Thank you for allowing Pro View to provide you with your home property inspection. Our goal was to provide you with a complete, accurate, and easy to understand report of the present condition of your future home. If you have any questions, or need help understanding this report, please do not hesitate to call us. It is our pleasure to serve you. We hope we have fulfilled your expectations as your home inspection provider. Thank you, once again, for choosing Pro View Property Inspection. Craig Rhyne Inspector Inspector : Craig Rhyne Phone : (914)837-6115 TABLE OF CONTENTS Work Agreement Invoice Cover Page Key to Understanding Report Grounds Exterior Foundation Roof Plumbing Heating Cooling Electrical Interior Interior - Continued Garage Kitchen Bathrooms Pool / Spa REPORT SUMMARY Photo Pages Pro View Property Inspection 41224 N. Congressional Dr. Anthem, Az Phone (623)551-0369 Fax (623)551-0603 THIS IS INTENDED TO BE A LEGALLY BINDING CONTRACT... PLEASE READ CAREFULLY. Report #: JONES 05112015 Client: Nancy Jones Address: 40451 Congressional Dr. City/State/Zip: Anthem, Az 85086 Subject Property 40451 Congressional Dr. Anthem, Az 85086 I/We (Client) hereby request a limited visual inspection of the structure at the above address to be conducted by Pro View Property Inspection, (Inspector), for my/our sole use and benefit. I/We warrant that I/We will read the following agreement carefully. I/We understand that I/We are bound by all the terms of this contract. I further warrant that I will read the entire inspection report when I receive it and promptly call the inspector with any questions I may have. SCOPE OF INSPECTION The scope of the inspection and report is a limited visual inspection of the general systems and components of the home to identify any system or component listed in the report which may be in need of immediate major repair. The inspection will be performed in accordance with the Standards of Professional Practice adopted by the Arizona State Board of Technical Registration, a copy of which is available upon request. OUTSIDE SCOPE OF INSPECTION Any area which is not exposed to view, is concealed, or is inaccessible because of soil, walls, floors, carpets, ceilings, furnishings, or any other thing is not included in this inspection. The inspection and report are for conditions observed at the time of the inspection, any defects or failures to general systems and components after the inspection are outside the scope of this inspection. The inspection does not include any destructive testing or dismantling. Client agrees to assume all the risk for all conditions which are concealed from view at the time of the inspection. This is not a home warranty, guarantee, insurance policy or substitute for real estate transfer disclosures which may be required by law. Whether or not they are concealed, the following ARE OUTSIDE THE SCOPE OF THIS INSPECTION Our inspection will not include cosmetic items or finish blemishes. Specific components noted as being excluded on the individual systems inspection forms Private water or private sewage systems Saunas, steam baths, or fixtures and equipment Pool or spas equipment and bodies, underground piping Radio-controlled devices, remote pool lighting, automatic gates, elevators, lifts, dumbwaiters and thermostatic or time clock controls Water softener / purifier systems or solar heating systems, irrigation/sprinkler system Furnace heat exchangers, evaporative coolers, freestanding appliances, security alarms, intercom systems or personal property Adequacy or efficiency of any system or component Prediction of life expectancy of any item Building code or zoning ordinance violations, building permit filing status Building value appraisal or cost estimates Building fire extinguishing systems Geological stability or soils condition Structural stability or engineering analysis Termites, pests or other wood destroying organisms Mold, asbestos, radon, lead, Chinese drywall, formaldehyde, water or air quality, electromagnetic radiation or any environmental hazards Conditions behind or inside of walls or ceilings, infrared inspections Condition of roofing paper under roof tiles, shingles or other weather element protective material Condition of garage storage cabinets, detached buildings or structures (Some of the above items may be included in this inspection as a courtesy. BOLD items may be reported for an additional fee – if samples have been gathered for testing, results apply to the location of samples taken only, entire home was not tested). Your inspector is a home inspection generalist and is not acting as a licensed engineer or expert in any craft or trade. Page 1 of 2 Pro View Property Inspection Client: Nancy Jones Contract continued Report #: Jones 05112015 THIS IS INTENDED TO BE A LEGALLY BINDING CONTRACT... PLEASE READ CAREFULLY. ARBITRATION: Any dispute, controversy, interpretation or claim including claims for , but not limited to, breach of contract, any form of negligence, fraud or misrepresentation or any other theory of liability arising out of, from or related to, this contract or arising out of, from or related to the inspection or inspection report shall be submitted to final and binding arbitration "under the rules and procedures of the Expedited Arbitration of Home Inspection Disputes of Construction Arbitration Services, Inc." The decision of the Arbitrator appointed thereunder shall be final and binding and judgment on the Award may be entered in any Court of competent jurisdiction. USE BY OTHERS: Client promises Inspector that Client has requested this inspection for Client's own use only and will not disclose any part of the inspection report to any other person with these exceptions ONLY: one copy may be provided to the current seller(s) of the property for their use as part of this transaction only, and one copy may be provided to the real estate agent representing Client and/or a bank or other lender for use in Client's transaction only. ATTORNEY'S FEES: The prevailing party in any dispute arising out of this agreement, the inspection, or report(s) shall be awarded all attorney's fees, arbitrator fees and other related costs. SEVER ABILITY: Client and Inspector agree that should a Court of Competent Jurisdiction determine and declare that any portion of this contract is void, void able or unenforceable, the remaining provisions and portions shall remain in full force and effect. DISPUTES: Client understands and agrees that any claim for failure to accurately report the visually discernible conditions at the Subject Property, as limited herein above, shall be made in writing and reported to the Inspector within ten business days of discovery. Client further agrees that, with the exception of emergency conditions, Client or Client's agents, employees or independent contractors, will make no alterations, modifications or repairs to the claimed discrepancy prior to a re-inspection by the Inspector. Client understands and agrees that any failure to notify the Inspector as stated above shall constitute a waiver of any and all claims for said failure to accurately report the condition in question. LIQUIDATED DAMAGES It is understood and agreed by and between the parties hereto that the INSPECTOR/INSPECTION COMPANY is not an insurer, that the payment for the subject inspection is based solely on the value of the service provided by the INSPECTOR/INSPECTION Company in the performance of the limited visual inspection and production of a written inspection report as described herein, that it is impracticable and extremely difficult to fix the actual damages, if any, which may result from a failure to perform such services and in case of failure to perform such services, and a resulting loss the INSPECTOR/INSPECTION COMPANY'S liability here under shall be limited and fixed in an amount equal to the inspection fee paid multiplied by two (2), or to the sum of five hundred dollars ($500.00), whichever sum shall be less, as liquidated damages, and not as a penalty, and this liability shall be exclusive. No legal action or proceeding of any kind, including those sounding in tort or contract, can be commenced against the Inspector/Inspection Company, or its officers, agents or employees more than one year after the date of the subject inspection. Time is expressly of the essence herein. The written report to be prepared by Inspector shall be considered the final and exclusive findings of the Inspector regarding the inspection of the property. Client shall not rely on any oral statements made by the Inspector prior to issuance of the written report .This agreement shall be binding upon and inure to the benefit of the parties hereto, their heirs, successors, assigns, agents, and representatives of any kind whatsoever. This agreement constitutes the entire integrated agreement between the parties hereto pertaining to the subject matter hereof, and may be modified only by a written agreement signed by all of the parties hereto. No oral agreements, understandings, or representations shall change, modify, or amend any part of this agreement. INSPECTOR : Craig Rhyne Inspector Phone (914)837-6115 SUB TOTAL: $475.00 PAYMENT: TOTAL DUE: $475.00 Page 2 of 2 © EZ Report Copyright Pro View Property Inspection 41224 N. Congressional Dr. Anthem, Az Phone (623)551-0369 Fax (623)551-0603 Invoice Nancy Jones 40451 Congressional Dr. Anthem, Az 85086 Subject Property: 40451 Congressional Dr. Anthem, Az 85086 Invoice Date: Inspection Date: May 11, 2015 Invoice #: Report #: JONES 05112015 Inspector : Craig Rhyne INSPECTION FEES DESCRIPTION AMOUNT Title Company Information Payment Processing Fee: Inspection Fee: $400.00 Reinspection Fee: Pool/Spa: Age Fee: $75.00 *Other Services: SUB TOTAL : $475.00 DISCOUNT : INVOICE TOTAL: $475.00 PAYMENT: TOTAL DUE : $475.00 *You may view your Order Confirmation email for a list of Other Services performed Please Remit to: Pro View Property Inspection 41224 North Congressional Dr. Anthem, AZ 85086 Phone (623)551-0369 Fax (623)551-0603 © EZ Report Copyright Pro View Property Inspection 41224 N. Congressional Dr. Anthem, Az Phone (623)551-0369 Fax (623)551-0603 Report ID# JONES 05112015 Schedule Date Monday, May 11, 2015 Nancy Jones 40451 Congressional Dr. Anthem, Az 85086 Subject Property 40451 Congressional Dr. Anthem, Az 85086 © EZ Report Copyright Pro View Property Inspection Page 3 REPORT # : JONES 05112015 KEY TO THE INSPECTION REPORT This Report lists the systems and components inspected by this company. Items not found in this report are considered beyond the scope of this inspection, and should not be considered inspected at this time. "N/A" - NOT APPLICABLE "A/S" - APPEAR SERVICEABLE" means that we did not observe conditions that would lead us to believe problems existed with this system or component. The item is capable of being used. Some serviceable items may, however, show wear and tear. Other conditions if applicable, will be noted in the body of the report. "R/I - RE-INSPECTED ITEM" Items that were re-inspected at subsequent inspection. Significantly deficient systems or components will be identified as: Not functional / unsafe / worn / near end of life span. When in the inspector's opinion, an item is "significantly deficient", the reason will be within the body of the report. Please read the entire report for all items . Notice: This report contains technical information that may not be readily understandable to the lay person. Therefore, a verbal consultation with the inspector is a mandatory part of this inspection report. If you choose not to consult with the inspector, this inspection company cannot be held liable for your understanding or misunderstanding of this report's contents. If you were not present during this inspection please call the office to arrange for your verbal consultation. KEY TO THE INSPECTION REPORT * Items that have an asterisk next to them. This item or component warrants additional attention, repair or monitoring. (1) (1) (2) Items that have a (1) next to them. The Bracketed Numbers are defined as follows: Recommended evaluation by a qualified licensed structural engineer. Recommend further evaluation and repairs as needed by a qualified licensed contractor or specialty tradesman dealing with that item or system. (3) (4) (5) Recommend further review for the presence of any wood destroying pests or organisms by qualified Pest Inspector. This item is a safety hazard - correction is needed Recommend upgrading for safety enhancement. If you do not understand how to read this report please contact our office. Present During The Inspection: Client Buyer's Agent Seller's Agent INSPECTOR : Craig Rhyne No one Phone (914)837-6115 Completion Time: 1:30 pm Start Time: 9:00 am Inspection Date: May/11/2015, Monday Seller The weather condition at the time of inspection was Approximate temperature during inspection Property Information: The subject property inspected was a (an): Gas was on for inspection: ----Water was on for inspection: ----Electric was on for inspection: ----- Single Family. # of units 1 Approximate year built: 2003 Recommend reinspection when gas is available Recommend reinspection when water is available Recommend reinspection when electric is available NOTICE: It is always wise to check with the building department for permit information, especially if additions or alterations are noted. IMPORTANT NOTICE TO THIRD PARTIES OR OTHER PURCHASERS: RECEIPT OF THIS REPORT BY ANY PURCHASERS OF THIS PROPERTY OTHER THAN THE PARTY(IES) IDENTIFIED ON THE CONTRACT PAGE #1 IS NOT AUTHORIZED BY THE INSPECTOR. THE INSPECTOR STRONGLY ADVISES AGAINST ANY RELIANCE ON THIS REPORT. WE RECOMMEND THAT YOU RETAIN A QUALIFIED PROFESSIONAL INSPECTOR TO PROVIDE YOU WITH YOUR OWN INSPECTION AND REPORT ON THIS PROPERTY. © EZ Report Copyright PRO VIEW PROPERTY INSPECTION Page 4 KEY: GROUNDS REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 1 Driveway Appears serviceable N/A R/I Defects* Type: (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Asphalt Common cracks Concrete Trip hazards* ----- Recommend further evaluation* See Report Summary for more information 2 Sidewalks Appears serviceable N/A R/I Defects* Type: Common cracks Concrete Brick Trip hazards* ----- Recommend further evaluation* See Photo Summary Page See Report Summary for more information 3 Retaining Walls N/A Appears serviceable Defects* R/I Concrete Location(s) ----- Common cracks No drainage openings* Stucco Block Recommend further evaluation* See Report Summary for more information 4 Patio(s) Appears serviceable N/A R/I Common cracks Defects* 5 Patio Cover Appears serviceable Brick Major cracks (2) BBQ Appears Serviceable Recommend further evaluation* See Photo Summary Page Concrete Location(s) Southwest Cool Deck finish Trip hazards* BBQ Maintenance needed* See Report Summary for more information N/A R/I Defects* Earth contact (3) Location(s): Southwest Type: Open Design Covered Roof (refer to Roof Page)* Wood frame/stucco Patio Column(s) ; Appear serviceabe Recommend further evaluation* See Photo Summary Page 6 Decks / Porch Appears serviceable See Report Summary for more information N/A R/I Location(s): A Type: WOOD B ----- Railings are serviceable Defects* C ----- Waterproof Coating N/A Recommend further evaluation* See Photo Summary Page See Report Summary for more information 7 Fences & Gates N/A Appears serviceable Defects* Recommend further evaluation* R/I Type: CMU Common cracks Self closing device is operational Wood Chain Link Gate(s) need adjustment Recommend installing pool fence for safety(5) See Photo Summary Page See Report Summary for more information PRO VIEW PROPERTY INSPECTION EXTERIOR Page 5 KEY: REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information R/I Location: A ----- N/A 8 Exterior Stairs (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Appears serviceable Defects* Recommend further evaluation* C --------- B --------- Type: ----Railings ----- Openings in rails too large (5) See Report Summary for more information N/A 9 Exterior Walls Appears serviceable R/I Defects* Structure: WOOD FRAME Wall Covering: Stucco Common cracks* Major cracks (2) Cracks / openings need repair* Recommend further evaluation* See Photo Summary Page See Report Summary for more information Notice: Wall insulation type and value is not verified* UFFI insulation or hazard are not identified* is not performed* 10 Trim / Fascia N/A R/I Type: WOOD Eaves, soffits, facia & trim appears serviceable Recommend further evaluation* Conditions inside the wall cannot be judged* META VINYL Not fully visible* Lead paint testing STUCCO Moisture stains at ----- Drip edge not installed* See Report Summary for more information 11 Chimney(s) Material: A Stucco Appears serviceable R/I Location: A Living Room B ----- N/A B ----Defects* D ----- C ----- Spark screen is Recommend further evaluation* C ----- D ----CHIMNEY PIPE METAL FLUE Raincap is ----- Recommend adding Chimney Cricket* present ----- See Photo Summary Page See Report Summary for more information Notice: The interior of the flue was not inspected at this time. We recommend that you retain a qualified chimney sweep to clean and evaluate the flue * 12 Sprinklers Appears serviceable N/A R/I Non operational* Control Box Location; Northwest side See Sprinkler page for the Full Sprinkler Inspection Defects* Recommend further evaluation* See Report Summary for more information Notice: Underground pipes cannot be judged for breaks or possible root intrusions. Association-maintained systems are not tested. Grove systems are not tested.* 13 Hose Faucets N/A R/I Faucets are Appear serviceable See Photo Summary Page See Report Summary for more information 14 Gutters & Downspouts Appears serviceable not anti-siphon type valve (5) Recommend further evaluation* Defects* N/A R/I Full Partial Recommend adding gutters* None Installed Route downspouts away from building* Recommend further evaluation* See Report Summary for more information Notice: Gutters and subsurface drains are not water tested for leakage or blockage.* foundation.* Regular maintenance of drainage systems is required to avoid water problems at the roof and PRO VIEW PROPERTY INSPECTION FOUNDATION Page 6 KEY: (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 15 Grading N/A R/I Level Site REPORT # : JONES 05112015 (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Steep (1) Not fully visible* Drainage of site/slope of soil at foundation appears serviceable Improper soil slope toward foundation* Soil / pavement is high at foundation* Overgrown landscaping* Plants touch plants too close to Trees planted close to structure * Signs of poor drainage / erosion* Recommend further evaluation* See Photo Summary Page Slope Minor Moderate See Report Summary for more information Notice: This inspection does not include geological conditions or site stability information. For information concerning these conditions, a geologist or soils engineer should be consulted. 16 Slab-on-grade Foundation type: Visible Crawlspace: 17 Crawlspace Poured Concrete Masonry Block Partially visible* Not visible at* ----Concrete Entered crawl space Door Cover : Steel Wood No access* OK Damaged* N/A 18 Basement Brick Masonry Block R/I Stone Piers Wood Recommend further evaluation* Brick Not Visible* Partial access* Viewed from access opening only* Crawlspace Basement ----Missing* Condition: Appears serviceable No cracks found Defects* Cracks appear common in size and type* Slab not visible due to Carpet and floor covering recommend further evaluation by removal of floor covering. See Photo Summary Page See Report Summary for more information Notice: All slabs experience some degree of cracking due to shrinkage in the drying process. In most instances floor coverings prevent recognition of cracks or settlement in all but the most severe cases. The inspector will, at additional cost, reinspect, provided the client removes floor covering and releases the inspector from damage caused by this process. Floor coverings are not removed during this inspection.