Product Guide - Numeris Locks

Product Guide
Keypad Camlocks
Code Managed
IMPORTANT:
Do not operate and turn the handle to the unlocked position without first installing the lock or
determining whether the lock is for a left or right handed configuration.
Lock Orientation - Views
Vertical
SOLA can be installed vertically or horizontally for left or right handed configuration.
Horizontal Left Handed
Locked Position
Unlocked Position
Horizontal Right Handed
Locked Position
Locked Position
Unlocked Position
Cam & Cam Stop Position
Note: The position of the cam and cam stop varies depending on whether it is
vertically or horizontally installed for a left or right handed configuration.
Vertical
Back-View
Cam throw: right
Locked Position
Horizontal Left Handed
Back-View
Cam throw: top
Unlocked Position
Cam throw: left
Locked Position
Unlocked Position
Locked Position
Cam throw: top
Unlocked Position
Cam throw: bottom
Unlocked Position
Locked Position
Horizontal Right Handed
Back-View
Locked Position
Unlocked Position
Cam throw: bottom
Unlocked Position
Locked Position
Unlocked Position
Phone: 707 766 6000
www.digilock.com | [email protected]
Product Guide
Keypad Camlocks
Code Managed
IMPORTANT:
Do not operate and turn the handle to the unlocked position without first installing the lock or
determining whether the lock is for a left or right handed configuration.
Hardware & Mounting
Door thickness: 0.1–5mm (.01”-.197”)
Use upper nut hardware
Door thickness: 6-10mm (.236”-.394”)
Use upper screw hardware
Sola Lock
Lock Base Seal
Lock Base Seal
Flat Washer
Flat Washer
Nut
Lock Base Seal
Flat Washer
Nut
Star Washer
Star Washer
Philips Screw
(M5 Pan Head)
Philips Screw
(M5 Pan Head)
Cam Stop*
11-14mm Door
14-18mm Door
18-22mm Door
Cam Stop*
Cam Stop*
*Refer to section on Cam
and Cam Stop Position
*Refer to section on Cam
and Cam Stop Position
*Refer to section on Cam
and Cam Stop Position
Cam
Cam
Cam
Flat Washer
Nut
Flat Washer
Philips Screw (M5 Pan Head)
Use upper screw hardware
Sola Lock
Sola Lock
Star Washer
Door thickness: 11-22mm (.433”-.866”)
Flat Washer
Star Washer
Nut
Flat Washer
Philips Screw (M5 Pan Head)
Flat Washer
Star Washer
Nut
Flat Washer
Philips Screw (M5 Pan Head)
Product Guide
Keypad Camlocks
Code Managed
Programming Instructions
INSTALL THE LOCK OR DETERMINE CONFIGURATION PRIOR TO
PROGRAMMING AND OPERATING.
Default Settings
Functionality = Shared Use
Owner Code (6-digit code) = 1 2 3 4 5 6
Manager Code (5-digit code) = 1 2 3 4 5
Initial Setup
New locks operate with the default Owner and Manager Codes. A new Owner and Manager Code must be programmed to prevent the
default codes from operating the lock.
Program a New Owner Code
The owner code can only be programmed using the current owner code.
a. Press = ` [current Owner Code] `. A two-tone beep will be heard and the LED will start to flash.
b. Press = [new Owner Code] `. A two-tone beep will be heard.
c. To confirm, press = [the same new Owner Code] `. Two sets of two-tone beeps will be heard and the LED will turn off.
Program a New Manager Code
To Program the Manager Code using the Owner Code:
a. Press = ` [Owner Code] `. A two-tone beep will be heard and the LED will start to flash.
b. Press = [new Manager Code] `. A two-tone beep will be heard.
c. To confirm, press = [the same new Manager Code] `. Two sets of two-tone beeps will be heard and the LED will turn off.
To Program the Manager Code using the current Manager Code:
a. Press = ` [current Manager Code] `. A two-tone beep will be heard and the LED will start to flash.
b. Press = [new Manager Code] `. A two-tone beep will be heard.
c. To confirm, press = [the same new Manager Code] `. Two sets of two-tone beeps will be heard and the LED will turn off.
Set Lock Functionality
Each lock can be set for either shared or assigned use functionality. In shared use functionality, the user enters a self-selected 4-digit
code to lock and later unlock. Once unlocked, the lock is available to be used by a different user. In assigned use functionality, the
lock is programmed with an assigned 4-7 digit code. The user enters the assigned 4-7 digit code to unlock and turns the handle to
relock. Press = to check functionality. If in shared use, LED is RED. If in assigned use, LED is GREEN.
