Static Control Product Catalog http://www.vessel.co.jp/english/staticelectric/ VESSEL, Three Particular Reasons people choose VESSEL 01 1 We have the best selection 2 Our product development aims for user friendliness 3 Our static removal and dust removal specialists improve your quality problems Vessel’s lineup covers a wide range from fan, gun and bar-type air blow ionizers, EPA mats and wrist straps that prevent static discharge, to adhesive mats that prevent the scattering of dust. Our products provide solutions to your static removal and dust removal problems. To provide optimum products for production sites, our designs aim for ease of use. VESSEL aims for user convenience with our product lineup for various applications. Our static removal and dust removal specialists will visit your production site to propose the best available products. Customization is also available upon request. the ionizing and dust elimination expert, helps solve your quality problems. Product quality is an important determination at manufacturing sites. VESSEL has focused on countermeasures against static electricity and dust in relation to quality. Since 2000, we have provided products to remove static and dust. All to help improve our customer’s quality. Let VESSEL, the ionizing and dust elimination experts, help you improve your product quality. 02 Realize ionizing and clean control from your VESSEL’s lineup of reliable and wide ranged Fan Type Nozzle Type Gun Type Mount on a cell workbench, part shelf or belt conveyor. Handle close to far distances by switching the speed. Assemble into manufacturing devices for pinpoint neutralization and dust-elimination within a confined space. Just replace the nozzle to use with various applications. Ideal for air washing and neutralization after part acceptance and before part assembly, as well as for neutralization and dust elimination from resin formed products before painting. <Mini> F6CL-E F6ST-E P06 N-1 N-2 P12 Bar Type Suitable for neutralizing clean rooms, and preventing static buildup on film moving at high speeds. G7R-E P14 BBZ-E P14 <Built-in power supply> C-series P17 <Standard> SFQ9-E P07 <Built-in power supply> B-series F120-E F120S-E P19 P08 <Wide width> CF-30-E P09 <Separate power supply> 3F-12-E SH-series P09 P21 SG-H3 P22 P05 03 P11 P13 P15 fingertips to your toes. static electricity countermeasure products. Ion Parts Cleaner EPA Working Mat Perform air washing within static electricity removal area. Scattered dust is collected with the dust collector to maintain a clean environment. Clean Walker ESD control mats for use in areas where parts are handled, assembled, repaired and tested. Available in ESD control mats and wrist straps. Adhesive mat, set before a clean room, collects dust off soles of work shoes. Non-peeling, washable type. Options Options and replacement parts. <Gel Dust Collection Type> IPC-A4 IPC-A3 P24 Electrode Needle Unit Conductive Rubber Mat P28 Electrode Needle Unit <Clean Walker> CW-900B P32 AC Adapter Filter Standard Nozzle Branch Box Brush Branch Adapter Speed Controller Flared Nozzle Adhesive Gel Sheet Electrode Needle <Dust Collection Chamber built-in Type> IPC20-E P25 <ESD Countermeasure Wrist Straps> EPS-01/01G EPS-03M/S EPS-02M/S EPS-04/B <Clean Walker Easy> CW-900EZ P32 P29 <Separate Dust Collecter Type> IPC40-E P25 IPC-60 P26 <Tray> <Electrostatic Field Meter> EYE-01 EYE-02 P23 Measurement Conditions CW-T900 P32 SDL-01 P30 P27 P31 P33 Ion balance : 300 mm from the front of the device at maximum airflow setting Decay time : 300 mm from the front of the device at maximum airflow setting (given as the time required for the voltage to attenuate from ±1,000 V to ±100V)(Charged plate monitor: 150 mm × 150 mm square, 20 pF) Noise level :1 m from the front of the device at maximum airflow setting ※Measurement values given in this catalog are typical values from a sample unit, and do not guarantee the performance. 04 Why is VESSEL’s fan type our customer’s top choice? 1 High neutralization performance through efficient ion generation Fan Type The high frequency piezoelectric transformer generates large volumes of ions, and eliminates losses caused by recoupling. F6CL-E/F6ST-E High-frequency piezoelectric transformer「Piezzo」 Compact and free installation Pinpoint neutralization Decay time 3.0 sec or less SFQ9-E Dual piezoelectric transformer attains fastest neutralization in this class Decay time 1.2 sec or less F120-E/F120S-E 2 Advanced control technology with steady ion balance The capacity coupling type electrode needle ensures a stable ion balance, and prevents static destruction of the semiconductor. NEW Butterfly louver realizes high-speed neutralization Decay time 1.3 sec or less Electrode Needle Unit CF-30-E High-efficiency cross fan neutralizes over wide range of areas Decay time 1.4 sec or less 3F-12-E Providing wide-range static-erasing on workbench or conveyors Decay time 1.8 sec or less 05 3 Louver cover improves serviceability The cover can be easily removed allowing the electrode needle to be cleaned where it will not contaminate the work environment. Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Ionizing Mini Fan with clip Clean Walker Options Ionizing Mini Fan with stand Clip onto workbench or pillar for pinpoint neutralization Compact fan can be installed anywhere for pinpoint neutralization F6CL-E F6ST-E 77 77 131 Low noise Fan Low noise Fan 142 81 81 EDP No. 621632 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 3.0 sec or less Power supply Fan Speed HI/LOW DC24V LED illumination INCLUDED TRANSFOMER 100-240VAC Electrode needle unit replacement ALARM FAN LOCKUP Directive ALARM H.V. External grounding terminal Install anywhere Easily remove louvers Confirm operation status and electrode tip contamination with built-in light. EDP No. 621631 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 3.0 sec or less Power supply DC24V Fan Speed HI/LOW LED illumination INCLUDED TRANSFOMER 100-240VAC Electrode needle unit replacement ALARM FAN LOCKUP Directive ALARM H.V. External grounding terminal Install anywhere Easily remove louvers Confirm operation status and electrode tip contamination with built-in light. M5 Screw M5 Screw M5 Screw Clip Stand Remove clip when not needed Easy removal Built-in light Remove clip when not needed Easy removal Built-in light Specifications Specifications Model No. F6CL-E Model No. F6ST-E Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 3.5kV Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 3.5kV Power supply and current consumption DC24V±5%/253mA(typ.) Power supply and current consumption DC24V±5%/220mA (typ.) Ion balance within ±10 V Ion balance within ±10 V Decay time 3.0 sec or less Decay time 3.0 sec or less Operating range 150 mm to 600 mm Operating range 150 mm to 600 mm H×W×Dmm H254×W77×D108mm(clip included) H×W×Dmm H142×W90×D82mm(stand included) Weight 514g Weight 460g Fan speed 0.78m3/min(max.) Fan speed 0.78m3/min(max.) Noise level HI 58.5dBA/LO 39.5dBA Noise level HI 58.5dBA/LO 39.5dBA Ozone production 0.05ppm or less(measured 50mm) Ozone production 0.05ppm or less(measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Accessories AC adapter AD24-ITF6-E, AC cable(1.8m) Accessories AC adapter AD24-ITF6-E, AC cable(1.8m) Decay area 150 300 300 450 600 Decay area 150 F-6 300 450 600 150 0 2sec 3sec 4sec 6sec F-6 150 0 2sec 3sec 4sec 6sec 150 300 Accessories 150 300 300 (mm) AC Adapter AD24-ITF6-E EDP No. 806096 Accessories I / P : AC100V~240V 0.4A O/P : DC24V 0.75A (mm) AC Adapter AD24-ITF6-E I / P : AC100V~240V 0.4A O/P : DC24V 0.75A EDP No. 806096 06 Applications ( F120-E ) Fan-type Ionizer with Integrated Sensor Ion balance is monitored by a sensor and adjusted automatically SFQ9-E 129 69 205 80 141 EDP No. 621626 High VoltageTransformer Ion balance Decay time Dual piezoelectric high-frequency AC corona discharge within ±5 V 1.2 sec or less Power supply DC24V Fan Speed HI/MD/LO INCLUDED TRANSFOMER LED illumination 100-240VAC Electrode needle unit replacement ALARM FAN LOCKUP Directive ALARM H.V. External grounding terminal Our original feedback sensor controls the ion balance to within ± 5V. Dual piezoelectric transformers and high-speed fan provide double the neutralization speed. Indicator shows the maintenance timing and fluctuations in ion balance. Ion blance indicator Dual piezo Interior LED light Specifications Model No. SFQ9-E Ionizing method/Applied voltage