FAAC XSH V1

X
S
H
M
u
l
t
i
s
e
n
s
o
r
c
a
r
d
C
a
r
d
f
o
r
t
h
e
c
o
n
n
e
c
t
i
o
n
o
f
4
s
e
n
s
o
r
s
NOT USED
SENSOR # 4
SENSOR # 3
SENSOR # 2
STD TEST
100Hz
MONIT. TYPE
SENSOR # 1
10 MIN
20 SEC
MONIT. TIME
Input 1: Green LED
IN1
ASYNC
SYNC
MONIT. MODE
3 4 5 6 7 8 9 10
4SAFE = XPB
ACTIV8 = XDT1, XV1, XBFA ON
IN2
ON
OFF
RELAY DEBOUNCE
LOGIC OUT 1
SENSOR TYPE
1+2
PUSH BUTTON: CONFIRM DIP SWITCH SETTING
PASSIVE
PASSIVE
ACTIVE
LOGIC OUT 2
4SAFE
ACTIV8
ACTIVE
4
3
2
1
OUT1
Output 2: Red LED
# SENSORS
CONNECTED
Output 1: Green LED
OUT2
CONTROL UNIT
DESCRIPTION
Input 2: Red LED
ON
Door controller
connector
Sensor connectors
1 2 3 4 5 6 7 8 9 10
Yellow LED
DIP-switches
Confirmation push button
LED SIGNAL
GREEN
ON
Output 1
Input 1
RED
ON
Output 2
Input 2
LED switches ON
during detection
Active
mode
LED switches OFF
during detection
Passive
mode
YELLOW
flashing
Awaiting confirmation
DIP-switch setting
TECHNICAL SPECIFICATIONS
Max. load current:
2A
Supply voltage:
12 V DC - 24 V DC +10% (min. 16 V DC @ max. load current)
Output to door controller:
2 galvanically isolated outputs (OPTOFET; UMAX= 42 V DC; IMAX= 100 mA)
maximum output power dissipation: 200 mW
off-state leakage current: 10 µA
on-state maximum resistance: 20 Ohms
Monitoring input from door controller:
1 galvanically isolated input (Optocoupler; max 30 V DC (6 mA));
voltage threshold: logic high: >10 V DC (2 mA); logic low: <1 V DC
Input from each sensor:
2 non-isolated inputs
Monitoring output to each sensor:
1 non-isolated output (UOUT= USUPPLY; IMAX= 50 mA)
Monitoring response time:
from 200µs to 50ms (depending on sensors & XSH setting)
LEDs:
red & green for status display of each connected sensor
red & green for XSH output status display
orange for DIP-switch status change display
Norm conformity:
EMC 2004/108/EC
EN ISO 13849-1:2006 Performance Level "c”, CAT 2
EN 62061:2005 SIL 2
Temperature range:
from -25° to +60° (for indoor use only)
Dimensions:
70 mm (L) x 55 mm (H) x 25 mm (D)
Housing material:
ABS (translucent blue)
Length of sensor cables:
2.70 m
Length of power cable:
2.60 m
Specifications are subject to changes without prior notice.
1/2
WIRING
DOOR CONTROLLER
XSH
1.
2.
GREEN
ON
BROWN
1 2 3 4 5 6 7 8 9 10
YELLOW
24V DC
GND
SENSOR #4
SENSOR #3
SENSOR #2
SENSOR #1
CABLE TO
DOOR CONTROLLER
IN 1
OUTPUT 1
WHITE
IN 1
GREY
OUTPUT 2
IN 2
PINK
IN 2
RED
+
BLUE
1. Connect the sensors (from 1 to 4)
to the sensor connectors starting from the left
using the cables that have connectors on both ends.
-
Attention! Never use the 4SAFE power cable to connect
the XSH to the door controller.
2. Connect the cable with only one connector from the XSH to the door controller (see wiring diagram).
DIP-SWITCH SETTINGS
1
2
3
4
Number of sensors
connected to the XSH
Type of sensor
connected to the XSH
Logic Output 1
ON
ON
Logic Output 2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 sensor
2 sensors
3 sensors
4 sensors
ON
7
Relay debounce
avoids the bouncing
of the relay contact during
a monitoring request
42.8263 - V1 / 07.14
8
9
Monitoring cycle time
in asynchronous mode
Monitoring type
ON
ON Passive
ON
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
10
Only one type of sensor can be connected simultaneously.
Do not mix sensor types.
1 2 3 4 5 6 7 8 9 10
Monitoring mode
The monitoring has to be
active on
all connected sensors!
ON 4SAFE=XPB
OFF ACTIV8 =
XDT1, XV1, XBFA ON
1 2 3 4 5 6 7 8 9 10
6
ON
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
5
ON
OFF Active
ON Passive
Check the output logic on the connected sensors.
The output logic has to be the same on the XSH and on all
connected sensors (see LED-signal).
OFF Active
Check the output logic on the connected sensors.
The output logic has to be the same on the XSH and on all
connected sensors (see LED-signal).
ON ON
Recommended when the monitoring input is connected to a
relay output on the door controller.
OFF OFF
Set to OFF for a faster response time.
ON Asynchronous
OFF Synchronous
The XSH sends a monitoring request to all connected sensors every x
seconds (according to DIP 8 setting), independent of the door controller.
When the door controller sends a monitoring request to the XSH, it
answers immediately giving the result of the last monitoring cycle.
The XSH sends a monitoring request to all connected sensors only when
the door controller sends a monitoring request to the XSH. The response
time on monitoring request is dependent on response time of the
connected sensors.
ON 10 min
The XSH sends a monitoring request to all connected
sensors every 10 minutes (only in asynchronous mode).
OFF 20 sec
The XSH sends a monitoring request to all connected
sensors every 20 seconds (only in asynchronous mode).
Standard voltage
ON monitoring
OFF Signal output
100 Hz
Most frequently used type of monitoring using test input.
Only if your door controller is compatible with
this type of monitoring.
Not used
YELLOW
OFF
After changing one or more DIP-switch settings, the yellow
LED flashes. Confirm the new setting(s) by pushing the push
button until the LED switches off. The setting is confirmed.
FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com
Manufactured by BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - B-4031 Angleur - T +32 4 361 65 65 - F +32 4 361 28 58 - [email protected] - www.bea.be