Agenda City of Hudson Oaks 210 North Lakeshore Drive Hudson Oaks, Texas 76087 Planning & Zoning Commission Meeting Tuesday, April 14, 2015 7:00 p.m. Workshop Session 7:00 p.m. 1. Parliamentary procedure review Regular Session to directly follow worshop 1. Call to order/announce a quorum is present (4 of the 6 member being present constitutes a quorum) 2. Citizen comments 3. Consideration of Planning & Zoning Commission minutes for March 10, 2015 4. Presentation and discussion regarding Accessory Building Regulations 5. Furture Agenda Items 6. Adjournment I, Shelley Major, City Secretary, do hereby certify that notice of the above meeting was posted on the front window of the City Hall of the City of Hudson Oaks, a place readily accessible to the public at all times, on the 8th day of April, 2015 at 5:00 p.m. and remained continuously posted for at least 72 hours preceding said meeting, and that said notice was posted in accordance with chapter 551 of the Texas Government Code. This facility is wheelchair accessible and accessible parking spaces are available. Requests for accommodations or interpretive services must be made 48 hours prior to this meeting. Please contact the city secretary at 682-229-2411 or email [email protected] for more information. Shelley Major City Secretary Planning & Zoning Commission Meeting Agenda for April 14, 2015 Page 1 of 1 City Council Meeting Staff Agenda Report Parliamentary procedure review Meeting date: April 14, 2015 Agenda Item #: Workshop, Item 1 Action being considered: None Staff Recommendation: No action necessary. Prior Board or Council Action: None. Background Information/Analysis: By request of Chairman Carter, a review of parliamentary procedure will be presented by the City Secretary. This presentation will give an overview of meeting procedure, with a focus on motion procedure and public hearings. The Planning and Zoning Commission meetings are conducted following the Texas Open Meetings Act and Roberts Rule of Order. New members receive a brief overview of meeting procedure during orientation. The P&Z regular session will follow immediately after this workshop item. Attachments: None Staff Contact: Patrick Lawler, city administrator 682-229-2408 [email protected] Shelley Major, city secretary 682-229-2411 [email protected] 1 City Council Meeting Staff Agenda Report Consideration of Planning & Zoning Commission minutes for March 10, 2015 Meeting date: April 14, 2015 Agenda Item #: 3 Action being considered: Adoption of March 10, 2015 Minutes Staff Recommendation: Review and adopt the minutes of the March 10, 2015 Planning & Zoning Commission meeting. Prior Board or Council Action: Board has not previously acted on this item. Background Information/Analysis: Meeting was held at 7:00 p.m. on Tuesday, March 10, 2015 at Hudson Oaks City Hall. Attachments: DRAFT Minutes for March 10, 2015 Staff Contact: Patrick Lawler, city administrator 682-229-2408 [email protected] Shelley Major, city secretary 682-229-2411 [email protected] 1 MINUTES PLANNING & ZONING COMMISSION REGULAR MEETING TUESDAY, MARCH 10, 2015 STATE OF TEXAS COUNTY OF PARKER 1. § § § MEMBERS PRESENT: Chairman Tim Carter Vice-Chair Dale Wilkins Commission Member Jo-Alice Davis Commission Member James Gibbens Commission Member Jim Jones arrived at 7:29 p.m. Commission Member Matthew Judy Commission Member Jan Parker MEMBERS ABSENT: None STAFF PRESENT: Patrick Lawler, City Administrator Chad Janicek, Assistant City Administrator Shelley Major, City Secretary Call to order/announcement of quorum With a quorum present, the Regular Meeting of the Planning & Zoning Commission was called to order by Chairman Tim Carter at 7:02 p.m. on Tuesday, March 10, 2015, in the Council Chamber, Hudson Oaks City Hall, 210 North Lakeshore Drive, Hudson Oaks, Texas, 76087. 2. Citizen Comments No citizen comment. 3. Consideration of Planning & Zoning Commission minutes for February 10, 2015. ACTION: Motion made by Commission Member Wilkins and seconded by Commission Member Parker to approve the Planning & Zoning Commission minutes for February 10, 2015. The motion passed unanimously (5-0). 4. Public Hearing and discussion/recommendation on approval to create a Zoning Overlay District being 9.361 acres of land in the Oakridge Addition, Lots 6-9, Block 7, and Lot 1, Block 6, Hudson Oaks, Parker County, Texas. Chairman Carter opened the public hearing at 7:14 p.m. Terry Wysoy, 3115 Oykey Trail, is for the zoning. Mr. Wysoy asked for clarification on the two-way traffice on Midway Drive. He stated that he would probably sell his property depending on the development. Mr. Wysoy also asked for clarification on the parking lot lighting. He said he wants the community, that he has lived in for fifteen years to grow. He also had questions regardgin the redevelopment of sidewalks and widening the street. Angel Sanchez, 3115 Oykey Trail, has mixed feelings about the zoning, he is concerned about being forced out of home. Chairman Carter closed the public hearing at 7:33 p.m. ACTION: Motion made by Commission Member Davis and seconded by Vice-Chair Wilkins to recommend approval of the Planned Development Oykey Corridor, with the inclusion of language to clarify consistency of signage in Item D, Section 12. The motion passed, (6-0). 5. Future agenda items No future items. 