Static Control Product Catalog - sml

Static Control Product Catalog
http://www.vessel.co.jp/english/staticelectric/
VESSEL,
Three Particular Reasons people choose VESSEL
01
1
We have the best selection
2
Our product development
aims for user friendliness
3
Our static removal and
dust removal specialists improve
your quality problems
Vessel’s lineup covers a wide range from fan, gun and bar-type air blow ionizers,
EPA mats and wrist straps that prevent static discharge, to adhesive mats that
prevent the scattering of dust. Our products provide solutions to your static
removal and dust removal problems.
To provide optimum products for production sites, our designs aim for ease
of use. VESSEL aims for user convenience with our product lineup for
various applications.
Our static removal and dust removal specialists will visit your production site to
propose the best available products. Customization is also available upon request.
the ionizing and dust elimination expert,
helps solve your quality problems.
Product quality is an important determination at manufacturing sites.
VESSEL has focused on countermeasures against static electricity and dust in relation to quality.
Since 2000, we have provided products to remove static and dust.
All to help improve our customer’s quality.
Let VESSEL, the ionizing and dust elimination experts,
help you improve your product quality.
02
Realize ionizing and clean control from your
VESSEL’s lineup of reliable and wide ranged
Fan Type
Nozzle Type
Gun Type
Mount on a cell workbench,
part shelf or belt conveyor.
Handle close to far distances
by switching the speed.
Assemble into manufacturing
devices for pinpoint neutralization
and dust-elimination within a
confined space. Just replace the
nozzle to use with various
applications.
Ideal for air washing and
neutralization after part acceptance
and before part assembly,
as well as for neutralization and
dust elimination from resin formed
products before painting.
<Mini>
F6CL-E
F6ST-E
P06
N-1
N-2
P12
Bar Type
Suitable for neutralizing clean
rooms, and preventing static
buildup on film moving at high
speeds.
G7R-E
P14
BBZ-E
P14
<Built-in power supply>
C-series
P17
<Standard>
SFQ9-E
P07
<Built-in power supply>
B-series
F120-E
F120S-E
P19
P08
<Wide width>
CF-30-E
P09
<Separate power supply>
3F-12-E
SH-series
P09
P21
SG-H3
P22
P05
03
P11
P13
P15
fingertips to your toes.
static electricity countermeasure products.
Ion Parts
Cleaner
EPA
Working Mat
Perform air washing within static
electricity removal area. Scattered
dust is collected with the dust
collector to maintain a clean
environment.
Clean Walker
ESD control mats for use in areas
where parts are handled,
assembled, repaired and tested.
Available in ESD control mats and
wrist straps.
Adhesive mat, set before a clean
room, collects dust off soles of
work shoes. Non-peeling,
washable type.
Options
Options and replacement parts.
<Gel Dust Collection Type>
IPC-A4
IPC-A3
P24
Electrode
Needle Unit
Conductive Rubber Mat
P28
Electrode
Needle Unit
<Clean Walker>
CW-900B
P32
AC Adapter
Filter
Standard Nozzle
Branch Box
Brush
Branch Adapter
Speed Controller
Flared Nozzle
Adhesive Gel Sheet
Electrode Needle
<Dust Collection Chamber built-in Type>
IPC20-E
P25
<ESD Countermeasure Wrist Straps>
EPS-01/01G EPS-03M/S
EPS-02M/S EPS-04/B
<Clean Walker Easy>
CW-900EZ
P32
P29
<Separate Dust Collecter Type>
IPC40-E
P25
IPC-60
P26
<Tray>
<Electrostatic Field Meter>
EYE-01
EYE-02
P23
Measurement
Conditions
CW-T900
P32
SDL-01
P30
P27
P31
P33
Ion balance : 300 mm from the front of the device at maximum airflow setting
Decay time : 300 mm from the front of the device at maximum airflow setting
(given as the time required for the voltage to attenuate from ±1,000 V to ±100V)(Charged plate monitor: 150 mm × 150 mm square, 20 pF)
Noise level :1 m from the front of the device at maximum airflow setting
※Measurement values given in this catalog are typical values from a sample unit, and do not guarantee the performance.
04
Why is VESSEL’s fan type our customer’s top choice?
1
High neutralization performance
through efficient ion generation
Fan Type
The high frequency piezoelectric transformer
generates large volumes of ions, and
eliminates losses caused by recoupling.
F6CL-E/F6ST-E
High-frequency piezoelectric transformer「Piezzo」
Compact and free installation
Pinpoint neutralization
Decay time 3.0 sec or less
SFQ9-E
Dual piezoelectric transformer attains
fastest neutralization in this class
Decay time 1.2 sec or less
F120-E/F120S-E
2
Advanced control technology
with steady ion balance
The capacity coupling type electrode needle
ensures a stable ion balance, and prevents
static destruction of the semiconductor.
NEW
Butterfly louver realizes
high-speed neutralization
Decay time 1.3 sec or less
Electrode Needle Unit
CF-30-E
High-efficiency cross fan
neutralizes over wide range of areas
Decay time 1.4 sec or less
3F-12-E
Providing wide-range static-erasing
on workbench or conveyors
Decay time 1.8 sec or less
05
3
Louver cover improves
serviceability
The cover can be easily removed allowing the
electrode needle to be cleaned where it will
not contaminate the work environment.
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Ionizing Mini Fan with clip
Clean Walker
Options
Ionizing Mini Fan with stand
Clip onto workbench or pillar
for pinpoint neutralization
Compact fan can be installed
anywhere for pinpoint neutralization
F6CL-E
F6ST-E
77
77
131
Low
noise
Fan
Low
noise
Fan
142
81
81
EDP No. 621632
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
3.0 sec or less
Power supply
Fan Speed
HI/LOW
DC24V
LED
illumination
INCLUDED
TRANSFOMER
100-240VAC
Electrode
needle unit
replacement
ALARM FAN
LOCKUP
Directive
ALARM
H.V.
External
grounding
terminal
Install anywhere
Easily remove louvers
Confirm operation status and electrode tip contamination
with built-in light.
EDP No. 621631
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
3.0 sec or less
Power supply
DC24V
Fan Speed
HI/LOW
LED
illumination
INCLUDED
TRANSFOMER
100-240VAC
Electrode
needle unit
replacement
ALARM FAN
LOCKUP
Directive
ALARM
H.V.
External
grounding
terminal
Install anywhere
Easily remove louvers
Confirm operation status and electrode tip contamination
with built-in light.
M5 Screw
M5 Screw
M5 Screw
Clip
Stand
Remove clip when not needed
Easy removal
Built-in light
Remove clip when not needed
Easy removal
Built-in light
Specifications
Specifications
Model No.
F6CL-E
Model No.
F6ST-E
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 3.5kV
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 3.5kV
Power supply and current consumption
DC24V±5%/253mA(typ.)
Power supply and current consumption
DC24V±5%/220mA (typ.)
Ion balance
within ±10 V
Ion balance
within ±10 V
Decay time
3.0 sec or less
Decay time
3.0 sec or less
Operating range
150 mm to 600 mm
Operating range
150 mm to 600 mm
H×W×Dmm
H254×W77×D108mm(clip included)
H×W×Dmm
H142×W90×D82mm(stand included)
Weight
514g
Weight
460g
Fan speed
0.78m3/min(max.)
Fan speed
0.78m3/min(max.)
Noise level
HI 58.5dBA/LO 39.5dBA
Noise level
HI 58.5dBA/LO 39.5dBA
Ozone production
0.05ppm or less(measured 50mm)
Ozone production
0.05ppm or less(measured 50mm)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Accessories
AC adapter AD24-ITF6-E, AC cable(1.8m)
Accessories
AC adapter AD24-ITF6-E, AC cable(1.8m)
Decay area
150
300
300
450
600
Decay area
150
F-6
300
450
600
150
0
2sec
3sec 4sec
6sec
F-6
150
0
2sec
3sec 4sec
6sec
150
300
Accessories
150
300
300
(mm)
AC Adapter
AD24-ITF6-E
EDP No. 806096
Accessories
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
(mm)
AC Adapter
AD24-ITF6-E
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
EDP No. 806096
06
Applications ( F120-E )
Fan-type Ionizer with Integrated Sensor
Ion balance is monitored by a sensor
and adjusted automatically
SFQ9-E
129
69
205
80
141
EDP No. 621626
High VoltageTransformer
Ion balance
Decay time
Dual piezoelectric
high-frequency AC
corona discharge
within ±5 V
1.2 sec or less
Power supply
DC24V
Fan Speed
HI/MD/LO
INCLUDED
TRANSFOMER
LED
illumination
100-240VAC
Electrode
needle unit
replacement
ALARM FAN
LOCKUP
Directive
ALARM
H.V.
External
grounding
terminal
Our original feedback sensor controls the ion balance to within ± 5V.
Dual piezoelectric transformers and high-speed fan provide
double the neutralization speed.
Indicator shows the maintenance timing and fluctuations in ion balance.
Ion blance indicator
Dual piezo
Interior LED light
Specifications
Model No.
SFQ9-E
Ionizing method/Applied voltage
Piezoelectric high-frequency DC corona discharge/DC±4 to ±8kV
Power supply and current consumption
DC24V±5%/340mA(typ.)
Ion balance
within ±5 V
Decay time
1.2 sec or less
Operating range
150 mm to 900 mm
H×W×Dmm
H205×W141×D80mm(stand included)
Weight
966g
Fan speed
1.8m3/min (max.)
Noise level
HI 49.6dBA/LO 38.8dBA
Ozone production
0.05ppm or less(measured 50mm)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Accessories
AC adapter AD24-IT-EX AC cable(1.8m)
Decay area
150
150
SF-9
0
300
450
0.5sec 1sec
2sec
150
Accessories
3sec
750
900
4sec
(mm)
AC Adapter
AD24-IT-EX
EDP No. 806050
07
600
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Fan-type Ionizer
Fan-type Ionizer
Butterfly Louver !
for wider and far reach static erasing area
Silent fan model
with mild airflow
F120-E
NEW
F120S-E
NEW
69.5
69.5
198
198
68
68
162
162
EDP No. 621642
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
1.3 sec or less (F-120)
2.5 sec or less ( F-120S)
Power supply
Fan Speed
HI/MD/LO
DC24V
INCLUDED
TRANSFOMER
LED
illumination
100-240VAC
Electrode
needle unit
replacement
Directive
ALARM FAN
LOCKUP
ALARM
H.V.
