www.droab.se TMLS magnetic linear encoders Magnetic linear encoders TMLS Supplier: Bength Inge Paulsson Älvgatan 6 252 30 Helsingborg Tel.: 0705-210 331 www.droab.se e-mail: [email protected] Page 1 www.droab.se TMLS magnetic linear encoders Technical specification Encoder model TMLS-25B Encoder model TMLS-05A Resolution: 0.025 mm Output signal: TTL Supply voltage: 5V Max. meas. speed: 60 m / min. Working temperature: 0 – 85 °C Protection: IP67 Resolution: 0.005 mm Output signal: TTL Supply voltage: 5V Max. meas. speed: 60 m / min. Working temperature: 0 – 85 °C Protection: IP67 Magnetic linear encoder connector description Pin 1 2 3 4 Signal 0V (shielding is connected to the connector body) 5 - 6 A 7 +5V 8 B 9 Z 7 +5V 8 B 9 Z Magnetic linear encoder connector description for the RS-422 Pin 1 2 3 4 Signal -Z 0V -B (shielding is connected to the connector body) 5 -A TMLS-05A-02 magnetic linear encoder 6 A TMLS-25B-02 magnetic linear encoder Page 2 www.droab.se TMLS magnetic linear encoders MT magnetic tape Steel cover tape Width: 10 mm Thickness: 1.3 mm Max. length: 50 m Magnetic tape Steel base tape Aluminium protection profiles: AP-01 – aluminium protection profile intended particularly for the TMLS-05A-05 encoders. - The profile consists of a base profile and a cover profile. Both the profiles are joined together by the screws M3x5 which are delivered with the profile. The base profile can be fastened by the screws M4 with a special flat screwhead – the screws are delivered with the profile. A groove for the magnetic tape is produced in the cover profile. This profile provides you with total protection of the magnetic tape against ambient impurities like dust, cooling liquids, metal chips etc. Holes for fastening the base profile by the screws M4 – delivered with the profile Cover profile Base profile Gap for the magnetic tape Screws M3 enabling to join the base profile and the cover profile - delivered with the profile Page 3 www.droab.se TMLS magnetic linear encoders AP-02 – aluminium protection profile intended particularly for the TMLS-05A-02, TMLS-01A-02, TMLS-25B-02 encoders. The „L“ cover can be fastened to the profile - The profile is produced by drawing to ensure homogenous dimensions along all the length. The profile is surface treated. The „T“ groove situated in the upper part of the profile enables you to fasten protection „L“ cover which protects the measuring components against coarse impurities. The profile can be fastened by the screws M4 with a special flat screwhead – the screws are delivered with the profile. The profile should be mounted onto the machine at first. Then put the magnetic tape into the groove over the fastening screws. After that insert a special stainless steel tape. It protects the magnetic tape against all the ambient influences (cooling liquids, metal chips, dust etc.). The stainless steel tape should be secured by sealing rubber inserted into the internal lateral grooves. The stainless steel tape and the sealing rubber are delivered with the profile. Before monting the „L“ cover, insert a flat nuts into the groove situated in the upper part of the profile. Then fasten the cover by the screws (all the components are delivered with the profile). Ending elements can be fastened to both the ends of the AP-02 profile and the „L“ cover. Page 4 www.droab.se TMLS magnetic linear encoders Mounting the encoder, magnetic tape, aluminium profiles Positioning the encoder: The TMLS encoder heads are fully water-tight and dust-tight. If you intend to stick the MT magnetic tape on the machine, it should be perfectly protected against cooling liquids (the cooling liquid can affect the adhesive layer and unstick the tape). The AP aluminium profiles protect the tape against cooling liquids and unwanted damaging the tape. However it is necessary to ensure protection against coarse impurities – when using the AP-01 profile. Total protection can be also assured by the AP-02 profile with the „L“ cover. Maximum air gap between the magnetic tape and the encoder head is 1 mm for the TMLS-25B02, TMLS-05A-02 and TMLS-01A-02 encoders and 2.5 mm for the TMLS-05A-05 encoders (to ensure maximum accuracy it is recommended to adjust the air gap as small as possible. Air gap between the aluminium profile and the encoder head should be in the range of 0.2 up to 1mm). You should ensure the encoder head does not touch the aluminium profile. Direct mounting the MT magnetic tape If the aluminium profile not used, the MT magnetic tape should be glued on a carefully cleaned, grease free surface. Then cover the magnetic tape with the stainless steel tape. You can mechanically ensure both ends of the tape against unglue (eg. by screws). Be carefull not to obstruct free movement of the head. Mounting the magnetic tape protected by the AP aluminium profiles Mounting the AP-01 profile a. Choose a correct place for mounting. b. Mark and drill holes with threads M4 on the surface according to the length of the profile. c. Mount the base profile onto the surface, do not tighten the screws. Use a scale indicator to adjust and check parallelity between the profile and movement of the machine. d. Tighten the fastening screws. e. Put the cover profile onto the base profile and fasten it by screws. Do not tighten the screws. f. Insert the magnetic tape into the groove (the dark magnetic layer must point to the encoder head) and tighten the screws of the cover profile. g. It is recommended to spread a thin layer of silicone under both ends of the magnetic tape. h. Mount the encoder head to ensure constant air gap between the upper surface of the aluminium profile and the bottom surface of the encoder head. Max. nonparallelity between the head and the profile is ±0.15mm, max. change of the air gap is ±0.1mm. i. When mounting the encoder heads, we recommend to use the mounting holders of our production. Page 5 www.droab.se TMLS magnetic linear encoders AP-01 aluminium profile Cover profile Mag.tape Silicone Base profile Mounting the AP-02 profile a. Choose a correct place for mounting. b. Mark and drill holes with threads M4 on the surface according to the length of the profile c. Mount the profile onto the surface, do not tighten the screws. Use a scale indicator to adjust and check parallelity between the profile and movement of the machine. d. Tighten the fastening screws. e. Insert the stainless steel tape into the groove. f. Insert the magnetic tape into the groove (the dark magnetic layer must point to the encoder head) under the stainless steel tape. Eventually, you can glue the magnetic tape into the groove. g. Insert the sealing rubbers into the internal lateral grooves – the sealing rubbers reliably fix the stainless steel tape and the magnetic tape. h. Mount the encoder head to ensure constant air gap between the upper surface of the stainless steel tape and the bottom surface of the encoder head. Max. nonparallelity between the head and the profile is ±0.15mm, max. change of the air gap is ±0.1mm. i. When mounting the encoder heads, we recommend to use the mounting holders of our production. Mounting the ”L” cover a. Insert nuts M3 into the T-groove of the profile. b. Put the ”L” cover onto the profile. c. Fasten the ”L” cover using the delivered screws M3 Page 6 www.droab.se TMLS magnetic linear encoders Mounting the reference point - The reference point is represented by a magnet delivered with the encoder head. Mount the magnet to generate a pulse when moving the encoder head along the magnet (distance between the encoder head and the magnet should be 1-2 mm; the marked side of the magnet must point to the encoder head). The magnet must be mounted on the marked side of the encoder head (see the photo). - Activate the function of the reference point in the digital readout. - Always move to the reference point from the same direction. Marked reference point on the head Encoder head Magnetic tape or aluminium profile Reference magnet Encoder head with marked reference point. Page 7
© Copyright 2024