Automatic Wash & Dry Toilet (Bidet) Warranty Period: One (1) Year BIDET USER MANUAL Distributor Contact Phone No. Purchase Date Date: , Month: , Year: If the purpose of general product is converted into business, warranty period decreases by half. Classification Trouble in performance or function during normal use within warranty period for parts Consumer Damage Type Within Warranty Period After Warranty Period Important repair is required within 10 days after purchase Product Exchange or Refund of Purchase Price N/A (Non-Applicable) Important repair is required within 1 month after purchase Damage generated during product transport and product installation when purchase is made Product Exchange or Free-of-Charge Repair N/A (Non-Applicable) Product Exchange (Installer is responsible for transport) N/A (Non-Applicable) Important repair is required within 1 month after exchange Refund of Purchase Price N/A (Non-Applicable) No exchange is possible Refund of Purchase Price N/A (Non-Applicable) The third occurrence of trouble by the same flaw Product Exchange or Charged Repair Refund of Purchase Price The fifth occurrence of trouble by different flaws Product Exchange or Charged Repair Refund of Purchase Price Refund of the amount The company lost the product requested Product Exchange or calculated by straight for repair by consumer Refund of Purchase Price line depreciation Repair is impossible due to no repair parts available during the warranty period for the parts Refund of the amount Product Exchange or calculated by straight Refund of Purchase Price line depreciation Repair is impossible Exchange of product after charging the amount corresponding to repair cost Product exchange with application of depreciation after receipt of repair cost Repair is impossible Charged Repair Charged Repair Charged Repair Charged Repair Trouble by consumer's fault Trouble by consumer's careless handling and incorrect repair -Trouble by wrong use of gas type, gas pressure, and electricity capacity -Trouble or damage by outside shock or drop -Trouble by using consumables or option products, which are not designated by our company -Trouble by no observance of "cautions" in user manual Charged Repair Charged Repair Other cases • Trouble by natural disaster (lighting, fire, damage from sea water, and flood damage) • Life of consumable parts ends Charged Repair Charged Repair Trouble by consumer's intention or mistake No product trouble like device cleaning, adjustment, user manual and installation: Simple adjustment with user manual and without assembling External environment trouble like internet, antenna, and wired signal Initial installation on product and reinstallation due to poor installation by sales shop Problems by installation change due to product transfer or move Cleaning of product inside, dust and head, and removal of alien substance Trouble by other products including software) Please read this User’s Manual carefully for proper operation and maintenance and keep this manual well together with the warranty. USER MANUAL PRODUCT WARRANTY Dear Customers First of all, we would like to thank you very much for purchasing this Ionia Bidet. This product is superior to the ones in the past in function and we believe that it will provide you with clean and healthy bidet. We would like to recommend you to read this User’s Manual carefully for proper operation and maintenance and keep this manual well together with the warranty. TABLE OF CONTENTS Name of Component 02 Safety Precaution 05 Please Prepare Prior To Use 08 How to Use 10 It would be of help if you know !!! 16 How To Repair 18 In Case of No Use over a Long Period 24 Prior to Request for Repair 25 Installation Manual 26 Product Specifications 37 In Case of Service Request 38 1 Name of Component It is convenient to know the name of each component of bidet. IB-3000 Stop Button It stops cleaning bidet dry movement. Cleaning/Move Button It is used for cleaning. Water Tank Bidet/Move Button Seat Cover It is used for bidet cleaning. Water supply hose Power Plug Deodorizer (only IB-3000) Cleaning Indicator Lamp Lamp is on during cleaning. Stop Cleaning /Move Lamp is on while bidet is on use. Dry Button It dries moisture with warm air after cleaning. Dry Temperature/Water Pressure Control Indicator Lamp Bidet/M ove DRY Nozzle(bidet) Nozzle(cleaning) Pre-Filter It controls warm water temperature. Seat Button Seat body Water Shutoff Valve It controls seat temperature. Deodorizer Button Control Panel Toilet LOW HIGH Dry/Wate r Pressu re Warm Water Control Button Touch Sensor Automatic Indicator Lamp Lamp is on while automatic function is on use. Front·Rear Control Button It controls position of cleaning and bidet. It is ON/OFF switch of deodorizer. REAR FRONT Nozzle Power Saving Button It is ON/OFF switch of power saving function. Power Button It is ON/OFF switch of power. M Warm Water H L SEAT TEMP DEODOR POWER SAVING M Automatic Button Press for automatic function use. Cleaning and dry function works automatically. Strong/Weak Control Button Use for strong and weak control on cleaning, bidet water pressure and dry temperature. H L Warm Water Temperature Indicator Lamp Lamp is on while warm water is used. Seat Temperature Indicator Lamp Power Water supply hose Dry Indicator Lamp Lamp is on during dry movement. FULL AUTO It displays dry temperature and water pressure control. Connector Bidet Indicator Lamp IB-3000 Lamp is on during seat temperature control. Deodorizer Indicator Lamp Lamp is on while deodorizer works. Power Saving Lamp Lamp is on while power saving function works. 