External
grounding
terminal
Butterfly Louver. Press outer side to desperse air.
Press center to let air out straight.
Apparent operation status indication. The new alarm function uses
a 2-color LED. The red light indicates various errors.
Easy maintenance.The electrode needle unit is set into the front cover.
Butterfly Louver
Options
RUN lamp LED
EDP No. 621646
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
1.3 sec or less (F-120)
2.5 sec or less ( F-120S)
Power supply
Fan Speed
HI/MD/LO
DC24V
LED
illumination
INCLUDED
TRANSFOMER
100-240VAC
Electrode
needle unit
replacement
Directive
ALARM FAN
LOCKUP
External
grounding
terminal
ALARM
H.V.
Butterfly Louver. Press outer side to desperse air.
Press center to let air out straight.
Apprent operation status indication. The new alarm function uses
a 2-color LED. The red light indicates various errors.
Easy maintenance.The electrode needle unit is set into the front cover.
Electrode Needle Unit
Butterfly Louver
RUN lamp LED
Electrode Needle Unit
Specifications
Specifications
Model No.
F120-E
Model No.
F120S-E
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 10kV(p-p)
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 10kV(p-p)
Power supply and current consumption
DC24V±5%/700mA(max.)
Power supply and current consumption
DC24V±5%/700mA(max.)
Ion balance
within ±10 V
Ion balance
within ±10 V
Decay time
1.3 sec or less
Decay time
2.5 sec or less
Operating range
150 mm to 900 mm
Operating range
150 mm to 900 mm
H×W×Dmm
H198×W162×D70mm
H×W×Dmm
H198×W162×D69.5mm
Weight
0.9kg
Weight
0.9kg
Fan speed
3.66m3/min (max.)
Fan speed
2.21m3/min (max.)
Noise level
HI 62.1dBA
Noise level
HI 50.7dBA
Ozone production
0.05ppm or less(measured 50mm)
Ozone production
0.05ppm or less(measured 50mm)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Accessories
AC adapter AD24-IT-EX AC cable(1.8m)
Accessories
AC adapter AD24-IT-EX AC cable(1.8m)
Decay area
Decay area
Straight (F120-E)
150
300
300
Wide (F120-E)
450
600
750
900
150
300
Straight (F120S-E)
300
450
600
750
300
150
300
Wide (F120S-E)
450
600
750
3sec
4sec
900
300
150
300
450
600
3sec
1.5sec
F-120
0
1sec
300
Accessories
1.5sec
2sec 3sec
F-120
(mm)
300
AC Adapter
AD24-IT-EX
EDP No. 806050
0
2sec
1sec
F-120S
(mm)
1.5sec
300
Accessories
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
2sec
F-120S
(mm)
300
AC Adapter
AD24-IT-EX
1.5sec
2sec 3sec 4sec
(mm)
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
EDP No. 806050
08
Wide-type Ionizer with Cross-flow Fan
Overhead Triple-fan Ionizer
Compact, low-profile design
saves space
Erases static electricity over a large area by
installing above your work bench or conveyor belt
CF-30-E
3F-12-E
300
130
900
87
125
182
100
80
210
EDP No. 621375
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±5 V
1.4 sec or less
Power supply
DC24V
No-step
airflow
volume
changeover
LED
illumination
Electrode
needle unit
replacement
INCLUDED
TRANSFOMER
100-240VAC
Directive
ALARM FAN
LOCKUP
ALARM
H.V.
External
grounding
terminal
Maintains an ion balance of ±5 V using capacitive-coupled
electrode needles.
LED indicator lights up progressively to indicate airflow.
LEDs all flash after 200 hours of operation to indicate cleaning time.
EDP No. 621378
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±5 V
1.8 sec or less
Power supply
DC24V
No-step
airflow
volume
changeover
LED
illumination
Electrode
needle unit
replacement
INCLUDED
TRANSFOMER
100-240VAC
ALARM FAN
LOCKUP
External
grounding
terminal
ALARM
H.V.
Disk-shaped capacity coupled electrode realizes ± 5V ion balance.
Equipped with 24 VDC service power (300 mA).
Error signal output terminal provided to facilitate assembly into systems.
Unit Rear Side
①②③④⑤
DC24V 300mA max.
Warning Drive Circuit
FAN ALARM
Warning Drive Circuit
H.V. ALARM
LOAD (MAX 50mA)
LOAD (MAX 50mA)
High-efficiency
cross-flow fan built in
LED display and airflow
volume adjustment knob
Capacitive-coupled
electrode needles
Specifications
Electrode Needle Plate
Alarm Output Connection
Specifications
Model No.
CF-30-E
Model No.
3F-12-E
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC p-p9kV( )
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 2.4kV
Power supply and current consumption
DC24V±5%/ 650mA(max.)
Power supply and current consumption
DC24V±5%/1200mA(max.)
Ion balance
within ±5 V
Ion balance
within ±5 V
Decay time
1.4 sec or less
Decay time
1.8 sec or less
Operating range
150 mm to 900 mm
Operating range
150 mm to 900 mm
H×W×Dmm
H125×W310×D130mm
H×W×Dmm
H182×W913×D100mm(stand included)
Weight
2.1㎏
Weight
5.3 ㎏
Fan speed
1.58m3/min(max.)
Fan speed
3.4m3/min(max.)
Noise level
HI 51.2dBA/LO 42.5dBA
Noise level
HI 54.9dBA/LO 45.3dBA
Ozone production
0.05ppm or less(measured 50mm)
Ozone production
0.05ppm or less(measured 50mm)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Accessories
AC adapter AD24-ITCF-EX AC cable(1.8m)
Accessories
AC adapter AD24-IT19 AC cable(1.8m)
Decay area
Decay area
150
150
300
450
600
750
900
150
450
300
450
600
750
900
1050
1200
6sec
CF-30
0
2sec
3sec
150
Accessories
5sec
(mm)
AC Adapter
AD24-ITCF-EX
EDP No. 806074
09
4sec
3F-12
0
3sec
450
Accessories
I / P : AC100V~240V 1.2A
O/P : DC24V 1.5A
2sec
4sec
6sec
(mm)
AC Adapter
AD24-IT19
EDP No. 806080
I / P : AC100V~240V 1.2A
O/P : DC24V 1.9A
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
VESSEL ionizers for a variety of applications.
Inspection process
Dust prevention on molded parts
Static electricity removal in a bottle
Dust and/or static electricity removal from large resin parts
Film unwinding and winding
Glass substrate transfer
Transforming an assembly desk into a simplified clean booth
Static electricity removal from films and/or products
10
Why is VESSEL’s nozzle type our customer’s top choice?
1
LED indicators clearly
indicate the operating status
The bright LED lamps show the operating
state even when installing in dark systems.
Nozzle Type
N-1
NEW
Ultra-compact slim body
Rotary nozzle increases
installation choices
2
Diverse lineup of optional nozzles
support various applications
Use the optional shower nozzle or silent nozzle.
Decay time 0.7 sec or less
N-2
Operation status displayed on LED lamps
Interchangeable nozzle increases
suitable applications
Decay time 0.7 sec or less
3
Daisy-chain the power cables to
keep high-voltage cables inside
and ensure safety
Power can be supplied to multiple units by
daisy-chaining them. 24 VDC wiring enhances
safe connection.
11
Nozzle Type
Fan Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
Super Slim Nozzle-Type Ionizer
Pinpoint Nozzle Ionizer
Super Compact Slim Body.
A rotating nozzle enables to ionize anywhere
Featuring an LED indicator that communicates
the device’s operating status at a glance
N-1
NEW
N-2
27.5
27.5
28
109.6
28
45
107.3
95
Standard Nozzle
(Straight)
45
Replaceable Nozzle
Corner Nozzle
(Elbow)
EDP No. 621639
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
0.7 sec or less
Power supply
DC24V
Power supply:
AIR/N2
max 0.6MPa
LED
illumination
AC Adapter
(Option)
Screw-type
needle
electrode
Directive
“ON” lamp
ALARM
H.V.
External
grounding
terminal
Super slim and compact design enabling to be installed at any place
for any direction. 27.5mm×28mm.
Change the blow direction by turning the rotary corner nozzle.
EDP No. 621615
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
0.7 sec or less
Power supply
DC24V
Power supply:
AIR/N2
max 0.6MPa
LED
illumination
AC Adapter
(Option)
Screw-type
needle
electrode
Directive
External
grounding
terminal
ALARM
H.V.
“ON” lamp
Easy to wire with connector terminals.
Diverse nozzles support various applications.
The nozzle position clicks
at 90° intervals
(w/corner nozzle)
Alarm outputs and daisy chains possible.
Specifications
Standard Nozzle
(included as accessory)
Flared Nozzle can
be angled appropriately
(included as accessory)
Tube-fitting Nozzle provides
connection with air tube.
(included as accessory)
Alarm outputs
and daisy chains.
Specifications
Model No.
N-1
Model No.
N-2
Ionizing method/Applied voltage
Piezo high-frequency AC Corona discharge method/AC10kV(p-p)
Ionizing method/Applied voltage
Piezo high-frequency AC Corona discharge method/AC6kV(p-p)
Power supply and current consumption
DC24V±5%/58mA(typ.)
Power supply and current consumption
DC24V±5%/100mA(typ.)
