ksp-f05x Quick Setup instructions

KSP-F05X Five-Channel Dosing Pump
Version: AO
Quick Setup instructions of wireless routing mode
Kamoer Fluid Tech(shanghai)Co., Ltd
www.kamoer.com
Notice
1.The password mentioned below could change at your will. But
after change of password, please remember it, otherwise the
pump need to be back for factory reset.
2.In STA setting interface, please choose “Disable”when
obtaining the IP address automatically, or the pump need to be
back for factory reset.
3.IP address: After setting the IP address, please keep that in
mind.
4.Make sure the IP address you have set do not conflict with
other ones that connect the router, or the pump’s WIFI would
not be found. IF you can not find the pump’s WIFI, please check
to see if IP address conflict exists first.
5.Do not choose “quick setting”, otherwise it needs to ship back
to the factory for maintenance.
6.If the router need to bind MAC address, please make sure the
pump binds MAC address in advance.
Important Notice
Wireless routing mode is recommended
This instruction is for how to set the wireless routing mode, if you want to know more about
the pump’s other working mode, please check product manual.
1.Structure
Connect all the parts as the photo shown above
Note: Remote Antenna must be assembled properly, or WIFI of the pump may not be found
2.Mode
AP+STA mode: wireless routing mode ( it can be used as wireless hotspot or terminal connecting
to other wireless hotspot )
Picture 2-1-1 connection mode through router
2.1 Connection settings: use terminals that has the function of network connection to search for
network identity of five-channel dosing pump, then connect it.
2.2 Log in the router: Open your browser,input the 10.10.100.254 in the address bar,then enter
into the setting interface of the wireless router; initial user name is admin, password: admin ;
Following one is the picture when entering the interface successfully .
Picture 2-1-2 initial interface of the five-channel dosing pump
NOTE: Do not press “quick setup” button, or you can not find the pump’s WIFI, it need to
be back for factory reset.
2.3 STA mode setup:
Touch the “STA setting” in the left navigation bar, press “STA setting”,as shown in the
picture 2-3-1, in “mode selection”, select the “AP+STA”mode, press the “search” button, the
routing choose interface will appear like the picture 2-3-2
Picture 2-3-1 :STA mode setting interface of five-channel dosing pump
In the following routing interface, select the router you want to connect, then press “OK” button,
return to the STA internet setting mode, as shown in the picture 2-3-3
Picture 2-3-2: Routing choice interface
If the router need the password to connect, enter the router’s password in the picture “1”
In picture “2”, choose “Disable” in “obtaining IP address automatically”
In picture “3”, input the same IP address as the connecting router in “IP address”, make sure
the IP address has not been occupied, and remember it.
In picture “4”, input the subnet mask of connecting router in “subnet mask”
In picture “5”, input the gateway address of connecting router in “default gateway”
Press “save”, as the picture 2-3-4 shows, restart the router of five-channel dosing pump
Picture 2-3-3 STA mode internet setting
Picture 2-3-4: Restart the router of five-channel dosing pump
Picture 2-3-5: Interface of restarting successfully
2.4 test
Close the pump, then restart it, close the browser, then restart it, enter the same IP address
that set on the STA mode, as shown in the photo 2-3-3, the address here is 192.168.58.2, press the
“enter” to enter the address ;
If you can log in the router and enter into the setting interface again like the 2.2, it shows the
setting is OK;
3. Log in software
After successfully setting the wireless network, start the computer’s software, Logging in
interface in the picture 3-1-1
Picture 3-1-1: Logging in interface
Press “network setting” to set the network, enter the network seeting interface, as shown in the
picture 3-1-2
3-1-2: Network setting interface
In network setting interface, enter the IP address and port number, IP address is the same one
that have been set on the STA mode in picture 2-3-3, the port number is 8899; after successfully
setting, click “reconnect”, if the network connects successfully, a successful prompt will be shown,
as in the picture 3-1-3; After connecting successfully, press “OK”, in the logging in interface, enter
the password (initial password :345678), if the password is right, you can log in successful.
3-1-3: Successful prompt of connecting the network