A GUIDE TO LINE CLEANING USING PIPELINE™ ANY DRAUGHT BEER OUTLETS WITH STANDARD CLEANING EQUIPMENT SHOULD AIM TO CLEAN THEIR PIPES ON A WEEKLY BASIS. THIS REGULAR PROCESS WILL THEN PREVENT PRODUCT AND LINE CONTAMINATION FROM YEAST AND BIOFILM WHICH CAN DRAMATICALLY EFFECT THE PRODUCT QUALITY AND DISPENSE. AN INTRODUCTION TO PIPELINE™ The first, original, caustic free, line cleaner to use the colour change technology. Specifically designed to produce optimum cleaning results, this intelligent alkaline based beer line cleaner also offers improved health and safety and protection for your lines. Note: To maximise PIPELINE™ ’s effectiveness it is important you complete the following recommended process. Although PIPELINE™ is much safer than traditional chlorinated products, we still recommended using appropriate personal protective equipment, such as gloves, apron and goggles. Bartech - serving the hospitality industry BAR, CELLAR & KITCHEN SERVICES Site Survey, Consultation & Design Construction & Fitting Equipment Sales Installation After Sales Care Repairs Planned Maintenance CONTACT DETAILS Tel. 01794 324876 Email. [email protected] Web. www.bar-tech.co.uk Address. Unit 4 Gardeners Farm Business Park Sherfield English Lane Plaitford Hampshire SO51 6EJ A GUIDE TO LINE CLEANING USING PIPELINE™ CLEANING PROCEDURE USING PIPELINE™ Turn on cleaning gas Disconnect the beer Examine and thoroughly clean keg connectors Connect clean keg connectors to cleaning ring main Turn off beer coolers at the mains Bartech - serving the hospitality industry BAR, CELLAR & KITCHEN SERVICES Site Survey, Consultation & Design Construction & Fitting Equipment Sales Installation After Sales Care Repairs Planned Maintenance CONTACT DETAILS Tel. 01794 324876 Email. [email protected] Web. www.bar-tech.co.uk Address. Unit 4 Gardeners Farm Business Park Sherfield English Lane Plaitford Hampshire SO51 6EJ A GUIDE TO LINE CLEANING USING PIPELINE™ Measure out PIPELINE™ using a dilution rate of 1:40 Place PIPELINE™ into cleaning bottle and top up with cold water (a sample can be taken at this stage for comparison once cleaning complete) Connect the cleaning bottle to the cleaning ring main Bleed the fob detectors until the chamber is filled with purple solution. WAIT 5 MINUTES (while you wait, wipe down your cellar equipment and pipework with a diluted PIPELINE™ solution) After 5 minutes the cleaning fluid in a dirty chamber will change colour, bleed off discoloured solution. (you may have to repeat the last two processes until you are confident a stable purple fluid is achieved) Bartech - serving the hospitality industry BAR, CELLAR & KITCHEN SERVICES Site Survey, Consultation & Design Construction & Fitting Equipment Sales Installation After Sales Care Repairs Planned Maintenance CONTACT DETAILS Tel. 01794 324876 Email. [email protected] Web. www.bar-tech.co.uk Address. Unit 4 Gardeners Farm Business Park Sherfield English Lane Plaitford Hampshire SO51 6EJ A GUIDE TO LINE CLEANING USING PIPELINE™ NOW GO TO THE BAR Remove all sparklers and spouts for cleaning (remembering where the belong). Place in a pint glass or container with a dilute PIPELINE™ solution. Draw cleaning fluid through to all taps. It is likely the initially dispensed fluid will not be the same purple solution as the cellar, keep pouring until some form of purple solution is poured. WAIT 5 MINUTES (while you wait, wipe down the taps, drip trays and brackets with the dilute PIPELINE™ solution) After 5 minutes, pour off the dirty solution, in cases of extreme contamination, this can even be black! Keep pouring again until more purple solution is dispensed, try to pour off a full line full of fluid. WAIT 5 MINUTES Draw off more fluid, under normal circumstances the previous soaks should be sufficient to clean an average line and there should be no colour reaction at all. If, however, at this stage you find you are still getting colour reactions then continue with a further 5 minute soak. Once completed, if you continue to get reactions, contact our technical department on 01794 324876 to discuss and possibly book an intense professional clean. Bartech - serving the hospitality industry BAR, CELLAR & KITCHEN SERVICES Site Survey, Consultation & Design Construction & Fitting Equipment Sales Installation After Sales Care Repairs Planned Maintenance CONTACT DETAILS Tel. 01794 324876 Email. [email protected] Web. www.bar-tech.co.uk Address. Unit 4 Gardeners Farm Business Park Sherfield English Lane Plaitford Hampshire SO51 6EJ A GUIDE TO LINE CLEANING USING PIPELINE™ NOW GO BACK TO THE CELLAR Disconnect the cleaning bottle from the cleaning ring main Empty and rinse out any purple solution from the bottle (dilute PIPELINE™ can be run to drain) Refill the cleaning bottle with fresh water from the mains Reconnect the cleaning bottle to the cleaning ring main Bleed the fob detectors until filled with fresh water and no purple residue remains NOW GO BACK TO THE BAR Draw off fluid from all taps until no purple solution remains (as PIPELINE™ is coloured it allows to you to be completely sure that no cleaning solution is left in the line, as a result by using PIPELINE™ you will invariably save on reduced water wastage, time and money) Every box of PIPELINE™ is supplied with a pack of Neutral Litmus papers, these can be used to check that all traces of cleaning fluid have been removed from the line. To use, simply pull off some fluid from each tap and dip in the test paper, if any PIPELINE™ is present the paper will turn purple. If any trace is found, continue to flush the line with clean water then try the test again. Bartech - serving the hospitality industry BAR, CELLAR & KITCHEN SERVICES Site Survey, Consultation & Design Construction & Fitting Equipment Sales Installation After Sales Care Repairs Planned Maintenance CONTACT DETAILS Tel. 01794 324876 Email. [email protected] Web. www.bar-tech.co.uk Address. Unit 4 Gardeners Farm Business Park Sherfield English Lane Plaitford Hampshire SO51 6EJ A GUIDE TO LINE CLEANING USING PIPELINE™ NOW GO TO BACK TO THE CELLAR Disconnect the cleaning bottle from the cleaning ring main, empty and leave to dry. Switch off the cleaning gas Disconnect the keg connectors from the cleaning ring main and reconnect the kegs Bleed the fob detectors until beer has filled the chamber, ensure the ball is afloat by pressing the release button. Switch the coolers back on NOW GO BACK TO THE BAR Rinse out sparklers and replace on taps (making sure you have the right ones on the right taps) Pull through beer YOU NOW HAVE PERFECTLY CLEAN PRODUCTS FOR YOUR CUSTOMERS TO ENJOY For a video demonstration type the following address in your browser: http://www.youtube.com/watch?v=Gvq96wIls5s or click the link via our website. Bartech - serving the hospitality industry BAR, CELLAR & KITCHEN SERVICES Site Survey, Consultation & Design Construction & Fitting Equipment Sales Installation After Sales Care Repairs Planned Maintenance CONTACT DETAILS Tel. 01794 324876 Email. [email protected] Web. www.bar-tech.co.uk Address. Unit 4 Gardeners Farm Business Park Sherfield English Lane Plaitford Hampshire SO51 6EJ
© Copyright 2024