Ion balance
within ±10V (standard nozzle・0.3MPa、150mm)〔measured values〕
Ion balance
within ±10V (standard nozzle・0.3MPa、150mm)〔measured values〕
Decay time
0.7 sec or less (standard nozzle・0.3MPa、150mm)〔measured values〕
Decay time
0.7 sec or less (standard nozzle・0.3MPa、150mm)〔measured values〕
Operating range
50 mm to 600 mm
Operating range
50 mm to 600 mm
H×W×Dmm
L109.6×W27.5×H28mm (with standard nozzle mounted)
H×W×Dmm
L95×W45×H45mm
Weight
62 g (with standard nozzle mounted)
Weight
106 g (with standard nozzle mounted)
Air supply hose diameter
tube fitting Φ6mm
Air supply hose diameter
tube fitting Φ6mm
Operating fluid
Clean dry air (0.1MPa to 0.3MPa). nitrogen N2 (0.1MPa to 0.3MPa)
Operating fluid
Clean dry air (0.1MPa to 0.6MPa). nitrogen N2 (0.1MPa to 0.6MPa)
Airflow
181ℓ/min(With standard nozzle mounted at 0.3MPa)
Airflow
217ℓ/min(With standard nozzle mounted at 0.3MPa)
Ozone production
0.05ppm or less (measured 50mm)
Noise level
92dBA(With standard nozzle mounted at 0.3MPa)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Ozone production
0.05ppm or less (measured 50mm)
Accessories
Standard Nozzle (included with device), Corner Nozzle
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
Accessories
Standard Nozzle (included with device), Flared Nozzle (N-2FN),
Tube- fitting Nozzle (N-2TN), Power supply harness
Decay area
Decay area
Air Pressure : 0.3MPa
<with Standard Nozzle installed>
50
150
Standard
Nozzle
100
0.6sec
0
200
<with Corner Nozzle installed>
300
50
150
0.8sec
0.7sec
0
100
0.6sec
200
0.7sec
300
0.8sec
Air Pressure : 0.3MPa
<with Flare Nozzle installed>
50 150
300
150
0
450
600
2.0sec
(mm)
<Tube fitting Nozzle installed>
(mm)
150
(mm)
0.5sec 1.0sec
150
(mm)
0
1.5sec
2.0sec
0
2.5sec
(mm)
1.0秒 1.5sec 2.0sec
150
Accessories
Standard Nozzle
Corner Nozzle
N-1SN
N-1CN
EDP No. 806120
EDP No. 806121
1.5sec
150
150
Accessories
600
<Tube fitting Nozzle and Shower Tube installed>
(Tube 300mm long installed)
150
150
0
1.0sec 1.5sec
150
Corner
Nozzle
<with Standard Nozzle installed>
50 150
300
450
150
Flared Nozzle
Tube-fitting Nozzle
N-2FN
N-2TN
EDP No. 806086
EDP No. 806085
(mm)
Electrode Needle
Replacement Screwdriver
(separately sold)
G-7DR
EDP No. 806061
12
Why is VESSEL’s gun type our customer’s top choice?
1
The bright white LED lamp
makes dust visible
Use the LED lamp to check dust that has
adhered on the workpiece.
Gun Type
2
G7R-E
Compact and lightweight
High discharge air blow ionizer
Decay time 0.5 sec or less
Piezoelectric transformer enhances
safety with no need to expose
high-voltage cables
The high-voltage cable is not exposed, so
there’s no need to worry about current leaks or
electric shock caused by wire breakage.
BBZ-E
Eliminate dust and static electricity
for wide area.
Silent and highly durable
Decay time 0.5 sec or less
3
Ergonomically designed grip is
easy to hold and adjusted to
the optimum angle
The nozzle direction faces the optimum
direction when the grip is held, allowing work to
be started right away.
13
Fan Type
Gun Type
Nozzle Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
Gun-type Ionizer
Gun-type Ionizer
Our most popular ionizing air gun is compact,
lightweight and user-friendly
Silent and high durability model
ideal for air blowing in wide areas
G7R-E
BBZ-E
36
105
132
36
150
152
EDP No. 621615
EDP No. 621621
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
0.5 sec or less
Air Pressure
max 0.6MPa
Power supply
DC24V
LED
illumination
Screw-type
needle
electrode
INCLUDED
TRANSFOMER
100-240VAC
Directive
“ON” lamp
ALARM
H.V.
External
grounding
terminal
Ideal for neutralization and dust elimination of precision parts at hand,
for example, in cell production.
Our diverse lineup of options supports various applications.
Our tough 2.5 m robot cable withstands up to 150,000 bends.
Attach a brush to blow out dust
Operating and malfunction alarm LEDs
are provided on both sides of the grip
Specifications
High VoltageTransformer
Ion balance
Decay time
Piezoelectric
high-frequency AC
corona discharge
within ±10 V
0.5 sec or less
Power supply
DC24V
Air Pressure
max 0.6MPa
LED
illumination
INCLUDED
TRANSFOMER
100-240VAC
Screw-type
needle
electrode
Directive
“ON” lamp
ALARM
H.V.
External
grounding
terminal
Ideal for standing work such as neutralization and dust elimination
of large plastic products.
Silent nozzle reduces work environment noise.
5m robot cable withstands up to 150,000 bends & screw-in connector
withstands vibration
The long power cable (5 m) allows work
in a widespread area
Silent, high-discharge air nozzle reduces wind noise
Long cable allows work in wide range
Specifications
Model No.
G7R-E
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 2kV
Model No.
BBZ-E
Power supply and current consumption
DC24V±5%/74mA (max.)
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 2kV
Ion balance
within ±10 V (standard nozzle・measured 150mm from device at 0.3 MPa)
Power supply and current consumption
DC24V±5%/74mA(max.)
Decay time
0.5 sec or less (standard nozzle・measured 150mm from device at 0.3 MPa)
Ion balance
within ±10 V (standard nozzle・measured 150mm from device at 0.3 MPa)
Operating range
50 mm to 600 mm
Decay time
0.5 sec or less (standard nozzle・measured 150mm from device at 0.3 MPa)
H×W×Dmm
L105×H150×D36mm
Operating range
50 mm to 600 mm
Weight
198g
H×W×Dmm
L132×H152×D36mm
Air supply hose diameter
tube fitting Φ6mm
Weight
198g
Operating fluid
Clean dry air ( 0.1MPa to 0.6MPa)
Air supply hose diameter
tube fitting Φ6mm
Airflow
200ℓ/min(0.3MPa)
Operating fluid
Clean dry air (0.1MPa to 0.6MPa)
Noise level
90dBA (0.3MPa)
Airflow
200ℓ/min (0.3MPa)
Ozone production
0.05ppm or less(measured 50mm)
Noise level
77.3dBA (0.3MPa)
Ozone production
0.05ppm or less (measured 50mm)
Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH(with no dew condensation or freezing)
AC adapter AD24ITC-E AC cable(1.8m)/ Standard Nozzle
(included with device)
Accessories
Decay area
150
0
150
300
0.5sec 0.6sec
450
0.7sec 1.0sec
600
1.4sec
150
Accessories
AC adapter AD24-ITB-E AC cable (1.8m)
Decay area
Air Pressure : 0.3MPa (with Standard Nozzle installed )
50
Operating environment temperature and humidity 5°C to 40°C/35% to 65% RH (with no dew condensation or freezing)
(mm)
Accessories
150
50
0
Air Pressure : 0.6MPa
150
0.5sec
300
0.7sec
150
G-7SN
EDP No. 806057
0.9sec
600
1.1sec
(mm)
Accessories
Nozzle
Standard
Nozzle
450
Tube fitting
Nozzle
Brush:
60 mm bristles
G-7B
EDP No. 806059
Electrode Needle
Replacement
Screwdriver
G-7DR
EDP No. 806061
AC Adapter
BB-ZSN
AD24-ITB-E
EDP No. 621708
EDP No. 806076
AC Adapter
AD24-ITC-E
EDP No. 806067
14
Why is VESSEL’s bar type our customer’s top choice?
1
Super Fast Static
Electricity Removal
AC pulse method
Generating alternately positive ions and
negative ions from each electrode. Since
ions are generated at the maximum width
of each positive and negative electrode
cycle, the ion volume is high and static
electricity can be removed quickly.
Bar Type
AC pulse
AC
C-series
NEW
Compact and clean design
Super-high speed ionizer
within ±30V
(Distance 1000mm)
B-series
Extensive variations
from 60 cm up to 3 m
Ion balance
Auto Balance Mode
The C series are equipped with a mode to
optimally adjust the ion balance automatically
according to the polarity of the charged
matter. (Target distance: 50 to 100 mm)
within ±30V
(Distance 1000mm)
If Positive Static Articles remained...
SH-series
100mm
Ion balance
NEW
Slim and high-speed ionizer
High-voltage power standalone type
Ion balance
within ±50V
(Distance 1000mm)
More negative ions are generated.
Air purge function
With air purged toward the needle electrod
tip. This not only prevents contamination
at the tip of the electrode needle, but also
carries the generated ions quickly to the
charged object and
removes static
electricity.
15
Fan Type
Nozzle Type
Gun Type
Bar Type
2
Usability
Easy maintenance design
One-touch needle replacement. A socket type needle can
be easily replaced.
*The electrode needle cannot be removed from the SH- series.
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
3
Line-up at a glance
Sizes to match various working
environments
Ionizing bars are available in a variety of sizes for assembly
into small electronic part manufacturing systems to neutralization
of large workpieces such as film and liquid crystal glass.
All bar type series lineup
B-Series
(mm)
Clean design
Needle cleaning time notified
The cleaning interval can be set between one and 60 days,
in one-day units. When the time elapses, the needlecleaning lamp lights up and an alarm displays. *C-series
3000
B-300
2800
B-280
2600
B-260
2400
The ion current is detected. When the ion generation drops,
the ION/TIP lamp turns ON and an alarm displays. *B-series
B-230
B-220
2200
B-210
B-180
1800
Body contamination prevention
Opposing electrodes are incorporated in the body. The
induced voltage prevents particles from sticking to the
outer side of the body, and limits the losses in applied
voltage to improve the ion generation efficiency. *C-series
C-Series
C-200
2000
C-170
B-160
1600
B-150
B-140
1400
C-150
1200
The opposing
electrodes
are incorporated
Angle adjustment
1000
800
SH-Series
600
SH-70
SH-60
B-120
C-120
B-100
B-95
B-90
C-100
C-90
B-60
SH-50
The angle can be adjusted.
400
200
SH-40
SH-30
SH-20
SH-16
0
16
AC Pulse Ionizing Clean Bar
Clean & Compact.
Newly designed high-precision and high-speed ionizer applying a new technology
C-series
NEW
C-90
C-100
C-120
C-150
C-170
C-200
EDP No. 621851
EDP No. 621852
EDP No. 621853
EDP No. 621854
EDP No. 621855
EDP No. 621856
Common Specifications
Directive
High VoltageTransformer
Ion balance
Pulse AC
corona discharge
within ±30 V (measured 1000 mm)
Model No.
