the tool rotating counterclockwise to remove the screw. Hand-piece torque: 30~50rpm / Reverse 3 4 Allow the screw to gradually come out in a swaying motion. 40 Dentium Instruments Manual Help Kit Abutment Hex Remover Application To remove the remaining hex when the hex portion of an abutment is broken. Advantage Easy to remove the broken hex, as well as protect the internal threads of the fixture from being damaged. Usage 1.Insert the tool inside into the remaining hex hole of the fixture inside. 2.Assemble the ratchet with the tool and rotate it in a CW (clockwise) direction to lock the tool tip with the remaining hex. 3.Disengage the ratchet and remove the remaining hex by gently rocking the tool. 4.If necessary, the hole located in the upper portion of the tool may be used with the crown ejector (not included). *Caution: Do not overload the tool with pressure; apply moderate pressure. 1 2 Dual Abutment (Hex) 3 Rotate the tool clockwise so that the remaining hex gets tightly engaged to the tool. 4 Once the tool is tightly locked to the hex remnant, disengage the ratchet. Gently rock the tool until the hex is successfully removed. 41 Dentium Instruments Manual Help Kit Screw Tap Repair Application To recreate the internal thread lines of the fixture when it is damaged. Advantage Easy to recreate the internal threads with the help of the guides corresponding to different internal angulation (8, 11 degrees) of the fixture. Usage 1.Place the guide with corresponding degree to the fixture. 2.Assemble the tap tool with ratchet. 3.Start tapping using the tap tool with appropriate torque. 4.If excessive debris accumulates, pause tapping and remove using suction. 5.Repeat steps 3 and 4 until completed. *Caution: Do not apply excessive torque onto the tap tool. It is highly recommended to use the ratchet after the initial engagement of the tool and the internal threads. 1 IMPLANTIUM / SuperLine 11° 3 SimpleLine II 8° 4 Tap with the guide attached. *If excessive debris accumulates, pause tapping and remove using suction. 42 Remove the tool and the guide to suction the debris. Dentium Instruments Manual Help Kit Fixture Remover Application To remove the fixture when critically damaged with no other recovery options. Advantage Easy to remove the failed fixture without causing damage to the adjacent bone Usage 1.Assemble the tool with ratchet, and insert it into the failed fixture to be removed. 2.Gently rotate the ratchet in a CCW direction until the tool is tightly locked into the fixture. 3.Continue to rotate the ratchet with greater torque in a CCW direction until the failed fixture is completely removed. 4.Separate the tool from the removed fixture by rotating it in a CW direction. If necessary, use the wrench (included) to hold the fixture while rotating the tool with ratchet in a CW direction. *Caution: Sufficient irrigation should be applied to the tool to prevent excessive heating during the procedure. 1 Art No. XRFRT Art No. XRFRTO SimpleLine II 8° IMPLANTIUM / SuperLine 11° 2~3 4 Rotate the tool in a counter clockwise direction until it is tightly locked into the fixture. Continue to rotate with additional toque until the failed fixture is completely removed. Separate the tool from the fixture using the ratchet and the wrench that are included in the kit. 43 Dentium Instruments Manual Help Kit Cover & Abutment Screw Remover Application To disengage the cover screw, healing abutment and abutment screw from the fixture when the 1.28 hex on the head is stripped or damaged. Advantage Easy to disengage the cover screw, healing abutment and abutment screw with stripped or damaged hex. Usage 1.Assemble the tool with the ratchet and place it over the damaged 1.28 hex of the cover screw, healing abutment or abutment screw that needs to be removed. 2.Gently rotate the ratchet in a CCW direction to tightly engage the tapered top of the tool into the damaged 1.28 hex. 3.Continue to rotate the ratchet in a CCW direction with greater torque until the cover screw, healing abutment or abutment screw is completely removed. 4.After the removal, rotate the ratchet in a CW to separate the tool and the removed component. 1 Cover Screw 2 Loading downward Rotate the tool counterclockwise until tightly locked into the 1.28 hex of the cover screw. 3 Abutment Screw 4 Loading downward Rotate the tool counterclockwise until tightly locked into the 1.28 hex of the abutment screw. 44 Dentium Instruments Temporary Shell Temporary Shell Pre-fabricated Temporary Crown • Aesthetic appearance that mimics the natural tooth • Single and Multi-restoration for easy scissor-trimmed concept 8.6 7. 5 8.2 7.0 8 .4 8 .0 8.2 7.8 7.8 8.2 10.2 10.8 9.4 9.8 Regular Wide 9.8 10. 5 10.6 11.2 7.6 8.0 7.6 Interproximal Min. Thickness 2.0 6.0 5.8 7.7 5.7 5. 5 7. 2 8 .0 Occlusal Min. Thickness 0.5 3.0˚ Jaw Maxilla Mandible Position Art. No. Regular Wide Posterior-Left TS 24 27 R TS 24 27 W Anterior TS 13 23 R TS 13 23 W Posterior-Right TS 14 17 R TS 14 17 W Posterior-Left TS 44 47 R TS 44 47 W Anterior TS 33 43 R TS 33 43 W Posterior-Right TS 34 37 R TS 34 37 W 45 Dentium Instruments 46 Manual Temporary Shell Healing Temporary Abutment Connection Temporary Abutment preparation Temporary Shell try-in Fill acrylic resin into the Temporary Shell Placement of the Temporary Shell Contouring the lower surface of the crown to accommodate the emergence profile Placement of Temporary Shell Temporary Shell Dentium Instruments Dental Maintenance Tips Dental Maintenance Tips Disposable dental tips designed for the maintenance of dental implants including teeth grinding and polishing and plaque removal Titanium Tips 39 Ø3 Type 17 22 Ø1 Ø2.35 Ti Brush Part No. GDMT-Ti 3.0 3 39 Ø3 Type 17 22 Ø1 Ø2.35 Ti Brush Part No. GDMT-Ti 6.0 6 Urethane Tip 35 8.6 Ø2.35 Type Part No. Urethane GDMT-U Type Part No. Nylon Brush GDMT-B 12.5 Brush Tip 31.5 Ø6.2 Ø4.2 Ø2.35 8.5 48 23 Dentium Instruments Dental Maintenance Tips Interdental Tips 39 Ø2 Type Ø2.35 Ø0.44 Part No. Ø4 Nylon Brush 11 GDMT-I-SSS 39 Type Ø3 Ø2.35 Ø0.5 Part No. Ø6 Nylon Brush GDMT-I-M 11 39 Ø4 Ø0.6 Ø2.35 Type Part No. Nylon Brush GDMT-I-L Ø7 11 49 DENTIUM LONG-TERM CLINICAL DATA 2002 2002. 05. 17 Pre-op 2003 2004 2002. 09. 04 Post-op 2005 2006 2003. 03. 15 Final prosthesis 2007 2008 2009 2010 2011 2012 2013 2014 2015 11 YEARS 2008. 04. 14 5 years 2013. 12. 05 11 years OVER A DECADE OF COMMITMENT TO THE BEST PRODUCTS FOR DENTISTS AND PATIENTS Dentium Instruments for Total Solution Catalog & Manual HEAD OFFICE 3105 Trade Tower, 513 Yeongdong-daero, Gangnam-gu, Seoul, Korea 135-731 www.dentium.com / [email protected] Specifications are subject to change without notice. Some of the products listed in this catalog may not be available in the market due to pending approval. 1412 [Rev.2]
© Copyright 2024