2 3 Safety Precaution Name of Component IB-1000 In order to prevent safety accident caused by incorrect use and to use products conveniently, the precautions are shown as various picture symbols. Read the manual after fully understanding the following symbols and their meanings; Stop Button Cleaning/Move Button It is used for cleaning. Bidet/Move Button It is used for bidet cleaning. Lamp is on during cleaning. Stop Cleaning /Move Bidet Indicator Lamp Lamp is on while bidet is on use. Water Pressure Indicator Lamp Bidet/M ove Strong/Weak Control Button Use for strong and weak control on cleaning, bidet water pressure and dry temperature. Front·Rear Control Button It controls position of cleaning and bidet. It controls seat temperature. REAR Lamp is on while warm water is used. FRONT M Warm Water H L SEAT TEMP M Seat Temperature Indicator Lamp Lamp is on during seat temperature control. H Lamp is on while power saving function works. Each symbol indicator has the following meaning: "Do not try. ( It is a general prohibition symbol) "Do not touch" Keep any flammable materials away from this product. Be sure to carry out instruction (It is a symbol indicating general action.) Power Display Lamp 4 * Wound : It refers to abrasion, burn (high, low temperature) and electric shock, which do not require hospitalization or being long-term outpatient for treatment. * Property Damage : It refers to the damages, which are expanded to housing, building, household items, livestock, and covers. Do not touch with wet hands. L It is ON/OFF switch of power saving function. It is ON/OFF switch of power. Indicates a hazardous situation, which, if ignored and used incorrectly, which may result in injury or property damage. POWER SAVING Power Saving Lamp Power Button Caution "Do not assemble" Nozzle Power Power Saving Button Indicates a hazardous situation, which, if ignored and used incorrectly, which could result in serious injury. Warm Water Temperature Indicator Lamp HIGH Water P ressure Seat Button Warning "Be Cautious!" It is the symbol requiring precaution like "caution" "warning." Be sure to read and observe precaution. LOW It controls warm water temperature. Indicates a hazardous situation, which, if ignored and used incorrectly, which will result in death or serious injury. Cleaning Indicator Lamp It displays water pressure during water pressure control. Warm Water Control Button Danger It stops cleaning bidet dry movement. Plug out power cord. If power is ON, lamp is turned on. Connect grounding wire. 5 Safety Precaution CAUTION WARNING Do not lean against toilet cover. * Toilet cover may be broken, which causes falling down or getting hurt. Do not step on or apply shock. * You may get hurt by falling down. Prevent from freezing. * Once it is frozen, main unit is damaged, which may cause water leakage. Do not install at freezing environment. * It may cause electric shock or injury. When sterilization & purification filter is pulled out, be sure to close water supply valve. * If water supply value is not closed completely, it may cause water leakage. Do not strain water hose to connection pipe by force. * Pipe shaking may cause water leak. Do not obstruct warm air or deodorizer outlet. * It may cause fire, trouble or noise. Be cautious not to have fingers caught in toilet lid or during opening and closing of toilet * If fingers are caught, they may get hurt. Do not urinate on the nozzle. * It may cause odor or trouble. Do not use if main unit or toilet is damaged. * It may cause electric shock or injury. For outside repair, plug out power cord from the outlet. * Otherwise, it may cause electric shock. Caution in Use. When the following people use the product, guardian should be cautious not to have them fall down when they sit on or rise from toilet: children, the old and the infirm, and people who can not sit on or rise from toilet. When people rise from toilet, if they repeat the motion like leaning forward while they sit on, it may cause injury as main unit is fallen off from main unit fixing plate. Be sure to grab main unit when it is lifted and moved. * If toilet or toilet lid is lifted, it may cause separation from main unit or injury. 6 Be sure to completely turn off sterilization & purification filter, if it was pulled out before. * It is not closed completely, it may cause water leak. If power cord is damaged, replace cord for prevention from any danger by contacting manufacturer or service center, or by number. 7 Please Prepare Prior To Use Be sure to check the following items before bidet is used: 1 Check whether water supply shutoff valve is open. 3 If water supply shutoff valve is closed, open it by turning to the left. In case of being opened, be sure to bring it back to the original position as it is adjusted. Check cleaning. 1.Detect by placing hand on the part where toilet seat sticker is attached. 2.Press cleaning button. 3.If nozzle comes out, block water by covering its end with hand. Water supply shutoff valve 2 Connect power plug to outlet. 1.Insert power plug in AC 230V or 120V outlet. (Use outlet with grounded outlet box.) 230V or 120V 2.Check whether cleaning and bidet lamp are turned on at control panel. If power plug is inserted, cleaning and bidet lamp flickers. If cleaning or bidet button is pressed, water entering begins. Once water entering ends, flickering of cleaning and bidet lamp automatically disappears. If lamp is not turned on, connect power plug again. Warning 8 H L H M M t TemSea perature L Bidet/M ove Cleaning /Move Turn on Connect grounding completely. ★ In case of trouble or electric leakage, it may cause electric shock. ★ In case of outlet with no grounded box, install after consultation with specialized equipment shop. 4.To stop cleaning, push stop button. Check other functions after reading user manual. ★ It has a built-in touch sensor, which detects seated person. Cleaning, bidet, deodorizing, and drying do not operate unless person is seated. 