C-90∼C-200
Ionizing method/Applied voltage
Pulse AC Corona discharge/ AC8∼12.5kV(p-p)
frequency
0.1 to 50Hz (Select form ten steps)
pulse ratio
Positive ion 40 to 70 %, negative ion 60 to 30%
Power supply and current consumption
DC24V±5%/600mA (max.)
Ion balance
within ±30V (Distance 1000mm)
Newly designed super-fast ionizing air discharge port
Decay time
See below
Auto Balance Mode (Target distance: 50 to 100 mm)
Operating range
50 to 2000mm
H×W×Dmm
Refer to the figure on the right
Weight
Refer to the figure on the right
Air supply hose diameter
PT1/8
Operating fluid
Clean dry air or nitrogen (N2) (0. 3 MPa or less)
Power supply
DC 24V
±5%
Air Pressure
max 0.3MPa
Electrode
needle unit
replacement
LCD
Display
Adjustable
Ion
Balance
Needle
Cleaning Timer
ALARM
H.V.
(1 to 60 days)
External
output
LAN Terminal
Terminals grouped on one side. Enabling a daisy-chain connection.
DC24V
Power Supply
Module
Power Supplu Cable (attached)
Interface Terminal
Cat 5 Cable (locally sold)
Ozone production
0.05ppm or less (measured 50mm)
Operating environment temperature and humidity
5°C to 40°C/35% to 85% RH (with no dew condensation or freezing)
Accessories
Remote controller / Power cable (5m) /
End brackets (included with device) /
Middle bracket (included with device / C-90 is excluded)
*Silicon discharge needles also available. For more detail please contact us.
Daisy Chain Possible
Measurement conditions ・Product : C-150 ・Voltage : 10.5kV(P-06 N-06) ・Air pressure : 0.3MPa ・Temperature : 24°C±1°C
・Humidity : 40%±2%RH ・Decay time : ±1000V→±100V ・CPM : 20pF±2pF(150x150mm)
Frequency: 0.1Hz
-150
-100
-50
0
50
100
150
(mm)
300
-150
300
-100
-50
AD24-IT-EX
0
50
100
1sec
600
600
150
2sec
900
900
1sec
1200
left wing
1200
4sec
1500
6 sec
right wing
left wing
(Operatable with One Bar type IONIZER only)
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
EDP No. 806050
AC Adapter
AD24-ITCF-EX
3sec
(Operatable with Two Bar type IONIZERS only)
I / P : AC100V~240V 1.2A
O/P : DC24V 1.5A
5sec
2 sec
3 sec
1500
Options
AC Adapter
Frequency: 30Hz
(mm)
Decay area
EDP No. 806074
AC Adapter
right wing
AD24-ITCF-EX
(Operatable with Three Bar type IONIZERS only)
Frequency: 1Hz
-100
-50
600
0
50
100
-150
300
-100
-50
1sec
900
5 sec
left wing
17
6sec
right wing
150
EDP No. 806080
RMC-01
EDP No. 806104
3 sec
4 sec
1200
4 sec
100
Remote Control
3 sec
1500
50
2 sec
2 sec
1200
0
600
1sec
900
150
(mm)
-150
(mm)
300
I / P : AC100V~240V 1.2A
O/P : DC24V 1.9A
Frequency: 50Hz
Power Supply Cable(5m)
5 sec
6 sec
1500
left wing
CT-5
EDP No. 621533
right wing
Fan Type
Nozzle Type
Gun Type
Ion Parts
Cleaner
Bar Type
EPA
Working Mat
Clean Walker
Options
70
33
33
60
70
70
60x23=1380
800
40
65
78
1520
4-φ5x13
2-φ5x10
(785.5)
1571
877
1597
Electrode needles : 12pcs.
Middle bracket : No
Weight : 1.8kg
33
70
33
60
(545.5)
78
4-φ5x13
(603.7)
(545.5)
1811
1117
1837
4-φ5x13
(603.7)
33
33
60
60x31=1860
70
(665.5)
(683.7)
78
40
40
65
4-φ5x13
65
2-φ5x10
78
65
(665.5)
33
2000
1280
40
70
52.5
92.5
33
70
60x19=1140
52.5
60
C-200
92.5
Electrode needles : 28pcs.
Middle bracket : 2
Weight : 1.6kg
C-120
78
4-φ5x10
(603.7)
1091
Electrode needles : 16pcs.
Middle bracket : 1
Weight : 1.0kg
40
65
78
2-φ5x10
40
65
40
65
33
1760
1040
70
70
60x27=1620
52.5
92.5
33
70
60x15=900
52.5
60
C-170
92.5
Electrode needles : 12pcs.
Middle bracket : 1
Weight : 1.4kg
C-100
78
4-φ5x13
(785.5)
851
70
33
52.5
33
60x11=660
52.5
60
70
C-150
92.5
C-90
92.5
(Unit:mm)
4-φ5x10
(683.7)
4-φ5x13
(683.7)
2051
1331
2077
1357
Electrode needles : 20pcs.
Middle bracket : 1
Weight : 1.2kg
Electrode needles : 32pcs.
Middle bracket : 2
Weight : 1.8kg
Frequency
Voltage Level
The frequency can be set in ten steps (0.1 to 50 Hz).
The applied voltage can be changed individually for the positive and Film
negative side. The amount of ions can be changed by different output steps.
(Ten steps: 8.0 to 12.5 kVp-p)
Film manufacturing
Close distance: 50 to 300mm
Clean room bench
Medium distance: 600 to 750mm
Clean room ceiling
Voltage level
1
Positive voltage (kV)
4
4.25 4.5 4.75
5
Negative voltage (kV)
4
4.25 4.5 4.75
kV p-p
8
8.5
Far distance: 900 to 1500mm
Pulse Ratio
The ion balance can be adjusted by changing the
pulse ratio.
2
3
9
4
9.5
5
6
7
9
10
5.25 5.5 5.75
6
6.25
5
5.25 5.5 5.75
6
6.25
10
10.5
12
12.5
11
8
11.5
Example of power connection
Address
When using multiple units, an address allocation
(1 to 16) can be set to identify each device.
Power cable : CT-5
Power adapter
18
AC Pulse Ionizing Bars
AC pulse bar with various setting functions to support your application
B-series
B-60
B-90
B-95
B-100
B-120
B-140
B-150
B-160
High VoltageTransformer
Ion balance
Pulse AC
corona discharge
within ±30 V (measured 1000 mm)
Air Pressure
max 0.3MPa
Electrode
needle unit
replacement
LCD
Display
Adjustable
Ion
Balance
Needle
Cleaning
Timer
ALARM
H.V.
External
output
LAN Terminal
Possible to eliminate electricity equally by changing the intervals
between needle electrodes.
The ion balance adjustmrent function enables use of the device
in a variety of applications.
Electrode needle units twist off for easy replacement.
3.65 3.65 3.65
Decay area
55
55
55
55
55
※ B-260/280/300 are made-to-order items.
Model No.
B-60∼B-300
Ionizing method/Applied voltage
Pulse AC Corona discharge/AC8∼12.5kV (p-p)
frequency
0.1 to 50Hz (Select f rom ten steps)
pulse ratio
Positive ion 40 to 70 %, negative ion 60 to 30%
Power supply and current consumption
DC24V±5%/600mA (max.)
Ion balance
within ±30V (Distance 1000mm)
Decay time
See below
Operating range
50 to 2000mm
H×W×Dmm
Refer to the figure on the right
Weight
Refer to the figure on the right
Air supply hose diameter
PT1/8
Operating fluid
Clean dry air or nitrogen (N2) (0.3 MPa or less)
Ozone production
0.05ppm or less (measured 50mm)
Operating environment temperature and humidity
5°C to 50°C/35% to 85% RH (with no dew condensation or freezing)
Accessories
Remote controller / Power cable (5m) /
End brackets (included with device) /
Middle bracket (included with device) / B-60 to B-140 is excluded)
55mm
Measurement conditions ・Product : B-100 ・Air pressure : 0.3MPa
Frequency: 0.1Hz
-100
Frequency: 50Hz
Frequency: 0.3Hz
-50
0
50
100
600
150
(mm)
-150
300
EDP No. 621519
EDP No. 621520
EDP No. 621521
EDP No. 621522
EDP No. 621523
EDP No. 621524
EDP No. 621525
-150
300
-100
-50
0
50
600
100
150
-150
300
-100
-50
0
900
0-3 sec
1200
3-6 sec
1500
12-15sec
3-6sec
left wing
6-9sec
1200
6-9sec
6-9 sec
12-15 sec
1500
right wing
left wing
150
3-6sec
900
1200
100
0-3sec
600
0-3sec
900
50
(mm)
DC 24V
±5%
B-180
B-210
B-220
B-230
※ B-260
※ B-280
※ B-300
Common Specifications
Directive
(mm)
Power supply
EDP No. 621511
EDP No. 621512
EDP No. 621513
EDP No. 621514
EDP No. 621515
EDP No. 621516
EDP No. 621517
EDP No. 621518
12-15sec
1500
right wing
left wing
right wing
Options
AC Adapter
19
AC Adapter
AC Adapter
AD24-IT-EX
AD24-ITCF-EX
AD24-ITCF-EX
(Operatable with One Bar type IONIZER only)
(Operatable with Two Bar type IONIZERS only)
(Operatable with Three Bar type IONIZERS only)
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.5A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.9A
EDP No. 806050
EDP No. 806074
EDP No. 806080
Power cable(5m)
Branch Adapter
Power Supply Separator
EDP No. 621533
EDP No. 621531
EDP No. 621532
CT-5
B-SP2
B-SP3
Fan Type
Nozzle Type
Gun Type
Ion Parts
Cleaner
Bar Type
EPA
Working Mat
Clean Walker
B-90 ∼300
B-60
Options
(Unit:mm)
D±2.5
660±2.5
C±2.5
=
10
=
4-φ5X9
78
40
23
23
2-φ5X9
18
30
30
18
65
4-φ5X9
640±2.5
62
480±2.5
36.5
34.4
604±2.5
109.5
68.5
A1±2.5
A±2.5
B±2.5
A'
55
109.5
36.5
6.5
40 40 40 40 40 40 40 40 40 40 40 40
62
6.5
70
33
109.5
33
70
109.5
A
34.4
68.5
45°
90°
SECTION A-A'
Dimension/Electrode needles/Middle Blacket
Model No.
