AUS LUXOMAT ® PD3-2C Micro Installation and Operating Instruction for B.E.G. - Motion detectors PD3-2C-FC Micro 1. Mounting preparations 2. Installation of the LUXOMAT® PD3-2C-FC Micro Work on the 230 V mains supply may only be carried out by qualified professionals or by instructed persons under the direction and supervision of qualified skilled electrical personnel in accordance with electrotechnical regulations. 68 mm The detector has been designed and developed specifically for installation in suspended ceilings. Having connected up the cables in accor dance with regulations, the detector is inserted into the opening as shown in the drawing above and fixed into position with the assistance of the spring clips. 5. Putting into operation / Settings 5 10 20 TEST Potentiometer 1 - Follow-up time for light control The time can be set infinitely variably at between 15 seconds and 30 minutes. ymbol TEST: Test mode S (Every movement switches on the light for a period of 1 second, switching it off for a period of 2 seconds after that regardless of the level of brightness.) 30 Potentiometer 2 - Adjusting range sensitivity max. For sensitivity adjustment of the detector, both in the min. 120 60 50 A 40 30 15 5 10 40 50 30 60 16 10 15 5 90 10 2 5 120 1 TEST 15 30 2000 1200 600 200 40 interior and the exterior range, the PD3-2C-FC Micro is equipped with an additional knob (see pictures) for excluding sources of interference, e.g. bad weather conditions or draught air. Max:for interior use (recognition of the slightest movements) Min:for exterior use (exclusion of sources of interference) Potentiometer 3 - Follow-up time for HVAC The time can be set infinitely variably at between 5 and 120 minutes. There is a period of delay prior to switch-on at between 5 - 10 minutes for times set in excess of 60 minutes. Potentiometer 4 - Twilight-switch for light control The switch-on value for the light can be set at between 10 and 2000 Lux. Using the rotary control, the luminance set points can be set as desired. Symbol : Night-time operation Symbol Position potentiometers 4. Connections 5 4 1 2 3 A circular opening of diameter 68 mm must be cut into ceiling. Disconnect supply before installing! 1 30s 15s 3. Hardware configuration N R L‘ L Potentiometer 1 Time channel 1 2 Range 3Time channel 2 4 Lux channel 1 5 Sound sensitivity 6. Technical data PD3-2C 7. Trouble shooting Sensor and power supply in one case Power supply: 230 V~ ±10 % Power consumption: < 1W Ambient temperature: -25°C to +50°C Degree of protection /class: IP20, with accessory IP23 / II Settings: locally Area of coverage: circular 360° Range of coverage Ø H 2.50 m / T = 18°C: seated 4 m / tangential 10 m / radial 6 m Recommended height for mounting: 2 - 3 m Lux values - Potentiometer: 10 - 2000 Lux • Channel 1 for light-connection Type of contact: NOC/with pretravel tungsten contact Contact load: 2300 W, 230 V~, cos ϕ=1 / 1150 VA cos ϕ= 0.5 Time-settings: 15 sec. - 30 min. / Test • Channel 2 for HVAC Contact load: 230 V~, 3 A cos ϕ=1 Time-settings: 5 min. - 120 min. with time delay of 5 - 10 min. for follow-up time > 60 min. Dimensions H x Ø [mm] 84 x 80 Visible portion when built into ceiling: 18 x 80 mm 1. Lamp does not light up Declaration of Conformity: The product complies with the low voltage recommendation 2006/95/EC and the EMV recommendation 2004/108/EC. LUXOMAT® PD3 connected in parallel to a manual override switch: Connect switch correctly Lamp may be defect: Replace lamps No mains connection/power: Check connection and mains fuse by qualified electrician Incorrect setting of CDS twilight threshold: Correct setting of CDS threshold Lens of sensor unit obstructed by dirt or other objects: Clean lens, remove objects 2. Lamp turns ON too late or detection range too small LUXOMAT® PD3 is mounted too high: See table of mounting heights. Correct mounting if required. 3. Lamp stays ON continuously Continuous thermal activity detected ie fan, central heating ducts, animals within detection area: Remove heatsource. Check proper function of LUXOMAT® PD3 by covering the fresnel-lens. After expiry of delay timer, PD3 has to turn OFF lighting. 4. Unintended switching of light Movement of heat source within detection area: Check on presence of animals, fans or heaters : Daytime / Night-time operation Potentiometer 5 - Adjusting sound sensitivity max. Max: highest sensitivity Min:microphone switched off Intermediate values to be adjusted accordingly to local conditions.������������������������������������� ������������������������������������ Lighting of the LED means the noisedetector is functioning and triggers the timer again. The microphone is active for 9 seconds after the last movement and time delay completed. min. 8. Range of Coverage 9. Article / Part nr. / Accessory 2.50 m Type FC PD3-2C Micro 96510 Accessory: BSK Ball basket guard FC-Covering IP23 3 10 m 2 1 360°0 m 4.0 1 2 R2: 3A NO 230 VAC ±10% 50-60 Hz quer zum across Melder gehen walking frontal zum Melder gehen walking towards Unterkriechschutz seated 6m 10 m 92199 92206 10. Wiring diagrams 12. PD3 - Dimensions 3A 5 15 M1 E1 230VAC 50-60Hz 7m ~6 m T1 R L' N L L NO NO Slave / Remote 84.5 6m 5 74 L N 64 Standard mode with slave device 13. Installation examples R N L L΄΄ NO NO C1 R C2 N L 18 m PD3-2C Micro Slave 6m optional T1 = Light ON/OFF (see point 14 also) Slave for enlargement of detection area 11. LED function displays ~6 m 6m 2000 Lux 1 1200 2 600 200 40 12 m LED’s 1 - Red flashes on each detected sound 6m 4m 2-R ed - flashes 60 sec. during initialisation period - flashes on each detected movement - flashes quickly, if duration “ON” active by terminal R 6m 6m 14. Functions of pushbutton The table below shows the logical behavior of both channels (light + HVAC). Brightness-state 230 VAC on Terminal R Channel 1 for light-connection Channel 2 for HVAC bright no change no change 1-2 sec. (slave signal) > 10 sec. OFF -> ON or ON -> OFF no change (as long as motion + Follow-up time ) no change OFF -> ON OFF -> ON getting dark release button OFF -> OFF OFF -> ON will stay-on (as long as motion + Follow-up time) dark no change no change 0-1 sec. or 2-10 sec. 1-2 sec. (slave signal) > 10 sec. Release button will stay-on (as long as motion + Follow-up time) OFF -> ON or ON -> OFF no change (as long as motion + Follow-up time ) OFF -> ON OFF -> ON OFF -> ON will stay-on (as long as motion + Follow-up time) OFF -> ON will stay-on (as long as motion + Follow-up time) When a channel or slave-hold (pushbutton > 10 sec.) gets deactivated, it is possible to reactivate the channel by sound/motion for 10 sec. This possibility is independent of brightness-state. So even if the lightchannel is in bright condition. (light level > setpoint) MAN 6891– 090511-1 0-1 sec. or 2-10 sec.
© Copyright 2024