6. ADJOURNMENT There being no further business, Chairman Tim Carter adjourned the Regular Meeting of the Planning & Zoning Commission at 7:36 p.m., on Tuesday, March 10, 2015. ________________________ Tim Carter, Chairman ATTEST: _______________________ Shelley Major, City Secretary Planning & Zoning Commission Regular Meeting Page 2 of 2 Planning and Zoning Commission Staff Agenda Report Presentation and discussion regarding Accessory Building Regulations Meeting date: April 14, 2015 Agenda Item #: 4 Action being considered: None Staff Recommendation: None Prior Board or Council Action: Board Member Jo-Alice Davis requested the Board review the current accessory building regulations. Background Information/Analysis: The accessory building regulations are generally written to allow both the construction of accessory buildings, detached garages, and workshops. “An accessory building is a subordinate building detached from the main building, without sleeping areas or kitchen facilities, not used for commercial purposes, not rented, and not occupied for human habitation, except as otherwise allowed by city ordinance. No accessory building shall be constructed until a main building exists on the lot.” Items for Review: 1. A clear conflict exists within the regulations concerning the difference between storage, workshop, or detached garages. Most permits applicants apply under the storage building provisions due to the reduced level of construction required (metal vs. masonry). The ordinance does not provide a definition to distinguish the difference between storage buildings and detached garages. Staff generally interprets that a building built directly adjacent to attached garages, in and around the existing driveway as a detached garage. Otherwise, if the building is built deep on the lot with a roll up or garage door and the applicant specifies the building is for storage, detached garage provisions are not required to be followed. Thus, the applicant can build up to 640 square feet of metal/composite building without matching the homes masonry content. 2. For residents wishing to construct a detached garage, other accessory buildings must be removed from the lot prior to permit approval. However, if a resident builds a storage building, two buildings may exist as long as the total square feet of both buildings is less than 640 square feet. The wording of the ordinance encourages construction of metal buildings over masonry structures. 1 Planning and Zoning Commission Staff Agenda Report 3. The allowed size of permitted storage buildings built to a metal or composite standard is 640 square feet. The typical size of a two car garage is between 400 and 480 square feet. Attachments: Accessory Building Regulations Staff Contact: Patrick Lawler, city administrator 682-229-2408 [email protected] Shelley Major, city secretary 682-229-2411 [email protected] 2 Planning and Zoning Commission Staff Agenda Report Section 28 28.1 Accessory Buildings General Purpose and Description An accessory building is a subordinate building detached from the main building, without sleeping areas or kitchen facilities, not used for commercial purposes, not rented, and not occupied for human habitation, except as otherwise allowed by city ordinance. No accessory building shall be constructed until a main building exists on the lot. 28.2 Accessory Building Regulations The following regulations shall govern the location, size and use of accessory buildings, except for barns and farm buildings for agricultural uses as defined in Section 48.2 and accessory buildings for airpark related uses as defined in Section 49: A. General Provisions: An accessory building must comply with the following setback requirements for all zoning districts: 1.) Accessory buildings shall not be located within any easement. 2.) Accessory buildings may not be placed so as to negatively impact drainage on any adjacent lot by diversion or impoundment of storm water flows. 3.) Accessory buildings located on lots where septic systems are utilized must submit a site plan showing the layout of the septic system and the location of the proposed building. 4.) Approval by the City of Hudson Oaks does not constitute approval to violate any deed restriction. It is the responsibility of the applicant to verify compliance with all deed restrictions for his or her property, before starting construction. 5.) No accessory building shall be used for dwelling purposes other than by domestic servants employed on the premises, as stipulated in Section 11, Permitted Use Table. 3 Planning and Zoning Commission Staff Agenda Report 6.) Residential greenhouses for domestic use shall not exceed 500 square feet of floor area. 7.) All single-family dwellings hereafter erected shall be provided with enclosed garage space for at least parking two automobiles at the time of original construction. Conversion of garage space into living space shall conform to City building codes; and plans for the conversion shall be submitted at the time of application for a building permit. Conversion of garage space does not relieve the requirement for an enclosed garage space, and said enclosed space must be provided elsewhere on the lot and in compliance with this section. 