Page 1 of 3 SUBMITTAL AQN36VFUAGM / AQX36VFUAGM www.Quietside.com AQN36VFUAGM Max, wall mounted evaporator, single zone split system Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Specifications Nominal Capacity Cooling (Btu/h) Heating (Btu/h) Cooling (Btu/h) Capacity Range Heating (Btu/h) SEER / EER HSPF Condensate (pints/hour) Performance Voltage (ø/V/Hz) Working Voltage Range (VAC) Rated Current Cooling (A) (Low/Std./Max.) Heating (A) Max. Breaker (A) Min. Circuit Ampacity (A) Power WXHXD (inches) Indoor Unit Outdoor Unit Indoor Unit Weight (lbs.) Outdoor Unit Condensate Connection Dimensions Indoor & Outdoor Unit Heat Exchanger Type FPI Pipe Diameter Indoor Unit Outdoor Unit Sound Pressure Level (dB) Operating Temperatures (ͼF) Pipe Connections Refrigerant Compressor Indoor Unit Outdoor Unit Outdoor Indoor Indoor & Outdoor Cooling Heating Cooling Heating Aluminum Fin - Copper Tube 18 1/4 inch 2 row / 18 step 2 row / 52 step 33 / 46 58 14 T 115 5 T 75 61 T 90 T 80 1/4" 5/8" 164 / 10 98 High side (flare) Low side (flare) Type Control Method Factory Charge (oz.) Charged for Additional Refrigerant R410A Electronic Expansion Valve 88.1 25 ft. 0.43 oz./ft. over 25 ft. Manufacturer Type RLA (A) Samsung DC, Inverter Driven, Rotary 13.8 Cooling (Hz) 15 / 55 / 63 Heating (Hz) 15 / 50 / 69 Evaporator Fan Condenser Fan Motor Output FLA W Amps Condensate pump Wired Controller Accessories Standard Premium Interface module for central control Wall bracket (for outdoor unit) Line sets - insulated and flared, interconnect cables included Certifications Warranty 50 3/8 X 13 9/16 X 10 36 11/16 X 45 7/8 X 14 3/4 40 209 11/16" OD Maximum / Minimum Line Set Length (ft.) Maximum Vertical Separation (ft.) Operating Frequency (Low/Std./Max.) Devices AQN36VFUAGM 1 / 208-230 / 60 176 - 254 (max. 3% deviation from each) 3.6 / 14.2 / 18.0 3.3 / 14.5 / 21 30 19.5 (L/H) High Type Air Volume (max. CFM) W Consumption Operating Current (A) Safety 36,000 36,000 9,000 - 38,000 9,000 - 45,000 18.0 / 10.8 9.0 8.45 AQX36VFUAGM • Low ambient control built in • Outdoor unit shall provide 208/230V power to indoor unit via 14 AWG X 3 interconnect power cable • Electro-static, washable, HD (high density) main filter as standard Construction Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Refrigerant System The compressor shall be hermetically sealed, inverter controlled, Twin BLDC Rotary Refrigerant flow shall be controlled by EEV (electronic expansion valve) at outdoor unit Indoor Fan The indoor fan shall be a single, antibacterial cross-flow type Three fan speed settings and auto setting BLDC motor with cross-flow fan (1) 883 58 0.22 BLDC motor with axial fan (2) 248 1.04 ASP-MO-UNIV 110-250 AQN-WRS (includes sub-PCB and MWR-WH00 wired controller) AQN-WRP (includes sub-PCB and Controls Control signal shall be DDC type signal Interconnect control wiring shall be 16 AWG X 2 shielded wire between outdoor and indoor units Unit shall be operated via wireless controller (included) Optional wired control available Contact Quietside for details regarding central control applications, capabilities, and limitations MWR-WE10 wired controller with scheduling) MIM-B13D CKN-250 25' - ILS2509 50' - ILS5009 ETL & ETLc PCB fuses, indoor unit terminal block thermal fuse, current transformer, overvoltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing Convenience • Auto restart • Turbo mode (during cooling operation only) • Auto changeover • 24 hour timer • Good'sleep mode • Quiet mode • Dry mode 5 Years compressor, 3 Year Parts, 120 Day limited labor Nominal cooling capacities are based on: Indoor temperature: 80ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75ͼF WB. Nominal heating capacities are based on: Indoor temperature: 70ͼF DB, 60ͼF WB. Outdoor temperature: 47ͼF DB, 43ͼF WB. Quietside maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers. www.Quietside.com QS-RAC-112A Page 2 of 3 SUBMITTAL AQNVFUAGM / AQXVFUAGM www.Quietside.com AQNVFUA Max, wall mounted evaporator, single zone split system Page of 3 SUBMITTAL AQNVFUAGM / AQXVFUAGM www.Quietside.com AQNVFUA Max, wall mounted evaporator, single zone split system 27 3/16" 14 3/4" Top 15 7/8" (anchor point) Ø 7/16" anchor point 36 11/16" Front 25 1/8" 38 1/16" 45 7/8" 44 7/16" Right 3 3/4" 2 1/16" 10 5/16" 4 1/8" Bottom 10 5/8" For reference only. Always refer to installation manual for complete details. Minimum clearance from walls and ceiling Indoor Unit 11 3/4" minimum 5" minimum 5" minimum L3 L4 F1 F2 L3 L4 F1 F2 24" minimum 12" minimum L3 12" minimum 24" minimum Minimum clearance from nearby obstructions L4 Power to indoor unit L1 L2 F1 F2 Main Power Communication Outdoor Unit
© Copyright 2024