* Floor Construction first level: Floor Construction second level: Floor Framing Size: 2x4 Appears serviceable N/A Crawlspace ventilation: Insulation: Fiberglass VAPOR RETARDER N/A Sump pump N/A Crawlspace : Defects* Joists N/A Concrete Post Tension Conventional wood framing Joists Joists Beams Post Columns Serviceable Vents are blocked Material is Installed Serviceable Woo Woo Cellulose Trusses Not visible Trusses Not visible Debris under house* Vermiculit Not installed* Not visible* Loose* Not functional* Pump not tested* are inadequate Foa are needed None Installed incorrectly* Sump pump needed* Recommend further evaluation* See Report Summary for more information BASEMENT STAIRS N/A ----Railings Recommend further evaluation* R/I Appears serviceable Stairs too steep (2)(4)(5) Ceiling is ----Uneven rise(2)(4) Uneven run(2)(4) loose step(s) (2)(4) See Report Summary for more information Notice: The inspector does not determine the effectiveness of any system installed to control or remove suspected hazardous substances* No engineering is performed during this inspection * PRO VIEW PROPERTY INSPECTION ROOF Page 7 KEY: REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information Roof Style: Access Method: Main Roof Hip and Gable Walked Viewed from ladder* Not fully visible due to: Height 19 Main Roof N/A R/I (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Flat Slope Second Roof ----Viewed from ground* With binoculars* Weather Snow Type Debris Roof Covering is: ----Inspection is limited* ----# of layers: Concrete Tile 1 Appear serviceable Defective* Unsafe* Worn* Near end of lifespan* Not fully visible* General condition favorable with signs of weathering and aging-regular maintenance and inspection advised.* Roof material appears improperly installed (2) Holes/opening Exposed Deteriorated membrane Recommend further evaluation* See Photo Summary Page See Report Summary for more information 20 Second Roof Appear serviceable N/A R/I Defective* Roof Covering is: Rolled Roofing Unsafe* Worn* # of layers: 1 Not fully visible* Near end of lifespan* General condition favorable with signs of weathering and aging-regular maintenance and inspection advised.* Roof material appears improperly installed (2) Recommend further evaluation* See Photo Summary Page Holes/openings(2) Exposed(2) Deteriorated membrane(2) See Report Summary for more information Notice: Roofs of this material are often not walked on to avoid causing damage. Not all tiles/slates are checked for attachment.* Inspection is limited* 21 ----Appear serviceable N/A R/I Defective* Roof Covering is: Unsafe* # of layers: -- ----- Worn* Near end of lifespan* Not fully visible* General condition favorable with signs of weathering and aging-regular maintenance and inspection advised.* Roof material appears improperly installed (2) Holes/openings (2) Exposed (2) Deteriorated membrane (2) Recommend further evaluation* See Report Summary for more information Roof Notes No leaks observed Entry Column(s) Type: ----Roof penetrations serviceable Condition: ----Non Functional* Worn* Near end of lifespan*(2) See Photo Summary Page See Report Summary for more information Notice: The report is an opinion of the general quality and condition of the roof.* The Inspector cannot, and does not, offer an opinion or warranty and to whether the roof has leaked in the past, or may be subject to future leakage. Notice: The report is an opinion of the general quality and condition of the roof.* 22 Exposed Flashings N/A R/I Defective* Unsafe* Appear serviceable Vent caps appear serviceable None Appears serviceable Skylights Recommend further evaluation* See Photo Summary Page Worn* Near end of lifespan* Not fully visible* Wall/trim flashings appear serviceable Damaged(2) Non professionally installed(2) No visible flashing at: ----- See Report Summary for more information Notice: Determining the presence of asbestos or hazardous materials is beyond the scope of this inspection.* Roofs, skylights and flashing are not water tested for leaks.* Notice: Tenting a home for fumigation may cause damage to roofs -- recommend reinspection for damage after tenting is completed.* PRO VIEW PROPERTY INSPECTION PLUMBING Page 8 KEY: (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 23 Main Line N/A (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Main pipe Copper Water pressure was ----- R/I REPORT # : JONES 05112015 Size: 1" Pressure: 65 PSI AM PM Appear serviceable Defective* Unsafe* Worn* Near end of lifespan* Not fully visible* Front of House Not located* Operational Not operational (2) Not inspected* Main Valve Location Water softener loop installed not Water was off at the time of inspection, recommend further evaluation* Recommend further evaluation* The main water meter was checked for leaks, no leaks observed. See Photo Summary Page 24 Supply Lines See Report Summary for more information N/A Supply lines appear to be Copper R/I Appear serviceable Defective* Functional Flow appears serviceable No leaks observed Unsafe* Worn* Near end of lifespan* Exposed lines appear properly insulated Hardwater, recommend softener* Recommend further evaluation* No Cross connection(s) were not observed Observed lines visually appear to be See Photo Summary Page Not fully visible* N/A Yes ----- See Report Summary for more information Notice: Underground pipes or pipes inside walls cannot be judged for size, leaks or corrosion.* Water quality testing or testing for hazards such as lead is not part of this inspection.* Notice: Be advised that some "Polybutylene" plastic piping systems have experienced documented problems. 25 Waste Lines N/A Appear serviceable Waste lines appear to be: ABS R/I Defective* Unsafe* Worn* Near end of lifespan* Not fully visible* All vents/traps not fully visible* No leaks observed Functional Drainage appears serviceable Recommend further evaluation* Observed lines visually appear to be; ----- See Report Summary for more information Notice: City sewer service, septic systems and all underground pipes are not a part of this inspection. Future drainage performance is also not determined.* Be advised that some "ABS" plastic piping systems have experienced documented problems. Contact the manufacturer or plumbing expert for further information and evaluation.* 26 Fuel System N/A Shut Valve Location: R/I Northwest Fuel type is Natural Gas Appear serviceable Unsafe* Recommend further evaluation* Pipes appears properly supported Fuel system was not on for inspection, did not inspect gas applicances* Defective* Shutoff valve appears serviceable Worn* Near end of lifespan* Not fully visible* See Report Summary for more information Notice: Underground piping & fuel tanks cannot be judged. Pipes inside walls or pipes concealed from view cannot be judged and the inspector does not perform tests for gas leaks or pipe size.* Type Gas Capacity 50 Gallons Location B ----Type ----Capacity ----Defective* Unsafe* Worn* Near end of lifespan* Not fully visible* Appears serviceable Pilot system appears serviceable Combustion air appears serviceable Gas shutoff valve(s) appear serviceable Heater in garage is not on 18" raised platform* (5) Water Shutoff Valve: installed (no test) appears serviceable Temperature Pressure Relief Valve: installed (no test) Gas Thermocouple appears serviceable Vents and Flues: appears serviceable Recommend a catch pan with an exterior routed drain line* Recommend protecting heater from physical damage* Recommend further evaluation* Model # M45036FBN 27 Water Heaters See Photo Summary Page N/A R/I Location A Garage See Report Summary for more information Notice: Estimate of remaining life is not part of this inspection. Solar systems are not part of this inspection. Hot water recalculating pumps/systems are not part of this inspection.* PRO VIEW PROPERTY INSPECTION HEATING Page 9 KEY: REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 28 Description N/A R/I (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Approximate BTU's Unit A Air Handler A Attic Heating Type: Forced air Fuel Type: Natural gas Recommend further evaluation* Unit B 50,000 30,000 Air Handler B Attic Heating Type: Forced air Fuel Type: Natural gas ELECT DISC: Present Unit C ----- Air Handler C Heating Type: Fuel Type: Missing ----------------- Damaged* See Report Summary for more information Notice: If a fuel burning heater / furnace is located in a bedroom, we recommend evaluation by a qualified heating contractor for safety and air volume requirements.* 29 Condition N/A R/I System(s) appear serviceable Not Functional Unsafe Worn Recommend further evaluation* Aging ----- Near end of lifespan Damage See Report Summary for more information Notice: Inspector does not light pilots. If pilots are "OFF" , a full inspection is not possible. TRANSACTION. * 30 Venting Appears serviceable N/A R/I It is suggested that heating systems be activated and fully inspected PRIOR TO CLOSE OF Not accessible* ----- Unable to fully inspect vent pipe* Defects* Recommend further evaluation* See Report Summary for more information 31 Combustion Appears serviceable N/A R/I Defects* Air supply ----- ----Recommend further evaluation* ----- See Report Summary for more information 32 Burners Appears serviceable N/A R/I ----- Closed system / unable to inspect* Defects* Recommend further evaluation* See Report Summary for more information Notice: The inspector is not equipped to thoroughly inspect heat exchangers for evidence of cracks or holes, as this can only be done by dismantling the unit or other technical procedures.* Some furnaces are designed in such a way that inspection is almost impossible .* Safety devices are not tested by this company .* 33 Distribution Appears serviceable N/A R/I Defects* Type: Ducts & Registers Recommend further evaluation* ----- Each room is cooled by the following HVAC system Each room is heated by the following HVAC system Air ducts not fully visible* Heat Pump Air Conditioning Heat Pump Forced Air Furnace Evaporative Cooling Wood Burning See Report Summary for more information Notice: Asbestos materials have been commonly used in heating systems.