Piezoelectric high-frequency DC corona discharge/DC±4 to ±8kV Power supply and current consumption DC24V±5%/340mA(typ.) Ion balance within ±5 V Decay time 1.2 sec or less Operating range 150 mm to 900 mm H×W×Dmm H205×W141×D80mm(stand included) Weight 966g Fan speed 1.8m3/min (max.) Noise level HI 49.6dBA/LO 38.8dBA Ozone production 0.05ppm or less(measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Accessories AC adapter AD24-IT-EX AC cable(1.8m) Decay area 150 150 SF-9 0 300 450 0.5sec 1sec 2sec 150 Accessories 3sec 750 900 4sec (mm) AC Adapter AD24-IT-EX EDP No. 806050 07 600 I / P : AC100V~240V 0.4A O/P : DC24V 0.75A Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Fan-type Ionizer Fan-type Ionizer Butterfly Louver ! for wider and far reach static erasing area Silent fan model with mild airflow F120-E NEW F120S-E NEW 69.5 69.5 198 198 68 68 162 162 EDP No. 621642 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 1.3 sec or less (F-120) 2.5 sec or less ( F-120S) Power supply Fan Speed HI/MD/LO DC24V INCLUDED TRANSFOMER LED illumination 100-240VAC Electrode needle unit replacement Directive ALARM FAN LOCKUP ALARM H.V. External grounding terminal Butterfly Louver. Press outer side to desperse air. Press center to let air out straight. Apparent operation status indication. The new alarm function uses a 2-color LED. The red light indicates various errors. Easy maintenance.The electrode needle unit is set into the front cover. Butterfly Louver Options RUN lamp LED EDP No. 621646 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 1.3 sec or less (F-120) 2.5 sec or less ( F-120S) Power supply Fan Speed HI/MD/LO DC24V LED illumination INCLUDED TRANSFOMER 100-240VAC Electrode needle unit replacement Directive ALARM FAN LOCKUP External grounding terminal ALARM H.V. Butterfly Louver. Press outer side to desperse air. Press center to let air out straight. Apprent operation status indication. The new alarm function uses a 2-color LED. The red light indicates various errors. Easy maintenance.The electrode needle unit is set into the front cover. Electrode Needle Unit Butterfly Louver RUN lamp LED Electrode Needle Unit Specifications Specifications Model No. F120-E Model No. F120S-E Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 10kV(p-p) Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 10kV(p-p) Power supply and current consumption DC24V±5%/700mA(max.) Power supply and current consumption DC24V±5%/700mA(max.) Ion balance within ±10 V Ion balance within ±10 V Decay time 1.3 sec or less Decay time 2.5 sec or less Operating range 150 mm to 900 mm Operating range 150 mm to 900 mm H×W×Dmm H198×W162×D70mm H×W×Dmm H198×W162×D69.5mm Weight 0.9kg Weight 0.9kg Fan speed 3.66m3/min (max.) Fan speed 2.21m3/min (max.) Noise level HI 62.1dBA Noise level HI 50.7dBA Ozone production 0.05ppm or less(measured 50mm) Ozone production 0.05ppm or less(measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Accessories AC adapter AD24-IT-EX AC cable(1.8m) Accessories AC adapter AD24-IT-EX AC cable(1.8m) Decay area Decay area Straight (F120-E) 150 300 300 Wide (F120-E) 450 600 750 900 150 300 Straight (F120S-E) 300 450 600 750 300 150 300 Wide (F120S-E) 450 600 750 3sec 4sec 900 300 150 300 450 600 3sec 1.5sec F-120 0 1sec 300 Accessories 1.5sec 2sec 3sec F-120 (mm) 300 AC Adapter AD24-IT-EX EDP No. 806050 0 2sec 1sec F-120S (mm) 1.5sec 300 Accessories I / P : AC100V~240V 0.4A O/P : DC24V 0.75A 2sec F-120S (mm) 300 AC Adapter AD24-IT-EX 1.5sec 2sec 3sec 4sec (mm) I / P : AC100V~240V 0.4A O/P : DC24V 0.75A EDP No. 806050 08 Wide-type Ionizer with Cross-flow Fan Overhead Triple-fan Ionizer Compact, low-profile design saves space Erases static electricity over a large area by installing above your work bench or conveyor belt CF-30-E 3F-12-E 300 130 900 87 125 182 100 80 210 EDP No. 621375 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±5 V 1.4 sec or less Power supply DC24V No-step airflow volume changeover LED illumination Electrode needle unit replacement INCLUDED TRANSFOMER 100-240VAC Directive ALARM FAN LOCKUP ALARM H.V. External grounding terminal Maintains an ion balance of ±5 V using capacitive-coupled electrode needles. LED indicator lights up progressively to indicate airflow. LEDs all flash after 200 hours of operation to indicate cleaning time. EDP No. 621378 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±5 V 1.8 sec or less Power supply DC24V No-step airflow volume changeover LED illumination Electrode needle unit replacement INCLUDED TRANSFOMER 100-240VAC ALARM FAN LOCKUP External grounding terminal ALARM H.V. Disk-shaped capacity coupled electrode realizes ± 5V ion balance. Equipped with 24 VDC service power (300 mA). Error signal output terminal provided to facilitate assembly into systems. Unit Rear Side ①②③④⑤ DC24V 300mA max. Warning Drive Circuit FAN ALARM Warning Drive Circuit H.V. ALARM LOAD (MAX 50mA) LOAD (MAX 50mA) High-efficiency cross-flow fan built in LED display and airflow volume adjustment knob Capacitive-coupled electrode needles Specifications Electrode Needle Plate Alarm Output Connection Specifications Model No. CF-30-E Model No. 3F-12-E Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC p-p9kV( ) Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 2.4kV Power supply and current consumption DC24V±5%/ 650mA(max.) Power supply and current consumption DC24V±5%/1200mA(max.) Ion balance within ±5 V Ion balance within ±5 V Decay time 1.4 sec or less Decay time 1.8 sec or less Operating range 150 mm to 900 mm Operating range 150 mm to 900 mm H×W×Dmm H125×W310×D130mm H×W×Dmm H182×W913×D100mm(stand included) Weight 2.1㎏ Weight 5.3 ㎏ Fan speed 1.58m3/min(max.) Fan speed 3.4m3/min(max.) Noise level HI 51.2dBA/LO 42.5dBA Noise level HI 54.9dBA/LO 45.3dBA Ozone production 0.05ppm or less(measured 50mm) Ozone production 0.05ppm or less(measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Accessories AC adapter AD24-ITCF-EX AC cable(1.8m) Accessories AC adapter AD24-IT19 AC cable(1.8m) Decay area Decay area 150 150 300 450 600 750 900 150 450 300 450 600 750 900 1050 1200 6sec CF-30 0 2sec 3sec 150 Accessories 5sec (mm) AC Adapter AD24-ITCF-EX EDP No. 806074 09 4sec 3F-12 0 3sec 450 Accessories I / P : AC100V~240V 1.2A O/P : DC24V 1.5A 2sec 4sec 6sec (mm) AC Adapter AD24-IT19 EDP No. 806080 I / P : AC100V~240V 1.2A O/P : DC24V 1.9A Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Options VESSEL ionizers for a variety of applications. Inspection process Dust prevention on molded parts Static electricity removal in a bottle Dust and/or static electricity removal from large resin parts Film unwinding and winding Glass substrate transfer Transforming an assembly desk into a simplified clean booth Static electricity removal from films and/or products 10 Why is VESSEL’s nozzle type our customer’s top choice? 1 LED indicators clearly indicate the operating status The bright LED lamps show the operating state even when installing in dark systems. Nozzle Type N-1 NEW Ultra-compact slim body Rotary nozzle increases installation choices 2 Diverse lineup of optional nozzles support various applications Use the optional shower nozzle or silent nozzle. Decay time 0.7 sec or less N-2 Operation status displayed on LED lamps Interchangeable nozzle increases suitable applications Decay time 0.7 sec or less 3 Daisy-chain the power cables to keep high-voltage cables inside and ensure safety Power can be supplied to multiple units by daisy-chaining them. 24 VDC wiring enhances safe connection. 11 Nozzle Type Fan Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Options Super Slim Nozzle-Type Ionizer Pinpoint Nozzle Ionizer Super Compact Slim Body. A rotating nozzle enables to ionize anywhere Featuring an LED indicator that communicates the device’s operating status at a glance N-1 NEW N-2 27.5 27.5 28 109.6 28 45 107.3 95 Standard Nozzle (Straight) 45 Replaceable Nozzle Corner Nozzle (Elbow) EDP No. 621639 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 0.7 sec or less Power supply DC24V Power supply: AIR/N2 max 0.6MPa LED illumination AC Adapter (Option) Screw-type needle electrode Directive “ON” lamp ALARM H.V. External grounding terminal Super slim and compact design enabling to be installed at any place for any direction. 