Set lock for shared use functionality (default):
a. Press = ` [Owner Code] `. A two-tone beep will be heard and the LED will start to flash.
b. Press = 56 `. Two sets of two-tone beeps will be heard and a RED LED will flash twice.
c. Make sure the lock is unlocked and available for use. Use the Owner or Manager Code to unlock.
Set lock for assigned use functionality:
a.
b.
c.
d.
Press = ` [Owner Code] `. A two-tone beep will be heard and the LED will start to flash.
Press = 65 `. Two sets of two-tone beeps will be heard and a GREEN LED will flash twice.
Assign a User Code to the lock. Follow Assign a New User Code instructions.
Make sure the lock is in the locked position. Use the Owner or Manager Code to lock.
Assign a New User Code (for assigned use functionality only)
a. Press = ` [Manager Code] `. A two-tone beep will be heard and the green LED will start to flash.
b. Press = [new assigned 4-digit User Code] `. A two-tone beep will be heard.
c. Press = [the same new assigned 4-digit User Code] `. Two sets of two-tone beeps will be heard and the green LED will turn off.
Product Guide
Keypad Camlocks
Code Managed
Operating Instructions
Shared Use Functionality
Operate with a self-selected User Code:
Make sure the lock is unlocked and available for use.
▪▪ To lock: Close the door, press = [any 4-7 digit User Code] `, and then turn the handle to the locked position.
▪▪ To unlock: Press = [the same 4-digit code] `, turn the handle to the unlocked position, and then open the door.*
Operate with the Manager Code:
▪▪ To unlock: Press = [Manager Code] `, turn the handle to the unlocked position, and then open the door.*
▪▪ To relock: Close the door, press = [Manager Code] `, and then turn the handle to the locked position.**
Operate with the Owner Code:
▪▪ To unlock: Press = [Owner Code] `, turn the handle to the unlocked position, and then open the door.*
▪▪ To lock: Close the door, press = [Owner Code] `, and then turn the handle to the locked position.**
Assigned Use Functionality
Operate with an Assigned User Code:
▪▪ To unlock: Press = [assigned 4-7 digit user code] `, turn the handle to the unlocked position, and then open the door.*
▪▪ To relock: Close the door, then turn the handle to the locked position.
Operate with the Manager Code:
▪▪ To unlock: Press = [Manager code] `, turn the handle to the unlocked position, and then open the door.*
▪▪ To relock: Close the door, then turn the handle to the locked position.
Operate with the Owner Code:
▪▪ To unlock: Press = [Owner code] `, turn the handle to the unlocked position, and then open the door.*
▪▪ To relock: Close the door, then turn the handle to the locked position.
* After three consecutive incorrect entries to unlock, the lock will go into “Sleep Mode” for one minute and for an additional
minute for each subsequent incorrect entry. The keypad is disabled while in “Sleep Mode”.
**If a Manager or Owner Code is used to unlock and relock, the previous user credential (code or key) will continue to operate the lock.
Battery Replacement
1) Remove battery cover.
032515
PG-NMSK-SDC-DEN
2) Pull battery carrier out.
3) Replace with 2 AAA batteries.
4) Replace battery carrier along
with cover and secure.
Product Guide
Keypad Camlocks
Key Managed
IMPORTANT:
Do not operate and turn the handle to the unlocked position without first installing the lock or
determining whether the lock is for a left or right handed configuration.
Lock Orientation - Views
Vertical
SOLA can be installed vertically or horizontally for left or right handed configuration.
Horizontal Left Handed
Locked Position
Unlocked Position
Horizontal Right Handed
Locked Position
Locked Position
Unlocked Position
Cam & Cam Stop Position
Note: The position of the cam and cam stop varies depending on whether it is
vertically or horizontally installed for a left or right handed configuration.
Vertical
Back-View
Cam throw: right
Locked Position
Horizontal Left Handed
Back-View
Cam throw: top
Unlocked Position
Cam throw: left
Locked Position
Unlocked Position
Locked Position
Cam throw: top
Unlocked Position
Cam throw: bottom
Unlocked Position
Locked Position
Horizontal Right Handed
Back-View
Locked Position
Unlocked Position
Cam throw: bottom
Unlocked Position
Locked Position
Unlocked Position
Phone: 707 766 6000
www.digilock.com | [email protected]
Product Guide
Keypad Camlocks
Key Managed
IMPORTANT:
Do not operate and turn the handle to the unlocked position without first installing the lock or
determining whether the lock is for a left or right handed configuration.
