SNDEXT-4 4 way monitored sounder circuit extension card PRODUCT OVERVIEW SNDEXT-4 has been deisgned to provide a sounder circuit extension solution. The card has 4 monitored and fused sounder cicuits. There are switched negative inputs to trigger all circuits (common) or each circuit individually, a relay is also provided for remote fault monitoring. The fault relay will operate for all faults including loss of 24v supply input. The card is driven from an existing sounder circuit in the control panel. A permanent 28v supply is required. If used with a Haes Excel-EN control panel, this supply can be taken from the 28v output on the main circuit board. Each circuit is fused at 0.75 amp via self healing fuses and requires a 4K7 end of line monitoring resistor (provided). SNDR1 + - PARTS INCLUDED SNDR2 SNDR3 + - + - SNDR4 + - SUPPLY 28V 0V A Nylon self adhesive pillar CIRCUIT ACTIVE SNDR1 SNDR2 SNDR3 SNDR4 TPCA09 FAULT B M3x6 Screw x4 S+ SINPUT CARD DETAILS NC NO C FAULT - FLT x4 C M3x25 Screw x4 D Fixing Kit 6x15mm Spacer x4 1 2 3 4 ACTIVATION(-) 1 2 SNDR1 + - 8 7 SNDR2 SNDR3 + - + - CIRCUIT ACTIVE SNDR1 SNDR2 SNDR4 SUPPLY 28V 0V + - SNDR3 SNDR4 FAULT S+ SINPUT 9 NC NO C FAULT - FLT 1 2 3 4 ACTIVATION(-) 1 Monitored sounder circuits, fused at 0.75 amp, 4K7 end of line resistor 2 28v supply input 3 Switched negative input for common sounder circuit ringing (subject to link from 28v supply to S+) 4 Switched negative inputs for activation of individual sounder circuits 1 - 4 5 Switched negative common fault output 6 Fault relay, NO/NC changeover (fail safe) 7 Sounder circuit fault LED indicators, open or short circuit 8 Sounder circuit active LED indicators 9 S+, S-, sounder circuit drive input 6 3 5 4 Approved Document UI-SNDEXT-01 Issue 1.0 SNDEXT-4 Sounder circuit extension card INSTALLATION The sounder circuit extension card has been designed to utilise an existing sounder circuit and is therefore compatible with most makes of conventional fire alarm control panel. Four, self adhesive, nylon, mounting pillars (A) are provided to enable the card to be mounted into a suitable space. If, however, the card is to be mounted into a Haes, Excel-EN control panel, it has been designed specifically to fit neatly into a zone card slot and fixed using 4 x M3x6 screws (B) as provided. Alternatively, if the Excel-EN is fully loaded, the sounder circuit card can be piggy backed over an existing zone card using 4 x M3x25 screws and 4 x 6x15mm spacers (C & D) as provided. FIT IN PLACE OF ZONE CARD PSU @ + - 28V 0V + - C FIRE NC NO C FAULT NC NO FR FLT CC PUL SNDR1 SNDR2 -OP -OP -IP -IP + - + - ZONE A ZONE1 ZONE2 ZONE3 ZONE4 + - + - + - + - + - ZONE B ZONE C + - + - SNDR1 ZONE D + - + - SNDR2 SNDR3 + - + - CIRCUIT ACTIVE SNDR1 SNDR2 SNDR4 + - SNDR3 SUPPLY 28V 0V SNDR4 FAULT 1 2 1 ON 2 3 4 TWIN D C B A ON + - 3 BATTERY - - OPA OPB C + - NO AUX + - SNDR A S+ SINPUT SNDR B NC NO C FAULT - FLT 1 2 3 4 ACTIVATION(-) Zone Card (TPCA04) Sounder Ext Card (TPCA09) Fix using 4 x M3x6 screws (B) as provided PIGGY BACK OVER EXISTING ZONE CARD PSU @ + - 28V 0V + - C FIRE NC NO C FAULT NC NO FR FLT CC PUL SNDR1 SNDR2 -OP -OP -IP -IP + - + - C C D D ZONE A ZONE1 ZONE2 ZONE3 ZONE4 + - + - + - ZONE B + - + - SNDR1 + - ZONE C + - + - SNDR2 SNDR3 + - + - CIRCUIT ACTIVE SNDR1 SNDR2 ZONE A ZONE D + - + - SNDR4 + - ZONE B ZONE C + - + - SUPPLY 28V 0V SNDR3 SNDR4 FAULT TWIN + - 1 2 3 2 ON 1 4 3 2 ON 4 TWIN D C B A 1 D C B A ON 3 BATTERY - - OPA OPB S+ SINPUT NC C NO AUX NO C FAULT - FLT + - SNDR A + - SNDR B 1 2 3 4 ACTIVATION(-) Piggy back sounder card ontop of existing zone card and fix using 4 x M3x25 screws and 6x15mm spacers as provided Approved Document UI-SNDEXT-01 Issue 1.0 ZONE D + - SNDEXT-4 Sounder circuit extension card CONNECTION DETAILS FOR COMMON SOUNDER RINGING FROM EXISTING SOUNDER CCT Permanent 28v supply Can use 28v O/P from Excel-EN main PCB (500mA) or seperate power supply unit. SNDR1 + - SNDR2 SNDR3 + - + - CIRCUIT ACTIVE SNDR1 SNDR2 SNDR4 + - SNDR3 SUPPLY 28V 0V SNDR4 FAULT S+ SINPUT + Existing Sounder CCT - NC NO C FAULT - FLT 1 2 3 4 ACTIVATION(-) EOL Sndr CCT Approved Document UI-SNDEXT-01 Issue 1.0 SNDEXT-4 Sounder circuit extension card CONNECTION DETAILS UTILISING INDIVIDUAL SWITCHED NEGATIVE CONTROL Permanent 28v supply Can use 28v O/P from Excel-EN main PCB (500mA) or seperate power supply unit. SNDR1 + - SNDR2 SNDR3 + - + - CIRCUIT ACTIVE SNDR1 SNDR2 SNDR4 + - SNDR3 SUPPLY 28V 0V SNDR4 FAULT S+ SINPUT NC NO C FAULT fault relay contacts OP 1 IP 1 programmed as fault IP OP 2 Approved Document UI-SNDEXT-01 Issue 1.0 - FLT 1 2 3 4 ACTIVATION(-) Individual circuit activation from switched negative inputs
© Copyright 2024