8.) Accessory buildings six hundred forty (640) square feet or less may be constructed of metal, if the metal building is an engineered metal building. The exterior of the building must be a neutral, earth tone color such as Mueller light stone or Mueller desert tan. The side panel must be a “U” Panel or an “R’’ panel type, or an alternative panel type authorized in writing by the City Administrator. Corrugated panel types are not permitted. The color and materials of the roof of the accessory building must closely resemble the color and materials of the roof of the main building. Any exterior door or roll up door shall be painted in a complimentary neutral earth tone color. B. Building Construction and Setback Requirements: For each zoning district, an accessory building must comply with the following construction and setback requirements: Exterior Wall and Roof Type Legend Classification Exterior Wall Roof A The color and materials of the roof of the accessory building must closely resemble the color and materials of the roof of the main building. Exterior grade wood siding, metal, stone or masonry. 4 Planning and Zoning Commission Staff Agenda Report B Must have exterior walls that are at least the same masonry content required of the main structure. The masonry used on the accessory building shall closely resemble the masonry used on the main buildings. The color and materials of the roof of the accessory building must closely resemble the color and materials of the roof of the main building. Portable or Storage Buildings Zoning District Maximum Number of Units* Exterior Wall Type Roof Type 320 sqft 2 or 1 A A SF-32 640 sqft 2 or 1 A A SF-1AP 160 sqft 1 A A SF-2S 640 sqft 2 A A MF Not Allowed Not Allowed - - MH 160 sqft 1 A A SF-15 Maximum total size (all units) * For the SF-15 and SF-32 zoning districts, if the lot will also have a detached garage or workshop, then the Maximum Number of Units for a Portable or Storage Building is reduced by half. Detached Garage or Workshop Zoning District Maximum Number of Units* Exterior Wall Type Roof Type 400 sqft 1 B B SF-32 1,000 sqft 1 B B SF-1AP Not Allowed Not Allowed - - SF-2A 1,500 sqft 1 B B MF Not Allowed Not Allowed - - SF-15 Maximum total size (all units) 5 Planning and Zoning Commission Staff Agenda Report MH Not Allowed Not Allowed - - * For the SF-15 and SF-32 zoning districts, if the maximum number of units allowed for Portable or Storage Buildings currently is constructed on the lot, then a Detached Garage of Workshop is not allowed unless a Portable or Storage Building removed from the lot. Required Setbacks An accessory building must comply with the following setback requirements. 1.) Rear Yard – The accessory building must be located at least three (3') from the rear property line, easement, or right-of-way. Where accessory buildings are designed and constructed to be entered from an alleyway or street at the rear of the lot, such accessory building shall be setback at least twenty (20') feet from the rear property line. When accessory buildings are constructed less than five (5') feet from any property line, no windows, doors or other penetrations of the exterior wall shall be allowed in the wall abutting that property line. In Single-Family 2-A (SF-2A) zoning districts, barns and/or stables shall not be located within fifty (50') feet of any property line. 2.) Side Yard – Accessory buildings shall be set back a minimum of three (3') feet from an interior side property line. Where accessory buildings are designed and constructed to be entered from an alleyway or street at the side of the lot, such accessory building shall be setback at least twenty (20') feet from the rear property line. When accessory buildings are constructed less than five (5') feet from any property line, no windows, doors or other penetrations of the exterior wall shall be allowed in the wall abutting that property line. In Single-Family 2-A (SF-2A) zoning districts, barns and/or stables shall not be located within fifty (50') feet of any property line. 3.) Front Yard – Accessory buildings shall not be located in the front yard. 6 Planning and Zoning Commission Staff Agenda Report 4.) Buildings – Accessory buildings shall be located at least ten (10') feet from any other building or structure on the property. C. Building Construction: All accessory buildings must comply with the following construction requirements: 1.) Foundations – Foundation requirements for accessory buildings are as follows: Buildings up to and including 160 square feet may be placed on the ground and shall provide resistance to wind load by one of the following methods: a. Anchored to a four (4") inch thick slab reinforced with 6 X 6 #10 wire mesh or #3 (3/8") rebar spaced at 18 inches on center each way. b. Anchored at all corners, each corner anchored by a system to resist a horizontal wind load of 75 miles per hour Buildings greater than 160 square feet, but less than 639 square feet shall use one of the following methods: a. Beams must be constructed at all perimeters. All beams are required to be at least 10 inches wide and 20 inches deep with 2 #5 (5/8") bars in the top and 2 #5 (5/8") bars in the bottom of the beam. Interior beams must also be constructed and located no more than 12 feet apart. All beams must extend at least 12 inches into undisturbed soil. Place #3 (3/8") bars 18 inches on center each way in the middle of the new 4-inch slab. Accessory buildings greater than or equal to 640 square feet shall use a foundation designed by a registered professional engineer in the State of Texas to the current City of Hudson Oaks building code requirements. 7 Planning and Zoning Commission Staff Agenda Report 2.) Eave Height and Pitch – Accessory buildings shall have an eave height no greater than the lowest eave height of the primary building, but not to exceed 14' feet. The roof shall be at a pitch similar to the roof pitch of the primary building. 8
© Copyright 2024