A (mm)
A1 (mm)
B (mm)
C (mm)
D (mm)
Electrode needles
Middle Blacket
Weight (kg)
B-60
480
ー
604
640
660
13pcs.
0
1.2
B-90
769
550
906
942
962
17pcs.
0
1.5
B-95
824
605
961
997
1017
18pcs.
0
1.6
B-100
934
715
1071
1107
1127
20pcs.
0
1.6
B-120
1099
880
1236
1272
1292
23pcs.
0
1.8
B-140
1264
1045
1401
1437
1457
26pcs.
0
2.0
B-150
1374
1155
1511
1547
1567
28pcs.
1
2.1
B-160
1484
1265
1621
1657
1677
30pcs.
1
2.2
B-180
1704
1485
1841
1877
1897
34pcs.
1
2.3
B-210
2034
1815
2171
2207
2227
40pcs.
2
2.6
B-220
2144
1925
2281
2317
2337
42pcs.
2
2.7
B-230
2254
2035
2391
2427
2447
44pcs.
2
2.8
B-260
2474
2255
2611
2647
2667
48pcs.
3
3.1
B-280
2694
2475
2831
2867
2887
52pcs.
3
3.3
B-300
2914
2695
3051
3087
3107
56pcs.
3
3.5
Wiring example
When connecting
1 pulse ion bar
Using the included power supply cable
Included power supply cable
Using a CT-5 power supply cable and AD24-IT-EX AC Adapter
Power cable:CT-5
or
AC Adapter:AD24-IT
When connecting
2 pulse ion bars
Using a B-SP2 branch adapter, CT-5 power supply cable, and AD24-ITCF-EX AC Adapter
Branch adapter :B-SP2
Power cable:CT-5
AC Adapter:AD24-ITCF
*LAN cable (commercially available cable)
Ask for a CAT5 LAN cable.
When connecting
3 pulse ion bars
Using a B-SP3 power supply separator, CT-5 power supply cable, and AD24-IT19 power supply transformer
Cable length: Max. 20 m to end of bar
Power supply separator :B-SP3
*You can also use a switching power supply and no AC Adapter
( 24 VDC, max. 10 A ).
*LAN cable (commercially available cable)
Ask for a CAT5 LAN cable.
Power cable:CT-5
AC Adapter:AD24-IT19
20
Compact AC Pulse Ionizing Bars (separate power supply type)
Slim & High-speed Neutralization.
Compact bar type ionizer with separate power supply for easy installation.
SH-series
NEW
SH-16
SH-20
SH-30
SH-40
SH-50
SH-60
SH-70
EDP No. 621541
EDP No. 621542
EDP No. 621543
EDP No. 621544
EDP No. 621545
EDP No. 621546
EDP No. 621547
Directive
High VoltageTransformer
Ion balance
Pulse AC
corona discharge
within ±50 V (measured 1000 mm)
Power supply
DC 24V
±5%
Air Pressure
max 0.3MPa
Positive
and
negative ion
Electrode
needle unit
replacement
Adjustable
Ion
Balance
Needle
Cleaning
Timer
ALARM
H.V.
External
output
LAN Terminal
Air purging functions.
Safe Design. Flexible silicone sheath cable.
Up to three bars can be branched and wired using the branch box (SH-SP2).
Common Specifications
Silicone sheath cable
Flexible silicone sheath cable adopted
Decay area
0
50
0-2sec
600
100
150
(mm)
-50
Pulse AC Corona discharge/AC10.5kV (p-p)
frequency
30Hz
pulse ratio
Positive ion 40 to 70 %, negative ion 60 to 30%
Power supply and current consumption
AC100V∼AC240V/10W (SH-G3)
Ion balance
within ±50V (Distance 1000mm)
Decay time
See below
Operating range
50 to 2000mm
H×W×Dmm
Refer to the figure on the right
Weight
Refer to the figure on the right
Air supply hose diameter
tube fitting Φ6mm
Operating fluid
Clean dry air or nitrogen (N2) (0.5 MPa or less)
Ozone production
0.05ppm or less
Operating environment temperature and humidity
5°C to 55°C/25% to 85% RH (with no dew condensation or freezing)
Accessories
High-voltage cable 2.3m (included with device)
Wiring example
Connecting 1 or 3 pulse ionizing bars to the power supply unit
Frequency: 30Hz
-100
SH-16∼SH-70
Ionizing method/Applied voltage
Air purging functions
Measurement conditions ・Product : SH-50 ・Air pressure : 0.3MPa
-150
300
Model No.
Using an SH-SP2 branch box and SH-EC3 relay cable
2.3m
SH-SP2
2.3m
A
SH-G3
SH-EC3 (3m)
2.3m
900
B
2-4sec
1200
Using an SH-SP2 branch box and SH-EC5 relay cable
4-6sec
1500
2.3m
left wing
A
SH-SP2
SH-G3
SH-EC5 (5m)
right wing
2.3m
Options
B
Power cable:CT-5
Using an SH-SP2 branch box and SH-EC3 relay cable
SH-EC5 (5m)
branch box
Relay Cable(3m)
Relay Cable(5m)
EDP No. 621552
EDP No. 621553
EDP No. 621554
SH-SP2
21
SH-EC3
SH-EC5
SH-SP2
A
SH-G3
SH-EC5 (5m)
*Power supply cable (relay cable) length cannot exceed a total of 10 m to the two high-voltage sockets (A, B).
*Up to three SH bars can be connected from a single power supply unit ( SH-G3 ).
Fan Type
Gun Type
Bar Type
SH-40
Electrode needles : 8pcs.
Weight : 0.36kg
30
27
6.7
405
1.5
16 2
33
30
373
16
2
30
148
1.5
19
409
180
2.3m
2.3m
SH-50
Electrode needles : 13pcs.
Weight : 0.57kg
548
Electrode needles : 10pcs.
Weight : 0.40kg
60
19
530
6.7
52.5 19
420
P35
27
258
135
32.5
30
23
36.4
9
P15
30
33
60
315
P35
184
9
Options
(Unit:mm)
23
36.4
27
30
23
200
6.7
36.4
9
P15
SH-20
Clean Walker
443
47.5 19
105
27.5
EPA
Working Mat
Electrode needles : 10pcs.
Weight : 0.50kg
218
9
Ion Parts
Cleaner
30
SH-16
Nozzle Type
1.5
30
27
23
510
33
184
2
1.5
180
148
16 2
30
33
16
478
30
200
6.7
36.4
514
SH-60
2.3m
Electrode needles : 16pcs.
Weight : 0.63kg
653
60
210
27
619
19
615
33
30
23
27
1.5
P35
6.7
36.4
9
19
23
36.4
338
30
60
P35
6.7
Electrode needles : 7pcs.
Weight : 0.42kg
525
30
16
583
2
30
SH-30
9
30
2.3m
320
304
2.3m
16
2
SH-70
Electrode needles : 19pcs.
Weight : 0.70kg
758
30
60
630
19
27
740
6.7
36.4
2.3m
P35
23
9
30
268
30
33
1.5
300
724
90°
1.5
720
33
2
30
38.5
16
688
2
18
30
2.3m
Power supply units
Power supply units supporting 100 to 240 VAC
SH-G3
200
138
100
80
15
R3
(mm)
61.2
218
1.5
230
Directive
EDP No. 621555
Specifications
Model No.
SH-G3
H×W×Dmm
L230×W138×H62.7mm
Power supply and current consumption
AC100V∼AC240V/10W (SH-G3)
Weight
1.5kg
Accessories
AC power cable 1.8m (for 100 VAC and 240 VAC input) 2 cables
AC power cable
For AC100V
For AC200V
1.8m
1.8m
22
Why is VESSEL’s ion parts cleaner our customer’s top choice?
1
Ion Parts
Cleaner
IPC-A4
Ideal A4 size
for cell workbenches
IPC-A3
NEW
Ideal A3 size
for cell workbenches
Neutralization and dust
elimination inside hoods
Dust adhered with static electricity is neutralized
inside the ionized hood and eliminated with
automatic powerful air blow.
2
Forcibly collecting blown
dust with dust collector
Maintain a clean environment by using air
blow to remove foreign matter from
pre-assembly parts, and prevent dust from
scattering around the area.
IPC20-E
Integrated ionizer
and dust collector
IPC40-E
Separated hood
and dust collector
IPC-60
600mm wide hood
for large workpieces
23
3
Capture dust with
self-adhesive urethane gel
The urethane gel’s adhesive surface
catches any dust blown away by the
ionized air blow. The washable gel sheet
can be used repeatedly.
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
Ion Parts Cleaner
Ion Parts Cleaner
A4 size is ideal for capturing dust with
adhesive urethane gel at cell workbench
A3 size is ideal for capturing dust with
adhesive urethane gel at cell workbench
IPC-A4
IPC-A3
420
NEW
314
323
190
225
150
210
361
411
253
300
Eco-friendry product
Eco-friendry product
EDP No. 621610
EDP No. 621612
Sensor
Air blow
Off delay timer
Diffused reflection
type
Continuous/
pulse blow selection
1 to 30 seconds
Power supply
DC24V
Air Pressure
max 0.5MPa
Ionizer
N-1×1pcs
Pinpoint
L-shape corner
nozzle×1pcs
Directive
(5 steps)
AC adapter
100 to 240V
Regulator
Built-in
Self-adhesive
polyurethane gel
sheets and
non-woven
fabric filter
Integrated
hood/dust
collector
With no built-in dust collector, its power consumption is
substantially reduced.
Dislodged dust will be collected by the adhesive gel sheets.
Select continuous or pulse blow of ionizing dust collection air
from nozzle-type ionizer
Off Time Set
Sensor
Air blow
Off delay timer
Diffused reflection
type
Continuous/
pulse blow selection
1 to 30 seconds
Power supply
DC24V
Air Pressure
max 0.7MPa
Ionizer
N-1×2pcs
Pinpoint
L-shape corner
nozzle×2pcs
Directive
(5 steps)
Regulator
Built-in
AC adapter
100 to 240V
Self-adhesive
polyurethane gel
sheets and
paper pack filter
Integrated
hood/dust
collector
With no built-in dust collector, its power consumption is
substantially reduced.
