Page 1 of 2 SUBMITTAL AM096FXVAFH/AA Samsung DVM S Series, Heat Pump Condensing Unit Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction System Specifications US Ton (nominal) Capacity (Btu/h) 8 Nominal / Rated Cooling¹ 96,000 / 92,000 Nominal / Rated Heating² System Modulation Down to (Btu/h) Performance EER Ducted / Non-Ducted IEER Ducted / Non-Ducted 108,000 / 103,000 7,513 11.6 / 15.0 23.0 / 38.2 Voltage (ø/V/Hz) Maximum Circuit Breaker (MCCB/ELB/ELCB) Power 3 / 208-230 / 60 50 Minimum Circuit Ampacity (MCA) N$ SCCR 5 Total Capacity (%) Indoor Units 37.8 50 - 130% Of Outdoor Unit Capacity Maximum Indoor Unit Quantity 16 Type Compressor SSC Scroll X 2 RLA (A) 12.5 Refrigerant R410A Factory Charge (lbs.) 16.31 Pipe Connections Liquid X Suction (inches) 3/8 X 7/8 Max. Distance - ODU to IDU (feet) Installation Limitation³ Vertical Separation (feet) ODU to IDU 656 (722 equivalent) 361 (ODU above) / 131 (ODU below) Highest/Lowest IDU Total Refrigerant Pipe (feet) Fan 164 3,280 Propeller X 2 Type Motor DC 620 X 2 Output (W) 3.0 FLA (A) Max. External Static Pressure ("WC) 0.31 51 X 66 3/4 X 30 1/8 WXHXD Inches Weight lbs. Sound Level dB (A) Max. Operating Temperatures Cooling °F 23 - 120 Heating °F -13 - 75 Dimensions 623.9 61 Safety Certifications Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube. Controls The unit shall be operated via NASA Protocol with controls provided by Samsung The outdoor unit shall have a removable EEPROM that stores unit serial number, startup information, system settings, and system tag/name. Controls shall integrate with a BMS system without additional interface modules Control wiring shall be 16 AWG X 2 shielded wire. Refrigerant System The compressors shall be Samsung hermetically sealed, inverter driven, direct vapor injected, DC scroll type with soft-start capability. ETL & ETLc Intelligent logic to ensure proper operation within unit design limitations and operational parameters High pressure sensor, low pressure sensor, over-voltage protection, compressor overcurrent protection, current transformer, fan motor voltage protection, fan motor thermal Protection Devices protection, overheat protection, phase detection protection, high voltage fuses Inverter PCB cooling done with liquid refrigerant to maintain optimal and safe operating temperatures Accessories Qty. Construction The unit shall be galvanized steel with a baked on powder coated finish. 9,182 Output (CFM) Type Condenser Fan Compatibility Only compatible with Samsung DVM S indoor units (AM****N*DCH***) Description Model Number WHG-SL Left wind/hail guard (1) WHG-SR Right wind/hail guard (1) WHG-R 5HDUZLQGKDLOJXDUGIRUWRQRXWGRRUXQLW WHG-T 7RSZLQGKDLOJXDUGIRUWRQRXWGRRUXQLW MCM-C200 Vapor injected compressors provide improved performance in cooling and heating modes. Refrigerant flow shall be controlled by EEV (electronic expansion valve) throughout the system. Subcooling devices in system maintain capacity at extreme system refrigerant pipe lengths and minimize refrigerant noise. Other Features Asymmetrical scroll design with rotating compressor operation/priority (where applicable). Optional night quiet modes to reduce outdoor unit sound (4 levels) Optional snow blowing logic to prevent snow accumulation on idle outdoor units Continuous operation while outdoor unit(s) change between heating and cooling modes (conditions apply). Mode selector switch for heat pump systems ¹ Nominal cooling capacities are based on: Indoor temperature: 80ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75ͼF WB. ² Nominal heating capacities are based on: Indoor temperature: 70ͼF DB, 60ͼF WB. Outdoor temperature: 47ͼF DB, 43ͼF WB. ³ Other pipe restrictions and requirements exist. 3OHDVHFRQVXOWWHFKQLFDOGDWDERRNRULQVWDOODWLRQPDQXDOVIRU IXOOGHWDLOVUHJDUGLQJOLPLWDWLRQVDQGRWKHUUHTXLUHPHQWVIRUYHUWLFDOVHSHUDWLRQRYHUIHHWRXWGRRUWRORZHVW LQGRRU Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or central control devices: DMS 2 (MIM-D00AN), BACnet Gateway (MIM-B17N), LON Gateway (MIM-B18N). Energy savings options to reduce system energy consumption in heating mode when average indoor room temperatures are greater than average indoor set temperatures. Samsung and Quietside maintains a policy of ongoing development, specifications are subject to change without notice. QS-DVMS-062015A www.SamsungDVM-S.com Page 2 of 2 SUBMITTAL AM096FXVAFH/AA Samsung DVM S Series, Heat Pump Condensing Unit AM096FXVAFH/AA Dimensional Drawing 66 3/4" 1 7/16" 30 1/8" 51" 4 1/4" 19 3/8" 6 3/4" 21 15/16" 2" 9 1/2" 4 13/16" 26 13/32" 24 1/4" LEFT SIDE RIGHT SIDE 7 15/16" 45 1/4" 22 5/8" 31 5/8" 29 31/32" 51" BOTTOM 1 Gas refrigerant pipe opening 5 Power conduit opening (4 X Ø1 3/4") 2 Liquid refrigerant pipe opening 6 Communication conduit opening (8 X Ø7/8") 3 Power conduit opening (2 X Ø1 3/4") 7 Knock-out opening for refrigerant piping (7" X 3") 4 Communication conduit opening (2 X Ø1 3/8") 8 Anchor bolt hole (4 X Ø15/32") 888-699-6067 www.SamsungDVM-S.com
© Copyright 2024