* Determining the presence of asbestos can ONLY be performed by laboratory testing and is beyond the scope of this inspection.* PRO VIEW PROPERTY INSPECTION Page 10 KEY: HEATING & AIR CONDITIONING (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 34 Normal Controls N/A R/I REPORT # : JONES 05112015 (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Unable to inspect* Thermostat(s) appears serviceable Recommend further evaluation* Utilities off* Automatic safety controls ----- See Report Summary for more information Notice: Thermostats are not checked for calibration or timed functions.* 35 Air Filter N/A Appears serviceable R/I Adequacy, efficiency or even heat distribution of the system through the house is not part of this inspection. * Missing* Wrong size* ----- Defects* Unable to inspect* Recommend further evaluation* See Report Summary for more information Notice: Electronic air cleaners, humidifiers and dehumidifiers are beyond the scope of this inspection. * Have these systems evaluated by a qualified individual. * 36 HVAC Notes Split system N/A R/I Recommend complete system evaluation (2) Heat pump heating and cooling Gas Furnace and A/C See Report Summary for more information Notice: Verification of the location or condition of underground fuel storage tanks is not part of this inspection.* Environmental risks, if any, are not included. * Notice: Asbestos materials have been commonly used in heating systems.* Determining the presence of asbestos can ONLY be performed by laboratory testing and is beyond the scope of this inspection.* 37 Evap Cooler & 38 A/C Condensor N/A Appears serviceable Defects* R/I Recommend further evaluation* Location(s) Unit A Northwest side Type: Central air conditioning ELECT DISC: Present Missing B Northwest side C ----Power: 120volt ----Damaged* 240volt Unit is not level* See Report Summary for more information AIR HANDLER; ----Air handler appears serviceable ----Coils appear serviceable Coils not inspected due to; Limited or no access Sealed unit Could not open Unit AB* No power - unable to test* ----Air temperature split is: -----13 POWER: 120 Volts 240 Volts Appears serviceable Unit AB* CONDENSATE LINE: Line not fully visible* N/A Condensate line installed ----into floor drain Terminates exterior Terminates sink drain Terminates: Appears serviceable Secondary pan active(2) Unit AB* No trap in line* ----Unit AB* N/A Insulation installed on-lines Insulation damaged* ----REFRIGERANT LINES: Lines not fully visible ----Insulation deteriorated* ----- Heating / Air Comments DATA PLATE: See Photo Summary Page See Report Summary for more information Notice: The inspector does not perform pressure tests on coolant systems; therefore no representation is made regarding coolant charge or line integrity. Subjective judgment of system capacity is not part of the inspection. PRO VIEW PROPERTY INSPECTION ELECTRICAL Page 11 KEY: (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 39 Service N/A R/I REPORT # : JONES 05112015 (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Type: Overhead Underground Number of Conductors 3 NOT DETERMINED 120V* 240V AMP 200 Appear serviceable Defects* Deterioration* Unsafe* Near end of lifespan* Main Disconnect located at Main Panel Main Panel Disconnect by Circuit breaker Fuse Grounding system visible and appears serviceable Recommend further evaluation* See Report Summary for more information 40 Main Panel Appear serviceable N/A Panel rating Location Northwest side Not verified 200 Power was off, recommend inspection after power is turned on* Deterioration* Unsafe* Near end of lifespan* Not accessible* R/I Defects* See Report Summary for more information Notice: Six or fewer breakers usually do not require a main breaker, however this may indicate minimal electrical capacity.* If the service amperage is less than 100, upgrade may be needed to operate larger electrical appliances* 41 Conductors N/A 42 Sub-panel(s) N/A Appears serviceable 43 Panel Notes R/I SERVICE WIRES WIRING METHOD R/I #B-Location ----- Defects* N/A R/I Copper BRANCH WIRE Copper Non-Metallic Cable Appears serviceable #C-Location ----#D-Location ----- Neutral and ground wires connected( ----Overcurrent Protection by; Breaker Recommend further evaluation* Fuse Antioxidant not visible on aluminum wire connections* Main Panel(s) appear(s) serviceable Improper wiring at panel# (2): ----Overfusing fuse/breaker size too large for wire panel #(2): Aluminum wiring noted at the general 120volt circuits(2) (Aluminum connections should be checked by a licensed electrician) * Missing clamp on wire(s) panel #(2)(4): ----Recommend further evaluation* Breaker is off at panel #* ----Panel bond is not provided for safety at panel #(2): Common wires do not have individual lug at bus bar* Unprotected opening(s) in panel # (2): ----Breakers Fuses not labeled #*: ----Opening(s) dead front cover(s) at panel #*(2)(4): ----- See Report Summary for more information 44 Wiring Notes Appears serviceable N/A R/I Sample of switches and outlets tested appear to be serviceable Grounding and polarity of receptacles within 6' of plumbing fixtures Defects* GFCI(s) (Ground Fault Circuit Interrupters) GFCI(s) responded to test GFCI(s), (a safety device for outlets near water) recommended (2)(5) ----GFCI(s) not operational (2)(4) at: Recommend further evaluation* See the following sections for additional electrical items in need of repair (if checked); Rooms Electric Garage Electric Kitchen Electric See Report Summary for more information Notice: Furnishings may prevent testing of all outlets and switches* PRO VIEW PROPERTY INSPECTION INTERIOR Page 12 KEY: REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information Room Location A) Family B) Formal C)Office D) Bed1 E) Bed2 F) Living G) Kitchen H) Laundry I) garage J) Master K) L) M) N) 45 DOORS (Entry) Hardware (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring N/A ----- R/I Appears serviceable Doorbell operational Recommend further evaluation* Jamb Rubs Wx Stripping serviceable See Report Summary for more information See Photo Summary Page 46 & 47 DOORS (Interior & Exterior) Doors serviceable except Closet doors serviceable except Sliding doors serviceable except Screen doors serviceable except N/A R/I Recommend further evaluation* N/A A B C D E F G H I J K L M N N/A A B C D E F G H I J K L M N N/A A B C D E F G H I J K L M N N/A A B C D E F G H I J K L M N See Report Summary for more information N/A 48 Windows Type: Double pane R/I Windows serviceable except at Screens serviceable except at Recommend further evaluation* Aluminum Sliding N/A A B C D E F G H I J K L M N N/A A B C D E F G H I J K L M N Emergency egress; ----- Window(s) not tempered(4)(5) See Report Summary for more information See Photo Summary Page Notice: Determining condition of all insulated windows is not possible due to temperature, weather and lighting variations. Check with owner for further information. N/A 49 Interior Walls R/I N/A Walls serviceable except at Recommend further evaluation* Type: A Drywall B C Plaster D E Paneling F G H Painted I J K L M N Furnishings prevent full inspection -- do a careful check on your final walkthrough. See Photo Summary Page See Report Summary for more information Notice: The condition of walls behind wallpaper, paneling and furnishings cannot be judged. 50 Ceilings N/A Type: R/I N/A Ceilings serviceable except at Recommend further evaluation* A Drywall B Acoustic Spray C D Column(s) type; E Plaster F G Other H I J K L M N wood frame/drywall appears serviceable See Report Summary for more information Notice: Determining whether acoustic sprayed ceilings contain asbestos is beyond the scope of this inspection. For more information please contact the American Lung Association or an asbestos specialist. 51 Floors N/A Type: R/I Floors serviceable except at Cracked tiles at ----Recommend further evaluation* N/A A Carpet B Tile C D Vinyl E Wood F G ----- H I J K L M N Tile grout lifting or missing in a few areas.* Floor squeaks* Furnishings prevent full inspection -- do a careful check on your final walkthrough. See Report Summary for more information Room Location 52 Fireplace(s) A) Family B) Formal C)Office D) Bed1 E) Bed2 F) Living G) Kitchen H) Laundry I) garage J) Master K) L) M) N) N/A R/I Type: Prefabricated Gas shutoff valve; ----- Appears Serviceable Not Functional* Damaged* Unsafe* Worn* Near end of lifespan* N/A A B C D E F G H I J K L M N Fireplace appears serviceable Wall Switch Ignition Manual light Dirty Flue, Recommend Cleaning* Recommend further evaluation* Damper not provided* Damper not operational* Damper clip missing (4) See Report Summary for more information PRO VIEW PROPERTY INSPECTION INTERIOR Page 13 KEY: (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information Room Location A) Family REPORT # : JONES 05112015 Continued (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring B) Formal C)Office D) Bed1 E) Bed2 F) Living G) Kitchen H) Laundry I) garage J) Master K) L) M) N) N/A 53 Interior Features R/I Wet bar serviceable Recommend further evaluation* N/A A B C D E F G Cabinets serviceable except at; Interior stairs appear serviceable Stair handrails appear serviceable Items installed not inspected: Central vacuum Security system Intercom H I J K L Home network M N Fire sprinklers See Report Summary for more information N/A 54 Smoke Detector R/I N/A N/A Detectors serviceable except at; Detectors missing/damaged at; Recommend further evaluation* Suggest additional detectors in appropriate locations* (5) A A B B C C D D E E F F G G H H I I J J K K L L M M N N Recommend adding carbon monoxide (CO) detectors as a safety upgrade (5) See Report Summary for more information 55 Laundry N/A R/I Locations: Laundry Room Closet Garage Basement Not inspected* Not viewed* Unable to test* Ungrounded* Not inspected* Not viewed* N/A No gas provided Unable to view* Vents outside Vents into garage Not provided* Piping (water&waste) serviceable Electrical outlet grounded (120 Volt) 240 volt outlet operational Gas shutoff appears serviceable Dryer venting appears serviceable Not viewed Laundry Sink & Cabinets N/A N/A N/A N/A Laundry sink(s) Laundry sink cabinet(s) Laundry wall cabinet(s) Laundry exhaust fan Recommend further evaluation* How Inspected: Damaged* See Report Summary for more information N/A Entered Defective* Defective* Damaged* Noisy* W/D Model#s See Photo Summary Page 56 Attic Appear serviceable Appear serviceable Appear serviceable Appears serviceable Roof Frame: Truss Rafter Framing 2X 4 Ceiling Frame: 2X 4 Truss Joist Framing Location Closet Roof/ceiling structures appear serviceable Small stains* Moderate stains (2) Major stains (2) Full R/I Partial Access ----No stains visible Appear serviceable Fire wall appears serviceable Ventilation serviceable No ventilation* Insulation Type Blown In Recommend further evaluation* Unable to determine condition of attic ventilation due to no attic access Approximate depth: 16 inches No insulation* Poor coverage* Air/vapor barrier present Air/vapor barrier not required See Report Summary for more information Room Location A) Family B) Formal C)Office D) Bed1 E) Bed2 F) Living G) Kitchen H) Laundry I) garage J) Master K) L) M) N) Rooms Electrical N/A R/I Recommend further evaluation* Electric outlets serviceable except Light switches serviceable except N/A A B C D E F G H I J K L M N N/A A B C D E F G H I J K L M N Ceiling fans serviceable except Attic electrical items N/A A B C D E F G H I J K L M N Appears serviceable Not viewed* See Report Summary for more information PRO VIEW PROPERTY INSPECTION GARAGE Page 14 KEY: REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information GARAGE / CARPORT: 57 Floor N/A (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Type: N/A R/I Appears serviceable Recommend further evaluation* Attached Common cracks Detached Carport Defects* ----- Epoxy coating No cracks found Not fully visible* See Report Summary for more information N/A 58 Firewall / Ceiling R/I Appears serviceable Defects* Recommend further evaluation* Not fully visible* Does not appear fire rated (4) Common cracks Moisture stains* Damaged* See Report Summary for more information 59 Ventilation N/A R/I Appears serviceable Recommend further evaluation* See Report Summary for more information N/A 60 Door To Interior Type: R/I Appears serviceable Defects* Bad Weatherstripping Recommend further evaluation* Solid Rated Door Hollow Core (Non-Fire Resistive)* Pet door interrupts integrity of fire door (2)(4) Door does not Self closer operational Closer non operational(4) Closer not installed(5) See Report Summary for more information 61 Exterior Door N/A R/I Appears serviceable N/A Garage exterior door closer Needs adjustment* Defects* Appears serviceable Inoperative* Not installed* Recommend further evaluation* See Report Summary for more information See Photo Summary Page 62 Vehicle Door(s) N/A Type: R/I Roll Up Tilt-Up Sliding N/A Appears serviceable Defects* Needs adjustment* Needs balancing* Rollers damaged(2) Tracks damaged(2) Tension cable damaged(2) Door weather stripping serviceable Door weather stripping damaged* Recommend further evaluation* See Report Summary for more information See Photo Summary Page 63 Automatic Opener N/A Recommend further evaluation* R/I Appears serviceable Non-operational* Not tested* Photo sensor(s): Appears serviceable Self Reverse: Appears serviceable See Report Summary for more information 64 Electrical N/A Improper wiring (2)(4) Outlets serviceable R/I Appears serviceable Defects* Recommend further evaluation* Exposed wiring subject to damage *(4) Extension cords used as permanent wiring (2)(4) Outlet(s) are inaccessible* Outlet(s) defective(2) GFCI appears serviceable See Photo Summary Page See Report Summary for more information 65 Comments Garage cabinets if installed were not inspected.* Occupant belongings block view of entire garage-unable to fully inspect.* Do a careful check on your final walk-through.* See Report Summary for more information Notice: Determining the rating of fire walls is beyond the scope of this inspection PRO VIEW PROPERTY INSPECTION KITCHEN Page 15 KEY: REPORT # : JONES 05112015 (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 66 Kitch. Sink(s) Sink(s) Faucet(s) N/A R/I (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Recommend further evaluation* Appears serviceable Appear serviceable Hot & cold water reversed*(4) Minor wear Heavy wear* Chipped* Non-operational(2) Defective(2) Faucet functional flow appears Sink is loose* Slow draining* Spray wand defective* Drain functional flow appears See Report Summary for more information 67 General N/A R/I Counter Type: Tile Laminate Granite Not fully visible* Appear serviceable Damaged* Lightly worn Moderate damage* Heavy wear* Countertops Appear serviceable Minor wear Moderate damage* Heavy wear* Heavy damage* Cabinets: Moisture stains below sink* Moisture damage below sink* Restricted view below sink* ----Other features/appliances present with limited inspection include:* Recommend further evaluation* See Report Summary for more information 68 Disposal N/A R/I Appears serviceable Defective* Unsafe* Worn* Switch is in a hazardous location (2)(4) Recommend further evaluation* Splash guard damaged* Near end of lifespan* Not fully visible* Unit makes unusual noise* Missing wire clamp at disposal* See Report Summary for more information 69 Range/Cooktop N/A R/I # of ovens: 1 Gas Electric Combination Electric Ignition Appears Serviceable Defective* Unsafe* Worn* Near end of lifespan* Not fully visible* Oven door(s) appear(s) serviceable Not Inspected (power/gas off)* Door(s) gasket(s) appear(s) serviceable Anti tip missing(4) Micro/Hood Model # Exhaust ventilation ---JE1860CB=003 Gas shutoff valve A/S Gas shutoff valve installed Gas shutoff not installed Gas shutoff defective(2)(5) RModel# Recommend further evaluation* Clock appears serviceable See Report Summary for more information Notice: Self and/or continuous cleaning operations, clocks, timing devices, lights and thermostat accuracy are not tested during this inspection.* Appliances are not moved.* 70 Dishwasher N/A R/I Recommend further evaluation* Appears serviceable Defective* Unsafe* Worn* Door seals appear serviceable Soap door inoperative* Air gap device High loop DRAIN LINE INSTALLATION: Model # GSD6600GOOCC Near end of lifespan* Not fully visible* Unit is not secured to cabinets* None Improper* See Report Summary for more information Notice: Determining the adequacy of washing and drying functions of dishwashers is not part of this inspection.* 71 Kitchen Electric N/A R/I Appears serviceable Defects* GFCI appear serviceable GFCI inoperative(2)(4) GFCI recommended ALL countertop outlets(2)(4) Dishwasher outlet appears serviceable Dishwasher outlet defective(2)(4) Recommend further evaluation* Model # Refrigerator GE PROFILE See Report Summary for more information Notice: Refrigerators, freezers and built-in ice maker are not part of this inspection* PRO VIEW PROPERTY INSPECTION BATHROOMS Page 16 KEY: (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information LOCATION: Bath A Guest 72 Toilet N/A B Bedroom #1 R/I Appears serviceable Toilet loose at floor* Loose toilet tank* Does not flush properly* REPORT # : JONES 05112015 (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring C Bedroom #2 D Master Recommend further evaluation* A A A A B B B B E F C C C C D D D D E E E E F F F F C C C C C C C C C D D D D D D D D D E E E E E E E E E F F F F F F F F F C D E F See Report Summary for more information 73 Sink N/A R/I Recommend further evaluation* Appears serviceable Functional flow appears serviceable Functional drainage appears serviceable Faucet leaks* Sink cracked* Slow draining* Sink stopper defective or missing Counter & cabinets appears serviceable Damage to counter* A A A A A A A A A B B B B B B B B B See Report Summary for more information 74 Vent / Heat N/A R/I Recommend further evaluation* Appears serviceable A B Venting by window only No bathroom venting* See Report Summary for more information 75 Bathtub N/A R/I Recommend further evaluation* A A A A A Damage to tub* Faucet appears serviceable Drain appears serviceable Whirlpool not tested(2) Tub is not applicable to this bathroom N/A C C C C C D D D D D E E E E E F F F F F C C C C C C C C C C D D D D D D D D D D E E E E E E E E E E F F F F F F F F F F See Report Summary for more information See Photo Summary Page 76 Shower B B B B B R/I Recommend further evaluation* A Appears serviceable A Functional flow appears serviceable A Functional drainage appears serviceable A Moisture damage to wall (2)(3) A Shower enclosure appears serviceable A Shower door appears serviceable A Shower head drips(2) A Caulking needed at enclosure* A Shower diverter in need of repair at A Shower is not applicable to this bathroom B B B B B B B B B B See Report Summary for more information Notice: Determining whether shower pans are watertight is beyond the scope of this inspection.