Dislodged dust will be collected by the adhesive gel sheets.
A paper pack filter can be attached to the exhaust port on
the rear side (standard).
Pulse Set
Self Adhesive GEL collects Dust
Regulator Built-in
Specifications
Filter to Duct Relaceable
Specifications
Model No.
IPC-A4
Model No.
IPCIPC-A3
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 6kV
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 6kV
Power supply
DC24V±5%
Power supply
DC24V±5%
Current consumption
700mA or less
Current consumption
900mA or less
Dust collection airflow
3.5 m3 /min (Built-in fan)
Dust collection airflow
1.13 m3 /min (Built-in fan)
Static pressure
105Pa (Built-in fan)
Static pressure
460Pa (Built-in fan)
Dust collection filter
Self-adhesive polyurethane gel sheets and non-woven fabric filter
Dust collection filter
Self-adhesive polyurethane gel sheets and paper pack filter
H×W×Dmm
H361×W314×D253mm
H×W×Dmm
H411×W420×D300mm
Weight
6kg
Weight
9.5kg
Air supply hose diameter
tube fitting 8mm
Air supply hose diameter
tube fitting Φ8mm
Operating fluid
Clean dry air (0.1MPa to 0.5MPa)
Operating fluid
Clean dry air (0.1MPa to 0.7MPa)
Airflow
150ℓ/min (0.3MPa)
Airflow
190ℓ/min (0.3MPa)
Ozone production
0.05ppm or less (measured 50mm)
Ozone production
0.05ppm or less (measured 50mm)
Operating environment temperature and humidity
5°C to 40°C/35% to 65% RH (with no dew condensation or freezing)
Operating environment temperature and humidity
0°C to 40°C/20% to 80% RH (with no dew condensation or freezing)
Accessories
AC adapter AD24-IT19-EX Pinpoint L-shape corner nozzle×1pc Adhesive gel sheet plate (included with device)×2pcs
Accessories
AC adapter AD24-IT19-EX Pinpoint L-shape corner nozzle×1pc Adhesive gel sheet plate (included with device)×2pcs
Duct flenge (for φ75mm) Paper pack filter (6pc.)
Replacement parts
Replacement parts
Adhesive
gel sheet (1pc)
Electrode
needle (1pc)
Adhesive
gel sheet (1pc)
Electrode
needle (1pc)
Paper pack
filter (6pc.)
IPC-A4G
N-1H
IPC-A4G
N-1H
IPC-A3F
EDP No. 806091
EDP No. 806122
EDP No. 806091
EDP No. 806122
24
Ion Parts Cleaner
Ion Parts Cleaner
Compact, integrated design is ideal for use
in a cell production setting or confined space
Separate type features a dust collector and
standalone hood to make effective use of limited space
IPC20-E
IPC40-E
518
385
450
220
402
345
150
462
678
481
358
326
386
354
EDP No. 621379
Sensor
Air blow
Off delay timer
Diffused reflection
type
Continuous
3sec
( 0.1 to 5 sec )
Power supply
AC100V
Air Pressure
max 0.7MPa
Ionizer
F-6×1pc
Air Nozzle
2pcs
AC
adapter
EDP No. 621380
Directive
Thermal
protector
Mediumefficiency
filter
Integrated
hood/dust
collector
Sensor
Air blow
Off delay timer
Retroreflective
Continuous
3sec
( 0.1 to 5 sec )
Power supply
AC100V
Air Pressure
max 0.7MPa
Ionizer
F-6×1pc
Air Nozzle
2pcs
AC
adapter
Thermal
protector
Directive
Mediumefficiency
filter
Separate
hood/dust
collector
Workpiece is detected with sensor, and dust eliminating air is sprayed.
Flexible nozzle enables pinpoint dust removal from workplaces.
Cylindrical cartridge type medium-efficiency filter incorporated.
Cylindrical cartridge type medium-efficiency filter incorporated.
Compact fan ionizer is ideal for spaces with no static inside the hood.
Compact fan ionizer is ideal for spaces with no static inside the hood.
Drum Filter Cartridge
Specifications
Specifications
Model No.
IPC20-E
Model No.
IPC40-E
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 3.5kV
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 3.5kV
Power supply
AC230V (50/60Hz)
Power supply
AC230V (50/60Hz)
Current consumption
0.42A (50Hz)/0.4A (60Hz)
Current consumption
1.2A (50Hz)/1.4A (60Hz)
Dust collection airflow
1.6 m3 /min (50Hz)/2.0 m3 /min (60Hz)
Dust collection airflow
3.3 m3 /min (50Hz)/4.0 m3 /min (60Hz)
Static pressure
0.35kPa (50Hz)/0.50kPa (60Hz)
Static pressure
0.88kPa (50Hz)/1.23kPa (60Hz)
Table surface controlled air speed
0.8 m/sec (50Hz)/1.0 m/sec (60Hz)
Table surface controlled air speed
0.4 m/sec (50Hz)/0.5 m/sec (60Hz)
Dust collection volume
0.5 L
Dust collection volume
1.2L
Dust collector output
50W
Dust collector output
200 W
Dust collection filter
Medium-efficiency filter (Cylindrical cartridge filter)
Dust collection filter
Medium-efficiency filter (Cylindrical cartridge filter)
H×W×Dmm
H682×W358×D385mm
H×W×Dmm
Hood:H400×W518×D462mm/dust collector:H416×W481×D354mm
Weight
21kg
Weight
Hood:12kg/dust collector:30kg
Air supply hose diameter
tube fitting Φ6mm
Air supply hose diameter
tube fitting Φ6mm
Operating fluid
Clean dry air (0.4MPa to 0.7MPa)
Operating fluid
Clean dry air (0.4MPa to 0.7MPa)
Airflow
355ℓ/min (0.7MPa)
Airflow
355ℓ/min (0.7MPa)
Noise level
56dBA (50Hz)/58dBA (60Hz)
Noise level
62dBA (50Hz)/65dBA (60Hz)
Ozone production
0.05ppm or less (measured 50mm)
Ozone production
0.05ppm or less (measured 50mm)
Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing)
Accessories
25
Plastic adjusting screwdriver for sensor,
hazardous use prohibited display sheet
Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing)
Accessories
Plastic adjusting screwdriver for sensor,
hazardous use prohibited display sheet
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
Ion Parts Cleaner
Featuring a wide 600 mm hood capable
of accommodating large work
IPC-60
668
600
220
402
462
481
326
386
354
*Same Dust Collector as IPC 40-E
EDP No. 621607
Sensor
Air blow
Off delay timer
Retroreflective
Continuous
3sec
( 0.1 to 5 sec )
Power supply
AC100V
Air Pressure
max 0.7MPa
Ionizer
F-6×1pc
Air Nozzle
2pcs
AC
adapter
Thermal
protector
Directive
Mediumefficiency
filter
Separate
hood/dust
collector
Flexible nozzle enables pinpoint dust removal from workplaces.
Cylindrical cartridge type medium-efficiency filter incorporated.
Compact fan ionizer is ideal for spaces with no static inside the hood.
Specifications
Model No.
IPC-60
Ionizing method/Applied voltage
Piezoelectric high-frequency AC corona discharge/AC 3.5kV
Power supply
AC100V±5% (50/60Hz)
Current consumption
3.0A (50Hz)/3.0A (60Hz)
Dust collection airflow
3.3 m3 /min (50Hz)/4.0 m3 /min (60Hz)
Static pressure
0.88kPa (50Hz)/1.23kPa (60Hz)
Table surface controlled air speed
0.4 m/sec (50Hz)/ 0.5 m/sec (60Hz)
Dust collection volume
1.2L
Dust collector output
200 W
Dust collection filter
Medium-efficiency filter (Cylindrical cartridge filter)
H×W×Dmm
Hood:H400×W668×D462mm/dust collector:H416×W481×D354mm
Weight
Hood:147kg/dust collector:30kg
Air supply hose diameter
tube fitting Φ6mm
Operating fluid
Clean dry air (0.4MPa to 0.7MPa)
Airflow
355ℓ/min (0.7MPa)
Noise level
62dBA (50Hz)/65dBA (60Hz)
Ozone production
0.05ppm or less (measured 50mm)
Operating environment temperature and humidity 0°C to 40°C/20% to 80% RH (with no dew condensation or freezing)
Accessories
Plastic adjusting screwdriver for sensor,
hazardous use prohibited display sheet
26
Why is VESSEL’s EPA Working Mat our customer’s top choice?
1
Creating an optimum EPA
environment from work surface,
floor to worker bodies
with a one-stop solution
Our IEC61340-5-1 compliant products include
ESD protection items, workbenches, storage
shelves, EPA working mats for dolly surfaces,
EPA flooring for vinyl floors and painted floors,
and anti-ESD wrist straps.
EPA
Working Mat
Mat
2
Ideal for workbenches needing
static-erasing measures
Steady conductivity performance
Conductivity rates fluctuate easily according to
changes in the working environment’s humidity.
VESSEL’s conductive rubber mats realize a
“conductive performance” that complies with
strict selection standards.
Wrist Straps
Anti-ESD wrist band
[Ω]
×10
Electrostatic
Field Meter
Essential item for static electricity measures
Visual the static charge and discharge state
27
×10
9
8
Conductive Rubber Mat
4.5
×10
1.7
7
Temperature 23℃
Humidity 29%
Temperature 25℃
Humidity 51%
Fan Type
Nozzle Type
Gun Type
Bar Type
EPA
Working Mat
Ion Parts
Cleaner
Clean Walker
EPA Working Mat・Conductive Rubber Mat
Grounding Tap
Controlling electroconductivity to
106Ω or more 107 Ω or less without
influence from the working environment Ideal for workbenches requiring static electricity
measures on backing
Neatly wire the grounding cords
around your workbench
Options
EPS-GT2
EPS-GT2
EPG-01
EDP No. 621402
Specifications
Model No.