9 How to Use 1 Press cleaning button POWER SAVING DEODO R SEAT TEMP WARM WATER POWER IB-300 0 REAR STOP (How To Adjust Temperature) FRONT Warm water from nozzle does bidet cleaning (female exclusive use) Warm water from nozzle does general cleaning. IB-3000 ■ Seat 1 Press bidet button HIGH ★ Water does not get warm instantly. If button is pressed 10 ~ 15 minutes before used, it can be used pleasantly. ★ Whenever button is pressed, indicator is converted into "OFF", "LOW", "MEDIUM" or "HIGH." ■ Bidet (female exclusive use) LOW Whenever button is pressed, indicator lamp is converted. Set desired temperature. ■ Cleaning DRY/W ATER P RESSU RE POWER POWER SAVING DEODOR SEAT TEMP Water temperature is adjusted with warm water button. Model : IB-3000 FULL AUTO H L M H L M WARM WATER Nozzle REAR FRONT After connecting power plug, check whether 'Low' lamp of warm water and seat button is turned on. ★ In case that no lighting is maintained, connect power plug again. Once 'Low' lamp of warm water and seat button is on, product stands ready to operate. (How To Adjust Temperature) DRY ■ Warm Water BIDET/M OVE ■ Power Connection ■ Simple Operation Operation is simple!!! CLEANIN G/MOV E Please Prepare Prior To Use!!! If bidet is adjusted as follows prior to use, it may be used more pleasantly. Adjust seat temperature with seat button. Whenever button is pressed, indicator lamp is converted. Set desired temperature. ★ Seat does not get warm instantly. If button is pressed 10 ~ 15 minutes before used, it can be used pleasantly. ★ Whenever button is pressed, indicator is converted into "OFF", "LOW", "MEDIUM" or "HIGH." 3 Press stop button to stop. water pressure button for 2 Press adjustment of cleaning strength. ★ It has a built-in self-stop function for automatic stop of general cleaning and bidet cleaning one minute later respectively. Warning In case that the following people use the product, seat button should be set at 'Low' or 'OFF' and close attention is required by their guardians: children, elderly people, people who are unable to adjust temperature by themselves, people with weak skin, people with sensitive skin, people taking sleeping pill, and people suffering from heavy drinking or over work. ★ If used for a long time, it may cause low-temperature burn. 10 Warning If cleaning strength is adjusted to low where tap water pressure is low, nozzle may not come out. In this case, adjust cleaning strength to high. 11 How to Use ■ Adjustment of Nozzle Position Model : IB-1000 ■ Cleaning ■ Bidet (female exclusive use) 1 Press cleaning button Warm water from nozzle does general cleaning. 1 Press bidet button Press "Front" or "Rear" button at nozzle location. Initial Position Cleaning location can be adjusted to four(4) levels during general cleaning or bidet cleaning. Warm water from nozzle does bidet cleaning (female exclusive use) Cleaning position is adjustable. 3 Press stop button to stop. ★ It has a built-in self-stop function for automatic stop of general cleaning and bidet cleaning one minute later respectively. water pressure button for 2 Press adjustment of cleaning strength. Warning Unless nozzle moves for cleaning or bidet, location adjustment function does not work. ★ Reference Warning If cleaning strength is adjusted to low where tap water pressure is low, nozzle may not come out. In this case, adjust cleaning strength to high. 12 Nozzle can remember its last used position, which is automatically set up for next use. 13 How to Use ■ Deodorizing (IB-3000 model only) ■ Drying 1 Press Dry Button Warm air dries wet spot during cleaning. 2 Press 'High' or 'Low' Button for change of warm air temperature. deodorizing while being seated. 1 Start By pressing "Deodorizer" button while you sit on the seat, deodorizing function of ON/OFF can be adjusted manually. Whenever button is pressed, indicator lamp is converted. Set desired temperature. ★ While 'Dry' is on use, deodorizing stops temporarily. ★ Deodorizing cartridge, which absorbs odor from bidet main unit, is installed. 3 In case that you may wish to convert "Deodorizer" to 'OFF' ● How To Operate Once 'Deodorizer' button is pressed, 'Deodorize' indicator lamp is turned off and no 'Deodorizer' function works. If you wish to turn it on, press 'Deodorizer' button. Deodorizing stops automatically two(2) minutes later after operation.. ★ Caution Deodorizing function may not work properly under the following cases: • When 'Deodorizer' filter is contaminated • Bad odor by foods • Seven(7) years after replacement ■ Power Saving Caution 3 Press stop button to stop. Use with Dry Button at 'Low' for elderly people, people who are unable to adjust temperature by themselves, or people with weak skin. ※ Drying at high temperature may cause burn. ★ Reference Warm air dry function stops three(3) seconds later after stop button is pressed for product durability. ★ Reference If dry button is pressed after wiping out water with tissue after cleaning, drying can be made faster. ■ Automatic Function (IB-3000 model only) 1 ● Power Saving 1 Press power saving button. (refer to the below for indicator lamp ON) Power saving continues till setup is released, and, while on use, the temperature of warm water and seat gets back to the previous set up condition for operation. IB-3000 ★ It is on power saving mode while not used (indicator lamp is ON). ★ Power saving function stops while on use (indicator lamp is OFF) ★ In case of power saving, you may feel chilly due to low temperate of warm water and seat. In that case, use after releasing power saving. Press automatic button If automatic button is pressed, automatic indicator lamp is turn on and cleaning and drying are made automatically. All family can use conveniently with automatic function. 