27.5mm×28mm. Change the blow direction by turning the rotary corner nozzle. EDP No. 621615 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 0.7 sec or less Power supply DC24V Power supply: AIR/N2 max 0.6MPa LED illumination AC Adapter (Option) Screw-type needle electrode Directive External grounding terminal ALARM H.V. “ON” lamp Easy to wire with connector terminals. Diverse nozzles support various applications. The nozzle position clicks at 90° intervals (w/corner nozzle) Alarm outputs and daisy chains possible. Specifications Standard Nozzle (included as accessory) Flared Nozzle can be angled appropriately (included as accessory) Tube-fitting Nozzle provides connection with air tube. (included as accessory) Alarm outputs and daisy chains. Specifications Model No. N-1 Model No. N-2 Ionizing method/Applied voltage Piezo high-frequency AC Corona discharge method/AC10kV(p-p) Ionizing method/Applied voltage Piezo high-frequency AC Corona discharge method/AC6kV(p-p) Power supply and current consumption DC24V±5%/58mA(typ.) Power supply and current consumption DC24V±5%/100mA(typ.) Ion balance within ±10V (standard nozzle・0.3MPa、150mm)〔measured values〕 Ion balance within ±10V (standard nozzle・0.3MPa、150mm)〔measured values〕 Decay time 0.7 sec or less (standard nozzle・0.3MPa、150mm)〔measured values〕 Decay time 0.7 sec or less (standard nozzle・0.3MPa、150mm)〔measured values〕 Operating range 50 mm to 600 mm Operating range 50 mm to 600 mm H×W×Dmm L109.6×W27.5×H28mm (with standard nozzle mounted) H×W×Dmm L95×W45×H45mm Weight 62 g (with standard nozzle mounted) Weight 106 g (with standard nozzle mounted) Air supply hose diameter tube fitting Φ6mm Air supply hose diameter tube fitting Φ6mm Operating fluid Clean dry air (0.1MPa to 0.3MPa). nitrogen N2 (0.1MPa to 0.3MPa) Operating fluid Clean dry air (0.1MPa to 0.6MPa). nitrogen N2 (0.1MPa to 0.6MPa) Airflow 181ℓ/min(With standard nozzle mounted at 0.3MPa) Airflow 217ℓ/min(With standard nozzle mounted at 0.3MPa) Ozone production 0.05ppm or less (measured 50mm) Noise level 92dBA(With standard nozzle mounted at 0.3MPa) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Ozone production 0.05ppm or less (measured 50mm) Accessories Standard Nozzle (included with device), Corner Nozzle Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) Accessories Standard Nozzle (included with device), Flared Nozzle (N-2FN), Tube- fitting Nozzle (N-2TN), Power supply harness Decay area Decay area Air Pressure : 0.3MPa <with Standard Nozzle installed> 50 150 Standard Nozzle 100 0.6sec 0 200 <with Corner Nozzle installed> 300 50 150 0.8sec 0.7sec 0 100 0.6sec 200 0.7sec 300 0.8sec Air Pressure : 0.3MPa <with Flare Nozzle installed> 50 150 300 150 0 450 600 2.0sec (mm) <Tube fitting Nozzle installed> (mm) 150 (mm) 0.5sec 1.0sec 150 (mm) 0 1.5sec 2.0sec 0 2.5sec (mm) 1.0秒 1.5sec 2.0sec 150 Accessories Standard Nozzle Corner Nozzle N-1SN N-1CN EDP No. 806120 EDP No. 806121 1.5sec 150 150 Accessories 600 <Tube fitting Nozzle and Shower Tube installed> (Tube 300mm long installed) 150 150 0 1.0sec 1.5sec 150 Corner Nozzle <with Standard Nozzle installed> 50 150 300 450 150 Flared Nozzle Tube-fitting Nozzle N-2FN N-2TN EDP No. 806086 EDP No. 806085 (mm) Electrode Needle Replacement Screwdriver (separately sold) G-7DR EDP No. 806061 12 Why is VESSEL’s gun type our customer’s top choice? 1 The bright white LED lamp makes dust visible Use the LED lamp to check dust that has adhered on the workpiece. Gun Type 2 G7R-E Compact and lightweight High discharge air blow ionizer Decay time 0.5 sec or less Piezoelectric transformer enhances safety with no need to expose high-voltage cables The high-voltage cable is not exposed, so there’s no need to worry about current leaks or electric shock caused by wire breakage. BBZ-E Eliminate dust and static electricity for wide area. Silent and highly durable Decay time 0.5 sec or less 3 Ergonomically designed grip is easy to hold and adjusted to the optimum angle The nozzle direction faces the optimum direction when the grip is held, allowing work to be started right away. 13 Fan Type Gun Type Nozzle Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Options Gun-type Ionizer Gun-type Ionizer Our most popular ionizing air gun is compact, lightweight and user-friendly Silent and high durability model ideal for air blowing in wide areas G7R-E BBZ-E 36 105 132 36 150 152 EDP No. 621615 EDP No. 621621 High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 0.5 sec or less Air Pressure max 0.6MPa Power supply DC24V LED illumination Screw-type needle electrode INCLUDED TRANSFOMER 100-240VAC Directive “ON” lamp ALARM H.V. External grounding terminal Ideal for neutralization and dust elimination of precision parts at hand, for example, in cell production. Our diverse lineup of options supports various applications. Our tough 2.5 m robot cable withstands up to 150,000 bends. Attach a brush to blow out dust Operating and malfunction alarm LEDs are provided on both sides of the grip Specifications High VoltageTransformer Ion balance Decay time Piezoelectric high-frequency AC corona discharge within ±10 V 0.5 sec or less Power supply DC24V Air Pressure max 0.6MPa LED illumination INCLUDED TRANSFOMER 100-240VAC Screw-type needle electrode Directive “ON” lamp ALARM H.V. External grounding terminal Ideal for standing work such as neutralization and dust elimination of large plastic products. Silent nozzle reduces work environment noise. 5m robot cable withstands up to 150,000 bends & screw-in connector withstands vibration The long power cable (5 m) allows work in a widespread area Silent, high-discharge air nozzle reduces wind noise Long cable allows work in wide range Specifications Model No. G7R-E Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 2kV Model No. BBZ-E Power supply and current consumption DC24V±5%/74mA (max.) Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 2kV Ion balance within ±10 V (standard nozzle・measured 150mm from device at 0.3 MPa) Power supply and current consumption DC24V±5%/74mA(max.) Decay time 0.5 sec or less (standard nozzle・measured 150mm from device at 0.3 MPa) Ion balance within ±10 V (standard nozzle・measured 150mm from device at 0.3 MPa) Operating range 50 mm to 600 mm Decay time 0.5 sec or less (standard nozzle・measured 150mm from device at 0.3 MPa) H×W×Dmm L105×H150×D36mm Operating range 50 mm to 600 mm Weight 198g H×W×Dmm L132×H152×D36mm Air supply hose diameter tube fitting Φ6mm Weight 198g Operating fluid Clean dry air ( 0.1MPa to 0.6MPa) Air supply hose diameter tube fitting Φ6mm Airflow 200ℓ/min(0.3MPa) Operating fluid Clean dry air (0.1MPa to 0.6MPa) Noise level 90dBA (0.3MPa) Airflow 200ℓ/min (0.3MPa) Ozone production 0.05ppm or less(measured 50mm) Noise level 77.3dBA (0.3MPa) Ozone production 0.05ppm or less (measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing) AC adapter AD24ITC-E AC cable(1.8m)/ Standard Nozzle (included with device) Accessories Decay area 150 0 150 300 0.5sec 0.6sec 450 0.7sec 1.0sec 600 1.4sec 150 Accessories AC adapter AD24-ITB-E AC cable (1.8m) Decay area Air Pressure : 0.3MPa (with Standard Nozzle installed ) 50 Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH (with no dew condensation or freezing) (mm) Accessories 150 50 0 Air Pressure : 0.6MPa 150 0.5sec 300 0.7sec 150 G-7SN EDP No. 806057 0.9sec 600 1.1sec (mm) Accessories Nozzle Standard Nozzle 450 Tube fitting Nozzle Brush: 60 mm bristles G-7B EDP No. 806059 Electrode Needle Replacement Screwdriver G-7DR EDP No. 806061 AC Adapter BB-ZSN AD24-ITB-E EDP No. 621708 EDP No. 806076 AC Adapter AD24-ITC-E EDP No. 806067 14 Why is VESSEL’s bar type our customer’s top choice? 1 Super Fast Static Electricity Removal AC pulse method Generating alternately positive ions and negative ions from each electrode. Since ions are generated at the maximum width of each positive and negative electrode cycle, the ion volume is high and static electricity can be removed quickly. Bar Type AC pulse AC C-series NEW Compact and clean design Super-high speed ionizer within ±30V (Distance 1000mm) B-series Extensive variations from 60 cm up to 3 m Ion balance Auto Balance Mode The C series are equipped with a mode to optimally adjust the ion balance automatically according to the polarity of the charged matter. (Target distance: 50 to 100 mm) within ±30V (Distance 1000mm) If Positive Static Articles remained... SH-series 100mm Ion balance NEW Slim and high-speed ionizer High-voltage power standalone type Ion balance within ±50V (Distance 1000mm) More negative ions are generated. Air purge function With air purged toward the needle electrod tip. This not only prevents contamination at the tip of the electrode needle, but also carries the generated ions quickly to the charged object and removes static electricity. 