EPS-GT2
Size
Approx. 3.0 m (with round jack)
Resistance value
1MΩ
Material
ABS
Mat-connecting gel
10
m LG-100
ROLL
Made from medical-grade conductive gel,
with no need for time-consuming eyelet setting
EDP No. 621464
EDP No. 621461
SG-100
Applications
Conductivity
Material
Designed for use
with work benches
10 6≦R≦10 7Ω
NBR+SBR
EPG-01/EPG-02
Directive
EPA
Offers uniform, consistent conductive performance.
Features a matte surface finish, reducing reflections and helping
prevent eye fatigue prevention.
Heat resistant to dropping solder.
EPG-01
Mat-connecting gel
with hook (set of 2)
Mat-connecting gel
(set of 2)
fixing a snap
punching
EPG-02
No need for holing or crimping
EPG-01
EPG-02
Common Specifications
Model No.
EDP No. 621481
EDP No. 621482
EPG-02
EPG-01
50×50mm
Size
104Ω or less
Conductivity
Operating environment
temperature and humidity
5°C to 30°C / 60% RH or less
Conductive polyurethane,
SUS, carbon film, PET
Material
Conductive polyurethane,
carbon film, PET
Grounding Cord
Connect to mat-connecting gel
with a single touch
Structure
Surface layer
(static electricity-diffusing rubber)
EPC-18/EPC-30
Backing
(conductive rubber)
Common Specifications
LG-100
SG-100
Light green
Green
Size
W1.0m×L10m×t2.0mm
W1.0m×L10m×t2.0mm
Conductivity
10 6≦R≦10 7Ω
10 6≦R≦10 7Ω
Weight
31kg/roll
31kg/roll
Material
NBR+SBR
NBR+SBR
Model No.
Color
EPC-30
EPC-18
EPC-30
Common Specifications
Model No.
Size
Resistance value
Accessories
EDP No. 621393
EDP No. 631394
EPC-18
EPG-02
max. length of 1.8m (max. length 0.5m)
max. length of 3.0m (max. length 1.5m)
1M Ω
Alligator clip
28
Ground Sensor ( Metal Band )
Grounding Sensor
Warns the operator with light and sound
when a grounding problem is detected
Designed to minimize dust generation,
this ground sensor can be used in clean rooms.
EPS-01EU/EPS-01G
EPS-03S/EPS-03M
45
18
46
80
(100)
EPS-03S:132, EPS-03M:167
28
*EPS-03S/EPS-03M ships with band
and sensor connected.
EPS-01EU EDP No. 621406
EPS-01G EDP No. 621407
Applications
Resistance value
EPS-01EU :
2 MΩ
EPS-01G :
Directive
For use in ESD protected areas and by device operators
EPA
For use in general work environments and by device operators
ANTI-METAL
ALLERGY
SUS316L
ALARM
BAD
GROUND
Washable
Battery
Charge
Alarm
The strap warns the operator with light and sound
when a grounding problem occurs.
A LOW BATTERY LED lights up when the remaining battery charge
falls to 20% or below.
A sensitivity adjustment knob lets you fine-tune the detection range.
Applications
Resistance value
For use in clean rooms, general work
environments, and by device operators
2 MΩ
ALARM
BAD
GROUND
Washable
Battery
Charge
Alarm
Directive
EPA
Low dust
Common Specifications
EPS-01
Size
Model No.
EPS-01G
Size
Strap length Approx. 180 mm
Resistance value
EPS-03S
EPS-03M
Strap length Approx. 132 mm
Strap length Approx. 167 mm
Resistance value
Body 1 MΩ/Grounding cord 1 MΩ
Material
Body 1 MΩ/Grounding cord 1 MΩ
Material
ABS, SUS
Accessories
EDP No. 621399
EDP No. 621398
The strap warns the operator with light and sound
when a grounding problem occurs.
A LOW BATTERY LED lights up when the remaining battery charge
falls to 20% or below.
A sensitivity adjustment knob lets you fine-tune the detection status.
Common Specifications
Model No.
EPS-03S
EPS-03M
ANTI-METAL
ALLERGY
SUS316L
Low dust
4.5
18
45
ABS, SUS
Accessories
Grounding cord 1.8m, Alligator clip, Test battery (already installed in CR1220)
Grounding cord 1.8m, Alligator clip
Anti-ESD Wrist Strap
Metal Band
Fits the wrist comfortably
and can be washed for repeated use
Complies with IEC 61340-5-1 for peace of mind
EPS-04B/EPS-04EU
EPS-02S/EPS-02M
20 sets Economy pack
Ultra Sonic Cleaner
(Available on the market)
No.EPS-02S:130 No.EPS-02M:160
EPS-02S
EPS-02M
Applications
Resistance value
Ideal for use in clean rooms and
in IT-related manufacturing
1 MΩ
ANTI-METAL
ALLERGY
SUS316L
Washable
37
Directive
Common Specifications
Size
Resistance value
Material
Accessories
29
EDP No. 621403
EDP No. 621401
Applications
Resistance value
For use in general work environments; ideal for use in IT-related
manufacturing settings with numerous temporary employees.
1 MΩ
ANTI-METAL
ALLERGY
SUS316L
Low dust
Stretchable band is easy to put on and take off.
Available in two sizes (small/medium).
Can be easily cleaned using an ultrasonic cleaner, (available on the market)
ensuring that the band is always clean and ready for use.
Model No.
EPS-04B
EPS-04EU
EDP No. 621409
EDP No. 621408
EPA
200
26
16
20
42
20.5
Washable
Directive
EPA
(EPS-04EU)
Low dust
Adjustable strap fits the wrist comfortably.
Safety-conscious design keeps the conductive area from
being exposed on the surface of the wrist strap.
Also Available as Easy Pack EPS-04EU (e-Box) .
Common Specifications
EPS-02S
EPS-02M
Strap length Approx. 130 mm
Strap length Approx. 160 mm
Grounding cord 1 MΩ
ABS, SUS
Grounding cord 1.8m, Alligator clip
Model No.
Size
Resistance value
Material
Accessories
EPS-04B
EPS-04EU (20 pcs/set)
Strap length Approx. 200 mm
Strap length Approx. 200 mm
Grounding cord 1 MΩ
PC, SUS
Grounding cord 1.8m, Alligator clip
Fan Type
Nozzle Type
Gun Type
Bar Type
EPA
Working Mat
Ion Parts
Cleaner
Clean Walker
Options
Electrostatic Field Meter
Electrostatic Field Meter
Compact measuring instrument for measuring
ionizer’s ion balance and product’s static potential
Visualizing invisible static electricity
Peak hold supports long-time measurements
Eye-01
Eye-02
73
NEW
115
width:25
EDP No. 621602
Measurement
Measurement
LCD display
Charge potential
Ion balance
Bar graph+ 3digits
One 9V
battery
ion balance
measurement
plate
Measuring
distance
25 mm
Out of
measuring
range alarm
Auto power
off
70
Peak hold
function
123
width:25
EDP No. 621603
Directive
Battery
level display
Anti-Drop
strap
Measurement
Measurement
LCD display
Charge potential
Ion balance
Bar graph+ 3digits
ion balance
measurement
plate
One 9V
battery
Measuring
distance
25 mm
Auto power
off
Out of
measuring
range alarm
Peak hold
function
Directive
Battery
level display
Easily establish measurement distance with focus ring LED.
Easily establish measurement distance with cross mark LED.
Backlight enhances visibility in dark places.
Color LCD clearly shows the polarity.
Color LCD clearly shows the polarity.
Mountable onto a tripod.
Focus Ring
Anti-Drop
strap
NG
25mm
OK
How to read : when two images
get together into one for the Scaling.
(Too Far)
(Too Close)
Charge Direction/Electrode Scale
Specifications
Specifications
Model No.
EYE-01
Model No.
EYE-02
Charge potential measurement
±0 to ±1.49 kV (LO range)/±1.0 to ±20.0 kV (HI range)
Charge potential measurement
±0 to ±1.50 kV (LO range)/±1.0 to ±20.0 kV (HI range)
Ion balance measurement
0 to ±200 V
Ion balance measurement
0 to ±200 V
Response time
within 1sec
Response time
within 1sec
Accuracy
±10%
Accuracy
±10%
Power
One 9V battery (006P)
Power
One 9V battery (006P)
Charged potential measurement distance
25mm±0.5mm
Charged potential measurement distance
25mm±0.5mm
L×W×Dmm
L115×W73×D25mm
L×W×Dmm
L123×W70×D25mm
Weight
140g/ion balance measurement plate 30g
Weight
170g/ion balance measurement plate 30g
Operating environment temperature and humidity 10°C to 40°C/60% RH or less
Ion balance measurement plate, Grounding cord,
alligator clip, Battery (006P), Soft case
Accessories
◆ Complies
Operating environment temperature and humidity 10°C to 50°C/80% RH or less
Ion balance measurement plate, Grounding cord,
alligator clip, Battery (006P), Soft case
Accessories
◆ Complies
with ISO 9000 traceability standards.
Calibration tables and certificates can be issued for this instrument. (Option)
with ISO 9000 traceability standards.
Calibration tables and certificates can be issued for this instrument. (Option)
Static Locator
Check for static charges and test the effectiveness of ionizers.
Provides a simple digital readout of static electricity
SDL-01
102
Provides a digital readout of the potential of
a charged object without making contact,
making it easy to measure invisible static electricity.
Convenient, lightweight design is extremely portable.
Comes with a soft storage case.
Low-power-consumption design can be used on 4 AA batteries.
LCD display
3 digits
4 AA
batteries
43
EDP No. 621382
Measurement
Charge potential
ion balance
measurement
plate
Measuring
distance
50 mm
Auto power
off
Out of
measuring
range alarm
Peak hold
function
Battery
level display
Drop
prevention
strap
51
Specifications
Model No.
SDL-01
Charge potential measurement
0 to ±19.9 kV (min. display increment of 0.1 kV)
Ion balance measurement
−
Response time
0.5 sec
Display range
Min. display increment of 0.1 kV
Supply voltage
6 VDC (4 AA batteries)
Device to charged object
50mm
L×W×Dmm
L102×W51×D43mm
Weight
170 g (including battery)
Operating environment temperature and humidity 0°C to 40°C/20% to 60%
Accessories
4 AA batteries, soft case
30
Why is VESSEL’s Clean Walker our customer’s top choice?
