600 XLE - innova

600
XLE
USER MANUAL
THE FUTURE IS MOBILE
Comfortably
Sitting and lying:
Perfect Results
SURGERY CHAIRS FOR PROFESSIONALS
600 XLE
www.ufsk-osys.com
Manfactured by:
ufsk-international osys gmbh
Kirchhoffstr. 1
93055 Regensburg
Germany
phone
fax
e-mail web
+49 (0) 941 78862-0
+49 (0) 941 7886218
[email protected]
ufsk-osys.com
phone
fax
e-mail web
+49 (0) 941 78862-0
+49 (0) 941 7886218
[email protected]
ufsk-osys.com
Service provided by:
ufsk-international osys gmbh
Kirchhoffstr. 1
93055 Regensburg
Germany
Distributor:
Ser. Nr.:
UFSK-OSYS
THE FUTURE IS MOBILE
600 XLE
User-Manual
Thank you for choosing our surgery
chair 600 XLE. Our illustrated
service manual is supposed to be a
detailed assistance to all daily use
questions.
Nevertheless, should you have any
further questions, please do not
hesitate to contact our technical
service or send us an e-mail:
[email protected]
UFSK-OSYS
Content
General
6
Putting into operation10
Emergency Stop11
Using the chair cover12
Programming the Memory Hand Control14
Undercover – Foot Keyboard15
Prepare for Operation16
Easy Steering22
Using the arm rests24
Unpacking26
Loading the Batteries27
Optimum Loading28
Flexibility29
Optional Accessories30
600 XLE
Tough, Solid and Flexible
Maximum load 175 kg
600 XLE
Noble chair – strong steel
Upper frame
ChromeNickelSteel
(CNS)
aluminum
Y-Chassis
It is particularly important to us to use high quality materials. For the upper frame we use
tempered steel. For the chassis we use light aluminium.
UFSK-OSYS
Seamless shaped upholstery
600 XLE
10
Putting into operation:
Keysetting/putting on
1
2
3
4
5
6
7
8
9
1. head up/down
2. back up/down
3. foot up/down
4. Reverse-/ Trendelenburg
5. total up/down
6.
7.
8.
9.
back/foot up/down
Memory position I,II,III,IV
breaking system
chair position
Press I/O right on the bottom to put the
chair on or off.
UFSK-OSYS
11
Emergency stop
By pressing the emergency stop button, the
total power supply is out of order. Before
starting, please release the red button by
turning it.
600 XLE
12
Using the Chair Cover
Aggressive, salty liquids
can adversely affect your
surgery chair on a longterm basis. We recommend our chair cover.
By using our chair cover,
your surgery chair and its
moving parts are perfectly
protected.
1) Place the chair cover with the marked
arrow upwards in the middle of the chair.
2) Fold back first on the
left, then repeatable from
inside to outside.
UFSK-OSYS
3) Put the hood over the head part.
13
4) Hang both side lashes into the rails at the
side of the chair.
5) Pull the cover completely down.
6) The intended openings are to be put over
the sliding handles.
7) A perfect chair cover that does not slip
and protects the chair of liquids and contamination.
600 XLE
14
Programming the memory hand
control
The four memory buttons (I-IV) are supposed to be for different memory positions.
The following positions are
pre-programmed:
I=transport position
II=anaesthesia position
III=OR position
IV= alternative OR position
Keep the button pressed until the final position is reached.
It is possible at each time to change the
complete memory position or just single
functions of it.
Keep the desired MEMORY (I-IV) pressed
and, at the same time, press the function
that has to be changed (e.g. seat down) until
the desired position is reached. Release the
button.
The hand control automatically saves the
new position, all remaining position stay the
same.
UFSK-OSYS
15
Undercover – Foot Control
Alternatively to the hand operating keyboard, the chair can be operated sterile by the operating
doctor via the undercover foot control. The function is released by touching the button in the
middle with your foot. The undercover foot control is detachable and has, of course, to be put on
again for manoeuvring.
Head up/down
Total up/down
600 XLE
16
Preparation for operating
Easy entry
Press the STOP button to lock the wheels.
UFSK-OSYS
Your patient now may take a seat.
17
Driving/Transportation
Keep the button MEMORY I pressed until
chair position is reached.
Choose your direction: direction head or
direction foot (see picture direction foot).
Press the button FOOT on the hand keyboard for directional adjustment of the foot
wheel. Diode lights orange.
By hand, the right foot wheel has to be
locked running after the person.
600 XLE
18
Preparation for operating
In this way the chair an be manoeuvred by only
one person even in narrow space.
For anaesthesia position
Keep the button MEMORY II pressed until anaesthesia position is reached.
UFSK-OSYS
19
Adjusting the head
For the individual adjustment of the head
part loosen the sticking device.
Furthermore, the head part can be moved or
tilted. Is the desired position reached, lock
the sticking device.
Correct the height of the head part via the
undercover foot control head up/down.
Prepare your patient.
600 XLE
20
Preparation for operating
Adjusting the OR position
Transport in the OR
Keep the button MEMORY III pressed until
the pre-programmed, individual position is
reached.