* PRO VIEW PROPERTY INSPECTION Page 17 KEY: POOL / SPA & EQUIPMENT (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information 77 Pool / Spa Type N/A (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring Below Ground Plaster / Gunite R/I REPORT # : JONES 05112015 Water Feature Spa only Above Ground Pebble Finish Notice: Pool and spa bodies are beyond the scope of this inspection. * The information regarding the type of pool/spa is given as a courtesy only. N/A 78 Heater R/I Gas Appears serviceable Pressure Limit Switch Gas/breakers off* Appears serviceable Body bond Present Missing* Burners serviceable Burners See Photo Summary Page Pressure gauge Bleeder valve Sanitizing System Solar Panels (not tested) Gas shut-off not provided (2) Could not determine operation* Inoperative (2) Could not determine operation* Not installed* Corroded* Damaged* Recommend further evaluation* See Report Summary for more information N/A 79 Filter Electric R/I Cartridge Filter Appears serviceable Appears serviceable Chlorine Bromine Diatomaceous Earth Filter Sand Filter Inoperative* Broken glass* Missing* Cartridge FIlters not inspected Inoperative* None provided* Recommend further evaluation* Salt None found* Equipment pad serviceable Pad damaged* See Report Summary for more information 80 Pumps N/A R/I Pumps: Circulation Spa Jet pump Vacuum pump Recommend evaluation(2) Circulation pump operated when tested Pump did not operate (2) Defective (2) Body bond present No body bond(5) Loose body bond* Recommend adding body bond wire(5) Spa Jet pump operated when tested Pump did not operate (2) Defective (2) Body bond present No body bond(5) Loose body bond* Recommend adding body bond wire(5) Vacuum pump operated when tested Pump did not operate (2) Defective (2) Body bond present No body bond(5) Loose body bond* Recommend adding body bond wire(5) See Photo Summary Page See Report Summary for more information 81 Blowers N/A R/I Air Bubbler Supplemental Jet Pump Recommend further evaluation* Blower operated when tested Blower did not operate (2) Not tested due to:* See Report Summary for more information Main Panel At Equipment N/A R/I Breaker Location: 82 Electrical Wiring: Liquid Tite Flex Rigid Conduit NM Cable (Romex) (2) Wiring appears serviceable Improper wiring noted (2)(4) Improper conduit (2) Deteriorated conduit (2) Pool Lights Appears serviceable Inoperative (2) Could not determine operation* Pool GFCI Appears serviceable Inoperative (2) Could not determine operation* Spa Lights Appears serviceable Inoperative (2) Could not determine operation* Spa GFCI Appears serviceable Inoperative (2) Could not determine operation* On Off at time of inspection Power is off - could not verify operation* Timers: Equipment Equipment timer(s) serviceable Inoperative (2) Unable to determine(2) No wire protector* Rusted Damaged Remote switches appear operational Recommend further evaluation* See Report Summary for more information 83 General N/A R/I Fencing Barrier for Pool/Spa: Self-closing/latching Gate: Yes Yes No* (Caution) (5) No* (Caution) (5) Major cracks (2) Inoperative* (5) Inoperative* (5) Recommend further evaluation* Coping appears serviceable Lifting* Settling* Cracked* Surrounding deck/concrete appears serviceable Common cracks Pool cleaning system is: Vacuum system Appears serviceable Anti siphon appears serviceable appears serviceable Pool auto fill: Will need to fill pool manually by hose.* Anti vortex drain: Aerator: appears serviceable appears serviceable not installed (5) missing (5) See Photo Summary Page See Report Summary for more information Page 18 Pro View Property Inspection REPORT SUMMARY (1) Recommend evaluation by a structural engineer (2) Recommended evaluation and repairs by a licensed contractor (3) Refer to qualified termite report for further information (4) This item is a safety hazard - correction is needed (5) Upgrades are recommended for safety enhancement * This item warrants attention/repair or monitoring This Report Summary is provided as a courtesy for quick access to the information within the inspection report. It is not intended as a substitute for reading the inspection report. Client: Nancy Jones 1. Driveway Report #: JONES 05112015 GROUNDS Page 4 Serviceable 2. Sidewalks Serviceable 3. Retaining Walls N/A 4. Patio Common cracks up to 1/4" were noted in the patio slab at the time of the inspection. 5. Patio Cover The awning attached to the patio is damaged and at end of life. Should be replaced. Also it appears the ceiling over the patio has been patched. Possibly to install an outdoor speaker system. 6. Decks/Porches N/A 7. Fences & Gates The self closing device on the gate, on the northwest side of the house, does not function. All gates and doors with access to the pool area must be self close for safety. Recommend handy man for adjustment. Also several blocks on the southeast fence at the top are loose, and the grout along the bottom of the wall is cracking. (Cracks in the grout at the bottom have no effect on the strength of the wall.) Also the metal fence at the rear of the yard needs to be painted. Monitor and repair as needed. 8. Exterior Stairs EXTERIOR Page 5 N/A 9. Exterior Walls Common cracks up to 1/8" were found in the exterior stem wall, at the time of the inspection, on the southeast back corner. Recommend sealing to prevent water penetration.* Also on the front of the house there is a flag holder that has damaged the stucco. Recommend removal of holder and repair of stucco. Qualified handy man. 10. Trim /Eaves, Soffits & Fascia Serviceable 11. Chimney Serviceable 12. Sprinklers Recommend adding anti-syphon device to the irrigation system for water safety, anti-syphon devices prevent back flow of PRO VIEW PROPERTY INSPECTION Report # : Jones 05112015 Page 18 Part A 1 © EZ Report Copyright 2011-13 discharged water back into supply water. (4) 13. Hose Faucets Anti siphon type device missing at one or more faucets. This device helps prevent back flow of discharged water into potable water system. Recommend installing anti syphon device for safety (5) Also the faucet on the northwest side of the house had corrosion which indicates there has been a leak. No leaks observed at time of inspection. 14. Gutters & Downspouts Recommend adding gutters and down spouts for proper drainage, gutters and down spouts are used to help direct water away N/A from the buildings foundation to help prevent moisture damage. Recommend installing operational gutters and down spouts * 15. Lot Drainage / Grading FOUNDATION Page 6 Plants are against the foundation. Water has no drainage. Recommend removal. 16. Slab on Grade, 17. Raised Foundation, 18. Basement Minor cracks were found in the stem wall of the slab foundation at the time of the inspection, at the southeast corner. Recommend sealing to prevent moisture from entering. Floor Construction Comments Serviceable Basement Stairs Comments N/A 19. Main Roof ROOF Page 7 Several of the tile have been repaired. The cement cap for the tile over the entrance is beginning to crack. Also the flashing around the bottom of the chimney and the entrance is rolled roofing which appears to be at or near end of life. Recommend licensed roof contractor for evaluation. Several valleys of the roof have some debris build up. Recommend removal for better drainage. 20. Second Roof The roof over the patio is rolled roofing. It appears to be worn and at, or near, end of life. Recommend licensed roof contractor for evaluation. 21. Third Roof Roof Notes NOTE: The life span of the roofing paper under roof tiles cannot be determined, typical life span is less than 20 years. 22. Exposed Flashing Flashing around bottom of chimney is rolled roofing. It appears to worn and at, or near, end of life. Recommend licensed roofing contractor for evaluation. 23. Main Line PLUMBING Page 8 Moisture was observed on the stem wall below the main water supply pipe. This indicates a possible water leak inside the wall. The paint on the stem wall is peeling due to constant moisture. Recommend licensed plumber for evaluation. 24. Water Supply Lines Serviceable 25. Waste Lines Serviceable at time of inspection. 26. Fuel System All of fuel lines were not visible. 27. Water Heater(s) Area around bottom of water heater appears to have water damage. Possibly from a prior leak. No leaks observed. Water heater PRO VIEW PROPERTY INSPECTION Report # : Jones 05112015 Page 18 Part A 2 © EZ Report Copyright 2011-13 is serviceable. 28. Description HEATING Page 9 All rooms are heated by forced air 29. Condition Heating was not tested due to outside temperature. 30. Venting Unable to fully inspect the furnace vent pipe due to limited view of piping. 31. Combustion Air Heating was not tested due to outside temperature. 32. Burners The furnace is a closed system --burners not visible for inspection. 33. Distribution Serviceable. 34. Normal Controls HEATING Page 10 Serviceable 35. Air Filters Suggest changing or cleaning the air filters for better HVAC operation. 36. Heating Notes Serviceable 37.& 38. Evaporative Cooler/Air Conditioner Manufacture date for both units is March of 2003. Life span for these units in this part of the United Stated is 8 to 10 years. Some units fall short of this data and others well exceed. Both units are showing signs of wear. Monitor and replace as needed. Heating and Air Comments Primary condensation lines were plumbed together in the attic. This could be an issue if one line became blocked. Secondary lines were plumbed separately. Also catch pan on unit B (5 ton) had rust in the bottom which indicates standing water which could have been a prior blocked condensation line. No leaks observed. Insulation on the refrigerant lines is deteriorating. This effects the temperature of the gas in the lines. Recommend licensed HVAC company for evaluation/repairs. 39. Electric Service ELECTRICAL Page 11 INTERIOR Page 12 Serviceable 40. Main Panel Serviceable 41. Conductors,42. Sub-panel(s),43. Panel Notes Serviceable N/A 44. Wiring Notes Serviceable 45. Entry Doors The entry door rubs the jam when opening or closing. Also there were moisture stains on the molding, at the bottom, to the left, and right, of the entry. This could indicate a prior leak from damaged weather stripping. Weather stripping appeared to be serviceable. Monitor and repair as needed. PRO VIEW PROPERTY INSPECTION Report # : Jones 05112015 Page 18 Part A 3 © EZ Report Copyright 2011-13 46. & 47 . Interior & Exterior Doors The self close device on the sliders in bedroom #2, and the master bedroom was present, but did not work. Doors with access to pool area must self close for safety. Recommend qualified handy man for adjustments/repairs. 48. Windows The window in the formal dinning area is damaged. The screens in the front family room and the living room do not fit closely to the window frame. Also the inner seal in several of the windows is sagging. At present the seal from the outside temperature is still intact, however they will begin to leak over time. Recommend licensed contractor for evaluation/repairs. Also several latches on the shutters are broken. Monitor and repair as needed. 