1
Non-peeling type adhesive mat
ed to pee
l
ne
!
off
No
There’s no need sacrifice cleanliness by limiting
the number of sheets peeled to save costs.
Clean Walker
2
Reliably catching dust
CW-900B
5mm thick
Capture dust off shoe soles
CW-900EZ
Self-adhesiveness of polyurethane resin is the
key.The thick mat flexibly contacts against
shoe treads and carefully catches dust
between them.
NEW
3mm thick Strong and tear resistant even
under heavy objects
Clean Walker
CW-T900
NEW
Inclined for easy trolley access
Conventional peel-off mats
3
Wash & dry to restore adhesiveness
Wet the surface with water, alcohol or diluted
household detergent, and the dirt will lift right
up. Wash and dry the mat well to restore the
original adhesiveness.
31
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Clean Waker Eazy
High elasticity.
Outstanding dust collection performance
Easy maintenance.
Just 3mm thickness
Applications
Material
For indoor use
Polyurethane
(especially in front of clean rooms)
CW-900EZ
ed to pee
l
ne
!
off
CW-900B
No
Clean Waker
Options
NEW
Eco-friendry product
Eco-friendry product
EDP No. 621485
EDP No. 621486
Washable
Applications
Material
For indoor use
Polyurethane,
non-woven textiles
Directive
(especially in front of clean rooms)
Washable
Directive
Non-woven textiles are sandwiched with a 3mm thickness to attain
a high strength
Resist tears even under the pressure of trolleys.
Take the mat out of the floor and wash it with water.Hang from
hook holes to dry off.
The 5mm high elasticity mat.
Powerfully catches dust from shoe soles.
Collected dust can be easily wiped off with a wet cloth.
Specifications
Specifications
Model No.
CW-900B
Model No.
CW-900EZ
Color
Blue
Color
Light purple
Size
W900mm×L500mm×t5mm
Size
W450mm×L500mm×t3mm
Conductivity
Insulator
Conductivity
Insulator
Weight
2.4kg
Weight
1.6 kg ( 2 pieces)
Material
Polyurethane
Material
Polyurethane, non-woven textiles
Clean Waker Tray
Inclined tray for easy trolley access
CW-T900
This dedicated tray is perfect for the Clean Walker size.
The inclination allows trolleys to pass over without catching.
Clean Walker mats can be removed with a little pull.
NEW
Directive
Specifications
Model No.
CW-T900
Color
Blue
Size
W1000mm×L600mm×t5mm
Conductivity
Insulator
Weight
2.45kg
Material
EPDM+SBR
32
Options and replacement parts
Electrode Needle Unit / Front Cover
Electrode Needle Unit
Electrode Needle Unit
Front cover w/needle electrode
EDP No. 806094
EDP No. 806053
EDP No.806127
Electrode Needle Plate
Front Cover with Integrated
Electrode Needles
Front cover w/needle electrode
EDP No. 806071
EDP No.806128
F-6H
SF-9H
Use with: F6CL-E, F6ST-E
F-120CH
Use with: SFQ9-E
F-12EH
EDP No. 806055
Use with: 3F-12-E
Use with: F120-E
CF-30H
F-120SCH
Use with:CF-30-E
Use with: F120S-E
Filter
Filter Set
Filter Set
SDJ-08F
SF-9F
SF-Q9F
F-120FS
F-120FF
CF-30F
EDP No. 806039
EDP No. 806052
EDP No. 621707
EDP No. 806123
EDP No. 806054
EDP No. 806072
Use with: F6CL-E, F6ST-E
Use with: SFQ9-E
Use with: SFQ9-E
Use with: F120-E,F120S-E
Use with:3F-12-E,F120-E,F120S-E
Use with: CF-30-E
AC Adapter
AD24-ITF6-E
AD24-IT-EX
AD24-ITCF
AD24-IT19
EDP No. 806096
EDP No. 806050
EDP No. 806074
EDP No. 806080
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.5A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.9A
Use with:
F6CL-E, F6ST-E
Use with: SFQ9-E,F120-E,
F120S-E
Use with: CF-30-E
Use with: 3F-12-E
For Gun / Nozzle Type
Standard Nozzle
N-2TN
EDP No. 806057
EDP No. 806085
Use with:G7R-E, N-2, N-1
Use with:G7R-E
Silent Nozzle
Straight Silent Nozzle
Shower Tube
N-2C6B
EDP No. 621706
Use with:N-2
(A combination of N-2TN)
Standard Nozzle
Flared Nozzle
N-2FN
EDP No. 806086
Use with:G7R-E, BBZ-E,
N-2, N-1
Corner Nozzle
N-2WN
BB-ZSN
N-1SN
N-1CN
EDP No. 806087
Use with:G7R-E,
BBZ-E, N-2, N-1
EDP No. 621708
Use with:G7R-E, BBZ,
N-2, N-1
EDP No. 806120
Use with:N-1
EDP No. 806121
Brush: 60 mm bristles
G-7B
EDP No. 806059
Use with:G7R-E
Electrode Needle Replacement
Screwdriver
G-7DR
EDP No. 806061
Use with:G7R-E, BBZ-E,
N-2, N-1
AC Adapter
Soft Brush: 60 mm bristles
Electrode Needle
N-1H
EDP No. 806062
EDP No. 806056
Use with:G7R-E, BBZ-E, N-2
EDP No. 806122
Use with:G7R-E
Speed Controller
G-7F
EDP No. 621373
EDP No. 621702
Use with:G7R-E, BBZ-E,
N-2, N-1
AC Adapter
Use with:G7R-E, BBZ-E,
N-2, N-1
AC Adapter
EDP No. 806067
EDP No. 806076
Use with: BBZ-E
EDP No. 806050
Relay Cable (10 m)
Use with:N-1
Microfilter
G-7SC
AD24-IT-EX
Use with: N-2, N-1
G-7EC5
G-7EC10
EDP No. 621703
EDP No. 621704
Use with: N-2,
Relay cables are used to connect
the G7R-E to its dedicated power
supply transformer (AD24-ITC-E).
Use this case when unstable
N-2 with Noise seen.
Use with: G7R-E,
(A combination of AD24-ITC)
Electrode Needle
G-7H
AD24-ITB-E
Relay Cable (5 m)
Use with:N-1
G-7SB
AD24-ITC-E
Use with: G-7RE
33
Tube-fitting Nozzle
G-7SN
Shieled Case
Filter eliminates at least 99% of particles with a
diameter of 0.01 μm or greater. Install a 1 μm to
10 μm air filter and mist separator on your air
compressor before using this item.
Fan Type
Nozzle Type
Gun Type
Bar Type
Ion Parts
Cleaner
EPA
Working Mat
Clean Walker
Options
For PAC-8
G7R-E Connection Cable
AC Adapter
G-7RC
(2.5m)
EDP No. 621705
AD24-ITC-E
EDP No. 806067
(A combination of G7R-E)
For C-series
Remote Control
Power Supply Cable
C-00H
RMC-01
EDP No. 806106
EDP No. 806104
EDP No. 621533
Electrode Needle Unit
CT-5
(A combination of AC Adapter)
AC Adapter
AC Adapter
AC Adapter
AD24-IT-EX
AD24-ITCF
AD24-IT19
EDP No. 806050
EDP No. 806074
EDP No. 806080
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.5A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.9A
Operation:One bar
Operation:Two bars
Operation:Three bars
For B-series
Electrode Needle Unit
B-00H
End Brackets
(set of 2 with set screws)
Middle Bracket
(with set screws)
EDP No. 806102
EDP No. 806103
B-EB
EDP No. 806101
Remote Control
RMC-01
B-MB
EDP No. 806104
Power Supply Cable
Branch Adapter
Power Supply Separator
EDP No. 621531
EDP No. 621532
B-SP2
CT-5
B-SP3
AC Adapter
EDP No. 621533
(A combination of AC Adapter)
AC Adapter
AC Adapter
AD24-IT-EX
AD24-ITCF
AD24-IT19
EDP No. 806050
EDP No. 806074
EDP No. 806080
I / P : AC100V~240V 0.4A
O/P : DC24V 0.75A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.5A
I / P : AC100V~240V 1.2A
O/P : DC24V 1.9A
Operation:One bar
Operation:Two bars
Operation:Three bars
Branch Box
Relay Cable (3 m )
Relay Cable (5 m)
EDP No. 621552
EDP No. 621553
EDP No. 621554
For SH-series
SH-SP2
SH-EC3
SH-EC5
For Ion Parts Cleaner
HEPA filter Cartridge
Medium-efficiency filter Cartridge
(Collects 99.7% of the 0.3µm Particles or larger)
Use with: IPC20-E, IPC40-E, IPC60-E
Use with: IPC20-E, IPC40-E, IPC60-E
Unwoven fan filter (5pc.)
IPC-A4F
EDP No. 806092
Use with: IPC-A4
Paper pack filter (6pc.)
IPC-A3F
Use with: IPC-A3
Adhesive gel sheet (1pc)
Electrode Needle (For N-1)
IPC-A4G
N-1H
EDP No. 806091
EDP No. 806122
Use with: IPC-A3, IPC-A4
(two sheets required per unit )
Use with: IPC-A3, IPC-A4
For EPS-01
Replacement Bands
(5-piece set /one with a dedicated tool )
EPB-01
EDP No. 621395
Use with: EPS-01, EPS-01G
34
VESSEL CO., INC
17-25, Fukae-kita 2-chome, higashinari-ku, Osaka 537-0001 JAPAN
Tel : +81(0)6 6976 7778 Fax : +81(0)6 6972 9441
●Product specifications, dimensions, pricing, and other information are
subject to change without notice.
●Static electricity erasing capability values given in this catalog were obtained in
our measurement environment.
Your results may differ depending on the operating environment.
Distributed by
VESSEL EUROPE
6, avenue du 1er Mai, ZAE Les Glaises, 91120 Palaiseau FRANCE
Tel : +33(0)1 69 19 17 42 Fax : +33(0)1 69 19 42 20
E-mail : [email protected]
Printed in Japan
URL : http://www.vessel.co.jp/english/
13031066.03