Aicure LED Line Type UV Curing Systems UD 40 Series Controller Installation Manual Thank you very much for purchasing the UD40 Series Line Type UV Curing Systems. Be sure to read this installation manual first and install this product properly. Keep this manual in a safe place after reading this and look it up as needed. Safety Precautions Please use the following precautions to prevent injuries and accidents. Power Supplies Warning Do not use this product in an environment containing flammable gas. Doing so may cause an explosion. Do not throw this product into fire. Prohibited Doing so may cause the electrical components to explode. Never look into the direct light or its reflection or expose your skin to such light while the LED is turned ON. Doing so may harm or irritate your eyes and skin. Install this product at a place where the human body will not be exposed to the LED-UV light. Be sure to observe Being exposed to LED-UV light may harm or irritate your skin. When a human body is in danger of being exposed to the LED-UV light or reflected UV light, cover the light with an enclosure with appropriate permeability and heat characteristics to block the UV light. Be sure to wear protective glasses and protective gears when installing or operating this product. Doing so without them may harm or irritate your eyes and skin. The light emitted from this product includes UV light of 365nm or 385nm wavelength. Make sure to wear protective glasses to block the UV light. Make sure to shut off the power supply when cleaning the LED head. Doing so without shutting off the power supply may harm or irritate your eyes and skin, or may result in electric shocks. Do not disassemble or alter the product. No disassembling Doing so may result in accidents, injuries, or electric shocks. Doing so may result in abnormal heating or fuming. Doing so may harm or irritate your skin by being exposed to LED-UV light. Caution Supply single phase 200 to 240V (frequency of 50 to 60Hz) as the supply voltage. Customers must prepare the power cable (AC supply cable) of the diameter appropriate for the maximum input current. Securely connect the power cable to the terminal block (screw diameter ø4) on the back of the control unit. Connect the ground wire securely. Do not share the power line between this product and a motor, machine with induction property, or device that consumes large amount of power. The controller is sufficiently resistant to noise superimposed on the power line. However, we recommend using an isolation transformer or similar device to attenuate noise before supplying power. Wiring Use the supplied cables for the connections among the control unit, power unit, and LED head. Make sure that the cables are connected securely. When connecting cables to D-Sub37 connector for the external I/O, accurately solder them to the connector to prevent a short circuit between terminals. When connecting an inductive load (motor or relay) to the external I/O, connect a noise absorber (noise killer, etc.) to the load side. After finishing the connections of the power cable, securely screw the terminal block cover to prevent an electric shock. Hold the connector (plug) area when connecting/disconnecting the cables. Wire the cables so that extra load is not applied to the cables and connectors. Installation Install rubber feet on the horizontal surface. The product must not be installed in a way of being tilted, laid on its side and placed upside down. It may be heated and damaged. Doing so may result in abnormal heating or fuming. Do not install the product in an enclosed space. Do not block the ventilation hole of the power unit. Make sure to take safety measures (such as an interlock or smoke detector installation) externally so that a fail-safe mechanism works in the entire system in case of a system failure or an error caused by external factors. Doing so may result in electric shocks. Verify that all the wiring and connections are correct before turning on the power. Prevent any foreign materials, including liquid, flammable materials and metals, from entering into this product. Prohibited Installation Environment Ambient Temperature 0 to +35ºC Ambient Humidity 30 to 85%RH (Without dew condensation and freezing) A place free from dust, oil smoke, conductive dust, corrosive or flammable gas, salt content or iron dust. A place free from splashes of water, oil or chemicals. A place free from sudden temperature changes, oscillation or shocks. A place without direct sunlight. A place without high magnetic field or intense electric field. Do not perform any installation work (such as connecting or disconnecting) with the power turned ON. Avoid placing any object on this product or block the ventilation hole. Doing so may result in burnout by heating. Do not touch with bare hands immediately after irradiation and during irradiation. Before Turning On the Power 3 Connections System configuration This product becomes very hot and may cause burn injuries. Use this product in a condition sufficiently under the threshold guaranteed or specified. Exceeding the threshold of the characteristics/performance guaranteed may damage the product. Be sure to observe LED head AC power supply Ground Control unit Do not touch the terminal while the power is being supplied. Doing so may result in electric shocks. Securely connect the power line and the connector. LE Improper connection may result in abnormal heating or fuming. Dh Do not use input power outside of the specified range. Doing so may result in burning out. Connect the ground wire securely. ea Power unit Doing so may result in electric shocks or malfunctions. dc on ne ctio nc Do not use this product in a place where the temperature changes drastically or a dew condensation occurs. Po (A wer C su cab pp le ly ca b ab le le) Doing so may result in a malfunction. Do not use this product at a place where extreme vibration or shock is applied. Doing so may result in a malfunction. Ex ter 1 Included Items Control unit Power key: 2 D-Sub37 connector for external I/O wiring: 1 HDCB-37PF(05)(Hirose Electric Co., Ltd.) Power unit Signal cable: 1 (Cable length of approx. 