14 Power saving is the function to save electricity consumption by lowering temperature of warm water and seat while it is not used. IB-1000 2 Press power saving button again for release (indicator lamp is OFF). 15 It would be of help if you know !!! Warm water volume and temperature? • Capacity of warm water tank is 0.85 L. it can be used continuously at a certain temperature or higher by adopting continuous warm water type. Touch sensor is installed. Touch sensor is installed to prevent water gushing by pressing button by mistake when you do not sit on seat. Therefore, if you do not sit on seat, each function including cleaning, bidet, deodorizing and drying does not operate. • Control temperature inside warm water tank - Low: about 32℃ - Medium: about 36℃ - High: about 40℃ When nozzle does not come out in case that water pressure adjustment button is at "weak" This bidet is structured to gush water by pushing out nozzle by water pressure. If water pressure adjustment button is set at "weak," nozzle may not come out. In this case, adjust water pressure adjustment button to "strong." Water comes out from nozzle part after you sit on the seat or comes out before and after cleaning or bidet operation, which is designed to maintain cleanness of nozzle, and is not a failure in nozzle operation. ★ In case of other cases or non-stop running of water, contact purchase shop after closing water supply shutoff valve and plugging out power cord. It may have some smells if it is used for the first time, which disappears soon after initial use. Don't worry about this. ★ In case of smell, it generates only once after installation. Touch sensor Slowly closing seat and seat cover Water comes out from nozzle part? If you use the product for the first time, it may have some smells Soft closing function is installed for slow closing to reduce shock when seat and seat cover are thrown down by mistake, ★ If you close by straining too hard, it may cause trouble. About energy saving The following is effective for energy saving: • Always activate power saving button. • Adjust seat or warm water temperature pleasantly, but not too high. • Set the temperature, which fits in with four seasons • Turn the power off while you are out for long time. ★ In case of concern on damage by winter freezing, refer to how to prevent winter freezing. In case of static at radio or TV If radio or TV is placed closer to bidet, it may cause static. In this case, use radio or TV by relocating it to a place with no generation of static. 16 17 How To Repair ■ Normal Repair Caution When repair is done, be sure to check whether power lamp at main body operation panel is off by pressing power button. Warning Warning Do not pour water or detergent into main unit. Do not spray water or detergent on main unit or power plug part. ★ It may cause electric shock or fire. Do not use detergent for bathroom, household detergent, bleaching agent, benzene, sinner, or cresol for repair of plastic parts. ★ Broken resin may cause injury, electric shock or fire. ★ Clean with water-soaked soft cloth. Repair Method of Seat Main Body SINNER ※ Seat cover can be separated from the product easily. Also, since seat main unit can be separated from toilet, the gap between toilet and seat main unit can be cleaned well. BENZENE ● Wipe with soft cloth soaked with water. If dirtiness is left untouched, it does not wipe well. Thus, wipe well frequently. If it is wiped with water-soaked cloth, it prevents static electricity. Static electricity, which attracts dust, may cause dirtiness. How To Repair Nozzle ● Take out the nozzle and if its hole for water gushing is dirty, clean with tooth brush. ★ Do not strain or bend nozzle by force. About Antibiotic Nozzle • Antibiotic resin is applied to nozzle part. Abut Antibiotic Product Warning Remove dust on power plug regularly. When dust is removed, plug out power cord and remove dust with dry cloth. ★ Insulation defect many cause fire. 18 • Antibiotic product has the effect of restraining propagation of bacteria, but antibiotic effect does not work well in case of dust or oil is covered with surface. • Antibiotic product has the effect of restraining propagation of bacteria on the surface of the product, but can not remove bacteria completely. Therefore, it can not prevent from infection. 19 How To Repair ■ Remove Seat Lid and Clean ■ How To Detach Main Unit ★ It is convenient if you wish to clean every corner. How To Assemble Seat Lid Caution Be sure to check whether power lamp at control panel of main unit is turned off by pressing power button. 1. Plug out power cord from the outlet. 2. Close the water supply shutoff valve for no water supply. How To Detach Seat Lid 1. Detach seat lid from main unit hole by grabbing left corner and stretching outward while lifting lid slightly. 2. Separate the lid from main unit by pressing seat lid to the right. Caution: If you try to detach by force, it may cause damage including breaking. Seat Lid Pressing stretching 3. Separate main unit from fixing plate to the arrow direction by pressing attach/detach button. 4. Place main unit on the toilet lightly. Caution Do not use the seat with the lid being detached. ★ If you use the product with the detached seat lid, it may cause damage. How To Assemble Seat Lid 1. Insert seat lid in main unit by fixing into the right pin at main unit. Pin Hole 2. Assemble the seat lid by stretching the left corner of the lid outward and fixing into main unit hole. Caution 1. Be sure to plug out power cord from the outlet. ※ If there is no water at warm water tank, it may cause smoke or fire. ※ Be careful not to drop into the toilet. 