15 Fan Type Nozzle Type Gun Type Bar Type 2 Usability Easy maintenance design One-touch needle replacement. A socket type needle can be easily replaced. *The electrode needle cannot be removed from the SH- series. Ion Parts Cleaner EPA Working Mat Clean Walker Options 3 Line-up at a glance Sizes to match various working environments Ionizing bars are available in a variety of sizes for assembly into small electronic part manufacturing systems to neutralization of large workpieces such as film and liquid crystal glass. All bar type series lineup B-Series (mm) Clean design Needle cleaning time notified The cleaning interval can be set between one and 60 days, in one-day units. When the time elapses, the needlecleaning lamp lights up and an alarm displays. *C-series 3000 B-300 2800 B-280 2600 B-260 2400 The ion current is detected. When the ion generation drops, the ION/TIP lamp turns ON and an alarm displays. *B-series B-230 B-220 2200 B-210 B-180 1800 Body contamination prevention Opposing electrodes are incorporated in the body. The induced voltage prevents particles from sticking to the outer side of the body, and limits the losses in applied voltage to improve the ion generation efficiency. *C-series C-Series C-200 2000 C-170 B-160 1600 B-150 B-140 1400 C-150 1200 The opposing electrodes are incorporated Angle adjustment 1000 800 SH-Series 600 SH-70 SH-60 B-120 C-120 B-100 B-95 B-90 C-100 C-90 B-60 SH-50 The angle can be adjusted. 400 200 SH-40 SH-30 SH-20 SH-16 0 16 AC Pulse Ionizing Clean Bar Clean & Compact. Newly designed high-precision and high-speed ionizer applying a new technology C-series NEW C-90 C-100 C-120 C-150 C-170 C-200 EDP No. 621851 EDP No. 621852 EDP No. 621853 EDP No. 621854 EDP No. 621855 EDP No. 621856 Common Specifications Directive High VoltageTransformer Ion balance Pulse AC corona discharge within ±30 V (measured 1000 mm) Model No. C-90∼C-200 Ionizing method/Applied voltage Pulse AC Corona discharge/ AC8∼12.5kV(p-p) frequency 0.1 to 50Hz (Select form ten steps) pulse ratio Positive ion 40 to 70 %, negative ion 60 to 30% Power supply and current consumption DC24V±5%/600mA (max.) Ion balance within ±30V (Distance 1000mm) Newly designed super-fast ionizing air discharge port Decay time See below Auto Balance Mode (Target distance: 50 to 100 mm) Operating range 50 to 2000mm H×W×Dmm Refer to the figure on the right Weight Refer to the figure on the right Air supply hose diameter PT1/8 Operating fluid Clean dry air or nitrogen (N2) (0. 3 MPa or less) Power supply DC 24V ±5% Air Pressure max 0.3MPa Electrode needle unit replacement LCD Display Adjustable Ion Balance Needle Cleaning Timer ALARM H.V. (1 to 60 days) External output LAN Terminal Terminals grouped on one side. Enabling a daisy-chain connection. DC24V Power Supply Module Power Supplu Cable (attached) Interface Terminal Cat 5 Cable (locally sold) Ozone production 0.05ppm or less (measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 85% RH (with no dew condensation or freezing) Accessories Remote controller / Power cable (5m) / End brackets (included with device) / Middle bracket (included with device / C-90 is excluded) *Silicon discharge needles also available. For more detail please contact us. Daisy Chain Possible Measurement conditions ・Product : C-150 ・Voltage : 10.5kV(P-06 N-06) ・Air pressure : 0.3MPa ・Temperature : 24°C±1°C ・Humidity : 40%±2%RH ・Decay time : ±1000V→±100V ・CPM : 20pF±2pF(150x150mm) Frequency: 0.1Hz -150 -100 -50 0 50 100 150 (mm) 300 -150 300 -100 -50 AD24-IT-EX 0 50 100 1sec 600 600 150 2sec 900 900 1sec 1200 left wing 1200 4sec 1500 6 sec right wing left wing (Operatable with One Bar type IONIZER only) I / P : AC100V~240V 0.4A O/P : DC24V 0.75A EDP No. 806050 AC Adapter AD24-ITCF-EX 3sec (Operatable with Two Bar type IONIZERS only) I / P : AC100V~240V 1.2A O/P : DC24V 1.5A 5sec 2 sec 3 sec 1500 Options AC Adapter Frequency: 30Hz (mm) Decay area EDP No. 806074 AC Adapter right wing AD24-ITCF-EX (Operatable with Three Bar type IONIZERS only) Frequency: 1Hz -100 -50 600 0 50 100 -150 300 -100 -50 1sec 900 5 sec left wing 17 6sec right wing 150 EDP No. 806080 RMC-01 EDP No. 806104 3 sec 4 sec 1200 4 sec 100 Remote Control 3 sec 1500 50 2 sec 2 sec 1200 0 600 1sec 900 150 (mm) -150 (mm) 300 I / P : AC100V~240V 1.2A O/P : DC24V 1.9A Frequency: 50Hz Power Supply Cable(5m) 5 sec 6 sec 1500 left wing CT-5 EDP No. 621533 right wing Fan Type Nozzle Type Gun Type Ion Parts Cleaner Bar Type EPA Working Mat Clean Walker Options 70 33 33 60 70 70 60x23=1380 800 40 65 78 1520 4-φ5x13 2-φ5x10 (785.5) 1571 877 1597 Electrode needles : 12pcs. Middle bracket : No Weight : 1.8kg 33 70 33 60 (545.5) 78 4-φ5x13 (603.7) (545.5) 1811 1117 1837 4-φ5x13 (603.7) 33 33 60 60x31=1860 70 (665.5) (683.7) 78 40 40 65 4-φ5x13 65 2-φ5x10 78 65 (665.5) 33 2000 1280 40 70 52.5 92.5 33 70 60x19=1140 52.5 60 C-200 92.5 Electrode needles : 28pcs. Middle bracket : 2 Weight : 1.6kg C-120 78 4-φ5x10 (603.7) 1091 Electrode needles : 16pcs. Middle bracket : 1 Weight : 1.0kg 40 65 78 2-φ5x10 40 65 40 65 33 1760 1040 70 70 60x27=1620 52.5 92.5 33 70 60x15=900 52.5 60 C-170 92.5 Electrode needles : 12pcs. Middle bracket : 1 Weight : 1.4kg C-100 78 4-φ5x13 (785.5) 851 70 33 52.5 33 60x11=660 52.5 60 70 C-150 92.5 C-90 92.5 (Unit:mm) 4-φ5x10 (683.7) 4-φ5x13 (683.7) 2051 1331 2077 1357 Electrode needles : 20pcs. Middle bracket : 1 Weight : 1.2kg Electrode needles : 32pcs. Middle bracket : 2 Weight : 1.8kg Frequency Voltage Level The frequency can be set in ten steps (0.1 to 50 Hz). The applied voltage can be changed individually for the positive and Film negative side. The amount of ions can be changed by different output steps. (Ten steps: 8.0 to 12.5 kVp-p) Film manufacturing Close distance: 50 to 300mm Clean room bench Medium distance: 600 to 750mm Clean room ceiling Voltage level 1 Positive voltage (kV) 4 4.25 4.5 4.75 5 Negative voltage (kV) 4 4.25 4.5 4.75 kV p-p 8 8.5 Far distance: 900 to 1500mm Pulse Ratio The ion balance can be adjusted by changing the pulse ratio. 2 3 9 4 9.5 5 6 7 9 10 5.25 5.5 5.75 6 6.25 5 5.25 5.5 5.75 6 6.25 10 10.5 12 12.5 11 8 11.5 Example of power connection Address When using multiple units, an address allocation (1 to 16) can be set to identify each device. Power cable : CT-5 Power adapter 18 AC Pulse Ionizing Bars AC pulse bar with various setting functions to support your application B-series B-60 B-90 B-95 B-100 B-120 B-140 B-150 B-160 High VoltageTransformer Ion balance Pulse AC corona discharge within ±30 V (measured 1000 mm) Air Pressure max 0.3MPa Electrode needle unit replacement LCD Display Adjustable Ion Balance Needle Cleaning Timer ALARM H.V. External output LAN Terminal Possible to eliminate electricity equally by changing the intervals between needle electrodes. The ion balance adjustmrent function enables use of the device in a variety of applications. Electrode needle units twist off for easy replacement. 3.65 3.65 3.65 Decay area 55 55 55 55 55 ※ B-260/280/300 are made-to-order items. Model No. B-60∼B-300 Ionizing method/Applied voltage Pulse AC Corona discharge/AC8∼12.5kV (p-p) frequency 0.1 to 50Hz (Select f rom ten steps) pulse ratio Positive ion 40 to 70 %, negative ion 60 to 30% Power supply and current consumption DC24V±5%/600mA (max.) Ion balance within ±30V (Distance 1000mm) Decay time See below Operating range 50 to 2000mm H×W×Dmm Refer to the figure on the right Weight Refer to the figure on the right Air supply hose diameter PT1/8 Operating fluid Clean dry air or nitrogen (N2) (0.3 MPa or less) Ozone production 0.05ppm or less (measured 50mm) Operating environment temperature and humidity 5°C to 50°C/35% to 85% RH (with no dew condensation or freezing) Accessories Remote controller / Power cable (5m) / End brackets (included with device) / Middle bracket (included with device) / B-60 to B-140 is excluded) 55mm Measurement conditions ・Product : B-100 ・Air pressure : 0.3MPa Frequency: 0.1Hz -100 Frequency: 50Hz Frequency: 0.3Hz -50 0 50 100 600 150 (mm) -150 300 EDP No. 621519 EDP No. 621520 EDP No. 621521 EDP No. 621522 EDP No. 621523 EDP No. 621524 EDP No. 621525 -150 300 -100 -50 0 50 600 100 150 -150 300 -100 -50 0 900 0-3 sec 1200 3-6 sec 1500 12-15sec 3-6sec left wing 6-9sec 