1m) AC connection cable: 1 (Cable length of approx. 1m) LED head connection cable: 1 (Cable length of approx. 5m) Consider the followings when installing and using this product. Standard on the safety of LED products Note: Depending on the connected LED head configuration, multiple power units may be necessary. na l I/O na lc ab le nn ec tio nc co ab le 4 Dimensions Unit: mm Dimensions and Installation Space 50 or more 280 50 or more 50 or more Control unit 560 100 or more 497.4 40 160 or more <Reference: Standard on the safety of laser products> Standard : JIS C6802:2011, IEC60825-1 Edition2.0:2007 Class : Class 4 LED product Wavelength : 365±10nm, 385±10nm 201.2 UV Power unit 50 or more 280 (21) LED light source that is used in this product, has become the scope of application of the “Photobiological safety of lamps and lamp systems” Standard : JIS C7550:2011, IEC62471:2006 Class : Risk Group 3 However, we recommend a safety management in consideration for the safety of the user, corresponding to the Class 4 “Standard on the safety of laser products” AC 50 or more 50 or more 2 Precautions on Installation Sig Terminal block cover 200 or more 326 200 or more 280 Handling of LED Products at Overseas Currently, in JIS and IEC, LED is ordered to exemption of “Standard on the safety of laser products”. However, since you may be adopting the old edition depending on the country or region, please check the laser safety regulations and standards of the country to be used. (21) General Precautions Cables connected to this product, please use the products by our company designation or recommended. Any malfunctions and damages occurred from use of the other products are not covered by the product warranty. Do not disassemble, remodel the camera or change its internal settings. Any failure or damage arising out of using the disassembled or altered product will not be covered by the warranty. Do not install the control unit and power unit in an enclosed space. Please have a margin to installation space, and do not allow the exhaust air from the fan to enter through the air intake. D-Sub37 connector pin assignment (OUTPUT) 5 Part Names and Functions No. Signal name 29 Equipment power ON Control unit Back 8 7 30 31 32 33 34 35 36 37 5 2 1 6 3 Name ① Circuit breaker ② Pilot light ③ Key switch ④ Touch screen ⑤ Emergency stop switch 9 10 11 Function AC power is supplied to the equipment. When AC is supplied and the breaker is on, the light stays on. The equipment can be started or stopped. Each setting and display are available. This starts an emergency stop and stops UV radiation. To recover from an emergency stop, follow instructions provided on the touch screen. ⑥ Radiation switch/ Radiation light This switch starts or stops UV radiation in manual mode. During UV irradiation, red light stays on. ⑦ AC supply connector The connector allows AC power to be supplied to the power unit. (The number of connectors depends on the LED head configuration.) ⑧ Power unit communication connector The connector allows communication with the power unit. (The number of connectors depends on the LED head configuration.) ⑨ External I/O connector ⑩ Grounding terminal ⑪ AC power receiving terminal This connector allows external devices including PLC to be connected. Terminal for ground wire connection (screw diameter of terminal block: ø4) Terminal for 200 to 240V connection (screw diameter of terminal block: ø4) Power unit Front Back 8 Description ON※3 at equipment switch-on (ON※3 remains when an error occurs.) ON※3 when LED radiation available (OFF※4 when radiation from all LED radiation ready blocks are in progress or an error occurs) During LED Radiation ON※3 during LED radiation (OFF※4 only when all blocks are off.) ON※3 when LED or fan reaches end of life alert status Alert Occurrence of equipment error OFF※4 at occurrence of equipment error Equipment main unit emergency stop OFF※4 at an emergency stop of equipment main unit Reserved Reserved for output-1 Reserved Reserved for output-2 Common for Nos. 29 to 36 signals (for output) Common output ※1 Short circuit between the pin and common input pin ※2 One-shot pulse in which short circuit between the pin and common input pin is 0.3 sec or longer ※3 State of short circuit between the pin and common output pin ※4 State of open circuit between the pin and common output pin Note: The pins Nos. 27 and 28 are not connected. (unused) Input and output specifications Input specifications INPUT Internal circuit Front 4 24V COM <Connection example> Open collector Relay contact INPUT COM Rated input voltage: 24V DC Output specifications OUTPUT 13 Output type: Relay contact output Maximum rated voltage: 30V DC Maximum rated current: 1A DC Internal circuit 5 COM 14 12 16 Name 