Hardware & Mounting
Door thickness: 0.1–5mm (.01”-.197”)
Use upper nut hardware
Door thickness: 6-10mm (.236”-.394”)
Use upper screw hardware
Sola Lock
Lock Base Seal
Lock Base Seal
Flat Washer
Flat Washer
Nut
Lock Base Seal
Flat Washer
Nut
Star Washer
Star Washer
Philips Screw
(M5 Pan Head)
Philips Screw
(M5 Pan Head)
Cam Stop*
11-14mm Door
14-18mm Door
18-22mm Door
Cam Stop*
Cam Stop*
*Refer to section on Cam
and Cam Stop Position
*Refer to section on Cam
and Cam Stop Position
*Refer to section on Cam
and Cam Stop Position
Cam
Cam
Cam
Flat Washer
Nut
Flat Washer
Philips Screw (M5 Pan Head)
Use upper screw hardware
Sola Lock
Sola Lock
Star Washer
Door thickness: 11-22mm (.433”-.866”)
Flat Washer
Star Washer
Nut
Flat Washer
Philips Screw (M5 Pan Head)
Flat Washer
Star Washer
Nut
Flat Washer
Philips Screw (M5 Pan Head)
Phone: 707 766 6000
www.digilock.com | [email protected]
Product Guide
Keypad Camlocks
Key Managed
Keys
User Key
Manager Key*
Programming Key**
●
●
●
Overrides user access
●
●
Allows access for management inspection
●
●
Provides external power
●
●
Assigns user credential
●
Operates the lock
●
Sets lock functionality
*Up to 6 Manager Keys may be registered to a lock.
**1 Programming Key allowed per lock group.
Key Insertion
Key logo facing up
Key logo facing
to the right
Key logo facing
to the left
Horizontal Left-Hand
Vertical
Horizontal Right-Hand
For Lost or Stolen Keys
For a lost or stolen Programming Key:
A replacement Programming Key must be purchased and registered to the lock(s) to prevent the lost/stolen Programming Key from
accessing/programming a lock. Purchase a replacement Programming Key from an authorized dealer.
For a lost or stolen Manager Key(s):
All registered Manager Keys must be erased and only the remaining Manager Keys must be registered to the lock(s) to prevent the lost/
stolen Manager Key from accessing a lock. Purchase additional Manager Key(s) from an authorized dealer.
a. Collect all remaining Manager Key(s).
b. Press = ` 55 ` . The LED will turn on.
c. Touch the Programming Key to the key slot until a two-tone beep is heard.
d. Touch the Programming Key to the key slot again until three sets of two-tone beeps are heard and the LED turns off. All previously registered Manager Key(s) have been erased from the lock.
e. Follow Register/Add Manager Key(s) instructions to register the remaining Manager Key(s).
Battery Replacement
1) Remove battery cover.
2) Pull battery carrier out.
3) Replace with 2 AAA batteries.
4) Replace battery carrier along
with cover and secure.
Phone: 707 766 6000
www.digilock.com | [email protected]
Product Guide
Keypad Camlocks
Key Managed
Programming Instructions
INSTALL THE LOCK OR DETERMINE CONFIGURATION PRIOR TO
PROGRAMMING AND OPERATING.
Default Settings
Functionality = Shared Use
Initial Setup
New locks operate with = `. Locks must be setup to allow full operation.
a.
b.
c.
d.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on.
Touch each Manager Key to the key slot. A two-tone beep will be heard for each Manager Key that is successfully registered.
Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
Repeat above steps for each lock or follow Express Register instructions to setup all locks.
Express Register User Credential(s) and Manager Key(s)
User access credential(s) along with Manager Key(s) can be quickly registered to multiple locks. The Programming Key copies the
registered user access credential(s) and the registered Manager Key(s) from one lock to multiple locks.
a. Go to the lock assigned with the user access credential(s) and registered Manager Key(s).
b. Press = ` 66 `. The LED will turn on.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
d. At each lock to be registered, touch the Programming Key to the key slot until two sets of two-tone beeps are heard and the LED flashes once to indicate successful registration.
e. End express registration.* Go to any registered lock and press = ` then touch the Programming Key to the key slot to operate the lock.
* The Programming Key will continue to function in express registration mode until it is used to operate a lock.
Register/Add Manager Key(s)
Manager Key(s) can be registered to a lock after Initial Setup has been completed.
a. Go to the lock requiring Manager Key(s).
b. Press = ` 55 `. The LED will turn on.
c. Touch the Programming Key to the key slot until a two-tone beep is heard.
d. Touch each Manager Key to the key slot. A two-tone beep will be heard for each Manager Key that is successfully registered.
e. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off.
f. Repeat above steps for each lock or follow Express Register instructions to register the same Manager Key(s) to multiple locks.