1200 6-9sec 6-9 sec 12-15 sec 1500 right wing left wing 150 3-6sec 900 1200 100 0-3sec 600 0-3sec 900 50 (mm) DC 24V ±5% B-180 B-210 B-220 B-230 ※ B-260 ※ B-280 ※ B-300 Common Specifications Directive (mm) Power supply EDP No. 621511 EDP No. 621512 EDP No. 621513 EDP No. 621514 EDP No. 621515 EDP No. 621516 EDP No. 621517 EDP No. 621518 12-15sec 1500 right wing left wing right wing Options AC Adapter 19 AC Adapter AC Adapter AD24-IT-EX AD24-ITCF-EX AD24-ITCF-EX (Operatable with One Bar type IONIZER only) (Operatable with Two Bar type IONIZERS only) (Operatable with Three Bar type IONIZERS only) I / P : AC100V~240V 0.4A O/P : DC24V 0.75A I / P : AC100V~240V 1.2A O/P : DC24V 1.5A I / P : AC100V~240V 1.2A O/P : DC24V 1.9A EDP No. 806050 EDP No. 806074 EDP No. 806080 Power cable(5m) Branch Adapter Power Supply Separator EDP No. 621533 EDP No. 621531 EDP No. 621532 CT-5 B-SP2 B-SP3 Fan Type Nozzle Type Gun Type Ion Parts Cleaner Bar Type EPA Working Mat Clean Walker B-90 ∼300 B-60 Options (Unit:mm) D±2.5 660±2.5 C±2.5 = 10 = 4-φ5X9 78 40 23 23 2-φ5X9 18 30 30 18 65 4-φ5X9 640±2.5 62 480±2.5 36.5 34.4 604±2.5 109.5 68.5 A1±2.5 A±2.5 B±2.5 A' 55 109.5 36.5 6.5 40 40 40 40 40 40 40 40 40 40 40 40 62 6.5 70 33 109.5 33 70 109.5 A 34.4 68.5 45° 90° SECTION A-A' Dimension/Electrode needles/Middle Blacket Model No. A (mm) A1 (mm) B (mm) C (mm) D (mm) Electrode needles Middle Blacket Weight (kg) B-60 480 ー 604 640 660 13pcs. 0 1.2 B-90 769 550 906 942 962 17pcs. 0 1.5 B-95 824 605 961 997 1017 18pcs. 0 1.6 B-100 934 715 1071 1107 1127 20pcs. 0 1.6 B-120 1099 880 1236 1272 1292 23pcs. 0 1.8 B-140 1264 1045 1401 1437 1457 26pcs. 0 2.0 B-150 1374 1155 1511 1547 1567 28pcs. 1 2.1 B-160 1484 1265 1621 1657 1677 30pcs. 1 2.2 B-180 1704 1485 1841 1877 1897 34pcs. 1 2.3 B-210 2034 1815 2171 2207 2227 40pcs. 2 2.6 B-220 2144 1925 2281 2317 2337 42pcs. 2 2.7 B-230 2254 2035 2391 2427 2447 44pcs. 2 2.8 B-260 2474 2255 2611 2647 2667 48pcs. 3 3.1 B-280 2694 2475 2831 2867 2887 52pcs. 3 3.3 B-300 2914 2695 3051 3087 3107 56pcs. 3 3.5 Wiring example When connecting 1 pulse ion bar Using the included power supply cable Included power supply cable Using a CT-5 power supply cable and AD24-IT-EX AC Adapter Power cable:CT-5 or AC Adapter:AD24-IT When connecting 2 pulse ion bars Using a B-SP2 branch adapter, CT-5 power supply cable, and AD24-ITCF-EX AC Adapter Branch adapter :B-SP2 Power cable:CT-5 AC Adapter:AD24-ITCF *LAN cable (commercially available cable) Ask for a CAT5 LAN cable. When connecting 3 pulse ion bars Using a B-SP3 power supply separator, CT-5 power supply cable, and AD24-IT19 power supply transformer Cable length: Max. 20 m to end of bar Power supply separator :B-SP3 *You can also use a switching power supply and no AC Adapter ( 24 VDC, max. 10 A ). *LAN cable (commercially available cable) Ask for a CAT5 LAN cable. Power cable:CT-5 AC Adapter:AD24-IT19 20 Compact AC Pulse Ionizing Bars (separate power supply type) Slim & High-speed Neutralization. Compact bar type ionizer with separate power supply for easy installation. SH-series NEW SH-16 SH-20 SH-30 SH-40 SH-50 SH-60 SH-70 EDP No. 621541 EDP No. 621542 EDP No. 621543 EDP No. 621544 EDP No. 621545 EDP No. 621546 EDP No. 621547 Directive High VoltageTransformer Ion balance Pulse AC corona discharge within ±50 V (measured 1000 mm) Power supply DC 24V ±5% Air Pressure max 0.3MPa Positive and negative ion Electrode needle unit replacement Adjustable Ion Balance Needle Cleaning Timer ALARM H.V. External output LAN Terminal Air purging functions. Safe Design. Flexible silicone sheath cable. Up to three bars can be branched and wired using the branch box (SH-SP2). Common Specifications Silicone sheath cable Flexible silicone sheath cable adopted Decay area 0 50 0-2sec 600 100 150 (mm) -50 Pulse AC Corona discharge/AC10.5kV (p-p) frequency 30Hz pulse ratio Positive ion 40 to 70 %, negative ion 60 to 30% Power supply and current consumption AC100V∼AC240V/10W (SH-G3) Ion balance within ±50V (Distance 1000mm) Decay time See below Operating range 50 to 2000mm H×W×Dmm Refer to the figure on the right Weight Refer to the figure on the right Air supply hose diameter tube fitting Φ6mm Operating fluid Clean dry air or nitrogen (N2) (0.5 MPa or less) Ozone production 0.05ppm or less Operating environment temperature and humidity 5°C to 55°C/25% to 85% RH (with no dew condensation or freezing) Accessories High-voltage cable 2.3m (included with device) Wiring example Connecting 1 or 3 pulse ionizing bars to the power supply unit Frequency: 30Hz -100 SH-16∼SH-70 Ionizing method/Applied voltage Air purging functions Measurement conditions ・Product : SH-50 ・Air pressure : 0.3MPa -150 300 Model No. Using an SH-SP2 branch box and SH-EC3 relay cable 2.3m SH-SP2 2.3m A SH-G3 SH-EC3 (3m) 2.3m 900 B 2-4sec 1200 Using an SH-SP2 branch box and SH-EC5 relay cable 4-6sec 1500 2.3m left wing A SH-SP2 SH-G3 SH-EC5 (5m) right wing 2.3m Options B Power cable:CT-5 Using an SH-SP2 branch box and SH-EC3 relay cable SH-EC5 (5m) branch box Relay Cable(3m) Relay Cable(5m) EDP No. 621552 EDP No. 621553 EDP No. 621554 SH-SP2 21 SH-EC3 SH-EC5 SH-SP2 A SH-G3 SH-EC5 (5m) *Power supply cable (relay cable) length cannot exceed a total of 10 m to the two high-voltage sockets (A, B). *Up to three SH bars can be connected from a single power supply unit ( SH-G3 ). Fan Type Gun Type Bar Type SH-40 Electrode needles : 8pcs. Weight : 0.36kg 30 27 6.7 405 1.5 16 2 33 30 373 16 2 30 148 1.5 19 409 180 2.3m 2.3m SH-50 Electrode needles : 13pcs. Weight : 0.57kg 548 Electrode needles : 10pcs. Weight : 0.40kg 60 19 530 6.7 52.5 19 420 P35 27 258 135 32.5 30 23 36.4 9 P15 30 33 60 315 P35 184 9 Options (Unit:mm) 23 36.4 27 30 23 200 6.7 36.4 9 P15 SH-20 Clean Walker 443 47.5 19 105 27.5 EPA Working Mat Electrode needles : 10pcs. Weight : 0.50kg 218 9 Ion Parts Cleaner 30 SH-16 Nozzle Type 1.5 30 27 23 510 33 184 2 1.5 180 148 16 2 30 33 16 478 30 200 6.7 36.4 514 SH-60 2.3m Electrode needles : 16pcs. Weight : 0.63kg 653 60 210 27 619 19 615 33 30 23 27 1.5 P35 6.7 36.4 9 19 23 36.4 338 30 60 P35 6.7 Electrode needles : 7pcs. Weight : 0.42kg 525 30 16 583 2 30 SH-30 9 30 2.3m 320 304 2.3m 16 2 SH-70 Electrode needles : 19pcs. Weight : 0.70kg 758 30 60 630 19 27 740 6.7 36.4 2.3m P35 23 9 30 268 30 33 1.5 300 724 90° 1.5 720 33 2 30 38.5 16 688 2 18 30 2.3m Power supply units Power supply units supporting 100 to 240 VAC SH-G3 200 138 100 80 15 R3 (mm) 61.2 218 1.5 230 Directive EDP No. 621555 Specifications Model No. SH-G3 H×W×Dmm L230×W138×H62.7mm Power supply and current consumption AC100V∼AC240V/10W (SH-G3) Weight 1.5kg Accessories AC power cable 1.8m (for 100 VAC and 240 VAC input) 2 cables AC power cable For AC100V For AC200V 1.8m 1.8m 22 Why is VESSEL’s ion parts cleaner our customer’s top choice? 1 Ion Parts Cleaner IPC-A4 Ideal A4 size for cell workbenches IPC-A3 NEW Ideal A3 size for cell workbenches Neutralization and dust elimination inside hoods Dust adhered with static electricity is neutralized inside the ionized hood and eliminated with automatic powerful air blow. 2 Forcibly collecting blown dust with dust collector Maintain a clean environment by using air blow to remove foreign matter from pre-assembly parts, and prevent dust from scattering around the area. IPC20-E Integrated ionizer and dust collector IPC40-E Separated hood and dust collector IPC-60 600mm wide hood for large workpieces 23 3 Capture dust with self-adhesive urethane gel The urethane gel’s adhesive surface catches any dust blown away by the ionized air blow. The washable gel sheet can be used repeatedly. Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Options Ion Parts Cleaner Ion Parts Cleaner A4 size is ideal for capturing dust with adhesive urethane gel at cell workbench A3 size is ideal for capturing dust with adhesive urethane gel at cell workbench IPC-A4 IPC-A3 420 NEW 314 323 190 225 150 210 361 411 253 300 Eco-friendry product Eco-friendry product EDP No. 621610 EDP No. 621612 Sensor Air blow Off delay timer Diffused reflection type Continuous/ pulse blow selection 1 to 30 seconds Power supply DC24V Air Pressure max 0.5MPa Ionizer N-1×1pcs Pinpoint L-shape corner nozzle×1pcs Directive (5 steps) AC adapter 100 to 240V Regulator Built-in Self-adhesive polyurethane gel sheets and non-woven fabric filter Integrated hood/dust collector With no built-in dust collector, its power consumption is substantially reduced. Dislodged dust will be collected by the adhesive gel sheets. Select continuous or pulse blow of ionizing dust collection air from nozzle-type ionizer Off Time Set Sensor Air blow Off delay timer Diffused reflection type Continuous/ pulse blow selection 1 to 30 seconds Power supply DC24V Air Pressure max 0.7MPa Ionizer N-1×2pcs Pinpoint L-shape corner nozzle×2pcs Directive (5 steps) Regulator Built-in AC adapter 100 to 240V Self-adhesive polyurethane gel sheets and paper pack filter Integrated hood/dust collector With no built-in dust collector, its power consumption is substantially reduced. Dislodged dust will be collected by the adhesive gel sheets. A paper pack filter can be attached to the exhaust port on the rear side (standard). Pulse Set Self Adhesive GEL collects Dust Regulator Built-in Specifications Filter to Duct Relaceable Specifications Model No. IPC-A4 Model No. IPCIPC-A3 Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 6kV Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 6kV Power supply DC24V±5% Power supply DC24V±5% Current consumption 700mA or less Current consumption 900mA or less Dust collection airflow 3.5 m3 /min (Built-in fan) Dust collection airflow 1.13 m3 /min (Built-in fan) Static pressure 105Pa (Built-in fan) Static pressure 460Pa (Built-in fan) Dust collection filter Self-adhesive polyurethane gel sheets and non-woven fabric filter Dust collection filter Self-adhesive polyurethane gel sheets and paper pack filter H×W×Dmm H361×W314×D253mm H×W×Dmm H411×W420×D300mm Weight 6kg Weight 9.5kg Air supply hose diameter tube fitting 8mm Air supply hose diameter tube fitting Φ8mm Operating fluid Clean dry air (0.1MPa to 0.5MPa) Operating fluid Clean dry air (0.1MPa to 0.7MPa) Airflow 150ℓ/min (0.3MPa) Airflow 190ℓ/min (0.3MPa) Ozone production 0.05ppm or less (measured 50mm) Ozone production 0.05ppm or less (measured 50mm) Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH (with no dew condensation or freezing) Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing) Accessories AC adapter AD24-IT19-EX Pinpoint L-shape corner nozzle×1pc Adhesive gel sheet plate (included with device)×2pcs Accessories AC adapter AD24-IT19-EX Pinpoint L-shape corner nozzle×1pc Adhesive gel sheet plate (included with device)×2pcs Duct flenge (for φ75mm) Paper pack filter (6pc.) Replacement parts Replacement parts Adhesive gel sheet (1pc) Electrode needle (1pc) Adhesive gel sheet (1pc) Electrode needle (1pc) Paper pack filter (6pc.) IPC-A4G N-1H IPC-A4G N-1H IPC-A3F EDP No. 806091 EDP No. 806122 EDP No. 806091 EDP No. 806122 24 Ion Parts Cleaner Ion Parts Cleaner Compact, integrated design is ideal for use in a cell production setting or confined space Separate type features a dust collector and standalone hood to make effective use of limited space IPC20-E IPC40-E 518 385 450 220 402 345 150 462 678 481 358 326 386 354 EDP No. 621379 Sensor Air blow Off delay timer Diffused reflection type Continuous 3sec ( 0.1 to 5 sec ) Power supply AC100V Air Pressure max 0.7MPa Ionizer F-6×1pc Air Nozzle 2pcs AC adapter EDP No. 621380 Directive Thermal protector Mediumefficiency filter Integrated hood/dust collector Sensor Air blow Off delay timer Retroreflective Continuous 3sec ( 0.1 to 5 sec ) Power supply AC100V Air Pressure max 0.7MPa Ionizer F-6×1pc Air Nozzle 2pcs AC adapter Thermal protector Directive Mediumefficiency filter Separate hood/dust collector Workpiece is detected with sensor, and dust eliminating air is sprayed. Flexible nozzle enables pinpoint dust removal from workplaces. Cylindrical cartridge type medium-efficiency filter incorporated. Cylindrical cartridge type medium-efficiency filter incorporated. Compact fan ionizer is ideal for spaces with no static inside the hood. Compact fan ionizer is ideal for spaces with no static inside the hood. Drum Filter Cartridge Specifications Specifications Model No. IPC20-E Model No. IPC40-E Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 3.5kV Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 3.5kV Power supply AC230V (50/60Hz) Power supply AC230V (50/60Hz) Current consumption 0.42A (50Hz)/0.4A (60Hz) Current consumption 1.2A (50Hz)/1.4A (60Hz) Dust collection airflow 1.6 m3 /min (50Hz)/2.0 m3 /min (60Hz) Dust collection airflow 3.3 m3 /min (50Hz)/4.0 m3 /min (60Hz) Static pressure 0.35kPa (50Hz)/0.50kPa (60Hz) Static pressure 0.88kPa (50Hz)/1.23kPa (60Hz) Table surface controlled air speed 0.8 m/sec (50Hz)/1.0 m/sec (60Hz) Table surface controlled air speed 0.4 m/sec (50Hz)/0.5 m/sec (60Hz) Dust collection volume 0.5 L Dust collection volume 1.2L Dust collector output 50W Dust collector output 200 W Dust collection filter Medium-efficiency filter (Cylindrical cartridge filter) Dust collection filter Medium-efficiency filter (Cylindrical cartridge filter) H×W×Dmm H682×W358×D385mm H×W×Dmm Hood:H400×W518×D462mm/dust collector:H416×W481×D354mm Weight 21kg Weight Hood:12kg/dust collector:30kg Air supply hose diameter tube fitting Φ6mm Air supply hose diameter tube fitting Φ6mm Operating fluid Clean dry air (0.4MPa to 0.7MPa) Operating fluid Clean dry air (0.4MPa to 0.7MPa) Airflow 355ℓ/min (0.7MPa) Airflow 355ℓ/min (0.7MPa) Noise level 56dBA (50Hz)/58dBA (60Hz) Noise level 62dBA (50Hz)/65dBA (60Hz) Ozone production 0.05ppm or less (measured 50mm) Ozone production 0.05ppm or less (measured 50mm) Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing) Accessories 25 Plastic adjusting screwdriver for sensor, hazardous use prohibited display sheet Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing) Accessories Plastic adjusting screwdriver for sensor, hazardous use prohibited display sheet Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Options Ion Parts Cleaner Featuring a wide 600 mm hood capable of accommodating large work IPC-60 668 600 220 402 462 481 326 386 354 *Same Dust Collector as IPC 40-E EDP No. 621607 Sensor Air blow Off delay timer Retroreflective Continuous 3sec ( 0.1 to 5 sec ) Power supply AC100V Air Pressure max 0.7MPa Ionizer F-6×1pc Air Nozzle 2pcs AC adapter Thermal protector Directive Mediumefficiency filter Separate hood/dust collector Flexible nozzle enables pinpoint dust removal from workplaces. Cylindrical cartridge type medium-efficiency filter incorporated. Compact fan ionizer is ideal for spaces with no static inside the hood. Specifications Model No. IPC-60 Ionizing method/Applied voltage Piezoelectric high-frequency AC corona discharge/AC 3.5kV Power supply AC100V±5% (50/60Hz) Current consumption 3.0A (50Hz)/3.0A (60Hz) Dust collection airflow 3.3 m3 /min (50Hz)/4.0 m3 /min (60Hz) Static pressure 0.88kPa (50Hz)/1.23kPa (60Hz) Table surface controlled air speed 0.4 m/sec (50Hz)/ 0.5 m/sec (60Hz) Dust collection volume 1.2L Dust collector output 200 W Dust collection filter Medium-efficiency filter (Cylindrical cartridge filter) H×W×Dmm Hood:H400×W668×D462mm/dust collector:H416×W481×D354mm Weight Hood:147kg/dust collector:30kg Air supply hose diameter tube fitting Φ6mm Operating fluid Clean dry air (0.4MPa to 0.7MPa) Airflow 355ℓ/min (0.7MPa) Noise level 62dBA (50Hz)/65dBA (60Hz) Ozone production 0.05ppm or less (measured 50mm) Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing) Accessories Plastic adjusting screwdriver for sensor, hazardous use prohibited display sheet 26 Why is VESSEL’s EPA Working Mat our customer’s top choice? 1 Creating an optimum EPA environment from work surface, floor to worker bodies with a one-stop solution Our IEC61340-5-1 compliant products include ESD protection items, workbenches, storage shelves, EPA working mats for dolly surfaces, EPA flooring for vinyl floors and painted floors, and anti-ESD wrist straps. EPA Working Mat Mat 2 Ideal for workbenches needing static-erasing measures Steady conductivity performance Conductivity rates fluctuate easily according to changes in the working environment’s humidity. VESSEL’s conductive rubber mats realize a “conductive performance” that complies with strict selection standards. Wrist Straps Anti-ESD wrist band [Ω] ×10 Electrostatic Field Meter Essential item for static electricity measures Visual the static charge and discharge state 27 ×10 9 8 Conductive Rubber Mat 4.5 ×10 1.7 7 Temperature 23℃ Humidity 29% Temperature 25℃ Humidity 51% Fan Type Nozzle Type Gun Type Bar Type EPA Working Mat Ion Parts Cleaner Clean Walker EPA Working Mat・Conductive Rubber Mat Grounding Tap Controlling electroconductivity to 106Ω or more 107 Ω or less without influence from the working environment Ideal for workbenches requiring static electricity measures on backing Neatly wire the grounding cords around your workbench Options EPS-GT2 EPS-GT2 EPG-01 EDP No. 621402 Specifications Model No. EPS-GT2 Size Approx. 