2. Do not strain cords or main supply water hose. ※ It may cause damage or leakage. 3. When you detach main unit or clean it, handle with care. ※ Otherwise, it may cause leakage or break down. 4. Never tilt or turn over main unit with power on ※ It is the cause of malfunction. Seat Lid ● Do not put it on the floor. ● Do not have it lean against. Inserting ● Do not tilt main unit. ● Do not turn main unit upside down. ● Do not strain. Pin ※ Water supply between T-shaped connector and main unit is connected by the connector, not by main unit, you can not detach and clean main unit. 20 21 How To Repair ■ Cleaning by Detaching Whole Main Unit (How To Attach/Detach Main Unit Slide) General Cleaning Method Toilet Cleaning ■ You can clean easily by separating main unit. After cleaning is over, fix with attach/detach button after attaching main unit. Opening 1. Separate main unit from fixing plate to the arrow direction by pressing attach/detach button. 1. Wash out after wringing out water-soaked soft cloth enough. 2. Wipe toilet clean with water-soaked soft cloth. 2. Wash stains on dirty part by soaking soft cloth with household neutral detergent and then wipe out with soft cloth. 3. Insert main unit into fixing plate to the reverse direction from separation. • Do not use the detergent containing cleanser or abradant because it may generate scratch on main unit case or toilet seat. Locking ※ Do not use acid or alkali detergent as it corrodes metal part inside main unit. Caution ■ Caution in Toilet Cleaning When main unit is separated, separate while pressing attach/detach button of fixing plate. Otherwise, it may cause malfunction or damage. • When you wipe toilet, bathroom detergent may damage to main unit by volatile gas. Clean within a short period of time. • Do not have main unit stained with bathroom detergent. Caution Main Unit Cleaning ■ Wipe with soft sponge or cloth soaked with a neutral detergent. • Do not use hydrochloric acid detergent or benzene. (It may cause change in shape or color of main unit.) • First of all, plug out power cord. - There is a danger of electric shock. Plug out power cord. Do not have main unit and plug stained with water and detergent. It may cause electric shock or fire. Nozzle Cleaning ※ Notice Wipe water-soaked toilet and tank frequently. • Condensing water generated during rainy season or by heating in winter becomes cause of mold by getting floor or wall wet if it is left untouched. Wipe it out or ventilate. Replacement Parts ■ Brush nozzle gently with soft brush. • Be careful not to get nozzle hole damaged. • Do not brush with tough scrubber. • Lift up seat lid and seat. • Clean by pulling the end part of cleaning or bidet nozzle forward Water Purification Filter 22 Prohibition of Water Spray 1. Replace water sterilization & purification filter periodically to maintain performance. • This filter is composed of three(3) steps of micro filter, sterilization resin and ion exchange resin. It removes foreign substances and floating matters under water and finally, sterilizes marine microbes (bacteria, fungi, algae and etc.) with sterilization resin. • Filter life varies depending upon water quality, water pressure and amount used, and the recommended replacement cycle of this filter is 5 ~ 6 months. • Purchase water purification filter for replacement or other consumables from our company-designed serve centers. 23 In Case of No Use over a Long Period Prior to Request for Repair Be sure to drain water for the following cases: • When bidet is not used over a long period including travel. ( Water gets dirt, which may cause clogging.) • When bidet is not used at vacation home. ( As temperature decreases faster than expected at housing with no people, it may cause freezing or leakage.) ■ If you think the product is in trouble, check the following items prior to request for repair because you can fix it easily: Trouble Water Drainage and Power Shutoff 1. Stop water supply by closing water supply shutoff valve. ★ Since water supply shutoff valve is adjusted, remember the original position (how much turned). 2. Drain water from warm water tank by pulling out drain cork of warm water tank. ★ Fasten drain cork after draining water completely. Power lamp is Off 3. Separate water hose to main unit. ① Drain water completely by lifting main unit water hose. ② Assemble water hose again after water drainage. • Is temperature adjustment switch OFF? Adjust to proper temperature by pressing adjustment button of toilet seat temperature or warm water temperature. Cleaning water does not come out well. • Is water supply valve open completely? Open all by turning water supply valve axle to the opening direction. • Is nozzle stained with slime or foreign substance? Clean nozzle with soft brush. • Is water sterilization & purification filter clogged? Stop water supply and replace water sterilization & purification filter (about 5 ~ 6 months) • Is it the area with low water pressure? Check water pressure. Pull out drain cork of warm water tank by turning with driver. 