li ndab | ceiling diff users - v isible Visible diffuser LCF Dimensions H Ød1 A 1 2 ØA 3 B 4 5 Description LCF is a diffuser with circular unperforated face plate for free hanging installations. LCF is suitable for horizontal supply of cooled air and handles high airflows as well as low airflows with high undertemperature without the risk of drafts. LCF includes a unique linear cone damper which makes it possible to regulate in the full airflow range (0-100%) and allows to balance with a high pressure drop over the unit with low sound level (up to 200 Pa). 6 Ød1 mm ØA mm A mm H mm B mm Weight kg 125 460 80 241 250 7,00 160 540 97 275 300 10,0 7 8 Construction 9 Furthermore the construction of the damper gives an accurate and reliable measurement. LCF has a readable K-value scale and has the possibility to be preadjusted before the final balancing. 10 • Suitable in full airflow range with high under temperature • Unique linear cone damper • Up to 200 Pa with low sound level • Accurate and reliable measurement of flow 11 12 Maintenance The face plate can be detached and the damper removed to enable cleaning of the internal parts or the duct. The visible parts of the diffuser can be wiped with a damp cloth. 13 14 15 Materials and finish Material: Standard finish: Standard colour: Order code Product Type Size Functional use LCF bbb S Galvanised steel Powder-coated White, RAL 9010, gloss 30 or white 9003, gloss 30. The diffuser is available in other colours. Please contact Lindab’s sales department for further information. We reserve the right to make changes without prior notice 2015-04-10 16 17 18 1 lindab | ceil ing di ffusers - vi sible Visible diffuser LCF Technical data 1 2 3 4 Capacity Volume flow qv [l/s] and [m3/h], total pressure Δpt [Pa], throw l0.2 [m] and sound power level LWA [dB(A)] can be seen in the diagrams. Frequency-related sound effect level The sound effect level in the frequency band is defined as LWA + Kok Kok values are given in charts beneath the diagrams on the following pages 6 7 The throw is specified at a terminal velocity of 0.2 m/s. l0.2 [m] 10 LCF 125 160 7 6 5 4 3 Quick selection 5 Throw l0.2 2 Supply air l0.2 [m] Δpt ≥ 50 Pa Δpt ≥ 50 Pa 30 dB(A) 35 dB(A) duct 1 15 Ød1 l/s m3/h l/s m3/h 125 55 198 71 256 160 76 274 99 356 20 60 30 80 100 40 50 150 60 200 80 100 300 150 500 200 700 300 1000 qV [l/s] qV [m3/h] Sound attenuation Sound attenuation of the diffusers ΔL from duct to room, including end reflection, see table below 8 Centre frequency Hz 9 10 Size 63 125 250 500 1K 2K 4K 125 16 9 12 8 10 11 16 21 160 13 9 11 6 9 8 15 20 Balancing Balancing data is contained in a separate brochure. 11 12 13 14 15 16 17 18 2 We reserve the right to make changes without prior notice 2015-04-10 8K li ndab | ceiling diff users - v isible Visible diffuser LCF Technical data 1 Δpt [Pa] LCF-125 250 200 2 50 150 45 100 40 3 70 35 50 30 30 25 20 4 20 15 LWA dB(A) 10 5 q [l/s] 10 15 20 30 40 50 60 70 100 150 V q [m3/h] 40 50 60 70 100 150 200 300 400 500 Hz 63 125 250 500 1K 2K 4K 8K Kok 7 7 -3 -6 -4 -8 -15 -17 V 6 7 Δpt [Pa] LCF-160 250 200 150 8 50 100 45 40 70 9 35 50 30 30 25 20 10 20 15 LWA dB(A) 10 10 15 40 50 20 30 100 40 50 150 60 200 80 100 300 150 400 500 200 60 80 700 Hz 63 125 250 500 1K 2K 4K 8K Kok 10 9 -3 -6 -4 -10 -16 -14 qV [l/s] qV [m3/h] 11 12 13 14 15 16 17 18 We reserve the right to make changes without prior notice 2015-04-10 3
© Copyright 2024