3.0 m (with round jack) Resistance value 1MΩ Material ABS Mat-connecting gel 10 m LG-100 ROLL Made from medical-grade conductive gel, with no need for time-consuming eyelet setting EDP No. 621464 EDP No. 621461 SG-100 Applications Conductivity Material Designed for use with work benches 10 6≦R≦10 7Ω NBR+SBR EPG-01/EPG-02 Directive EPA Offers uniform, consistent conductive performance. Features a matte surface finish, reducing reflections and helping prevent eye fatigue prevention. Heat resistant to dropping solder. EPG-01 Mat-connecting gel with hook (set of 2) Mat-connecting gel (set of 2) fixing a snap punching EPG-02 No need for holing or crimping EPG-01 EPG-02 Common Specifications Model No. EDP No. 621481 EDP No. 621482 EPG-02 EPG-01 50×50mm Size 104Ω or less Conductivity Operating environment temperature and humidity 5°C to 30°C / 60% RH or less Conductive polyurethane, SUS, carbon film, PET Material Conductive polyurethane, carbon film, PET Grounding Cord Connect to mat-connecting gel with a single touch Structure Surface layer (static electricity-diffusing rubber) EPC-18/EPC-30 Backing (conductive rubber) Common Specifications LG-100 SG-100 Light green Green Size W1.0m×L10m×t2.0mm W1.0m×L10m×t2.0mm Conductivity 10 6≦R≦10 7Ω 10 6≦R≦10 7Ω Weight 31kg/roll 31kg/roll Material NBR+SBR NBR+SBR Model No. Color EPC-30 EPC-18 EPC-30 Common Specifications Model No. Size Resistance value Accessories EDP No. 621393 EDP No. 631394 EPC-18 EPG-02 max. length of 1.8m (max. length 0.5m) max. length of 3.0m (max. length 1.5m) 1M Ω Alligator clip 28 Ground Sensor ( Metal Band ) Grounding Sensor Warns the operator with light and sound when a grounding problem is detected Designed to minimize dust generation, this ground sensor can be used in clean rooms. EPS-01EU/EPS-01G EPS-03S/EPS-03M 45 18 46 80 (100) EPS-03S:132, EPS-03M:167 28 *EPS-03S/EPS-03M ships with band and sensor connected. EPS-01EU EDP No. 621406 EPS-01G EDP No. 621407 Applications Resistance value EPS-01EU : 2 MΩ EPS-01G : Directive For use in ESD protected areas and by device operators EPA For use in general work environments and by device operators ANTI-METAL ALLERGY SUS316L ALARM BAD GROUND Washable Battery Charge Alarm The strap warns the operator with light and sound when a grounding problem occurs. A LOW BATTERY LED lights up when the remaining battery charge falls to 20% or below. A sensitivity adjustment knob lets you fine-tune the detection range. Applications Resistance value For use in clean rooms, general work environments, and by device operators 2 MΩ ALARM BAD GROUND Washable Battery Charge Alarm Directive EPA Low dust Common Specifications EPS-01 Size Model No. EPS-01G Size Strap length Approx. 180 mm Resistance value EPS-03S EPS-03M Strap length Approx. 132 mm Strap length Approx. 167 mm Resistance value Body 1 MΩ/Grounding cord 1 MΩ Material Body 1 MΩ/Grounding cord 1 MΩ Material ABS, SUS Accessories EDP No. 621399 EDP No. 621398 The strap warns the operator with light and sound when a grounding problem occurs. A LOW BATTERY LED lights up when the remaining battery charge falls to 20% or below. A sensitivity adjustment knob lets you fine-tune the detection status. Common Specifications Model No. EPS-03S EPS-03M ANTI-METAL ALLERGY SUS316L Low dust 4.5 18 45 ABS, SUS Accessories Grounding cord 1.8m, Alligator clip, Test battery (already installed in CR1220) Grounding cord 1.8m, Alligator clip Anti-ESD Wrist Strap Metal Band Fits the wrist comfortably and can be washed for repeated use Complies with IEC 61340-5-1 for peace of mind EPS-04B/EPS-04EU EPS-02S/EPS-02M 20 sets Economy pack Ultra Sonic Cleaner (Available on the market) No.EPS-02S:130 No.EPS-02M:160 EPS-02S EPS-02M Applications Resistance value Ideal for use in clean rooms and in IT-related manufacturing 1 MΩ ANTI-METAL ALLERGY SUS316L Washable 37 Directive Common Specifications Size Resistance value Material Accessories 29 EDP No. 621403 EDP No. 621401 Applications Resistance value For use in general work environments; ideal for use in IT-related manufacturing settings with numerous temporary employees. 1 MΩ ANTI-METAL ALLERGY SUS316L Low dust Stretchable band is easy to put on and take off. Available in two sizes (small/medium). Can be easily cleaned using an ultrasonic cleaner, (available on the market) ensuring that the band is always clean and ready for use. Model No. EPS-04B EPS-04EU EDP No. 621409 EDP No. 621408 EPA 200 26 16 20 42 20.5 Washable Directive EPA (EPS-04EU) Low dust Adjustable strap fits the wrist comfortably. Safety-conscious design keeps the conductive area from being exposed on the surface of the wrist strap. Also Available as Easy Pack EPS-04EU (e-Box) . Common Specifications EPS-02S EPS-02M Strap length Approx. 130 mm Strap length Approx. 160 mm Grounding cord 1 MΩ ABS, SUS Grounding cord 1.8m, Alligator clip Model No. Size Resistance value Material Accessories EPS-04B EPS-04EU (20 pcs/set) Strap length Approx. 200 mm Strap length Approx. 200 mm Grounding cord 1 MΩ PC, SUS Grounding cord 1.8m, Alligator clip Fan Type Nozzle Type Gun Type Bar Type EPA Working Mat Ion Parts Cleaner Clean Walker Options Electrostatic Field Meter Electrostatic Field Meter Compact measuring instrument for measuring ionizer’s ion balance and product’s static potential Visualizing invisible static electricity Peak hold supports long-time measurements Eye-01 Eye-02 73 NEW 115 width:25 EDP No. 621602 Measurement Measurement LCD display Charge potential Ion balance Bar graph+ 3digits One 9V battery ion balance measurement plate Measuring distance 25 mm Out of measuring range alarm Auto power off 70 Peak hold function 123 width:25 EDP No. 621603 Directive Battery level display Anti-Drop strap Measurement Measurement LCD display Charge potential Ion balance Bar graph+ 3digits ion balance measurement plate One 9V battery Measuring distance 25 mm Auto power off Out of measuring range alarm Peak hold function Directive Battery level display Easily establish measurement distance with focus ring LED. Easily establish measurement distance with cross mark LED. Backlight enhances visibility in dark places. Color LCD clearly shows the polarity. Color LCD clearly shows the polarity. Mountable onto a tripod. Focus Ring Anti-Drop strap NG 25mm OK How to read : when two images get together into one for the Scaling. (Too Far) (Too Close) Charge Direction/Electrode Scale Specifications Specifications Model No. EYE-01 Model No. EYE-02 Charge potential measurement ±0 to ±1.49 kV (LO range)/±1.0 to ±20.0 kV (HI range) Charge potential measurement ±0 to ±1.50 kV (LO range)/±1.0 to ±20.0 kV (HI range) Ion balance measurement 0 to ±200 V Ion balance measurement 0 to ±200 V Response time within 1sec Response time within 1sec Accuracy ±10% Accuracy ±10% Power One 9V battery (006P) Power One 9V battery (006P) Charged potential measurement distance 25mm±0.5mm Charged potential measurement distance 25mm±0.5mm L×W×Dmm L115×W73×D25mm L×W×Dmm L123×W70×D25mm Weight 140g/ion balance measurement plate 30g Weight 170g/ion balance measurement plate 30g Operating environment temperature and humidity 10°C to 40°C/60% RH or less Ion balance measurement plate, Grounding cord, alligator clip, Battery (006P), Soft case Accessories ◆ Complies Operating environment temperature and humidity 10°C to 50°C/80% RH or less Ion balance measurement plate, Grounding cord, alligator clip, Battery (006P), Soft case Accessories ◆ Complies with ISO 9000 traceability standards. Calibration tables and certificates can be issued for this instrument. (Option) with ISO 9000 traceability standards. Calibration tables and certificates can be issued for this instrument. (Option) Static Locator Check for static charges and test the effectiveness of ionizers. Provides a simple digital readout of static electricity SDL-01 102 Provides a digital readout of the potential of a charged object without making contact, making it easy to measure invisible static electricity. Convenient, lightweight design is extremely portable. Comes with a soft storage case. Low-power-consumption design can be used on 4 AA batteries. LCD display 3 digits 4 AA batteries 43 EDP No. 621382 Measurement Charge potential ion balance measurement plate Measuring distance 50 mm Auto power off Out of measuring range alarm Peak hold function Battery level display Drop prevention strap 51 Specifications Model No. SDL-01 Charge potential measurement 0 to ±19.9 kV (min. display increment of 0.1 kV) Ion balance measurement − Response time 0.5 sec Display range Min. display increment of 0.1 kV Supply voltage 6 VDC (4 AA batteries) Device to charged object 50mm L×W×Dmm L102×W51×D43mm Weight 170 g (including battery) Operating environment temperature and humidity 0°C to 40°C/20% to 60% Accessories 4 AA batteries, soft case 30 Why is VESSEL’s Clean Walker our customer’s top choice? 