4. Be sure to conduct a test run if used again. Main Unit Water Hose ■ If no water comes out due to freezing If no water gushes out due to freezing of main unit supply hose or water supply connector, defrost slowly by getting main unit supply hose or water supply connector warm with warm water-soaked cloth or defrost naturally by warming up inside. Caution Do not apply hot water or hot air to main unit water hose. ★ It may cause damage to main unit water hose. 24 • Is power switch off? Have power switch ON. • Is power plug plugged in completely? Plug in power plug. Seat cover is cold. Cleaning water is cold. Water Supply Shutoff Valve Close Check Point, Cause and Action Water leaks outside continuously • Is connecting part of water supply valve fastened tightly? Fasten again connecting part of water supply valve • Is rubber packing at each connecting part missing ? If rubber packing is missing, insert and fastening it again. • Is water purification filter clogged? Replace water purification filter by stopping water supply. ※ Contact sales store for the following cases: • Power lamp, power saving lamp and deodorizing lamp of main unit flicker ( It indicates abnormal function with operation of product's self-diagnosis function) • Warm air does not come out from warm air dry outlet. • Power lamp is not turned on although power plug is plugged in the outlet. 25 Installation Manual ■ Observe for Safety! Caution This is the caution for prevent accident on use by installing bidet safely. Read the manual prior to installation and install well so that no accident occurs. Do not damage, destroy, process, bend by force, strain, twist, bind, insert in groove, put on heavy stuff on power cord. ■ Terminology Explanation Warning -> It indicates that mishandling could cause death or severe injury to user. ※ Damage to power cord may cause electric shock or fire. Do not use except for AC 230V or 120V ※ It may cause electric shock or fire. Caution -> It indicates that mishandling could cause minor injury or material damage to user. If filter is detached, be sure to close supply water shutoff valve. Also, when filter is installed, fasten tightly with no gap. ※ Filter part may cause water leak. Warning Fasten water supply pipe tightly. ※ If you do not fasten screws, it may cause water leak. Never dissemble, repair or remodel except for qualified technician. ※ It may cause electric shock or fire and get hurt by abnormal operation. Be sure to adjust water supply shutoff valve and check water leak after installation. ※ it may cause property damage by water leak. Do not pour water or detergent into main unit. Do not have main unit or power plug part stained in water. ※ There may be concern on electric shock or fire. Drain water in case of a concern on freezing till you sell to customer. ※ Water leak by freezing breakage may cause property damage. Be sure to install the earthing. ※ There may be concern on break down or electric shock by leakage of electricity. ※ If there is no ground terminal on the outlet, consult professional technician. Do not connect power until installation is complete. ※ Damage may cause water leak. When damaged power plug is plugged in the outlet, do not use in case of getting loose. ※ It may cause electric shock or fire. Do not connect to water service except for tap water. Preparation Tool Monkey wrench (adjustable up to 24 mm) or spanner More than 24 mm. ※ It may cause bladder infection, dermatitis and electric shock or fire by corrosion of machinery inside. More than 24 mm Driver 24 mm Do not plug out or in with wet hand. ※ it may cause electric shock. 26 27 Installation Manual ■ Power and Water Supply Check Check Parts (Check Packing Contents) ■ about Power Outlet Bidet Main Unit • Use the outlet, which is suitable to AC 230V or 120V and maximum rating 600W • The length of power cord is 1.3 m. • Install the outlet at a place, which is higher than the floor and keeps water out of reach, within the scope of power cord. • Be sure to do earth connection (the third class earth connection). ※ In case that the outlet is newly installed or changed, be sure to consult electric installation shop with the care of the above things. ※ Do not plug in power plug to the power outlet until installation is complete. There is a concern on breakdown. Fixing Volt Moving Plate T-Shaped Connector Fixing Plate Rubber Nut Main Unit Water Supply Hose (Length 50cm) ■ Water To Use ? Packing (black: width 2 mm) • Be sure to connect water supply to water service. If you use gray water, industrial water or underground water, durability of electric parts or machinery parts worsens and it may cause accident. Also, it may cause bladder infection, dermatitis and electric shock or fire by corrosion of machinery inside. • Use water supply pressure at 0.07MPa{0.7kgf/cm2}~0.075MPa{7.5kgf/cm2}. In case of other ranges, contact purchase shop for consultation. • Connect water supply to water supply shutoff valve at toilet. In case of installing flash valve toilet, taking water supply separately, or connecting water supply shutoff valve at toilet to gray water, consult purchase shop. Fixing Nut Check Toilet 1. Measure toilet size. 2. Is corner tank-type toilet satisfy ① or ②? • There are some cases where you can not install bidet depending upon toilet. Check measurements shown at the picture below. 13~20cm More than 39cm Check Bathroom Inside • If bidet is installed at toilet, it is shown as the picture Unit : cm More than 3 below. Check the sufficient space at bathroom inside and 19.6 any obstacle. 48 28.4 53 28 More than 3 More than 5cm More than 47cm In case of corner tank-type toilet, if it meets the requirement of either the picture ① or ②, it can be installed. ① A: more than 22 cm ② A: more than 13 cm or B: more than 17 cm If it does not fall under ① or ②, you need to take measure to move tank location. (Inquire to purchase shop.) 3. Usability Requirement for Main Unit Water Supply Hose (enclosed) Although the enclosed main unit water supply hose is 50 cm long, the proper distance between T-shaped connector and main unit water supply socket is not longer than 70 cm (Refer to the picture below) 70cm 29 Installation Manual Thank you so much for purchasing Ionia bidet. 