Push the chair forwards in the OR.
Press the button HEAD on
the hand control for directional adjustment of the head
wheel. Diode lights orange.
UFSK-OSYS
By hand, the head wheel
has to be locked running
after the person.
In this way the chair can be manoeuvred by only one person
even in narrow space.
21
Operating
NOTE:
Turn off
Press the STOP button to lock the wheels.
Press the I/O button and turn the chair off.
The chair is now ready for operation.
After the surgery
After the surgery switch on the
chair with I/0, and your patient
relaxes with MEMORY II.
Then drive into transport position
with MEMORY I.
For easy get on or get off the
chair push the chair button.
600 XLE
22
Easy steering:
At the head end
Generally, the wheel that faces the person pushing or pulling the chair should
be locked running after the driving direction.
Driving direction
No matter if you push...
Driving direction
or pull...
NOTE: The chassis facing the pushing or pulling is to be locked.
UFSK-OSYS
23
Easy steering:
At the footend
You push or pull at the foot end:
The marked wheels at the head end has to be locked according to the
picture and therefore running after the chassis.
600 XLE
24
Using the armrests
The armrest can steplessly be adjusted from one fixing point for each patient. Focussed is the
comfort for the patient and space advantage for the operating doctor. The Chrome-Nickel-Steel
mounting clamp is generally fixed at the shoulder part side rail.
The Chrome-Nickel-Steel bar is fixed in the mounting clamp from the underside and fixed
slightly. The sticking device of the armrest has always to be in direction of the user.
By loosening the turning device, the armrest
can be moved in length.
UFSK-OSYS
25
By loosening the sticking device, the armrest
can be adjusted around in any position.
By loosening the turning device, the armrest
can be turned to the outside.
In this way, any position can be adjusted at
the shoulder part without needing to much
space.
600 XLE
26
Unpacking
The UFSK-OSYS surgery chairs are packed solid, safe and
stable for worldwide shipping.
UFSK-OSYS
27
Loading the batteries
The chair has integrated accumulators for working without direct
power supply.
The chair has an optical loading control on the hand keyboard (five
green LEDs). When the chair is fully loaded, all LEDs light green.
The LEDs turn off one after another the more the chair is used. The
chair has to be loaded regularly.
Open the cover of the socket with your left hand. At the same time, connect the plug with the
charge jack accordingly. Now the plug has to be connected with a conventional socket.
Prove at the green control lamp if the chair is loaded.
600 XLE
28
Optimum Loading
The accumulators are made of lead-gel and do not show a memory effect anymore.
The hand control unit has a loading control lamp. If all five green diodes light up, the
accumulators are loaded up 100%.
The chair should be loaded again when at least three diodes
do not light up anymore. Please note that loading has been
completely finished before working with the chair starts again.
Loading is made with increased loading power for fast loading. An additional control unit protects the accumulators of
overloading, nevertheless, cannot guarantee the prevention
from overloading.
A total loading circle takes generally 8 hours.
The loading circle should not extend 12 to 15 hours as too long loading can damage the accumulators in the long run despite overloading protection.
UFSK-OSYS
29
Flexibility
Continuously variable motors for head, back, seat and leg part
600 XLE
30
Optional Accessories
Create your individual surgery chair with several accessories, e.g. head adjusting
pillow with hollow, click-off-holder or shock absorber.
Click-off-holder for hand control
keyboard, flexible (order together with
clamp 0120)
0180
Arm rest with cardan joint adjustable,
lockable, including mounting clamp CNS
0110
Click-off-holder fixation for
monitor arm 0240
Drape support, flexible
(order together with clamp
0120)
0270
0320
Drape support, flexible with oxygen
connection
(order together with clamp
0120)
Lateral shock absorber, PVC, pair
0380
0330
Head adjusting pillow with hollow,
leather, seamless shaped, with radius
0210
Monitor arm CNS, to be swung including
telescopic infusion suspension bar
0240
Shock absorber for head part, CNS
Cover drape BL 600 XLE/ BL 500 XLE
0460
0280
Hand support ring with fixation plate
CNS, height adjustable, arrestable with
upholstery
0140
Head adjusting pillow with hollow,
square, seamless shaped
(rubins pillow)
Knee support cushion
0190
Hand secure bands, pair
0220
Shoulder parts, pair
Body strap
0430
UFSK-OSYS
0150
0230
31
Protection foil transparent, removable
0300
Foot step with castors, at the same time
extension of the foot part
0420
Lateral parts/body support,
inside with removable upholstery
(540x185x15mm), pair
Mounting clamp, Chrome-Nickel-Steel
(CNS)
0260
Mounting clamp aluminum
0120
Sliding blocks, plastic, pair
0440
-0290
Infusion suspension bar with hooks,
telescopic
(order together with clamp
0120)
0170
Surgery chair
3030-010
3014-010
Upholstery available in different colors
see color configurator on our website: www.ufsk-osys.com
600 XLE
32
THE FUTURE IS MOBILE
© 04/2006 Copyright ufsk international osys GmbH Germany
Printed in Germany
UFSK-OSYS.com
600XLE