1 Non-peeling type adhesive mat ed to pee l ne ! off No There’s no need sacrifice cleanliness by limiting the number of sheets peeled to save costs. Clean Walker 2 Reliably catching dust CW-900B 5mm thick Capture dust off shoe soles CW-900EZ Self-adhesiveness of polyurethane resin is the key.The thick mat flexibly contacts against shoe treads and carefully catches dust between them. NEW 3mm thick Strong and tear resistant even under heavy objects Clean Walker CW-T900 NEW Inclined for easy trolley access Conventional peel-off mats 3 Wash & dry to restore adhesiveness Wet the surface with water, alcohol or diluted household detergent, and the dirt will lift right up. Wash and dry the mat well to restore the original adhesiveness. 31 Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Clean Waker Eazy High elasticity. Outstanding dust collection performance Easy maintenance. Just 3mm thickness Applications Material For indoor use Polyurethane (especially in front of clean rooms) CW-900EZ ed to pee l ne ! off CW-900B No Clean Waker Options NEW Eco-friendry product Eco-friendry product EDP No. 621485 EDP No. 621486 Washable Applications Material For indoor use Polyurethane, non-woven textiles Directive (especially in front of clean rooms) Washable Directive Non-woven textiles are sandwiched with a 3mm thickness to attain a high strength Resist tears even under the pressure of trolleys. Take the mat out of the floor and wash it with water.Hang from hook holes to dry off. The 5mm high elasticity mat. Powerfully catches dust from shoe soles. Collected dust can be easily wiped off with a wet cloth. Specifications Specifications Model No. CW-900B Model No. CW-900EZ Color Blue Color Light purple Size W900mm×L500mm×t5mm Size W450mm×L500mm×t3mm Conductivity Insulator Conductivity Insulator Weight 2.4kg Weight 1.6 kg ( 2 pieces) Material Polyurethane Material Polyurethane, non-woven textiles Clean Waker Tray Inclined tray for easy trolley access CW-T900 This dedicated tray is perfect for the Clean Walker size. The inclination allows trolleys to pass over without catching. Clean Walker mats can be removed with a little pull. NEW Directive Specifications Model No. CW-T900 Color Blue Size W1000mm×L600mm×t5mm Conductivity Insulator Weight 2.45kg Material EPDM+SBR 32 Options and replacement parts Electrode Needle Unit / Front Cover Electrode Needle Unit Electrode Needle Unit Front cover w/needle electrode EDP No. 806094 EDP No. 806053 EDP No.806127 Electrode Needle Plate Front Cover with Integrated Electrode Needles Front cover w/needle electrode EDP No. 806071 EDP No.806128 F-6H SF-9H Use with: F6CL-E, F6ST-E F-120CH Use with: SFQ9-E F-12EH EDP No. 806055 Use with: 3F-12-E Use with: F120-E CF-30H F-120SCH Use with:CF-30-E Use with: F120S-E Filter Filter Set Filter Set SDJ-08F SF-9F SF-Q9F F-120FS F-120FF CF-30F EDP No. 806039 EDP No. 806052 EDP No. 621707 EDP No. 806123 EDP No. 806054 EDP No. 806072 Use with: F6CL-E, F6ST-E Use with: SFQ9-E Use with: SFQ9-E Use with: F120-E,F120S-E Use with:3F-12-E,F120-E,F120S-E Use with: CF-30-E AC Adapter AD24-ITF6-E AD24-IT-EX AD24-ITCF AD24-IT19 EDP No. 806096 EDP No. 806050 EDP No. 806074 EDP No. 806080 I / P : AC100V~240V 0.4A O/P : DC24V 0.75A I / P : AC100V~240V 0.4A O/P : DC24V 0.75A I / P : AC100V~240V 1.2A O/P : DC24V 1.5A I / P : AC100V~240V 1.2A O/P : DC24V 1.9A Use with: F6CL-E, F6ST-E Use with: SFQ9-E,F120-E, F120S-E Use with: CF-30-E Use with: 3F-12-E For Gun / Nozzle Type Standard Nozzle N-2TN EDP No. 806057 EDP No. 806085 Use with:G7R-E, N-2, N-1 Use with:G7R-E Silent Nozzle Straight Silent Nozzle Shower Tube N-2C6B EDP No. 621706 Use with:N-2 (A combination of N-2TN) Standard Nozzle Flared Nozzle N-2FN EDP No. 806086 Use with:G7R-E, BBZ-E, N-2, N-1 Corner Nozzle N-2WN BB-ZSN N-1SN N-1CN EDP No. 806087 Use with:G7R-E, BBZ-E, N-2, N-1 EDP No. 621708 Use with:G7R-E, BBZ, N-2, N-1 EDP No. 806120 Use with:N-1 EDP No. 806121 Brush: 60 mm bristles G-7B EDP No. 806059 Use with:G7R-E Electrode Needle Replacement Screwdriver G-7DR EDP No. 806061 Use with:G7R-E, BBZ-E, N-2, N-1 AC Adapter Soft Brush: 60 mm bristles Electrode Needle N-1H EDP No. 806062 EDP No. 806056 Use with:G7R-E, BBZ-E, N-2 EDP No. 806122 Use with:G7R-E Speed Controller G-7F EDP No. 621373 EDP No. 621702 Use with:G7R-E, BBZ-E, N-2, N-1 AC Adapter Use with:G7R-E, BBZ-E, N-2, N-1 AC Adapter EDP No. 806067 EDP No. 806076 Use with: BBZ-E EDP No. 806050 Relay Cable (10 m) Use with:N-1 Microfilter G-7SC AD24-IT-EX Use with: N-2, N-1 G-7EC5 G-7EC10 EDP No. 621703 EDP No. 621704 Use with: N-2, Relay cables are used to connect the G7R-E to its dedicated power supply transformer (AD24-ITC-E). Use this case when unstable N-2 with Noise seen. Use with: G7R-E, (A combination of AD24-ITC) Electrode Needle G-7H AD24-ITB-E Relay Cable (5 m) Use with:N-1 G-7SB AD24-ITC-E Use with: G-7RE 33 Tube-fitting Nozzle G-7SN Shieled Case Filter eliminates at least 99% of particles with a diameter of 0.01 μm or greater. Install a 1 μm to 10 μm air filter and mist separator on your air compressor before using this item. Fan Type Nozzle Type Gun Type Bar Type Ion Parts Cleaner EPA Working Mat Clean Walker Options For PAC-8 G7R-E Connection Cable AC Adapter G-7RC (2.5m) EDP No. 621705 AD24-ITC-E EDP No. 806067 (A combination of G7R-E) For C-series Remote Control Power Supply Cable C-00H RMC-01 EDP No. 806106 EDP No. 806104 EDP No. 621533 Electrode Needle Unit CT-5 (A combination of AC Adapter) AC Adapter AC Adapter AC Adapter AD24-IT-EX AD24-ITCF AD24-IT19 EDP No. 806050 EDP No. 806074 EDP No. 806080 I / P : AC100V~240V 0.4A O/P : DC24V 0.75A I / P : AC100V~240V 1.2A O/P : DC24V 1.5A I / P : AC100V~240V 1.2A O/P : DC24V 1.9A Operation:One bar Operation:Two bars Operation:Three bars For B-series Electrode Needle Unit B-00H End Brackets (set of 2 with set screws) Middle Bracket (with set screws) EDP No. 806102 EDP No. 806103 B-EB EDP No. 806101 Remote Control RMC-01 B-MB EDP No. 806104 Power Supply Cable Branch Adapter Power Supply Separator EDP No. 621531 EDP No. 621532 B-SP2 CT-5 B-SP3 AC Adapter EDP No. 621533 (A combination of AC Adapter) AC Adapter AC Adapter AD24-IT-EX AD24-ITCF AD24-IT19 EDP No. 806050 EDP No. 806074 EDP No. 806080 I / P : AC100V~240V 0.4A O/P : DC24V 0.75A I / P : AC100V~240V 1.2A O/P : DC24V 1.5A I / P : AC100V~240V 1.2A O/P : DC24V 1.9A Operation:One bar Operation:Two bars Operation:Three bars Branch Box Relay Cable (3 m ) Relay Cable (5 m) EDP No. 621552 EDP No. 621553 EDP No. 621554 For SH-series SH-SP2 SH-EC3 SH-EC5 For Ion Parts Cleaner HEPA filter Cartridge Medium-efficiency filter Cartridge (Collects 99.7% of the 0.3µm Particles or larger) Use with: IPC20-E, IPC40-E, IPC60-E Use with: IPC20-E, IPC40-E, IPC60-E Unwoven fan filter (5pc.) IPC-A4F EDP No. 806092 Use with: IPC-A4 Paper pack filter (6pc.) IPC-A3F Use with: IPC-A3 Adhesive gel sheet (1pc) Electrode Needle (For N-1) IPC-A4G N-1H EDP No. 806091 EDP No. 806122 Use with: IPC-A3, IPC-A4 (two sheets required per unit ) Use with: IPC-A3, IPC-A4 For EPS-01 Replacement Bands (5-piece set /one with a dedicated tool ) EPB-01 EDP No. 621395 Use with: EPS-01, EPS-01G 34 VESSEL CO., INC 17-25, Fukae-kita 2-chome, higashinari-ku, Osaka 537-0001 JAPAN Tel : +81(0)6 6976 7778 Fax : +81(0)6 6972 9441 ●Product specifications, dimensions, pricing, and other information are subject to change without notice. ●Static electricity erasing capability values given in this catalog were obtained in our measurement environment. Your results may differ depending on the operating environment. Distributed by VESSEL EUROPE 6, avenue du 1er Mai, ZAE Les Glaises, 91120 Palaiseau FRANCE Tel : +33(0)1 69 19 17 42 Fax : +33(0)1 69 19 42 20 E-mail : [email protected] Printed in Japan URL : http://www.vessel.co.jp/english/ 13031066.03
© Copyright 2024