OEM pressure transmitter MH-3 for mobile working machines

Electronic pressure
measurement
For harsh operating conditions
Pressure transmitter MH-3
Applications
„„
„„
„„
„„
„„
Hydraulics
Load monitoring
Load moment limitation
Hydraulic drive control
Fluids in mobile working machines
Special features
„„
„„
„„
„„
„„
„„
Ratiometric current or voltage output
Accuracy up to 0.5 % of span
Measuring range 0 … 40 to 0 … 600 bar
Metric and all established pressure connections
6 different electrical connections
Adjustable diagnostic function
Data sheet PE 81.59
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30∙63911 Klingenberg∙Germany
Tel. +49 9372 132-0∙Fax +49 9372 132-406
[email protected]∙www.wika.de
14128874 04/2015 EN
OEM pressure transmitter MH-3
for mobile working machines
Developed and tested for mobile
working machines
The MH-3 pressure transmitter has been specifically developed for mobile working machines. Intensive field tests as well
as comprehensive internal testing ensure that the MH-3 is up
to the harsh demands of mobile working machines.
A large part of the testing is carried out in WIKA‘s own laboratories. In this way, individual customer requirements can be
taken into account.
Among the tests are:
Environmental influences
EMC influences
Shock/vibration
Pressure spikes
IP protection





The next step
Based on market experience with mobile working machines,
the MH-2 pressure transmitter has been enhanced. The existing look and feel of the proven forerunner has been retained.
The MH-3 has also had a diagnostic function added. In addition, signal clamping (limiting the signal value to a customer
settable value) is also available.
Signal clamping
Output signal with signal clamping at 21mA
Signal
21 mA
20 mA
Modern manufacturing
The in-house production of the sensor, the population of the
printed circuit board and the complete assembly on a fully automatic production line at WIKA enable continuous traceability of each individual manufactured unit, down to an individual
component level.
FL_MH-3_EN.indd 2
4 mA
Time
10.04.2015 17:15:59