TecomTM Series / Control Panels TS0816 Challenger Control Panels Overview Interlogix’s Challenger V8 integrated security platform is widely considered the leading commercial security system in Australia and New Zealand. Challenger is used in universities, financial institutions, retail stores, supermarkets and prisons, to name only a few. The Challenger system consolidates access control, intrusion detection, video surveillance, and communications in one platform. Combined with modular hardware, distributed intelligence, and powerful software, a Challenger security platform can be scaled for any application. Cardholders enjoy the convenience of one-card operations, using the same card action to open doors while disarming areas (or locking doors while rearming areas). Challenger panels can report alarms and other programmed events in Contact ID format (CID) to the central station and/ or management software via the onboard dialer. The optional TS0898 IP interface provides 128-bit encrypted IP connections for alarm reporting and for system management, in which case the panel’s onboard dialer can be used as a backup in case IP communications are lost. Local annunciation and detailed reporting are also available, by user- selected schedules and areas, so that security professionals can install custom intrusion detection systems for every client. Features • • • • • • • • • • • • • Up to 16 remote arming stations (keypad or reader) can be connected Up to 256 inputs and 64 doors with use of expansion modules Up to 255 freely programmable relay outputs Memory expansion modules enable a Challenger panel to store 1,000 each of alarm events and access events (100 for standard memory) Memory expansion modules enable a Challenger panel to accommodate up to 65,535 users Programmed via LCD keypad arming stations or via Interlogix Security management software Arming and disarming can be automated to occur at particular times, days and/or when particular events occur in a system Programmable holidays modify existing access restrictions Management software computers may be connected locally via direct RS-232, by modem, or via IP connection Built-in dialer for monitoring or for remote system management Optional interfaces for IP or RS-232 connections Permissions for individual users to arm and disarm areas, permission to access doors, lifts, and floors (or other equipment) in Challenger’s access control system System input devices can be monitored for tamper conditions Extensive macro logic functionality can be used to program complicated sequences of events (for example, to prevent two doors from being opened simultaneously). Challenger constantly polls devices on the RS-485 data bus to check for online status. The system’s input devices can be monitored for tamper conditions (open or shorted) in addition to the default monitoring for sealed or alarm conditions. www.interlogix.com.au Powerful System Architecture The TS0816 Challenger panel is the heart of the system, and comprises a modular ‘Add as you go’ design. You can cost-effectively add capacity and function as it is required, by adding intelligent door or lift controllers, input/output expanders, memory expanders and LAN devices. Multiple panels can be linked together in one system via management software. Challenger uses a cost-effective and reliable RS-485 data bus for communications between Challenger hardware that is capable of running long distances while minimizing cable runs. Challenger data can even be carried by optical fibres (optional interface modules required. System Block Diagram Memory expansion modules expands users to over 65,535 IUM users Backup PSTN line to monitoring stations Monitoring Station Monitoring Station Specifications System Features System areas Inputs on board Max. system inputs Outputs on board (relays) Door control on master control panel 12 VDC auxiliary power output Supports access control Supports lift control Max. access control doors (when using TS0867 or TS0866) Anti-passback 16 16 256 Exterior siren, interior siren, strobe Yes 700mA (max.) Yes (requires TS0866 or TS0867 Intelligent 4-Door Controllers) Yes (requires TS0869 Intelligent 4-Lift Controller) 16 on panel plus 48 on 4-Door Controllers IP connectivity Yes (requires TS0866/TS0867) Yes: TS0882 (1 MB), TS0883 (4 MB IUM), TS0884 (8 MB IUM) and software IUM are supported IP connection using TS0898 Ethernet Interface RS-232 serial connection using TS0091 Computer and Printer Interface RS-232 serial connection using the Challenger panel’s onboard serial port (temporary connection only, typically used by installers) Modem connection using the Challenger panel’s onboard modem (dialer) Modem connection using an external modem connected to TS0091 Yes (requires TS0898 Ethernet Interface) Modem Onboard V.22bis modem (300 or 2400 baud) Input voltage 16V, 1.5A from supplied transformer (space for 7 Ah battery allocated) Operating Current 200mA maximum (no peripheral devices fitted) Battery test Dynamic battery testing Relays or outputs Use expansion modules and DGPs to add up to 255 relays or outputs Macro logic programs Strobe 24 Two 8 Ohm sirens, internal and external. The external siren is monitored for tamper conditions 1 Reporting formats CID, Extended high speed, Serial STU, Tecom Dialler, Direct Line and more Communications bus RS-485 Maximum cabling distance 1,500 m (unless extended by LAN Isolation Interfaces) Memory expansion Management software connection options Sirens System Capacity Users Alarm groups Door groups Floor groups Alarm log Access log Holidays/Special days Time zones Physical and Environmental Operating temperature Dimensions in enclosure (W x H x D) Regulatory Compliance 50 (expandable to 65,535) 128 to 245 10 to 255 10 to 128 100 to 1,000 100 to 1,000 24 24 to 46 ‘hard’ time zones plus 16 ‘soft’ time zones 0 to 500c 345 x 450 x 73 mm ACMA: C-Tick for Australia and New Zealand ACMA: A-Tick for Australia New Zealand Telecom: Telepermit for New Zealand Ordering information TS0816 TS0816B TS0808 TS0816S Challenger V8 panel with plug pack in TS0307 enclosure Challenger V8, board only Challenger V8 panel with plug pack in TS0307 enclosure, 8 inputs EPROM with current version of firmware TS0816 Interlogix National Sales Enquiries 1300 361 479 271-273 Wellington Road Mulgrave Vic 3170 T +61 3 9239 1200 F +61 3 9239 1298 Challenger Control Panels Offering industry-leading solutions designed for a wide range of applications, Interlogix products are well suited for residential and commercial environments. With ongoing partner support and a commitment to technology that addresses current and future needs, you can count on Interlogix to deliver global security solutions to meet the demands of the modern world. interlogix.com.au Specifications subject to change without notice. © 2013 Interlogix. All rights reserved. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. TS0816-DS-131030-4
© Copyright 2024