1 Installation on T-Shaped Connector • Install correctly after reading this installation manual well. Caution Dear Customers Dear Installation Company • Be sure to do a test run afte installation. We ask you to understand that we are not responsible for any trouble in case that the product is installed by other installation methods than this manual. Contact purchase store for consultation on product or product installation. Ionia Co. can install the product, but separate installation fee will be charged. Be sure to deliver this user manual & warranty to customers. Installation Diagram Caution • Use attached T-shaped connector. ※ Attach T-valve to water supply valve, and connect water tank and T-valve with tank hose. T-Valve Water Shutoff Valve 1. Close water supply shutoff valve. Explain how to use when they are passed on. Block water supply by fastening water supply shutoff valve tightly. ※ Since water supply shutoff valve is adjusted, remember the original position (how much turned). Water Supply Shutoff Valve Close Name of Each Component 2. Remove existing water supply pipe. (1) Release the nut at tank, during which a small amount water flows over. Put floor cloth underneath. Tank Nut (2) Remove the existing water supply pipe by releasing the nut on water supply shutoff valve. water supply pipe Release Release Caution • Do not apply excessive force to water supply shutoff valve or water supply pipe. ※ It may cause damage and water leak. water supply pipe In case that water supply pipe is flexible, this work is not required. 3. Install T-Shaped Connector. Install T-shaped connector to water supply shutoff valve by inserting packing (black: width 2mm). (Tightening torque 100~150 kgf•cm Note) If the above tightening torque does not fit in, it may cause damage or leakage. 30 T-shaped connector Water supply pipe connector Main unit water supply connector Water supply shutoff valve 31 Installation Manual 2 Installation on Main Unit Water Supply Hose (Main Unit Side) Installation Diagram 3 Installation on Main Unit of Bidet Disassembly of Existing Toilet Seat An example of floor water supply type Seat Main unit water supply hose 1. Close water supply valve connected to toilet water tank. water supply socket 2. Unscrew nut by spanner. water supply hose Nut Toilet 3. Remove fixing nut and rubber packing and disassemble toilet seat. Main Unit Attachment (1) After removing protection cover, connect main unit water supply hose to water supply outlet. Water supply outlet (2) Fasten main unit water supply hose tightly by fitting in with water supply outlet. Main body water supply hose Main unit water supply valve Caution • Check whether supply hose has packing inside. Caution 1. Unscrew fixing nut, rubber packing and fixing screw from mounting bolts. 2. Locate installation base to the position by fitting in with product size, place it put on toilet and insert moving plate and mounting bolts. Attach the bolts to the main unit by fitting in the Warning groove at the installation base so that they can not move around. 3. Tighten by using rubber nut and fixed nut. 4. Place the main unit on the toilet. ① This product is adjustable to 130 ~ 200 mm by setting to toilet seat attach hole. Caution ② When the main unit is attached, fix with care so that its location and the center fits in with. When the main unit is separated, separate while pressing attach/detach button of fixing plate(installation base). Otherwise, it may cause trouble or damage. • Check to see if it is fixed tightly. ※ No packing or damage on packing may cause water leak. 32 33 Installation Manual 4 Installation on Main Unit Water Hose (T-shaped Connector side) (1) Insert water sterilization & purification filter into T-shaped connector. T-shaped connector Caution • Check whether water hose has packing inside. ※ No packing or damage on packing may cause water leak. 6 Power Connection 1. Plug in power plug to the outlet. 2. Check to see if power is ON. 1. Plug in power plug to the outlet. 2. Check to see if cleaning and bidet lamp at control panel is ON. If power plug is plugged in, cleaning . bidet lamp flickers. If cleaning or bidet button is pressed, water starts to enter and flickering of cleaning . bidet lamp disappears. If lamp is not turned on, connect power plug again. (2) Fasten filter tightly like the main unit. Main Unit Water Hose Caution If it is not fastened tightly, it may cause water leak. Caution 5 Check Water Supply T-shaped Connector Part (1) By turning water supply shutoff valve to the right to the original position, supply water to the tank and the bidet. Open • In case that water supply to the tank stops or is not made, check to see if float touches with the wall at tank inside. If so, fix it as follows: (1) Make ball tap stand by unscrewing nut at tank. (2) Fasten tank nut again by pressing ball tap by hand. • Do not pull out the filter with water supply shutoff valve open. ※ It may cause leakage at filter part. 34 Automatic Be sure turn on the power after completing installation with toilet. ■ Test Run ( Once installation is complete, do test run with the following tips) Water Supply Socket Part Caution Dry (3) Fasten main unit water hose to filter tightly. ▶ Be sure to install the grounding. ※ In case of trouble or leakage, it may cause Warning electric shock. ※ If the outlet has no grounding box, install through request to professional installation shop. Bidet/M ove O-Ring Cleaning/ Move LED Lighten (2) Check any leak at each connecting part by adjusting cleaning handle of tank. ※ In case of leakage, fasten nuts again and check assembly status. 