15 17 Function Air intake for cooling the power unit. The anti-dust filter is inside the panel. ⑫ Air intake Exhaust opening for discharging heat produced inside the power unit. The LED head is connected. The connector allows communication with the control unit. The connector allows AC power to be received. The connector allows AC power to be supplied to the second power unit. ⑰ AC power transmission connector (Depending on the LED head configuration, the second power unit may not be provided.) ⑬ Exhaust port ⑭ LED head connection connector ⑮ Power supply communication connector ⑯ AC power receiving connector 6 External I/O connector When connecting cables and connecting/disconnecting the connector, be sure to turn off the power supply to the main unit. Appropriate cable size: AWG#20-28 (Customers must prepare required cables.) Make sure to solder cables to the connector properly. See the official website or the catalog of Hirose Electric Co., Ltd. for details on soldering onto the connector and its handling. D-Sub37 connector pin assignment (INPUT) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Signal name Local/Remote selection LED lighting-1 Program No. change pulse Program No. bit-0 Program No. bit-1 Program No. bit-2 Program No. bit-3 Program No. bit-4 LED-1-1 ON LED-1-2 ON LED-1-3 ON LED-1-4 ON LED-1-5 ON LED-1-6 ON Reserved for input-1 Reserved for input-2 External emergency stop-1 External emergency stop-2 Common Input LED lighting-2 LED-2-1 ON LED-2-2 ON LED-2-3 ON LED-2-4 ON LED-2-5 ON LED-2-6 ON Description Selection of ON※1 enables external signal control (remote control). Selection of ON※1 makes the LED head-1 lit according to the conditions of the selected program. With one-shot ON※2 signal, program No. is changed. Specify the program No. for LED lighting. Using a string of 5 bits in total (32 possible values) from 0 to 4 bit, set the program No. Set the contents of the program in the touch screen. Selection of ON※1 makes the block 1 of the LED head-1 lit. Selection of ON※1 makes the block 2 of the LED head-1 lit. Selection of ON※1 makes the block 3 of the LED head-1 lit. Selection of ON※1 makes the block 4 of the LED head-1 lit. Selection of ON※1 makes the block 5 of the LED head-1 lit. Selection of ON※1 makes the block 6 of the LED head-1 lit. Reserved Reserved In the case of OPEN, the equipment comes to an immediate stop. (A dry contact must be used for this signal, being independent from the ones for other signals.) Common for Nos. 1 to 16 and Nos. 20 to 26 signals (for input) Selection of ON makes the LED head-2 lit according to the conditions of the selected program. Selection of ON※1 makes the block 1 of the LED head-2 lit. Selection of ON※1 makes the block 2 of the LED head-2 lit. Selection of ON※1 makes the block 3 of the LED head-2 lit. Selection of ON※1 makes the block 4 of the LED head-2 lit. Selection of ON※1 makes the block 5 of the LED head-2 lit. Selection of ON※1 makes the block 6 of the LED head-2 lit. ※1 Note: Depending on the connected LED head configuration, some pins may be disabled. 7 Specifications Model name ANUD4S10 ANUD4S20 ANUD4S30 ANUD4S40 ANUD4S50 ANUD4S60 Number of blocks 1 2 3 4 5 6 Input power supply voltage 200 to 240V ~ Input power supply frequency 50 to 60Hz Maximum input current 1A 2A 3A 4A 5A 6A Maximum power consumption 150W 250W 350W 450W 550W 650W AC inlet Terminal block (screw diameter of terminal block: ø4)※1 Number of radiation program patterns 32 patterns※2 Display/Setting/Operation Display/setting/operation from touch screen Method Parallel I/O (D-Sub37※3) LED lighting/Program selection/LED block individual lighting/ External External input Local or remote selection/External emergency stop control Equipment power ON/LED radiation ready/During radiation/ External output Alert/Error/Main unit emergency stop Dimming control※2 LED temperature feedback Configuration Cooling method Operating ambient temperature Operating ambient humidity Storage ambient temperature Storage ambient humidity Control unit Dimensions※4 Power unit Control unit Weight※5 Power unit-1 Power unit-2※6 Outer surface finish Control unit Included items Power unit 50 to 100% (in increments of 1%) Capability of keeping UV output constant by detecting LED head temperature. Separation of control part equipped with PLC and power supply for LED lighting Control unit: air cooling without fan, Power unit: forced cooling by fan 0 to +35ºC 30 to 85%RH (Free from condensation and freezing) -10 to +60ºC 30 to 85%RH (Free from dew condensation and freezing) W×H×D=280mm×222.2mm×560mm W×H×D=280mm×301mm×326mm Approx. 15kg Approx. 10kg Approx. 12kg Approx. 14kg Approx. 14kg Approx. 14kg Approx. 14kg Approx. 10kg Approx. 12kg Approx. 14kg Mat black painting Power keys, D-Sub37 connector Signal cable, AC connection cable, LED head connection cable ※1 Customers must prepare the power supply cable (AC supply cable) of the diameter appropriate for the maximum input current. ※2 Setting from touch screen ※3 Customers must prepare the cables connected to the D-Sub37 connector. ※4 Excluding the protruding parts of connectors and cables ※5 Excluding connectors and cables ※6 For the LED head consisting of 4 to 6 blocks, two power units are required. 8A3 M76 7000 1 Overseas Sales Division (Head Office) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 About our sale network, please visit our website. PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2015
© Copyright 2024