49. Interior Walls In bedroom #2, the window had cracks in the drywall at the top on both sides. Monitor and repair as needed. 50. Ceilings Serviceable 51. Floors Furnishings prevented full inspection -- do careful check on your final walkthrough. 52. Fireplace Serviceable 53. Interior Features INTERIOR Continued Page 13 Cabinets were serviceable 54. Smoke Detectors All smoke detectors had green service lights. 55. Laundry Molding at the top of the wall cabinets was coming loose. Recommend a qualified handy man for replacement/repairs. 56. Attic Serviceable Rooms Electrical Serviceable GARAGE 57. Floor Page 14 The garage floor is not fully visible due to the occupants belongings. 58. Firewall/Ceiling The attic access/pulldown does not appear to be fire rated. Recommend adding fire resistant material for safety. (4) 59. Ventilation Serviceable 60. Door to Living Space Serviceable 61. Exterior Door Recommend further evaluation* The door had moisture stains on the floor, on the inside, and the base molding on the right side is separating from the wall. The bottom sill of the door on the outside needs to be caulked. All indicate a damaged weather seal on the bottom of the door. Recommend evaluation/repair by a qualified handy man. 62. Vehicle Door Outside weather stripping around single vehicle door is beginning to crack. Monitor and replace/repair as needed. 63. Automatic Opener PRO VIEW PROPERTY INSPECTION Report # : Jones 05112015 Page 18 Part A 4 © EZ Report Copyright 2011-13 Serviceable 64. Garage Electrical An extension cord was hanging from the ceiling as permanent wiring for a work light. Recommend a electrician to hard wire the light fixture for safety. 65. Garage Comments Garage cabinets not inspected. 66. Sink(s) KITCHEN Page 15 No stopper for left side of sink. Serviceable 67. Kitchen General Not able to inspect behind refrigerator. Wall was sealed. All serviceable. 68. Garbage Disposal Serviceable at time of inspection. 69. Range / Oven / Cooktop Serviceable 70. Dishwasher Serviceable 71. Kitchen Electric Serviceable 72. Toilet BATHROOMS Page 16 Minor corrosion on shut off valve for toilet in bedroom #1. No leaks observed. Serviceable 73. Sink The sink drain stopper did not operate properly in bedrooms #1 and #2. * 74. Ventilation / Heat Serviceable 75. Bathtub The faucet head for the tub in bedroom #2 was loose. Also small area on deck around tub in the master bath should be caulked to prevent moisture between tub and cabinet. Monitor and repair as needed. 76. Shower The shower diverter did not operate normally in bedroom #2. Monitor and repair as needed. (2) 77. & 78. Body Type, Heater POOL / SPA Page 17 N/A 79. Filter Serviceable 80. Pumps The body bond wire on the 2 pumps was rusted and broken. Recommend a licensed electrician for repair. 81. Blowers N/A 82. Electrical Serviceable 83. General Comments PRO VIEW PROPERTY INSPECTION Report # : Jones 05112015 Page 18 Part A 5 © EZ Report Copyright 2011-13 Common cracks/chips found in the cool deck around pool, and in the coping. Nothing major. Monitor and repair as needed. Pool appears to have shading on the bottom. May need to be drained and acid washed. Also faucet attached to pool equipment leaks when pool pump is in operation. Recommend qualified pool/spa company for evaluation. PRO VIEW PROPERTY INSPECTION Report # : Jones 05112015 Page 18 Part A 6 © EZ Report Copyright 2011-13 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 1 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 48. Windows The inner seal in several of the windows is sagging. At present the seal from the outside temperature is still intact, however they will begin to leak over time. Recommend licensed contractor for evaluation/repairs. 2 Related to: 48 Windows The inner seal in several of the windows is sagging. At present the seal from the outside temperature is still intact, however they will begin to leak over time. Recommend licensed contractor for evaluation/repairs. Pro View Property Inspection Page 19 Part A 1 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 3 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 23. Main Line Moisture was observed on the stem wall below the main water supply pipe. This indicates a possible water leak inside the wall. The paint on the stem wall is peeling due to constant moisture. Recommend licensed plumber for evaluation. 4 Related to: 23. Main Line Moisture was observed on the stem wall below the main water supply pipe. This indicates a possible water leak inside the wall. The paint on the stem wall is peeling due to constant moisture. Recommend licensed plumber for evaluation. Pro View Property Inspection Page 19 Part A 2 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 5 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 13. Hose Faucets Anti siphon type device missing at one or more faucets. This device helps prevent back flow of discharged water into potable water system. Recommend installing anti syphon device for safety (5) 6 Related to: 15. Grading Plants are against the foundation. Water has no drainage. Recommend removal. Pro View Property Inspection Page 19 Part A 3 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 7 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 61. Exterior Door The bottom sill of the door on the outside needs to be caulked. Recommend evaluation/repair by a qualified handy man. 8 Related to: 7. Fences & Gates The self closing device on the gate, on the northwest side of the house, does not function. All gates and doors with access to the pool area must be self close for safety. Recommend handy man for adjustment. Pro View Property Inspection Page 19 Part A 4 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 9 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 62. Vehicle Door Outside weather stripping around single vehicle door is beginning to crack. Monitor and replace/repair as needed. 10 Related to: Faucets Anti siphon type device missing at one or more faucets. This device helps prevent back flow of discharged water into potable water system. Recommend installing anti syphon device for safety (5) Also faucet on northwest side of house has corrosion which indicates there has been a leak. No leaks observed at time of inspection. Pro View Property Inspection Page 19 Part A 5 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 11 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 94. Heating and Air Comments Insulation on the refrigerant lines is deteriorating. This effects the temperature of the gas in the lines. Recommend licensed HVAC company for evaluation/repairs. 12 Related to: 94. Heating and Air Insulation on the refrigerant lines is deteriorating. This effects the temperature of the gas in the lines. Recommend licensed HVAC company for evaluation/repairs. Pro View Property Inspection Page 19 Part A 6 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 13 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 5. Patio Cover It appears the ceiling over the patio has been patched. Possibly to install an outdoor speaker system. 14 Related to: 5. Patio Cover The awning attached to the patio is damaged and at end of life. Should be replaced. Pro View Property Inspection Page 19 Part A 7 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 15 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 5. Patio Cover The awning attached to the patio is damaged and at end of life. Should be replaced. 16 Related to: 83. General Common cracks/chips found in the cool deck around pool, and in the coping. Nothing major. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 8 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 17 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 83. General Common cracks/chips found in the cool deck around pool, and in the coping. Nothing major. Monitor and repair as needed. 18 Related to: 83. General Common cracks/chips found in the cool deck around pool, and in the coping. Nothing major. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 9 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 19 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 83. General Common cracks/chips found in the cool deck around pool, and in the coping. Nothing major. Monitor and repair as needed. 20 Related to: 83. General Common cracks/chips found in the cool deck around pool, and in the coping. Nothing major. Monitor and repair as needed. Also pool appears to have shading on the bottom. May need to be drained and acid washed. Recommend qualified pool/spa company for evaluation. Pro View Property Inspection Page 19 Part A 10 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 21 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: Grill Area Grout missing on the flagstone on the surface around the grill. Monitor and repair as needed. 22 Related to: Grill Area Grout missing on the flagstone on the surface around the grill. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 11 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 23 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 7. Fences & Gates Several blocks on the southeast fence at the top are loose, and the grout along the bottom of the fence is cracking. (Cracks in the grout at the bottom of the fence have no effect on the strength of the fence.) Also the metal fence at the rear of the yard needs to be painted. Monitor and repair as needed. 24 Related to: 7. Fences & Gates Several blocks on the southeast wall at the top are loose, and the grout along the bottom of the wall is cracking. (Cracks in the grout at the bottom of the wall have no effect on the strength of the wall.) Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 12 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 25 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 9. Exterior Walls On the front of the house there is a flag holder that has damaged the stucco. Recommend removal of holder and repair of stucco. Qualified handy man. 26 Related to: 19. Main Roof Several of the tile have been repaired. Pro View Property Inspection Page 19 Part A 13 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 27 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: Roof Several tile have been repaired. 28 Related to: 19. Main Roof The flashing around the bottom of the chimney and the entrance is rolled roofing which appears to be at or near end of life. Recommend licensed roof contractor for evaluation. Pro View Property Inspection Page 19 Part A 14 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 29 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 19. Main Roof The cement cap for the tile over the entrance is beginning to crack. Recommend licensed roof contractor for evaluation. 30 Related to: 19. Main Roof Recommend licensed roof contractor for evaluation. Pro View Property Inspection Page 19 Part A 15 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 31 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 20. Second Roof The roof over the patio is rolled roofing. It appears to be worn and at or near, end of life. Recommend licensed roof contractor for evaluation. 32 Related to: 22. Exposed Flashing Flashing around bottom of chimney is rolled roofing. It appears to worn and at, or near, end of life. Recommend licensed roofing contractor for evaluation. Pro View Property Inspection Page 19 Part A 16 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 33 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 19. Main Roof Several valleys of the roof have some debris build up. Recommend removal for better drainage. 34 Related to: 45. Entry Doors There were moisture stains on the molding, at the bottom, to the left, and right, of the entry. This indicates a prior leak from damaged weather stripping. Weather stripping appeared to be serviceable. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 17 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 35 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: Shutters The latches on several of the shutters were broken. Monitor and repair as needed. 36 Related to: 48. Windows The screens in the front family room and the living room do not fit closely to the window frame. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 18 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 37 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 75. Bathtub The faucet head for the tub in bedroom #2 was loose. Monitor and repair as needed. 38 Related to: 49. Interior Walls In bedroom #2, the window had cracks in the drywall at the top on both sides. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 19 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 39 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 49. Interior Walls In bedroom #2, the window had cracks in the drywall at the top on both sides. Monitor and repair as needed. 40 Related to: 55. Laundry Filtered water drain pipe had some corrosion. No leaks observed. Pro View Property Inspection Page 19 Part A 20 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 41 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 55. Laundry Molding at the top of the wall cabinets was coming loose. Recommend a qualified handy man for replacement/repairs. 42 Related to: 64. Electrical An extension cord was hanging from the ceiling as permanent wiring for a work light. Recommend a electrician to hard wire the light fixture for safety. Pro View Property Inspection Page 19 Part A 21 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 43 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 61. Exterior Door Garage The door had moisture stains on the floor, on the inside, and the base molding on the right side is separating from the wall. The bottom sill of the door on the outside needs to be caulked. All indicate a damaged weather seal on the bottom of the door. Recommend evaluation/repair by a qualified handy man. 44 Related to: 27. Water Heater(s) Area around bottom of water heater appears to have water damage. Possibly from a prior leak. No leaks observed. Water heater is serviceable. Pro View Property Inspection Page 19 Part A 22 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 45 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 75. Bathtub Small area on deck around tub in the master bath should be caulked to prevent moisture between tub and cabinet. Monitor and repair as needed. 46 Related to: 75. Bathtub Small area on deck around tub in the master bath should be caulked to prevent moisture between tub and cabinet. Monitor and repair as needed. Pro View Property Inspection Page 19 Part A 23 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 47 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 80. Pumps The body bond wire on the 2 pumps was rusted and broken. Also the faucet at the pumps leaks when pump is in operation. Recommend a licensed electrician and pool service for repairs. 48 Related to: 94. Heating and Air Comments Primary condensation lines were plumbed together in the attic. This could be an issue if one line became blocked. Secondary lines were plumbed separately. Also catch pan on unit B (5 ton) had rust in the bottom which indicates standing water which could indicate a prior blocked condensation line. Recommend licensed HVAC company for evaluation/repairs. Pro View Property Inspection Page 19 Part A 24 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 49 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 94. Heating & Air Catch pan on unit B (5 ton) had rust in the bottom which indicates standing water which could indicate a prior blocked condensation line. No leaks observed. Recommend licensed HVAC company for evaluation/repairs. 50 Related to: 16. Slab on Grade Minor cracks were found in the stem wall of the slab foundation, at the southeast corner. Recommend sealing to prevent moisture from entering. Pro View Property Inspection Page 19 Part A 25 Page 19 Inspection Pictures Client: Nancy Jones Schedule Date : Monday, May 11, 2015 51 Subject Property 40451 Congressional Dr. Anthem, Az 85086 Related to: 16. Slab on Grade Minor cracks were found in the stem wall of the slab foundation, at the southeast corner. Recommend sealing to prevent moisture from entering. Pro View Property Inspection Page 19 Part A 26 Congratulations on your new home. Owning a home is one of the biggest investments you will make and one that will need constant monitoring. We have put together a list of items that you may wish to consider to properly maintain your home and to help extend the life of your new home. Let’s start with the outside… POOL/SPA If you have a pool or spa, we recommend having your equipment checked by a licensed pool technician at least once a year. These yearly checks may help reduce premature repair/replacement component costs. (Typical pool inspection costs range from $35 to $50) GRADE/FOUNDATION We recommend periodic inspections of the entire perimeter exterior foundation wall for signs of moisture damage. The number one cause of foundation deterioration is ponding water at the foundation wall. We recommend having the grade slope away from the foundation and a minimum of 4 to 6 inches from the grade to the stucco screed to help keep moisture from penetrating the exterior wall. ELECTRICAL We strongly recommend monthly testing of all GFCI outlets with the test button. This will help identify any faulty circuits that are controlled by the GFCI. (Typical GFCI outlet lifespan are 5 to 10 years) ROOF Periodic visual inspections should be performed of the roofing material to help identify possible water shedding problems. This includes tiles or shingles, roofing paper, flashing and patio roof structures. You may want to visit the attic area occasionally to see if there are signs of moisture damage at the roofing structure. (Typical life expectancy of the roofing material is 12 to 15 years) GARAGE The vehicle door should be checked periodically for proper balancing and lubrication. If a door opener is installed, the automatic reverse function should be checked as well for safety. (Typical life expectancy of the garage door springs is 10 to 15 years, the opener is 10 to 15 years) Now let’s look inside… HVAC Heating, Ventilation and Cooling systems require yearly servicing to ensure the most efficient operation of your system. Air filters should be replaced monthly during the summer months and quarterly during the winter months. Continuous monitoring of the coils condensate lines and secondary drain pan should be performed to identify drain line blockages and to prevent possible damage to the surrounding structure. Some of these coils are located in the attic and may require attic access. We also recommend a programmable thermostat to efficiently operate the HVAC system. (Typical life expectancy of the HVAC system is 10 to 15years) PLUMBING We recommend maintaining a maximum water pressure of 80 psi to prevent premature water fixture leaks. Water pressure may be controlled with the use of a water pressure regulator. All sink faucets should be checked periodically at the water shutoff valves for signs of leakage. Hot water heater pipe connections, soft water pipe connections and washing machine supply hoses should be checked periodically for leakage as well. You may wish to install a water softener if your home does not already have one; this will help reduce mineral deposits throughout your water system as well as help to extend the life of your water fixtures. (Typical life expectancy of water softeners is 10 to 15years, hot water heaters 10 to 12 years and washing machine hoses is 5 years) ELECTRICAL We strongly recommend monthly testing of all GFCI outlets with the test button. This will help identify any faulty circuits that are controlled by the GFCI. (Typical GFCI outlet lifespan are 5 to 10 years) Ongoing maintenance will help extend the life of your new home. We hope that you have found this information helpful.
© Copyright 2024