1. Check to see if 'low' at warm water and seat is turned on. 2. Check cleaning. (1) Seat sensor, which detects sitting on the seat, is installed. Cleaning, bidet and drying does not operate unless you sit on the seat. Adjustment is possible by attaching silver tape on the detection part of the seat sensor or detecting with hands. For location, refer to the picture at the right. Cleaning (2) Press cleaning button. Since water gushes with this, block with hand so that it does not splatter around. As tank is empty at first, it takes 1 ~ 2 minutes for water to gush. (If you adjust cleaning strengh to 'Strong,' water gushes faster.) Press stop button when you stop cleaning. 3. Check bidet. Press bidet button like cleaning. Water gushes about 25 mm father than cleaning location as bidet nozzle comes out. (3) Check whether water is collected and it stops after that. ※ If water is not collected in tank or water does not stop, check ball tap. If seat sensor is not detected, each function of cleaning, bidet and dry does not work. Caution If that's the case, try again by checking the location of white paper or cloth. 35 Installation Manual Stop Button Use to stop operation Product Specifications Strong . Weak Adjustment Button Use for adjustment of 'strong . weak' of cleaning and bidet. Automatic Button Press for use of automatic function. cleaning and dry function works automatically. Product Name Seat Button Model Name Use for proper adjustment of seat temperature. Dry and Warm Water Adjustment Button Power Button Use for adjustment of dry and warm water temperature. Press this when you want to do power ON/OFF. Cleaning . Bidet Dry Deodorizer Button It dries watery part with warm air after cleaning. Bidet/Move Button Front . Rear Adjustment Button Use for adjustment of the location oof cleaning & bidet nozzle Power Saving Button Press for ON/OFF of power saving function. Deodorizer Press for feminine wash. Press when you deodorize. Seat Press for anus cleaning. Cleaning water is sprayed. Dry Button Water Pressure Supply Range Power Supply 70 ~ 753kpa(0.7 ~ 7.5 kgf/cm²) Rated Wattage 600W Dimension 480(W)x530(D)x160(H) 36 Close 5.3 kg 5 kg Warm Water Tank . Capacity 850 cc Nozzle Slide Type Water Pressure Cleaning Spray Volume 0.5~0.7L/min Bidet Spray Volume 0.5~0.7L/min Warm Water Heater Capacity 550W Warm Water Temperature 4 levels conversion(OFF(normal temperature)/33℃/36.5℃/40℃) Safety Device Temperature Fuse, High-Temperature Prevention Device Capacity 0.4 m³ / minute Warm Air Heater Capacity 265 W Warm Air Temperature Adjustment 4 levels conversion(OFF(normal temperature)/38℃/45℃/53℃) Safety Device Temperature Fuse, High-Temperature Prevention Device Heater Capacity 40 W Surface Temperature OFF(normal temperature)/LOW(26℃) /MEDIUM(36℃) /High(40℃) Temperature Adjustment 4 level conversion (Mycom control) Safety Device Temperature Fuse Deodorizing Type Deodorizing Cartridge Life Catalyst Deodorizing Replacement Period about 7 years Automatic saving by detection on seating Power Cord About 1.8 m Temperature Supply Range 5~40℃ Seating Sensor Function Other Function Caution Be sure to close water supply shutoff valve when you pull out filter. Also, when you install filter, fasten tightly for no gap. ※ It may cause water leakage ( refer to page 29.) AC 230V, 50/60 Hz / AC 120V, 50/60 Hz Automatic Function In case that water does not come out well when you use water purification filter, replace filter. Purification Filter IB-1000 Direct Connection to Tap Water Power Saving Function (1) Close water supply shutoff valve. Water supply shutoff valve is adjusted, remember the original location (how much turned) (2) Pull out the filter at the bottom left of the main unit. (3) Replace with new filter. (4) Fasten filter tightly. (5) Open water supply shutoff valve to the original position. IB-3000 Water Supply Type Product Weight Cleaning/Move Button Automatic Wash (Dry Type) Toilet Dry Function Seat Part Soft Closing Function Power Saving Function Main Unit Slide Detach Function Continuous Warm Water Function Soft Cleaning Function ※ Exterior design and product dimension is subject to change without any notice to consumers for improvement of product quality. 37 In Case of Service Request MEMO Customer's Right Customer has a valuable right to receive free service within warranty period from the purchasing date in case of occurrence of any trouble while on use of product. However, in case of customer's fault or natural calamity, we would like to let you that it will be our paid service even during the warranty period. Responsibility for Paid Service ( Customer's Share of Expense) When service is requested, the following cases falls under paid service even during the warranty period: 1) Occurrence of trouble by throwing foreign substances(water, beverage, coffee, toy, and etc.) into product. 2) Occurrence of product damage or malfunction by outside shock during installation or use. 3) Damage or deformation of external appearance of product by organic solvent like benzene or sinner. 4) Occurrence of trouble by using other parts or consumables than Ionia's formal product. 5) Occurrence of trouble by no observation on installation manual. 6) Occurrence of trouble by wrong use of gas type, gas pressure or electricity capacity. 7) parts are lost or damaged by random disassembly of product by customer. 8) Occurrence of trouble by repair or remodeling through other people than Ionia's repair engineers. 9) Occurrence of trouble by natural calamity(lighting, fire, damage from storm and flood, gas, damage from sea water, earthquake, and etc.). 10) Occurrence of trouble by not observing "warning and caution for safety) on Ionia product user manual. If you keep wanting and caution for safety, you can use product longer. 38 39 MEMO 40 MEMO 41
© Copyright 2024