Set Lock Functionality
Each lock can be set for either shared or assigned use functionality. In shared use functionality, the user enters a self-selected 4-digit
code or touches any User Key to lock and later unlock. Once unlocked, the lock is available to be used by a different user. In assigned
use functionality, the lock is programmed with an assigned user credential (4-7 digit code or User Key). The user enters the assigned
user credential to unlock and turns the handle to relock. Press = to check functionality. If in shared use, LED is RED. If in assigned use,
LED is GREEN.
Set lock for shared use functionality (default):
a. Press = ` 56 `. The LED will turn on.
b. Touch the Programming Key to the key slot until a two-tone beep is heard and the RED LED flashes once.
c. Make sure the lock is unlocked and available for use. Use a registered Manager Key or the Programming Key to unlock.
Set lock for assigned use functionality:
a.
b.
c.
d.
Press = ` 65 `. The LED will turn on.
Touch the Programming Key to the key slot until a two-tone beep is heard and the GREEN LED flashes once.
Assign a user credential (code or key) to the lock. Follow Assign a User Credentials instructions.
Make sure lock is in the locked position. Use a registered Manager Key or the Programming Key to lock.
Phone: 707 766 6000
www.digilock.com | [email protected]
Product Guide
Keypad Camlocks
Key Managed
Assign User Credential(s) (for assigned use functionality only)
Make sure that the lock is set for assigned use functionality. Up to 20 user access credentials can be assigned to operate the lock.
Assign a User Code (default user code = 1234567):
a. Press = ` then touch a registered Manager Key to the key slot until the green LED turns on.
b. Press = [new assigned 4-7 digit User Code] `. A two-tone beep will be heard.
c. Press = [the same new assigned 4-7 digit User Code] `. Two sets of two-tone beeps will be heard and the LED will turn off.
Assign a User Key:
a. Press = ` then touch a registered Manager Key to the key slot until the green LED turns on.
b. Touch any User Key to be assigned to the key slot until a two-tone beep is heard and the LED turns off.
Operating Instructions
Shared Use Functionality
Operate with a self-selected User Code:
Make sure the lock is unlocked and available for use.
▪▪ To lock: Close the door, Press = [any 4-7 digit User Code] `, and then turn the handle to the locked position.
▪▪ To unlock: Press = [the same 4-7 digit User Code] `, turn the handle to the unlocked position, and then open the door.*
Operate with any User Key:
▪▪ To lock: Close the door, touch any User Key to the key slot, and then turn the handle to the locked position.
▪▪ To unlock: Touch any User Key to the key slot, turn the handle to the unlocked position, and then open the door.
Operate with a registered Manager Key:
▪▪ To unlock: Touch any registered Manager Key to the key slot, turn the handle to the unlocked position, and then open the door.
▪▪ To relock: Close the door, touch any registered Manager Key to the key slot, and then turn the handle to the locked position.**
Operate with the Programming Key:
▪▪ To unlock: Press = `, touch the Programming Key to the key slot, turn the handle to the unlocked position, and then open the door.
▪▪ To relock: Close the door, press = `, touch the Programming Key to the key slot, and then turn the handle to the locked position.**
Assigned Use Functionality
Operate with an assigned User Code:
▪▪ To unlock: Press = [assigned 4-7 digit User Code] `, turn the handle to the unlocked position, and then open the door.*
▪▪ To relock: Close the door and then turn the handle to the locked position.
Operate with an assigned User Key:
▪▪ To unlock: Touch the assigned User Key to the key slot, turn the handle to the unlocked position, and then openthe door.
▪▪ To relock: Close the door and then turn the handle to the locked position.
Operate with a registered Manager Key:
▪▪ To unlock: Touch a registered Manager Key to the key slot, turn the handle to the unlocked position, and then open the door.
▪▪ To relock: Close the door and then turn the handle to the locked position.
Operate with the Programming Key:
▪▪ To unlock: Press = `, touch the Programming Key to the key slot, turn the handle to the unlocked position, and then open the door.
▪▪ To relock: Close the door and then turn the handle to the locked position.
* After three consecutive incorrect entries to unlock, the lock will go into “Sleep Mode” for one minute and for an additional minute for each subsequent
incorrect entry. The keypad is disabled while in “Sleep Mode”. For immediate access, use the Manager Key or Programming Key.
**If a Manager Key or Programming Key is used to unlock and relock, the previous user credential (code or key) will continue to operate the lock.
032515
PG-NMSK-SDK-DEN
Phone: 707 766 6000
www.digilock.com | [email protected]